Which term describes two or more interconnected nodes that present a single virtual server to the network? A.

cluster

B.

NIC team

C.

multipathing

D.

fault tolerance

Which storage infrastructure typically uses file level data access? http://www.dvinfo.net/conf/open-dv-discussion/60726-nas-vs-san-file-vs-blocklevel-data-access.html A.

Internet SCSI

B.

storage area network

C.

direct attached storage

D.

network attached storage

You are at a customer site to repair an HP StorageWorks 1200 All-in-One (AiO) Storage System in a redundant AiO environment. Which data replication solution can be implemented to replicate data between the two AiO systems? http://h71028.www7.hp.com/ERC/downloads/4AA10068enw.pdf A.

HP StorageWorks Storage Mirroring

B.

HP Continuous Access for SMB storage

C.

HP Data Replication Manager for NAS products

D.

HP StorageWorks Fast Recovery Solution 2003 AiO

Which networking technology includes network failover? A.

NIC Teaming

B.

TCP Offload Engine

C.

multi-protocol bridging

D.

Network Acceleration Cards Which solution enables a customer to maintain a continuous replica of data on a second storage server? http://h18000.www1.hp.com/products/storage/software/sm/index.html

A.

Microsoft Cluster Service

B.

HP OpenView Data Protector

C.

Volume Shadow Copy Service

D.

HP OpenView Storage Mirroring What is the primary difference between HP ProLiant Storage Servers and standard ProLiant servers? A.

Standard ProLiant servers cannot attach to SAN storage.

B.

HP ProLiant Storage Servers integrate SATA drive shelves.

C.

Standard ProLiant servers have a different system bus architecture and use different processor types than HP ProLiant Storage Servers.

D.

HP ProLiant Storage Servers have a storage specific management interface (WebUI or MMC) and use Windows Storage Server 2003 R2.

What are advantages of HP Storage Server products? (Select two.) A.

HP Storage Server products offer in-box upgrades for NAS environments.

B.

HP offers 24x7 hardware and software support for its SMB NAS products as standard.

C.

The HP Storage Server product line offers products designed solely for SMB customers.

D.

HP offers DFS capabilities without the need for additional servers in the NAS environment.

E.

HP Storage Server NAS solutions support native anti-virus software that can run directly on the ProLiant Storage Server.

While using the HP Array Configuration Utility to configure array based storage from WebUI, you notice two logical drives pre-configured under Array A on the first controller. What is their purpose? A.

They are part of a default fault tolerant configuration on logical unit basis.

B.

They are used to temporarily expand array capacity automatically as required.

C.

They are configured for the storage server operating system and should not be altered.

D.

They were created by the configuration wizard and may be used to

easily duplicate volume configurations. Which functions does the Storage Management page provide a portal to? (Select two.) http://h18000.www1.hp.com/products/storageworks/sb460c/qa.html A.

indexing service

B.

SIS management

C.

DFS management

D.

share management

E.

backup management

You are adding additional external storage to an AiO400 storage system. Which external storage is supported? http://h18000.www1.hp.com/products/quickspecs/12785_div/12785_div.pdf A.

1 MSA20 shelf

B.

1 MSA30 shelf

C.

2 MSA20 shelves

D.

2 MSA30 shelves

Which statement is true regarding the installation of an HP AiO SB600c? http://h20000.www2.hp.com/bc/docs/support/SupportManual/c01181417/c0118141 7.pdf

g u r e t h e b l a d e s u s i n g O n b o a r d A d m i n i s t r a t o r v e r s

Which new software products are included in Windows Storage Server 2003 R2? (Select two.) http://www.microsoft.com/windowsserversystem/wss2003/productinformation/feat ures/default.mspx A.

iLO2 support

B.

AppleTalk support

C.

Services for Unix 3.5

D.

Single-instance Storage

E.

Storage Manager for SANs Which HP ProLiant Storage Servers have been optimized as Data Protection Storage Servers? (Select two.) http://h20000.www2.hp.com/bizsupport/TechSupport/Home.jsp?lang=en&cc=us& prodTypeId=12169&prodSeriesId=1143888&submit.y=9&submit.x=7&lang=en&c c=us A.

DL585 G2

B.

DL100 G2

C.

DL380 G5

D.

DL320 G2

E.

ML350 G5 How is RAID capability implemented in the HP ProLiant Storage Server DL380 base model? A.

A SCSI storage array controller is integrated on the system board.

B.

A storage array controller must be added to enable RAID capability.

C.

A storage array controller in a PCI slot is part of the standard configuration.

D.

