Dynamic Infrastructure Leadership Center Energy Efficiency

Alexandre CHABROL IT Specialist PSSC, Montpellier [email protected]

© 2009 IBM Corporation

Agenda  Green Concepts  Energy Efficiency Showcase

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

How is energy typically used in the data center? Data center

Server hardware

45%

70%

X2,2

30%

Power supply, memory, fans, planar, drives . . .

Power and Cooling

35 W data center

Resource usage rate

Processor

IT Load

55%

Server loads

16 W equiv IT power

x3

5 W equiv processor

80%

20%

Idle x5

+1 W equiv. used ressource

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

Project ‘Big Green’ • IBM to reallocate $1 billion each year: – To accelerate “green” technologies and services – To offer a roadmap for clients to address the IT energy crisis while leveraging IBM hardware, software, services, research, and financing teams – To create a global “green” team of almost 1,000 energy efficiency specialists from across IBM

• Re-affirming a long standing commitment at IBM: – Energy conservation efforts from 1990 – 2005 have resulted in a 40% reduction in CO2 emissions and a quarter billion dollars of energy savings – Annually invest $100M in infrastructure to support remanufacturing and recycling best practices – Will double compute capacity by 2010 without increasing power consumption or carbon footprint saving 5 billion kilowatt hours per year . . . equals energy consumed by Paris “the City of Lights”

• What “green” solutions can mean for clients: – For the typical 25,000 square foot data center that spends $2.6 million in power annually, energy costs can be cut in half – Equals the reduction of emissions from taking 1,300 automobiles off of the road

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

Environmental Friendly New Goal Announced!

Awards & Recognition FORTUNE 500 Top 20 2004, 2005, 2006

Further extend IBM’s early

The Climate Group 2005

1998, 1999, 2001

accomplishments by reducing

USEPA Climate Protection Award 1998 and 2006

2005 2005

CO2 emissions associated with

Green Power Purchaser Award 2006

IBM’s energy use 12% from 2005 to 2012 via energy conservation, use of renewable energy, and/or funding CO2 emissions

Environmental Efforts at Big Blue Computer Program Charter Member 1992

Charter member 2003

Charter Member 2000

reductions with Renewable WRI Green Power Market Development Group Charter member 2000

Energy Certificates or comparable instruments.

Business Environmental Leadership Council

1605(b) voluntary emissions reporting since 1995

Charter Member 2002 Since inception

Early Results

600 500

1998

Became the first semiconductor company to set a numerical target for PFC emissions reduction

400

40%

Between 1990 and 2005, IBM’s global energy conservation actions reduced or avoided CO2 emissions by an amount equal to

40% of its 1990 emissions.

300

58%

200 100 0 2000

2001

2002

2003

2004

2005

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

First, To assess Energy Efficiency of its Data center  Compares total power used by the data center to the power used by the technology  Provides a marketplace comparison  Demonstrates range for opportunity improvement

PUE Least energy- efficient

Most energy efficient

Objective

1.0

1.5

Current

2.0

2.5

3.0

3.5

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

Dynamic Infrastructure Leadership Center Energy Efficiency What is demonstrated in the showcase

© 2009 IBM Corporation

DI Leadership Center - Energy Efficiency: The Overall Concept  Build the most innovative global Energy Efficiency Customer showcase leveraging the biggest European ITD Strategic & PSSC Data Centers

Vision

Objectives  Design and build the “Energy Efficiency Showcase” with the latest STG technology • Show enhancements and strengths of each component of the latest technology

STG Focus

The full Green DC Story

WW project

Be utilized by the DI Leadership Center. Focus on STG plays: Virtualization, Consolidation, Energy Efficiency, Serviceability, Resiliency& Security Create STG assets Detect & validate for Customers opportunities Run a real production Data Center showcase for customers, partners and IBMers Demonstrate the global Green Data Center solutions : • IBM credibility on Data Center « sell what we use & use what we sell » • Leading edge solutions and directions to the energy & cooling challenges • Best practices in Data Center Management  Be a Customer reference  Develop STG partnership with SWG, GTS, ITD/SO and Industries

     

 Share PSSC MOP as part of the WW project including POK and BJG  Provide WW sales forces a tremendous tool to start engaging with their customers on DC pain points  Be the innovative WW leader on the market place

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

Green Data Center Specifications

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

From the Green Data Center

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

High Density Zone  SMDC – APC Schneider Air Cooled – 2 IT racks  SMDC – APC Schneider Water Cooled – IT 6 racks  iDataPlex and Rear Door.

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

Low Density Zone  IBM Hardware portfolio (Servers & Storage)  Hot and Cold aisles  Pastic curtains

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

Live Camera The PUE is affected by any physical access into the room. Having a live sophisticated camera can reduce the physical accesses. Synapsense probes & sensors

Raised floor tile for behind z10

For demo purpose, it helps to remotely present the technologies to our customers.

The High Density Zone The technical zone: the CRACs DI Leadership Center Energy Efficiency © 2009 IBM Corporation

LAS Location Awareness Services - LAS & Ubisense IBM LAS Solution helps to track humans and assets. Rules can be applied and alerts sent. For demo purpose you can see and track people entering into the room. When rules are violated, you can either see alerts in LAS or Tivoli.

A human stay too long in the warm corridor. Alert is positioned and sent to Tivoli ITM.

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

Synapsoft and Synapsense probes and sensors

150 probes and sensors allowing to monitor real time: the temperature, pressure and humidity in the DC.

For demo purpose all the measurement can be graphically shown. Helping to efficiently track hot spots and DC behavior.

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

Thermal Camera This very technological advanced camera can show hot spots in a Data Center. For demo purpose you point the camera to any DC components and graphically visualize the temperature of it.

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

Modelization of the Data Center in Second Life The Green Data Center has been modelized. Air flows and technologies can presented and explained. For demo purpose you can meet us at the PSSC SL building and we will bring you or your customer (avatar) into the Data Center.

A FUN EXPERIENCE.

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

TIVOLI TEP Workplaces

DI Leadership Center Energy Efficiency © 2009 IBM Corporation

PSSC Data Center Improvements PSSC GDC PUE

33% Energy Saving 3  Mainly on the Non-IT.

2,5 2,5 PSSC IT already consolidated and virtualized. IT: 700MW Non-IT:1.05 1.75GW 2 1,9 GW per year: Savings per year 1,65 1,5

 590MW

IT: 700MW 1.33GW 1 Non-IT: 630 MW  35400€. 2007 per year 2008

2009

1.16GW Average of 354€ per sqm. IT: 700MW perkWph: year Non-IT: 416MW 0,06€ DI Leadership Center Energy Efficiency © 2009 IBM Corporation

Dynamic Infrastructure Leadership Center Energy Efficiency  Contact PSSC Montpellier +33(0)4 6734 6366  Luc Colleville  Dynamic Infrastructure Manager  [email protected]

 Emmanuel Tong-Viet  Energy Efficiency SME  [email protected]

 Dr. Jean-Michel Rodriguez  Energy Efficiency WW Lead Architect  [email protected]