Corning Cable Systems Solutions for Premises Networks

Copyright © 2005

All rights reserved. This publication must not be reproduced or copied in any way whatsoever without the express consent in writing of Corning Cable

Systems GmbH & Co. KG. All Corning Cable Systems products described in this catalog are subject to availability and technical modification. Corning Cable Systems GmbH & Co. KG reserves the right to improve, enhance or

otherwise modify Corning Cable Systems product without prior notification, including and in particular technical data and other information about such

products. There is no legal obligation to supply a specific product to a precise specification until a binding order is accepted by Corning Cable Systems GmbH & Co. KG.

Order No. EUR-221-EN Printed in Germany

Corning Cable Systems GmbH & Co. KG Rotherstrasse 21

10245 Berlin, Germany

LANscape® Solutions FutureCom™ Copper Products

Corning Cable Systems

LANscape® Solutions

FutureCom™ Copper Products Catalog Issue 1, EMEA

Corning Cable Systems

FutureCom E System

55

5

FutureCom D System

81

6

FutureCom UE System

101

7

FutureCom UD System

115

8

Hardware

127

9

Telephone / ISDN Products

165

10

Cable for Patch Cords

169

11

Industrial Cable

175

12

Special Cable

183

13

Further Information

205

Corning Cable Systems

1

FutureCom F

4

FutureCom 10TEN

41

FutureCom E

FutureCom 10 TEN System

FutureCom D

3

FutureCom UD FutureCom UE

13

Hardware

FutureCom™ F System

Flex Wire Cable Telephone / for Patch Cord ISDN Products

2

Industrial Cable

3

Special Cable

Introduction

Further Information

1

Introduction

Table of contents

LANscape and UniCam are registered trademarks of Corning Cable Systems Brands, Inc. FutureCom, FutureLink, Pretium, FutureCom 10TEN, LSZH and Plug & Play are trademarks of Corning Cable Systems Brands, Inc. Discovering Beyond Imagination is a registered trademark of Corning

Incorporated. All other trademarks are the properties of

their respective owners. Corning Cable Systems is ISO9001 and ISO 14001 certified.

2

Corning Cable Systems

4

1.2. Corning Quality

5

1.3. Corning Cable Systems Global Locations

6

1.4. Standards for Structured Cabling

8

1.5. System Description

9

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

1.5.1. LANscape® Structured Cabling

FutureCom F

1.1. Corning - A Reliable Partner

FutureCom 10TEN

3

FutureCom E

Introduction

Further Information

1

Introduction

Table of contents

Corning Cable Systems

3

Corning Quality Corning Incorporated is a diversified technology company

Corning’s own complete system for structured cabling, on

with a proud history of developing breakthrough technolo-

the basis of copper cable, followed in 1990. Since then, Corn-

years, integrating scientific discovery with market need. We

world, Corning started using 600 MHz technology for sym-

gies that significantly improve people’s lives. We have been

changing the world through innovation for more than 150

focus on high-impact growth opportunities in the telecommunications, flat panel display, environmental, life sciences and semiconductor industries.

Corning is a reliable partner that meets the communication requirements of its customers all over the world with costeffective solutions.

In 2000 Corning grouped all its cable, hardware and equipment businesses into the Corning Cable Systems division. Corning Cable Systems now comprises the former Siecor

Corporation, the communication cables business from BICC (Corning Cables), Siemens’ former Communication Cables

division and RXS Kabelgarnituren. Norddeutsche Seekabelwerke (NSW) also belongs to Corning Incorporated and is continuing to operate as a separate company.

ing has always been a market leader and the technology

leader for cabling systems. In 1995, for the first time in the metrical copper cabling systems.

Today, with LANscape® FutureCom™, Corning offers a com-

plete system of copper components with bandwidths of 100 to 1500 MHz and the experience of installing more than

15 million ports. This can also be combined with modular

fiber optic hardware and FutureCom™ cable components. LANscape - the combination of FutureCom™ copper and

fiber optic products - thus offers the optimal solution for every network.

Our quality and environmental management systems are

certified to DIN EN ISO 9001 and ISO 14001. Our global pres-

ence is your gain because, wherever you are, Corning is close at hand.

In the field of fiber optic cable technology, Corning was one of the original pioneers, with expertise second to none. As

early as 1974, when fiber optic technology was still in its in-

fancy, Corning was working with Europe’s leading Public

Telecommunications companies in developing trial fiber optic routes. The end of the 90s saw the beginning of local

networks on the basis of today’s network protocols - and

Corning was actively involved from the start.

4

Corning Cable Systems

Further Information

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

FutureCom 10TEN

Corning Cable Systems is committed to providing excellent product

Corning Cable Systems

5

Introduction

quality and customer support services. FutureCom F

Corning Quality

Corning Cable Systems Global Cable and Hardware Businesses

Whiston, Great Britain

Derby, Great Britain Aberdeen, Great Britain Deeside, Wales Headquarter, Hickory NC, USA

Favières, France Winston-Salem, NC, USA

Keller, TX, USA Santo Domingo, Dominican Republic

Reynosa, Mexico

Rio Grande, Puerto Rico Boca Raton, FL, USA

6

Corning Cable Systems

Madrid, Spain

Hagen, Germany Nordenham, Germany Berlin, Germany Neustadt, Germany Lodz, Poland

Munich, Germany Turin, Italy

Hickory, North Carolina, USA.

Corning Cable Systems EMEA Headquarters is located in

FutureCom E

FutureCom 10TEN

FutureCom F

Berlin, Germany.

Introduction

Corning Cable Systems Global Headquarters is located in

FutureCom D

Moscow, Russia

FutureCom UD FutureCom UE

Gebze, Türkei Tokyo, Japan

Amman, Jordan Bangkok, Thailand

Shanghai, China Makati City, Phillipines

Kuala Lumpur, Malaysia

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

Singapore, Singapore

Further Information

Special Cable

Industrial Cable

Clayton, Australia

Corning Cable Systems

7

Standards for Structured Premises Cabling Solutions The requirements of future-proof and flexible structured cabling are largely determined by three fundamental cabling standards addressing specific geographic regions:

Standard Europe

North America World

Description

EN 50173-1 (2003) Cabling Standard Information Technology

Generic Cabling Systems

TIA/EIA 568 B. 1 (2001) / B.2 1 (2001) Commercial Building Telecommunications

Cabling Standard

ISO/IEC 11801 Edition 2002 Cabling Standard, Generic Cabling for

Customer Premises

The TIA/EIA is not a standard as such, but an industry specification in the North American market. It also contains

requirements regarding the transmission characteristics of cabling and components that differ from those of the EN or ISO/ IEC. It has its origins in the specification of unshielded copper components.

Campus

Building

distributor

distributor Fiber

1500 m

Campus Backbone

8

Floor

distributor

Fiber (copper)

500 m

Telecommunication

Building Backbone

outlet

Copper / Fiber

Copper / Fiber

90 m

Horizontal Substystem

100 m incl. patch and connecting cords

Corning Cable Systems

Terminal

equipment

LANscape® Structured Cabling Building cabling can utilize cabling with both symmetrical copper cables and components and fiber optic cables and

one location with each other. The campus distributor forms

The cabling is installed in a star shape radiating out from

the center of primary cabling. Due to the relatively long

transmission paths, only fiber optic cabling is worth considering. Corning offers a fiber optic modular cabling solution

which can be combined with copper-component cabling systems. For the campus environment, mainly single-mode

fiber cable is used, which distinguishes itself by its low at-

tenuation and high bandwidth. A further argument for fiber optic cable in this area is its electromagnetic insensitivity.

Building Backbone

In the horizontal subsystem, mainly copper cable is used. the horizontal distributor to the individual connection

boxes. The distance, however, should not exceed 90 m, since

the cabling would then no longer comply with the standard. An additional option in the horizontal area is “fiber to the

desk” (FTTD), i.e. fiber optic cabling to the workstation. This is used for high bandwidth or long distance centralized cabling applications.

FutureCom UD FutureCom UE

Campus cabling (backbone) links the individual buildings in

FutureCom E

Horizontal Subsystem

FutureCom D

Campus Backbone

FutureCom 10TEN

FutureCom F

Introduction

components. In the primary area, only fiber optic cables and components are used.

The connection between the building distributor and the

various horizontal distributors is designated as the second-

ary area. It represents the backbone of the building. The cabling of the vertical area can be carried out with both symmetrical copper cables and fiber optic cables. “High-end”

copper data cable (bandwidths up to 1500 MHz), such as

Hardware

those you can find in the Corning FutureCom™ product

range, can also be used in the secondary area for lengths up

Flex Wire Cable Telephone / for Patch Cord ISDN Products

to 100 m.

For increased bandwidth requirements, fiber optic cables (generally multi-mode fiber cables) are recommended in

Further Information

Special Cable

Industrial Cable

this area for greater future security .

Corning Cable Systems

9

LANscape® Structured Building Cabling

Horizontal Subsystem:

FutureCom™ Outlets and Outlet Accessories (see pages 128-143)

10

Corning Cable Systems

Horizontal Subsystem:

FutureCom Data Cables S/FTP, F/FTP, SF/UTP, F/UTP or UTP

(see system chapters in this catalog)

Introduction FutureCom F

Horizontal Subsystem:

FutureCom Floor Distributors

19“ Patch Panels

(see pages 152-156 or the LANscapeFiber Optic

Campus Backbone – Backbone Cabling: Fiber Optic Cables

(see the LANscape Fiber Optic Catalog,

Building Backbone – Vertical Area Cabling:

(see pages 152-156 or the LANscape® Fiber Optic

in this catalog)

FutureCom 19“ Distribution Panels or 19“ Patch Panels

Catalog, EUR-220-EN)

Fiber Optic Cable or FutureCom S/FTP, F/FTP, SF/UTP, F/UTP (see the LANscape Fiber Optic Catalog or system chapters

Corning Cable Systems

11

Further Information

Building Backbone – Horizontal Distributor:

Special Cable

Industrial Cable

EUR-220-EN)

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

Catalog, EUR-220-EN)

FutureCom D

Campus Backbone – Building Distributor:

FutureCom E

FutureCom 10TEN

(see pages 144-151)

12

Corning Cable Systems

2.4.1. S1200 Modules and Connectors Overview

21

2.4. Connecting Hardware

2.4.2. Modules and Module Accessories

22

2.4.4. Tools

25

23

2.4.3. S1200 Connectors 2.5. Hardware

2.5.1. Outlets and Outlet Accessories

26

2.5.2. Floor Box Solutions

29

2.5.4. Consolidation Point Housing for S1200 Module

32

2.6.1. Cat. 7 Patch Cords

33

2.5.3. Patch Panels

31

2.6. Patch Cords

2.6.2. Cat. 6 Patch Cords

34

2.6.4. UTP Flex Patch PVC Cords

37

2.6.3. Cat. 5 Patch Cords

35

2.6.5. TV Connecting Cable

38

2.7. Plug & Play™

39

40

Special Cable

2.8. Test Adapter Cable

FutureCom F

18

FutureCom 10TEN

2.3.1. Cat 7. S/FTP 1500/22 and S/FTP 1200/22 Cables

FutureCom E

2.3. Cable

FutureCom D

17

FutureCom UD FutureCom UE

2.2. Certificates

Hardware

14

Flex Wire Cable Telephone / for Patch Cord ISDN Products

2.1. System Descriptions & Data

Industrial Cable

FutureCom F

Further Information

2

Introduction

Table of contents

Corning Cable Systems

13

FutureCom™ F System FutureCom F (2002) is Corning’s high-end system solution for symmetrical copper cabling. It satisfies all the requirements of the current ISO/IEC 11801 (2002) and EN 50173-1 (2003) standards for Class F links and Category 7 for the components. The

FutureCom F System is part of the Pretium™ Solutions family. Pretium Solutions is Corning Cable Systems’ high preformance

solution set for fiber and copper premises networks. Face Plate “DELTAprofil”, 80x80 mm WAXWSE-00001-C001 and S1200 Frame Set, for two S1200 Modules, Cat.7, inclined, CAXFSE-S0201-C001

SF/UTP flex/26, gray, 1xS1200/2 and 1xRJ45 connector, 2 pairs, for 10/100Base-T CCAFGD-D1024-A030-C1

FutureCom S/FTP 1200/22 CCXFCB-L0047-C001-L7

S1200 Module, 1xS1200, shielded, Cat. 7 CAXFSM-00100-C001

S1200 19“ Patch Panel, for max. 24 S1200 Modules, with integrated cable strain relief, 1 U, front panel of high-grade steel CAXFSV-02400-C001

S/FTP flex/26, rot, 1xS1200/4 and 1xRJ45- connector, 4 pairs, for 10/100/1000 Base-T CCAFGB-G5021-A020-C0

SF/UTP flex/26, gray, Cat.7, 2xS1200/2 connectors, 2 pairs CCAFGB-G1026-A020-C1

The highest level of system performance up to 10GBase-T for

The FutureCom F system offers technical transmission

The resulting performance and future security guaranty the

addition, it enables the optimal utilization of cabling

FutureCom F cabling conforms with the standards and is

The performance of the FutureCom F cabling system has

the complete link is achieved through the utilization of

high-quality Category 7 cables, connectors and patch cords. maximum level of investment protection for cabling.

outstandingly well suited for all recognized standardized

voice and data transmission procedures. This applies to analog voice transmission, ISDN, Token Ring, Ethernet (10-BaseT), Fast Ethernet (100Base-TX), Gigabit Ethernet, 10 Gigabit Ethernet, 100Base-VG and ATM.

14

possibilities similar to those of optical cabling systems and

permits multimedia applications, such as TV transmission. In

through the use of 2-pair patch cords (cable sharing).

been certified by an independent testing body (see certificate). Of course, all EMC values standardized in Europe are observed.

Corning Cable Systems

ACR in dB (typ. FutureCom F values) Min. ELFEXT in dB*

ELFEXT in dB (typ. FutureCom F values) Min. return loss in dB*

Return loss in dB (typ. FutureCom F values) * According to ISO/IEC 11801 (2002)

61.0

5.3 –

102.1 93.7 65.0



7.5 –

88.5 –

103.0 95.0 91.0 19.0 21.0



21.0 –



21.0 –

13.4 –

75.6 –

100 20.8 17.1

155.5 250 33.8 – 21.4

62.9 – 42.1

21.0 –

56.9 23.1

68.9 60.6 50.5 –

44.4 –

83.0 79.0 74.0 –

27.5

12.0

21.0

21.0 –

37.8

600 54.6 43.5 51.2

19.0

52.3

1000 1200 – – 57.6

68.0 60.0 58.0 24.5

–3.4 31.3

68.0 54.0 8.0

850 –

8.0

16.0



7.7 –

45.0 –

15.0 –



0.4 –

41.0 –

14.0 –

69.2 53.0 – – –

30.0 –

10.0 –

FutureCom D

The system values cited only apply to the use of original FutureCom F products. Derived values, such as PSACR, PSNEXT, PSELFEXT, are in observance of the standard values, but are not shown.

FutureCom F

Min. ACR in dB*

65.0

62.5 –

FutureCom 10TEN

104.0 99.0 96.0 89.0 86.0 82.0 78.0

Min. NEXT in dB*

1.9

20 –

FutureCom E

NEXT in dB (typ. FutureCom F values)

Attenuation in dB (typ. FutureCom™ F values)

10 –

Attenuation and

Near-end Crosstalk (NEXT)

NEXT in dB (typ. FutureCom F values) min. NEXT in dB According to standard

max. Attenuation in dB According to standard

Attenuation in dB (typ. FutureCom F values)

Further Information

Special Cable

Industrial Cable

Frequency in MHz

FutureCom UD FutureCom UE

Max. attenuation in dB*

1 4.0

Hardware

Frequency in MHz

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Electrical Characteristics (at 20°C)

Introduction

FutureCom™ F System Data for Channel Class F (2002)

Corning Cable Systems

15

FutureCom™ F System Data for Channel Class F (2002) Far-end Crosstalk Relating to the Far End (ELFEXT)

ELFEXT in dB (typ. FutureCom™ F values)

Min. ELFEXT in dB According to standard

Frequency in MHz Return Loss

Return loss in dB

(typ. FutureCom F values)

min. Return loss in dB According to standard

Frequency in MHz

Test Setup

FutureCom F F/STP flex/26 Test Adapter Cable, 2 m S1200 Module

90 m FutureCom F/STP 1200/22

S1200 Patch Panel 19“

FutureCom F F/STP flex/26 Test Adapter Cable, 2 m

16

Nominal intrinsic impedance

100 V

Max. DC loop resistance (according to standard)

40 V

Max. delay (according to standard)

0.05 µs

DC loop resistance

(typ. FutureCom F values)

Max. delay (according to standard)

Corning Cable Systems

15 V

, 0.02 µs

Further Information

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

FutureCom 10TEN

FutureCom F

Introduction

FutureCom™ F Certificates

Corning Cable Systems

17

FutureCom™ F Cat.7 + Cables S/FTP 1500/22 and S/FTP 1200/22

Braided shield

Halogen-free sheath, flame retardant Twisted pair

Foil shielding (PiMF) 4 shielded pairs

PE foam-skin insulation Copper conductor AWG 22

Application

The FutureCom™ S/FTP 1500/22 and S/FTP 1200/22 cables are designed for applications up to 1500/1200 MHz. Their

transmission characteristics significantly exceed the requirements defined by today’s Category 7 specifications

(EN50288).

FutureCom cables are low-skew products, i.e. the skew

between the individual pairs is very low. This is increasingly

required for applications above 1 Gigabit Ethernet. The possibility of using the cable up to the GHz area enables the

highest possible transmission rates for multimedia applications such as TV transmission, in future-proof networks. Each pair is individually foil shielded (FTP). The stranded

pairs (PiMF) are also sheathed with a braid shield (S/FTP),

which guarantees outstanding shielding characteristics. The

Mechanical Characteristics Conductor insulation

cable satisfies Class B interference radiation standards

(EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks.

Halogen-free

Foam-skin material

Outer jacket

Halogen-free,

Temperature range (installation)

0 to +50°C

Area/range of application

Operating temperature Min. bending radius

for one-time bending

Min. bending radius during installation

Copper conductor

18

flame retardant

Dry and damp rooms

-20 to +60°C

>_ 45 mm (for 2x (4x2...) over flat side)

>_ 65 mm (for 2x (4x2...) over flat side) AWG 22

Features

Specified up to 1500 MHz / 1200 MHz

Outstanding electrical characteristics Each pair is shielded (PiMF) Full copper braid shield Streamlined design Lightweight

Low skew between the pairs Halogen-free (LSZH)

Fire retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034

Corning Cable Systems

FutureCom™ F Cat.7 + Cables S/FTP 1500/22 and S/FTP 1200/22 Introduction

>5000 MV x km

125 V +/– 20 %

>46 dB at 64 kHz

Propagation velocity

0.77 x c for S/FTP 1200

FutureCom 10TEN

<2 m V/m at 10 MHz

Surface transfer impedance

>40 dB at 1 MHz

Unbalance to ground dB/BZL = 100 m

>20 dB at 100 MHz

Unbalance to ground dB/BZL = 100 m

FutureCom E

0.76 x c for S/FTP 1500

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

4.2 ns/m

6 ns/100 m

Delay skew

Electrical Characteristics (at 20°C) for S/FTP 1500/22

Frequency in MHz

1

10

16

31.25

62.5

100

300

600

NEXT in dB at 100 m *

80.0

80.0

80.0

80.0

75.1

72.4

65.3

60.8

Attenuation in dB/100m * Typical values dB/100m

Typical values in dB at 100 m PSNEXT in dB at 100 m *

Typical values in dB at 100m ELFEXT in dB at 100 m *

Typical values in dB at 100m PSELFEXT in dB at 100 m *

Typical values in dB at 100m ACR in dB

2.0 1.7

5.7

5.3

7.2

6.8

10.1 9.7

77.0

102.0 80.0

96.0 77.0

93.0

103.3

77.0

102.0 74.0

96.0 71.0

93.0 99.7

Frequency in MHz

1

10

NEXT in dB at 100 m *

80.0

80.0

Typical values dB/100m

13.8

77.0

102.0 69.9

96.0 66.9 93.0 98.2

77.0

102.0 64.1

93.0 61.1

90.0 95.3

2.0

5.7

16

7.2

20

8.1

72.5

102.0 58.1

88.0 55.1

85.0 91.2

PSELFEXT in dB at 100 m *

77.0

ELFEXT in dB at 100 m *

Typical values in dB at 100m Typical values in dB at 100m ACR in dB

1.6

4.9

6.4

80.0

74.0

69.9

68.0

64.1

94.0

94.0

94.0

94.0

91.0

96.0

103.3

96.0 71.0

100.1

96.0 93.0 66.9 65.0 98.6

98.0

69.4

102.0 54.0

82.0 51.0

79.0 87.5

10.1

Typical values in dB at 100m

PSNEXT in dB at 100 m *

17.5

31.25

7.0 9.0 80.0 80.0 80.0 >105.0 >105.0 >105.0 >105.0 >105.0 77.0 77.0 77.0 77.0 77.0 103.0 103.0 103.0 103.0 103.0

Typical values in dB at 100 m

18.5

33.3

30.8

>105.0 >105.0 >105.0 >105.0 >105.0 >105.0 103.0

Electrical Characteristics (at 20°C) for S/FTP 1200/22

Attenuation in dB/100m *

14.5

93.0 61.1

96.0

62.3

48.9

44.0 95.0 57.8

100.0 92.0 44.5

68.0 41.5 5.0

72.2

38.4 55.0

35.4

52.0 51.0

1000 57.8 –

85.0 –

82.0 37.0 –

34.0 –

27.2

62.5

100

300

600

75.1

72.4

65.3

60.8

14.5

12.8

18.5

16.5

33.3

28.9

>105.0 >105.0 102.0 72.5

103.0 58.1

88.0 55.1

86.0 92.2

69.4

103.0 54.0

82.0 51.0

80.0 88.5

62.3

48.9 47.1

95.0 57.8

100.0 93.0 44.5

70.0 41.5

68.0 73.1

38.4 55.0

35.4 53.0 53.3

1200 63.6 –

80.0 –

77.0 31.0 –

28.0 –

16.4

1500 72.0 –

75.0 –

72.0

24.0 –

21.0 –

3.0

1000 1200 54.5 –

85.0 –

83.0

40.0 –

38.0 –

30.5

59.8 –

80.0 –

78.0 35.0 –

33.0 –

20.2

* Standard: Requirements for 100 m installed Category 7 cable for Class F cabling sections (complies with EN 50288-4-1 and IEC 61156-7)

Corning Cable Systems

FutureCom D

Unbalance to ground dB/BZL = 1000 m

100 V +/– 25 %

Impedance Zo at 251 - 600 MHz

FutureCom UD FutureCom UE

100 V +/– 18 %

Hardware

Impedance Zo at 101 - 250 MHz

FutureCom F

100 V +/– 15 %

Impedance Zo at 1 - 100 MHz

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Impedance Zo at 0.064 MHz

Industrial Cable

Insulation resistance

1%

19

Special Cable

Largest resistance margin

Further Information

Electrical Characteristics (at 20°C)

FutureCom™ F Cat.7 + Cables S/FTP 1500/22 and S/FTP 1200/22 Ordering Information Type designation

Max. Outer [ Weight Length Fire Load Halogen- Tensile Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number

S/FTP 1500/22 8P

7+

S/FTP 1500/22 4P

S/FTP 1200/22 4P

S/FTP 1200/22 8P

20

7+

4

0.67

Yes

179

7.7

7+

8

1.34

Yes

358

7.7x16.5 133

7+

8 4

1.34

0.67

Yes Yes

358 179

Corning Cable Systems

66

7.7x16.5 133 7.7

66

1000

CCXFCB-M0047-C001-L7

500

CCXFCB-L0087-C001-L6

500

1000

CCXFCB-M0087-C001-L6 CCXFCB-L0047-C001-L7

FutureCom™ F S1200 Modules and Connectors Introduction

Features

Category 7+ Module

Up to 1200 MHz bandwith per pair

Dust protection flap to prevent exposure to contaminants

FutureCom F

Wide range of installation options Few individual components

High-level component density

S1200 Adapter

Removing the module icon (black plastic clasp on the upper side of the S1200 Module) enables the S1200 module to be inserted into the module adapter. The S1200 adapter ex-

tends the application possibilities of the Cat. 7 module to

many components in the LANscape® product range, such as: Patch panels Frame sets

Hardware

Floor box solutions

FutureCom UD FutureCom UE

FutureCom D

Individual components of the S1200 Module

FutureCom E

FutureCom 10TEN

Individual shielding of the modules

Flex Wire Cable Telephone / for Patch Cord ISDN Products

S1200 Module with adapter for LANscape® interface

S1200 Connector Types

For the FutureCom™ F System, the following connector types are offered: S1200/4 shielded connector, 4-pair

Industrial Cable

(for solid or stranded conductors)

S1200/2 shielded connector, 2-pair S1200/1 shielded connector, 1-pair

S1200 Connector Types

Corning Cable Systems

21

Further Information

Special Cable

All patch cords modes can be created using these connectors.

