Quartz Lens Rod

  • October 2019
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Quartz Lens Rod as PDF for free.

More details

  • Words: 791
  • Pages: 2
MODULOC

®

®

REMOTE HIGH SPEED MODEL 9207 Hot Product Sensor (Background suppressed)

UTILISING OPTIC LEADS & SEPARATE LENSES Optic leads withstand 400°C Quartz Rod lens option withstands 1000°C Highly precise viewing angles Unique “combined” Air Purge & Cooling Interchangeable Remote Lenses 1°, 4°,7°, & 1⁄2° x 25° F.O.V. Quartz Rod Lens 1° F.O.V, 1000°C spec. (for under the line mounting)

Robust sensor purpose built to meet the higher speed detection requirements within the modern Steel Mill. Armoured optic lead allows remote lenses to be installed close to the process line in high ambients, whilst allowing the controller to be mounted in an accessible area. This sensor provides two types of output. In addition to the normal latched output indicating presence of hot product, a high speed 0.5 milli.sec pulsed output is initiated by the passing of the hot products leading edge. Both PNP transistor and reed relay outputs are provided according to the model selected.

Precise Slit F.O.V 0.5° x 25° lens

It is important to note that the pulsed output response time is virtually independent of the hot products temperature. In addition, background infrared is filtered.

(for above the line mounting)

n

An adjustable latching timer is provided on the pulse output to extenuate the leading edge signal and accommodate blackspots. A variety of remote lenses are available. For mounting above the line, the 0.5º x 25º lens is recommended for highest accuracy. Alternatively, for mounting close under the line, the quartz lens should be used. A supplementary analogue output assists in alignment off a small light source as well as providing early indication of lens contamination.

n

Edge Detection with 0.5 milli.sec response Supplementary analogue output

n

Background suppressed

n

n

Self check facility - 1 and 2 wire Pulsed and latching outputs

– BUILT TO LAST – MODULOC CONTROLS – BUILT TO LAST – MODULOC CONTROLS – BUILT TO LAST –

Type Coding Description From a selection of trip levels, lens varieties, electrical connections and other options, it is a straightforward procedure to identify by type coding the exact sensor required for a particular installation. Namely from the following options. Specifies Pulse Trip Detector

Identifies Options: Plug/Self–Check/Analogue Unit with self–check and plug connection Supplementary analogue output via plug connection Supplementary analogue output & self–check via plug connection

MD...4 MD...6 MD...7

Electrical Connection & Output Options

MD 92072-FR1A-97

Type 97B 97H

Specifies Optic Lead Length Code 1 to 8

Indicates optic length ( up to 8 metres)

110 VAC or 240 VAC 50/60 Hz ± 15% Driven

Leading Edge Output

N/Open PNP transistor ‘pulse’ output (500 mA). Switching speed 0.5 milliseconds to leading edge

Latch Outputs

N/Open PNP transistor output (500 mA protected) Switching speed 7 milliseconds to leading edge Single pole reed relay 1.5 Amp, 200 VDC/AC Switching speed 4 milliseconds on and off

Indicates Lens Requirement Lens Coding

24 VDC ± 10% Driven

F1 F2 Q1 F4 F7 7°

FR0 1

FR1

⁄2° x 5°

1

FIELD OF VIEW









Viewed area at 1 metre (mm’s)

20

40

20

70 120 10 x 130 10 x 250

⁄2° x 10°

FR2 1

Latching Timer

S2R

⁄2° x 25°

2 x 12°

10 x 500

40 x 200

Independent timer for both pulse outputs Adjustment range 0 - 100 milliseconds Pulse timer resets with each leading edge

Specifies Lens Mount Options

Refer to separate data sheet for information on Lens Mount Options

Code

Optic Lead Options Multi-strand glass optic cable encased within a tough flexible stainless sheath fabricated to withstand 400° C ambient

P

Air Purge Mount

C

Water Cooled Mount

A

Air Cooled and Purged Mount

1. Standard optic lead Type LG–*–AB used in conjunction with 1°, 4°, 7° and 2° x 12° F.O.V. lenses

D

Air Purged and Water Cooled Mount

2. Linearised fishtail optic Type LG–*–CB for use with 1/2° x 25° lens. Ensures high accuracy & sensitivity

These fittings may be ordered separately. See Remote Lenses Data Sheet.

Quartz Q1 Lens Rod

Precision FR Lens

Purged Shroud Nozzle shown

Series 9000 Remote Controller General Specifications Min. latched output trip level: 300°C Min. edge output trip level: 400°C Housing: Aluminium AL6. Rating: IP66, DIN, 89011. Coating: Oven bake blue paint. Weight: 1.7 Kilo 2 metre optic lead, excluding remote lens. Ambient limits: -20C to +65C. Electrical connection: Provided with 1.5 metre armoured 0.5mm core cable connected via IP65 plug/socket. Publication No: 39592/C

Refer to separate Data Sheet for dimensions of Remote Lenses.

Moduloc® Controls Limited Quadrant House, 235 High Street, London Colney, St. Albans, Herts. AL2 1HD Tel: 44 (0)1727 821313 (2 lines) Fax: 44 (0)1727 826804

The information presented herein is, to the best of our knowledge, accurate. However, please ensure that this information has not been amended or superseded