DATA ENTRY FORM VESSEL NAME TERMINAL PORT DATE REPORT ISSUED INTERTEK FILE NUMBER
: : : : :
SK SPLENDOR OMAN LNG SUR, OMAN 5-Aug-2009 SUR/09/134
Program Version Number LNG-LD-009H1 (07-AUG-09)
CUSTOMER NAME ADDRESS #1 ADDRESS #2 ADDRESS #3 ADDRESS #4 ADDRESS #5 CONTACT NAME #1 CONTACT NAME #2 CONTACT NAME #3 CUSTOMER REFERENCE #1 CUSTOMER REFERENCE #2 SPA SUPPLIED BY
: : : : : : : : : : : :
OMAN LNG P.O. BOX 560 MUSCAT 116 SULTANATE OF OMAN
FOR INTERTEK USE ONLY
DO NOT ISSUE THIS PAGE TO CUSTOMERS
ACCOUNTS PAYABLE - NGF / 23 ATIQ AHMED OF039/09-SL100-KG OMAN LNG / KOGAS CORPORATION
IN ORDER FOR THIS PROGRAM TO WORK PROPERLY, MACROS MUST BE ENABLED
REPORT SETUP & GUIDELINES
Report of Quantity
1
SELECT TYPE OF REPORT OF QUANTITY SELECT TYPE OF REPORT OF QUANTITY ( STANDARD OR QUANTITY SPLIT).
1 2
0
Report of Gas Up
SELECT TO DISPLAY OR HIDE THE REPORT OF GAS-UP IF GAS-UP IS REQUIRED, SELECT WHICH CALCUALTION METHOD IS TO BE USED.
0 1 2
0
Report of Cool Down
Contract Used ( SPA )
0 1 2 3 4 5
14
1 2 3 4 5 Secondary 6 Custody 7 Transfer 8 Measurement 9 YES 10 NO 11 12 CTMS 13 "Snapshot" 14 15 Measurement 16 17 0 Page(s) 18 1 19 2 3 4
YES
0
SELECT TO DISPLAY OR HIDE THE REPORT OF COOL DOWN IF COOL DOWN IS REQUIRED, SELECT WHICH COOL DOWN CALCULATION METHOD IS TO BE USED.
SELECT WHICH CONTRACT (SPA) IS TO BE USED FOR CALCULATIONS ALL PAGES WILL AUTOMATICALLY CHANGE TO THE VALUES OF THE APPROPRIATE CALCULATION METHOD AS DESCRIBED IN THE RELEVANT CONTRACT (SPA)
SELECT TO DISPLAY OR HIDE THE SECONDARY CUSTODY TRANSFER MEASUREMENTS. SECONDARY CUSTODY TRANSFER PAGE RECORDS AND CALCULATES THE VOLUMES OF THE SECONDARY GAUGING SYSTEM FOR OPENING & CLOSING AND COMPARES THE VOLUMES TO THE PRIMARY SYSTEMS.
SELECT TO DISPLAY HOW MANY SNAPSHOT MEASUREMENT PAGES ARE NEEDED. CHOSE FROM ZERO TO FOUR ADDITIONAL CTMS "SNAPSHOT" MEASUREMENT PAGES.
0 1 2 3 4
1
Operational Checklist
SELECT TO WHICH OPERATIONAL CHECKLIST TO DISPLAY SELECT THE APPROPRIATE CHECKLIST TO BE DISPLAYED AND REPORTED.
1 2
0
Verification of
GC
Bunker Reports
0 1 2
NONE NONE BOTH FO ONLY DO ONLY
Letter(s) of Protest
Client Specific Reports
Report Revision Number
0 0 1 2 3 4
0
SELECT TO DISPLAY OR HIDE THE VERIFICATION OF GC PAGE IF NO VERIFICATION OF GC IS REQUIRED, OBTAIN A COPY OF THE TERMINAL'S VERIFICATION RECORDS BEFORE & AFTER. OBTAIN COPIES OF THE CERTIFICATIONS FOR THE SPAN GAS AND LAST CALIBRATION OF THE GC.
SELECT TO DISPLAY OR HIDE THE BUNKER REPORTS IF NO BUNKER REPORTS ARE REQUIRED, OBTAIN A COPY OF THE VESSEL'S BUNKER REPORT BEFORE & AFTER FROM THE CHIEF ENGINEER.
SELECT TO DISPLAY HOW MANY LETTER OF PROTEST ARE NEEDED. CHOSE FROM ZERO TO FOUR LETTERS OF PROTEST.
SELECT TO DISPLAY OR HIDE CLIENT SPECIFIC REPORTS SELECT IF ANY ADDITIONAL CLIENT SPECIFIC REPORT IS NEEDED OR NOT.
0 1 2 3 4 5
None
Provisional Final Revision 1 Revision 2 Revision 3 Page Numbers Revision 4 Required
NO
YES NO
SELECT TO IDENTIFY REVISED REPORT SELECT IF REPORT WAS REVISED AND WHICH REVISION NUMBER IS TO BE ISSUED
SELECT TO PLACE PAGE NUMBERS ON BOTTOM OF REPORT PAGES SELECT IF PAGE NUMBERS ARE NEEDED AT THE BOTTOM OF THE PAGES WITHIN THE REPORT
5-Aug-2009 OMAN LNG P.O. BOX 560 MUSCAT 116 SULTANATE OF OMAN ATTN : ATTN :
ACCOUNTS PAYABLE - NGF / 23 ATIQ AHMED
REFERENCE : FOR SERVICES RENDERED TO ATTEND THE LOADING OF L.N.G. ON BOARD THE VESSEL "SK SPLENDOR" FOR THE ENERGY DELIVERED AT OMAN LNG / SUR, OMAN ON 4-Aug-2009 TO 5-Aug-2009 OUR REFERENCE : YOUR REFERENCE :
SUR/09/134 OF039/09-SL100-KG
DEAR SIR / MADAM: ENCLOSED FOR YOUR REVIEW IS OUR REPORT COVERING THE VESSEL "SK SPLENDOR" AT THE ABOVE LOCATION ON THE DATES INDICATED. THE ENERGY VALUES WERE CALCULATED AS PER THE SPA SUPPLIED BY OMAN LNG / KOGAS CORPORATION SHOULD YOU HAVE ANY QUESTIONS REGARDING THIS REPORT PLEASE DO NOT HESITATE TO CONTACT US AT YOUR CONVENIENCE. WE THANK YOU FOR REQUESTING OUR SERVICES.
RESPECTFULLY FOR, INTERTEK CALEB BRETT PONNAPPA CHOKIRA MANAGER
INTERTEK OIL CHEMICAL & AGRI P.O. BOX 39, PC 114 MINA AL FAHAL SULTANATE OF OMAN TELEPHONE +968 (2) 448 0229 LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF LOADING VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
1. LAST PORT INFORMATION LAST PORT TERMINAL / PORT LAST PORT C.C.T. QUANTITY LAST PORT C.C.T. INSPECTION
: :
KOGAS / INCHEON 1,553.335 CUBIC METERS DATE : 20-Jul-2009 TIME : 15:48
2. OPENING CUSTODY TRANSFER INFORMATION OPENING CUSTODY TRANSFER VOLUME OPENING CUSTODY TRANSFER TEMPERATURES OPENING CUSTODY TRANSFER TANK PRESSURE OPENING CUSTODY TRANSFER INSPECTION
: : :
404.978 CUBIC METERS -146.2 °C - Liquid -128.5 °C - Vapor 1166 mbar DATE : 4-Aug-2009 TIME : 10:28
3. CLOSING CUSTODY TRANSFER INFORMATION CLOSING CUSTODY TRANSFER VOLUME CLOSING CUSTODY TRANSFER TEMPERATURE CLOSING CUSTODY TRANSFER TANK PRESSURE CLOSING CUSTODY TRANSFER INSPECTION
: : :
136,292.944 CUBIC METERS -160.2 °C - Liquid -152.0 °C - Vapor 1101.5 mbar DATE : 5-Aug-2009 TIME : 04:17
4. VESSEL COOL DOWN WAS NOT REQUIRED COOL DOWN TRANSFER VOLUME COOL DOWN TRANSFER TEMPERATURE COOL DOWN TRANSFER TANK PRESSURE COOL DOWN TRANSFER INSPECTION
: : :
--- CUBIC METERS --- °C - Liquid --- °C - Vapor --- mbar DATE : --TIME : ---
5-Aug-2009
5. LOAD INFORMATION ** VESSEL DELIVERED VOLUME (LIQUID) AT -160.2 °C : 135,888.000 CUBIC METERS ** VESSEL DELIVERED VOLUME (LIQUID) AT -160.2 °C : 135,888,000 LITERS ** VESSEL DELIVERED VOLUME (LIQUID) AT -160.0 °C : 135,971.000 CUBIC METERS VESSEL DELIVERED VOLUME (GAS) : 2,876.574 MILLION CUBIC FEET @ S.R.C. VESSEL DELIVERED VOLUME (GAS) : 81,455.497 1000 CUBIC METERS @ S.R.C. ** LIQUID TEMPERATURE AFTER LOADING : -160.2 °C ** VAPOR TEMPERATURE BEFORE LOADING : -128.5 °C ** TANK PRESSURE BEFORE LOADING : 1166 mbar ** LNG DENSITY AT -160.2 °C : 459.080 kg / m3 ** LNG DENSITY AT -160.0 °C 458.800 kg / m4 MASS DELIVERED : 62,172.077 METRIC TONS ** GROSS HEATING VALUE (MASS) : 54.44 MJ / kg ** GROSS HEATING VALUE (VOLUME) : 1115 BTU / SCF ** WOBBE INDEX : 1411 BTU / SCF ** INDICATED VALUES ARE ROUNDED IN ACCORDANCE WITH SPECIFIC S.P.A. REQUIREMENTS 6. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF QUANTITY VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. CUSTODY TRANSFER DENSITY
459.080
LNG DENSITY AT -160.2 °C
kg / m3
2. CUSTODY TRANSFER VOLUME & MASS CUBIC METERS
KILOGRAMS
METRIC TONS
135,888.000
62,172,077
62,172.077
QUANTITY CONSUMED BY VESSEL
0.000
0
0.000
QUANTITY USED FOR GAS-UP
0.000
0
0.000
QUANTITY USED FOR COOL DOWN
0.000
0
0.000
135,888.000
62,172,077
62,172.077
MEGAJOULES
MMBTU
KILOWATT HOURS
3,395,719,322
3,218,508
943,255,367
QUANTITY DISPLACED
11,743,022
11,130
3,261,951
QUANTITY DELIVERED
3,383,978,343
3,207,380
939,993,417
QUANTITY CONSUMED BY VESSEL
0
0
0
QUANTITY USED FOR GAS-UP
0
0
0
QUANTITY USED FOR COOL DOWN
0
0
0
3,383,978,343
3,207,380
939,993,417
QUANTITY RECEIVED BY VESSEL
ADJUSTED QUANTITY DELIVERED
3. CUSTODY TRANSFER ENERGY
GROSS QUANTITY DELIVERED
ADJUSTED QUANTITY DELIVERED
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
4. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT ROQ 1 - Standard
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF QUANTITY VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. CUSTODY TRANSFER DENSITY
459.080
LNG DENSITY AT -160.2 °C
kg / m3
2. CUSTODY TRANSFER VOLUME & MASS CUBIC METERS
KILOGRAMS
METRIC TONS
135,888.000
62,172,077
62,172.077
QUANTITY CONSUMED BY VESSEL
0.000
0
0.000
QUANTITY USED FOR GAS-UP
0.000
0
0.000
QUANTITY USED FOR COOL DOWN
0.000
0
0.000
135,888.000
62,172,077
62,172.077
MEGAJOULES
MMBTU
KILOWATT HOURS
3,395,719,322
3,218,508
943,255,367
QUANTITY DISPLACED
11,743,022
11,130
3,261,951
QUANTITY DELIVERED
3,383,978,343
3,207,380
939,993,417
QUANTITY CONSUMED BY VESSEL
0
0
0
QUANTITY USED FOR GAS-UP
0
0
0
QUANTITY USED FOR COOL DOWN
0
0
0
3,383,978,343
3,207,380
939,993,417
QUANTITY RECEIVED BY VESSEL
ADJUSTED QUANTITY DELIVERED
3. CUSTODY TRANSFER ENERGY
GROSS QUANTITY DELIVERED
ADJUSTED QUANTITY DELIVERED
THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
4. QUANTITY SPLITS CARGO NUMBER
CUBIC METERS
METRIC TONS
MEGAJOULES
MMBTU
KILOWATT HOURS
1
T-54674-Y03
63,888.000
29,230.319
1,590,983,813
1,507,956
441,939,681
2
T-54674-Y04
42,000.000
19,216.025
1,045,913,476
991,331
290,531,346
3
T-54674-Y05
10,000.000
4,575.244
249,027,018
236,031
69,174,130
4
T-54674-Y06
20,000.000
9,150.488
498,054,036
472,062
138,348,260
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT ROQ 2 - Quantity Split
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF ANALYSIS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN 1. DESCRIPTION SAMPLE DESIGNATED AS SAMPLE TESTED BY SAMPLE REPRESENTING
DATE
:
4-Aug-2009
TO
5-Aug-2009
: LIQUEFIED NATURAL GAS : TERMINAL IN-LINE GC - VERIFIED PRIOR TO LOADING : COMPOSITE CONTINUOUS SAMPLING
2. ANALYSIS TEST
METHOD
METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN
GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261
LIQUID COMPOSITION 90.2400 5.9500 2.2400 0.6900 0.5800 0.0200 0.0000 0.0000 0.2800 0.0000 0.0000
MERCURY MERCAPTANS HYDROGEN SULFIDE CARBONYL SULFIDE TOTAL SULFUR HYDROCARBON DEWPOINT (MAX) 3. QUALITY SPECIFICATIONS (SPA DEFINED) TEST NONE SPECIFIED
% mol % mol % mol % mol % mol % mol % mol % mol % mol % mol % mol ng / Nm3 mg / Nm3 mg / Nm3 mg / Nm3 mg / Nm3 °C
SPECIFICATION N/A
NOT TESTED NOT TESTED NOT TESTED NOT TESTED NOT TESTED NOT TESTED
RESULT N/A
4. ADDITIONAL INFORMATION AND COMMENTS THE TEST RESULTS IN THIS DOCUMENT HAVE BEEN PROVIDED TO INTERTEK CALEB BRETT BY THE TERMINAL AND ARE PASSED ON FOR INFORMATIONAL PURPOSES ONLY. INTERTEK CALEB BRETT MAKES NO REPRESENTATION AS TO THE QUALITY OF THE MATERIAL AND ASSUMES NO RESPONSIBILITY FOR THE ACCURACY OF THE TEST RESULTS, WHICH REMAINS SOLELY WITH THE ABOVE MENTIONED PRODUCER OF THE RESULTS. THE ISSUING OF THIS REPORT DOES NOT CONSTITUTE ANY REPRESENTATION OR WARRANTY CONCERNING THE INFORMATION CONTAINED HEREIN.
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF GAS-UP VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. METHOD OF GAS-UP CALCULATION GAS-UP VALUES ARE CALCULATED BY MULTIPLYING TANK CAPACITY BY A CONSTANT VOLUME FACTOR SUBMITTED BY THE VESSEL. THE FACTOR IS DETERMINED BY THE DESIGN OF THE VESSEL TANKS.
2. CALCULATION OF VAPOR VOLUME USED FOR GAS-UP TANK NAME TANK CAPACITY
m3
FACTOR VOLUME USED
m3
1
2
3
4
37,326.000
37,336.000
37,352.000
37,345.000
1.800
1.800
1.800
1.800
67,186.800
67,204.800
67,233.600
67,221.000
3. CALCULATION VALUES FOR GAS-UP OPERATIONS VAPOR VOLUME USED FOR GAS-UP
=
268,846.200
VAPOR TEMPERTURE AFTER GAS-UP
=
24.0
VAPOR PRESSURE AFTER GAS-UP
=
1171
DENSITY OF VAPOR VOLUME FOR GAS-UP
=
0.7634
DENSITY OF LIQUID (AT LNG LOADING TEMPERATURE)
=
459.080
HIGHER HEATING VALUE (MASS)
=
54.436
HIGHER HEATING VALUE (VOLUME)
=
1115
CUBIC METERS °C mbar kg / m3 at 60°F (Ideal Gas) kg / m3 at -160.2°C MJ / kg at 15°C BTU / SCF at 60/60°F & 14.696 psi
4. VOLUME, MASS, & ENERGY USED FOR GAS-UP OPERATIONS LNG EQUIVALENT USED FOR GAS-UP
=
501.918
CUBIC METERS at -160.2°C
MASS REQUIRED FOR GAS-UP
=
230.420
METRIC TONS
ENERGY REQUIRED FOR GAS-UP
=
12,542,489
ENERGY REQUIRED FOR GAS-UP
=
11,888
MMBTU at @ 60°F
ENERGY REQUIRED FOR GAS-UP
=
3,484,025
MMBTU at @ 60°F
MJ at @ 60°F
5. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT ROGU 1 - Factor Calculation
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF GAS-UP VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. METHOD OF GAS-UP CALCULATION GAS-UP VALUES ARE CALCULATED BY MUTIAL AGREEMENT BETWEEN ALL PARTIES. THE VOLUME AS CALCUALTED BY FLOW METER LOCATED ASHORE. THE VOLUME REPORTED WAS SUBMITTED BY THE TERMINAL.