FutureCom™ F Modules and Module Accessories Features

Bandwidths up to 1200 MHz per pair of wires Quick and easy to install

IDC connection (IDC = Insulation Displacement Contacts) Universal usage (direct or with adapter) in many LANscape® components

Negligible effect from interference through the individual shielding of the modules

Ordering Information Order Number

CAXFSM-00100-C001

Description

S1200 module, 1 x S1200, shielded, Cat. 7+, for installation in LANscape patch panels, outlets and floor box mounting plates

S1200 Module Adapter Order Number

CAXFSN-00110-C001

Blank Covers Order Number

CAXFSN-00101-C001

CAXFSN-00108-C001

22

Description

S1200 module adapter, for the installation

of the S1200 modules in LANscape patch panels, outlets and floor box mounting plates

Description

1 slot for installation in

FutureCom™ F S1200 patch panels,

outlets and floor box mounting plates

(S1200 direct assembly without module adapters) white, RAL 9010 black, RAL 9005

Corning Cable Systems

Units per Delivery 1/1

Units per Delivery 6/1

Units per Delivery

10/1

10/1

FutureCom™ F S1200 Connectors Introduction

Features

Bandwidths up to 1200 MHz per pair Quick and easy to install

IDC connection (IDC = Insulation Displacement Contacts)

FutureCom F

High density, i.e. for each module the following connector combinations can be used: – one 4-pair connector

FutureCom 10TEN

– two 2-pair connectors

– one 2-pair connector and two 1-pair connectors – four 1-pair connectors

Shielded connectors are designed for the use with S/FTP

FutureCom E

type cables

S1200/4 Connector, shielded, Cat. 7+,

Units per Delivery

CAXFSS-00100-C004

1200/4 Connector, shielded, Cat. 7+,

1/1

4-pair, for solid wire AWG 22 to 23,

Further Information

Special Cable

Industrial Cable

e.g. for consolidation point cabling

1/1

Hardware

4-pair, for flex wire cables AWG 26

FutureCom UD FutureCom UE

CAXFSS-00100-C001

Description

Order Number

Flex Wire Cable Telephone / for Patch Cord ISDN Products

S1200/4 Connector 4-pairs, shielded, Cat.7+

FutureCom D

Ordering Information

Corning Cable Systems

23

FutureCom™ F S1200 Connectors Ordering Information

S1200/2 Connector, 2-pair, shielded, Cat. 7+ Order Number

CAXFSS-00100-C002

Description

S1200/2 Connector, shielded, Cat.7+, 2-pair, for flex wire cable AWG 26

S1200/1 Connector, 1-pair, shielded, Cat. 7+ CAXFSS-00100-C003

24

S1200/1 Connector, shielded, Cat.7+, 1-pair, for flex wire cable AWG 26

Corning Cable Systems

Units per Delivery 1/1

1/1

FutureCom™ F Tools

Introduction

Features of the S1200 Assembly Tool Integrated knife for the removal of the jacket

Stripping option for the PiMF foils with a defined length

Management for arrangement or shaping of the individual

FutureCom F

pairs (PiMF)

CAXFSN-00000-C001

Description S1200 Tool,

for the assembly

of S1200 modules

Units per Delivery

FutureCom E

Order Number

1/1

FutureCom D

Ordering Information

FutureCom 10TEN

Defined section length of the wires

and S1200/4 or

1/1

CAXCSN-00000-C004

Copper Conducting Tape, 12.7 mm wide,

2/1

Further Information

roll length 16.5 m

Special Cable

the IDC contacts on FutureCom™ S1200 modules

Hardware

Comfort Parallel Pliers, for the termination of

Flex Wire Cable Telephone / for Patch Cord ISDN Products

CAXCSN-00000-C008

Industrial Cable

Parralel Pliers and Copper Conducting Tape

FutureCom UD FutureCom UE

S1200/2 connectors

Corning Cable Systems

25

FutureCom™ F Outlets and Outlet Accessories Features of the Frame Set

Direct installation of S1200 modules

Central plate dimensions of 50 x 50 mm and can be combined with “DELTAprofil” and “DELTAfläche” face plates,

as well as face plates from other manufacturers Designation window

Ordering Information Order Number

CAXFSE-S0201-C001

Description

S1200 Frame Set, inclined, for 2 FutureCom™ S1200 modules, including mounting frame and 50x50 mm central plate with designation window, threaded, white RAL 9010

Units per Delivery 1/1

Features of the Frame Sets

Installation of S1200 modules with module adapters

Central plate dimensions of 50 x 50 mm and can be combined with “DELTAprofil” and “DELTAfläche” face plates,

as well as face plates from other manufacturers Designation window Order Number

WAXWSE-V0201-C001 WAXWSE-V0202-C001

Description

Frame Set, inclined, projecting, for 2 S1200 modules with module adapters, including mounting frame and 50x 50 mm central plate with designation window and dust protection flaps white, RAL 9010 pearl white, RAL 1013

Labeling icons and designations labels can be found on page 131.

Brackets for raceway mounting can be found on page 134.

26

Corning Cable Systems

Units per Delivery

1/1 1/1

FutureCom™ F Outlets and Outlet Accessories Introduction

Features of the Universal Integration Housing Direct assembly of S1200 modules

WAXWSE-V0201-C002

Description

Universal Housing, inclined, projecting,

for face plate (147x87 mm and 87x87 mm)

for the direct integration of 2 S1200 modules,

FutureCom 10TEN

Order Number

Units per Delivery 1/1

FutureCom E

Ordering Information

FutureCom F

Surface mount housing suitable for the face plates; see page 136.

Face Plate, 87x87 mm, for one housing,

including two metric screws and

FutureCom UD FutureCom UE

WAXWSE-00001-C005

FutureCom D

central partition provided, white, RAL 9010

1/1

two withworth screws,

for frame assembly in installation outlets,

white, RAL 9010

Hardware

(Suitable Surface Mount Housing Face Plate, 87x147 mm,

1/1

for two housings,

including two metric screws and two withworth screws,

for frame assembly in installation outlets, white, RAL 9010

(Suitable Surface Mount Housing

Special Cable

Industrial Cable

WAXWSE-00001-C006; see page 136)

Further Information

WAXWSE-00001-C007

Flex Wire Cable Telephone / for Patch Cord ISDN Products

WAXWSE-00001-C004; see page 136)

Corning Cable Systems

27

FutureCom™ F Outlets and Outlet Accessories Ordering Information Order Number

Units per Delivery

Description

Frame Set, inclined, for 3 S1200 modules with module adapters,

including mounting frame and triple housing with designation window WAXWSE-V0301-C001

WAXWSE-V0302-C001

and dust protection flaps,

also as 80x80 mm face plate white, RAL 9010

1/1

pearl white, RAL 1013

1/1

Frame Set, inclined, for 6 S1200 modules with module adapters,

including mounting frame and two triple housings

with designation window and WAXWSE-V0601-C001

WAXWSE-V0602-C001

Installation Option

dust protection flaps,

also as a 151x80 mm face plate white, RAL 9010

1/1

pearl white, RAL 1013

1/1

Frame Set, inclined, for 6 S1200 modules with module

adapters, including mounting frame and two triple housings with designation window and dust protection flaps, as well as 151 x 80 mm face plate, white, RAL 9010: WAXWSE-V0601-C001

equipped with four S1200 modules with module adapters CAXFSM-00100-C001 + CAXFSN-00110-C001 one triple MT-RJ OM3 module LAXLSM-00212-C002

two black labeling icons WAXWSE-00008-C001

two blue labeling icons Frame Set, inclined, projecting, for 6 modules, integrated into a raceway

WAXWSE-00004-C001

two green labeling icons WAXWSE-00006-C001

one black SF/UTP flex/26 Cat. 5 Patch Cord CCAFGD-D6024-A020-C1

and one blue S/FTP flex/26 Cat. 6 Patch Cord CCAFGB-G2021-A030-C0

28

Corning Cable Systems

FutureCom™ F Floor Box Solutions Introduction

Features

Specially designed for the direct integration of S1200 modules

Stable metal construction, no additional installation

FutureCom F

trough required

Integrated cable strain relief that can be mounted in various positions

FutureCom 10TEN

No screwing required

Integrated grounding bolt

Order Number

CAXFSU-00600-C001

Description

Mounting Panel for Ackermann Floor Boxes GES 2, GES 4, GES 4/10, GESR 4, GES 6,

GES 6/10, GESR 7/10 (outer) or GES 8/10,

Units per Delivery

FutureCom D

Ordering Information

FutureCom E

Designation window with title strips

1/1

FutureCom UD FutureCom UE

for the installation

of 6 FutureCom™ F S1200 modules,

with integrated cable strain relief and six cable ties,

designation window, black

Mounting Panel for Ackermann Floor Boxes GESR 7/10 (center), GES 9 or GESR 9, for

the installation

1/1

Hardware

CAXFSU-00900-C001

Flex Wire Cable Telephone / for Patch Cord ISDN Products

of 9 FutureCom F S1200 modules,

with integrated cable strain relief and nine cable ties,

designation window, black

1/1

VanGeel Floor Box IK-1 (long), for the installation

Industrial Cable

Mounting Panel for

of 9 FutureCom F S1200 modules,

Special Cable

with integrated cable strain relief and nine cable ties,

designation window, black

Further Information

CAXFSU-00900-C005

Corning Cable Systems

29

FutureCom™ F Floor Box Solutions Ordering Information Order Number

CAXFSU-00900-C002

Description

Mounting Panel for Kleinhuis Floor Box GR. II and GR. III (outside only), for the installation

of 9 FutureCom™ F S1200 modules,

with integrated cable strain relief and nine cable ties,

designation window, black

Installation Option

Mounting Panel for Kleinhuis Floor Boxes GR. II and GR. III (only left or right position): CAXFSU-00900-C002

The three 3-port mounting places are configured as follows: equipped with two S1200 modules, CAXFSM-00100-C001

one blank cover, white, CAXFSN-00101-C001 and two gray 2-pair

SF/UTP flex/26 10/100BaseT Patch Cords CCAFGD-D1024-A030-C1

equipped with two S1200 modules, CAXFSM-00100-C001

one blank cover, black, CAXFSN-00108-C001

equipped with three S1200 modules, CAXFSM-00100-C001

and one blue S/FTP flex/26 Cat. 6 Patch Cords CCAFGB-G2021-A030-C0

For applications requiring fiber optic and copper solutions, the S1200 module can be integrated into the various floor

box mounting panels from the LANscape® product range using an adapter (see pages 144-151).

30

Corning Cable Systems

Units per Delivery 1/1

FutureCom™ F S1200 Patch Panels Introduction

Features

Specially designed for the direct integration of S1200 modules

Integrated shielded transitional spring

Order Number

CAXFSV-02400-C001

Description

S1200 Patch Panel 19“, shielded, Cat. 7+,

including 24 FutureCom™ F S1200 modules,

with integrated cable strain relief and shielded

Units per Delivery

FutureCom E

Ordering Information

FutureCom 10TEN

FutureCom F

Patch panel accessories, see page 156

1/1

S1200 Patch Panel 19“,

for max. 24 FutureCom F S1200 modules,

with integrated cable strain relief and shielded

FutureCom UD FutureCom UE

CAXFSV-02400-C002

FutureCom D

transitional spring, 1 U, high-grade steel

1/1

transitional spring, 1 U,

for max. 12 FutureCom F S1200 modules,

with integrated cable strain relief and shielded

1/1

Flex Wire Cable Telephone / for Patch Cord ISDN Products

S1200 Patch Panel 10“,

transitional spring, 1 U,

Special Cable

Industrial Cable

high-grade steel front panel

Further Information

CAXFSV-01200-C001

Hardware

high-grade steel

Corning Cable Systems

31

Consolidation Point Housings for S1200 Modules Features

Full metal housing for the installation of up to 12 FutureCom™ S1200 modules

Standard-compatible according to ISO/IEC 11801 (2002) and EN 50173-1 (2003)

Easy installation for a distribution or consolidation point Consolidation point housing is suitable for ceiling, wall, false floor or desk assembly

Individual strain relief for the incoming and outgoing cable sections

Dust-proof feedthrough for incoming cable

Easy plug-in of consolidation point cable (dust protection and mechanical protection)

Housing base electrically conductive for optimal shielding transition or grounding Installation height of 60 mm

Housing is fastened using special non-detachable screws Black sheet steel housing top, RAL 9005

Ordering Information Order Number

Description

WAXWSW-00008-C014 Consolidation Point Housing for max. 12 FutureCom F S1200 modules,

with strain relief for incoming data cables, patch cord strain relief and dust protection flap for floor, wall and ceiling installation, 60 x 263 x 320 mm (HxWxD)

32

Corning Cable Systems

Units per Delivery 1/1

FutureCom™ F Cat. 7 Patch Cords S1200 to S1200 Introduction

Description

FutureCom F Category 7 patch cords are available in two or

four pair versions with foil and full braided shielding (S/FTP). They are pre-terminated with shielded S1200 connectors on

FutureCom F

both ends and are available in various lengths. The patch

cords meet all the transmision property requirements for

FutureCom 10TEN

Channel F (2002).

Features

FutureCom E

S/FTP flex cable, specified up to 600 MHz

S1200/4 connector pair fully configured and application-neutral

FutureCom D

S1200/4 connector pair for up to 10GBase-T applications S1200/2 connector pair fully configured on both sides Minimum surface transfer impedance (<10 mV/m at 10 MHz)

010 015 020 030 040 050 060 100

= = = = = = = =

1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 10 meters

1

1

- C1

Select length. 010 015 020 030 040 050 060 100

= = = = = = = =

1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 10 meters

Hardware

CCAFGB - G1026 - A

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Select length.

- C0

Industrial Cable

1

1

Special Cable

CCAFGB - G1022 - A

Further Information

Ordering Information

FutureCom UD FutureCom UE

Outstanding transmission characteristics

Corning Cable Systems

33

FutureCom™ F Cat. 6 Patch Cords S1200/4 to RJ45 Description

Application-neutral, Category 6 S/FTP patch cords with four pairs are pre-terminated with S1200/4 and RJ45 connectors. The patch cords meet all the transmision property

requirements for Channel E (2002) and Cat. 6 (2002).

Features

S/FTP flex cable, specified up to 600 MHz

Pre-terminated with S1200/4 on one end and RJ45 on the other end

Minimum surface transfer impedance (<10 mV/m at 10 MHz)

Outstanding transmission characteristics 4-pair, AWG 26, Cat. 6 (2002)

Ordering Information

CCAFGB - G 1

Select color.

2

Select length.

1 2 3 4 5 6

= = = = = =

gray blue yellow green red black

010 015 020 030 040 050 060 080 100 150

= = = = = = = = = =

1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 8 meters 10 meters 15 meters

34

1

021 - A

2

- C0

Corning Cable Systems

FutureCom™ F Cat. 5 Patch Cords S1200/4 to RJ45 Introduction

Description

Application-neutral, Category 5 SF/UTP patch cords with four pairs are pre-terminated with S1200/4 and RJ45 connectors. The patch cords meet all the transmision property require-

FutureCom F

ments for Channel D (2002) and Cat. 5 (2002).

FutureCom 10TEN

Features

SF/UTP flex cable, specified up to 300 MHz

FutureCom E

Pre-terminated with S1200/4 and RJ45 connectors Minimum surface transfer impedance (<10 mV/m at 10 MHz)

FutureCom D

Outstanding transmission characteristics

Select length.

= = = = = =

gray blue yellow green red black

010 015 020 030 040 050 060 080 100

= = = = = = = = =

1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 8 meters 10 meters

Hardware

2

1 2 3 4 5 6

- C0

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Select color.

2

Industrial Cable

1

1

021 - A

Special Cable

CCAFGF - D

Further Information

Ordering Information

FutureCom UD FutureCom UE

4 Pair, AWG 26, Cat. 5 (2002)

Corning Cable Systems

35

FutureCom™ F Cat. 5 Patch Cords S1200/2 to RJ45 Description

Category 5 SF/UTP patch cords with two pairs are

pre-terminated with S1200/2 and RJ45 connectors. The patch cords meet all the transmision property requirements for Channel D (2002) and Cat. 5 (2002).

Features

SF/UTP flex cable, specified up to 300 MHz

Pre-terminated with S1200/2 and RJ45 connectors Minimum surface transfer impedance (<10 mV/m at 10 MHz)

Outstanding transmission characteristics 2 Pair, AWG 26, Cat. 5 (2002)

Ordering Information

For 10/100 Base-T Applications (Pins 1.2 - 3.6)

CCAFGD - D 1

Select color.

2

Select length.

10 60

010 015 020 030 040 050 060 080 100 150

36

= =

= = = = = = = = = =

1

24 - A

gray black

1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 8 meters (gray only) 10 meters (gray only) 15 meters (gray only)

2

- C1

For TR/ISDN and Analog Applications (Pins 4.5 - 3.6)

CCAFGD - D 1

2

Select color.

1

24 - A

11 = gray 41 = green

Select length. 010 015 020 030 040 050 060 080 100 150

Corning Cable Systems

= = = = = = = = = =

1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 8 meters (gray only) 10 meters (gray only) 15 meters (gray only)

2

- C1

FutureCom™ F U/UTP Flex Patch Cords Introduction

Description

FutureCom™ F U/UTP flex FRNC patch cords are pre-

terminated with S1200/1 or S1200/2 and RJ45 or RJ11/12

FutureCom F

connectors for service specific applications.

FutureCom 10TEN

Features

U/UTP flex cable, specified up to 100 MHz

Pre-terminated with S1200/1 or S1200/2 connectors

FutureCom E

Pre-terminated with RJ11/12 or RJ45 connectors Minimum surface transfer impedance (<10 mV/m at 10 MHz)

1

Select application.

2

Select connector types.

1 0

= =

2 Pair, TR/ISDN and analog (4.5 - 3.6) 1 Pair, Telephone / Neutral

24 25 27 28 34

= = = = =

S1200/2 to RJ45 S1200/2 to RJ11 S1200/1 to RJ45 (Telephone) S1200/1 to RJ11 (Telephone) S1200/1 to S1200/1 (Neutral)

010 015 020 030 040 050 060 080 100

= = = = = = = = =

1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 8 meters 10 meters

3

- C0

Special Cable

Select length.

Further Information

3

2

-A

Hardware

1

Flex Wire Cable Telephone / for Patch Cord ISDN Products

CCAFFE - A6

Industrial Cable

Ordering Information

FutureCom UD FutureCom UE

FutureCom D

FRNC cable, unshielded

Corning Cable Systems

37

FutureCom™ F TV Connecting Cable Features

S1200/1 connector and balun (connector or jack) for the conversion of Cat.7+ cabling into coaxial cabling incl. impedance adjustment

Very low surface transfer impedance (<10 mV/m at 10 MHz)

Specifications Insertion Attenuation Back-to-back Return loss

(75 V

(100 V

Measured at the 75 V end

100 V)

< 2 dB

75 V)

< 3.5 dB

The 100 V end is terminated with a resistor of 100 V. Surface transfer impedance Rk [mV]

Ordering Information Order Number

Description

< 19 dB < 12 dB

< 20 mV

Length

CCAFGB-I4054-A030-C0

FutureCom™ TV/CATV Patch Cord,

3m*

CCAFGB-I4055-A030-C0

FutureCom TV/CATV Patch Cord,

3m*

* Other lengths upon request

38

1 x S1200/1 and 1xTV connector (IEC60169-2),

FRNC sheath, green

1 x S1200/1 connector and 1 xTV jack (IEC60169-2), FRNC sheath, green

Corning Cable Systems

Frequency Range 5...300 MHz

300...450 MHz 5...300 MHz

300...450 MHz

10 MHz

FutureCom™ F Plug & Play™ Solution Introduction

Application

The S1200 Solution Packages are factory pre-terminated cables. They are offered with FutureCom™ S/FTP 1200/22 cables, and enable Plug & Play™ installation, significantly

reducing installation time. The assemblies are 100% factory tested, preventing installation faults on-site.

CCAFCB-M2042-A250-C0

CCAFCB-M2042-A300-C0 CCAFCB-M2042-A350-C0

CCAFCB-M2042-A400-C0 CCAFCB-M2042-A450-C0

CCAFCB-M2042-A500-C0 CCAFCB-M2042-A550-C0

CCAFCB-M2042-A600-C0 CCAFCB-M2042-A650-C0

CCAFCB-M2042-A700-C0 CCAFCB-M2042-A750-C0

CCAFCB-M2042-A800-C0 CCAFCB-M2042-A850-C0

CCAFCB-M2042-A900-C0 CCAFCB-M2042-A950-C0

S1200 Solution Package S/STP1200/22 - 10

10 m

S1200 Solution Package S/STP1200/22 - 25

25 m

S1200 Solution Package S/STP1200/22 - 15

S1200 Solution Package S/STP1200/22 - 20

S1200 Solution Package S/STP1200/22 - 45

45 m

S1200 Solution Package S/STP1200/22 - 40 S1200 Solution Package S/STP1200/22 - 50 S1200 Solution Package S/STP1200/22 - 55

S1200 Solution Package S/STP1200/22 - 60 S1200 Solution Package S/STP1200/22 - 65

35 m

40 m 50 m 55 m

60 m 65 m

S1200 Solution Package S/STP1200/22 - 70

70 m

S1200 Solution Package S/STP1200/22 - 85

85 m

S1200 Solution Package S/STP1200/22 - 75

S1200 Solution Package S/STP1200/22 - 80

S1200 Solution Package S/STP1200/22 - 90 S1200 Solution Package S/STP1200/22 - 95

Description

CP Solution Package S/FTP1200/22, 4 pairs, application-neutral, FRNC jacket,

FutureCom 10TEN

20 m

30 m

S1200 Consolidation Point Solution Packages Order Number

15 m

S1200 Solution Package S/STP1200/22 - 30 S1200 Solution Package S/STP1200/22 - 35

FutureCom E

with 2 S1200 Modules

FutureCom D

CCAFCB-M2042-A200-C0

FRNC jacket, pre-terminated

FutureCom UD FutureCom UE

CCAFCB-M2042-A150-C0

data cable, 4 pairs, application neutral,

Length

Hardware

CCAFCB-M2042-A100-C0

Description

Solution Package with S/FTP 1200/22

75 m

80 m

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Order Number

90 m 95 m

Length

Industrial Cable

S1200 Solution Packages

FutureCom F

Ordering Information

CCAFCB-M2058-A100-C0 CCAFCB-M2058-A150-C0

CCAFCB-M2058-A200-C0

for consolidation points

CP Solution Package S/STP1200/22 -5

CP Solution Package S/STP1200/22 -10 CP Solution Package S/STP1200/22 -15

CP Solution Package S/STP1200/22 -20

5m

10 m

15 m

Further Information

CCAFCB-M2058-A050-C0

connector and one S250 module

Special Cable

pre-terminated with one S1200/4

20 m

Corning Cable Systems

39

FutureCom™ F Test Adapter Cables Applications

For acceptance tests, special Test Adapter Cables are needed for the Fluke DSP 4x00 and Microtest OMNIScanner/-

OMNIScanner 2 testers in accordance with Class F (2002).

