Direct-Operated Proportional DC Valve Series D1FT
Catalogue HY11-2500/UK
Characteristics The D1FT directional control valve of the nominal size NG6 (CETOP 3) is a proportional valve providing variable flow rates. This valve is used with integrated control electronics. Typical applications are soft switching via adjustable ramps for the reduction of hydraulic and mechanical shocks, and electrically adjustable flow rates / speeds for automating machine functions.
Technical features • Integrated control electronics with ramp adjustment • Progressive flow characteristics for sensitive adjustment of flow rate • Spring centred spool • Manual override
3
D1FT
D1FT.PMD CM
3-23
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Direct-Operated Proportional DC Valve Series D1FT
Catalogue HY11-2500/UK
Ordering Code
D
1
F
Nominal size NG06 / CETOP 3
3
Spool type
N Spool type
Flow control
DC valve
Code
T
DC valve
Style
(with integr. electronics)
7.5 15 20
E02C E02F E02H
7.5 15 20
0
Valve Electronic accessories design Seal Electronic Design NBR accessories series (different seal compound on request)
Flow [l/min] at ∆p 5bar per metering edge
E01C E01F E01H
0
Code
Voltage
F
Voltage input 0...±10V with reference output +10V / -10V
G
Current input 0...±20mA
Code
Style
QB = QA /2
B31F
15 / 7.5
C
QB = QA /2
B32F
15 / 7.5 E
K
Please order plugs separately. See chapter 3 accessories.
D1FT.PMD CM
3-24
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Direct-Operated Proportional DC Valve Series D1FT
Catalogue HY11-2500/UK
Technical Data General Design
Direct-operated DC Valve with onboard electronics
Actuation
Proportional solenoid
Size
NG6 (CETOP 3)
Mounting interface
DIN 24340 / ISO 4401 / CETOP RP121 / NFPA
Mounting position
Any
Ambient temperature
[°C]
-20...+60
Weight
[kg]
1.9
Hydraulic Max. operating pressure
[bar]
Fluid Fluid temperature
[°C]
Viscosity permitted
[mm2/s]
Viscosity recommended
[mm2/s]
Filtration Flow nominal
Ports P, A, B, T, X max. 350; Port Y max. 50 Hydraulic oil as per DIN 51524...535, other on request -20...+60 20...380 30...80 ISO 4406 (1999)
1)
Leakage at 100 bar
[l/min] [ml/min]
3
18/16/13 (acc. NAS 1683: 7)
20 <200
Static / Dynamic Step response at 100% step
[ms]
90
[%]
<8
[%]
100
Supply voltage/ripple
[V]
14.5 ... 30, ripple <5% eff.
Current consumption max.
[A]
2.8
Hysteresis Electrical characteristics Duty ratio Protection class
IP54
Input signal 2) Voltage Impedance Current Impedance
[V] [kOhm] [mA] [Ohm]
Differential input max.
[V]
Ramp
[s]
0...3
Pre-fusing
[A]
6.3 medium lag
10...0...-10, ripple <0.01% eff., surge free, 0...+10V P->A 100 20...0...-20, ripple <0.01% eff., surge free, 0...+20mA P->A 500 30 for terminal D and E against PE
EMC
EN 50081-1 / EN50082-2
Coil insulation class
F (155 °C)
Electrical connection Wiring min. Wiring lenght max.
6+PE acc. DIN 43563 [mm²] [m]
1)
Flow rate for different ∆p per control edge:
2)
Inverse polarity on request
7x1.0 (AWG 18) overall braid shield 50 Qx = QNom. ·
√
∆px ∆pNom.
D1FT.PMD CM
3-25
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Direct-Operated Proportional DC Valve Series D1FT
Catalogue HY11-2500/UK
Electronics Block diagram
3
Arrangement of the potentiometers
Central connector 6 + PE A
= supply (14.5...30 VDC)
B
= GND (0V)
C
= ref. +10 VDC
D
= input
E
= input
F
= ref. -10 VDC
(-10...+10 VDC) (-20...+20 mA)
G = PE
D1FT.PMD CM
3-26
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Catalogue HY11-2500/UK
Characteristic Curves
Direct-Operated Proportional DC Valve Series D1FT
Flow characteristics Spool code E* at ∆p 5bar per metering edge
3 Spool code B*
Flow limit 100% command signal
D1FT.PMD CM
3-27
Parker Hannifin GmbH & Co. KG Hydraulic Controls Division Kaarst, Germany
Direct-Operated Proportional DC Valve Series D1FT
Catalogue HY11-2500/UK
Dimensions
3
Surface finish
NBR BK375
4x M5x30 DIN 912 12.9
8.1 Nm
SK-D1FT-N30
D1FT.PMD CM
3-28