An external Fibre Channel RAID controller is strongly recommended for all disk drives. Which defaults are used for the WebUI login? A.

user: hpinvent, password: Administrator

B.

user: Administrator, password: hpinvent

C.

user: administrator, password: administrator

D.

user: Administrator, password: Administrator The HP All-in-One Management Console provides access to which File Server Resource Manager (FSRM) tasks? (Select three.) http://technet.microsoft.com/en-us/library/cc755603.aspx

A.

quota management

B.

share management

C.

storage management

D.

antivirus management

E.

file screening management

F.

data protection management

Which methods can be used to access the All-in-One Management Console? (Select two.) http://data.versiontracker.com/drivers/autoExtract/hp/ftp1/pub/softlib2/software1/c d/p691616582/v48751/ServiceRelease_pss_x32_6.9_ext/extract/ReadMe/AiO/EN/Re adMe.txt A.

Telnet

B.

Remote Desktop

C.

HP integrated Lights-Out 2

D.

remote browser using Internet Explorer 6.0 (or higher)

E.

serial cable directly connected to the rear of the AiO server

Which tools are provided by the Storage Server Management portal? (Select two.) A.

SAN Management

B.

DFS Management

C.

OVMS Management

D.

Cluster Management

E.

Provisioning Management

You must update a NAS device from Windows Storage Server 2003 SP1 to Windows Storage Server 2003 R2. How should you connect to the server to perform this upgrade? (Select two.) A.

Internet Explorer

B.

Windows Remote Desktop

C.

direct connection to the server

D.

Windows Terminal Services session

E.

integrated Lights-Out (iLO) Remote Desktop

Which product key must be used when performing the Windows Storage Server 2003 R2 upgrade? A.

the current activation key

B.

No activation key is required.

C.

the new one supplied with the upgrade kit

D.

any activation key from other storage server upgrades

You installed a new network printer and as a result you are updating the printer driver on an AiO storage system using the Service Release DVD. Where are these drivers copied? A.

C:\hpnas\drivers

B.

C:\windows\printers

C.

C:\windows\system

D.

C:\windows\system32\drivers

You installed the HP Network Teaming utility. What must you do to ensure proper functionality? A.

Restart the storage server.

B.

Enter default DHCP addresses.

C.

Change the username and password.

D.

Disable the NICs in Windows Device Manager.

When managing an HP ProLiant Storage Server by a remote desktop session, that must you do to close any active tasks? http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc =us&taskId=115&prodSeriesId=3355757&prodTypeId=12169&objectID=c01047 984#A16 A .

l o g o f f

B .

s h u t d o w n

C .

d i s c o n n e c t

Which statement is correct regarding field replaceable units of the HP ProLiant DL100 G2 Storage Server? A.

The IDE hot-swap hard disk is the only field replaceable unit.

B.

HP ProLiant DL100 G2 Storage Server has no field replaceable units.

C.

RAM, DVD-ROM, RAID controller, and fan modules are field replaceable units.

D.

CPU, RAM, DVD-ROM, RAID controller, fan modules, and power supplies are field replaceable units.

What do you do to recover disk space when snapshots have been created by Persistent Storage Manager (PSM) or VSS after a quick recovery? http://www.cdp.com/library/EngineeringDoc.pdf A.

Orphaned snapshots must be deleted manually.

B.

The disk space must be recovered by editing the correct registry key.

C.

Orphaned snapshots can be recovered using the Array Configuration Utility.

D.

Arrays must be recreated and the orphaned snapshots will automatically re-attach to the parent

If you replace a processor and the new one has a higher speed, what should you do first? A.

Upgrade the cache on the RAID controller.

B.

Upgrade the power supply to the higher speed option.

C.

Install the HSP (High Speed Processor) feature pack.

D.

Update the system ROM before installing the processor When you insert a drive in an HP ProLiant Storage Server, it flashes for two seconds. What does this indicate? A.

The drive is experiencing connectivity errors.

B.

Drive firmware is calculating the disk capacity.

C.

The drive is seated properly and receiving power.

D.

The internal drive cache is flushing data to the platters.

What must you do to recover the shares of an HP ProLiant Storage Server that needs a Quick Restore performed on it? i c k r e s t o r e p r o c e s s .

D .

S a v e t h e S Y S T E M \ C u r r

You are replacing a non hot pluggable component in an HP Proliant Storage Server with external storage. What must be powered down first?

A .

d i s k d r i v e s

B .

s t o r a g e s e r v e r

C .

E t h

Item 41 of 60

Mark item for review

After a power failure, you are asked to replace the power supply of an HP Storage Server 1200s. Which statement is correct? http://h18000.www1.hp.com/products/quickspecs/11829_div/11829_div.HTML o u c a n r e p l a c e t h e f a i l e d p o w e r s u p p l y .