A pair of these test adapter cables is always required to perform the test.

Ordering Information CCAFGB-G20ME-A020-C0

Description

S1200 Test Adapter Cable, 2 m,

Units per Delivery

CCAFGB-G20MM-A020-C0

S1200 Test Adapter Cable, 2 m, for Microtest

2/1

Order Number

for Fluke DSP 4x00 (per pair)

OMNIScanner/OMNIScanner 2 (per pair)

If you require test adapter cables for other testing equipment (e.g. LANTEK 7), please contact the relevant manufacturer directly.

40

Corning Cable Systems

2/1

3.3. Cable

46

3.4. Connecting Hardware

3.4.1. S10TEN Module Overview

47

3.4.2. S10TEN Module

48

3.5.1. S10TEN Outlets

49

3.5. Hardware

3.5.2. S10TEN Patch Panels

49

3.6.1. 10GBase-T Patch Cords

50

3.6. Patch Cords

3.6.2. Consolidation Point Patch Cords

51

3.7. Plug & Play™

52

54

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

3.8. Test Cable

FutureCom F

45

FutureCom 10TEN

3.2. Certificate

FutureCom E

42

FutureCom D

3.1. System Descriptions & Data

FutureCom UD FutureCom UE

FutureCom™ 10TEN System

Further Information

3

Introduction

Table of contents

Corning Cable Systems

41

FutureCom™ 10 System TEN

Corning Cable Systems’ FutureCom™ 10 System has been especially developed to support 10 Gigabit Ethernet (10GBase-T) TEN

over 100 meters. FutureCom 10 is the latest addition to Pretium™ Solutions, Corning Cable Systems’ high-performance TEN

fiber and copper solutions for premises networks, and is fully compliant with the IEEE 802.3an (Draft 2.0) standard for

10 Gigabit Ethernet transmission. The current FutureCom 10 is especially designed for 10 Gigabit applications in riser and TEN

horizontal environments, avoiding alien near-end and far-end cross talk (ANEXT, AFEXT), in order to warrant the higher performance of cabling through immunity.

Face Plate “DELTAprofil”, 80x80 mm WAXWSE-00001-C001 and S10TEN outlet, 2xRJ45, 10GBase-T, inclined CAXTSD-S0201-C001

S/FTP flex/26, gray, 2xRJ45 connectors, 4 pairs, for up to 10 GBase-T CCATGD-G1002-A020-C0

FutureCom S/FTP900/23 CCXEDB-I0047-C001-L7

S10TEN Patch Panel 19“, for max. 24 S10TEN modules, with integrated cable strain relief, 1 U, front panel of high-grade steel WAXTSV-02400-C001

S10 Module, 1 x RJ45,shielded, 10GBase-T CAXTSM-00112-C001 TEN

S/FTP flex/26, gray, 2xRJ45- connectors, 4 pairs, for up to 10GBase-T CCATGB-G1002-A020-C0

A very high level of system performance is achieved for the

It is suitable for all recognized standardized voice and data

maximum future security and reliability.

The performance of the FutureCom 10TEN cabling system has

link through the use of high-quality 10GBase-T connection technology. The quality of the components guarantees

Using all eight contacts in the RJ45 Connector as well as in

the RJ45 Module, the cabling can be used universally and is application-independent.

42

transmission applications up to 10GBase-T.

been certified by an independent testing body (see certificate). Of course, all standardized EMC threshold values in Europe are observed.

Corning Cable Systems

FutureCom™ 10 System Data for Channel 10GBase-T

61.0

Min. ACR in dB according to standard *

88.1

ACR in dB (typ. FutureCom 10 values) TEN

63.3

Min. ELFEXT in dB* according to standard *

80.4

ELFEXT in dB (typ. FutureCom 10 values) TEN

19.0

Min. return loss in dB according to standard *

33.9

Return loss in dB (typ. FutureCom 10TEN values) * According to IEEE 802.3 an (draft 2.0).

85.3 78.5 –

61.9 –

32.7 –

8.0

75.0 –

66.6 –

56.4 –

30.7 –

63.6

57.9

14.3 –

49.5 –

52.9 –

32.4 –

18.1

39.9 18.2

40.1 23.3 51.8

12.0 32.1

155.5 200 – –

250 500 35.9 53.4

53.3

47.9 37.6

22.7 –

31.3 –

44.3 –

31.3 –

25.7

50.7 –

25.8 –

41.0 –

30.3 –

28.8 41.9 33.1

22.0

– 2.8 – 31.4 20.2 -2.0 15.3

38.1 7.2

9.3

31.3 6.0

26.5 22.1

The system values cited only apply to the use of original FutureCom 10TEN products. Derived values, such as PSACR, PSNEXT, PSELFEXT, are in observance of the standard values, but are not shown.

Attenuation and

Near-end Crosstalk (NEXT)

NEXT in dB (typ. FutureCom 10TEN values) min. NEXT in dB According to Standard

max. Attenuation in dB According to Standard

Attenuation in dB (typ. FutureCom 10TEN values)

Further Information

Special Cable

Industrial Cable

Frequency in MHz

FutureCom F

TEN



100 21.7

FutureCom 10TEN

Min. NEXT in dB according to standard *

5.6

62.5 –

FutureCom E

89.4

65.0

20 –

FutureCom D

NEXT in dB (typ. FutureCom 10 values)

2.0

Attenuation in dB (typ. FutureCom 10TEN values)

10 –

FutureCom UD FutureCom UE

Max. attenuation in dB according to standard *

1 4.0

Hardware

Frequency in MHz

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Electrical Characteristics (at 20°C)

Introduction

TEN

Corning Cable Systems

43

FutureCom™ 10 System Data for Channel 10GBase-T TEN

Far-end Crosstalk Relating to the Far End (ELFEXT)

ELFEXT in dB (typ. FutureCom 10TEN values)

Min. ELFEXT in dB According to standard

Frequency in MHz

Return Loss

Return loss in dB

(typ. FutureCom 10TEN values)

min. Return loss in dB According to standard

Frequency in MHz

Test Setup

FutureCom 10TEN Test Cord, 2 m

S10

TEN

Module

FutureCom F/STP 900/23 S10TEN Patch Panel 19“

FutureCom 10TEN Test Cord, 2 m

44

Nominal intrinsic impedance

Max. DC loop resistance (according to standard) DC loop resistance

(typ. FutureCom 10TEN values)

Max. delay (according to standard)

Max. delay (typ. FutureCom 10TEN values)

Corning Cable Systems

100 V 40 V 18 V

0.05 µs

, 0.02 µs

Further Information

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

FutureCom 10TEN

FutureCom F

Introduction

FutureCom™ 10 Certificate TEN

Corning Cable Systems

45

FutureCom™ 10 10GBase-T Cables TEN

Braided shield

Halogen-free jacket, flame retardant Twisted pair

Foil shielding (PiMF) 4 shielded pairs

PE foam-skin insulation

Features

Copper conductor AWG 23 - AWG 22

Application

The cables for the FutureCom™ S10TEN System are designed

for applications up to 1500 MHz (S/FTP 600 up to S/FTP 1500*). Their transmission characteristics significantly exceed the requirements defined by today’s Category 7 specifications

(EN50288-4-1).

FutureCom cables are low-skew products, i.e. the skew

between the individual pairs is very low. This is increasingly required for applications running 10 Gigabit Ethernet. The

possibility of using the cable up to the GHz area enables the highest possible transmission rates for multimedia applications, such as TV transmission, in future-proof networks. Each pair is individually foil shielded (FTP). The stranded

pairs (PiMF) are also sheathed with a braid shield (S/FTP),

Specified up to 1500 MHz

which guarantees outstanding shielding characteristics. The

Outstanding electrical characteristics

cable satisfies Class B interference radiation standards

Each pair is shielded (PiMF)

(EN 55022), as well as immunity (EN 55024), which enables

Full copper braid shield

the realization of CE-compatible networks.

Streamlined design Lightweight

Low signal skew between the pairs

Halogen-free (LSZH)

Fire retardant according to IEC 60332-3, Category C

Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034

* For S/FTP 600 and 900 cable please see pages 61-63. For S/FTP 1500 and 1200 cable please see pages 18-20.

46

Corning Cable Systems

FutureCom™ S10 Module Overview

TEN

Introduction

Features

Fully compatible with all modular LANscape® systemes

Wide range of installation options Few individual components

FutureCom F

High-level component density Individual shielding Halogen-free

Individual Components of the S10TEN Module

FutureCom D

FutureCom™ S10TEN Technology

FutureCom E

FutureCom 10TEN

Fire class UL94V-0

Optimized construction with printed circuit board for Proven IDC technology for wires with AWG 24 to AWG 22 Module reusable several times

Disassembled S10TEN Module

Application

Wire management using TIA/EIA 568 A/B coding

Transparent wire management allows direct control of correct wiring

Installation in pairs (no untwisting of pairs is necessary)

Industrial Cable

Rapid assembly times

Flex Wire Cable Telephone / for Patch Cord ISDN Products

More than 1500 connector cycles are possible

Hardware

FutureCom UD FutureCom UE

bandwidths of more than 500 MHz

Easy handling

S10TEN Wire Management, without/with cable

Corning Cable Systems

47

Further Information

Special Cable

Compatible with all FutureCom S/FTP cables

FutureCom™ 10 S10 Module TEN

TEN

Features

Easy and quick to install, no special tools required

IDC connection (IDC = Insulation Displacement Contacts) High-level component density

Universal usage in all modular LANscape® and FutureCom™ components

10GBase-T

Ordering Information Order Number

CAXTSM-00112-C001

Description

S10TEN Module, 1xRJ45, shielded, 10GBase-T, module aqua,

with transparent TIA/EIA 568 A/B

Unit per Delivery 1/1

wire management, incl. copper

conducting tape for installation

in LANscape modular patch panels, outlets and floor box solutions

Cable Strain Relief

Using the additional cable strain relief allows increased pulling forces on the module housings. Order Number

CAXCSN-00000-C001

Description

Additional cable strain relief,

for fixing higher pulling forces

on shielded FutureCom modules

for solid wire, and for assembly of

flexible consolidation point cables

with FutureCom S10TEN fx, S250fx and U250fx modules

48

Corning Cable Systems

Unit per Delivery 100/1

FutureCom™ 10 S10 Outlets and Patch Panels TEN

TEN

Order Number

CAXTSD-S0201-C001

Unit per Delivery

Description

S10TEN Outlet, 2xRJ45,

shielded,10GBase-T,

inclined, incl. mounting frame

FutureCom F

S10TEN Outlets

Introduction

Ordering Information

1/1

FutureCom 10TEN

with grounding flaps,

central plate 50x50 mm

with designation window, screw fixing, copper conducting tape S10TEN Outlet,

2xRJ45, shielded,10GBase-T,

inclined, incl. mounting frame with

1/1

FutureCom D

CAXTSD-S0202-C001

white, RAL 9010

FutureCom E

(without faceplate),

grounding flaps, central plate 50x50 mm

FutureCom UD FutureCom UE

with designation window, screw fixing, copper conducting tape

(without faceplate)

Order Number

CAXTSV-02400-C001

Description

S10TEN Patch Panel 19“, shielded,

10GBase-T, incl. 24 FutureCom S10TEN

modules and copper conducting tape,

Unit per Delivery

Flex Wire Cable Telephone / for Patch Cord ISDN Products

S10TEN Patch Panel

Hardware

pearl white, RAL 1013

1/1

with integrated strain relief, 1 U,

for up to 24 FutureCom S10

TEN

modules, with integrated strain

1/1

Special Cable

S10TEN Patch Panel 19“,

relief, 1 U, high-grade steel front panel

Corning Cable Systems

Further Information

WAXTSV-02400-C001

Industrial Cable

high-grade steel front panel

49

FutureCom™ 10 Patch Cords RJ45 to RJ45 TEN

Description

The FutureCom™ 10TEN System patch cords consist of Cate-

gory 7 flexible cables with shielded RJ45 connectors at both

ends. The flex cables have four individual foil-shielded pairs and full braid copper shielding.

The zero halogen patch cords (LSZH) are non-corrosive

(according to IEC 60754-2), low smoke (according to IEC 61034) and flame retardant (according to IEC 60332-1). FutureCom 10TEN patch cords provide additional latch

protection. They are available in various lengths and colors.

Features

Flex cable specified up to 600 MHz

Minimum surface transfer impedance (<10 mV/m at 10 MHz)

Outstanding transmission characteristics for 10GBase-T Additional latch protection

Ordering Information CCATGB - G 1

Select color. 1 2 3 4 5 6

50

= = = = = =

gray blue yellow green red black

1

002 - A 2

2

- C0

Select length. 010 015 020 030 040 050 060 075 080 100 150 200 250 300

= = = = = = = = = = = = = =

1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 7.5 meters 8 meters 10 meters 15 meters 20 meters (gray only) 25 meters (gray only) 30 meters (gray only)

Corning Cable Systems

FutureCom™ 10 Consolidation Point Patch Cords TEN

Introduction

Description

The FutureCom™ 10TEN Consolidation Point Patch Cords are factory terminated cable assemblies with one S10TEN fx

module and one RJ45 connector. FutureCom S/FTP flex/26

FutureCom F

cable is specified up to 600 MHz and satisfies Category 7

transmission characteristics. The CP Patch Cords are suitable for connection from LANscape® Consolidation Point Hous-

FutureCom E

FutureCom 10TEN

ings to wall or desktop outlets.

Description

S/FTP flex/26 Patch Cords, 4 pairs

application-neutral, FRNC sheath,

FutureCom UD FutureCom UE

Order Number

FutureCom D

Ordering Information Length

gray, pre-terminated with one RJ45

Other lengths upon request

CP Patch Cords S/FTP flex/26 - 20

Hardware

CP Patch Cords S/FTP flex/26 - 15

5m

10 m

15 m

20 m

Flex Wire Cable Telephone / for Patch Cord ISDN Products

CCATGB-F1062-A200-C0

CP Patch Cords S/FTP flex/26 - 10

Industrial Cable

CCATGB-F1062-A150-C0

CP Patch Cords S/FTP flex/26 - 5

Special Cable

CCATGB-F1062-A100-C0

for 10GBase-T applications

Further Information

CCATGB-F1062-A050-C0

connector and one S10TEN fx module,

Corning Cable Systems

51

FutureCom™ 10 Plug & Play™ Solutions TEN

Application

The S10TEN Solution Packages are pre-terminated cables with

S10TEN modules at both ends. They are generally offered with FutureCom™ S/FTP 900/23 cables. Both modules are

equipped with additional cable strain relief to allow higher pulling force during installation (the pulling force is re-

stricted by the cable only). They enable Plug and Play™ installation and therefore significantly reduce installation

time. 100% factory testing reduces failures during installation.

Ordering Information Order Number

Description

S10 Solution Package, with TEN

S/FTP 900/23 cable,

Length

4 pairs, FRNC jacket, pre-terminated

CCATDB-F2063-A100-C0 CCATDB-F2063-A150-C0

CCATDB-F2063-A200-C0 CCATDB-F2063-A250-C0

CCATDB-F2063-A300-C0 CCATDB-F2063-A350-C0

CCATDB-F2063-A400-C0 CCATDB-F2063-A450-C0

CCATDB-F2063-A500-C0 CCATDB-F2063-A550-C0

CCATDB-F2063-A600-C0 CCATDB-F2063-A650-C0

CCATDB-F2063-A700-C0 CCATDB-F2063-A750-C0

CCATDB-F2063-A800-C0 CCATDB-F2063-A850-C0

CCATDB-F2063-A900-C0

52

with 2 S10TEN modules,

and additional cable strain relief

S10TEN Solution Package S/FTP 900/23 - 10 S10TEN Solution Package S/FTP 900/23 - 15

S10TEN Solution Package S/FTP 900/23 - 20 S10

TEN

Solution Package S/FTP 900/23 - 25

S10TEN Solution Package S/FTP 900/23 - 30

10 m 15 m

20 m

25 m

30 m

S10TEN Solution Package S/FTP 900/23 - 35

35 m

Solution Package S/FTP 900/23 - 50

50 m

S10TEN Solution Package S/FTP 900/23 - 65

65 m

S10TEN Solution Package S/FTP 900/23 - 80

80 m

S10TEN Solution Package S/FTP 900/23 - 40 S10TEN Solution Package S/FTP 900/23 - 45 S10

TEN

S10TEN Solution Package S/FTP 900/23 - 55 S10

TEN

Solution Package S/FTP 900/23 - 60

S10TEN Solution Package S/FTP 900/23 - 70 S10TEN Solution Package S/FTP 900/23 - 75

S10TEN Solution Package S/FTP 900/23 - 85

S10TEN Solution Package S/FTP 900/23 - 90

Corning Cable Systems

40 m 45 m

55 m

60 m 70 m 75 m

85 m

90 m

FutureCom™ 10 Plug & Play™ Solutions TEN

Introduction

Application

The S10TEN Plug and Play™ Solution has been especially cre-

ated for use in data center applications. This special

assembly consists of six S/FTP 900/23 cables, with a com-

FutureCom F

mon FRNC jacket. The cable is pre-terminated with six S10TEN modules at both ends. All modules are equipped with addi-

tional cable strain relief, to allow higher pulling force during

FutureCom 10TEN

installation (the pulling force is restricted by the cable only). They enable rapid Plug and Play installation in data centers and therefore significantly reduce installation time. 100%

6x S/FTP 900/23 cables with common

Length

FRNC jacket, both ends terminated

CCATDB-F2663-A200-C0 CCATDB-F2663-A300-C0

CCATDB-F2663-A400-C0

with 6 S10TEN modules,

and additional cable strain relief

S10TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 20

S10TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 30

S10TEN Plug & Play Solution Package, 6x S/FTP 900/23 - 40

*Other lengths available upon request.

Installation Option

20 m

30 m

40 m

S10TEN Plug & Play Solution Package, with 6x S/FTP 900/23 cables with common FRNC jacket, both ends terminated with 6 S10TEN modules, and additional cable strain relief: CCATDB-F2663-A200-C0

installed in a CCHE Empty Panel for 6 LANscape modules

Further Information

Special Cable

CCHE-CP00-LS

CCHE Panel with Plug & Play Solution Package

Corning Cable Systems

FutureCom UD FutureCom UE

S10 Plug & Play Solution Package, with TEN

Hardware

Description

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Order Number

Industrial Cable

Ordering Information

FutureCom D

FutureCom E

factory testing reduces failures during installation.

53

FutureCom™ 10 Universal Test Cord for Channel Testing TEN

Application

The universal channel test cord can be used for acceptance

tests of shielded FutureCom 10TEN system in conjunction with

the universal test adapter from Fluke or other test device manufactureres.

One pair of these test cords is required for acceptance tests.

Ordering Information Order Number

CCATGB-F10M0-A030-C0

Description

Universal Test Cord for the acceptance tests of the FutureCom 10

TEN

system in conjunction

with the universal test adapter from Fluke or another test device manufacturers,

2xRJ45, 4 pairs, 3 m

54

Corning Cable Systems

Units per Delivery 1/1

4.2.3. Cat. 6 F/FTP 450/23 Cable

66

4.3.1. S250 Module Overview

68

4.3. Connecting Hardware

4.3.2. Certificate for S250 Module

69

4.3.3. S250 Module

70

4.3.4. S250fx Module

71

4.4. Hardware

4.4.1. S250 Outlets and Patch Panel

72

4.4.3. Installation Options for Outlets

74

4.5.1. Cat.6 Patch Cords

75

4.4.2. S250 Double Module Outlet

73

4.5. Patch Cords

4.5.2. Consolidation Point Patch Cords

76

4.6. Plug & Play™

77

79

Special Cable

Industrial Cable

4.7. Test Cable

FutureCom F

64

FutureCom 10TEN

4.2.2. Cat. 6 S/FTP 450/23 Cable

61

FutureCom E

4.2.1. Cat. 7 S/FTP 900/23 and S/FTP 600/23 Cable

FutureCom D

4.2. Cable

FutureCom UD FutureCom UE

56

Hardware

4.1. System Descriptions & Data

Flex Wire Cable Telephone / for Patch Cord ISDN Products

FutureCom E

Further Information

4

Introduction

Table of contents

Corning Cable Systems

55

FutureCom™ E System FutureCom E is Corning’s proven system solution for symmetrical cabling. It exceeds all requirements of the current ISO/IEC

11801 (2002) and EN 50173-1 (2003) standards, Class D and E links and Categories 5 and 6 for components. In addition, the FutureCom E system also satisfies Category 5e according to TIA/EIA-568-A-5.

Face Plate “DELTAprofil”, 80x80 mm WAXWSE-00001-C001 and S250 outlet, 2xRJ45, Cat.6, inclined, CAXESD-S0201-C001

S/FTP flex/26, blue, 2xRJ45 connectors, 4 pairs, for 10/100/1000Base-T CCAEGB-G2002-A020-C0

FutureCom S/FTP 600/23 CCXEDB-F0047-C001-L7

19“ Patch Panel, for max. 24 LANscape® modules, with integrated cable strain relief, 1 U, front panel of high-grade steel WAXWSV-02400-C001

S250 Module, 1 x RJ45,shielded, Cat. 6 CAXESM-00100-C001

S/FTP flex/26, blue, 2xRJ45- connectors, 4 pairs, for 10/100/1000 Base-T CCAEGB-G2002-A020-C0 A very high level of system performance is achieved for the

The system is suitable for all recognized standardized voice

cords. The resulting performance and the future security

Ethernet (100Base-TX) and Gigabit Ethernet (1000Base-T)

link through the use of high-quality Category 6 connection

technology, Category 6 and 7 cables and Category 6 patch guaranty maximum investment protection.

Fully configured with a RJ45 connector and RJ45 module, the cabling can be used universally and is application-neutral.

56

and data transmission procedures. This applies to analog

voice transmission, ISDN,Token Ring, Ethernet (10/100Base-T), and for future high bit-rate transmission procedures.

The performance of the FutureCom E cabling system has

been certified by an independent testing body (see certificate). Of course, all standardized EMC threshold values in Europe are observed.

