The Frater MCB protects wires and cables automatically against overload and short-circuits in domestic, commercial and industrial installations. In systems where proper earthing is provided the MCB provides additional protection by instantaneous interruption of the fault current, in case of faults, thereby eliminating the possibility of excessive touch voltages. Range : The Frater 6KA MCBis available in a comprehensive range from 0.5 to 100A in 1,2,3 & 4 pole versions. Standards : This range of MCB's conforms to the latest National and International standards - IEC60898. Modular Design: The MCBs are most compact with mounting depths up to 55mm and widths in multiples of 18mm and are part of the modular N system. They are hence totally compatible in modular width size to our range of RCCBs and can be enclosed in our low-profile DBs. Frater MCBs have contact tips made of special silver alloys ensuring higher life and maximum safely against contact welding. These contacts have low contact resistance resulting in reduced voltage drop and a very low watt loss leading to energy savings.

6KA 10KA

Specification : IEC 60898-95 Short Circuit Breaking Capacity : 6 kA & 10 kA Typ e Classification : B & C Rated Voltage : 240 / 415 V: 50 HZ 0

Ref. Ambient Temperature : 50 C

100A MCB

Causes of Short circuit and overloads I-ON I-ON

240/415v~ ON

3

OFF

125A Isolator

A

240/415v~ ON

3

OFF

D C M C B U P TO 1 0 0 A M P S FRATER MCB for DC application have been developed by inhouse R & D facilities of the company to meet the stringent market requirements of DC circuits.

AVAILABILITY : DC MCBs are available in SP & D P configuration form 0.5 Amp to 100Amp in various voltages such as 12V, 24V, 48V, 60V, 110V, & 220Volts.

FEATURES: Dual tripping system-Overload through precisely calibrated bimetal and short circuit through electromagnetic coil. DC MCB incorporates a built in permanent magnet, which directs the arc into the arc quenching chamber. Free from nuisance tripping caused by vibrations. Time constant < 5ms. DC MCB offers a unique feature of knob assuming mid trip position in the event of fault. This enables clear visual indication of the faulty circuit. Housing of DC MCB is made up of fire retardant, anti-tracking and non-hygroscopic injection moulded thermoplastic polyester. Contacts are made up of silver inlaid copper, which ensure low resistance and longer life of circuit breaker.

1 0 0 A M P M C B & 1 2 5 A M P I S O L AT O R 100 Amp MCB & 125 Amp ISOLATOR ha s been designed keeping in mind the customer needs. The features are as under : Conforms to IEC 898-95. We have maintained standard thickness of 17.5mm, similar to lower rating of MCB (0.5 A to 63 A) to facilitate easy mounting in any Distribution Box without requiring any extra space or speical Distribution Boards. Box type terminal has been designed for easy termination of cable up to 50 mm2. Heavy duty screws have been provided for better tightening of contacts. Heavy duty ETP co pper terminals and extra thick silver inlaid contacts ensures low temperature rise and low watt loss.

Internal View of MCB Box terminal

:

Din clip

CONFORMS TO LATEST STANDARD Mid trip bar Arc chamber Hammer action solenoid

The

SALIENT FEA TURES

Arc runner Trip latch Fixed contact Moving contact

Thermo metal

FRATER MCB conform to the latest s tanda IEC Pub 898 (1995) in selected ratings. CE MARKING Fulfills the requirement of global standards.

ENERGY SAVING: The low power loss as stipulated in the IEC 898/95, has been taken care of in designing the FRATER MCB. low power loss figu res of FRATER MCB contributes significantly to the energy saving.

DIN RAIL MOUNTING: FRATER MCB's can be mounted on standard 35mm DIN Rail by snap action. No time wastage in installing and replacing the MCB. SHOCK PROOF: Finger and hand touch safe.

Box terminal Bimetal carrier

Tes ted as per IEC Pub 898 (1995) & IEC-6 0898-1, 2002 protection against electric shock.