2. SUBMITTED VOLUME USED FOR GAS-UP =
263,487.600
CUBIC METERS (VAPOR)
VAPOR VOLUME USED FOR GAS-UP
=
263,487.600
CUBIC METERS
VAPOR TEMPERTURE AFTER GAS-UP
=
24.0
VAPOR PRESSURE AFTER GAS-UP
=
1171
DENSITY OF VAPOR VOLUME FOR GAS-UP
=
0.7634
DENSITY OF LIQUID (AT LNG LOADING TEMPERATURE)
=
459.080
HIGHER HEATING VALUE (MASS)
=
54.436
HIGHER HEATING VALUE (VOLUME)
=
1115
SUBMITTED VOLUME USED FOR GAS-UP
3. CALCULATION VALUES FOR GAS-UP OPERATIONS
°C mbar kg / m3 at 60°F (Ideal Gas) kg / m3 at -160.2°C MJ / kg at 15°C BTU / SCF at 60/60°F & 14.696 psi
4. VOLUME, MASS, & ENERGY USED FOR GAS-UP OPERATIONS LNG EQUIVALENT USED FOR GAS-UP
=
491.914
CUBIC METERS at -160.2°C
MASS REQUIRED FOR GAS-UP
=
225.828
METRIC TONS
ENERGY REQUIRED FOR GAS-UP
=
12,289,447
ENERGY REQUIRED FOR GAS-UP
=
11,648
MMBTU at @ 60°F
ENERGY REQUIRED FOR GAS-UP
=
3,413,735
MMBTU at @ 60°F
MJ at @ 60°F
5. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT ROGU 1 - Factor Calculation
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF COOL DOWN VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. METHOD OF COOL DOWN CALCULATION COOL DOWN VALUES ARE CALCULATED BY THE LIQUID VOLUME PER VAPOR TEMPERATURE DIFFERENTIAL METHOD. 2. PROCEDURE FOR METHOD THE DIFFERENCE OF THE VAPOR TEMPERATURES TAKEN DURING OPENING CUSTODY TRANSFER AND AFTER COOL DOWN MEASUREMENT IS MULTIPLIED BY A LIQUID VOLUME PER 1°C. THIS LIQUID VOLUME IS DEFINED WITHIN THE VESSEL'S CALIBRATION TABLES AND IS SUBMITTED BY THE CHIEF OFFICER. THE TANK TEMPERATURE IS IDENTIFIED AS : THE AVERAGE OF ONLY THE BOTTOM 2 TEMPERATURE PROBES LIQUID VOLUME REQUIRED TO LOWER THE VAPOR TEMPERATURE BY 1°C = 2.150 CUBIC METERS CALCULATED DENSITY OF CARGO LOADED = 459.080 kg / m3 at -160.2 °C HIGHER HEATING VALUE OF CARGO LOADED = 54.44 MJ / kg at 15°C 3. TANK TEMPERATURE CALCULATIONS TANK NAME 1 2 TEMP. PRIOR °C 28.00 28.00 TEMP. AFTER °C CASE #1 CASE #1 TEMP. DIFF °C #VALUE! #VALUE! M3 PER 1°C 2.150 2.150 M3 PER TANK #VALUE! #VALUE!
3 27.00 CASE #1 #VALUE! 2.150 #VALUE!
4 27.00 CASE #1 #VALUE! 2.150 #VALUE!
4. REPORTING VALUES FOR COOL DOWN OPERATIONS LIQUID VOLUME REQUIRED FOR COOL DOWN
=
#VALUE!
CUBIC METERS at -160.2 °C
MASS REQUIRED FOR COOL DOWN
=
#VALUE!
METRIC TONS
ENERGY REQUIRED FOR COOL DOWN
=
#VALUE!
MJ at @ 60°F
ENERGY REQUIRED FOR COOL DOWN
=
#VALUE!
MMBTU at @ 60°F
ENERGY REQUIRED FOR COOL DOWN
=
#VALUE!
KWH at @ 60°F
5. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT ROCD 1 - Temperature Differential
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF COOL DOWN VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. METHOD OF COOL DOWN CALCULATION COOL DOWN VALUES ARE CALCULATED BY THE COOL DOWN TABLES METHOD. 2. PROCEDURE FOR METHOD THE ENERGY REQUIRED TO COOL DOWN THE VESSEL TANKS TO THE REQUIRED LOADING TEMPERATURE IS OBTAINED FROM VESSEL'S CERTIFIED COOL DOWN TABLES SUBMITTED BY THE CHIEF OFFICIER. THE TABLES ARE DIVIDED INTO TWO SECTIONS. CASE #1 IS FOR WARM CONDITIONS (AVERAGE TEMPERTAURE BEING HIGHER THAN -40°C). CASE #2 IS FOR COLD CONDITIONS (AVERAGE TEMPERATURE BEING LOWER THAN -40°C). THE TANK TEMPERATURE IS IDENTIFIED AS : THE AVERAGE OF ONLY THE TOP & BOTTOM TEMPERATURE PROBES COOL DOWN TABLES PRESENTED USING : MMBTUS TEMPERATURES FOR CASE #1 TABLES ARE BETWEEN 40.0 °C AND -40.0 °C TEMPERATURES FOR CASE #2 TABLES ARE BETWEEN -40.0 °C AND -130.0 °C CALCULATED DENSITY OF CARGO LOADED = 459.080 kg / m3 at -160.2 °C HIGHER HEATING VALUE OF CARGO LOADED = 54.44 MJ / kg at 15°C 3. TANK TEMPERATURE CALCULATIONS TANK NAME 1 2 TEMPERATURE °C 28.00 28.00 TABLE USED CASE #2 CASE #2 MMBTUS 1625 2988
3 27.00 CASE #2 2988
4 27.00 CASE #2 2794
4. REPORTING VALUES FOR COOL DOWN OPERATIONS LIQUID VOLUME REQUIRED FOR COOL DOWN
=
438.860
CUBIC METERS at -160.2 °C
MASS REQUIRED FOR COOL DOWN
=
201.472
METRIC TONS
ENERGY REQUIRED FOR COOL DOWN
=
10,967,349
ENERGY REQUIRED FOR COOL DOWN
=
10,395
ENERGY REQUIRED FOR COOL DOWN
=
3,046,486
MJ at @ 60°F MMBTU at @ 60°F KWH at @ 60°F
5. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT ROCD 2 - Vessel Tables
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF COOL DOWN VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. METHOD OF COOL DOWN CALCULATION COOL DOWN VALUES ARE CALCULATED BY THE SPRAY NOZZLE FLOW & PRESSURE METHOD. 2. PROCEDURE FOR METHOD THE VOLUME REQUIRED TO COOL DOWN THE VESSEL TANKS TO THE REQUIRED LOADING TEMPERATURE IS OBTAINED BY CALCULATING THE VOLUME BASED ON THE NUMBER OF SPRAY NOZZLES PER TANK, FLOW CAPACITY PER NOZZLE, DURATION OF COOL DOWN, AND THE DENSITY OF THE LNG. CALCULATED DENSITY OF CARGO LOADED HIGHER HEATING VALUE OF CARGO LOADED 3. TANK PROFILE TANK NAME # OF NOZZLES FLOW RATE (L/MIN) DURATION (HOURS) DENSITY FACTOR CUBIC METERS
1 22 1.80 9.80 1.4759 34.366
= =
2 34 1.80 9.80 1.4759 53.111
459.080 kg / m3 at -160.2 °C 54.44 MJ / kg at 15°C
3 34 1.80 9.80 1.4759 53.111
4 32 1.80 9.80 1.4759 49.987
4. REPORTING VALUES FOR COOL DOWN OPERATIONS LIQUID VOLUME REQUIRED FOR COOL DOWN
=
190.575
MASS REQUIRED FOR COOL DOWN
=
87.489
ENERGY REQUIRED FOR COOL DOWN
=
4,762,303
ENERGY REQUIRED FOR COOL DOWN
=
4,514
ENERGY REQUIRED FOR COOL DOWN
=
1,322,862
CUBIC METERS at -160.2 °C METRIC TONS MJ at @ 60°F MMBTU at @ 60°F KWH at @ 60°F
5. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT ROCD 3 - Nozzle Flow
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF COOL DOWN VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. METHOD OF COOL DOWN CALCULATION COOL DOWN VALUES ARE CALCULATED BY USING THE NIGERIA LNG TERMINAL SUBMITTED PROCEDURE. 2. PROCEDURE FOR METHOD THE ENERGEY REQUIRED TO COOL DOWN THE VESSEL TANKS TO THE REQUIRED LOADING TEMPERATURE IS OBTAINED BY THE COMMON INDUSTRY FORMULA OF "ENERGY = VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED)". THE VOLUME OF LNG (IN CUBIC METERS) WAS SUBMITTED BY THE TERMINAL. THE DENSITY OF THE LNG WAS CALCULATED BY USING NBS TECHNICAL NOTE 1030 (1980). THE HIGHER HEATING VALUE (MASS BASED) WAS CALCULATED BY USING THE STANDARD ISO 6976.
3. REPORTING VALUES FOR COOL DOWN OPERATIONS LIQUID VOLUME REPORTED FOR COOL DOWN
=
640.830
CUBIC METERS at -160.2 °C
DENSITY OF LNG
=
459.080
kg / m3 at -160.2 °C
HIGHER HEATING VALUE (MASS)
=
54.44
MJ / kg at 15°C
MASS REQUIRED FOR COOL DOWN
=
294.192
METRIC TONS
ENERGY REQUIRED FOR COOL DOWN
=
16,013,781
ENERGY REQUIRED FOR COOL DOWN
=
15,178
ENERGY REQUIRED FOR COOL DOWN
=
4,448,273
MJ at @ 60°F MMBTU at @ 60°F KWH at @ 60°F
4. ADDITION INFORMATION AND COMMENTS PLEASE NOTE THAT WITH RESPECT TO THE CALCULATION OF COOL DOWN QUANTITY THE TERMINAL PROCEDURE DIFFERS FROM NORMAL ACCEPTED INDUSTRY PRACTISE, WE ARE HOWEVER REQUIRED TO REPORT THE QUANTITY IN ACCORDANCE WITH TERMINAL PROCEDURES.
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT ROCD 4 - Submitted Shore
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF COOL DOWN VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. METHOD OF COOL DOWN CALCULATION COOL DOWN VALUES ARE CALCULATED BY THE COOL DOWN TABLES PLUS LIQUID FALL OUT METHOD. 2. PROCEDURE FOR METHOD THE ENERGY REQUIRED TO COOL DOWN THE VESSEL TANKS TO THE REQUIRED LOADING TEMPERATURE IS OBTAINED FROM VESSEL'S CERTIFIED COOL DOWN TABLES SUBMITTED BY THE CHIEF OFFICIER. THE TABLES ARE DIVIDED INTO TWO SECTIONS. CASE #1 IS FOR WARM CONDITIONS (AVERAGE TEMPERTAURE BEING HIGHER THAN °C). CASE #2 IS FOR COLD CONDITIONS (AVERAGE TEMPERATURE BEING LOWER THAN °C). THE TANK TEMPERATURE IS IDENTIFIED AS : THE AVERAGE OF TANK TEMPERATURES COOL DOWN TABLES PRESENTED USING : MMBTUS CALCULATED DENSITY OF CARGO LOADED = 459.080 kg / m3 at -160.2 °C HIGHER HEATING VALUE OF CARGO LOADED = 54.44 MJ / kg at 15°C 3. CALCULATIONS OF CONSUMED VALUES FOR COOL DOWN TANK NAME 1 2 3 TEMP BEFORE °C 29.10 29.40 28.80 TEMP AFTER °C 30.10 29.40 28.80 MMBTUS 2473 3638 3626 VOLUME OF LIQUID CONSUMED FOR COOL DOWN = MASS CONSUMED FOR COOL DOWN = ENERGY CONSUMED FOR COOL DOWN = ENERGY CONSUMED FOR COOL DOWN = ENERGY CONSUMED FOR COOL DOWN = 4. CALCULATIONS OF FALLOUT VALUES AFTER COOL DOWN TANK NAME 1 2 3 VOLUME BEFORE m3 21.371 37.771 38.761 VOLUME AFTER m3 47.856 44.726 60.576 VOLUME LOADED m3 26.485 6.955 21.815 VOLUME OF LIQUID FALLOUT AFTER COOL DOWN = MASS OF FALLOUT AFTER COOL DOWN = ENERGY OF FALLOUT AFTER COOL DOWN = ENERGY OF FALLOUT AFTER COOL DOWN = ENERGY OF FALLOUT AFTER COOL DOWN =
4 29.50 29.50 3358 552.849 253.802 13,815,237 13,090 3,837,566
CUBIC METERS METRIC TONS MJ at 60°F MMBTU at 60°F KWH at 60°F
4 307.075 59.168 -247.907 192.652 88.443 4,814,205 4,560 1,337,279
CUBIC METERS METRIC TONS MJ at 60°F MMBTU at 60°F KWH at 60°F
5. TOTAL VALUES FOR COOL DOWN OPERATIONS TOTAL VOLUME OF LIQUID REQUIRED FOR COOL DOWN
=
745.501
CUBIC METERS
TOTAL MASS REQUIRED FOR COOL DOWN
=
342.245
METRIC TONS
TOTAL ENERGY REQUIRED FOR COOL DOWN
=
18,629,442
TOTAL ENERGY REQUIRED FOR COOL DOWN
=
17,650
TOTAL ENERGY REQUIRED FOR COOL DOWN
=
5,174,845
MJ at 60°F MMBTU at 60°F KWH at 60°F
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT
FOR TERMINAL
ROCD 5 - Vessel Tables + Fall Out
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE + HEAVIER NITROGEN
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.902400 0.059500 0.022400 0.006900 0.005800 0.000200 0.000000 0.002800
16.043 30.070 44.097 58.123 58.123 72.150 72.150 28.0135
0.038122 0.047925 0.062478 0.078332 0.076856 0.091700 0.091562 0.046882
55.57 51.95 50.37 49.39 49.55 48.95 49.04 0
2. DENSITY CALCULATIONS DENSITY
=
DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
459.166
WITH C = K1 +
kg/m3 at -160.2 °C
( K2 - K1 ) * Xn 0.04 K1 = 0.000427
K2 = 0.000685
3. HIGHER HEATING VALUES Hm (MASS)
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi ) Σ ( Xi * Mi * Hi) * 101.325 8.31451 * 288.15
=
15°C
Hv (VOLUME) 15/15°C
=
at 101.325 kPa
WOBBE INDEX
15/15°C at
101.325 kPa
=
Hv / √
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
Hm (MASS) 15°C
Hv (VOLUME) 15/15°C
54.4355
MJ / kg
=
41.6357
MJ / m3
=
52.6895
MJ / m3
at 101.325 kPa
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
=
15/15°C at
101.325 kPa
-160.2 °C -128.5 °C 1166.000 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
404.978 m3 136,292.944 m3 135,887.966 m3
5. ENERGY DELIVERED GROSS QUANTITY DELIVERED
=
VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED)
GROSS DELIVERED QUANTITY
=
3,396,507,919
GROSS DELIVERED QUANTITY
=
3,219,267.90
GROSS DELIVERED QUANTITY
=
943,474,422
MJ MMBTU KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. TECHNICAL NOTE 1030 (1980). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 1
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hmi)
MOLAR HHV MJ / m3 (Hvi)
METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN OXYGEN
0.902400 0.059500 0.022400 0.006900 0.005800 0.000200 0.000000 0.000000 0.002800 0.000000
16.043 30.070 44.097 58.123 58.123 72.150 72.150 86.177 28.0135 31.9988
0.038118 0.047922 0.062475 0.078328 0.076852 0.091695 0.091558 0.104864 0.046876 0.031467
55.57 51.95 50.37 49.39 49.55 48.95 49.04 48.72 0 0
37.71 66.07 93.94 121.40 121.79 149.36 149.66 177.55 0 0
SUMMATION FACTOR (√Bi) 0.0447 0.0922 0.1338 0.1789 0.1871 0.2280 0.2510 0.2950 0.0173 0.0283
2. DENSITY CALCULATIONS DENSITY
=
DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
459.159
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.24 °C
K1 = 0.000422
K2 = 0.000681
3. HIGHER HEATING VALUES Hm (MASS)
Σ ( Xi * Mi * Hmi ) Σ ( Xi * Mi )
=
15°C
Hv (VOLUME) 15/15°C
Hm (MASS) 15°C
Hv (VOLUME)
Σ ( Xi * Hvi ) / Z
=
15/15°C
at 101.325 kPa
=
54.4355
MJ / kg
=
41.7448
MJ / m3
=
52.7692
MJ / m3
at 101.325 kPa
WOBBE INDEX
15/15°C at
101.325 kPa
Hv / √
=
Σ ( Xi * Mi ) 28.96
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
= = =
WOBBE INDEX
1 Z
*
15/15°C at
101.325 kPa
-160.24 °C -128.49 °C 1166.000 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
404.978 m3 136,292.944 m3 135,887.966 m3
5. ENERGY DELIVERED QUANTITY
=
V * D * Hm - Qr
WITH
Qr
=
V *
288.15 ( 273.15 + Tv )
*
Pa 1013.25
*
37.782 (Real Gas)
GROSS QUANTITY
=
3,396,458,942
MJ
or
3,219,221.48
MMBTU
or
943,460,817
KWH
ENERGY DISPLACED
=
11,768,417
MJ
or
11,154.31
MMBTU
or
3,269,005
KWH
NET QUANTITY
=
3,384,690,525
MJ
or
3,208,067.18
MMBTU
or
940,191,812
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.S.O. 6578 (1991). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 2
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0028
16.043 30.070 44.097 58.123 58.123 72.150 72.150 28.0135
0.038122 0.047925 0.062478 0.078332 0.076856 0.091700 0.091562 0.046882
55.57 51.95 50.37 49.39 49.55 48.95 49.04 0
METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE + HEAVIER NITROGEN 2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.16
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.2 °C
K1 = 0.000427
K2 = 0.000685
3. HIGHER HEATING VALUES Hm (MASS)
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi ) Σ ( Xi * Mi * Hi) * 26.8392 23.64
=
15°C
Hv (VOLUME) 60/60°F
=
at 14.696 PSI
WOBBE INDEX
60/60°F at
14.696 PSI
Hv / √
=
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
54.4
=
1117.5
BTU / SCF
=
1414.2
BTU / SCF
at 14.696 PSI
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
=
60/60°F at
14.696 PSI
-160.2 °C -128.5 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
MJ / kg
404.978 m3 136,292.944 m3 135,887.000 m3
5. ENERGY DELIVERED Q
=
( V * D * Hm - Qr ) / 1055.12
With Qr
=
V *
288.15 ( 273.15 + Tv )
*
Pa 1013.25
*
37.7 (Ideal Gas)
GROSS QUANTITY
=
3,394,020,913
MJ
or
3,216,911
MMBTU
or
942,783,587
KWH
ENERGY DISPLACED
=
11,742,891
MJ
or
11,130
MMBTU
or
3,261,914
KWH
NET QUANTITY
=
3,382,277,424
MJ
or
3,205,780
MMBTU
or
939,521,673