Corning Cable Systems

ACR in dB (typ. FutureCom E values) Min. ELFEXT in dB*

ELFEXT in dB (typ. FutureCom E values) Min. return loss in dB*

Return loss in dB (typ. FutureCom E values) * According to ISO/IEC 11801 (2002)

61.0

70.6 63.3 73

19.0

22.0

63.0 –

58.5 –

65.0 –

22.0 –

8.0

58.3 –

50.3 –

60.0 –

22.0 –

100 21.7

50.0

46.6

12.5 –

37.5 –

48.0 –

20.0 –

16.5

39.9 18.2

30.0 23.3

46.0 12.0

18.0

155.5 – 20.0 43.7 –

23.7 –

38.8 –

17.0 –

200 –

250 35.9

41.1

38.8

24.0 –

17.1 –

35.0 –

16.0 –

27.0 33.1

FutureCom F

Min. ACR in dB*

65.0

5.5

62.5 –

– 2.8 11.8

15.3

FutureCom 10TEN

72.2

Min. NEXT in dB*

2.1

20 –

33.3 8.0

15.0

FutureCom E

NEXT in dB (typ. FutureCom E values)

Attenuation in dB (typ. FutureCom™ E values)

10 –

FutureCom D

The system values cited only apply to the use of original FutureCom E products. Derived values, such as PSACR, PSNEXT, PSELFEXT, are in observance of the standard values, but are not shown. Attenuation and

Near-end Crosstalk (NEXT)

NEXT in dB (typ. FutureCom E values) min. NEXT in dB According to standard

max. Attenuation in dB According to standard

Attenuation in dB (typ. FutureCom E values)

Further Information

Special Cable

Industrial Cable

Frequency in MHz

FutureCom UD FutureCom UE

1 4.0

Hardware

Max. attenuation in dB*

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Frequency in MHz

Introduction

FutureCom™ E System Data for Channel Class E (2002)

Corning Cable Systems

57

FutureCom™ E System Data Far-end Crosstalk Relating to the Far End (ELFEXT)

ELFEXT in dB (typ. FutureCom™ E values)

Min. ELFEXT in dB According to standard

Frequency in MHz Return Loss

Return loss in dB

(typ. FutureCom E values)

min. Return loss in dB According to standard

Frequency in MHz

Test Setup

FutureCom E Test Cable, 2xRJ45, 3 m

Nominal intrinsic impedance

100 V

S250 Patch Panel 19“

Max. delay (according to standard)

0.05 µs

S250 Module, 2xRJ45

90 m FutureCom S/FTP900/23

FutureCom E Test Cable, 2 x RJ45, 3 m

58

Max. DC loop resistance (according to standard) DC loop resistance (typ. FutureCom E values) Max. delay (typ. FutureCom E values)

Corning Cable Systems

40 V 18 V

, 0.02 µs

Further Information

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

FutureCom 10TEN

FutureCom F

Introduction

FutureCom™ E Certificate 4-Connector Channel

Corning Cable Systems

59

FutureCom™ E Certificate 3-Connector Permanent Link

60

Corning Cable Systems

Foil shielding (PiMF)

FutureCom cables are low-skew products. This is increas-

PE foam-skin insulation

suitability of the cable for utilization up to the GHz area

enables the highest possible transmission speeds in futureproof networks. These cables have a streamlined construction and low weight.

Each pair is individually shielded (PiMF). The stranded pairs are additionally braid shielded (S/FTP) which guarantees outstanding shielding characteristics. The cable satisfies

Class B interference radiation standards (EN 55022) as well as immunity (EN 55024) which enables the realization of CE-compatible networks.

The FutureCom S/FTP 900/23 and 600/23 cables are also available in a triplex version. The compact construction allows flat as well as folded installation.

Further Information

Copper conductor AWG 23

ingly required for applications above 1 Gigabit-Ethernet. The

FutureCom UD FutureCom UE

tions.

Twisted pair

Hardware

transmission characteristics exceed Category 7 specifica-

Flex Wire Cable Telephone / for Patch Cord ISDN Products

designed for applications up to 1000/800 MHz and their

Industrial Cable

The FutureCom™ S/FTP 900/23 and S/FTP 600/23 cables are

Halogen-free jacket, flame retardant

Special Cable

Application

Braided shield

4 shielded pairs

FutureCom D

FutureCom E

FutureCom 10TEN

FutureCom F

Introduction

FutureCom™ E Cat. 7+ and Cat.7 Cables S/FTP 900/23 and S/FTP 600/23

Corning Cable Systems

61

FutureCom™ E Cat. 7+ and Cat.7 Cables S/FTP 900/23 and S/FTP 600/23 Features

S/FTP 900/23 specified up to 1000 MHz, S/FTP 600/23 specified up to 800 MHz Outstanding electrical characteristics

Easy and convenient installation on double and triple outlets

Compact installation of the triple cable either flat or folded (øonly 16.3 mm)

Each pair is individually foil shielded Full braid shield

Low skew between the pairs Halogen-free (LSZH)

Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034

Mechanical Characteristics

Conductor insulation Outer jacket

Area/range of application

Temperature range (installation)

Halogen-free

Foam-skin material Halogen-free,

flame retardant Dry and

damp rooms 0 to +50°C

Min. bending radius

-20 to +60°C >_ 40 mm (for 2 or 3x

installation

(4x2...) over flat side)

Operating temperature for one-time bending

Min. bending radius during Copper conductor

62

(4x2...) over flat side) >_ 60 mm (for 2 or 3x AWG 23

Electrical Characteristics (at 20°C) Largest resistance margin Insulation resistance

Impedance Zo at 0.064 MHz

Impedance Zo at 1 - 100 MHz

Impedance Zo at 101 - 250 MHz

Impedance Zo at 251 - 600 MHz Surface transfer impedance

1%

>5000 mV x km 125 V +/– 20% 100 V +/– 15%

100 V +/– 18%

100 V +/– 25% <10 m V/m

at 10 MHz

Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz Unbalance to ground dB/BZL = 100 m Unbalance to ground dB/BZL = 100 m Propagation velocity

at > 10 MHz (NVP x c) Propagation delay >_ 10 MHz Delay skew

Corning Cable Systems

>40 dB at 1 MHz

>20 dB at 100 MHz 0.79 x c

4.2 ns/m

4 ns/100 m

65.3

60.8

Attenuation in dB/100m *

2.0

Typical values in dB at 100 m

>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0

Typical values dB/100m

1.7

NEXT in dB at 100 m *

80.0

PSNEXT in dB at 100 m *

77.0

Typical values in dB at 100m

98.0

ELFEXT in dB at 100 m *

80.0

Typical values in dB at 100m

93.0

PSELFEXT in dB at 100 m *

77.0

Typical values in dB at 100m

91.0

5.7

7.2

5.0

6.5

77.0

77.0

98.0

98.0

74.0

69.9

93.0

93.0

71.0

66.9

91.0

91.0

8.1

7.3

80.0 77.0

98.0 68.0 93.0 65.0 91.0

10.1

14.5

9.2

13.2

80.0

75.1

77.0

72.5

98.0

98.0

64.1

58.1

90.0

86.0

61.1

55.1

88.0

84.0

18.5

33.3

16.8

30.0

72.4

69.4

62.3

98.0

94.0

54.0

44.5

83.0

68.0

51.0

41.5

81.0

66.0

48.9 42.5

92.0 57.8

90.0 38.4 51.0

35.4

49.0

900

55.0 –

86.0 –

84.0 – –

1000

59.0 –

83.0 –

81.0 – –













ACR in dB 98.3 95.0 93.5 92.7 90.8 86.8 83.2 66.0 49.5 31.0 24.0 * Standard: Requirements on 100 m of installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)

Electrical Characteristics (at 20°C) for S/FTP 600/23 1

Frequency in MHz

10

16

20

31.25

62.5

100

Attenuation in dB/100m *

2.0

Typical values in dB at 100m

>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0

Typical values dB/100m

5.7

1.7

NEXT in dB at 100 m *

5.0

80.0

PSNEXT in dB at 100 m *

80.0

77.0

Typical values in dB at 100m

77.0

98.0

ELFEXT in dB at 100 m *

98.0

80.0

Typical values in dB at 100m

74.0

93.0

PSELFEXT in dB at 100 m *

93.0

77.0

Typical values in dB at 100m

71.0

91.0

ACR in dB

91.0

98.3

95.0

7.2

6.5

80.0 77.0

98.0 69.9 93.0

66.9 91.0 93.5

8.1

7.3

80.0 77.0

98.0 68.0 93.0 65.0 91.0

92.7

10.1 9.2

80.0 77.0

98.0 64.1

90.0 61.1

88.0

90.8

14.5

18.5

13.2

72.4

72.5

98.0 58.1

86.0 55.1

84.0 86.8

69.4 97.0 54.0

83.0 51.0

81.0 82.1

600

65.3

60.8

33.3

16.8

75.1

300

30.7

95.0 62.3

93.0 44.5

68.0 41.5

66.0 64.3

48.9

44.0 91.0 57.8

89.0 38.4 51.0

35.4

49.0 47.0

800

53.0 –

87.0 –

85.0 – – – –

34.0 –

* Standard: Requirements on 100 m of installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)

Ordering Information Type designation

Max. Outer [ Weight Length Fire Load Halogen- Tensile Order Number Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m)

S/FTP 900/23 4P

7+

S/FTP 900/23 4P

S/FTP 900/23 8P

S/FTP 900/23 12P S/FTP 600/23 4P S/FTP 600/23 4P

S/FTP 600/23 8P

S/FTP 600/23 12P

7+

4

0.63

Yes

154

7.7

7+

12

1.89

Yes

462

7.7x25.0 195

7+ 7 7 7 7

4

8 4 4

8

12

0.63 1.26

0.63 0.63 1.26

1.89

Yes Yes Yes

Yes Yes Yes

154

308 154 154

308 462

7.7

64 64

7.7x16.5 130 7.7 7.7

64 64

7.7x16.5 130 7.7x25.0 195

* X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.

Corning Cable Systems

1000

CCXEDB-I0047-C001-L7

500

CCXEDB-I0127-C001-L6

250

500

1000 250

500 500

CCXEDB-I0047-C001-X2* CCXEDB-I0087-C001-L6

CCXEDB-F0047-C001-L7

CCXEDB-F0047-C001-X2* CCXEDB-F0087-C001-L6 CCXEDB-F0127-C001-L6

63

FutureCom F

600

FutureCom 10TEN

300

FutureCom E

100

FutureCom D

62.5

FutureCom UD FutureCom UE

80.0

31.25

Hardware

80.0

20

Flex Wire Cable Telephone / for Patch Cord ISDN Products

16

Industrial Cable

10

Special Cable

1

Frequency in MHz

Further Information

Electrical Characteristics (at 20°C) for S/FTP 900/23

Introduction

FutureCom™ E Cat. 7+ and Cat.7 Cables S/FTP 900/23 and S/FTP 600/23

FutureCom™ E Cat. 6 Cables S/FTP 450/23

Braided shield

Halogen-free jacket, flame retardant Twisted pair

Foil shielding (PiMF) 4 shielded pairs

PE foam-skin insulation

Copper conductor AWG 23

Application

The FutureCom™ S/FTP 450/23 cables are designed for applications of up to 600 MHz and their transmission characteristics exceed Category 6 specifications.

FutureCom cables are low-skew products, i.e. the skew

between the individual pairs are very low. This is increasingly required for Gigabit-Ethernet. These cables have a streamlined construction and low weight.

Each pair is individually shielded (PiMF). The stranded pairs are additionally braid shielded (S/FTP), which guarantees

outstanding shielding characteristics. The cables satisfies

Class B interference radiation standards (EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks.

Mechanical Characteristics Conductor insulation

Outer jacket

Area/range of application

Temperature range (installation) Operating temperature

Halogen-free

Foam-skin material Halogen-free,

flame retardant Dry and

damp rooms 0 to +50°C

Full braid shield

Streamlined design Lightweight

Low skew between the pairs

Low smoke according to IEC 61034

(4x2...) over flat side)

64

Each pair is shielded (PiMF)

>_ 60 mm (for 2 x

installation

Copper conductor

Outstanding electrical characteristics

Halogen-free (LSZH)

>_ 40 mm (for 2 x

Min. bending radius during

S/FTP 450/23, specified up to 600 MHz

-20 to +60°C

Min. bending radius

for one-time bending

Features

(4x2...) over flat side) AWG 23

Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC)

Corning Cable Systems

Electrical Characteristics (at 20°C) Largest resistance margin

Introduction

FutureCom™ E Cat. 6 Cables S/FTP 450/23 1%

Insulation resistance

>5000 MV x km

Impedance Zo at 0.064 MHz

125 V +/– 20%

Impedance Zo at 1 - 100 MHz

100 V +/– 18%

Unbalance to ground dB/BZL = 100 m

>40 dB at 1 MHz

Surface transfer impedance

FutureCom F

100 V +/– 15%

Impedance Zo at 101 - 250 MHz

<10 mV/m at 10 MHz / S/FTP

Unbalance to ground dB/BZL = 1000 m Unbalance to ground dB/BZL = 100 m

FutureCom 10TEN

>46 dB at 64 kHz

>20 dB at 100 MHz

Propagation velocity at > 10 MHz (NVP x c) Propagation delay >_ 10 MHz

0.79 x c

FutureCom E

4.2 ns/m

Delay skew

20

31.25

62.5

100

Attenuation in dB/100m *

2.1

Typical values in dB at 100 m

>100.0 >100.0 >100.0 >100.0 >100.0 97.0

Typical values dB/100m

6.0

1.8

NEXT in dB at 100 m *

5.3

66.0

PSNEXT in dB at 100 m *

59.3

64.0

Typical values in dB at 100m

57.3

98.0

ELFEXT in dB at 100 m *

98.0

66.0

Typical values in dB at 100m

50

93.0

PSELFEXT in dB at 100 m *

93.0

64.0

Typical values in dB at 100m

47

91.0

ACR in dB

91.0

98.2

94.7

7.6

6.8

56.2

54.2

98.0 45.9

93.0 41.0

91.0

93.2

8.5

7.6

54.8 52.8

98.0 44.0 93.0 41.0

91.0

92.4

10.8 9.6

51.9

49.9

98.0 40.1

90.0 37.1

88.0

90.4

15.5

13.6

47.4

45.4

95.0 34.1

86.0 31.1

84.0 83.4

250

19.9

33.0

95.0

90.0

17.3

44.3 42.3

93.0 30.0

83.0 27.0

81.0 77.7

27.7

38.3

36.3

88.0 22.0

70.0 19.0

68.0 62.3

450

38.0 –

85.0 –

83.0 –

54.0 –

52.0 –

47.0

600

44.8 –

75.0 –

73.0 –

48.0 –

46.0 –

30.2

* Standard: Requirements on 100 m of installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1)

Type designation

Max. Outer [ Weight Length Fire Load Halogen- Tensile Category No. of Pairs (MJ/m) free Order Number Strength(N) (mm) (kg/km) (m)

S/FTP 450/23 4P

6

S/FTP 450/23 4P

S/FTP 450/23 8P

6 6

4 4

8

0.57 0.57 1.14

Yes Yes Yes

145 145

290

7.9 7.9

55 55

7.5x16.6 120

* X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.

Corning Cable Systems

1000 250

500

Industrial Cable

Ordering Information

FutureCom UD FutureCom UE

16

Hardware

10

Flex Wire Flex Wire CableCable Telephone / for Patch for Patch Cord Cord ISDN Products

1

CCXEDB-D0047-C001-L7

CCXEDB-D0047-C001-X2* CCXEDB-D0087-C001-L6

65

Special Cable

Frequency in MHz

Further Information

Electrical Characteristics (at 20°C)

FutureCom D

4 ns/100 m

FutureCom™ E Cat. 6 Cables F/FTP 450/23

Foil shield (FTP)

Halogen-free jacket, flame retardant Twisted pair

Foil shielding (PiMF)

4 shielded pairs Additional wire

PE foam-skin insulation Copper conductor AWG 23

Mechanical Characteristics Conductor insulation

Outer jacket

Area/range of application

Temperature range (installation) Operating temperature

Halogen-free

Foam-skin material Halogen-free,

flame retardant Dry and

damp rooms 0 to +50°C

FutureCom cables are low-skew products, i.e. the skew

between the individual pairs are very low. This is increasingly required for Gigabit-Ethernet. These cables have a streamlined construction and low weight.

Each pair is individually shielded (PiMF). The stranded pairs

are additionally foil shielded (F/FTP), which guarantees out-

standing shielding characteristics. The cables satisfies Class

B interference radiation standards (EN 55022), as well as im-

munity (EN 55024), which enables the realization of CE-compatible networks.

Features

F/FTP flex cable, specified up to 450 MHz Outstanding electrical characteristics Each pair is shielded (PiMF)

Full foil shielding and additional copper wire Streamlined design Lightweight

Low skew between the pairs

Low smoke according to IEC 61034

(4x2...) over flat side)

66

characteristics exceed Category 6 specifications.

>_ 60 mm (for 2 x

installation

Copper conductor

applications of up to 450 MHz and their transmission

Halogen-free (LSZH)

>_ 40 mm (for 2 x

Min. bending radius during

The FutureCom™ F/FTP 450/23 cables are designed for

-20 to +60°C

Min. bending radius

for one-time bending

Application

(4x2...) over flat side) AWG 23

Fire retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC)

Corning Cable Systems

Electrical Characteristics (at 20°C) Largest resistance margin

Introduction

FutureCom™ E Cat. 6 Cables F/FTP 450/23 2%

Insulation resistance

>5000 MV x km

Impedance Zo at 0.064 MHz

125 V +/– 20%

Impedance Zo at 1 - 100 MHz

100 V +/– 18%

Unbalance to ground dB/BZL = 100 m

>40 dB at 1 MHz

Surface transfer impedance

FutureCom F

100 V +/– 15%

Impedance Zo at 101 - 250 MHz

100 mV/m at 10 MHz

Unbalance to ground dB/BZL = 1000 m Unbalance to ground dB/BZL = 100 m

FutureCom 10TEN

>46 dB at 64 kHz

>20 dB at 100 MHz

Propagation velocity at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

0.79 x c

FutureCom E

4.3 ns/m

Delay skew

20

59.3

56.2

54.8

31.25

62.5

100

250

51.9

47.4

44.3

38.3

Attenuation in dB/100m *

2.1

Typical values in dB at 100 m

>100.0 >100.0 >100.0 >100.0 >100.0 97.0

Typical values dB/100m

1.8

NEXT in dB at 100 m *

66.0

PSNEXT in dB at 100 m *

64.0

Typical values in dB at 100m

98.0

ELFEXT in dB at 100 m *

66.0

Typical values in dB at 100m

93.0

PSELFEXT in dB at 100 m *

64.0

Typical values in dB at 100m

91.0

ACR in dB

98.2

6.0 5.3

57.3

98.0 50

93.0 47

91.0

94.7

7.6

6.8

54.2

98.0 45.9

93.0 41.0

91.0

93.2

8.5

7.6

52.8

98.0 44.0 93.0 41.0

91.0

92.4

10.8 9.6

49.9

98.0 40.1

90.0 37.1

88.0

90.4

15.5

13.6

45.4

95.0 34.1

86.0 31.1

84.0 83.4

19.9 17.3

95.0 42.3

93.0 30.0

83.0 27.0

81.0 77.7

33.0 27.7

90.0 36.3

88.0 22.0

70.0 19.0

68.0 62.3

450

38.0 –

85.0 –

83.0 –

54.0 –

52.0 –

47.0

* Standard: Requirements on 100 m of installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1)

Type designation

Max. Outer [ Weight Length Fire Load Halogen- Tensile Category No. of Pairs (MJ/m) free Order Number Strength(N) (mm) (kg/km) (m)

F/FTP 450/23 4P

6

F/FTP 450/23 4P

F/FTP 450/23 8P

6 6

4 4

8

0.57 0.57 1.16

Yes Yes Yes

105 105

210

7.4 7.4

50 50

7.4x15.5 100

* X2 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.

Corning Cable Systems

1000 250

500

Industrial Cable

Ordering Information

FutureCom UD FutureCom UE

16

Hardware

10

Flex Wire Cable Telephone / for Patch Cord ISDN Products

1

CCXDDA-D0047-C001-L7

CCXDDA-D0047-C001-X2* CCXDDA-D0087-C001-L6

67

Special Cable

Frequency in MHz

Further Information

Electrical Characteristics (at 20°C)

FutureCom D

4 ns/100 m

FutureCom™ E Module Overview Features

Fully compatible with all modular LANscape® systems Wide range of installation options Few individual components

High-level component density Individual shielding Halogen-free

Fire class UL94V-0

Optimized construction with printed circuit board for bandwidths of more than 300 MHz 1500 connector cycles are possible

Proven IDC technology for wires with AWG 24 to AWG 22 Module reusable several times

Individual Components of the S250 Module

Disassembled S250 Basic Module

Features

Wire management using TIA/EIA 568 A/B coding Installation in pairs

(no untwisting of the pairs necessary) Rapid assembly time Easy handling

Compatible with all FutureCom™ S/FTP and F/FTP cables

Wire Management

68

Corning Cable Systems

Further Information

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

FutureCom 10TEN

FutureCom F

Introduction

FutureCom™ E Certificate Cat.6 De-embedded for S250 Modules

Corning Cable Systems

69

FutureCom™ E S250 Module Features

Easy and quick to install, no special tools required

IDC connection (IDC = Insulation Displacement Contacts) High-level component density

Universal usage in all modular LANscape® and FutureCom™ components

Category 6 (2002), de-embedded

Ordering Information Order Number

CAXESM-00100-C001

Description

S250 Module, 1xRJ45, shielded, Cat.6,

incl. copper conducting tape for installation in LANscape modular patch panels,

Unit per Delivery 1/1

outlets and floor box solutions

CAXESM-00200-C001

S250 Double Module, 2xRJ45, shielded, Cat.6, incl. copper conducting tape for installation in LANscape modular patch panels,

1/1

outlets and floor box solutions

Cable Strain Relief

Using the additional cable strain relief allows increased pulling force on the module housings. Order Number

CAXCSN-00000-C001

Description

Additional cable strain relief,

for higher pulling force on shielded FutureCom modules for solid wire,

and for assembly of flexible consolidation point cables with FutureCom S10TEN fx, S250fx or U250fx modules

70

Corning Cable Systems

Unit per Delivery 100/1

FutureCom™ E S250fx Module Introduction

Application

S250fx Modules are used for the assembly of flexible cables or consolidation point cables.

FutureCom F

Features

Fully compatible with all modular LANscape® connecting

Individual shielding

Proven IDC technology for AWG 24 and AWG 26 stranded Individual components of the S250fx Module

1500 connector cycles are possible

Wire management using A/B printing according to TIA/EIA 568

Installation in pairs (no untwisting of the pairs is necessary)

Category 6, de-embedded

FutureCom UD FutureCom UE

Easy handling and very short assembly time

Requirements for Consolidation Points

For the assembly of modules with flexible cables, an additional cable strain relief must be used

CCS patch cords (with RJ45 connectors) are wired

according to TIA/EIA 568 B; when using other single-

ended pre-terminated connecting cables they should be

Ordering Information

S250fx Module, 1xRJ45, shielded, Cat.6,

especially suitable for consolidation point cable with AWG 24/26 stranded wires,

Unit per Delivery 1/1

incl. copper conducting tape and

Special Cable

CAXESM-00100-C003

Description

additional cable strain relief for installation in LANscape hardware

Further Information

Order Number

attenuation specification than the flexible cable

Industrial Cable

Assembled S250fx Module with Additional Cable Strain Relief

wired according to the RJ45 connector scheme

The installed solid wire cable should have a lower

Hardware

Module reusable several times

Flex Wire Cable Telephone / for Patch Cord ISDN Products

wires

FutureCom D

Wide range of installation options

FutureCom E

FutureCom 10TEN

hardware

Corning Cable Systems

71

FutureCom™ E S250 Outlets and Patch Panel Ordering Information S250 Outlets Order Number

Description

S250 Outlet, 2xRJ45,

shielded, Cat. 6, inclined,

Unit per Delivery

incl. mounting frame

with grounding flaps,

central plate 50x50 mm

with designation window, screw-fixed, copper CAXESD-S0201-C001

CAXESD-S0202-C001

S250 Patch Panel

Order Number

CAXESV-02400-C001

conducting tape

(without face plate) white, RAL 9010

1/1

pearl white, RAL 1013

1/1

Description

Unit per Delivery

S250 Patch Panel 19“,

shielded, Cat. 6, including 24 FutureCom S250

1/1

modules and copper conducting tape, with integrated

cable strain relief,

1 U, high-grade steel front panel

Patch panel accessories please see page 156.