Salient Features cont... HOUSING: The housing of FRATER MCB is injection moulded from special grade PBT as per international specifications. The housing and other moulded components are fire retardant, anti-tracking and non hygroscopic. The housing can with stand high temperature and is impact resistant.

CONTACTS: Contacts are made of special silver inlaid into copper strip, ensuring higher life and maximum safety against contact welding and erosion. These contacts have low contact resistance resulting in reduced watt loss.

CURRENT LIMITING ACTION: The high speed current limiting action ensures that the MCB operate before the full prospective fault current is allowed to develop. Under fault conditions, damage can be sustained to the installation and as sociated equipment due to the amount of energy that passes before the current is completely interrupted. The total energy Let through depends on th e value of current and the time for which it flows, and is denoted by the symbol I 2t. The high speed current limiting action of FRATER MCB ensures that the energy let through and any subsequent damage is minimized. This reduced LET TH ROUGH ENERGY (Class 3 as per BS EN 60898) assists greatly with both back-up and discrimination considerations.

OPERATING MECHANISM: FRATER MCB have a quick make & break Tri p Free Mechanism. In the even t of an over current or short circuit the MCB automatically interrupts all poles even if the MCB toggle is held in ON position, the handle always indicates the correct contact position.

MODERATE OVERLOAD CONDITION: Detection of moderate over load conditions is achieved by the use of a Bimetal Overload Relay, which deflects in response to the current passing through it. The Bimetal Relay moves against the trip bar releasing the trip mechanism.

Rated Current

SHORT CIRCUIT CONDITIONS: When the current flowing through the MCB reaches a predetermined level, the solenoid in Magnetic Coil directly pulls in the plunger, which release the trip mechanism.

PERFECT CONNECTIONS: The design of terminals makes the wiring easier. Combination box type terminals with combination head screws on both sides with deep serrations ensures sparkless and firm connections. The bi-connection facility simplifies connection in various application areas.

LOW WATT LOSS: FRATER MCBs have been designed to minimize energy loss through unique contact configuration & reduction of hot spots. Watt loss per pole in FRATER MCB is far lower than that specified in IEC : 60898

6 10 16 25 32 40 50 80

< In < In < In < In < In < In < In < In

< 10 < 16 < 25 < 32 < 40 < 50 < 63 < 100

MID-TRIP POSITION: The Mid-Trip Position of the knob is clear indication of the fault. Faulty circuit id entification becomes easy.

Max. allowable Watt loss per pole as per IEC 60898-95

3.0 3.5 4.5 6.0 7.5 9.0 13.0 Consideration

TECHNO MCB Max. Watt Loss Per Pole

0 .75 2 .0 2 .6 3 .3 4 .0 4 .6 5 .2 9 .2

TRIPPING CHARACTERISTICS: FRATER MCB 0.5A-100

Type Non Tripping Tripping Magnetic Tripping Current Cuttent Min. Max. Min. (1 Hr.) Max.(1hr.) B

1.13 In

1.45 In

3 In

5 In

0.5A-100A C

1.13 In

1.45 In

5 In

10 In

RECOMMENDED APPLICATIONS:

C 32

240/415

v~ ON

3

B TYPE: fo r protection of Resistive load such as bulb, heater etc. C TYPE: fo r protection of Inductive load such as motor, air conditioner etc.

OFF

MCB - TPN 100 AMP

AUX I L I A RY S W I T C H FRATER MCB with Auxiliary Switch Salient Features cont...

POTENTIAL FREE DIN CLIP: The all insulated

Auxiliary switch can be supplied factory fitted with any MCB (SP, SPN, DP, TP, TPN, FP) to give indication of 'ON' or 'OFF' position of MCB

DIN clip ensures electrical safety and high mechanical strength.

