NT 6 Contrast scanners Dimensional drawing 56





1

3

10 13

28

2

6 M5



LED light source with two switchselectable spectral ranges Lens position selectable Light- or dark-switching selectable Rapid response times

28

M5



21

Contrast scanners

9

30.4

25

15.4

40

5

64

Scanning distance 9 mm

4 3

3

52

80

3

Blind screw can be replaced by Item 2 Lens can be replaced by Item 1 3 M 5 threaded mounting hole, 5.5 mm deep 4 Function signal indicator 5 Cover for adjuster 6 4-pin, M 12 plug or 2m cable with T3104/1 plug or 2m cable 7 Control for switching threshold 8 Switch for operating mode X Light-switching ● Dark-switching

Adjustments possible NT 6-03022 NT 6-04018 NT 6-13022 NT 6-03012 NT 6-04022 NT 6-03018

1 2

NT 6-13012 NT 6-04012

7

8 J

J

Connection types

C

U

V

Accessories

page

Cable receptacles Lens

496 556

412

SENSICK CATALOGUE

NT 6-03022 NT 6-13022 NT 6-04022

NT 6-03018 NT 6-04018

NT 6-03012

6 x 0.34 mm2

4-pin, M 12

cable + plug

L+

brn

1

gra

Q

blk

4

blu

M

blu

3

blk

PE

wht

2

grn

NC

gra

5

yel

QA

red

NT 6-13012 NT 6-04012

L+

2

Q

1

M

6

PE QA

L+ Q M PE

4 3

NC QA

NT 6 Technical data Scanning distance from front edge of lens Light type/light spot dimension

NT 6-

03012 03022 03018 13012 13022 04012 04022 04018

9 mm ± 2 mm Green/1.5 x 5 mm Red/1.5 x 4 mm

Light source 1), light type Light spot direction

LED, red, green selectable Longitudinal Transverse

Supply voltage VS Ripple 3) Current consumption 4) Switching outputs

Output current lA max. Response time 5) Max. switching frequency 6)

10 . . . 30 V DC 2) <5V < 80 mA Light-/dark-switching, selectable B: HIGH = VS – < 2 V/LOW = < 2 V PNP: HIGH = VS – < 2 V/LOW = 0 V 200 mA 50 µs To 10 kHz

Analogue output QA

0.15 . . . 6 V

Connection types

Cable 7) with T 3104/1 plug Cable 7) without plug Plug

VDE protection class 8) Enclosure rating Circuit protection 9)

V

Ambient temperature TA Shock load Weight Housing material

Operation – 10 °C . . . + 50 °C Storage – 25 °C . . . + 75 °C To IEC 68 Approx. 540 g Cast metal

1) Average service life 100,000 h at TA = + 25 °C 2) Limit values

3) May not exceed or fall short of VS tolerances 4) Without load

IP 67 A, B, C

9) A = VS connections reverse-polarity protected B = Outputs Q and QA short-circuit protected C = Interference pulse suppression

5) Signal transit time with resistive load 6) With light/dark ratio 1:1 7) Do not bend below 0 °C 8) Reference voltage 50 V DC

Order information

Scanning distance 120

100

80 1

Relative sensitivity in %

60

Type

Part no.

NT 6-03012

1 005 821

NT 6-03022 NT 6-03018

1 005 822 1 006 367

NT 6-13012

1 005 823

NT 6-13022 NT 6-04012

1 005 824 1 006 474

NT 6-04022

1 006 475

NT 6-04018

1 007 478

40

20

0

(mm)

5

10

1 Scanning distance

15

20

25

30 9 mm

SENSICK CATALOGUE