72

Corning Cable Systems

Order Number

CAXESD-S0200-C001

Description

S250 Double Module Outlet, 2xRJ45, Cat. 6, inclined,

incl. mounting frame with

Unit per Delivery 1/1

FutureCom F

Ordering Information

Introduction

FutureCom™ E S250 Double Module Outlet

grounding flaps and

FutureCom 10TEN

copper conducting tape

(suitable for Rutenbeck-

compatible central plates

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

or faceplates)

Installation Option

S250 Double Module Outlet, 2xRJ45, Cat. 6, inclined, incl. mounting frame and copper conducting tape.

Hardware

CAXESD-S0200-C001

For example, mounted with a high grade steel face plate

Further Information

Special Cable

S250 Double Module Outlet with face plate (Jung)

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

from Jung

Corning Cable Systems

73

FutureCom™ E Outlet Installation Options Option 1: 6-Port Frame Set for the installation of 6

LANscape® fiber optic or FutureCom™ modules, inclined, in-

cluding mounting frame and two triple housings with designation window and dust protection flaps as well as 151x80 mm face plate, white, RAL 9010: WAXWSE-V0601-C001

equipped with two S250 modules CAXESM-00100-C001

two black labeling icons WAXWSE-00008-C001

four blue labeling icons WAXWSE-00004-C001

6-Port Frame Set, inclined

and two blue S/FTP flex/26 Patch Cords CCAEGB-D2002-A030-C0

Option 2: S250 Inclined Outlet with two S250 Modules,

white, RAL 9010 in the race-way: CAXESD-S0201-C001

equipped with one black labeling icon WAXWSE-00008-C001

and one blue labeling icon WAXWSE-00004-C001

Built into a Tehalit race-way

S250 Inclined Outlet with two S250 Modules

Option 3: Double Surface Outlet for the mounting of 2 LAN-

scape modules, inclined, including face plate and double housing with designation window and dust protection flaps, white, RAL 9010:

WAXWSE-V0201-C001

equipped with two S250 modules CAXESM-00100-C001

one gray labeling icon

WAXWSE-00003-C001

one green labeling icon WAXWSE-00006-C001

and one green S/FTP flex/26 Patch Cord

2-Port Surface Mount Outlet

CCAEGB-D4002-A020-C0

using one surface mount housing WAXWSE-00001-C003

... and one “DELTAfläche” face plate

74

Corning Cable Systems

FutureCom™ E Cat. 6 Patch Cords RJ45 to RJ45 Introduction

Description

The FutureCom E System patch cords consist of Category 6 flex cable with shielded RJ45 connectors at both ends. The flex cables have four individual foil-shielded pairs and full

FutureCom F

braid copper shielding. The zero halogen patch cords (LSZH) are non-corrosive (according to IEC 60754-2), low smoke

(according to IEC 61034) and flame retardant (according to

FutureCom 10TEN

IEC 60332-1, Category B). They are available in various lengths and colors.

FutureCom E

Features

FutureCom D

S/FTP flex cable, specified up to 600 MHz

Application-neutral due to using all four pairs Minimum surface transfer impedance (<10 mV/m at 10 MHz)

FutureCom UD FutureCom UE

Outstanding transmission characteristics according to Channel E (2002)

1 2 3 4 5 6

= = = = = =

gray blue yellow green red black

2

2

- C0

Select length. 010 015 020 030 040 050 060 075 080 100 150 200 250 300

= = = = = = = = = = = = = =

1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 7.5 meters 8 meters 10 meters 15 meters 20 meters (gray only) 25 meters (gray only) 30 meters (gray only)

Corning Cable Systems

Industrial Cable

Select color.

002 - A

Special Cable

1

1

Further Information

CCAEGB - G

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Ordering Information

Hardware

Cat. 6

75

FutureCom™ E Consolidation Point Patch Cords Description

The FutureCom™ E Consolidation Point Patch Cords are

factory terminated cable assemblies with one S250 fx

module and one RJ45 connector. FutureCom S/FTP flex/26 Cable is specified up to 600 MHz and satisfies Category 7

transmission characteristics. The CP Patch Cords are suitable to connect LANscape® Consolidation Point Housings to wall

or desktop outlets.

Ordering Information Order Number

Description

S/FTP flex/26 Patch Cords,

4 pairs, application-neutral, FRNC sheath,

Length

gray, pre-terminated with one RJ45 CCAEGB-D1052-A050-C0 CCAEGB-D1052-A100-C0 CCAEGB-D1052-A150-C0

CCAEGB-D1052-A200-C0

Other lengths upon request

76

connector and one S250fx module, Cat. 6,

for example 10/100/1000Base-T

CP Patch Cords S/FTP flex/26 - 5

CP Patch Cords S/FTP flex/26 - 10 CP Patch Cords S/FTP flex/26 - 15

CP Patch Cords S/FTP flex/26 - 20

Corning Cable Systems

5m

10 m 15 m

20 m

FutureCom™ E Plug & Play™ Solutions Introduction

Application

The S250 Solution Packages are pre-terminated cables with

S250 modules at both ends. They are generally offered with

FutureCom F

FutureCom™ S/FTP 900/23 cables. Both modules are

equipped with additional cable strain relief, to allow higher

pulling forces during insertion (the pulling force is restricted

FutureCom 10TEN

by the cable only). They enable Plug and Play™ installation

CCAEDB-D2050-A250-C0

CCAEDB-D2050-A300-C0 CCAEDB-D2050-A350-C0

CCAEDB-D2050-A400-C0 CCAEDB-D2050-A450-C0

CCAEDB-D2050-A500-C0 CCAEDB-D2050-A550-C0

CCAEDB-D2050-A600-C0 CCAEDB-D2050-A650-C0

CCAEDB-D2050-A700-C0 CCAEDB-D2050-A750-C0

CCAEDB-D2050-A800-C0 CCAEDB-D2050-A850-C0

CCAEDB-D2050-A900-C0

with 2 S250 modules

and additional cable strain relief

S250 Solution Package S/FTP 900/23 - 10

10 m

S250 Solution Package S/FTP 900/23 - 25

25 m

S250 Solution Package S/FTP 900/23 - 15

S250 Solution Package S/FTP 900/23 - 20 S250 Solution Package S/FTP 900/23 - 30 S250 Solution Package S/FTP 900/23 - 35

15 m

20 m

30 m 35 m

S250 Solution Package S/FTP 900/23 - 40

40 m

S250 Solution Package S/FTP 900/23 - 55

55 m

S250 Solution Package S/FTP 900/23 - 70

70 m

S250 Solution Package S/FTP 900/23 - 45

S250 Solution Package S/FTP 900/23 - 50

S250 Solution Package S/FTP 900/23 - 60 S250 Solution Package S/FTP 900/23 - 65 S250 Solution Package S/FTP 900/23 - 75

S250 Solution Package S/FTP 900/23 - 80 S250 Solution Package S/FTP 900/23 - 85

S250 Solution Package S/FTP 900/23 - 90

45 m

50 m

60 m 65 m 75 m

80 m 85 m

90 m

Hardware

CCAEDB-D2050-A200-C0

4 pairs, FRNC jacket pre-terminated

Flex Wire Cable Telephone / for Patch Cord ISDN Products

CCAEDB-D2050-A150-C0

Solution Package, S/FTP900/23 cable,

Length

Industrial Cable

CCAEDB-D2050-A100-C0

Description

Further Information

Order Number

Special Cable

Ordering Information

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

and therefore significantly reduce installation time.

Corning Cable Systems

77

FutureCom™ E Plug & Play™ Solutions Application

The S250 Plug and Play™ Solution has been especially created for use in data center applications. This special

assembly consists of six S/FTP 900/23 cables, with a com-

mon FRNC jacket. The cable is pre-terminated with six S250 modules at both ends. All modules are equipped with addi-

tional cable strain relief, to allow higher pulling force during

installation (the pulling force is restricted by the cable only). They enable rapid Plug and Play installation in data centers and therefore significantly reduce installation time. 100% factory testing reduces failures during installation.

Ordering Information Order Number

Description

S250 Plug & Play Solution Package, with

6x S/FTP 900/23 cables with common

Length

FRNC jacket, both ends terminated

CCAEDB-D2650-A200-C0 CCAEDB-D2650-A300-C0

CCAEDB-D2650-A400-C0

with 6 S250 modules,

and additional cable strain relief

S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 20 S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 30

S250 Plug & Play Solution Package, 6x S/FTP 900/23 - 40

Other lengths available upon request.

Installation Option

20 m

30 m

40 m

S250 Plug & Play Solution Package, with 6x S/FTP 900/23 cables with common FRNC jacket, both ends terminated with 6 S250 modules, and additional cable strain relief: CCAEDB-D2650-A200-C0

installed in a CCHE Empty Panel for 6 LANscape modules CCHE-CP00-LS

CCHE Panel with Plug & Play Solution Package

78

Corning Cable Systems

FutureCom™ E Universal Test Cord for Channel Testing Introduction

Application

The universal channel test cord can be used for acceptance

tests of shielded FutureCom™ E Systems in conjunction with

the universal test adapter from Fluke or other test device

FutureCom F

manufactureres.

of the FutureCom E System in conjunction

with the universal test adapter from Fluke

FutureCom E

Universal Test Cord, for the acceptance test

Units per Delivery 1/1

or other test device manufacturers,

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

2xRJ45, 4 pairs, 3 m

Special Cable

CCAEGB-D10M0-A030-C0

Description

Further Information

Order Number

FutureCom D

Ordering Information

FutureCom 10TEN

One pair of these test cords is required for acceptance tests.

Corning Cable Systems

79

80

Corning Cable Systems

5.3.1. Cat. 5 SF/UTP 300/24 FRNC/PVC Cable

86

5.3.3. Cat. 5 F/UTP 300/24 FRNC/PVC Cable

90

5.4.1. S100e Module Overview

92

5.3.2. Cat. 5 SF/UTP 300/24 FRNC, 16P Cable 5.4. Connecting Hardware

5.4.2. S100e and S100eL Module

88

93

5.5. Hardware

5.5.1. S100e Outlets and Patch Panels

94

5.5.3. S100eL Outlets and Patch Panels

96

5.5.2. S100e Double Module Outlet

95

5.5.4. Installation Options for Outlets

97

5.6. Patch Cords

98

99

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

5.7. Plug & Play™

FutureCom F

5.3. Cable

FutureCom 10TEN

85

FutureCom E

5.2. Certificates

FutureCom D

82

FutureCom UD FutureCom UE

5.1. System Descriptions & Data

Hardware

FutureCom D

Further Information

5

Introduction

Table of contents

Corning Cable Systems

81

FutureCom™ D System FutureCom D (2002) is Corning’s Class D system solution for symmetrical cabling. It fulfils all requirements of the current

ISO/IEC 11801 (2002) and EN 50173-1 (2003) standards, Class D for links and Category 5 for the components. In addition, the FutureCom D system also satisfies Category 5e according to TIA/EIA-568-A-5.

Face Plate “DELTAprofil”, 80x80 mm WAXWSE-00001-C001 and S100e outlet, 2xRJ45, Cat.5, inclined, CAXDSD-S0201-C001

SF/UTP flex/26, green, 2xRJ45 connectors, 4 pairs, for 10/100/1000Base-T CCADGF-D4002-A030-C0

FutureCom SF/UTP 300/24 Cable CCXDEF-I0047-C001-L7

19“ Patch Panel, for max. 24 LANscape® modules, with integrated cable strain relief, 1 U, front panel of high-grade steel WAXWSV-02400-C001

S100e Module, 1xRJ45, shielded, Cat. 5 CAXDSM-00100-C001

SF/UTP flex/26, green, 2xRJ45- connectors, 4 pairs, for 10/100/1000 Base-T CCADGF-D4002-A020-C0

A high level of system performace is achieved for the entire

FutureCom D cabling that conforms to the standards is

mace, and future security, guarantees a high degree of

mission, ISDN, Token Ring, Ethernet (10-Base-T), Ethernet

link through the use of high-quality Category 5 connection

technology, cables and patch cords. The resulting perforinvestment protection for the cabling.

Fully configured with RJ45 connectors and RJ45 modules, the cabling is application-neutral and can be used universally.

82

suitable for all recognized standardized voice and data

transmission procedures. This applies to analog voice trans(100Base-TX) and Gigabit Ethernet (1000Base-T).

The performance of the FutureCom D cabling system has

been certified by an independent test body (see certificate). Of course, all standardized EMC threshold values in Europe are observed.

Corning Cable Systems

ACR in dB (typ. FutureCom D values) Min. ELFEXT in dB*

ELFEXT in dB (typ. FutureCom D values) Min. return loss in dB*

Return loss in dB (typ. FutureCom D values) * According to ISO/IEC 11801 (2002)

70.0 56.0 67.7 57.4

70.0 17.0

19.0

60.0 –

56.5 –

60.0 –

20.0 –

55.0 –

49.2 –

52.0 –

20.0 –

43.6 51.0

34.5

44.0 33.3

48.0 17.0

20.0

8.5 –

48.0 –

39.2 –

46.0 –

19.5 –

10.0 –

44.0 –

34.0 –

43.0 –

19.0 –

62.5 16.0 –

38.0 –

22.0 –

38.0 –

17.0 –

100

24.0 19.0 30.1

36.0 6.1

17.0 17.4

34.0 10.0 13.0

The system values cited are only valid with regard to the use of original FutureCom D products. Derived values, such as PSACR, PSNEXT and PSELFEXT, maintain the required standard values but are not shown for clarity of presentation. Attenuation and

Near-end Crosstalk (NEXT)

NEXT in dB (typ. FutureCom D values) min. NEXT in dB According to standard

max. Attenuation in dB According to standard

Attenuation in dB (typ. FutureCom D values)

Further Information

Special Cable

Industrial Cable

Frequency in MHz

FutureCom F

Min. ACR in dB*

60.0

7.0

9.1

31.25

FutureCom 10TEN

NEXT in dB (typ. FutureCom D values)

5.8 –

20

FutureCom E

Min. NEXT in dB*

3.5 –

16

FutureCom D

2.3

4.0

10

FutureCom UD FutureCom UE

Attenuation in dB (typ. FutureCom™ D values)

Max. attenuation in dB*

4

Hardware

1

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Frequency in MHz

Introduction

FutureCom™ D System Data for Channel Class D (2002)

Corning Cable Systems

83

FutureCom™ D System Data Far-end Crosstalk Relating to the Far End (ELFEXT)

ELFEXT in dB (typ. FutureCom™ D values)

Min. ELFEXT in dB According to Norm

Frequency in MHz Return Loss

Return loss in dB

(typ. FutureCom D values)

min. return loss in dB according to standard

Frequency in MHz

Test Setup

FutureCom™ D SF/UTP flex/26 Connecting Cable, 3 m S100e Modules, 2xRJ45

90 m FutureCom SF/UTP300/24

S100e Patch Panel 19“

FutureCom D SF/UTP flex/26 Patch Cord, 3 m

84

Nominal intrinsic impedance

100 V

Max. delay (according to standard)

0.05 µs

Max. DC loop resistance (according to standard) DC loop resistance (typ. FutureCom D values) Max. delay (typ. FutureCom D values)

Corning Cable Systems

40 V 18 V

, 0.02 µs

Further Information

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

FutureCom 10TEN

FutureCom F

Introduction

FutureCom™ D Certificates

Corning Cable Systems

85

FutureCom™ D Cat. 5 Cable SF/UTP 300/24 FRNC or PVC

Braided shield

Halogen-free jacket, flame retardant or PVC Twisted pair

Foil shielding

4 shielded pairs

PE foam-skin insulation

Copper conductor AWG 24

Application

The FutureCom SF/UTP 300/24 cable is designed for applications of up to 300 MHz and its transmission characteristics

exceed Category 5 (2002) and Category 5e (TIA/EIA-568-A-5) specifications.

FutureCom cables are low-skew products, i.e. the skew

between the individual pairs is very low. This is increasingly required for Gigabit-Ethernet. The cable has a streamlined construction and low weight.

The four stranded pairs are sheathed with a foil shield

(F/UTP) and, additionally, with a braided shield (SF/UTP),

which guarantee outstanding shielding characteristics. The

cable satisfies the standard for Class B interference radiation

Color Coding Pair 1

Pair 2 Pair 3

Pair 4

(EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks. white with blue rings/blue

white with orange rings/orange white with green rings/green

white with brown rings/brown

Features

SF/UTP 300/24 cable, specified up to 300 MHz Outstanding electrical characteristics Full braid copper shield Streamlined design Lightweight

Low skew between the pairs

Halogen-free (LSZH) jacket

Flame retardant according to IEC 60332-3, Category C PVC jacket, flame retardant, according to IEC 60332-1, Category B

FRNC is non-corrosive according to IEC 60754-2

86

Corning Cable Systems

damp rooms

Unbalance to ground dB/BZL = 100 m

Min. bending radius

>_ 35 mm (for 2 x

installation

(4x2...) over flat side)

Unbalance to ground dB/BZL = 100 m Propagation velocity

(4x2...) over flat side)

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

>_ 50 mm (for 2 x

Electrical Characteristics (at 20°C)

1

Frequency in MHz

10

16

50.3

47.2

Attenuation in dB/100m *

2.1

6.3

Typical values in dB at 100m

77.0

62.0

Typical values dB/100m

2.0

NEXT in dB at 100 m*

65.3

PSNEXT in dB at 100 m *

62.3

Typical values in dB at 100m

75.0

ELFEXT in dB at 100 m *

63.8

Typical values in dB at 100m

72.0

PSELFEXT in dB at 100 m *

60.8

Typical values in dB at 100m

70.0

ACR in dB

75.0

5.6

47.3

60.0 43.8

60.0 40.8 58.0 56.4

20

>20 dB at 100 MHz 0.74 x c

4.5 ns/m

Delay skew

AWG 24

Copper conductor

>40 dB at 1 MHz

7 ns/100 m

31.25

62.5

100

8.0

9.0

11.4

16.5

21.3

59.0

57.0

54.0

50.0

46.0

7.2

44.2 57.0 39.7

54.0 36.7

52.0 51.8

8.0

45.8

42.8 55.0 37.8

52.0

34.8

50.0

49.0

10.1

42.9

39.9 52.0

33.9

48.0 30.9

46.0 43.9

14.4

38.4 35.4

48.0 27.9

40.0 24.9 38.0 35.6

18.2

35.3

32.3

44.0 23.8

34.0 20.8 32.0 27.8

250

29.5 –

38.5 –

36.5 –

22.1 –

20.1 –

9.0

* Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms with EN 50288-2-1)

Ordering Information Type designation

Category

No. of Pairs

SF/UTP 300/24 4P

5e (FRNC)

4

SF/UTP 300/24 4P

SF/UTP 300/24 8P SF/UTP 300/24 4P SF/UTP 300/24 4P

SF/UTP 300/24 8P

5e (FRNC) 5e (FRNC) 5e (PVC) 5e (PVC) 5e (PVC)

4

8 4 4

8

Max. Outer [ Weight Length Fire Load Halogen- Tensile (kg/km) (m) Order Number Strength(N) (mm) (MJ/m) free 0.46

FutureCom D

-20 to +60°C

Min. bending radius during

at 10 MHz

Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz

0 to +50°C

for one-time bending

<10 m V/m

300

32.2 –

35.0 –

33.0 –

17.0 –

15.0 –

2.8

0.46

Yes

82

6.1

50

1000

CCXDEF-C0047-C001-L7

0.41

No

82

5.8

45

1000

CCXDLF-C0047-C001-L7

0.96 0.41

0.94

Yes Yes No No

82

164 82

164

6.1

50

6.2x13.5 100 5.8

45

6.2x13.5 97

* X1 cables are delivered in a Reelex box. All other cables are delivered on disposable reels.

Corning Cable Systems

305

1000 305

1000

FutureCom F

Dry and

Operating temperature

100 V +/– 15%

Surface transfer impedance

FutureCom 10TEN

Impedance Zo at 1 - 100 MHz

flame retardant

Temperature range (installation)

125 V +/– 20%

FutureCom E

Halogen-free,

Area/range of application

>5000 MV x km

Impedance Zo at 0.064 MHz

FutureCom UD FutureCom UE

Foam-skin

Hardware

Sheath material

1%

Insulation resistance

CCXDEF-C0047-C001-X1* CCXDEF-C0087-C001-L7

CCXDLF-C0047-C001-X1* CCXDLF-C0087-C001-L7

87

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Largest resistance margin

FRNC: Halogen-free

Industrial Cable

PE Foam skin

Special Cable

PVC:

Conductor insulation

Electrical Characteristics (at 20°C)

Further Information

Mechanical Characteristics

Introduction

FutureCom™ D Cat. 5 Cable SF/UTP 300/24 FRNC or PVC

FutureCom™ D Cat. 5 Cable SF/UTP 300/24 FRNC, 16P

Halogen-free external jacket, flame retardant Foil

Halogen-free jacket, flame retardant Braided shield

Foil shielding Metal-free central element Twisted pair

4 shielded pairs Foam-skin PE insulation

Copper conductor AWG 24

Application

The FutureCom™ SF/UTP 300/24 16P cable is specified for applications up to 300 MHz and its transmission

characteristics exeed Category 5 (2002) and Category 5e (TIA/EIA 568-A-5).

FutureCom cables are low-skew products, i.e. the skew

between the individual pairs is very low. This is increasingly required for Gigabit-Ethernet.