WORKING PRINCIPLE: FRATER MCB is a high fault capacity, thermal-magnetic type of breaker. It protects ag ainst overload and short circuit. Over load protection is achieved with a thermal bi-metal strip which gets heated in case of overload and in turn pushes the trip latch which releases the contacts and the operating knob is switched to Mid Tri p Position clearly indicating the fault. In case of short circuit the high fault cu rrent energizes the magnetic coil resulting in plunger striking the trip lever which ensures immediate release of tripping mechanism and the operating knob is switched to Mid Trip Position.

I-ON

C 32 240/415v~ ON

3

OFF

I-ON

T E C H N I C A L DATA FUNCTION:

Specifications

: IEC Pub 60898

The auxiliary switch is used for remote indication of the circuit condition (ON/OFF) of the MCB. Al l the connecting terminals are easily accessible from the top position. The auxiliary switch is connected to the tripping mechanism of MCB and operates along with MCB. That it is switched ON and OFF together with the MCB through the connector. It is available in factory fitted module. This can be used in following outgoing combination modes depending upon user requirement.

Number of Poles

: 1, 1+N,2,3,3+N & 4

Configuration

Combination of Terminals to be used 21-22, 11-14 21-22, 11-12, 14 21-22, 11-12

N.C. & N.O. N.C. & Changeover N.C. & N.C.

WIRING DIAGRAM

22 Outgoing

12 14

21

11 Incoming

Tri pping Characteristic & Rated

: B characteristics - 0.5A to 100 A

Currents (In)

: C characteristics - 0.5A to 100A

Rated breaking capacity (Icn)

: 10,000 A

Energy Limiting Class

: Class 3 as per BS EN 60898

Rated Voltages (Ue) Single Pole Multi Pole

: 240 / 415 VAC : 415 VAC

Insulation Voltage (Ui)

: 500V

Rated Frequencies

: 50/60 Hz

Impulse withstand voltage (Uimp)

: 4 KV (1.2 µ)

Impulse power frequency voltage

: 2 KV (50 Hz)

Housing material

: Polybutylene T erephthalate in Grey colour

Degree of Protection

: IP 20 as per IEC 60529

Mounting Position

: Any position

Mounting

: Quick snap to mounting rails, 35 mm

Connecting Terminals Suitable

: Combination box terminals on incoming and outgoing sides. for single-core, stranded and flexible conductors upto 25 sq mm, combination crosshead screw, max. tightening torque 2 Nm

Electrical Service Life

: Min. 30,000 make/break operations

Ambient T emperature

: Tmax : 55¼ C Tmin.:(-) 25¼C

Impact Resistance

: 3g, At least 2 impacts duration 13 ms

TECHNICAL DATA Configuration Rated Voltage Rated Current Conductor Crossection Tightening Torque

Combination of Terminals to be used 220 V Ac / 110 V Dc 6A AC / 1 A DC Upto 1 mm2 1Nm

DC MCB Specifications

: IEC 60898-2-2002

No. of Poles

: Single pole, Double pole

Rated Current

: 0.5A to 100A

Rated Voltage

: 220V DC

Rated short circuit breaking capacity : 1kA

ISOLATOR

Insulation Voltage

: 500 V

Specifications

: IEC-60947-3, 1999

Degree of protection

: IP 20 as per IS : 13947 / IEC-60529

Number of Poles

: SP, DP, TP & FP

Mounting Position

: Any position

Utilization Category

: AC23A

Connecting T

Rated Voltage

: 240 / 415 V AC

Electrical Service Life

: 10000 Cycles

Rated Currents

: 16 to 125 Amp.

Impact Resistance

: 3g, Atleast 2 impacts duration 13 ms.