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. TECHNICAL NOTE 1030 (1980). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 3
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE + HEAVIER NITROGEN
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.902400 0.059500 0.022400 0.006900 0.005800 0.000200 0.000000 0.002800
16.043 30.070 44.097 58.123 58.123 72.150 72.150 28.0135
0.038116 0.047922 0.062475 0.078328 0.076852 0.091695 0.091558 0.046855
55.57 51.95 50.37 49.39 49.55 48.95 49.04 0
2. DENSITY CALCULATIONS DENSITY
=
DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
459.226
WITH C = K1 +
kg/m3 at -160.24 °C
( K2 - K1 ) * Xn 0.04 K1 = 0.000427
K2 = 0.000683
3. HIGHER HEATING VALUES Hm (MASS)
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi ) Σ ( Xi * Mi * Hi) 23.64
=
15°C
Hv (VOLUME) 15/15°C
=
at 101.325 kPa
WOBBE INDEX
15/15°C at
101.325 kPa
=
Hv / √
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
Hm (MASS) 15°C
Hv (VOLUME) 15/15°C
54.436
MJ / kg
=
41.636
MJ / m3
=
52.690
MJ / m3
at 101.325 kPa
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
=
15/15°C at
101.325 kPa
-160.24 °C -128.49 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
404.978 m3 136,292.944 m3 135,887.966 m3
5. ENERGY DELIVERED GROSS QUANTITY DELIVERED
=
VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED)
GROSS DELIVERED QUANTITY
=
3,396,985,335
GROSS DELIVERED QUANTITY
=
3,219,720
GROSS DELIVERED QUANTITY
=
943,607,038
MJ MMBTU KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. TECHNICAL NOTE 1030 (1980). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT
FOR TERMINAL
FOR VESSEL
SPA Contract # 4
LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE + HEAVIER NITROGEN
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.902400 0.059500 0.022400 0.006900 0.005800 0.000200 0.000000 0.002800
16.043 30.070 44.097 58.123 58.123 72.150 72.150 28.0135
0.038122 0.047925 0.062478 0.078332 0.076856 0.091700 0.091562 0.046882
55.52 51.9 50.33 49.35 49.51 48.91 49.01 0
2. DENSITY CALCULATIONS DENSITY
=
DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
459.166
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.2 °C
K1 = 0.000427
K2 = 0.000685
3. HIGHER HEATING VALUES Hm (MASS)
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi ) Σ ( Xi * Mi * Hi) * 101.325 8.31451 * 288.15 * Z
=
25°C
Hv (VOLUME) 25/15°C
=
at 101.325 kPa
WOBBE INDEX
25/15°C at
101.325 kPa
Hv / √
=
Σ ( Xi * Mi ) 28.96
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
25°C
Hv (VOLUME) 25/15°C
=
54.3803
MJ / kg
=
41.7030
MJ / m3
=
52.7163
MJ / m3
at 101.325 kPa
WOBBE INDEX
1 Z
*
= = =
Hm (MASS)
25/15°C at
101.325 kPa
-160.2 °C -128.5 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
404.978 m3 136,292.944 m3 135,888.000 m3
5. ENERGY DELIVERED QUANTITY
=
V * D * Hm - Qr
WITH
Qr
=
V *
288.15 ( 273.15 + Tv )
*
Pa 1013.25
*
38.8 (Real Gas)
GROSS QUANTITY
=
3,393,063,009
MJ
or
3,216,002.76
MMBTU
or
942,517,503
KWH
ENERGY DISPLACED
=
12,086,344
MJ
or
11,455.64
MMBTU
or
3,357,318
KWH
NET QUANTITY
=
3,380,976,665
MJ
or
3,204,547.12
MMBTU
or
939,160,185
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 25°C. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. TECHNICAL NOTE 1030 (1980). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 5
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000 0.0000
16.043 30.070 44.097 58.124 58.124 72.151 72.151 86.178 28.013 44.010 31.999
0.038122 0.047925 0.062479 0.078332 0.076857 0.091699 0.091562 0.104877 0.046866 0.027180 0.031474
55.560 51.926 50.39 49.4 49.54 48.94 49.05 48.72 0 0 0
METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN 2. DENSITY CALCULATIONS DENSITY
=
DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
459.082
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.2 °C
K1 = 0.000419
K2 = 0.000685
3. HIGHER HEATING VALUES Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
=
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi )
=
1.13285 * Σ ( Xi * Mi * Hi )
Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
at 14.696 PSIA
=
54.4233
=
1115.0
BTU / SCF
=
1411.0
BTU / SCF
at 14.696 PSIA
WOBBE INDEX
60/60°F at
14.696 PSIA
Hv / √
=
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
60/60°F at
14.696 PSIA
-160.2 °C -128.5 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
MJ / kg
404.978 m3 136,292.944 m3 135,888.000 m3
5. ENERGY DELIVERED Q
=
( V * D * Hm - Qr ) / 1055.12
With Qr
=
V *
288.15 ( 273.15 + Tv )
*
Pa 1013.25
*
37.7 (Ideal Gas)
GROSS QUANTITY
=
3,394,935,649
MJ
or
3,217,765
MMBTU
or
943,037,680
KWH
ENERGY DISPLACED
=
11,743,022
MJ
or
11,130
MMBTU
or
3,261,951
KWH
NET QUANTITY
=
3,383,192,627
MJ
or
3,206,640
MMBTU
or
939,775,730
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. INTERAGENCY REPORT 77-867. THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.P. 251/76.
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 6
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hmi)
MOLAR HHV MJ / m3 (Hvi)
METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN OXYGEN
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000
16.0426 30.0694 44.0962 58.1230 58.1230 72.1498 72.1498 86.1760 28.0134 31.9988
0.038123 0.047925 0.062479 0.078332 0.076856 0.091699 0.091562 0.104868 0.046900 0.031474
55.57 51.95 50.37 49.39 49.55 48.95 49.04 48.72 0 0
39.78 69.69 99.09 128.07 128.48 157.57 157.87 187.30 0 0
SUMMATION FACTOR (√Bi) 0.0490 0.1000 0.1453 0.2049 0.2069 0.2510 0.2864 0.3286 0.0224 0.0316
2. DENSITY CALCULATIONS DENSITY
=
DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
459.093
WITH C = K1 +
kg/m3 at -160.2 °C
( K2 - K1 ) * Xn 0.04 K1 = 0.000423
K2 = 0.000682
3. HIGHER HEATING VALUES Hm (MASS)
Σ ( Xi * Mi * Hmi ) Σ ( Xi * Mi )
=
15°C
Hv (VOLUME) 15/0°C
Hm (MASS) 15°C
Hv (VOLUME)
Σ ( Xi * Hvi ) / Z
=
15/0°C
at 101.325 kPa
=
54.44
MJ / kg
=
44.06
MJ / m3
=
55.69
MJ / m3
at 101.325 kPa
WOBBE INDEX
15/0°C at
101.325 kPa
=
Hv / √
Σ ( Xi * Mi ) 28.96
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
= = =
*
WOBBE INDEX
1 Z
15/0°C at
101.325 kPa
-160.2 °C -128.5 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
404.978 m3 136,292.944 m3 135,887.966 m3
5. ENERGY DELIVERED GROSS QUANTITY DELIVERED
=
VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED)
GROSS DELIVERED QUANTITY
=
3,396,251,049
GROSS DELIVERED QUANTITY
=
3,219,024
GROSS DELIVERED QUANTITY
=
943,403,069
MJ MMBTU KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.S.O. 6578 (1991). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 7
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000 0.0000
16.043 30.070 44.097 58.123 58.123 72.150 72.150 86.177 28.013 44.010 31.9988
0.038123 0.047925 0.062479 0.078332 0.076856 0.091699 0.091562 0.104868 0.046900 ----0.031474
55.58 51.950 50.37 49.39 49.55 48.95 49.05 48.72 0 0 0
2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.08
WITH C = K1 +
kg/m3 at -160.2 °C
( K2 - K1 ) * Xn 0.04 K1 = 0.00042
K2 = 0.00068
3. HIGHER HEATING VALUES Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
=
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi )
=
1.13285 * Σ ( Xi * Mi * Hi )
Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
at 14.696 PSIA
=
54.4361
=
1115.3
BTU / SCF
=
1411.4
BTU / SCF
at 14.696 PSIA
WOBBE INDEX
60/60°F at
14.696 PSIA
=
Hv / √
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
60/60°F at
14.696 PSIA
-160.2 °C -128.5 °C 116.6 kPa
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
MJ / kg
405 m3 136,293 m3 135,888 m3
5. ENERGY DELIVERED GROSS QUANTITY DELIVERED
=
VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED)
GROSS DELIVERED QUANTITY
=
3,395,912,432
GROSS DELIVERED QUANTITY
=
3,218,703
GROSS DELIVERED QUANTITY
=
943,309,009
MJ MMBTU KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.P. PART XII (1998). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 SI (2000).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 8
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000
16.043 30.070 44.097 58.123 58.123 72.150 72.150 86.177 28.013 44.010
0.038122 0.047925 0.062479 0.078332 0.076857 0.091699 0.091562 0.104877 0.046866 0.027180
55.575 51.950 50.37 49.39 49.55 48.95 49.05 48.72 0 0
2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.08
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.2 °C
K1 = 0.000419
K2 = 0.000685
3. HIGHER HEATING VALUES Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
=
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi )
=
1.13285 * Σ ( Xi * Mi * Hi )
Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
at 14.696 PSIA
=
54.4361
=
1115.3
BTU / SCF
=
1411.4
BTU / SCF
at 14.696 PSIA
WOBBE INDEX
60/60°F at
14.696 PSIA
Hv / √
=
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
60/60°F at
14.696 PSIA
-160.2 °C -128 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
MJ / kg
404.978 m3 136,292.944 m3 135,887.000 m3
5. ENERGY DELIVERED Q
=
( V * D * Hm - DV ) / 1055.12
With DV
=
V *
288.15 ( 273.15 + Tv )
*
Pa 1013.25
*
37.7 * C
C = ( 0.5 )
GROSS QUANTITY
=
3,395,694,333
MJ
or
3,218,485
MMBTU
or
943,248,426
KWH
ENERGY DISPLACED
=
5,851,242
MJ
or
5,546
MMBTU
or
1,625,345
KWH
NET QUANTITY
=
3,389,843,091
MJ
or
3,212,940
MMBTU
or
941,623,081
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. INTERAGENCY REPORT 77-867. THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 SI (1992).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 9
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000 0.0000
16.043 30.070 44.097 58.123 58.123 72.150 72.150 86.177 28.013 44.010 31.9988
0.038123 0.047925 0.062479 0.078332 0.076856 0.091699 0.091562 0.104868 0.046900 0.027183 0.031474
55.58 51.950 50.37 49.39 49.55 48.95 49.05 48.72 0 0 0
METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN 2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.11
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.2 °C
K1 = 0.000423
K2 = 0.000682
3. HIGHER HEATING VALUES Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
=
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi )
=
1.13285 * Σ ( Xi * Mi * Hi )
Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
at 14.696 PSIA
=
54.4361
=
1115.3
BTU / SCF
=
1411.4
BTU / SCF
at 14.696 PSIA
WOBBE INDEX
60/60°F at
14.696 PSIA
Hv / √
=
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
60/60°F at
14.696 PSIA
-160.2 °C -128.5 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
MJ / kg
404.978 m3 136,292.944 m3 135,887.000 m3
5. ENERGY DELIVERED Q
=
( V * D * Hm - Qr ) / 1055.12
With Qr
=
V *
288.15 ( 273.15 + Tv )
*
Pa 1013.25
*
37.707 (Ideal Gas)
GROSS QUANTITY
=
3,395,916,235
MJ
or
3,218,695
MMBTU
or
943,310,065
KWH
ENERGY DISPLACED
=
11,745,116
MJ
or
11,132
MMBTU
or
3,262,532
KWH
NET QUANTITY
=
3,384,171,119
MJ
or
3,207,560
MMBTU
or
940,047,533
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.P. PART XII (1998). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 (2000).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 10
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000 0.0000
16.043 30.070 44.097 58.123 58.123 72.150 72.150 86.177 28.013 44.010 31.9988
0.038123 0.047925 0.062479 0.078332 0.076856 0.091699 0.091562 0.104868 0.046900 0.027183 0.031474
55.58 51.950 50.37 49.39 49.55 48.95 49.05 48.72 0 0 0
2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.11
WITH C = K1 +
kg/m3 at -160.2 °C
( K2 - K1 ) * Xn 0.04 K1 = 0.000423
K2 = 0.000682
3. HIGHER HEATING VALUES Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
=
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi )
=
1.13285 * Σ ( Xi * Mi * Hi )
Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
at 14.696 PSIA
=
54.4361
=
1115.3
BTU / SCF
=
1411.4
BTU / SCF
at 14.696 PSIA
WOBBE INDEX
60/60°F at
14.696 PSIA
=
Hv / √
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
60/60°F at
14.696 PSIA
-160.2 °C -128.5 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
MJ / kg
404.978 m3 136,292.944 m3 135,887.000 m3
5. ENERGY DELIVERED GROSS QUANTITY DELIVERED
=
VOLUME * DENSITY * HHV (MASS BASED) / 1055.12
GROSS DELIVERED QUANTITY
=
3,395,911,071
GROSS DELIVERED QUANTITY
=
3,218,690
GROSS DELIVERED QUANTITY
=
943,308,631
MJ MMBTU KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.P. PART XII (1998). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 (2000).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 11
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000 0.0000
16.042 30.069 44.096 58.122 58.122 72.149 72.149 86.175 28.013 44.010 31.9990
0.038123 0.047925 0.062479 0.078332 0.076856 0.091699 0.091562 0.104868 0.046900 0.027183 0.031474
55.58 51.952 50.370 49.39 49.55 48.950 49.05 48.72 0 0 0
2. DENSITY CALCULATIONS DENSITY
=
DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
459.082
WITH C = K1 +
kg/m3 at -160.2 °C
( K2 - K1 ) * Xn 0.04 K1 = 0.000423
K2 = 0.000682
3. HIGHER HEATING VALUES Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
=
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi )
=
1.13285 * Σ ( Xi * Mi * Hi )
Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
at 14.696 PSIA
=
54.4372
=
1115.2
BTU / SCF
=
1411.3
BTU / SCF
at 14.696 PSIA
WOBBE INDEX
60/60°F at
14.696 PSIA
=
Hv / √
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
60/60°F at
14.696 PSIA
-160.2 °C -128.5 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
MJ / kg
404.978 m3 136,292.944 m3 135,888.000 m3
5. ENERGY DELIVERED GROSS QUANTITY DELIVERED
=
VOLUME * DENSITY * HHV (MASS BASED) / 1055.12
GROSS DELIVERED QUANTITY
=
3,395,805,565
GROSS DELIVERED QUANTITY
=
3,218,590
GROSS DELIVERED QUANTITY
=
943,279,324
MJ MMBTU KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.S.O. 6578 (1991). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 (2003).