The four stranded pairs are foil shielded (F/UTP) additionally with a braided shield (SF/UTP), which guarantees outstand-

ing shielding characteristics. The cable satisfies the standard for Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of CEcompatible networks. The Quattro configuration with a

shared external sheath for the FutureCom SF/UTP 300/24 16P cable, allows increased mechanical load and enables

Color Coding Pair 1

Pair 2 Pair 3

Pair 4

cost-optimized installation.

white with blue rings/blue

white with orange rings/orange

white with green rings/green

white with brown rings/brown

Features

SF/UTP 300/24 cable, specified up to 300 MHz Outstanding electrical characteristics

Stranded pairs with foil shield and full braid shield. The 4 cable cores are twisted around a non-metallic central element

Low skew between the pairs

Halogen-free (LSZH)

Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034

88

Corning Cable Systems

Min. bending radius

for one-time bending

Min. bending radius during

0 to +50°C

at 10 MHz

Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz

-20 to +60°C

Unbalance to ground dB/BZL = 100 m

>_ 85 mm

Unbalance to ground dB/BZL = 100 m Propagation velocity

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

AWG 24

Copper conductor

<10 m V/m

1

Frequency in MHz

10

16

50.3

47.2

Attenuation in dB/100m *

2.1

6.3

Typical values in dB at 100m

77.0

62.0

Typical values dB/100m

2.0

NEXT in dB at 100 m*

65.3

PSNEXT in dB at 100 m *

62.3

Typical values in dB at 100m

75.0

ELFEXT in dB at 100 m *

63.8

Typical values in dB at 100m

72.0

PSELFEXT in dB at 100 m *

60.8

Typical values in dB at 100m

70.0

ACR in dB

75.0

5.6

47.3

60.0 43.8

60.0 40.8 58.0 56.4

20

>20 dB at 100 MHz 0.74 x c

4.5 ns/m

Delay skew

Electrical Characteristics (at 20°C)

>40 dB at 1 MHz

7 ns/100 m

31.25

62.5

100

8.0

9.0

11.4

16.5

21.3

59.0

57.0

54.0

50.0

46.0

7.2

44.2 57.0 39.7

54.0 36.7

52.0 51.8

8.0

45.8

42.8 55.0 37.8

52.0

34.8

50.0

49.0

10.1

42.9

39.9 52.0

33.9

48.0 30.9

46.0 43.9

14.4

38.4 35.4

48.0 27.9

40.0 24.9 38.0 35.6

18.2

35.3

32.3

44.0 23.8

34.0 20.8 32.0 27.8

250

29.5 –

38.5 –

36.5 –

22.1 –

20.1 –

9.0

* Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms with EN 50288-2-1)

300

32.2 –

35.0 –

33.0 –

17.0 –

15.0 –

2.8

SF/UTP 300/24 16P

Industrial Cable

Ordering Information Type designation

Max. Outer [ Weight Length Fire Load Halogen- Tensile Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number 5e

16

4.04

Yes

328

16.5

Corning Cable Systems

280

1000

FutureCom F

damp rooms

>_ 120 mm

installation

100 V +/– 15%

Surface transfer impedance

FutureCom 10TEN

Operating temperature

Impedance Zo at 1 - 100 MHz

Dry and

FutureCom D

Temperature range (installation)

125 V +/– 20%

FutureCom E

flame retardant

Area/range of application

>5000 MV x km

Impedance Zo at 0.064 MHz

FutureCom UD FutureCom UE

Halogen-free,

Outer jacket

1%

Insulation resistance

Hardware

Largest resistance margin

Foam-skin material

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Halogen-free

CCXDEF-C0167-C001-L7

89

Special Cable

Conductor insulation

Electrical Characteristics (at 20°C)

Further Information

Mechanical Characteristics

Introduction

FutureCom™ D Cat. 5 Cable SF/UTP 300/24 FRNC, 16P

FutureCom™ D Cat. 5 Cable F/UTP 300/24 FRNC or PVC

Foil shielding

PVC or halogen-free jacket, flame retardant Twisted pair

Foil shielding

Additional wire

PE foam-skin insulation Copper conductor AWG 24 4 shielded pairs

Color Coding

white with blue rings/blue

Pair 4

white with orange rings/orange

Pair 3

The FutureCom™ F/UTP 300/24 Cable is designed for applications of up to 300 MHz and its transmission characteristics

exceed Category 5 (2002) and Category 5e (TIA/EIA-568-A-5) specifications.

FutureCom cables are low-skew products, i.e. the skew be-

tween the individual pairs are very low. This is increasingly required for Gigabit-Ethernet. The cable has a streamlined construction and low weight.

The four stranded pairs are foil shielded (F/UTP). The cable

satisfies the standards for Class B interference radiation

(EN 55022), as well as immunitiy (EN 55024), which enables the realization of CE-compatible networks.

Pair 1

Pair 2

Application

white with orange rings/orange white with orange rings/orange

Features

F/UTP 300/24 cable, specified up to 300 MHz Outstanding electrical characteristics

Full shielding with 2 foils and additional copper wire Streamlined design Lightweight

Low skew between the pairs Halogen-free (LSZH) jacket

Flame retardant according to IEC 60332-3, Category C PVC jacket, flame retardant according to IEC 60332-1, Category B

Non-corrosive according to IEC 60754-2 (FRNC)

90

Corning Cable Systems

>_ 50 mm (for 2x

installation

(4x2...) over flat side)

Copper conductor

AWG 24

Electrical Characteristics (at 20°C)

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

10

16

50.3

47.3

Attenuation in dB/100m *

2.1

6.3

Typical values in dB at 100m

77.0

62.0

Typical values dB/100m

2.0

NEXT in dB at 100 m*

5.6

65.3

PSNEXT in dB at 100 m *

62.3

Typical values in dB at 100m

47.3

75.0

ELFEXT in dB at 100 m *

60.0

63.8

Typical values in dB at 100m

43.8

72.0

PSELFEXT in dB at 100 m *

60.0

60.8

Typical values in dB at 100m

40.8

70.0

ACR in dB

58.0

20

0.74 x c

4.5 ns/m

Delay skew

1

Frequency in MHz

>20 dB at 100 MHz 7 ns/100 m

31.25

62.5

100

8.0

9.0

11.4

16.5

21.3

59.0

57.0

54.0

50.0

46.0

7.2

44.2 57.0 39.7

54.0 36.7

52.0

8.0

45.8

42.8 55.0 37.8

52.0

34.8

50.0

10.1

42.9

39.9 52.0

33.9

48.0 30.9

46.0

14.4

38.4 35.4

48.0 27.9

40.0 24.9 38.0

18.2

35.3

32.3

44.0 23.8

34.0 20.8 32.0

250

29.5 –

38.5 –

36.5 –

22.1 –

20.1 –

75.0 56.4 51.8 49.0 43.9 35.6 27.8 9.0 * Standard: Requirements on 100 m of Category 5e cable for Class D cabling sections (conforms to EN 50288-2-1)

Ordering Information Type designation

Max. Outer [ Weight Length Fire Load Halogen- Tensile Category No. of Pairs (MJ/m) free Strength(N) (mm) (kg/km) (m) Order Number

F/UTP 300/24 4P

5e

F/UTP 300/24 4P

F/UTP 300/24 8P F/UTP 300/24 4P F/UTP 300/24 4P

F/UTP 300/24 8P

300

32.2 –

35.0 –

33.0 –

17.0 –

15.0 –

2.8

5e

4

0.47

Yes

82

6.1

40

1000

CCXDEE-C0047-C001-L7

5e (PVC)

4

0.41

No

82

5.8

36

1000

CCXDLE-C0047-C001-L7

5e

5e (PVC) 5e (PVC)

4

8 4

8

0.47

0.94 0.41

0.94

Yes Yes No No

82

164 82

164

6.1

40

6.2x13.5 82 5.8

36

6.2x13.5 79

*X1 cables are delivered in the Reelex box. All other cables are delivered on disposable reels.

Corning Cable Systems

305

1000 305

1000

FutureCom F FutureCom 10TEN

Propagation velocity

FutureCom E

(4x2...) over flat side)

Min. bending radius during

Unbalance to ground dB/BZL = 100 m

FutureCom D

-20 to +60°C

>_ 35 mm (for 2x

>40 dB at 1 MHz

CCXDEE-C0047-C001-X1* CCXDEE-C0087-C001-L7

CCXDLE-C0047-C001-X1* CCXDLE-C0087-C001-L7

91

FutureCom UD FutureCom UE

Unbalance to ground dB/BZL = 100 m

0 to +50°C

for one-time bending

at 10 MHz

Unbalance to ground dB/BZL = 1000 m >46 dB at 64 kHz

damp rooms

Min. bending radius

<10 m V/m

Hardware

Dry and

Operating temperature

100 V +/– 15%

Surface transfer impedance

flame retardant

Temperature range (in motion)

125 V +/– 20%

Impedance Zo at 1 - 100 MHz

Halogen-free,

Area/range of application

>5000 MV x km

Impedance Zo at 0.064 MHz

Foam-skin

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Outer jacket

1%

Insulation resistance

Industrial Cable

Largest resistance margin

PE foam skin FRNC: Halogen-free

Conductor insulation

Special Cable

PVC:

Electrical Characteristics (at 20°C)

Further Information

Mechanical Characteristics

Introduction

FutureCom™ D Cat. 5 Cable F/UTP 300/24 FRNC or PVC

FutureCom™ D Module Overview Features

Fully compatible with all modular LANscape® systems

Wide range of installation options Few individual components

High-level component density Individual shielding Halogen free

Fire class UL 94 V-0

Optimized construction for bandwidths up to 300 MHz 1500 connector cycles possible

Proven IDC technology for conductors with AWG 24 to AWG 23

Module reusable several times

Individual Components of the S100e Module

S100e Basic Module

Features

Wire management using TIA/EIA 568 A/B coding Shorter assembly times Easy handling

Compatible with FutureCom™ F/UTP and SF/UTP cables

Wire Management

92

Corning Cable Systems

FutureCom™ D S100e and S100eL Modules Introduction

Features

Easy and quick to install, no special tools required

IDC connection (IDC = Insulation Displacement Contacts) High-level component density

FutureCom F

Universal application in all modular LANscape® and

FutureCom™ components

Negligible disturbance effect from interference by means

FutureCom 10TEN

of the individual shielding of the modules Utilization of additional cable strain relief

CAXCSN-00000-C001 is possible for increased pulling

CAXDSM-00100-C001

Description

S100e Module, 1xRJ45, shielded, Cat.5 (2002),

for wire diameter AWG 24 to AWG 23

(F/UTP and SF/UTP cables), incl. copper

FutureCom D

Order Number

Unit per Delivery 1/1

FutureCom UD FutureCom UE

Ordering Information

FutureCom E

forces

conducting tape for installation in LANscape patch panels,

S100e Double Module, 2xRJ45, shielded,

Cat.5 (2002), for wire diameter AWG 24

to AWG 23 (F/UTP and SF/UTP cable),

1/1

Flex Wire Cable Telephone / for Patch Cord ISDN Products

CAXDSM-00200-C001

Hardware

outlets and floor box solutions

incl. copper conducting tape for

installation in LANscape modular patch panels, outlets and floor box solutions

for wire diameter AWG 23 to AWG 22

(PiMF cable), incl. copper conducting tape

1/1

Industrial Cable

S100eL Module, 1xRJ45, shielded, Cat.5 (2002),

for installation in LANscape

Special Cable

modular patch panels,

outlets and floor box solutions

A Class E link can be constructed in conjunction

with a S/FTP data cable and the corresponding

Further Information

CAXGSM-00100-C001

patch cords.

Corning Cable Systems

93

FutureCom™ D S100e Outlets and Patch Panel Ordering Information S100e Outlets

Order Number

Description

S100e Outlet, 2xRJ45,

Cat. 5/Cat. 5e, shielded,

Unit per Delivery

inclined, incl. mounting frame with grounding

flaps, 50x50 mm central plate with designation window, screw fixings, CAXDSD-S0201-C001

CAXDSD-S0202-C001

S100e Patch Panel Order Number

CAXDSV-02400-C001

copper conducting tape (without face plate) white, RAL 9010

1/1

pearl white, RAL 1013

1/1

Description

Unit per Delivery

S100e Patch Panel 19“,

shielded,Cat.5/Cat.5e,

including 24 FutureCom

1/1

S100e modules and

copper conducting tape, with integrated cable strain relief, 1 U,

high-grade steel front panel

Patch panel accessories please see page 156.

94

Corning Cable Systems

Order Number

CAXDSD-S0200-C001

Description

S100e Double Module Outlet,

2x RJ45, Cat. 5, inclined,

incl. mounting frame with

Unit per Delivery 1/1

FutureCom F

Ordering Information

Introduction

FutureCom™ D S100e Double Module Outlet

grounding flaps and

copper conducting tape

FutureCom 10TEN

(suitable for Rutenbeck-

compatible central plates

FutureCom D

FutureCom E

or face plates)

FutureCom UD FutureCom UE

Installation Option

S100e Double Module Outlet, 2x RJ45, Cat.5, inclined,

incl. mounting frame and copper conducting tape. CAXDSD-S0200-C001

For example, mounted with a Busch-Jaeger central plate and

Industrial Cable Further Information

Special Cable

S100e Double Module Outlet with central plate and face plate (Busch-Jaeger)

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

face plate

Corning Cable Systems

95

FutureCom™ D S100eL Outlets and Patch Panel Ordering Information S100eL Outlets

Order Number

Description

S100eL Outlet,

2xRJ45, Cat. 5/Cat. 5e,

Unit per Delivery

inclined, incl. mounting frame with grounding

flaps, 50x50 mm central plate with designation window, screw fixings,

CAXGSD-S0201-C001

CAXGSD-S0202-C001

S100eL Patch Panel Order Number

CAXGSV-02400-C001

copper conducting tape

(without face plate) white, RAL 9010

1/1

Description

Unit per Delivery

pearl white, RAL 1013

S100eL Patch Panel 19“, shielded,Cat.5/Cat.5e,

including 24 FutureCom

1/1

1/1

S100eL modules and

copper conducting tape, with integrated cable strain relief, 1 U,

high-grade steel front

panel

Patch panel accessories please see page 156. A Class E link can be constructed using S100eL patch panels and outlets, in conjunction

with a S/FTP data cable and the corresponding patch cords.

96

Corning Cable Systems

FutureCom™ D Installation Options for Outlets Option 1: “DELTAprofil” Combi-Frame, 80x80 mm, inclined,

Introduction

for three LANscape® modules, white, RAL 9010: WAXWSE-S0301-C001

equipped with two S100e modules

FutureCom F

CAXDSM-00100-C001

with one MT-RJ module adapter frame LAXLSN-00101-C001

ADP-MTRJ-CNKFL-CLS

and two blue SF/UTP flex/26 patch cords CCADNF-D2002-A030-C0

Combi-Frame “DELTAprofil”

FutureCom D

Option 2: Surface mount outlet, inclined, including

mounting frame and central plate 50x 50 mm with designation window, screw fixed, white, RAL 9010:

FutureCom UD FutureCom UE

CAXDSD-S0201-C001

equipped with one red labeling icon WAXWSE-00007-C001 one gray labeling icon

WAXWSE-00003-C001

and one red SF/UTP flex/26 patch cord CCADNF-D5002-A020-C0

combined with surface mount housing

Hardware

WAXWSE-00001-C003

and one “DELTAfläche” face plate WAXWSE-00001-C002

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Double Surface Mount Outlet

FutureCom E

FutureCom 10TEN

with one MT-RJ adapter for multimode connector

Option 3: 3-Port frame set for the assembly of three LAN-

scape fiber optic or FutureCom copper modules, inclined, including mounting frame and one triple housing with designation window and dust protection flaps and 80x80 mm face plate, white, RAL 9010:

Industrial Cable

WAXWSE-V0301-C001

equipped with two gray labeling icons WAXWSE-00003-C001

one yellow labeling icon two S100e Modules

CAXDSM-00100-C001

and two gray SF/UTP flex/26 patch cords

Frame-Set for Three Modules, inclined

Corning Cable Systems

97

Further Information

Special Cable

WAXWSE-00005-C001

FutureCom™ D Cat. 5 Patch Cords RJ45 to RJ45 Description

FutureCom D patch cords consist of Cat. 5 flex cable with

shielded RJ45 connectors at both ends. The flex cables have

four pairs and fully braided copper wire shielding. The patch cords are tested according to IEC 60332-1, Category B. They are available in various lengths and colors.

Features

SF/UTP flex cable, specified up to 300 MHz

Application-neutral due to using all four pairs Minimum surface transfer impedance (<10 mV/m at 10 MHz)

Outstanding transmission characteristics according to Channel D (2002) Cat. 5 / 5e

Ordering Information

CCAD

1

F -D

2

1

Select jacket material.

2

Select color

G = FRNC N = PVC 1 2 3 4 5 6

98

= = = = = =

gray blue yellow green red black

002 - A 3

3

- C0

Select length. 005 010 015 020 030 040 050 060 075 080 100 150

= = = = = = = = = = = =

0.5 meters 1 meter 1.5 meters 2 meters 3 meters 4 meters 5 meters 6 meters 7.5 meters 8 meters 10 meters 15 meters

Corning Cable Systems

FutureCom™ D Plug and Play™ Solutions Introduction

Application

The S100e Solution Packages are pre-terminated cable

sections with S100e modules at both ends. They are gener-

ally offered with FutureCom™ F/UTP 300/24 cables. Both

FutureCom F

modules are equipped with additional cable strain relief to allow higher pulling force during installation (the pulling

force is restricted by the cable). They enable Plug and Play™

FutureCom 10TEN

installation and therefore significantly reduce installation

time. 100% factory testing reduces failures during installa-

CCADEE-B2044-A250-C0

CCADEE-B2044-A300-C0 CCADEE-B2044-A350-C0

CCADEE-B2044-A400-C0 CCADEE-B2044-A450-C0

CCADEE-B2044-A500-C0 CCADEE-B2044-A550-C0

CCADEE-B2044-A600-C0 CCADEE-B2044-A650-C0

CCADEE-B2044-A700-C0 CCADEE-B2044-A750-C0

CCADEE-B2044-A800-C0 CCADEE-B2044-A850-C0

CCADEE-B2044-A900-C0

and additional cable strain relief

S100e Solution Package F/UTP 300/24 - 10

10 m

S100e Solution Package F/UTP 300/24 - 15

15 m

S100e Solution Package F/UTP 300/24 - 30

30 m

S100e Solution Package F/UTP 300/24 - 20 S100 Solution Package F/UTP 300/24 - 25 e

S100e Solution Package F/UTP 300/24 - 35

S100e Solution Package F/UTP 300/24 - 40 S100e Solution Package F/UTP 300/24 - 45

S100 Solution Package F/UTP 300/24 - 50 e

20 m 25 m

35 m

40 m 45 m

50 m

S100e Solution Package F/UTP 300/24 - 55

55 m

S100 Solution Package F/UTP 300/24 - 70

70 m

S100 Solution Package F/UTP 300/24 - 85

85 m

S100e Solution Package F/UTP 300/24 - 60 S100e Solution Package F/UTP 300/24 - 65 e

S100e Solution Package F/UTP 300/24 - 75

S100e Solution Package F/UTP 300/24 - 80 e

S100e Solution Package F/UTP 300/24 - 90

60 m 65 m

75 m

80 m

90 m

Hardware

CCADEE-B2044-A200-C0

with two S100e modules

Flex Wire Cable Telephone / for Patch Cord ISDN Products

CCADEE-B2044-A150-C0

data cable, 4 pairs, FRNC jacket pre-terminated

Length

Industrial Cable

CCADEE-B2044-A100-C0

Description

S100e Solution Package with F/UTP 300/24

Further Information

Order Number

Special Cable

Ordering Information

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

tion.

Corning Cable Systems

99

8.1.2. Metal Outlets

138

8.2. Accessories for Floor Box Solutions

144

8.4. Consolidation Point Housing

157

8.3. Patch Panel and Patch Panel Accessories

152

8.5. Tools and Accessories

158

162

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

8.6. 1000 RT

FutureCom F

128

FutureCom 10TEN

8.1.1. Standard Outlets

FutureCom E

8.1. Outlets and Outlet Accessories

FutureCom D

Hardware

Further Information

8

Introduction

Table of contents

Corning Cable Systems

127

Outlets and Outlet Accessories Application

The LANscape® System offers outlet solutions for all instal-

lation options and mounting methods. There are various styles available for surface, flush or raceway mounting.

Using various frame sets from the LANscape system, outlet configurations with 1 to 6 ports can be individually com-

bined. The frame sets with a central plate size of 50 x 50 mm can be combined with our “DELTAprofil” and “DELTAfläche” face plates, as well as those of other manufacturers.

Ordering Information Order Number

WAXWSM-00101-C001

WAXWSM-00108-C001

Description

Blank Cover, 1 position

for installation in modular LANscape patch panels,

outlets and floor box solutions white, RAL 9010 black, RAL 9005

Frame Sets for the Individual Configuration of Outlets Order Number

Description

Frame Set, straight,

for 2 FutureCom™ modules,

Units per Delivery

6/1

6/1

Units per Delivery

including mounting frame

WAXWSE-G0201-C001

WAXWSE-G0202-C001

128

and 50x50 mm central plate

with designation window, screw fixing white, RAL 9010

pearl white, RAL 1013

Corning Cable Systems

1/1

1/1

Outlets and Outlet Accessories

Order Number

Description

Frame Set, inclined, with grounding flap, for 2 LANscape® modules,

Units per Delivery

FutureCom F

Frame Sets for the Individual Configuration of Outlets

Introduction

Ordering Information

WAXWSE-S0202-C001

window, screw fixing white, RAL 9010

pearl white, RAL 1013

1/1

1/1

FutureCom E

WAXWSE-S0201-C001

50x50 mm central plate with designation

FutureCom 10TEN

including mounting frame and

FutureCom D

Design Line - Special Color Options

Frame Set, inclined, with grounding flap, for 2 LANscape® modules,

WAXWSE-S0203-C001

50x50 mm central plate with designation

window, screw fixing gray, RAL 7035

FutureCom UD FutureCom UE

including mounting frame and

1/1

Frame Set, inclined, with grounding

Hardware

flap, for 2 LANscape® modules, WAXWSE-S0208-C001

50x50 mm central plate with designation

window, screw fixing black, RAL 9005

Flex Wire Cable Telephone / for Patch Cord ISDN Products

including mounting frame and

1/1

Projecting Frame Set for the Individual Configuration of Outlets Description

Frame Set, inclined, projecting, for 2 LANscape modules,

Units per Delivery

Industrial Cable

Order Number

Special Cable

including mounting frame and WAXWSE-V0201-C001

WAXWSE-V0202-C001

with designation window and dust protection flaps white, RAL 9010

pearl white, RAL 1013

Further Information

50x50 mm central plate

1/1

1/1

Corning Cable Systems

129

Outlets and Outlet Accessories Ordering Information

Frame Set, inclined, projecting, 3- or 6-Port Outlet Order Number

Description

Frame Set, inclined, projecting, for 3 LANscape® modules,

Units per Delivery

including mounting frame and triple housing

with designation window, WAXWSE-V0301-C001

WAXWSE-V0302-C001

dust protection flaps

and face plate 80x80 mm white, RAL 9010

1/1

pearl white, RAL 1013

1/1

Frame Set, inclined, projecting, for 6 LANscape modules,

including mounting frame and two triple housings

with designation window,

WAXWSE-V0601-C001

WAXWSE-V0602-C001

dust protection flaps and face plate 151x80 mm white, RAL 9010

1/1

pearl white, RAL 1013

1/1

Installation Option: 6-Port Frame Set for the mounting of 6

LANscape modules, inclined, including mounting frame and

two triple housings with designation window and dust protection flaps and face plate 151 x 80 mm, white, RAL 9010; WAXWSE-V0601-C001

equipped with two S250 modules CAXESM-00100-C001

two black labeling icons WAXWSE-00008-C001

four blue labeling icons WAXWSE-00004-C001

and two blue S/FTP/flex patch cables Outlet for 6 modules, Inclined

130

CCAEGB-G2002-A030-C0

Corning Cable Systems

Outlets and Outlet Accessories

Introduction

Labeling Icons and Designation Labels

All frame sets with a 50x50 mm central plate as well as the

3- and 6-port frame sets offer the opportunity to code each

port with labeling icons. The icons indicate port applications

FutureCom F

and show a telephone or a computer (LAN operation). They are available in six different colors. Furthermore, these

frame sets have a designation window with a clear cover, for

WAXWSE-00007-C001

WAXWSE-00008-C001

WAXWSE-00001-C009

Labeling Icon, computer/telephone, yellow, RAL 1021

Labeling Icon, computer/telephone, green, RAL 6029

Labeling Icon, computer/telephone, red, RAL 3000

120/1 120/1

120/1

DIN A4 Title Strip Sheet,

10/1

with 150 designation labels

for LANscape® outlets, white,

FutureCom E

120/1

Labeling Icon, computer/telephone, black, RAL 9005

FutureCom D

blue, RAL 5015

120/1

FutureCom UD FutureCom UE

WAXWSE-00006-C001

120/1

gray, RAL 7042

Hardware

WAXWSE-00005-C001

Labeling Icon, computer/telephone,

Labeling Icon, computer/telephone,

e.g. for labeling using a PC-printer

Industrial Cable

WAXWSE-00004-C001

Units per Delivery

Special Cable

WAXWSE-00003-C001

Description

Further Information

Order Number

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Ordering Information

FutureCom 10TEN

inserting a designation label.