TRIPPING CHARA CTERISTICS CURVES

Tripping Characterstics Curve Type B & C

Reference Calibration Temp. 300C

Tripping Characterstics Curve DC MCB Type B & C

FRATER MCB Vs Zero Point Extinguishing MCB

Reference Calibration Temp. 300C

FRATER

DIMENSIONS

Temperature Compensation Graph

65

Correction Factor Reference Calibration Temp. 300C

82

Single Pole MCB with Auxiliary Switch

All Dimensions are in mm

FRATER 6KA MCB

Selection and Type References. Single Pole + Neutral

Single Pole

Triple Pole

Double Pole

Four Pole

I-ON

I-ON

I-ON

I-ON

I-ON

I-ON

I-ON

I-ON

I-ON

I-ON

I-ON

C 32

240/415v~ ON

3

OFF

Rating (A)

Type Ref. No.

Type Ref. No.

Type Ref. No.

Type Ref. No.

Type Ref. No.

0.5 1 2 4 6 10 16 20 25 32 40 50 63 80 100

FRTSP00605 FRTSP00601 FRTSP00602 FRTSP00604 FRTSP00606 FRTSP00610 FRTSP00616 FRTSP00620 FRTSP00625 FRTSP00632 FRTSP00640 FRTSP00650 FRTSP00663 FRTSP00680 FRTSP06100

FRTSPN0606 FRTSPN0610 FRTSPN0616 FRTSPN0620 FRTSPN0625 FRTSPN0632 FRTSPN0640 FRTSPN0650 FRTSPN0663 FRTSPN0680 FRTSPN6100

FRTDP00605 FRTDP00601 FRTDP00602 FRTDP00604 FRTDP00606 FRTDP00610 FRTDP00616 FRTDP00620 FRTDP00625 FRTDP00632 FRTDP00640 FRTDP00650 FRTDP00663 FRTDP00680 FRTDP06100

FRTTP00605 FRTTP00601 FRTTP00602 FRTTP00604 FRTTP00606 FRTTP00610 FRTTP00616 FRTTP00620 FRTTP00625 FRTTP00632 FRTTP00640 FRTTP00650 FRTTP00663 FRTTP00680 FRTTP06100

FRTFP00605 FRTFP00601 FRTFP00602 FRTFP00604 FRTFP00606 FRTFP00610 FRTFP00616 FRTFP00620 FRTFP00625 FRTFP00632 FRTFP00640 FRTFP00650 FRTFP00663 FRTFP00680 FRTFP06100

Isolator Single Pole

Triple Pole

Double Pole

Four Pole

I-ON I-ON

I-ON

I-ON

I-ON

ISOLATOR

ISOLATOR

ISOLATOR

ISOLATOR

Rating (A)

Type Ref. No.

Type Ref. No.

Type Ref. No.

Type Ref. No.

16 25 32 40 63 100

FRTSPISO16 FRTSPISO25 FRTSPISO32 FRTSPISO40 FRTSPISO63 FRTSPISO100

FRTDPISO16 FRTDPISO25 FRTDPISO32 FRTDPISO40 FRTDPISO63 FRTDPISO100

FRTTPISO16 FRTTPISO25 FRTTPISO32 FRTTPISO40 FRTTPISO63 FRTTPISO100

FRTFPISO16 FRTFPISO25 FRTFPISO32 FRTFPISO40 FRTFPISO63 FRTFPISO100

SELECTION AND TYPE REFERENCES.

10KA MCB Rating

Type Ref. No.

Type Ref. No.

0.5

FRTSP01005

-

1

FRTSP01001

-

2

FRTSP01002

-

4

FRTSP01004

-

6

FRTSP01006

FRTSPN1006

10

FRTSP01010

FRTSPN1010

16

FRTSP01016

FRTSPN1016

20

FRTSP01020

FRTSPN1020

25

FRTSP01025

FRTSPN1025

32

FRTSP01032

FRTSPN1032

40

FRTSP01040

FRTSPN1040

50

FRTSP01050

FRTSPN1050

63

FRTSP01063

FRTSPN1063

80

FRTSP01080

FRTSPN1080

100

FRTSP10100

FRTSPN10100

(A)

Single Pole + Neutral

Single Pole

I-ON

1 0 00 0 3

I-ON

10 0 0 0 3

SELECTION AND TYPE REFERENCES.