Mohamed-Hamid BOUABDELLI FOR INTERTEK SPA Contract # 12
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000 0.0000
16.043 30.070 44.097 58.123 58.123 72.150 72.150 86.177 28.013 44.010 31.9988
0.038123 0.047925 0.062479 0.078332 0.076856 0.091699 0.091562 0.104868 0.046900 0.027183 0.031474
55.58 51.950 50.37 49.39 49.55 48.95 49.05 48.72 0 0 0
METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN 2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.11
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.2 °C
K1 = 0.000423
K2 = 0.000682
3. HIGHER HEATING VALUES Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
=
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi )
=
1.13285 * Σ ( Xi * Mi * Hi )
Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
at 14.696 PSIA
=
54.4361
=
1115.3
BTU / SCF
=
1411.4
BTU / SCF
at 14.696 PSIA
WOBBE INDEX
60/60°F at
14.696 PSIA
Hv / √
=
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
60/60°F at
14.696 PSIA
-160.2 °C -128.5 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
MJ / kg
404.978 m3 136,292.944 m3 135,887.000 m3
5. ENERGY DELIVERED Q
=
( V * D * Hm - Qr ) / 1055.12
With Qr
=
V *
288.15 ( 273.15 + Tv )
*
Pa 1013.25
*
37.707 * 0.50
GROSS QUANTITY
=
3,395,916,235
MJ
or
3,218,695
MMBTU
or
943,310,065
KWH
ENERGY DISPLACED
=
5,872,558
MJ
or
5,566
MMBTU
or
1,631,266
KWH
NET QUANTITY
=
3,390,043,677
MJ
or
3,213,120
MMBTU
or
941,678,799
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.P. PART XII (1998). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 (2000).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 13
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000 0.0000
16.043 30.070 44.097 58.123 58.123 72.150 72.150 86.177 28.013 44.010 31.999
0.038122 0.047925 0.062479 0.078332 0.076857 0.091699 0.091562 0.104877 0.046866 0.027180 0.031474
55.58 51.95 50.37 49.39 49.55 48.95 49.05 48.72 0 0 0
METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN 2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.08
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.2 °C
K1 = 0.000419
K2 = 0.000685
3. HIGHER HEATING VALUES Hm (MASS)
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi )
=
15°C
Hv (VOLUME) 60/60°F
Hm (MASS) 15°C
Hv (VOLUME)
Σ ( Xi * Mi * Hi) * 1.13285
=
60/60°F
at 14.696 psia
=
54.4361
=
1115
BTU / SCF
=
1411
BTU / SCF
at 14.696 psia
WOBBE INDEX
60/60°F at
14.696 psia
Hv / √
=
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING 5. ENERGY DELIVERED V * D * Hm - Qr QUANTITY = 1055.12
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
60/60°F at
14.696 psia
-160.2 °C -128.5 °C 1166 mbar
WITH
Qr
=
V *
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
288.15 ( 273.15 + Tv )
*
Pa 1013.25
= = =
*
MJ / kg
404.978 m3 136,292.944 m3 135,888.000 m3
37.7 (Ideal Gas)
GROSS QUANTITY
=
3,395,719,322
MJ
or
3,218,508
MMBTU
or
943,255,367
KWH
ENERGY DISPLACED
=
11,743,022
MJ
or
11,130
MMBTU
or
3,261,951
KWH
NET QUANTITY
=
3,383,978,343
MJ
or
3,207,380
MMBTU
or
939,993,417
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. INTERAGENCY REPORT 77-867. THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO G.P.A. 2145 SI (1989).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 14
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000 0.0000
16.043 30.070 44.097 58.123 58.123 72.150 72.150 86.177 28.013 44.010 31.999
0.038122 0.047925 0.062479 0.078332 0.076857 0.091699 0.091562 0.104877 0.046866 0.027180 0.031474
55.58 51.95 50.37 49.39 49.55 48.95 49.05 48.72 0 0 0
2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.08
WITH C = K1 +
kg/m3 at -160.2 °C
( K2 - K1 ) * Xn 0.04 K1 = 0.000419
K2 = 0.000685
3. HIGHER HEATING VALUES Hm (MASS)
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi )
=
15°C
Hv (VOLUME) 60/60°F
=
Hm (MASS) 15°C
Hv (VOLUME)
Σ ( Xi * Mi * Hi) * 1.13285
60/60°F
at 14.696 psia
=
54.4361
=
1115
BTU / SCF
=
1411
BTU / SCF
at 14.696 psia
WOBBE INDEX
60/60°F at
14.696 psia
=
Hv / √
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
60/60°F at
14.696 psia
-160.2 °C -128.5 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
MJ / kg
404.978 m3 136,292.944 m3 135,888.000 m3
5. ENERGY DELIVERED GROSS QUANTITY DELIVERED
=
VOLUME * DENSITY * HIGHER HEATING VALUE (MASS BASED) / 1055.12
GROSS DELIVERED QUANTITY
=
3,395,721,161
GROSS DELIVERED QUANTITY
=
3,218,510
GROSS DELIVERED QUANTITY
=
943,255,878
MJ MMBTU KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. INTERAGENCY REPORT 77-867. THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO G.P.A. 2145 SI (1996).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 15
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000 0.0000
16.043 30.070 44.097 58.123 58.123 72.150 72.150 86.177 28.013 44.010 31.9988
0.038123 0.047925 0.062479 0.078332 0.076856 0.091699 0.091562 0.104868 0.046900 ----0.031474
55.58 51.950 50.37 49.39 49.55 48.95 49.05 48.72 0 0 0
2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.08
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.2 °C
K1 = 0.00042
K2 = 0.00068
3. HIGHER HEATING VALUES Hm (MASS)
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi ) Σ ( Xi * Mi * Hi ) * 101.325 8.314510 * 288.15
=
15°C
Hv (VOLUME) 15/15°C
=
at 101.325 kPa
WOBBE INDEX
15/15°C at
101.325 kPa
Hv / √
=
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
Hm (MASS) 15°C
Hv (VOLUME) 15/15°C
54.4361
MJ / kg
=
41.6362
MJ / m3
=
52.6900
MJ / m3
at 101.325 kPa
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
=
15/15°C at
101.325 kPa
-160.2 °C -128.5 °C 116.6 kPa
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
405 m3 136,293 m3 135,888 m3
5. ENERGY DELIVERED QUANTITY
=
V * D * Hm - Qr
WITH
Qr
=
V *
288.15 ( 273.15 + Tv )
*
Pa 101.33
*
37.707 (Ideal Gas)
GROSS QUANTITY
=
3,395,912,432
MJ
or
3,218,703
MMBTU
or
943,309,009
KWH
ENERGY DISPLACED
=
11,745,871
MJ
or
11,133
MMBTU
or
3,262,742
KWH
NET QUANTITY
=
3,384,166,561
MJ
or
3,207,570
MMBTU
or
940,046,267
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.P. PART XII (1998). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO GPA 2145 (2000).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 16
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000 0.0000
16.043 30.070 44.097 58.123 58.123 72.150 72.150 86.177 28.0135 44.010 31.9988
0.038123 0.047925 0.062479 0.078332 0.076856 0.091699 0.091562 0.104868 0.046900 0.027192 0.031474
55.574 51.950 50.37 49.39 49.55 48.95 49.04 48.75 0 0 0
METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN 2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.11
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.2 °C
K1 = 0.000423
K2 = 0.000682
3. HIGHER HEATING VALUES Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
=
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi )
=
1.13285 * Σ ( Xi * Mi * Hi )
Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
at 14.696 PSIA
=
54.4355
=
1115
BTU / SCF
=
1411
BTU / SCF
at 14.696 PSIA
WOBBE INDEX
60/60°F at
14.696 PSIA
Hv / √
=
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
60/60°F at
14.696 PSIA
-160.2 °C -128.5 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
MJ / kg
404.978 m3 136,292.944 m3 135,888.000 m3
5. ENERGY DELIVERED Q
=
( V * D * Hm - Qr ) / 1055.12
With Qr
=
V *
273.15 ( 273.15 + Tv )
*
Pa 1013.25
*
39.78 (Ideal Gas)
GROSS QUANTITY
=
3,395,903,795
MJ
or
3,218,683
MMBTU
or
943,306,610
KWH
ENERGY DISPLACED
=
11,745,889
MJ
or
11,133
MMBTU
or
3,262,747
KWH
NET QUANTITY
=
3,384,157,906
MJ
or
3,207,550
MMBTU
or
940,043,863
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.S.O. 6578 (1991). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 17
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmole (Mi)
MOLAR VOL. m3 / kmole (Vi)
MOLAR HHV MJ / kg (Hi)
0.9024 0.0595 0.0224 0.0069 0.0058 0.0002 0.0000 0.0000 0.0028 0.0000 0.0000
16.043 30.070 44.097 58.124 58.124 72.151 72.151 86.178 28.013 44.010 31.999
0.038122 0.047925 0.062479 0.078332 0.076857 0.091699 0.091562 0.104877 0.046866 0.027180 0.031474
55.560 51.926 50.39 49.4 49.54 48.94 49.05 48.72 0 0 0
METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN CARBON DIOXIDE OXYGEN 2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.08
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.2 °C
K1 = 0.000419
K2 = 0.000685
3. HIGHER HEATING VALUES Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
=
Σ ( Xi * Mi * Hi ) Σ ( Xi * Mi )
=
1.13285 * Σ ( Xi * Mi * Hi )
Hm (MASS) 15°C
Hv (VOLUME) 60/60°F
at 14.696 PSIA
=
54.4233
=
1115
BTU / SCF
=
1411
BTU / SCF
at 14.696 PSIA
WOBBE INDEX
60/60°F at
14.696 PSIA
Hv / √
=
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
60/60°F at
14.696 PSIA
-160.2 °C -128.5 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
MJ / kg
404.978 m3 136,292.944 m3 135,888.000 m3
5. ENERGY DELIVERED Q
=
( V * D * Hm - Qr ) / 1055.12
With Qr
=
V *
288.15 ( 273.15 + Tv )
*
Pa 1013.25
*
37.7 (Ideal Gas)
GROSS QUANTITY
=
3,394,920,859
MJ
or
3,217,751
MMBTU
or
943,033,572
KWH
ENERGY DISPLACED
=
11,743,022
MJ
or
11,130
MMBTU
or
3,261,951
KWH
NET QUANTITY
=
3,383,177,837
MJ
or
3,206,621
MMBTU
or
939,771,621
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON N.B.S. INTERAGENCY REPORT 77-867. THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.P. 251/76.
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 18
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
REPORT OF CALCULATIONS VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. COMPOSITION FACTORS COMPONENTS
MOLAR FRACTION (Xi)
MOLAR WT. kg / kmol (Mi)
MOLAR VOL. m3 / kmol (Vi)
MOLAR HHV MJ / kmol (Hi)
METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE N-HEXANE NITROGEN OXYGEN
0.902400 0.059500 0.022400 0.006900 0.005800 0.000200 0.000000 0.000000 0.002800 0.000000
16.043 30.070 44.097 58.123 58.123 72.150 72.150 86.177 28.014 31.999
0.038123 0.047925 0.062479 0.078332 0.076856 0.091699 0.091562 0.104868 0.046900 0.031474
891.56 1562.14 2221.1 2870.58 2879.76 3531.68 3538.6 4198.24 0 0
2. DENSITY CALCULATIONS DENSITY
=
Σ ( Xi * Mi ) Σ ( Xi * Vi ) - Xm * C
DENSITY
=
459.10
( K2 - K1 ) * Xn 0.04
WITH C = K1 +
kg/m3 at -160.2 °C
K1 = 0.000423
K2 = 0.000682
3. HIGHER HEATING VALUES Hm (MASS)
Σ ( Xi * Hi ) Σ ( Xi * Mi ) Σ ( Xi * Hi ) * 101.325 8.314510 * 288.15
=
15°C
Hv (VOLUME) 15/15°C
=
at 101.325 kPa
WOBBE INDEX
15/15°C at
101.325 kPa
Hv / √
=
4. QUANTITIES DELIVERED LIQUID TEMPERATURE AFTER LOADING VAPOR TEMPERATURE BEFORE LOADING ABSOLUTE PRESSURE BEFORE LOADING
Hm (MASS) 15°C
Hv (VOLUME) 15/15°C
54.4346
MJ / kg
=
41.6351
MJ / m3
=
52.6886
MJ / m3
at 101.325 kPa
WOBBE INDEX
Σ ( Xi * Mi ) 28.96
= = =
=
15/15°C at
101.325 kPa
-160.2 °C -128.0 °C 1166 mbar
VESSEL O.C.T. VOLUME VESSEL C.C.T. VOLUME LOADED VOLUME
= = =
404.978 m3 136,292.944 m3 135,888.000 m3
5. ENERGY DELIVERED QUANTITY
=
V * D * Hm - Qr
WITH
Qr
=
V *
( 273.15 + 15 ) ( 273.15 + Tv )
*
Pa 1013.25
*
37.7 (Ideal Gas)
GROSS QUANTITY
=
3,395,968,923
MJ
or
3,218,745
MMBTU
or
943,324,701
KWH
ENERGY DISPLACED
=
11,703,236
MJ
or
11,092
MMBTU
or
3,250,899
KWH
NET QUANTITY
=
3,384,265,686
MJ
or
3,207,650
MMBTU
or
940,073,802
KWH
6. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 15°C. THE DENSITY CALCULATION (REVISED KLOSEK-MCKINLEY METHOD) IS BASED ON I.S.O. 6578 (1991). THE HIGHER HEATING VALUES AND QUANTITY OF ENERGY DELIVERED IS DETERMINED ACCORDING TO I.S.O. 6976 (1995).