Corning Cable Systems

131

Outlets and Outlet Accessories Ordering Information

Face Plates for 50 x 50 mm Central Plates Order Number

WAXWSE-00001-C001

WAXWSE-00002-C001

Description

“DELTAprofil” Face Plate, 80x80 mm, for LANscape® outlets with

50x 50 mm central plate white, RAL 9010

pearl white, RAL 1013

Units per Delivery 1/1

1/1

“DELTAfläche” Face Plate, 75x75 mm, WAXWSE-00001-C002

WAXWSE-00002-C002

for LANscape outlets with

50x 50 mm central plate white, RAL 9010

pearl white, RAL 1013

Surface Mount Housing for “DELTAfläche” Outlets Order Number

WAXWSE-00001-C003

WAXWSE-00002-C003

132

Description

“DELTAfläche” Surface Mount Housing, for the individual configuration of

LANscape outlets, 75x75 mm white, RAL 9010

pearl white, RAL 1013

Corning Cable Systems

1/1

1/1

Units per Delivery 1/1

1/1

Outlets and Outlet Accessories

WAXWSE-S0301-C001

Units per Delivery

white, RAL 9010

1/1

“DELTAprofil” Combi-Frame, 80x80 mm, inclined, for 3 LANscape® modules pearl white, RAL 1013

1/1

Installation Options

1/1

1/1

FutureCom UD FutureCom UE

pearl white, RAL 1013

Hardware

Option 1: “DELTAprofil” Combi-Frame, 80x80 mm, inclined , white, RAL 9010;

WAXWSE-S0301-C001

equipped with two S250 Modules, CAXESM-00100-C001

and one LC Duplex Module for multimode connectors LAXLSM-00101-C007

Option 2: “DELTAfläche” Combi-Frame, 75x75 mm,

Industrial Cable

“DELTAprofil”Combi-Frame

inclined , white, RAL 9010;

WAXWSE-S0301-C002

equipped with two S100e Modules, CAXDSM-00100-C001

and one single MT-RJ Module for single-mode/multimode “DELTAprofil” Combi-Frame

connectors

LAXLSM-00101-C004

Corning Cable Systems

Flex Wire Cable Telephone / for Patch Cord ISDN Products

white, RAL 9010

Special Cable

WAXWSE-S0302-C002

inclined, for 3 LANscape modules

133

Further Information

WAXWSE-S0301-C002

“DELTAfläche” Combi-Frame, 75x75 mm,

FutureCom D

FutureCom E

WAXWSE-S0302-C001

Description

FutureCom F

Order Number

FutureCom 10TEN

Combi-Frames

Introduction

Ordering Information

Outlets and Outlet Accessories Brackets for Raceway Mounting

The following brackets can be used for the quick and simple installation of outlets and frame sets in raceways.

They support the minimum bend radius requirements for

copper and fiber optic cables. In order to separate network

components from power systems, the brackets are supplied with a removable half-shell partition, which can be optionally inserted.

An additional advantage of the half-shell partition is the

protection of fiber optic connections against mechanical damage during pulling of new cables. The brackets are

suitable for Tehalit and Ackermann raceways with T-groove mounting.

Ordering Information Order Number

WAXWSE-00001-C010

Description

Brackets for Raceway Mounting of outlets and frame sets, T-groove mounting,

height 50 mm, with half-shell partition,

Units per Delivery 1/1

white, RAL 9010

WAXWSE-00008-C002

Brackets for Raceway Mounting of outlets and frame sets, T-groove mounting,

height 55 mm, with half-shell partition, black, RAL 9005

134

Corning Cable Systems

1/1

Description

WAXWSE-00001-C008

Surface Mount Housing, 67x110 mm,

WAXWSE-V0201-C004

Combi-Frame, 67x110 mm,

for combi-frame (67x110 mm),

1/1

for installation of two

single LANscape® modules,

FutureCom E

FutureCom 10TEN

white, RAL 9010

Units per Delivery

1/1

FutureCom D

Order Number

FutureCom F

Ordering Information

Introduction

Outlets and Outlet Accessories

inclined,

CAXCSE-G0201-C001

Combi-Frame, 45x45 mm,

with self-closing shutters for

the installation of 2 FutureCom™

FutureCom UD FutureCom UE

white, RAL 9010

1/1

Hardware

modules, straight,

Combi-Frame for VanGeel Columns,

45x45 mm, with self-closing shutters for the installation of 2 FutureCom

Units per Delivery 1/1

modules, straight, white, RAL 9010

Special Cable

CAXCSE-G0201-C002

Description

Further Information

Order Number

Industrial Cable

Combi-Frames for VanGeel Columns

Flex Wire Cable Telephone / for Patch Cord ISDN Products

white, RAL 9010

Corning Cable Systems

135

Outlets and Outlet Accessories Ordering Information Order Number

WAXWSE-00001-C004

Description

Surface Mount Housing, 87x87 mm, including two screws for face plate (87x87 mm),

Units per Delivery 1/1

white, RAL 9010

WAXWSE-00001-C005

Face plate, 87x87 mm,

for one module housing,

including two metric screws

1/1

and two whitworth screws,

for face plate mounting in installation outlets, white, RAL 9010

WAXWSE-00001-C006

Surface Mount Housing, 87x147 mm, including two screws for face plate (87x147 mm),

1/1

white, RAL 9010

WAXWSE-00001-C007

Face Plate, 87x147 mm,

for two module housings, including two metric

screws and two whitworth screws,

for face plate mounting in installation outlets, white, RAL 9010

136

Corning Cable Systems

1/1

Order Number

CAXCSE-V0201-C001

Description

Module Housings with

self-closing shutters, projecting, inclined, for face plates

Units per Delivery 1/1

FutureCom F

Ordering Information

Introduction

Outlets and Outlet Accessories

(147x87 mm and 87x87 mm)

FutureCom 10TEN

for the installation of 2 FutureCom™

Universal Module Housing, projecting, inclined,

for face plates (147x87 mm and

1/1

FutureCom D

WAXWSE-V0201-C002

FutureCom E

modules, white, RAL 9010

87x87 mm) for the installation of 2 FutureCom™ modules,

FutureCom UD FutureCom UE

central partition provided, white, RAL 9010

Surface Combi-Frame Set, 75x65 mm, with self-closing shutters for the

installation of 2 FutureCom modules,

1/1

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

straight, white, RAL 9010

Further Information

CAXCSE-U0201-C001

Corning Cable Systems

137

Metal Outlets for Industrial Applications Application

The 2-port LANscape® industrial metal outlets with

integrated cable strain relief can be equipped with any LANscape fiber optic or copper modules. The outlet is

suitable for harsh environmental conditions and can be

mounted on a surface, as well as in different configurations (see page 139) on top hat rails (35 mm DIN rails).

Features

Integrated cable strain relief for two individual cables (separate assembly possible)

Metal construction suitable for harsh environmental conditions in industrial surroundings

Conductive housing for shielded FutureCom™ modules Non-detachable designation label

Cable entry with brush strip provides dust protection regardless of cable diameter

Non-detachable housing fastening screw

Horizontal and vertical top hat rail mounting

Excess length storage for fiber without exceeding minimum bending radius

Retrofitting and re-equipping possible without complete disassembly (2-piece housing)

Ordering Information Order Number

WAXWSD-V0208-C001

Description

2-Port Metal Outlet

for Industrial Applications, 60x65x121 mm (HxWxD),

Unit per Delivery 1/1

for the installation

of 2 LANscape modules, inclined, projecting,

with designation window, metal construction with

integrated cable strain relief, anthracite, RAL 7016 *

* Other colors upon request

138

Corning Cable Systems

Metal Outlets for Industrial Applications

often have different distances between the top hat rails and the cabling conduits. In addition, there are two diagonally positioned drilled holes in the back of the outlet housing, so that the metal outlet can be mounted directly on the surface by removing the top hat rail clip.

Installation Option

2-port Metal Outlets for Industrial Applications, 60 x 65 x 121 mm (HxWxD), for the installation of two LANscape® modules,

inclined, with designation window, metal construction with integrated cable strain relief, anthracite, RAL 7016; WAXWSD-V0208-C001

equipped with one S1200 Module, Cat. 7

CAXFSM-00100-C001

in one S1200 Module Adapter CAXFSN-00110-C001

Assembled with S/STP1200 FutureCom™ cable

CCXFCB-L0047-C001-L7

and with one MT-RJ Module LAXLSM-00101-C004

and one MT-RJ UniCam® Connector 92-051-97-P-E

assembled with protected

MiniZip FO industrial cable

Special Cable

J-VH(2ZN)H 2X1G50/125

Further Information

(Left side) Closed metal outlets (Right side) Basic housing with mounted copper and fiber optic cables

Corning Cable Systems

FutureCom D

The top hat rail clips can be assembled in four different positions, since distributor cabinets (e.g. robot or machine controls)

FutureCom UD FutureCom UE

Vertical top hat rail: Middle top hat rail clip, rotated 90°

Hardware

Horizontal top hat rail: Lower top hat rail clip

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Horizontal top hat rail: Middle top hat rail clip

Industrial Cable

Horizontal top hat rail: Upper top hat rail clip

FutureCom E

FutureCom 10TEN

FutureCom F

Introduction

Mounting on a Top Hat Rail (35 mm DIN rails) / On a Surface

139

4-Port Metal Outlets for Industrial Applications Application

The 4-port LANscape® industrial metal outlets with

integrated cable strain relief can be equipped with any LANscape fiber optic or copper modules. The outlet is

suitable for harsh environmental conditions and can be

mounted on a surface, as well as on a top hat rail (35 mm DIN rails).

Features

Integrated cable strain relief for 4 individual cables (separate mounting is possible)

Metal construction suitable for harsh environmental conditions in industrial surroundings

Conductive housing for shielded FutureCom™ modules Non-detachable designation label

Cable diameter-independent and dust-protected cable entry

Integrated grounding pin

Non-detachable housing fastening screw

Horizontal and vertical top hat rail mounting is possible Splice holder for 12 crimp-splice connections including

excess length storage for FO pigtails and cables, can be retrofitted at any time

Retrofitting and re-equipping without complete disassembly due to the two-part housing

Ordering Information Order Number

WAXWSD-V0408-C001

Description

4-Port Metal Outlet

for Industrial Applications, 79x101x121 mm (HxWxD),

Unit per Delivery 1/1

for the installation of

max. 4 LANscape modules, inclined, with designation

window, metal construction with integrated cable strain relief, integrated grounding

pin, easy retrofitting of the optional splice tray,

WAXLSD-0000-C001,

anthracite, RAL 7016 *

* other colors upon request

140

Corning Cable Systems

4-Port Metal Outlets for Industrial Applications

Introduction

Installation Option

4-port Metal Outlet for Industrial Applications, 79 x 101 x 121 mm (HxWxD), for the

FutureCom F

installation of max. 4 LANscape® mo-

dules, inclined, with designation window, metal construction with integrated cable WAXWSD-V0408-C001

CAXFSM-00100-C001 one a S1200 module

CAXFSN-00110-C001

Closed metal outlet

Basic housing with mounted copper cables

Basic housing with mounted copper and FO cables incl. splice tray

Splice tray (rear side) with mounted splice connections

one S250 module, Cat. 6 CAXESM-00100-C001

FutureCom UD FutureCom UE

and with one SC duplex module LAXLSM-00201-C001

with dust protection flap for SC duplex multimode connector, beige LAXLOK-00013-C001

equipped with splice tray WAXLSD-00000-C001

incl. two stored crimp-splice .... mounted on a top hat rail

Ordering Information

Splice Tray for 4-Port Metal Outlets, 15x96x92 mm (HxWxD),

with splice organizer for

Units per Delivery 1/1

12 crimp-splice connections,

separate excess length storage which support the minimum

Special Cable

WAXLSD-00000-C001

Description

bend radius requirements

for fiber optic pigtails and cables,

anthracite, RAL 7016 *

Further Information

Order Number

Industrial Cable

connections of two SC pigtails

* other colors upon request

Corning Cable Systems

Hardware

Cat.7

Flex Wire Cable Telephone / for Patch Cord ISDN Products

equipped with one S1200 module,

FutureCom D

anthracite, RAL 7016;

FutureCom E

FutureCom 10TEN

strain relief, integrated grounding pin,

141

4-Port Metal Outlets for Industrial Applications with Security Features Description

Features

The LANscape® metal outlet is constructed entirely from

metal and is intended for wall surface mounting or

mounting in false floors. It offers space for four LANscape® fiber optic or copper modules. The outlet is especially designed for security applications.

Metal construction suitable for harsh environmental conditions

Cable strain relief for individual cables at cable entry in the basic housing using cable ties

Connection protection and security against accidental or unauthorized access

Fastening of the housing cover using a central screw, which can be protected, e.g. using a security label

Excess length storage for fiber optic cable, maintaining the minimum bending radius

Basic housing designed to be conductive

(important when using FutureCom™ copper modules)

Basic housing with mounted copper and FO cable

Closed metal outlet with mounted copper and FO cables

Ordering Information Order Number

WAXWSD-U0407-C001

Description

Metal Outlet, 4-Port

45x93x143.5 mm (HxWxD), for the installation of 4

Standard fastening shape (60 mm hole spacing) Horizontal and vertical top hat rail mounting

Unit per Delivery 1/1

LANscape individual

modules, straight, metal construction with

integrated strain relief, patchcord protection

and excess length storage for FO cables, WAXWSD-U0408-C001

red, RAL 3000 *

Metal Outlet, 4-Port

45x93x143.5 mm (HxWxD), for the installation of 4

1/1

LANscape individual

modules, straight, metal construction with

integrated strain relief, patchcord protection

and excess length storage for FO cables,

anthracite, RAL 7016 *

* other colors upon request

142

Corning Cable Systems

Features

The LANscape® metal outlet is constructed entirely from

Metal construction, suitable for harsh environmental

metal and is intended for wall surface mounting, raceway

conditions

mounting or mounting in false floors. It offers space for

Cable strain relief for individual cables in the basic housing using cable ties

FutureCom F

four four LANscape fiber optic or copper modules.

Fastening of the housing cover using a central screw Excess length storage for FO cables of max. length

0.6-1.0 m, for maintaining the minimum bending radius Basic housing designed to be conductive (important when using copper modules)

Standard fastening shape (60 mm hole spacing)

FutureCom D

FutureCom E

Horizontal and vertical top hat rail mounting

WAXWSD-U0407-C002

Description

Metal Outlet, 4-Port

45x93x87 mm (HxWxD), for the installation of 4

Unit per Delivery 1/1

Hardware

Order Number

FutureCom UD FutureCom UE

Closed metal outlets with mounted copper cables

Ordering Information

LANscape individual modules, straight,

Flex Wire Cable Telephone / for Patch Cord ISDN Products

metal construction with

integrated strain relief and excess length storage for FO cables,

red, RAL 3000 *

45x93x87 mm (HxWxD), for the installation of 4

1/1

Industrial Cable

Metal Outlet, 4-Port

LANscape individual modules, straight,

Special Cable

metal construction

with integrated strain

relief and excess length storage for FO cables,

Further Information

WAXWSD-U0401-C002

FutureCom 10TEN

Description

Introduction

4-Port Metal Outlets for Industrial Applications

white, RAL 9010 *

* Other colors upon request

Corning Cable Systems

143

Accessories for Floor Box Solutions Applications

The LANscape® mounting panels for floor boxes are suitable

for all fiber optic and copper modules.

Description

The modular system provides floor box solutions up to nine ports for floor boxes manufactured by Ackermann,

Kleinhuis, Electraplan, VanGeel, OBO Bettermann and Vergokan.

The cable strain relief is fixable in three different positions. Self-adhesive designation strips are available for all ports.

Splicing of pigtails is possible in the floor box in combination with the protection box and a special splice tray.

Features

Suitable for all LANscape fiber optic or copper modules

Mounting in the Ackermann GES4 Floor Box

Installation Option

Robust metal construction, black

No additional mounting inserts required

Integrated individual strain relief of each cable (regardless of the diamter)

Strain relief mountable in various positions No screws necessary

Integrated grounding pin Designation windows

Up-gradeable with protection box for fiber optic cabling Up-gradeable with special splice trays

Mounting panel for Ackermann floor boxes GES 2, GES 4, GES 4/10, GESR 4, GES 6, GES 6/10, GESR 7/10 (outer mounting position only) or GES 8/10; WAXWSU-00600-C003

The two installation positions (3 modules each) are equipped with:

three S250 modules

CAXESM-00100-C001

one SC duplex module LAXLSM-00208-C001 and one blank cover

WAXWSM-00108-C001

144

Corning Cable Systems

Mounting Panels for Ackermann Floor Boxes Order Number

WAXWSU-00600-C003

Description

Mounting Panel for Ackermann

Floor Boxes GES 2, GES 4, GES 4/10, GESR 4, GES 6, GES 6/10, GESR 7/10

Units per Delivery 1/1

FutureCom F

Ordering Information

Introduction

Accessories for Floor Box Solutions

FutureCom 10TEN

(outer mounting position only)

or GES 8/10, for the installation of

6 LANscape modules, with integrated strain relief and six cable ties,

Mounting Panel for Ackerman Floor Boxes GESR 7/10 (middle

mounting position only), GES 9

1/1

FutureCom D

WAXWSU-00900-C003

FutureCom E

designation window, metal, black

or GESR 9, for the installation of

FutureCom UD FutureCom UE

9 LANscape modules, with integrated strain relief and nine cable ties,

Mounting Panel for VanGeel Floor Box (IK-1 long), for the installation of 9 LANscape modules, with

Units per Delivery 1/1

integrated cable strain relief and nine cable ties,

Industrial Cable

designation window, metal, black

Special Cable

WAXWSU-00900-C005

Description

Further Information

Order Number

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Mounting Panels for VanGeel Floor Boxes

Hardware

designation window, metal, black

Corning Cable Systems

145

Accessories for Floor Box Solutions Ordering Information

Mounting Panels for Kleinhuis Floor Boxes Order Number

WAXWSU-00900-C002

Description

Mounting Panel for Kleinhuis Floor Box GR. II or GR. III

(outer mounting position

Units per Delivery 1/1

only in the round box),

for the installation of 9 LANscape® modules, with integrated cable

strain relief and nine cable ties,

designation window, metal, black

Mounting Panels for Electraplan Floor Boxes Order Number

WAXWSU-00900-C004

Description

Mounting Panel for Electraplan Floor Box KDR Q3 and KDR R3 (left, center, right), for the

Units per Delivery 1/1

installation of 9 LANscape modules, with integrated cable strain relief and nine cable ties,

designation window, metal, black

Mounting Panels for Vergokan Floor Boxes

Order Number

WAXWSU-00900-C006

Description

Mounting Panel for Vergokan

Floor Box KDSVV (left, center, right), for the installation of 9 LANscape modules, with integrated cable

strain relief and nine cable ties,

designation window, metal, black

146

Corning Cable Systems

Units per Delivery 1/1

Mounting Panels for OBO Bettermann Floor Boxes Order Number

WAXWSU-00900-C007

Description

Mounting Panel for OBO Bettermann Floor Boxes GE 12 R/5,GE 12R/10,

GE 12 RK/5,GE 12RK/10, (left, center,

Units per Delivery 1/1

FutureCom F

Ordering Information

Introduction

Accessories for Floor Box Solutions

FutureCom 10TEN

right), for the installation of 9 LANscape® modules, with

integrated cable strain relief and nine cable ties,

Order Number

WAXWSU-00000-C003

Description

Protection Box for Ackermann Floor Boxes (GES 2, GES 4,

GES 4/10, GESR4, GES 6, GES 6/10,

FutureCom D

Units per Delivery

FutureCom UD FutureCom UE

Protection Boxes for Mounting Panels

FutureCom E

designation window, metal, black

1/1

GESR 7/10 (only outer mounting

position) or GES 8/10, with integrated

Floor Boxes GESR 7/10 (only center

position), GES 9 or GESR 9, Kleinhuis

1/1

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Protection Box for Ackermann

Gr. II or Gr. III (only outer mounting

position in round boxes), Elektroplan KDR Q3 or KDR R3 (left, center, right), VanGeel (IK-1 long), Vergokan KDSVV

(left, center, right) and OBO Bettermann

Industrial Cable

GE12 R1S, GE 12 R/10, GE 12 RK/5 or GE 12 RK/10 (left, center, right),

with integrated cable management,

Special Cable

metal, black

Further Information

WAXWSU-00000-C004

Hardware

cable management, metal, black

Corning Cable Systems

147

Accessories for Floor Box Solutions Ordering Information

Protection Boxes for Mounting Panels Order Number

WAXLSU-00000-C005

Description

Splice Tray for Protection Box WAXWSU-00000-C003

(Ackermann GES 2, GES 4, GES 4/10,

Units per Delivery 1/1

GESR 4, GES 6, GES 6/10, GESR 7/10, outer mounting position only, or

GES 8/10), with splice organizer for the storage of 12 crimp-splice protectors, metal, black WAXLSU-00000-C006

Splice Tray for Protection Box

WAXWSU-00000-C004 for Ackermann

Floor Boxes GESR 7/10 (only center position),

1/1

GES 9 or GESR 9, Kleinhuis Gr. II or Gr. III

(only outer mounting position in round boxes), Elektroplan KDR Q3 or KDR R3

(left, center, right), VanGeel (IK-1 long),

Vergokan KDSVV (left, center, right) and OBO Bettermann GE12 R1S, GE 12 R/10,

GE 12 RK/5 or GE 12 RK/10 (left, center, right),

with splice organizer for the storage of 12 crimp-splice protectors, metal, black

Mounting Panels for Ackermann Floor Boxes Features

Suitable for all LANscape fiber optic or copper modules Metal construction, high-grade steel

No mounting insert required Order Number

WAXWSU-00100-C001

Description

Mounting Panel for Ackermann Floor Boxes GESR 2, for the

installation of one LANscape

module, with grounding flap, metal, high-grade steel

148

Corning Cable Systems

Units per Delivery 1/1

Accessories for Floor Box Solutions

Mounting Panel for Ackermann Floor BoxGES 2,GES 4, GES 4/10,

GESR 4, GES 6, Ges6/10, GES7/10

Units per Delivery

FutureCom F

WAXWSU-00600-C004

Description

1/1

(outside) or GES 8/10 for the

installation of 6 LANscape® modules,

Mounting Panel for Ackermann

Floor Box GESR 7/10 (center), GES 9, or GESR 9, for the installation of

1/1

FutureCom D

WAXWSU-00900-C001

FutureCom E

high-grade steel

9 LANscape modules,

FutureCom UD FutureCom UE

high-grade steel

Hardware

Installation Option

Mounting panel for Ackermann floor box GESR 2

Flex Wire Cable Telephone / for Patch Cord ISDN Products

WAXWSU-00100-C001

equipped with one S1200 module CAXFSM-00100-C001

in conjunction with an adapter frame

Industrial Cable

CAXFSN-00110-C001

Further Information

Mounting in the Ackermann Floor Box GESR 2

Special Cable

Order Number

FutureCom 10TEN

Mounting Panels for Ackermann Floor Boxes

Introduction

Ordering Information

Corning Cable Systems

149

Accessories for Floor Box Solutions Features

Suitable for all LANscape® modules in conjunction with universal module housings (WAXWSE-V0201-C002) Robust metal construction

