MINI-THERM Gas-Fired Residential Hydronic Boilers
Reliable, Efficient and Quiet
The Compact Mini-Therm For Superb Home Heating Comfort TM
LAARS MINI-THERM gas-fired
service jacket, low-mass heat
Natural or propane gas models
residential hydronic boiler is the
exchanger and a super-quick
are available for all ignition types
ideal heating appliance that saves
heating response to meet your
are capable of higher efficiencies -
home owners money on heating
residential application
even at high altitudes.
costs and has plenty of capacity to
requirements. Ideal for new
keep even the largest home
homes or replacement boilers, the
Mini-Therm boilers offer
comfortable on the coldest days.
Mini-Therm boiler operates
exceptional value with “high
The compact boiler comes in three
efficiently to save energy and
performance hydronics” that give
varieties (JVT-standing pilot, JVS-
minimize utility bills, and is very
customers the highest
spark ignition, and JVH-hot
compact, to save space. It's also
performance at the lowest cost.
surface ignition with induced
easy to install, and its reliability
By far, Mini-Therm is the right
draft) to meet your installation
has been proven in the field over
solution for any size residential
needs... and your budget.
many years to give you years of
home heating system.
heating comfort and excellent Newly improved Mini-Therm,
dependability.
features an attractive and easy-to-
Mini-Therm Features • Attractive, new easy-to-service jacket • Compact design = small footprint
Water In
Built-in Draft Diverter
Relief Valve Water Out
• Six sizes: 50, 75, 100, 125,160 & 225 to suit any home • Copper-finned tube heat exchanger with cast iron “wet walls” • On/Off or 2-Stage firing modes (varies by model) • Up to 84% AFUE • Optional circulating pump
Copper Finned Tubes
Gas In Gas Valve
Cast-Iron "Wet Wall"
Drain Hose Bibb Connection
Burner
• Several venting choices include side-wall or chimney options • Easy to install
The Right Solution for Home Heating Systems
Mini-Therm JV that 2-Stage firing allows the unit to match the heating load requirement, reducing shortcycling in homes that have small heating zones that don’t require the full boiler capacity… another way to save energy.
Extremely popular with homeowners, JVT & JVS models offer a new attractive and easy-toservice jacket. Well-known for their economy, both models come with a built-in draft diverter and automatic vent damper to stop your valuable fuel payments from disappearing up the chimney in wasted heat. JVT-standing pilot ignition models use single-stage, on/off firing modes for all six sizes. JVS-spark ignition models also use the on/ off mode for the two smaller sizes JVT JVS Size 50 75 100 125 160 225
Input BTU/h x 1000 50 75 100 125 160 225
kW 14.6 21.9 29.1 36.6 46.8 65.9
JVT & JVS Features: • Standing pilot (JVT) or intermittent spark (JVS) ignition • Up to 84.4% AFUE (50 & 75), but offer energy saving “Low/High” firing for sizes 100, 125, 160 & 225. The advantage is
JVT Firing Mode On/Off On/Off On/Off On/Off On/Off On/Off
JVS Firing Mode On/Off On/Off 2-Stage 2-Stage 2-Stage 2-Stage
Heat Capacity BTU/h x 1000 kW 42 12.3 63 18.5 84 24.6 105 30.8 134 39.3 189 55.4
• Single stage on/off & 2-Stage firing modes • Sleek jacket removes easily for quicker service
Net IBR BTU/h x 1000 kW 36.5 10.7 54.8 16.1 73.0 21.4 91.3 26.8 116.9 34.3 164.3 48.1
JVT
JVS
AFUE % AFUE % 80.2 84.4 80.5 84.0 80.7 82.0 80.7 81.9 81.0 80.2 81.5 81.8
Mini-Therm JVi Mini-Therm JVH uses an H.S.I. (hot surface ignition system) to operate all six sizes in singlestage, on/off firing modes. The boiler is equipped with a draft blower that permits side-wall or chimney venting. Compact models are also easy to install, operate and maintain.
JVH Size 50 75 100 125 160 225
Input BTU/h x 1000 50 75 100 125 160 225
JVH Features: • Hot surface ignition system • Up to 83% AFUE • Single-stage on/off firing mode • Induced draft system with gravity operated vent damper
Firing kW 14.6 21.9 29.1 36.6 46.8 65.9
Mode On/Off On/Off On/Off On/Off On/Off On/Off
Heat Capacity BTU/h x 1000 41.5 62.3 82 102.5 131.2 184.5
Net IBR kW 12.1 18.2 24 30 38.4 54
BTU/h x 1000 36.1 54.2 72.6 89.6 114.1 160.4
AFUE kW 10.5 15.8 21.3 26.7 33.4 46.9
% 83.4 83.2 82.4 82.4 82.3 82.2
Mini-Therm JV
V Vent Damper (optional in Canada)
Draft Diverter
Vent Damper Harness 1-1/4 NPT
D
A/2
In (Return) PRV
Front
B
7 18
9-1/4 24
C
Out (Supply) T&P Gauge
Left
23-5/8 60
Top
Dimensions shown in inches cm.
E
JVT JVS Size 50 75 100 125 160 225
A
B
Dimensions D
C
E
F
inches cm
inches cm
inches cm
inches cm
inches cm
13-3/8 13-3/8 16-7/8 16-7/8 20-3/8 25-5/8
27-3/4 27-3/4 28-3/4 28-3/4 28-3/4 31-1/2
23-5/8 24-1/8 24-1/8 23-5/8 23-5/8 23-1/4
21-3/4 21-3/4 22-3/4 22-3/4 22-3/4 24-3/4
26-1/2 27-1/2 27-1/2 27-1/2 27-1/2 27-1/2
34 34 43 43 52 65
71 71 73 73 73 80
60 61 61 60 60 59
55 55 58 58 58 63
A
67 70 70 70 70 70
V
inches cm
18 18 18 18 18 20
46 46 46 46 46 51
Water Gas Conn. Conn.
inches cm
4 5 5 6 6 7
10 13 13 15 15 18
Approx. Weight
in.
in.
lbs.
kg
1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4
1/2 1/2 1/2 1/2 1/2 1/2
120 126 134 138 164 181
54 57 61 63 74 82
Mini-Therm JVi
Front
Right
Dimensions shown in inches cm.
JVH Size 50 75 100 125 160 225
Dimensions B
A
C
Water Conn.
Gas Conn.
Approx. Weight
inches
cm
inches
cm
inches
cm
inches
inches
lbs.
kg
13-3/8 13-3/8 16-7/8 16-7/8 20-3/8 25-5/8
34 34 43 43 52 65
3-1/8 4-1/4 5-3/4 5-1/2 7-1/4 10
8 11 15 14 18 25
2-7/8 2 2-7/8 2 2 2
7 5 7 5 5 5
1-1/4 1-1/4 1-1/4 1-1/4 1-1/4 1-1/4
1/2 1/2 1/2 1/2 1/2 1/2
160 165 180 185 210 225
73 75 82 84 99 102
20 Industrial Way, Rochester, NH 03867 • 603.335.6300 • Fax 603.335.3355 1355 Kuehner Drive, Simi Valley, CA 93063 • 800.900.9276 • Fax 800.559.1583 (Sales, Service) 480 S. Service Rd. West, Oakville, Ontario, Canada L6K 2H4 • 905.844.8233 • Fax 905.844.2635 A subsidiary of BRADFORD WHITE Corporation
www.Laars.com
Litho in U.S.A. © Laars Heating Systems 0508 Document 1086H