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT SPA Contract # 19
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
OPENING CUSTODY TRANSFER VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
1. OPENING CUSTODY TRANSFER MEASUREMENTS TANK NAME 1 2 SYSTEM TYPE PRIMARY PRIMARY 1ST READING m 0.035 0.033 2ND READING m 0.035 0.032 3RD READING m 0.035 0.032 4TH READING m 0.035 0.033 5TH READING m 0.035 0.032 AVG. GAUGE m 0.035 0.032 DENSITY CORR. m 0.000 0.000 TEMP. CORR. m 0.000 0.000 TRIM CORR. m -0.003 -0.004 LIST CORR. m 0.007 0.010 CORR. GAUGE m 0.039 0.038
3 PRIMARY 0.033 0.033 0.033 0.033 0.032 0.033 0.000 0.000 -0.004 0.010 0.039
4 PRIMARY 0.287 0.297 0.290 0.290 0.290 0.291 0.000 0.000 -0.011 0.000 0.280
2. OPENING CUSTODY TRANSFER TEMPERATURES TANK NAME 1 2 TEMP PROBE #1 °C -119.60 V -123.00 V TEMP PROBE #2 °C -127.10 V -126.90 V TEMP PROBE #3 °C -129.60 V -129.00 V TEMP PROBE #4 °C -132.40 V -131.40 V TEMP PROBE #5 °C -133.10 V -131.90 V TEMP PROBE #6 °C -143.20 L -141.50 L
3 -123.10 V -127.20 V -129.10 V -131.80 V -132.30 V -142.20 L
4 -118.20 V -125.40 V -129.00 V -133.60 V -136.10 V -157.90 L
TANK AVERAGE °C -128.36 V -128.44 V -128.70 V TANK AVERAGE °C -143.20 L -141.50 L -142.20 L AVERAGE VAPOR TEMPERATURE = -128.5 °C 3. OPENING CUSTODY TRANSFER PRESSURES TANK NAME 1 2 PRESSURE 1166 1166 AVERAGE TANK PRESSURE = 1166 4. OPENING CUSTODY TRANSFER VOLUMES TANK NAME 1 2 TANK VOLUME m3 21.371 37.771 THERMAL CORR. 1.000000 1.000000 CORR. VOLUME m3 21.371 37.771
3 1166 mbar
TRIM LIST
: 10:28
-146.2 °C
4 1166 ATMOSPHERIC PRESSURE =
3 38.761 1.000000 38.761
= =
TIME
-128.46 V -157.90 L AVERAGE LIQUID TEMPERATURE =
998
mbar
4 307.075 1.000000 307.075
OPENING CUSTODY TRANSFER VOLUME =
5. ADDITION INFORMATION AND COMMENTS FWD DRAFT = 9.60 m AFT DRAFT = 9.78 m
: 4-Aug-2009
0.18 m 0.21 °P
404.978
CUBIC METERS
VESSEL DECK LINES
=
EMPTY
Mohamed-Hamid BOUABDELLI FOR INTERTEK Arrival Inspection
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
AFTER GAS-UP MEASUREMENT VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
1. OPENING CUSTODY TRANSFER MEASUREMENTS TANK NAME 1 2 SYSTEM TYPE PRIMARY PRIMARY 1ST READING m 0.000 0.000 2ND READING m 0.000 0.000 3RD READING m 0.000 0.000 4TH READING m 0.000 0.000 5TH READING m 0.000 0.000 AVG. GAUGE m 0.000 0.000 DENSITY CORR. m 0.000 0.000 TEMP. CORR. m 0.000 0.000 TRIM CORR. m 0.000 0.000 LIST CORR. m 0.000 0.000 CORR. GAUGE m 0.000 0.000
3 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
4 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
3 23.99 V 23.67 V 23.63 V 23.64 V 23.52 V
4 25.22 V 25.10 V 25.13 V 24.99 V 24.90 V
TANK AVERAGE °C 23.88 V 23.53 V 23.69 V TANK AVERAGE °C AVERAGE VAPOR TEMPERATURE = 24.0 °C
25.07 V
2. OPENING CUSTODY TRANSFER TEMPERATURES TANK NAME 1 2 TEMP PROBE #1 °C 24.02 V 23.77 V TEMP PROBE #2 °C 23.91 V 23.52 V TEMP PROBE #3 °C 23.93 V 23.50 V TEMP PROBE #4 °C 23.80 V 23.49 V TEMP PROBE #5 °C 23.74 V 23.37 V TEMP PROBE #6 °C
3. OPENING CUSTODY TRANSFER PRESSURES TANK NAME 1 2 PRESSURE 1172 1171 AVERAGE TANK PRESSURE = 1171 4. OPENING CUSTODY TRANSFER VOLUMES TANK NAME 1 2 TANK VOLUME m3 0.000 0.000 THERMAL CORR. 1.000000 1.000000 CORR. VOLUME m3 0.000 0.000
3 1172 mbar
TRIM LIST
: 03:05
°C
4 1169 ATMOSPHERIC PRESSURE =
3 0.000 1.000000 0.000
= =
TIME
AVERAGE LIQUID TEMPERATURE =
1008
mbar
4 0.000 1.000000 0.000
OPENING CUSTODY TRANSFER VOLUME =
5. ADDITION INFORMATION AND COMMENTS FWD DRAFT = 9.00 m AFT DRAFT = 9.20 m
: 7-Aug-2009
0.20 m 0.00
0.000
CUBIC METERS
VESSEL DECK LINES
=
EMPTY
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT After Gas Up Inspection
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
AFTER COOL-DOWN MEASUREMENT VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
1. AFTER COOL DOWN MEASUREMENTS TANK NAME 1 2 SYSTEM TYPE PRIMARY PRIMARY 1ST READING m 0.069 0.027 2ND READING m 0.069 0.027 3RD READING m 0.069 0.027 4TH READING m 0.069 0.027 5TH READING m 0.069 0.027 AVG. GAUGE m 0.069 0.027 DENSITY CORR. m 0.000 0.000 TEMP. CORR. m 0.000 0.000 TRIM CORR. m -0.004 -0.003 LIST CORR. m 0.005 0.010 CORR. GAUGE m 0.070 0.034
3 PRIMARY 0.042 0.042 0.042 0.042 0.042 0.042 0.000 0.000 -0.005 0.009 0.046
4 PRIMARY 0.044 0.044 0.044 0.044 0.044 0.044 0.000 0.000 -0.004 0.006 0.046
2. AFTER COOL DOWN TEMPERATURES TANK NAME 1 2 TEMP PROBE #1 °C -122.00 V -119.20 V TEMP PROBE #2 °C -124.20 V -122.00 V TEMP PROBE #3 °C -125.70 V -124.50 V TEMP PROBE #4 °C -127.70 V -126.30 V TEMP PROBE #5 °C -127.70 V -126.90 V TEMP PROBE #6 °C -158.50 L -155.10 L
3 -118.90 V -121.90 V -124.60 V -126.60 V -127.60 V -158.30 L
4 -119.40 V -122.30 V -124.70 V -126.60 V -126.90 V -158.80 L
TANK AVERAGE °C -125.46 V -123.78 V -123.92 V TANK AVERAGE °C -158.50 L -155.10 L -158.30 L AVERAGE VAPOR TEMPERATURE = -124.3 °C 3. AFTER COOL DOWN PRESSURES TANK NAME 1 PRESSURE 1069 AVERAGE TANK PRESSURE = 4. AFTER COOL DOWN VOLUMES TANK NAME 1 TANK VOLUME m3 47.856 THERMAL CORR. 1.000000 CORR. VOLUME m3 47.856
2 1070 1069.75
2 44.726 1.000000 44.726
3 1070 mbar
TRIM LIST
: 12:03
-157.7 °C
4 1070 ATMOSPHERIC PRESSURE =
3 60.576 1.000000 60.576
= =
TIME
-123.98 V -158.80 L AVERAGE LIQUID TEMPERATURE =
998
mbar
4 59.168 1.000000 59.168
AFTER COOL DOWN VOLUME =
5. ADDITION INFORMATION AND COMMENTS FWD DRAFT = 9.45 m AFT DRAFT = 9.61 m Data from Snapshot CTS
: 7-Aug-2009
0.16 m 0.15 °P
212.326
CUBIC METERS
VESSEL DECK LINES
=
EMPTY
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT After Cool Down Inspection
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
CLOSING CUSTODY TRANSFER VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
1. CLOSING CUSTODY TRANSFER MEASUREMENTS TANK NAME 1 2 SYSTEM TYPE PRIMARY PRIMARY 1ST READING m 26.360 26.236 2ND READING m 26.355 26.250 3RD READING m 26.385 26.243 4TH READING m 26.355 26.254 5TH READING m 26.393 26.250 AVG. GAUGE m 26.370 26.247 DENSITY CORR. m 0.000 0.000 TEMP. CORR. m 0.000 0.000 TRIM CORR. m -0.030 -0.042 LIST CORR. m 0.000 0.001 CORR. GAUGE m 26.340 26.206
3 PRIMARY 26.257 26.241 26.242 26.236 26.248 26.245 0.000 0.000 -0.042 0.000 26.203
4 PRIMARY 26.232 26.251 26.243 26.243 26.237 26.241 0.000 0.000 -0.036 0.000 26.205
2. CLOSING CUSTODY TRANSFER TEMPERATURES TANK NAME 1 2 TEMP PROBE #1 °C -145.40 V -155.00 V TEMP PROBE #2 °C -160.20 L -160.20 L TEMP PROBE #3 °C -160.20 L -160.30 L TEMP PROBE #4 °C -160.20 L -160.30 L TEMP PROBE #5 °C -160.20 L -160.20 L TEMP PROBE #6 °C -160.30 L -160.30 L
3 -155.10 V -160.20 L -160.20 L -160.30 L -160.20 L -160.20 L
4 -152.40 V -160.30 L -160.30 L -160.20 L -160.20 L -160.30 L
TANK AVERAGE °C -145.40 V -155.00 V -155.10 V TANK AVERAGE °C -160.22 L -160.26 L -160.22 L AVERAGE VAPOR TEMPERATURE = -152.0 °C 3. CLOSING CUSTODY TRANSFER PRESSURES TANK NAME 1 2 PRESSURE 1101 1101 AVERAGE TANK PRESSURE = 1101.5 4. CLOSING CUSTODY TRANSFER VOLUMES TANK NAME 1 2 TANK VOLUME m3 24,159.419 38,797.660 THERMAL CORR. 1.000000 1.000000 CORR. VOLUME m3 24,159.419 38,797.660
3 1102 mbar
3 38,818.221 1.000000 38,818.221
CLOSING CUSTODY TRANSFER VOLUME =
: 5-Aug-2009
TIME
-152.40 V -160.26 L AVERAGE LIQUID TEMPERATURE =
: 04:17
-160.2 °C
4 1102 ATMOSPHERIC PRESSURE =
990
mbar
4 34,517.644 1.000000 34,517.644
136,292.944
CUBIC METERS
5. ADDITION INFORMATION AND COMMENTS FWD DRAFT = 11.45 m TRIM = 0.05 m VESSEL DECK LINES AFT DRAFT = 11.50 m LIST = 0.34 °P SAMPLES FOR OMAN LNG TESTING WERE SEALED (# 046725 / # 046769 SAMPLES FOR OMAN LNG RETAIN WERE SEALED (# 046797 / # 046736) SAMPLES FOR SHIP SEALED (# 046707 / # 046761) DRY LINES OF GC WERE DONE BEFORE START FIRST STANDARD GAS INJECTION
=
FULL
Mohamed-Hamid BOUABDELLI FOR INTERTEK Departure Inspection
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
SECONDARY CUSTODY TRANSFER VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
1. OPENING SECONDARY CUSTODY TRANSFER MEASUREMENTS TANK NAME 1 2 3 1ST READING m 0.039 0.037 0.039 2ND READING m 0.035 0.038 0.037 3RD READING m 0.040 0.038 0.037 4TH READING m 0.039 0.036 0.037 5TH READING m 0.039 0.036 0.039 AVG. GAUGE m 0.038 0.037 0.038 DENSITY CORR. m 0.000 0.000 0.000 TEMP. CORR. m 0.000 0.000 0.000 TRIM CORR. m -0.004 -0.004 -0.005 LIST CORR. m 0.009 0.012 0.012 CORR. GAUGE m 0.043 0.045 0.045 2. OPENING SECONDARY CUSTODY TRANSFER VOLUMES TANK NAME 1 2 3 TANK VOLUME m3 23.611 44.882 44.875 THERMAL CORR. 1.000000 1.000000 1.000000 CORR. VOLUME m3 23.611 44.882 44.875 OPENING SECONDARY CUSTODY TRANSFER VOLUME = OPENING CUSTODY TRANSFER VOLUME = DIFFERENCE = 3. CLOSING SECONDARY CUSTODY TRANSFER MEASUREMENTS TANK NAME 1 2 3 1ST READING m 26.366 26.249 26.250 2ND READING m 26.367 26.256 26.253 3RD READING m 26.372 26.254 26.249 4TH READING m 26.368 26.253 26.248 5TH READING m 26.369 26.250 26.248 AVG. GAUGE m 26.368 26.252 26.250 DENSITY CORR. m 0.000 0.000 0.000 TEMP. CORR. m 0.000 0.000 0.000 TRIM CORR. m -0.035 -0.047 -0.047 LIST CORR. m 0.005 0.005 0.005 CORR. GAUGE m 26.338 26.210 26.208 4. CLOSING SECONDARY CUSTODY TRANSFER VOLUMES TANK NAME 1 2 3 TANK VOLUME m3 24,157.993 38,801.440 38,822.552 THERMAL CORR. 1.000000 1.000000 1.000000 CORR. VOLUME m3 24,157.993 38,801.440 38,822.552 CLOSING SECONDARY CUSTODY TRANSFER VOLUME = CLOSING CUSTODY TRANSFER VOLUME = DIFFERENCE =
:
4-Aug-2009
TO
5-Aug-2009
4 0.289 0.290 0.290 0.295 0.295 0.292 0.000 0.000 -0.012 0.003 0.283
4 310.528 1.000000 310.528 423.896 CUBIC METERS 404.978 CUBIC METERS 18.918 CUBIC METERS
4 26.254 26.256 26.256 26.256 26.255 26.255 0.000 0.000 -0.044 0.005 26.216
4 34,526.897 1.000000 34,526.897 136,308.882 CUBIC METERS 136,292.944 CUBIC METERS 15.938 CUBIC METERS
5. ADDITION INFORMATION AND COMMENTS SEA CONDITION : ROLLING
Mohamed-Hamid BOUABDELLI FOR INTERTEK
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
VESSEL MEASUREMENT - REFERENCE ONLY VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN 1. VESSEL TANK MEASUREMENTS TANK NAME 1 SYSTEM TYPE PRIMARY 1ST READING m 0.000 2ND READING m 0.000 3RD READING m 0.000 4TH READING m 0.000 5TH READING m 0.000 AVG. GAUGE m 0.000 DENSITY CORR. m 0.000 TEMP. CORR. m 0.000 TRIM CORR. m 0.000 LIST CORR. m 0.000 CORR. GAUGE m 0.000
DATE
2 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
3 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
4 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
2 30.08 V 29.78 V 29.25 V 29.26 V 29.12 V
3 29.44 V 29.18 V 28.80 V 28.67 V 28.65 V
4 29.70 V 29.61 V 29.48 V 29.48 V 29.33 V
TANK AVERAGE °C 29.26 V 29.50 V 28.95 V TANK AVERAGE °C AVERAGE VAPOR TEMPERATURE = 29.3 °C
29.52 V
2. VESSEL TANK TEMPERATURES TANK NAME 1 TEMP PROBE #1 °C 29.76 V TEMP PROBE #2 °C 29.46 V TEMP PROBE #3 °C 29.08 V TEMP PROBE #4 °C 29.28 V TEMP PROBE #5 °C 28.71 V TEMP PROBE #6 °C
3. VESSEL TANK PRESSURES TANK NAME 1 PRESSURE 1106 AVERAGE TANK PRESSURE = 4. VESSEL TANK VOLUMES TANK NAME 1 TANK VOLUME m3 0.000 THERMAL CORR. 1.000000 CORR. VOLUME m3 0.000
2 1107 1106.5
2 0.000 1.000000 0.000
3 1106 mbar
TRIM LIST
: 06:07
°C
4 1107 ATMOSPHERIC PRESSURE =
3 0.000 1.000000 0.000
= =
TIME
AVERAGE LIQUID TEMPERATURE =
992
mbar
4 0.000 1.000000 0.000
VESSEL VOLUME =
5. ADDITION INFORMATION AND COMMENTS FWD DRAFT = 9.00 m AFT DRAFT = 9.02 m
: 5-Jun-2007
0.02 m 0.02 °S
0.000
CUBIC METERS
VESSEL DECK LINES
=
EMPTY
ABDELOUAHEB ZENNIR FOR INTERTEK Vessel Measurement 1
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