10KA MCB Triple Pole

Double Pole

Type Ref. No.

Type Ref. No.

Type Ref. No.

0.5

FRTDP01005

FRTTP01005

FRTFP01005

1

FRTDP01001

FRTTP01001

FRTFP01001

2

FRTDP01002

FRTTP01002

FRTFP01002

4

FRTDP01004

FRTTP01004

FRTFP01004

6

FRTDP01006

FRTTP01006

FRTFP01006

10

FRTDP01010

FRTTP01010

FRTFP01010

16

FRTDP01016

FRTTP01016

FRTFP01016

20

FRTDP01020

FRTTP01020

FRTFP01020

25

FRTDP01025

FRTTP01025

FRTFP01025

32

FRTDP01032

FRTTP01032

FRTFP01032

40

FRTDP01040

FRTTP01040

FRTFP01040

50

FRTDP01050

FRTTP01050

FRTFP01050

63

FRTDP01063

FRTTP01063

FRTFP01063

80

FRTDP01080

FRTTP01080

FRTFP01080

100

FRTDP10100

FRTTP10100

FRTFP10100

Rating (A)

I-ON

I-ON

I-ON

I-ON

1 00 0 0 3

1 00 0 0 3

Four Pole

I-ON

I-ON I-ON I-ON I-ON

MCB Changeover Switch Two way centre off l Conforms to IEC : 60947-3 l Choice of 2 Pole & 4 Pole versions l Front operation with three stable positions I-O-II l Isolator at middle position l DIN Rail Mounting facility

Technical Specification Standard Conformity No. of Poles (Execution) Rated Current (In) Rated voltage (Ue) Rated Frequency Rated insulation voltage Dielectric Strength Rated impulse voltage Utilization Category Ambient Temp. Mechanical life Electrical life Mounting Mounting Position Terminal Capacity Weight Double Pole Four Pole

Connection Diagrams / Technical Marking Two Pole

"I" "II" *

Four Pole

Incoming terminals terminals (main supply) Incoming terminals terminals (standby (standby supply) Outgoing terminals terminals (to load) Mid position of knob is 'OFF' position

2&6 4&8 1&5

"I" "II" *

Incoming terminals terminals (main supply) Incoming terminals terminals (standby (standby supply) Outgoing terminals terminals (to load) Mid position of knob is 'OFF' position

2, 6, 10 & 14 4, 8, 12 & 16 1, 5, 9 & 13

: : A : V : Hz: V : kV : kV : : ºC : : : : : mm2 : gms : gms :

IEC 60947 - 3 / 2 Pole, 4 Pole 25A, 40A, 63A 240 AC / 415 AC 50 660 2.5 6 AC 21 A -5 to +55 10000 operations 10000 operations Standard (35 x 7.5) mm - DIN Rail Vertical / Horizontal 25 134 268

Dimension (in mm)

Introduction From large buildings to private homes, from industries to hospitals, electricity is essential. The extensive use of electricity in our daily life has become so common that we tend to forget that careless use of electricity can be hazardous. Every year, a large number of people are victims of accidents caused by negligent use of electricity, and a large number of industrial & domestic fires are attributed to "electrical faults". FRATER has introduced state-of-the-art FRATER RCCB model FI7 made in Europe, which is capable of detecting earth leakage current as soon as they appear and isolate the supply system.

L1 L2 L3 N

Operational Principle

2 Pole

T

Load Earth

Wiring Scheme for RCCB 4 Pole

FRATER RCCB is a current operated device and is independent of line voltage conditions. This means that they provide protection even when there is voltage dip or the neutral conductor is interrupted. In a healthy system the vector sum of all currrents in phase and neutral is equal to zero. The device senses inbalance or residual currents in the system and disconnects supply system.

Residual Current Circuit Breaker

Tripping Characteristics (IEC/EN 61008) Tripping characteristics, tripping time range and selectivity of instantaneous, surge current-proof residual current circuit breaker.

