Produccion.docx

  • Uploaded by: Miey Vilca
  • 0
  • 0
  • June 2020
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Produccion.docx as PDF for free.

More details

  • Words: 1,146
  • Pages: 3
REGISTRO Y CONTROL DE CALIDAD PRODUCCION DE MINERAL (POR ZONA Y LABOR) CMASA - CONTROL DE CALIDAD - GEOLOGIA

(Nivel 4900)

SAN ANTONIO

ZONA

MANTO

LABOR

TURNO - FECHA

REFEREN. POTENCIA SECCION

NUMERO

MEDICION

MANTO

LABOR

SACOS

16/03/19 - B

MUESTRAS

PINTA

OBSERVACIONES

11

Tj -370-E

4

7

240

20

0

1

En entrada, dejando pilar.

11

Tj -370-W

16

6

310

30

0

0

En salida, presencia de Au.

11

Tj-658-E

3

4

230

8

0

0

Dejando pilar, en entrada.

11

Tj-658-W

14

4

250

12

1

0

S/N Con pendiente (Agua)

11

S/N-718-E

4

6a7

290

22

1

0

En salida,

11

S/N-718-W

Inclinado

9a4

350

14

0

0

Perf. Por mineral

12

Tj-603-E

14

3

220

0

0

0

Aparece manto al piso HI

12

Tj-603-W

25

3a4

250

9

0

0

Pasa la fall con 12 de despl. Al techo.

12

Tj-663-E

23

3a4

250

8

0

0

Sacando cara libre, falla NW

12

Tj-663-W

14

4

300

15

0

0

Chispas de Au.

12

S/N-723-E

18

3a1

210

8

1

0

Entrada

12

S/N-723-W

Tope

4

350

9

1

0

Sacando cara libre

TOTAL

RESPONSABLE

NOMBRE: DARWIN JHOEL

FIRMA: DJ - TITE

TITE

REGISTRO Y CONTROL DE CALIDAD PRODUCCION DE MINERAL (POR ZONA Y LABOR) CMASA - CONTROL DE CALIDAD - GEOLOGIA

(Nivel 4900)

SAN ANTONIO

ZONA

MANTO

LABOR

TURNO - FECHA

REFEREN. POTENCIA SECCION

NUMERO

MEDICION

MANTO

LABOR

SACOS

15/03/19 - B

MUESTRAS

PINTA

OBSERVACIONES

11

Tj -370-E

2

7

260

25

0

1

En entrada, dejando pilar.

11

Tj -370-W

17

6

300

24

1

1

En salida, presencia de Au.

11

Tj-658-E

5

6

300

20

1

0

En salida.

11

Tj-658-W

13

4

250

13

0

0

S/N Con pendiente (Agua)

11

S/N-718-E

6

6a7

300

25

0

0

En salida.

11

S/N-718-W

9

5

300

19

0

0

En salida.

12

Tj-603-E

14

1

220

0

0

0

Manto cloritizado sin mineral. F-SW

12

Tj-603-W

23

3a4

250

11

0

0

Falla con 12 de despl. Al techo.

12

Tj-663-E

23

3a4

250

14

1

0

Sacando cara libre, falla NW

12

Tj-663-W

15

4a5

300

12

0

0

Chispas de Au, roca dura.

12

S/N-723-E

17

3a1

220

0

0

0

Tiro soplado

12

S/N-723-W

Tope

5

370

17

0

0

Sacando cara libre

TOTAL

RESPONSABLE

NOMBRE: DARWIN JHOEL TITE

FIRMA: DJ - TITE

REGISTRO Y CONTROL DE CALIDAD PRODUCCION DE MINERAL (POR ZONA Y LABOR) CMASA - CONTROL DE CALIDAD - GEOLOGIA

(Nivel 4900)

SAN ANTONIO

ZONA

MANTO

LABOR

TURNO - FECHA

REFEREN. POTENCIA SECCION

NUMERO

MEDICION

MANTO

LABOR

SACOS

14/03/19 - B

MUESTRAS

PINTA

OBSERVACIONES

11

Tj -370-E

1

7

300

24

1

1

En entrada, dejando pilar.

11

Tj -370-W

19

6

290

22

0

1

En salida, presencia de Au.

11

Tj-658-E

6

6

300

22

0

0

En salida.

11

Tj-658-W

12

5

250

20

0

0

S/N Con pendiente (Agua)

11

S/N-718-E

7

6a7

300

26

1

0

En salida.

11

S/N-718-W

9

5

300

18

0

0

En salida.

12

Tj-603-E

13

0

220

0

0

0

Manto cloritizado sin mineral. F-SW

12

Tj-603-W

20

3a4

250

17

0

0

Falla con 12 de despl. Al techo.

12

Tj-663-E

23

3a4

250

14

0

0

Sacando cara libre, falla NW

12

Tj-663-W

15

4a5

300

12

0

0

Chispas de Au, roca dura.