VESSEL MEASUREMENT - REFERENCE ONLY VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN 1. VESSEL TANK MEASUREMENTS TANK NAME 1 SYSTEM TYPE PRIMARY 1ST READING m 0.000 2ND READING m 0.000 3RD READING m 0.000 4TH READING m 0.000 5TH READING m 0.000 AVG. GAUGE m 0.000 DENSITY CORR. m 0.000 TEMP. CORR. m 0.000 TRIM CORR. m 0.000 LIST CORR. m 0.000 CORR. GAUGE m 0.000
DATE
2 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
3 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
4 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
2 30.08 V 29.78 V 29.25 V 29.26 V 29.12 V
3 29.44 V 29.18 V 28.80 V 28.67 V 28.65 V
4 29.70 V 29.61 V 29.48 V 29.48 V 29.33 V
TANK AVERAGE °C 29.26 V 29.50 V 28.95 V TANK AVERAGE °C AVERAGE VAPOR TEMPERATURE = 29.3 °C
29.52 V
2. VESSEL TANK TEMPERATURES TANK NAME 1 TEMP PROBE #1 °C 29.76 V TEMP PROBE #2 °C 29.46 V TEMP PROBE #3 °C 29.08 V TEMP PROBE #4 °C 29.28 V TEMP PROBE #5 °C 28.71 V TEMP PROBE #6 °C
3. VESSEL TANK PRESSURES TANK NAME 1 PRESSURE 1106 AVERAGE TANK PRESSURE = 4. VESSEL TANK VOLUMES TANK NAME 1 TANK VOLUME m3 0.000 THERMAL CORR. 1.000000 CORR. VOLUME m3 0.000
2 1107 1106.5
2 0.000 1.000000 0.000
3 1106 mbar
TRIM LIST
: 06:07
°C
4 1107 ATMOSPHERIC PRESSURE =
3 0.000 1.000000 0.000
= =
TIME
AVERAGE LIQUID TEMPERATURE =
992
mbar
4 0.000 1.000000 0.000
VESSEL VOLUME =
5. ADDITION INFORMATION AND COMMENTS FWD DRAFT = 9.00 m AFT DRAFT = 9.02 m
: 5-Jun-2007
0.02 m 0.02 °S
0.000
CUBIC METERS
VESSEL DECK LINES
=
EMPTY
ABDELOUAHEB ZENNIR FOR INTERTEK Vessel Measurement 2
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
VESSEL MEASUREMENT - REFERENCE ONLY VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN 1. VESSEL TANK MEASUREMENTS TANK NAME 1 SYSTEM TYPE PRIMARY 1ST READING m 0.000 2ND READING m 0.000 3RD READING m 0.000 4TH READING m 0.000 5TH READING m 0.000 AVG. GAUGE m 0.000 DENSITY CORR. m 0.000 TEMP. CORR. m 0.000 TRIM CORR. m 0.000 LIST CORR. m 0.000 CORR. GAUGE m 0.000
DATE
2 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
3 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
4 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
2 30.08 V 29.78 V 29.25 V 29.26 V 29.12 V
3 29.44 V 29.18 V 28.80 V 28.67 V 28.65 V
4 29.70 V 29.61 V 29.48 V 29.48 V 29.33 V
TANK AVERAGE °C 29.26 V 29.50 V 28.95 V TANK AVERAGE °C AVERAGE VAPOR TEMPERATURE = 29.3 °C
29.52 V
2. VESSEL TANK TEMPERATURES TANK NAME 1 TEMP PROBE #1 °C 29.76 V TEMP PROBE #2 °C 29.46 V TEMP PROBE #3 °C 29.08 V TEMP PROBE #4 °C 29.28 V TEMP PROBE #5 °C 28.71 V TEMP PROBE #6 °C
3. VESSEL TANK PRESSURES TANK NAME 1 PRESSURE 1106 AVERAGE TANK PRESSURE = 4. VESSEL TANK VOLUMES TANK NAME 1 TANK VOLUME m3 0.000 THERMAL CORR. 1.000000 CORR. VOLUME m3 0.000
2 1107 1106.5
2 0.000 1.000000 0.000
3 1106 mbar
TRIM LIST
: 06:07
°C
4 1107 ATMOSPHERIC PRESSURE =
3 0.000 1.000000 0.000
= =
TIME
AVERAGE LIQUID TEMPERATURE =
992
mbar
4 0.000 1.000000 0.000
VESSEL VOLUME =
5. ADDITION INFORMATION AND COMMENTS FWD DRAFT = 9.00 m AFT DRAFT = 9.02 m
: 5-Jun-2007
0.02 m 0.02 °S
0.000
CUBIC METERS
VESSEL DECK LINES
=
EMPTY
ABDELOUAHEB ZENNIR FOR INTERTEK Vessel Measurement 3
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
VESSEL MEASUREMENT - REFERENCE ONLY VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN 1. VESSEL TANK MEASUREMENTS TANK NAME 1 SYSTEM TYPE PRIMARY 1ST READING m 0.000 2ND READING m 0.000 3RD READING m 0.000 4TH READING m 0.000 5TH READING m 0.000 AVG. GAUGE m 0.000 DENSITY CORR. m 0.000 TEMP. CORR. m 0.000 TRIM CORR. m 0.000 LIST CORR. m 0.000 CORR. GAUGE m 0.000
DATE
2 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
3 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
4 PRIMARY 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
2 30.08 V 29.78 V 29.25 V 29.26 V 29.12 V
3 29.44 V 29.18 V 28.80 V 28.67 V 28.65 V
4 29.70 V 29.61 V 29.48 V 29.48 V 29.33 V
TANK AVERAGE °C 29.26 V 29.50 V 28.95 V TANK AVERAGE °C AVERAGE VAPOR TEMPERATURE = 29.3 °C
29.52 V
2. VESSEL TANK TEMPERATURES TANK NAME 1 TEMP PROBE #1 °C 29.76 V TEMP PROBE #2 °C 29.46 V TEMP PROBE #3 °C 29.08 V TEMP PROBE #4 °C 29.28 V TEMP PROBE #5 °C 28.71 V TEMP PROBE #6 °C
3. VESSEL TANK PRESSURES TANK NAME 1 PRESSURE 1106 AVERAGE TANK PRESSURE = 4. VESSEL TANK VOLUMES TANK NAME 1 TANK VOLUME m3 0.000 THERMAL CORR. 1.000000 CORR. VOLUME m3 0.000
2 1107 1106.5
2 0.000 1.000000 0.000
3 1106 mbar
TRIM LIST
: 06:07
°C
4 1107 ATMOSPHERIC PRESSURE =
3 0.000 1.000000 0.000
= =
TIME
AVERAGE LIQUID TEMPERATURE =
992
mbar
4 0.000 1.000000 0.000
VESSEL VOLUME =
5. ADDITION INFORMATION AND COMMENTS FWD DRAFT = 9.00 m AFT DRAFT = 9.02 m
: 5-Jun-2007
0.02 m 0.02 °S
0.000
CUBIC METERS
VESSEL DECK LINES
=
EMPTY
ABDELOUAHEB ZENNIR FOR INTERTEK Vessel Measurement 4
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
GENERAL INFORMATION VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
1. VESSEL - CUSTODY TRANSFER MEASUREMENT SYSTEMS VESSEL TANK DESIGN TYPE : MEMBRANE PRIMARY GAUGING DEVICE MAKE : FOXBORO SECONDARY GAUGING DEVICE MAKE : WHESSOE TEMPERATURE DEVICE MAKE : FOXBORO PRESSURE DEVICE MAKE : FOXBORO
:
4-Aug-2009
TO
5-Aug-2009
NUMBER OF TANKS : 4 TYPE : RADAR TYPE : FLOAT NUMBER PER TANK : 6 RANGE : 800 MBAR TO 1400 MBAR
2. VESSEL - CARGO TANK CAPACITY & TEMPERATURE PROBE HEIGHT PROFILES TANK NAME 1 2 3 4 GAUGE HEIGHT m 41.491 41.509 41.511 41.498 TANK CAPACITY m3 37,326.000 37,336.000 37,352.000 37,345.000 TEMP PROBE #1 26.586 26.471 26.495 26.496 TEMP PROBE #2 25.525 25.604 25.520 25.517 TEMP PROBE #3 22.847 22.839 22.849 22.844 TEMP PROBE #4 13.480 13.432 13.482 13.475 TEMP PROBE #5 6.791 6.776 6.794 6.789 TEMP PROBE #6 0.025 0.025 0.026 0.025
3. VESSEL - CARGO QUANTITY CONSUMED AS FUEL BY VESSEL METER I.D. O.C.T. READING C.C.T. READING OBSERVED CONDITIONS 1. ENGINE ROOM OP : 0 kg CL : 0 kg MASS BASED CALCS 2. 3. 4. 5. 6. 7. THE ENERGY OF GAS CONSUMED AS FUEL IS BASED ON : THE HIGHER HEATING VALUE OF LNG CARGO 4. TERMINAL - GAS CHROMATOGRAPHY EQUIPMENT TESTING EQUIPMENT MAKE : AC.AGILENT CERTIFIED REFERENCE GAS SUPPLIER : SCOTT GAS GC VERIFICATION BEFORE : YES
MODEL SERIAL # AFTER
5. TERMINAL - PRIMARY SAMPLING SYSTEM SAMPLE COLLECTOR : GAS SAMPLE HOLDER SAMPLING SYSTEM TYPE # OF SAMPLES PER SET : 3 SIZE OF SAMPLE FREQUENCY OF SAMPLING : SAMPLED AFTER COMPLETION OF BULK LOADING
APPLY YES
: 6890 : 7800102 : NO
: CONTINUOUS : 2250 cc
6. TERMINAL - SHORE STORAGE & CAPACITY TANKS 1 2 TANK ID # T 3101 T 3102 CAPACITY (M3) 135,000 135,000 7. ADDITION INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
OPERATIONAL CHECKLIST VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. SHORE OPERATIONS - PRIOR TO LOAD DID THE TERMINAL SUPPLY A CURRENT REPORT OF CALIBRATION FOR THE GC ? WAS THE GC VERIFIED AGAINST A CERTIFIED REFERENCE GAS PRIOR TO LOADING / USAGE ? DOES THE CERTIFIED REFERENCE GAS HAVE A CURRENT CERTIFICATE OF CALIBRATION ?
YES YES YES
2. VESSEL OPERATIONS - ON ARRIVAL ARE ALL PRIMARY CUSTODY GAUGING DEVISES OPERATIONAL ON ARRIVAL ? DOES THE PRIMARY SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? ARE ALL SECONDARY CUSTODY GAUGING DEVISES OPERATIONAL ON ARRIVAL ? DOES THE SECONDARY SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? ARE ALL CUSTODY REMOTE TEMPERATURE DEVISES OPERATIONAL ON ARRIVAL ? DOES THE TEMPERATURE SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? ARE ALL CUSTODY PRESSURE DEVISES OPERATIONAL ON ARRIVAL ? DOES THE PRESSURE SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? WERE THE TANKS "BOTTLED UP" DURING OPENING CUSTODY TRANSFER MEASUREMENT ? DOES THE VESSEL HAVE CURRENT CERTIFIED TANK STRAPPING TABLES ? ARE THE TANK STRAPPING TABLES WRITTEN IN ENGLISH ? DOES THE TANK STRAPPING TABLES EXPLAIN HOW TO UTILIZED THE TABLES ? DOES THE TANK STRAPPING TABLES HAVE GAUGE CORRECTION FACTORS (TRIM, LIST, ETC) ? DOES THE TANK STRAPPING TABLES HAVE 100% CAPACITIES FOR INDIVIDUAL TANKS ? DOES THE TANK STRAPPING TABLES HAVE GAUGE HEIGHTS FOR INDIVIDUAL TANKS ? DOES THE TANK STRAPPING TABLES HAVE TEMPERATURE PROFILES FOR INDIVIDUAL TANKS ?
YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES
3. SHORE OPERATIONS - DURING LOAD WAS CORRECT NUMBER OF SAMPLES PULLED AT THE PROPER TIME DURING LOAD ?
YES
4. VESSEL OPERATIONS - ON DEPARTURE ARE ALL PRIMARY CUSTODY GAUGING DEVISES OPERATIONAL ON DEPARTURE ? ARE ALL SECONDARY CUSTODY GAUGING DEVISES OPERATIONAL ON DEPARTURE ? ARE ALL CUSTODY REMOTE TEMPERATURE DEVISES OPERATIONAL ON DEPARTURE ? ARE ALL CUSTODY PRESSURE DEVISES OPERATIONAL ON DEPARTURE ? WERE THE TANKS "BOTTLED UP" DURING CLOSING CUSTODY TRANSFER MEASUREMENT ?
YES YES YES YES YES
5. SHORE OPERATIONS - AFTER LOAD WAS THE GC VERIFIED AGAINST A CERTIFIED REFERENCE AFTER LOADING / USAGE ? DID THE TERMINAL SUPPLY A CERTIFICATE OF VERIFICATION FOR THE GC ? DID THE TERMINAL SUPPLY A COMPOSITIONAL PRINT OUT OF THE GC DURING LOAD ?
YES YES YES
6. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT Checklist 1 - Discontinuous Sampling System
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
OPERATIONAL CHECKLIST VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. SHORE OPERATIONS - PRIOR TO LOAD WAS THE GAS SAMPLING EQUIPMENT (LINES, TANK, ETC.) INSPECTED AND PURGED ? WAS THE GAS SAMPLING EQUIPMENT SET UP PROPERLY TO RECEIVE SAMPLE ?
YES YES
2. VESSEL OPERATIONS - ON ARRIVAL WERE ALL PRIMARY CUSTODY GAUGING DEVISES OPERATIONAL ON ARRIVAL ? DID THE PRIMARY SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? WERE ALL SECONDARY CUSTODY GAUGING DEVISES OPERATIONAL ON ARRIVAL ? DID THE SECONDARY SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? WERE ALL CUSTODY REMOTE TEMPERATURE DEVISES OPERATIONAL ON ARRIVAL ? DID THE TEMPERATURE SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? WERE ALL CUSTODY PRESSURE DEVISES OPERATIONAL ON ARRIVAL ? DID THE PRESSURE SYSTEM HAVE A CURRENT CERTIFICATE OF CALIBRATION ? WERE THE TANKS "BOTTLED UP" DURING OPENING CUSTODY TRANSFER MEASUREMENT ? DID THE VESSEL HAVE CURRENT CERTIFIED TANK STRAPPING TABLES ? WERE THE TANK STRAPPING TABLES WRITTEN IN ENGLISH ? DID THE TANK STRAPPING TABLES EXPLAIN HOW TO UTILIZED THE TABLES ? DID THE TANK STRAPPING TABLES HAVE GAUGE CORRECTION FACTORS (TRIM, LIST, ETC) ? DID THE TANK STRAPPING TABLES HAVE 100% CAPACITIES FOR INDIVIDUAL TANKS ? DID THE TANK STRAPPING TABLES HAVE GAUGE HEIGHTS FOR INDIVIDUAL TANKS ? DID THE TANK STRAPPING TABLES HAVE TEMPERATURE PROFILES FOR INDIVIDUAL TANKS ?
YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES YES
3. SHORE OPERATIONS - DURING LOAD WERE THE CORRECT NUMBER OF SPOT SAMPLES PULLED AT THE PROPER TIME DURING LOAD ?
YES
4. VESSEL OPERATIONS - ON DEPARTURE WERE ALL PRIMARY CUSTODY GAUGING DEVISES OPERATIONAL ON DEPARTURE ? WERE ALL SECONDARY CUSTODY GAUGING DEVISES OPERATIONAL ON DEPARTURE ? WERE ALL CUSTODY REMOTE TEMPERATURE DEVISES OPERATIONAL ON DEPARTURE ? WERE ALL CUSTODY PRESSURE DEVISES OPERATIONAL ON DEPARTURE ? WERE THE TANKS "BOTTLED UP" DURING CLOSING CUSTODY TRANSFER MEASUREMENT ?
YES YES YES YES YES
5. SHORE OPERATIONS - AFTER LOAD DID THE GAS SAMPLING EQUIPMENT WORK PROPERLY THROUGHOUT THE ENTIRE LOAD ? WERE THE CORRECT NUMBER OF TESTING SAMPLES COLLECTED FROM THE GAS SAMPLE HOLDER ? DID THE TERMINAL SUPPLY A CURRENT REPORT OF CALIBRATION FOR THE GC ? WAS THE GC VERIFIED AGAINST A CERTIFIED REFERENCE GAS PRIOR TO TESTING ? WAS THE GC VERIFIED AGAINST A CERTIFIED REFERENCE GAS AFTER TESTING ? DID THE CERTIFIED REFERENCE GAS HAVE A CURRENT CERTIFICATE OF ANALYSIS ? DID THE TERMINAL SUPPLY A CERTIFICATE OF VERIFICATION FOR THE GC AFTER TESTING ? DID THE TERMINAL SUPPLY A COMPOSITIONAL PRINT OUT OF THE GC ANALYSIS ?
