NT 6 Contrast scanners Dimensional drawing 56
■
■
1
3
10 13
28
2
6 M5
■
LED light source with two switchselectable spectral ranges Lens position selectable Light- or dark-switching selectable Rapid response times
28
M5
■
21
Contrast scanners
9
30.4
25
15.4
40
5
64
Scanning distance 9 mm
4 3
3
52
80
3
Blind screw can be replaced by Item 2 Lens can be replaced by Item 1 3 M 5 threaded mounting hole, 5.5 mm deep 4 Function signal indicator 5 Cover for adjuster 6 4-pin, M 12 plug or 2m cable with T3104/1 plug or 2m cable 7 Control for switching threshold 8 Switch for operating mode X Light-switching ● Dark-switching
Adjustments possible NT 6-03022 NT 6-04018 NT 6-13022 NT 6-03012 NT 6-04022 NT 6-03018
1 2
NT 6-13012 NT 6-04012
7
8 J
J
Connection types
C
U
V
Accessories
page
Cable receptacles Lens
496 556
412
SENSICK CATALOGUE
NT 6-03022 NT 6-13022 NT 6-04022
NT 6-03018 NT 6-04018
NT 6-03012
6 x 0.34 mm2
4-pin, M 12
cable + plug
L+
brn
1
gra
Q
blk
4
blu
M
blu
3
blk
PE
wht
2
grn
NC
gra
5
yel
QA
red
NT 6-13012 NT 6-04012
L+
2
Q
1
M
6
PE QA
L+ Q M PE
4 3
NC QA
NT 6 Technical data Scanning distance from front edge of lens Light type/light spot dimension
NT 6-
03012 03022 03018 13012 13022 04012 04022 04018
9 mm ± 2 mm Green/1.5 x 5 mm Red/1.5 x 4 mm
Light source 1), light type Light spot direction
LED, red, green selectable Longitudinal Transverse
Supply voltage VS Ripple 3) Current consumption 4) Switching outputs
Output current lA max. Response time 5) Max. switching frequency 6)
10 . . . 30 V DC 2) <5V < 80 mA Light-/dark-switching, selectable B: HIGH = VS – < 2 V/LOW = < 2 V PNP: HIGH = VS – < 2 V/LOW = 0 V 200 mA 50 µs To 10 kHz
Analogue output QA
0.15 . . . 6 V
Connection types
Cable 7) with T 3104/1 plug Cable 7) without plug Plug
VDE protection class 8) Enclosure rating Circuit protection 9)
V
Ambient temperature TA Shock load Weight Housing material
Operation – 10 °C . . . + 50 °C Storage – 25 °C . . . + 75 °C To IEC 68 Approx. 540 g Cast metal
1) Average service life 100,000 h at TA = + 25 °C 2) Limit values
3) May not exceed or fall short of VS tolerances 4) Without load
IP 67 A, B, C
9) A = VS connections reverse-polarity protected B = Outputs Q and QA short-circuit protected C = Interference pulse suppression
5) Signal transit time with resistive load 6) With light/dark ratio 1:1 7) Do not bend below 0 °C 8) Reference voltage 50 V DC
Order information
Scanning distance 120
100
80 1
Relative sensitivity in %
60
Type
Part no.
NT 6-03012
1 005 821
NT 6-03022 NT 6-03018
1 005 822 1 006 367
NT 6-13012
1 005 823
NT 6-13022 NT 6-04012
1 005 824 1 006 474
NT 6-04022
1 006 475
NT 6-04018
1 007 478