What is the standard power supply configuration of an HP ProLiant DL100 Storage Server?http://h20195.www2.hp.com/PDF/DA-12340.pdf A.

a single module with UPS

B.

a single module without UPS

C.

dual modules, hot swap capability

D.

dual modules, no hot swap capability

Which statement is correct about using the persistent image as a replacement for backup and disaster recovery? http://h20000.www2.hp.com/bizsupport/TechSupport/Document.jsp?lang=en&cc=us &taskId=115&prodSeriesId=341801&prodTypeId=12169&objectID=c00054469 A.

The persistent image cannot be a replacement for backup and disaster recovery.

B.

Persistent images are suitable for disaster recovery, but do not replace backup.

C.

For disaster recovery, the persistent image should not be placed on the same volume as the live data.

D.

Since persistent images reside on different disks than the original data, they should be used for backup and disaster recovery.

What must you do to delete a RAID logical device in Adaptec Storage Manager (ASM) when the partitions were deleted using Windows Disk Manager with ASM open? A.

Rescan the controller in Adaptec Storage Manager.

B.

Rescan the controller bus in Windows Disk Manager.

C.

Recreate the partitions and delete them in Adaptec Storage Manager.

D.

Reboot the server and rebuild the partitions in Windows Disk Manager.

A customer reports serious performance problems on an HP Storage Server cluster when a failover occurs. Without hardware failure problems, what can

cause this degraded performance? A.

The disk space is insufficient.

B.

The memory capacity is insufficient.

C.

Both nodes are running at 80% resource usage in normal operation.

D.

A large amount of the available resources were allocated for the failover event analysis.

What informs a user about a drive failure during boot of an HP ProLiant 1x0 series Storage Server? A.

a new system event log file entry

B.

an audible alert from the Adaptec controller

C.

a message displayed at the Operator Control Panel

D.

an email notification from the integrated lights-out module A network interface controller (NIC) in an HP ProLiant Storage Server is suspected to be faulty. Which basic TCP/IP utility do you use to verify that the NIC is online? A.

ping

B.

ping

C.

nslookup

D.

ipconfig <MAC address> In an environment where a system is expected to be up continually, how should you prepare an HP ProLiant Storage Server for recovery after a disaster ? http://www.hp.com/hpinfo/newsroom/press/2006/060524xa.html A.

Use disk imaging.

B.

Use tape backup.

C.

Use a set of recovery DVDs.

Where can you access the Array Diagnostic Utility? http://www.governmentsecurity.org/articles/articles2/375445-002.pdf_fl/375445002-70.html A.

SmartStart CD

B.

Insight Manager

C.

Array Controller Utility

D.

Storage Server Management Console A customer reports that a certain client loses the connection to a cluster service when a failover occurs. What is the most probable cause? A.

The network connection is unstable.

B.

The connection timeout interval is too short.

C.

The failover mechanism terminates the cluster services.

D.

The client is using the node name rather than the cluster name

Which statement about defragmentation operations for volumes with shadow copies is correct? http://smallvoid.com/article/winnt-services-vss.html

a n r e s u l t i n l o s s o f l i v e d a t a f o r t h e v o l u m e .

Where will you find the MIB files for the SNMP suite on the HP ProLiant Storage Server? A.

MIB share

B.

SNMP share

C.

SSMIB directory

D.

HPNAS directory

What can you attach to execute a local loopback test on a network interface controller? A.

network sniffer

B.

HP network switch

C.

loopback connector

D.

Time Domain Reflectometer What happens after replacing the clock battery in an HP ProLiant Storage Server? A.

The real-time clock is disabled.

B.

System clocks run at maximum speed.

C.

System ROM is reset to its default configuration.

D.

The message Adjust date and time displays at power-on You are replacing a processor on an HP ProLiant Storage Server. What must be between the new CPU and the heatsink cooling fan? A.

1 mm gap

B.

antistatic membrane

C.

special contact adhesive

D.

thermal grease compound

What does the Windows Storage Server Quick Restore CD restore? http://www.bluedogink.com/hp-storageworks-nas-2000s-internal.html A.

user data

B.

default factory state

C.

storage configuration

D.

full configuration before the failure Using persistent images, the customer reports incomplete images. What is the most probable cause? A.

The disk is full.

B.

A concurrent backup job terminates image creation.

C.

A quiescence time less than 5 seconds can cause an incomplete image.

D.

System performance can be affected significantly and cause incomplete images.

You must perform diagnostics on a DL585G2 Storage Server. Where do you find the required HP Insight Diagnostics Offline Edition tool? http://h18013.www1.hp.com/products/servers/management/hpid/index.html?jum pid=servers/diags

A .

o n t h e S m a r t S t a r t C D

B .

o n t h e S y s t e

During a capacity upgrade on an HP ProLiant DL100 G2 Storage Server, the hard drive Online LED (green) and the Fault LED (amber) flash regularly. What does this indicate? http://bizsupport.austin.hp.com/bc/docs/support/SupportManual/c00667703/c00667 703.pdf A.