YES YES YES YES YES YES YES YES
6. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT Checklist 2 - Continuous Sampling System
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
VERIFICATION OF GC VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
4-Aug-2009
TO
5-Aug-2009
1. OPENING VERIFICATION OF GC CERTIFIED VARIANCE TEST GC VARIANCE TEST GC VARIANCE TEST GC VARIANCE COMPONENT RESULTS ALLOWED RUN #1 PCT. RUN #2 PCT. RUN #3 PCT. METHANE 91.9398 1.00% 91.9301 0.01% 91.9397 0.00% 91.9355 0.00% ETHANE 5.0400 10.00% 5.0499 -0.20% 5.0412 -0.02% 5.0422 -0.04% PROPANE 1.0020 10.00% 1.0028 -0.08% 1.0034 -0.14% 1.0020 0.00% ISO BUTANE 0.1520 10.00% 0.1526 -0.39% 0.1523 -0.20% 0.1530 -0.66% N-BUTANE 0.2030 10.00% 0.2031 -0.05% 0.2027 0.15% 0.2030 0.00% ISO PENTANE 0.0531 10.00% 0.0532 -0.19% 0.0528 0.56% 0.0535 -0.75% N-PENTANE 0.0538 10.00% 0.0543 -0.93% 0.0534 0.74% 0.0540 -0.37% HEXANE + HVR 0.0503 10.00% 0.0501 0.40% 0.0500 0.60% 0.0508 -0.99% NITROGEN 1.0130 10.00% 1.0130 0.00% 1.0139 -0.09% 1.0150 -0.20% CARBON DIOXIDE 0.4930 10.00% 0.4909 0.43% 0.4906 0.49% 0.4910 0.41% OXYGEN 0.0000 10.00% 0.0000 0.00% 0.0000 0.00% 0.0000 0.00% TOTAL 100.0000 100.0000 100.0000 100.0000 OPENING VERIFICATION FOUND WITHIN VARIANCE YES DATE : 26-May-2007 TIME : 08:00 2. CLOSING VERIFICATION OF GC CERTIFIED VARIANCE TEST GC VARIANCE TEST GC VARIANCE TEST GC VARIANCE COMPONENT RESULTS ALLOWED RUN #1 PCT. RUN #2 PCT. RUN #3 PCT. METHANE 91.9398 1.00% 91.9301 0.01% 91.9397 0.00% 91.9355 0.00% ETHANE 5.0400 10.00% 5.0499 -0.20% 5.0412 -0.02% 5.0422 -0.04% PROPANE 1.0020 10.00% 1.0028 -0.08% 1.0034 -0.14% 1.0020 0.00% ISO BUTANE 0.1520 10.00% 0.1526 -0.39% 0.1523 -0.20% 0.1530 -0.66% N-BUTANE 0.2030 10.00% 0.2031 -0.05% 0.2027 0.15% 0.2030 0.00% ISO PENTANE 0.0531 10.00% 0.0532 -0.19% 0.0528 0.56% 0.0535 -0.75% N-PENTANE 0.0538 10.00% 0.0543 -0.93% 0.0534 0.74% 0.0540 -0.37% HEXANE + HVR 0.0503 10.00% 0.0501 0.40% 0.0500 0.60% 0.0508 -0.99% NITROGEN 1.0130 10.00% 1.0130 0.00% 1.0139 -0.09% 1.0150 -0.20% CARBON DIOXIDE 0.4930 10.00% 0.4909 0.43% 0.4906 0.49% 0.4910 0.41% OXYGEN 0.0000 10.00% 0.0000 0.00% 0.0000 0.00% 0.0000 0.00% TOTAL 100.0000 100.0000 100.0000 100.0000 CLOSING VERIFICATION FOUND WITHIN VARIANCE YES DATE : 26-May-2007 TIME : 10:00 3. EQUIPMENT INFORMATION AND CERTIFIED REFERENCE GAS TESTING EQUIPMENT MAKE : AC.AGILENT LAST CALIBRATION DATE : 15-Feb-2007 CERTIFIED REFERENCE GAS SUPPLIER : SCOTT GAS CERTIFICATION DATE : 15-Feb-2007
MODEL TIME SERIAL # TIME
: : : :
6890 17:00 7800102 17:00
4. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT Verification of GC 1 - Site Specific
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
VERIFICATION OF GC VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN INSTRUMENT : GC C (HP 5890)
DATE
LABORATORY TEMP :
1. REFERENCE STANDARD GAS COMPONENT METHANE CH4 ETHANE C2H6 PROPANE C3H8 ISO BUTANE i-C4H10 N-BUTANE n-C4H10 ISO PENTANE i-C5H12 N-PENTANE n-C5H12 NITROGEN N2 OXYGEN O2 CARBON DIOXIDE CO2 TOTAL 2. SAMPLE GAS COMPONENT
90.4013 4.4400 3.3500 0.7080 0.6850 0.0286 0.0286 0.2870 0.0297 0.0418 100.0000
First Sample Count Peak Area (C)
METHANE CH4 ETHANE C2H6 PROPANE C3H8 ISO BUTANE i-C4H10 N-BUTANE n-C4H10 ISO PENTANE i-C5H12 N-PENTANE n-C5H12 NITROGEN N2 OXYGEN O2 CARBON DIOXIDE CO2 TOTAL 3. NORMALIZATION COMPONENT
Cylinder # :
Concent Mol % (A)
276,238 692,500 440,672 89,076 72,378 0 0 2,494 0 0
Average Sample Count Peak Area (E)
METHANE CH4 ETHANE C2H6 PROPANE C3H8 ISO BUTANE i-C4H10 N-BUTANE n-C4H10 ISO PENTANE i-C5H12 N-PENTANE n-C5H12 NITROGEN N2 OXYGEN O2 CARBON DIOXIDE CO2 TOTAL
276,275.5 692,603.0 440,803.5 89,093.0 72,333.0 0.0 0.0 2,491.0 0.0 0.0
: 13-Nov-2007
First RSG Count Peak Area
272,177 606,946 702,057 198,637 193,331 10,178 9,918 32,198 3,195 5,791
Cylinder # : CPC-01 Second Sample Unnormal Count Mol % Peak Area (C) x (A) / (B) (D) 91.662 5.062 2.103 0.317 0.256 0.000 0.000 0.022 0.000 0.000 99.422
Unnormal Mol % (E) x (A) / (B)
276,313 692,706 440,935 89,110 72,288 0 0 2,488 0 0
Reported Value Mol%
91.674 5.063 2.104 0.317 0.256 0.000 0.000 0.022 0.000 0.000 99.436
92.19 5.09 2.12 0.32 0.26 0.00 0.00 0.02 0.00 0.00 100.00
: 15:00
23-23.5 °C
GS 66889
Second RSG Count Peak Area
272,701 607,832 701,594 198,953 193,667 10,224 9,937 32,521 3,283 5,636
TIME
Repeatability
Average RSG Count Peak Area (B)
0.19 0.15 0.07 0.16 0.17 0.45 0.19 1.00 2.72 2.71
272,439.0 607,389.0 701,825.5 198,795.0 193,499.0 10,201.0 9,927.5 32,359.5 3,239.0 5,713.5
Seal # :
004659
Unnormal Mol % (D) x (A) / (B)
Repeatability
91.687 5.064 2.105 0.317 0.256 0.000 0.000 0.022 0.000 0.000 99.451
Load Port Mol %
0.03 0.03 0.06 0.04 0.12 0.00 0.00 0.24 0.00 0.00
Difference %
92.8085 4.7397 1.8893 0.2689 0.2151 0.0022 0.0000 0.0762 0.0000 0.0000 100.000
-0.6185 0.3503 0.2307 0.0511 0.0449 -0.0022 -0.0562
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT Verification of GC 2 - Site Specific
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
BUNKER SURVEY VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN 1. VESSEL HISTORY FROM CHIEF ENGINEER BUNKER PRODUCT : FUEL OIL LAST PORT OF CALL : SINGAPORE BUNKERS ON DEPARTURE : 1337.000 BUNKERS AT E.O.S.P. : 1463.160 BUNKERS RECEIVED INTRANSIT : 3713.910 BUNKERS RECEIVED IN PORT : 0.000 2. INSPECTION UPON ARRIVAL VESSEL'S ULLAGES TANK METERS TANK 1 FWD 24.200 TANK 2 STB 4.970 TANK 2 PORT 8.401 TANK 4 STB 3.633 TANK 1 SETTLING 8.790 TANK 2 SETTLING 5.476
TOTALS DATE : 3-Jun-2008
G.O.V. m3 0.000 481.000 474.000 141.000 212.000 197.000
G.O.V. m3 0.000 482.000 474.000 140.000 213.000 123.000
G.O.V. = 1432.000 TIME : 15:00
4. ADDITIONAL INFORMATION AND COMMENTS QUANTITY OF BUNKERS CONSUMED DURING VOYAGE QUANTITY OF BUNKERS CONSUMED DURING LOAD
TEMP. °C 20.0 42.8 49.0 39.7 60.0 60.0
V.C.F. T54B - 2004 0.99658 0.98092 0.97664 0.98306 0.96902 0.96902
DRAFT FWD
TEMP. °C 20.0 43.0 44.0 39.0 55.0 55.0
:
4-Aug-2009
TO
:
G.S.V. m3 0.000 471.823 462.927 138.611 205.432 190.897
DENSITY @ 15°C 0.9894 0.9894 0.9894 0.9894 0.9894 0.9894
G.S.V. = 1469.691 M.T. = 9.60 m DRAFT AFT :
V.C.F. T54B - 2004 0.99658 0.98078 0.98009 0.98354 0.97249 0.97249
DRAFT FWD
: :
:
5-Aug-2009
DAYS AT SEA : 9.00 AT ANCH : 0.00 AVERAGE BUNKER CONSUMPTION PER DAY AT SEA : 200.000 METRIC TONS AT LOAD : 20.000 METRIC TONS AT DISC : 20.000 METRIC TONS AT ANCHOR : 20.000 METRIC TONS
METRIC TONS METRIC TONS METRIC TONS METRIC TONS
G.O.V. = 1505.000 TIME : 07:40
3. INSPECTION PRIOR TO SAILING VESSEL'S ULLAGES TANK METERS TANK 1 FWD 0.000 TANK 2 STB 4.950 TANK 2 PORT 8.420 TANK 4 STB 3.630 TANK 1 SETTLING 8.790 TANK 2 SETTLING 5.130
TOTALS DATE : 5-Jun-2008
DATE
G.S.V. m3 0.000 472.736 464.563 137.696 207.140 119.616
DENSITY @ 15°C 0.9894 0.9894 0.9894 0.9894 0.9894 0.9894
G.S.V. = 1401.751 M.T. = 11.45 m DRAFT AFT :
M. TONS ( AIR ) 0.000 466.302 457.511 136.990 203.029 188.663
1452.495 9.78 m
M. TONS ( AIR ) 0.000 467.205 459.127 136.085 204.717 118.217
1385.351 11.50 m
3598.415 METRIC TONS 67.144 METRIC TONS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT Bunker - Fuel Oil
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
BUNKER SURVEY VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN 1. VESSEL HISTORY FROM CHIEF ENGINEER BUNKER PRODUCT : MARINE DIESEL OIL LAST PORT OF CALL : SINGAPORE BUNKERS ON DEPARTURE : 159.890 BUNKERS AT E.O.S.P. : 133.800 BUNKERS RECEIVED INTRANSIT : 0.000 BUNKERS RECEIVED IN PORT : 0.000 2. INSPECTION UPON ARRIVAL VESSEL'S ULLAGES TANK METERS D.O TK 6.062 D.O SERVICE 3.908
TOTALS DATE : 3-Jun-2008
G.O.V. m3 80.200 77.300
G.O.V. m3 80.200 77.300
G.O.V. = 157.500 TIME : 15:00
4. ADDITIONAL INFORMATION AND COMMENTS QUANTITY OF BUNKERS CONSUMED DURING VOYAGE QUANTITY OF BUNKERS CONSUMED DURING LOAD
TEMP. °C 25.0 25.0
V.C.F. T54B - 2004 0.99180 0.99180
DRAFT FWD
TEMP. °C 25.0 25.0
:
4-Aug-2009
TO
:
G.S.V. m3 79.542 76.666
DENSITY @ 15°C 0.8600 0.8600
G.S.V. = 156.209 M.T. = 9.60 m DRAFT AFT :
V.C.F. T54B - 2004 0.99180 0.99180
DRAFT FWD
: :
:
5-Aug-2009
DAYS AT SEA : 9.00 AT ANCH : 0.00 AVERAGE BUNKER CONSUMPTION PER DAY AT SEA : 0.000 METRIC TONS AT LOAD : 0.000 METRIC TONS AT DISC : 1.000 METRIC TONS AT ANCHOR : 0.000 METRIC TONS
METRIC TONS METRIC TONS METRIC TONS METRIC TONS
G.O.V. = 157.500 TIME : 07:40
3. INSPECTION PRIOR TO SAILING VESSEL'S ULLAGES TANK METERS D.O TK 6.063 D.O SERVICE 3.908
TOTALS DATE : 5-Jun-2008
DATE
G.S.V. m3 79.542 76.666
DENSITY @ 15°C 0.8600 0.8600
G.S.V. = 156.209 M.T. = 11.45 m DRAFT AFT :
M. TONS ( AIR ) 68.319 65.849
134.168 9.78 m
M. TONS ( AIR ) 68.319 65.849
134.168 11.50 m
25.722 METRIC TONS 0.000 METRIC TONS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT Bunker - Diesel Oil
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
TIME LOG VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN 1. TIMES DATE 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 4-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009 5-Aug-2009
HOUR 05:15 09:15 06:54 08:15 09:15 09:22 09:22 09:32 09:49 10:00 10:30 10:33 09:15 10:27 10:28 10:40 12:15 12:20 12:59 02:47 03:25 04:21 04:22 04:25 04:39 05:00 05:15 06:30 06:05 06:25 06:26 06:52 07:17 07:30 07:40 08:00 08:00
DATE
:
4-Aug-2009
TO
5-Aug-2009
EVENT END OF SEA PASSAGE NOTICE OF READINESS TENDERED PILOT ON BOARD FIRST LINE ASHORE VESSEL ALL FAST TERMINAL GANGWAY DOWN & SECURE INSPECTOR ON BOARD COMMENCED CONNECTION OF CARGO & VAPOR ARMS COMPLETED CONNECTION OF CARGO & VAPOR ARMS COMMENCED PRE-LOAD KEY / SAFETY MEETING COMPLETED PRE-LOAD KEY / SAFETY MEETING COMMENCED TESTING OF E.S.D. NOTICE OF READINESS ACCEPTED COMMENCED OPENING CUSTODY TRANSFER INSPECTION COMPLETED OPENING CUSTODY TRANSFER INSPECTION COMMENCED COOL DOWN OF CARGO ARMS & VESSEL LINES COMPLETED COOL DOWN OF CARGO ARMS & VESSEL LINES COMMENCED LOADING OF CARGO FULL RATE LOADING LOADING RATE DOWN START COMPLETED LOADING COMMENCED CLOSING CUSTODY TRANSFER INSPECTION COMPLETED CLOSING CUSTODY TRANSFER INSPECTION COMMENCED DISCONNECTION OF VARGO & VAPOR ARMS COMPLETED DISCONNECTION OF CARGO & VAPOR ARMS POST LOADING MEETING & DOCUMENTATION VESSEL CLEAR ETS ANALYSIS COMPLETED COMMENCED CLOSING CUSTODY TRANSFER INSPECTION COMPLETED CLOSING CUSTODY TRANSFER INSPECTION COMMENCED DISCONNECTION OF CARGO & VAPOR ARMS COMPLETED DISCONNECTION OF CARGO & VAPOR ARMS POST LOADING MEETING & DOCUMENTATION VESSEL CLEARED VESSEL SAILED ANALYSIS COMPLETED
2. ADDITIONAL INFORMATION AND COMMENTS Sampling started : 17:15 0n 31st July 2008 and completed at 06:20 0n 01st August 2008 Analysis completed : 09:15 on 1st August 2008
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT Time Log - Page 1
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
TIME LOG VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN 1. TIMES DATE
HOUR
DATE
:
4-Aug-2009
TO
5-Aug-2009
EVENT
2. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT Time Log - Page 2
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
TIME LOG VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN 1. TIMES DATE
HOUR
DATE
:
4-Aug-2009
TO
5-Aug-2009
EVENT
2. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT Time Log - Page 3
FOR TERMINAL
FOR VESSEL LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
LETTER OF PROTEST VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
TIME
:
TO :
SIR : ON BEHALF OF OUR CLIENT(S), WE HAVE BEEN APPOINTED INSPECTORS ON THE ABOVE NAMED VESSEL. ACTING FOR AND ON THEIR BEHALF, WE HEREBY NOTIFY YOU THAT ON THE LISTED DATE AND TIME THE FOLLOWING OCCURRED.
WE HEREBY RESERVE THE RIGHT OF OUR PRINCIPALS TO REFER TO THIS MATTER AT A LATER DATE AND TAKE SUCH ACTION AS MAY BE DEEMED NECESSARY. KINDLY ACKNOWLEDGE RECEIPT ON THE COPY THEREOF AND RETURN IT TO US. THE SIGNATURE THUS OBTAINED ARE FOR RECEIPT ONLY AND IN NO WAY ACKNOWLEDGE RESPONSIBILITY FOR THE INCIDENT. RECEIVED BY
YOURS FAITHFULLY,
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT LOP 1
LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
LETTER OF PROTEST VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
TIME
:
TO :
SIR : ON BEHALF OF OUR CLIENT(S), WE HAVE BEEN APPOINTED INSPECTORS ON THE ABOVE NAMED VESSEL. ACTING FOR AND ON THEIR BEHALF, WE HEREBY NOTIFY YOU THAT ON THE LISTED DATE AND TIME THE FOLLOWING OCCURRED.
WE HEREBY RESERVE THE RIGHT OF OUR PRINCIPALS TO REFER TO THIS MATTER AT A LATER DATE AND TAKE SUCH ACTION AS MAY BE DEEMED NECESSARY. KINDLY ACKNOWLEDGE RECEIPT ON THE COPY THEREOF AND RETURN IT TO US. THE SIGNATURE THUS OBTAINED ARE FOR RECEIPT ONLY AND IN NO WAY ACKNOWLEDGE RESPONSIBILITY FOR THE INCIDENT. RECEIVED BY
YOURS FAITHFULLY,
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT LOP2
LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
LETTER OF PROTEST VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
TIME
:
TO :
SIR : ON BEHALF OF OUR CLIENT(S), WE HAVE BEEN APPOINTED INSPECTORS ON THE ABOVE NAMED VESSEL. ACTING FOR AND ON THEIR BEHALF, WE HEREBY NOTIFY YOU THAT ON THE LISTED DATE AND TIME THE FOLLOWING OCCURRED.
WE HEREBY RESERVE THE RIGHT OF OUR PRINCIPALS TO REFER TO THIS MATTER AT A LATER DATE AND TAKE SUCH ACTION AS MAY BE DEEMED NECESSARY. KINDLY ACKNOWLEDGE RECEIPT ON THE COPY THEREOF AND RETURN IT TO US. THE SIGNATURE THUS OBTAINED ARE FOR RECEIPT ONLY AND IN NO WAY ACKNOWLEDGE RESPONSIBILITY FOR THE INCIDENT. RECEIVED BY
YOURS FAITHFULLY,
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT LOP 3
LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
LETTER OF PROTEST VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
:
TIME
:
TO :
SIR : ON BEHALF OF OUR CLIENT(S), WE HAVE BEEN APPOINTED INSPECTORS ON THE ABOVE NAMED VESSEL. ACTING FOR AND ON THEIR BEHALF, WE HEREBY NOTIFY YOU THAT ON THE LISTED DATE AND TIME THE FOLLOWING OCCURRED.