Residual Current Circuit Breaker - RCCB Shape compatible with and suitable for standard busbar connection to other devices Twin-purpose terminal (lift/open-mouthed) above and below

I n3 = 30 mA 1000 (ms) 500 300

Contact position indicator red - green (FI7-4-pole) Suitable for being used with standard fluorescent tubes with or without electrical ballast (typically up to 20 units per phase conductor)

Tripping time range non-delayed 150

100

Area of unwanted tripping Tripping time t

Free terminal space despite installed busbar

Tripping time range limit values

300

Busbar positioning optionally line or load

40

10

10

10

40

40

10

10

conditionally

The device functions irrespective of the position of installation

surge currentproof 1

Types with 80 A permissible short-circuit back-up fuse: Take into account overload protection Tripping is line voltage-independent. Consequently, the RCCB is suitable for “fault current/residual current protection” and “additional protection” within the the meaning of the applicable installation rules Mains connection at either side The 4-pole device can also be used for 3-pole connection. For this purpose use terminals 1-2, 3-4, and 5-6. The 4-pole device can also be used for 2-pole connection. For this purpose use terminals N-N and 5-6. Pressing the test key “T” serves the only purpose of function testing the residual current circuit breaker (RCCB). This test does not make earthing resistance measurement (R E), or proper checking of the earth conductor condition redundant, which must be performed separately.

10

15

30

50

100

150

200

500

1000 (mA) 500 A)

Residual tripping current

I n1........ 2I n1........

I n

5I n1........

I n2........ 2I n2........ 5I n2........

Series connection of main RCCB and circuit RCCB's recommended by the installation rules set forth in ÖVE/ÖNORM E 8001-1, is compulsory for agricultural installations according to §56 of ÖVE-EN1, Part 4. The device is ok if the result of measurement is within the time range specified by the manufacturer of the measuring instrument.

Connection Diagrams 2-Pole

4-Pole

Technical Data Electrical

Residual Current Circuit Breaker General Data Short description of the most important RCCB types:

Description Standard. Suitable for outdoor installation (distribution boxes for outdoor installation and building sites) up to -25ºC. Conditionally surge-current proof (>250 A, 8/20 µs) for general application. Press service key when putting the device into operation, and subsequently approximately once per year. Pressing the key once per month is not required any more and can be omitted unless shorter testing intervals are required under any applicable regulations (e.g. on building sites).

Tripping time

Undelayed

Rated voltage

240 / 415 V; 50 Hz

Rated tripping current

30, 100, 300 mA

Sensitivity

AC

Rated short circuit strength

10kA with 63 A gL back-up fuse 10kA with 80 A gL (FI7-80) 6 kA (Rated Current 63A) with 63A A gL

Maximum back-up fuse 63 A gL for short circuit protection 80 A gL (FI7-80) Maximum back-up fuse for overload protection

25 A gL (FI7-25 and - 40 A) 40 A gL (FI7-63 and - 63 A) 50 A gL (FI7-80 A)

Resitance to climatic conditions

according to IEC/EN 61008

Degree of protection

built-in switch IP40

Endurance

Mechanical Frame size Socket size Device size Mounting

45 mm 80 mm 35 mm (2mod.), 70 mm (4 mod.) Qucik fastening with 2 lock-in positions on DIN rail EN50022 Open mouthed / lift terminals

Upper and lower terminals Terminal protection Finger and hand touch safe, BGV A3, ÖVE-EN 6 Terminal capacity Busbar thickness

1.5 mm2 - 35 mm2 0.8 - 2 mm

electrical > 4,000 change overs mechanical > 20,000 change overs

Dimensions

Symbol

For accessories please contact the nearest Sales Office

Unless otherwise specified, 2-pole devices (1p+N) are 2 module units wide and 4-pole devices (3p+N) are 4 module units wide.