12

S/N-723-E

17

3a1

240

9

0

0

Tiro soplado

12

S/N-723-W

Tope

3

250

4

1

0

Sacando cara libre

TOTAL

RESPONSABLE

NOMBRE: DARWIN JHOEL

FIRMA: DJ - TITE

TITE

REGISTRO Y CONTROL DE CALIDAD PRODUCCION DE MINERAL (POR ZONA Y LABOR) CMASA - CONTROL DE CALIDAD - GEOLOGIA

(Nivel 4900)

SAN ANTONIO

ZONA

MANTO

LABOR

TURNO - FECHA

REFEREN. POTENCIA SECCION

NUMERO

MEDICION

MANTO

LABOR

SACOS

17/03/19 - B

MUESTRAS

PINTA

OBSERVACIONES En entrada.

11

Tj -370-E

6

6

300

24

0

1

11

Tj -370-W

15

7

300

25

0

0

En salida.

11

Tj-658-E

5

4

230

8

0

0

Dejando pilar

11

Tj-658-W

16

4

250

12

0

0

S/N Con pendiente (Agua)

11

S/N-718-E

3.5

7

270

13

0

0

En salida, bordear pilar.

11

S/N-718-W

Inclinado

6

350

15

0

0

Perf. Por mineral

12

Tj-603-E

14

3

220

0

0

0

Aparece manto al piso HI

12

Tj-603-W

27

4

250

9

0

0

Pasa la falla, otra falla sin despl.

12

Tj-663-E

23

3

250

8

0

0

Sacando cara libre, falla NW

12

Tj-663-W

18

4

300

14

0

0

Chispas de Au.

12

S/N-723-E

Tope

3

250

10

0

0

Sacando cara libre.

12

S/N-723-W

Tope

4a5

340

9

0

0

Sacando cara libre

TOTAL

RESPONSABLE

NOMBRE: DARWIN JHOEL TITE

FIRMA: DJ - TITE

REGISTRO Y CONTROL DE CALIDAD PRODUCCION DE MINERAL (POR ZONA Y LABOR) CMASA - CONTROL DE CALIDAD - GEOLOGIA

(Nivel 4900)

SAN ANTONIO

ZONA

MANTO

LABOR

TURNO - FECHA

REFEREN. POTENCIA SECCION MEDICION

MANTO

LABOR

NUMERO SACOS

21/03/19 - B

MUESTRAS

PINTA

OBSERVACIONES

11

Tj -370-E

7

7

300

0

0

0

En entrada, cambio de ciclo.

11

Tj -370-W

10

8a9

300

30

1

0

Qz lechoso, pasa dique de 6.

11

Tj-658-E

9

4

260

25

1

0

Pasando pilar,

11

Tj-658-W

35

5

270

30

0

0

Entrando mas por zona de winche.

11

S/N-718-E

4

8 a6

260

29

0

0

Bordeando pilar por el inclinado.

11

S/N-718-W

7

5

270

24

1

0

Dejando pilar, por el winche.

12

Tj-603-E

4

3a4

280

4

0

0

Cambio de ciclo, No se trabajó.

12

Tj-603-W

30

6

260

23

0

0

Falla desplaza manto al techo.

12

Tj-663-E

18

5a4

320

18

1

0

Tj, en retorno.

12

Tj-663-W

11

3a4

300

9

0

0

Dique de 5 con Ag.

192

4

12

S/N-723-E

12

S/N-723-W

TOTAL

RESPONSABLE

NOMBRE: DARWIN JHOEL

FIRMA: DJ - TITE

TITE

REGISTRO Y CONTROL DE CALIDAD PRODUCCION DE MINERAL (POR ZONA Y LABOR) CMASA - CONTROL DE CALIDAD - GEOLOGIA

( Nivel 4955)

SANTA ANA

ZONA

MANTO

LABOR

12

TJ-620-E

12

TJ-620-W

TURNO - FECHA

REFEREN. POTENCIA SECCION

MUESTRAS

PINTA

37

1

0

Manto separado

3

0

0

Minerala recuperado.

MEDICION

MANTO

LABOR

SACOS

10.6

6a3

240

4

210

OBSERVACIONES

10

TJ-990-E

16

6a7

215

20

1

0

Entrando en negativo.

10

TJ-990-W

3.3

3a4

200

0

0

0

F. sin relleno, sin despl.

4

Tj -730-E

4

Tj-730-W

4

GAL-200-E

Tope

8 a 10

220

18

0

0

F. con relleno y oxidos.

6

GAL- 220(-)

4

5a6

240

22

0

0

Negativo hacia el W.

6

GAL-220(+)

OSO

GAL-830-E

OSO

S/N-830-E

OSO

S/N-830-W

No trabajó No trabajó

No trabajó No trabajó 14

1a3

220

965

POD.

ZAR-915

RITTY

ZAR-PTA

13

0

1

Pasa la Falla, a 1 m. No trabajó

16

TOTAL

PLANTA

NUMERO

21/03/19 - B

129 152

BALCON-III 281

RESPONSABLE

2

NOMBRE: DARWIN TITE

FIRMA: DJ

More Documents from "Miey Vilca"

Produccion.docx
June 2020 2
December 2019 12
2. Resumen Ejecutivo.docx
December 2019 17
Pma Desmontaje .docx
November 2019 24