A faulty power supply caused a non-critical voltage decrease.

B.

A member disk of a redundant RAID array failed and no spare disk is available.

C.

A predictive failure alert has been received; the disk should be replaced immediately.

D.

A predictive failure alert has been received from a member disk of a redundant RAID array; data migration is in progress.

What is a feature of RAID 6 (ADG)? http://h18000.www1.hp.com/products/servers/proliantstorage/arraycontrollers/adg/ questionsanswers.html A.

stripes data across several RAID 1 sets

B.

uses two independent disks as a hot-spare resource

C.

allocates two sets of parity data across multiple drives

D.

allows three simultaneous drive failures without downtime or data loss Which software product is used with an HP ProLiant DL380 G5 Data Protection Storage Server to provide rapid and reliable recovery, near-continuous data protection, and operational simplicity for disk-based backup of Windows file servers? http://technet.microsoft.com/en-us/dpm/bb655872.aspx A.

HP StorageWorks Storage Mirroring

B.

HP Data Protector Express Software

C.

Microsoft Content Management Server

D.

HP Ultimate Business Protection Snap-In

E.

Microsoft System Center Data Protection Manager

What is the purpose of a NAS server? http://en.wikipedia.org/wiki/Network-attached_storage A.

aggregates network bandwidth across multiple area networks

B.

allows multi-network protocol to be routed across network segments

C.

performs the same role as a general file server, but also emulates multiple file systems

D.

provides a gateway protocol that allows SAN storage to be presented across Ethernet networks

Which HP PolyServe technology in the EFS Clustered gateway solution assures data integrity and cache coherency even when node failures occur? http://h18000.www1.hp.com/products/quickspecs/12585_div/12585_div.pdf A.

Matrix Volume Manager

B.

Virtual File Server (VFS) Cluster

C.

Symmetrical Cluster File System

D.

Enhanced Linux file serving environment

A customer requests cluster support for HP StorageWorks storage servers. Which Windows Storage Server 2003 edition supports clusters? http://h71028.www7.hp.com/ERC/downloads/5982-7017EN.pdf A.

Express

B.

Standard

C.

Enterprise

D.

Workgroup

Which member of the HP ProLiant Storage Server family provides cluster support along with redundant components? A.

DL100 G2

B.

ML310 G3

C.

ML370 G4

D.

DL380 G4 Which HP ProLiant Storage Server product line is designed for environments with a maximum of five servers connected using iSCSI and no

additional license requirements? A.

HP EFS

B.

All-in-One Storage

C.

HP Storage Server Gateway

D.

HP Storage Server NAS Filer

What is the maximum number of networked printers supported in the Windows Storage Server 2003 R2 Workgroup edition? http://forums13.itrc.hp.com/service/forums/questionanswer.do?admit=109447627+12263 24629774+28353475&threadId=1196452 A. 2 B.

3

C.

4

D.

5

You are integrating a NAS solution using Multifunction NICs at a customer site and you want to install the Microsoft Windows Server 2003 Scalable Networking Pack. Which resources can you use to obtain this software pack? (Select two.) http://support.microsoft.com/kb/912222 A. Microsoft website B.

HP Support website

C.

HP Bizsupport website

D.

HP ProLiant Support Pack

E.

Windows 2003 Service Pack 2

You are configuring HP StorageWorks All-in-One SB600c hardware in a C-Class blade enclosure. Which statement is true?

A.

In an odd-numbered bay, the partner server blade must reside in the adjacent, even-numbered bay to the left.

B.

In an even-numbered bay, the partner server blade must reside in the adjacent, odd-numbered bay to the right.

C.

In an even-numbered bay, the partner server blade must reside in the adjacent, even-numbered bay to the right.

D.

In an odd-numbered bay, the partner server blade must reside in the adjacent, even-numbered bay to the right.

What is the maximum memory supported in the Windows version of an HP DL385 G5 Clustered Gateway node? http://h18000.www1.hp.com/products/quickspecs/12585_div/12585_div.pdf A. 2GB B.

4GB

C.

16GB

D.

32GB

What is this symbol warning you about when it is on an HP ProLiant Storage Server?

Exhibit

The internal health LED of an HP StorageWorks 600 All-in-One storage system front panel is amber. What is indicated?

http://bizsupport.austin.hp.com/bc/docs/support/SupportManual/c01168568/c011 68568.pdf A.

a non-critical error

B.

critical system health

C.

degraded system health

D.

a power redundancy failure

More Documents from "Matthew Hyman"