WE HEREBY RESERVE THE RIGHT OF OUR PRINCIPALS TO REFER TO THIS MATTER AT A LATER DATE AND TAKE SUCH ACTION AS MAY BE DEEMED NECESSARY. KINDLY ACKNOWLEDGE RECEIPT ON THE COPY THEREOF AND RETURN IT TO US. THE SIGNATURE THUS OBTAINED ARE FOR RECEIPT ONLY AND IN NO WAY ACKNOWLEDGE RESPONSIBILITY FOR THE INCIDENT. RECEIVED BY
YOURS FAITHFULLY,
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT LOP 4
LNG-LD-009H1 (07-AUG-09) - 14
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
NIGERIA LNG CERTIFICATE OF LOADING VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
1. IDENTIFICATION (a) CARGO RECEIVER (NLNG CUSTOMER) (b) NIGERIA LNG CARGO NUMBER (c) COMMENCED LOADING OF LNG (d) COMPLETED LOADING ON LNG 2. BASIC DATA (a) (b) (c) (d) (e)
(f)
(g) 3. RESULTS (a) (b) (c) (d)
DATE DATE
: 15-Apr-2008
: : : :
BRITISH GAS 963 11-May-2008 13-May-2008
LIQUID LNG VOLUME LOADED : AVERAGE TEMPERATURE OF LIQUID AFTER LOADING : AVERAGE TEMPERATURE OF VAPOR BEFORE LOADING : AVERAGE ABSOLUTE PRESSURE BEFORE LOADING : LNG CARGO COMPOSITION: COMPONENTS MOLE PERCENTAGE N2 NITROGEN 0.28 C1 METHANE 90.24 C2 ETHANE 5.95 C3 PROPANE 2.24 i-C4 ISO BUTANE 0.69 n-C4 N-BUTANE 0.58 i-C5 ISO PENTANE 0.02 n-C5 + N-PENTANE & HEAVIER 0 IMPURITIES CARBON DIOXIDE : MERCURY : MERCAPTAN : HYDROGEN SULFIDE : CARBONYL SULFIDE : TOTAL SULFUR : HYDROCARBON DEWPOINT (MAX - between 1-80 bar gauge) :
LNG DENSITY AT -160.2 °C GROSS CALORIFIC VALUE (MASS) GROSS CALORIFIC VALUE (VOLUME) WOBBE INDEX (VOLUME)
: : : :
TIME TIME
: 23:00 : 01:00
135,888.000 CUBIC METERS -160.2 °C -128.5 °C 1166 mbar
0 N/A N/A N/A N/A N/A N/A
mol % ng / Nm3 mg / Nm3 mg / Nm3 mg / Nm3 mg / Nm3 °C
459.080 kg / m3 54.44 MJ / kg 1115 BTU / SCF 1411 BTU / SCF
4. TOTAL QUANTITY OF LNG UNLOADED GROSS QUANTITY DELIVERED QUANTITY DISPLACED QUANTITY CONSUMED BY VESSEL QUANTITY FOR GAS-UP QUANTITY FOR COOL DOWN ADJUSTED QUANTITY DELIVERED
MEGAJOULES 3,395,719,322 11,743,022 0 0 0 3,383,978,343
MMBTU 3,218,508 11,130 0 0 0 3,207,380
KILOWATT HOURS 943,255,367 3,261,951 0 0 0 939,993,417
5. ADDITIONAL INFORMATION AND COMMENTS THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT CSR 1 - Nigeria LNG Certificate of Loading
LNG-LD-009H1 (07-AUG-09) - 14
BG DATA SHEET - LOAD
Vessel Name: Cargo No: Dates: File #:
SK SPLENDOR OF039/09-SL100-KG JAN 4-5, 2009 SUR/09/134
Terminal / Port: Last Port of Call: Dates at Last Port: Last Port CCT Volume:
135,888.000 3,207,380 3,207,380 62,172.077 0.000 0 0.000 0 404.978 136,292.944 135,888.000 -160.2 459.080 458.800 54.44 51593 1115 1117.6 1411 1414.3 3,218,508 11,130 3,207,380 0 3,207,378 1148.357 20-Jul-2009 4-Aug-2009
m3 MMBtu (60°F) MMBtu (60°F) MT m3 MMBtu (60°F) m3 MMBtu (60°F) m3 m3 m3 Deg. C KG/M3 KG/M3 MJ / kg (15°C) BTU / kg (60°F) BTU / SCF (60/60°F & 14.696 psi) BTU / SCF (60/60°F & 14.73 psi) BTU / SCF (60/60°F & 14.696 psi) BTU / SCF (60/60°F & 14.73 psi) MMBtu (60°F) MMBtu (60°F) MMBtu (60°F) MMBtu (60°F) MMBtu (60°F) m3 Date 15:48 Time Date 10:28 Time Hrs E to W Days % per day % per day
OMAN LNG INCHEON 20-Jul-2009 1,553.335
LNG Data Total Load Volume Total Load Quantity BG - Total Load Quantity Total Load Quantity Cooldown Volume Cooldown Volume Gas up Volume Gas up Volume Vessel OCT Volume before loading Vessel CCT Volume after loading Vessel Volume Received Observied Liquid Temp after loading LNG Density @ -160.2 °C LNG Density @ -160.0 °C Higher Heating Value (mass) BG - Higher Heating Value (mass) Higher Heating Value (Volume) BG - Higher Heating Value (Volume) Wobbe Index BG - Wobbe Index Gross Energy Received Vapor Return Energy Delivered Gas Consumed During Load Net Energy Received Intransit Difference Last Port of call CCT inspection: Load Port OCT inspection Time zone adjustment between ports Length of Voyage Estimated LNG Boil-off per day Vessel Design Limits
Bunker Data (Fuel Oil) Bunkers on Closing Last Port Bunker Survey Bunkers on Opening Load Port Bunker Survey Bunkers on Closing Load Port Bunker Survey Bunkers Received intransit Average Daily Consumption Rates: At Load At Discharge At Sea At Anchorage:
1,337.000 1452.495 3-Jun-2008 1385.351 5-Jun-2008 3713.910
MT Date MT Date MT Date MT
20.000 20.000 200.000 20.000
MT MT MT MT
90.2400 5.9500 2.2400 0.6900 0.5800 0.0200 0.0000 0.0000 0.2800 0.0000
% mol % mol % mol % mol % mol % mol % mol % mol % mol % mol
Time 07:40
Time
15:00
Time
10:28 04:17
Time Time
Quality Methane CH4 Ethane C2H6 Propane C3H8 i-Butane i-C4H10 n-Butane n-C4H10 i-Pentane i-C5H12 n-Pentane n-C5H12 n-Hexane n-C6H14 Nitrogen N2 Carbon Dioxide CO2
Impurities Mercury Mercaptans Mercaptans Hydrogen Sulphide Hydrogen Sulphide Total Sulphur Total Sulphur
ng/Nm3 mg/Nm3 ppm mg/Nm3 ppm mg/Nm3 ppm
Time log Summary Additions OCT Inspection Completed CCT Inspection Completed
4-Aug-2009 5-Aug-2009
Date Date
m3
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
BP CERTIFICATE OF LOADING VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN
DATE
: 15-Apr-2008
1. QUALITY COMPONENTS METHANE 90.24 Mol % NITROGEN ETHANE 5.95 Mol % CARBON DIOXIDE PROPANE 2.24 Mol % OXYGEN ISO BUTANE 0.69 Mol % MERCURY N-BUTANE 0.58 Mol % MERCAPTAN ISO PENTANE 0.02 Mol % HYDROGEN SULFIDE N-PENTANE 0 Mol % CARBONYL SULFIDE N-HEXANE 0 Mol % TOTAL SULFUR AVERAGE TEMPERATURE OF LIQUID AFTER LOADING AVERAGE TEMPERATURE OF VAPOR BEFORE LOADING AVERAGE ABSOLUTE PRESSURE BEFORE LOADING LNG DENSITY AT -160.2 °C GROSS CALORIFIC VALUE (MASS) GROSS CALORIFIC VALUE (VOLUME) WOBBE INDEX (VOLUME) THE STANDARD REFERENCE CONDITIONS IDENTIFIES TEMPERATURE OF 60°F.
IMPURITIES 0.28 Mol % 0 Mol % 0 Mol % N/A ng / Nm3 N/A mg / Nm3 N/A mg / Nm3 N/A mg / Nm3 N/A mg / Nm3 -160.2 °C -128.5 °C 1166 mbar 459.080 kg / m3 54.44 MJ / kg 1115 BTU / SCF 1411 BTU / SCF
2. QUANTITY VESSEL VOLUME ON ARRIVAL
( OPENING CUSTODY TRANSFER )
404.978 CUBIC METERS
VESSEL VOLUME ON DEPARTURE
( CLOSING CUSTODY TRANSFER )
136,292.944 CUBIC METERS
VESSEL VOLUME DELIVERED ADJUSTED MASS DELIVERED
( ROUNDED AS PER THE S.P.A. )
GROSS QUANTITY DELIVERED QUANTITY DISPLACED QUANTITY CONSUMED BY VESSEL QUANTITY FOR GAS-UP QUANTITY FOR COOL DOWN ADJUSTED QUANTITY DELIVERED
MEGAJOULES 3,395,719,322 11,743,022 0 0 0 3,383,978,343
135,888.000 CUBIC METERS 62,172.077 METRIC TONS MMBTU KILOWATT HOURS 3,218,508 943,255,367 11,130 3,261,951 0 0 0 0 0 0 3,207,380 939,993,417
3. STATEMENT OF FACTS DATE 13-Apr-2008 13-Apr-2008 14-Apr-2008
HOUR 11:30 11:30 02:36
EVENT END OF SEA PASSAGE NOTICE OF READINESS TENDERED PILOT ON BOARD
14-Apr-2008
06:42
VESSEL ALL FAST
14-Apr-2008
06:42
NOTICE OF READINESS ACCEPTED
14-Apr-2008
08:12
CARGO ARMS CONNECTED
14-Apr-2008
09:00
COMMENCED CARGO OPERATIONS
15-Apr-2008
00:18
COMPLETED CARGO OPERATIONS
15-Apr-2008 15-Apr-2008
00:48 02:54
CARGO ARMS DISCONNECTED VESSEL DEPARTURE
4. ADDITIONAL INFORMATION AND COMMENTS
Mohamed-Hamid BOUABDELLI FOR INTERTEK CALEB BRETT CSR 3 - BP Certificate of Loading
LNG-LD-009H1 (07-AUG-09) - 14
LOADING REPORT
CAPTION TELEX TREATMENT DATE :
5/5/2009
TANKER NAME :
SK SPLENDOR
CAPITAL
SUR, OMAN
(NO COUNTRY ex : Idku)
OF039/09-SL100-KG
CAPITAL
PORT :
CARGO REFERENCE NUMBER :
DD/MM/YYYY
1.QUALITY: ----------
INPUT CELLS FORMS AAAAAA TO BE ADJUSTED (drop-down list) (depending on operation, reference temperature...)
VOLUMETRIC/METERING REFERENCE TEMPERATURE (for calculations) : COMBUSTION REFERENCE TEMPERATURE (for calculations) : REFERENCE PRESSURE :
LNG CARGO COMPOSITION MESURED ON OPERATION
60 60 14.7
PSIA
459.080
KG/M3 (GNL)
1166
mbar
-128.5
°C
COMPONENTS METHANE : ETHANE : PROPANE : ISOBUTANE : NORMAL BUTANE : ISOPENTANE : NORMAL PENTANE : NORMAL HEXANE : NITROGEN : CARBON DIOXIDE : MERCURY : HYDROGEN SULFIDE : MERCAPTAN : TOTAL SULFUR :
90.24 5.95 2.24 0.69 0.58 0.02 0 0 0.28 0
AVERAGE TEMPERATURE OF LNG DELIVERED :
-160.2
UNIT % % % % % % % % % % ng / Nm3 mg / Nm3 mg / Nm3 mg / Nm3 LNG DENSITY (@ observed Temp) : °C
LNG GROSS CALORIFIC VALUE (MASS) :
54.44
MJ / kg (@15°C)
VAPOUR GROSS CALORIFIC VALUE (VOLUME) :
1115
BTU / SCF (@60/60°F)
WOBBE INDEX :
1411
BTU / SCF (@60/60°F)
404.978 136,292.944 135,888.000 62,172,077 62,172,077 3,207,380
UNIT M3 (GNL) M3 (GNL) M3 (GNL) KG KG MMBTU (@60°F)
11,130
MMBTU (@60°F)
VAPOUR AVERAGE PRESSURE : VAPOUR AVERAGE TEMPERATURE :
2.QUANTITY : ---------INSPECTOR FIGURES ( WITHOUT COOLING DOWN AND GASSING UP IF ANY) VOLUME BEFORE OPERATION : VOLUME AFTER OPERATION : TOTAL VOLUME DELIVERED : GROSS MASS DELIVERED : NET MASS DELIVERED (less gas return & ship consumption) : TOTAL ENERGY DELIVERED (less gas return & ship consumption) : ENERGY OF GAS RETURN :
3.STATEMENT OF FACTS : -----------------END OF SEA PASSAGE : ARRIVAL AT ANCHOR AREA : PILOT ON BOARD : BERTHING COMPLETED : NOTICE OF READINESS TENDERED : NOTICE OF READINESS RECEIVED : OPEN CUSTODY TRANSFER COMPLETED : OPERATION COMMENCED (1rst pump) : OPERATION COMPLETED : CLOSING CUSTODY TRANSFER COMPLETED : DOCUMENTS ON BOARD : VESSEL DEPARTURE : ETA NEXT PORT : NEXT PORT CALL :
5/5/2009 2:30 5/5/2009 2:30 5/5/2009 2:30 5/5/2009 2:30 5/5/2009 2:30 5/5/2009 2:30 5/5/2009 2:30 5/5/2009 2:30 5/5/2009 2:30 5/5/2009 2:30 5/5/2009 2:30 5/5/2009 2:30 5/5/2009 2:30 BONNY ISLAND, NIGERIA
4.OBSERVATIONS : ----------Delay before berthing / Delay before loading / Stops during loading / etc...
DD/MM/YY HH:MM DD/MM/YY HH:MM DD/MM/YY HH:MM DD/MM/YY HH:MM DD/MM/YY HH:MM DD/MM/YY HH:MM DD/MM/YY HH:MM DD/MM/YY HH:MM DD/MM/YY HH:MM DD/MM/YY HH:MM DD/MM/YY HH:MM DD/MM/YY HH:MM DD/MM/YY HH:MM (NO COUNTRY ex : MONTOIR)
COOLING DOWN + GASSING UP QUANTITY IF APPLICABLE VOLUME : ENERGY USED : (COOLING DOWN + GASSING UP)
0.000 0
UNIT M3 (GNL) MMBTU (@60°F)
OUR REF
: SUR/09/134
YOUR REF : OF039/09-SL100-KG
SAILING SUMMARY REPORT VESSEL : SK SPLENDOR TERMINAL/PORT : OMAN LNG / SUR, OMAN 1. TIME LOG DATE 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 11-May-2009 12-May-2009 12-May-2009 12-May-2009 12-May-2009 12-May-2009 12-May-2009 12-May-2009
HOUR 06:30 07:00 08:15 08:45 08:45 09:00 09:05 09:10 09:35 10:40 10:45 10:54 11:05 12:12 20:13 20:23 20:33 22:20 09:20 09:46 10:53 11:10 11:54 13:15 13:45
2. QUALITY COMPONENTS METHANE ETHANE PROPANE ISO BUTANE N-BUTANE ISO PENTANE N-PENTANE & HEAVIER NITROGEN CARBON DIOXIDE HYDROGEN SULFIDE TOTAL SULFUR
DATE
EVENT VESSEL END OF SEA PASSAGE PILOT ON BOARD FIRST LINE ASHORE NOTICE OF READINESS TENDERED VESSEL ALL FAST COMMENCED PRE-LOAD KEY / SAFETY MEETING BETWEEN VESSEL & TERMINAL COMMENCED CONNECTION OF CARGO & VAPOR ARMS NOTICE OF READINESS ACCEPTED COMPLETED CONNECTION OF CARGO & VAPOR ARMS COMPLETED PRE-LOAD KEY / SAFETY MEETING BETWEEN VESSEL & TERMINAL COMPLETED TESTING OF E.S.D. (WARM CONDITION) COMPLETED OPENING CUSTODY TRANSFER INSPECTION COMPLETED OPENING CUSTODY TRANSFER CALCULATIONS COMMENCED COOL DOWN OPERATIONS OF CARGO ARMS & SHIP'S TANKS COMPLETED COOL DOWN OPERATIONS OF CARGO ARMS & SHIP'S TANKS COMPLETED TESTING OF E.S.D. (COLD CONDITION) COMMENCED LOADING OF CARGO VESSEL REACHED FULL LOADING RATE VESSEL COMMENCED REDUCTION OF LOADING RATE COMPLETED LOADING OF CARGO COMPLETED CLOSING CUSTODY TRANSFER INSPECTION COMPLETED CLOSING CUSTODY TRANSFER CALCULATIONS COMPLETED DISCONNECTION OF CARGO & VAPOR ARMS DOCUMENTS ON BOARD DOCUMENTATION COMPLETED
METHOD GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261 GPA 2261
SPA SPECIFICATIONS NOT LESS THAN 85 % NOT MORE THAN 8 % NOT MORE THAN 3 %
RESULTS UNITS 90.24 mol % 5.95 mol % 2.24 mol % 0.69 mol % 0.58 mol % 0.02 mol % 0.00 mol % 0.28 mol % 0.00 mol % N/A mg / Nm3 N/A mg / Nm3
NOT MORE THAN 2 %
NOT MORE THAN 1 % NOT MORE THAN 5 mg / Nm3 NOT MORE THAN 30 mg / Nm3
3. QUANTITY LIQUID LNG VOLUME ON BOARD BEFORE LOADING LIQUID LNG VOLUME ON BOARD AFTER LOADING LIQUID LNG VOLUME LOADED LNG DENSITY AT -160.2 °C GROSS CALORIFIC VALUE (VOLUME) AVERAGE TEMPERATURE OF LIQUID AFTER LOADING MASS DELIVERED (Liquid Delivered - Vapor Return + Consumed as Fuel) QUANTITY DELIVERED (Liquid Delivered - Vapor Return + Consumed as Fuel) GAS-UP QUANTITY COOL DOWN QUANTITY BEST REGARDS
: 12-May-2009
: : : : : : : : : :
404.978 136,292.944 135,888.000 459.080 1115 -160.2 62,172.077 3,207,380 0 0
CUBIC METERS CUBIC METERS CUBIC METERS kg / m3 BTU / SCF °C METRIC TONS MMBTU MMBTU MMBTU
PONNAPPA CHOKIRA CSR 5 - Chubu Sailing Summary Report
LNG-LD-009H1 (07-AUG-09) - 14