No mounting insert required Integrated cable strain relief

Rapid installation by snapping the module housings into the mounting panel No screws required

Ordering Information Order Number

WAXWSU-00400-C001

Description

Mounting Panel for Ackermann

Floor Boxes GES 2, GES 4, GES 4/10, GESR 4, GES 6, GES 6/10, GESR 7/10

Units per Delivery 1/1

(only center position) or GES 8/10

for the installation of 2 LANscape

housings (WAXWSE-V0201-C002 or CAXCSE-V0201-C001), high-grade steel

WAXWSU-00600-C001

Mounting Panel for Ackermann Floor Boxes GESR 7/10 (center),

GES 9, or GESR 9, for the installation

1/1

of 3 LANscape Housings

(WAXWSE-V0201-C002 or CAXCSE-V0201-C001), high-grade steel

WAXWSU-00600-C002

Mounting Panel for Kleinhuis

Floor Box GR.II and GR.III (outside mounting position in round box),

for the installation of 3 LANscape Housings (WAXWSE-V0201-C002 or CAXCSE-V0201-C001), high-grade steel

150

Corning Cable Systems

1/1

Accessories for Floor Box Solutions

WAXWSU-00000-C001

Description

Blank Cover Panel for unused mounting positions, suitable

for Ackermann and Kleinhuis

Delivery

FutureCom F

Order Number

1/1

FutureCom 10TEN

Blank Cover Panel

Introduction

Ordering Information

mounting panels (page 150),

FutureCom D

FutureCom E

metal, high-grade steel

Installation Options

FutureCom UD FutureCom UE

Mounting panel in the Kleinhuis floor box GR. III WAXWSU-00600-C002

The three installation positions are configured as follows: 1. Blank Cover

WAXWSU-00000-C001 CAXCSE-V0201-C001

equipped with two S100eL modules

CAXGSM-00100-C001

and one green S/FTP flex/26 patch cord CCAEGB-G4002-A030-C0

Mounting in the Kleinhuis Floor Box GR. III

3. Universal Housing

WAXWSE-V0201-C002

Industrial Cable

equipped with one S100eL module

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

2. Module housings with self-closing shutters

CAXGSM-00100-C001

and one gray S/FTP flex/26 patch cord CCAEGB-G1002-A020-C0

Special Cable

and one MT-RJ fiber optic module

Further Information

LAXLSM-00101-C004

Corning Cable Systems

151

Patch Panels and Patch Panel Accessories Ordering Information Order Number

WAXWSV-02400-C001

Description

19“ Patch Panel,

for max. 24 LANscape®

fiber optic or FutureCom™

Units per Delivery 1/1

copper modules, with

integrated cable strain relief, 1 U,

high-grade steel

WAXWSV-02400-C002

19“ Patch Panel,

for max. 24 LANscape

fiber optic or FutureCom

1/1

copper modules, 1 U,

high-grade steel

WAXWSV-01200-C001

10“ Patch Panel,

for max. 12 LANscape

fiber optic or FutureCom

1/1

copper modules, with

integrated cable strain

relief, 1 U,

high-grade steel

WAXWSV-04800-C001

19“ Patch Panel,

for max. 48 LANscape

fiber optic or FutureCom

1/1

copper modules, with

integrated cable strain

relief, 3 U,

high-grade steel

152

Corning Cable Systems

Ordering Information

Units per Delivery

Description

19“ Blank Panel,

to fill unused areas

FutureCom F

Order Number

Introduction

Patch Panels and Patch Panel Accessories

WAXWSW-00000-C007

2U

1/1

19“ Cable Management

1/1

Panel, 1 U, high-grade steel front panel with 5 black

FutureCom E

1/1

FutureCom D

WAXWSW-00000-C005

1U

FutureCom UD FutureCom UE

WAXWSW-00000-C004

or rack,

high-grade steel

FutureCom 10TEN

in the distribution cabinet

cable management

19“ Cable Feedthough

Panel, for feeding the

cables into the cabinet

1/1

interior or rack, incl. edge grommeting, high-grade

Special Cable

Industrial Cable

steel front panel

Further Information

WAXWSW-00000-C008

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

brackets

Corning Cable Systems

153

Patch Panels and Patch Panel Accessories Ordering Information Order Number

WAXWSV-02408-C001

Description

19“ Patch Panel,

for max. 24 LANscape®

fiber optic or FutureCom™

Units per Delivery 1/1

copper modules, with

integrated cable strain relief, 1 U, black

WAXWSV-02408-C002

19“ Patch Panel,

for max. 24 LANscape

fiber optic or FutureCom

1/1

copper modules, 1 U,

black

154

Corning Cable Systems

Order Number

Description

19“ Blank Panel,

to fill unused areas

Units per Delivery

FutureCom F

Ordering Information

Introduction

Patch Panels and Patch Panel Accessories

WAXWSW-00008-C007

2U

1/1

19“ Cable Management

1/1

Panel,1 U, black

front panel with 5 black

FutureCom E

1/1

FutureCom D

WAXWSW-00008-C005

1U

FutureCom UD FutureCom UE

WAXWSW-00008-C004

cabinet or rack,

black

FutureCom 10TEN

in the distribution

cable management

19“ Cable Feedthough

Panel, for feeding the

cables into the cabinet

1/1

interior or rack, incl. edge grommeting, black

Special Cable

Industrial Cable

front panel

Further Information

WAXWSW-00008-C008

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

brackets

Corning Cable Systems

155

Patch Panels and Patch Panel Accessories Ordering Information

Designation Labels for Patch Panels Order Number

Description

Delivery

WAXWSW-00000-C002

440 mm Designation Window,

1/1

WAXWSW-00000-C003

DIN A4 Designation Label Sheet,

1/1

Description

Units per Delivery

Dust Protection Plug Order Number TKE:1304010

156

self-adhesive for LANscape® patch panels

with 20 title strips

for LANscape patch panels, white

Dust Protection Plug for RJ45 Modules, gray

Corning Cable Systems

1/100

Consolidation Point Housings for LANscape® Modules

Introduction

Features

Full metal housing for up to 12 LANscape® fiber optic

or copper modules

Conforms to standards ISO/IEC 11801 (2002) and

FutureCom F

EN 50173-1 (2003)

Ideally suited for a distribution or consolidation point Suitable for ceiling, wall, false floor or desk mounting

FutureCom 10TEN

Individual strain relief for incoming and outgoing cables Dust-proof feedthrough for incoming cables

Easy plug-in of consolidation point cables (dust protection and mechanical protection)

FutureCom E

Housing floor electrically conductive for optimal shielding transition or grounding Installation height of 60 mm

FutureCom D

Fastening of the housing top with non-detachable screws

Consolidation Point Housing for max.

12 LANscape modules,

Units per Delivery 1/1

with cable strain relief for incoming data

Flex Wire Cable Telephone / for Patch Cord ISDN Products

cable, patch cord strain

relief and dust protection flap for floor, wall and ceiling mounting,

60 x 263 x 320 mm

Industrial Cable

(HxWxD)

Special Cable

WAXWSW-00008-C015

Description

Further Information

Order Number

Hardware

Ordering Information

FutureCom UD FutureCom UE

Black sheet steel housing top, RAL 9005, white labeling

Corning Cable Systems

157

Tools and Accessories Description

The installation of FutureCom™ modules is even easier and quicker with special tools. These high-quality tools are available together in a practical toolkit, as well as

individually. The use of parallel pliers to terminate the

IDC-contacts of the FutureCom F S1200 modules is strongly recommended (see page 160).

Ordering Information Order Number

CAXCSN-00000-C005

Description

Assembly Toolkit for FutureCom Modules

1

4

5 13

158

Units per Delivery 1/1

2

6

7

8

3

9

14

Corning Cable Systems

10

11

12

15

Application

Assembly of additional cable strain relief for S100e, S100eL and S250 Modules

2. Module Tool

Assembly of the basic modules with wire management for S10TEN, S100e, S100eL and S250 Modules

3. S1200 Installation Tool

Tool for stripping cable, trimming PiMF foil and preparing the pairs of S1200

5. Screwdriver for Cross Slotted Screws, Size 1

Universal

7. Electronics Edge-Cutter, 125 mm 8. Waterproof Pen, white 9. Waterproof Pen, black

10. Telephone Scissors, 130 mm

11. Open-Ended Wrench, size 8 x 10 12. Tape Measure, 1.4 m long

13. Copper Conducting Tape, 12.7 mm wide, 16.5 m

14. Steel Ruler, 300 mm long

Universal Universal Marking Marking

Universal

Hexagon head bolts/nuts, size 8 x 10 Universal

Module installation (terminating braid shield) Universal

Cutting cable sheath

15. “Jokari” Stripping Knife

Special Cable

16.5 m

1/1

Industrial Cable

Copper Conducting Tape, 12.7 mm wide,

Units per Delivery

Further Information

CAXCSN-00000-C004

Description

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Ordering Information

Hardware

Assembly of S1200/S250/S250fx/U250/U250fx/S100eL/S100e/U100e Modules

16. Installation Instructions

Order Number

FutureCom E

6. Edge-cutter

Universal

FutureCom D

4. Screwdriver for Slotted Screws, Size 4

modules or connectors

FutureCom F

1. Crimping Tool

FutureCom 10TEN

Description

FutureCom UD FutureCom UE

Assembly Toolkit Contents

Introduction

Tools and Accessories

Corning Cable Systems

159

Tools and Accessories Ordering Information

Parallel Pliers for S1200 Module Assembly Order Number

CAXCSN-00000-C008

S1200 Assembly Tool CAXFSN-00000-C001

160

Description

Comfort Wide-Jawed Parallel Pliers, for terminating IDC contacts on FutureCom™ S1200 Modules

S1200 Assembly Tool, for S1200 modules and S1200/4- or S1200/2 connectors

Corning Cable Systems

Units per Delivery 1/1

1/1

Tools and Accessories

CAXCSN-00000-C007

Description

Assembly Tool, for connecting

the basic modules

Units per Delivery

FutureCom F

Order Number

1/1

FutureCom 10TEN

Assembly Tool for Modules

Introduction

Ordering Information

with the wire

management for

FutureCom™ S10TEN,

FutureCom E

S10TEN fx, S250, S250fx,

U250, U250fx, S100eL,

Crimping Pliers for die assembly

of the additional cable strain relief for the FutureCom™ S10TEN,S10TEN fx,

Units per Delivery 1/1

Flex Wire Cable Telephone / for Patch Cord ISDN Products

S250, S250fx, U250, U250fx, S100eL,

Industrial Cable

S100e, U100e modules

Special Cable

CAXCSN-00000-C002

Description

Further Information

Order Number

Hardware

Crimping Pliers for Additional Strain Relief

FutureCom UD FutureCom UE

FutureCom D

S100e, U100e modules

Corning Cable Systems

161

IDC Terminal Strips 1000 RT Description

Corning Cable Systems IDC terminal strips provide a reliable

Features

and effective wire connection for telecommunications and

data networks at very high density. Our strips can be mounted in 19“ panels or IDC blocks, for direct connectorization,

with punch down tool. The IDC terminal strips offer a very high density with a height of only 13.8 mm including wire

guides. They are easy to install and maintain. Userfriendly

cable management supports longterm control over changing jumpering.

High density

User-friendly cable managment through wire guides High felxibility due to adaptability of different wire guides

Multiple access wire guiding of incoming wires

(e.g. system cable to be terminated on upper row of IDC

contacts) is possible from either rear or left or right hand side.

Multiple access wire guiding of outgoing wires (to be terminated on lower row of IDC contacts) is possible from either left or right hand side

All combinations possible and available on request Suitable for conductor size AWG 22-28

Ordering Information

IDC Disconnection Terminal Strips Order Number

C39104-A123-A10 C39104-A123-A11

C39104-A123-A12 C39104-A123-A13

Description

Units per Delivery

numbered, white

10 pairs

numbered, white

10 pairs

Cable side from the right, jumper side from the left numbered, white

numbered, white

IDC Switching Terminal Strips C39104-A123-A40

numbered, blue

C39104-A123-A43

numbered, blue

C39104-A123-A41

C39104-A123-A42

162

numbered, blue

numbered, blue

10 pairs

10 pairs

10 pairs

10 pairs

10 pairs 10 pairs

Corning Cable Systems

IDC Terminal Strip 1000RT

19“ Rack

Ordering Information Description

Units per Delivery

C39393-A80-D53

Horizontal 19“ Rack (empty) for Series 1000RT IDC terminal strips,

1

* different sizes of mounting and full cablinet frames also available

Overvoltage / Overcurrent Terminal Strips Protection S30264-D1006-S211

Overvoltage (3-point) 230 V + 20 %, with fail safe

Overvoltage / Overcurrent (5-Point), 230 V + 20 %, with fail safe, 150 mA / PTC

* single pair protector also available

Terminal Strips Patchcords C39195-A332-A12 C39195-A332-A31

C39195-A332-A30

Patch cord 1 x 1000RT to 1 x 1000RT, 2 meters Patch cord 1 x 1000RT to 1 x RJ45, 2 meters

Patch cord 2 x 1000RT to 1 x RJ45, 2 meters

Disconnection & Blind Plugs, Tools and Labeling

1

1

1

1

C39334-A117-A3

Disconnection plug for 1 wire, color brown

1

C39104-A115-C50

Color black

10 caps

C39104-A115-C53

Color red

C39334-A117-A7

Blind plug for 1 wire, color red

Marking Accessories C39104-A115-C51

C39104-A115-C52

C39104-A115-C54 C39104-A115-C55

C39104-A115-C56 C39104-A115-C57

Termination Tools C39407-A139-A12

C39407-A149-A15

Labeling Kits C39104-A123-D1

C39104-A123-D7

Color white

FutureCom 10TEN

1

1

10 caps

Color gray

10 caps

Color blue

10 caps

Flex Wire Cable Telephone / for Patch Cord ISDN Products

S30264-D1006-S210

1

FutureCom E

4 pcs. required to install 20 terminal strips

FutureCom D

20-way mounting frames with closed jumper comb (length = 321 mm),

FutureCom UD FutureCom UE

separately

1

Hardware

2 pcs. required, mounting frames and IDC terminal strips ordered

10 caps

Color green

10 caps

Color yellow

10 caps

Color purple

10 caps

Termination Tool for connecting the wires, cutting device with lock for

optional cutting of excess wire length and extraction hook for removing wires Extraction Tool for removing modules out of extremely narrow distribution enclosures

Industrial Cable

C39104-A123-B69

Horizontal 19“ bracket to install Series 1000RT mounting frames,

1

1

Special Cable

C39393-A80-D52

IDC terminal strips ordered separately (max. 28 terminal strips; 280 pairs)

Further Information

19“ Solutions

FutureCom F

Order Number

10 pairs

100 pairs, 1 ...100

200 pairs, 1 ...200

10 pairs

Corning Cable Systems

Introduction

IDC Terminal Strips 1000RT

163

164

Corning Cable Systems

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

FutureCom 10TEN

Telephone / ISDN Products 9.1. Cat. 3 / ISDN Telephone Patch Panels

9.2. Telephone Patch Cords 168

Corning Cable Systems

165

Introduction

166 FutureCom F

9

Further Information

Table of contents

Cat. 3/ISDN Patch Panels and Telephone Patch Cords Features

19“ patch panel 1U with 50 unshielded 8-pin RJ 45 jacks

Wire connection via 4-pin LSA/110 connect dual cutting clamps for AWG 22-26

Wiring according to ISO/IEC 11801/EN 50173-1, configuration: Pin 3/6 and Pin 4/5

Grounding via M6 screw with nut and lock washer on the patch panel

Shield connection directly on the circuit board Integrated cable strain relief

Ordering Information Order Number

CAXCSV-05003-C001

Description

FutureCom™ Cat. 3/ISDN

Telephone Patch Panel, unshielded, 50xRJ45,

Units per Delivery 1/1

configuration 4.5 and 3.6, LSA-PLUS, 1U,

light-basic, RAL 7035

CAXCSV-05000-C001 FutureCom Cat. 3/ISDN Telephone Patch Panel, unshielded, 50xRJ45,

1/1

configuration 4.5 and 3.6, LSA-PLUS, 1U,

high-grade steel

166

Corning Cable Systems

Cat. 3/ISDN Patch Panels and Telephone Patch Cords

Introduction

Features

19“ patch panel 1U and 0.5U with 25 unshielded 8-pin RJ 45 jacks

Wire connection via 8-pin LSA/110 connect dual cutting

FutureCom F

clamps for AWG 22-26

Wiring according to ISO/IEC 11801/EN 50173-1, configuration: Pin 3/6 and Pin 4/5

FutureCom 10TEN

Grounding via M6 screw with nut and lock washer on the patch panel

Shield connection directly on the circuit board

CAXCSV-02503-C001

Description

FutureCom™ Cat. 3/ISDN

Telephone Patch Panel, unshielded, 25xRJ45,

FutureCom D

Order Number

Units per Delivery 1/1

FutureCom UD FutureCom UE

Ordering Information

FutureCom E

Integrated cable strain relief

configuration 4.5 and 3.6, LSA-PLUS, 1U,

FutureCom Cat. 3/ISDN Telephone Patch Panel, unshielded, 25xRJ45,

1/1

configuration 4.5 and

Industrial Cable

3.6, LSA-PLUS, 1U,

Special Cable

high-grade steel

Further Information

CAXCSV-02500-C001

Flex Wire Flex Wire CableCable Telephone / for Patch for Patch Cord Cord ISDN Products

Hardware

light-basic, RAL 7035

Corning Cable Systems

167

Cat. 3/ISDN Patch Panels and Telephone Patch Cords Ordering Information Order Number

CAXCSV-02503-C002

Description

FutureCom™ Cat. 3/ISDN

Telephone Patch Panel, unshielded, 25xRJ45,

Units per Delivery 1/1

configuration 4.5 and 3.6, LSA-PLUS, 0.5U,

light-basic, RAL 7035

CAXCSV-02500-C002 FutureCom Cat. 3/ISDN Telephone Patch Panel, unshielded, 25xRJ45,

1/1

configuration 4.5 and 3.6, LSA-PLUS, 0.5U, high-grade steel

U/UTP Flex PVC Telephone Patch Cords, ISDN/Analog Order Number

CCACOC-A6002-A005-C0 CCACOC-A6002-A010-C0

Description

ISDN Patch Cord, black, 2xRJ45 Connectors, e.g. for ISDN & analog (So, Upo, U200, U*, U2B1Q, analog a/b, a/b/c/d)

CCACOC-A6002-A015-C0

0.5 m 1m

1.5 m

CCACOC-A6002-A020-C0

2m

CCACOC-A6002-A025-C0

2.5 m

CCACOC-A6002-A030-C0

3m

CCACOC-A6002-A040-C0

4m

CCACOC-A6002-A050-C0

5m

CCACOC-A6002-A060-C0

6m

CCACOC-A6002-A100-C0

168

Length

10 m

Corning Cable Systems

Further Information

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

FutureCom 10TEN

10 Cable for Patch Cords 10.1. S/FTP Flex/26 FRNC

10.2. SF/UTP Flex/26 FRNC 172

Corning Cable Systems

169

Introduction

170 FutureCom F

Table of contents

FutureCom™ Patch Cord Cable S/FTP flex/26 FRNC

Braided shield

Halogen-free jacket, flame retardant Foil shielding (PiMF) Twisted pair

PE foam-skin insulation 4 shielded pairs

Copper flex wire, AWG 26

Mechanical Characteristics Conductor insulation Outer jacket

Area/range of application

Temperature range (installation) Operating temperature Min. bending radius

for one-time bending

Min. bending radius during installation

Copper conductor

170

Application

FutureCom™ S/FTP flex/26 patch cord cable is designed for

applications up to 600 MHz and its transmission characteristics satisfy Category 7 specifications.

FutureCom patch cord cables are a low-skew product, i.e. the

skew between the individual pairs is very low. This is increasingly required for applications above 1 Gigabit. The cable has a streamlined construction and low weight.

Each pair is individually shielded (PiMF). The stranded pairs are additionally braid shielded (S/FTP), which guarantees

outstanding shielding characteristics. The cable satisfies the standards of Class B interference radiation (EN 55022), as

well as immunitiy (EN 55024), which enables the realization of CE-compatible networks.

Halogen free

foam-skin material Halogen free

flame retardant Dry and

damp rooms 0 to +50°C

-20 to +60°C

>_ 30 mm

>_ 40 mm

Features

S/FTP flex cable, specified up to 600 MHz Outstanding electrical characteristics Cat.7 flex wire cable

Low skew between the pairs

Suitable for IDC contacts of RJ45 connectors or S1200 modules/connetors

Surface transfer impedance < 10 mV/m at 10 MHz

Flame retardant according to IEC 60332-1 , Category B Unprinted

AWG 26

Corning Cable Systems

FutureCom™ Patch Cord Cable S/FTP flex/26 FRNC Largest resistance margin

2%

Impedance Zo at 101 - 250 MHz

100 V +/- 18%

(typical value)

at 10 MHz

Introduction

Electrical Characteristics (at 20°C) >5000 MV x km

FutureCom F

100 V +/- 15%

100 V +/- 25%

FutureCom 10TEN

10 m V/m 43 pF/m 0.78 x c

FutureCom E

4.3 ns/m

4 ns/100 m

Delay skew

Frequency in MHz

1

Attenuation in dB/100m *

10

2.9

Typical values dB/100m

2.9

NEXT in dB at 100 m *

80.0

Typical values in dB at 100m

96.0

PSNEXT in dB at 100 m *

77.0

Typical values in dB at 100m

93.0

ELFEXT in dB at 100 m *

80.0

Typical values in dB at 100m

95.0

PSELFEXT in dB at 100 m *

77.0

Typical values in dB at 100m

92.0

ACR in dB

93.1

8.5

7.9

80.0

96.0 77.0

93.0 74.0

93.0 71.0

90.0 88.1

20

31.25

10.8

13.5

12.1

80.0

96.0 77.0

93.0

68.0 93.0 65.0

90.0 85.2

100

300

25.2

44.3

15.2

21.7

27.8

96.0

95.0

94.0

80.0 77.0

93.0 64.1

88.0 61.1

85.0 82.5

* Standard: Requirements for Category 7 flex cable (conforms with EN 50288-4-2)

Ordering Information

62.5

19.5 75.1

72.5

92.0 58.1

81.0 55.1

78.0 75.5

72.4

69.4 91.0

54.0 72.0 51.0

69.0 68.8

50.0

73.3

86.0

80.0

65.3

62.3

83.0 44.5

60.0 41.5

57.0 41.7

Type designation

Fire Load Zero Category Pair count (MJ/m) Halogen Color

Outer [ Weight Length (mm) (kg/km) (m) Order Number

S/FTP flex/26

7

5.8

S/FTP flex/26 S/FTP flex/26 S/FTP flex/26 S/FTP flex/26 S/FTP flex/26

7

4

0.43

Yes

gray

7

4

0.43

Yes

green

7 7 7

4 4 4 4

0.43 0.43

0.43

0.43

Yes Yes Yes Yes

blue

yellow red

black

600

63.5

60.8 57.8

77.0

38.4 51.0

35.4

48.0 16.5

5.8

42

2000 CCXFGB-G0047-0001-L8

5.8

42

2000 CCXFGB-G0047-0004-L8

5.8 5.8 5.8

Corning Cable Systems

42 42 42 42

2000 CCXFGB-G0047-0002-L8 2000 CCXFGB-G0047-0003-L8 2000 CCXFGB-G0047-0005-L8

2000 CCXFGB-G0047-0006-L8

171

FutureCom D

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

FutureCom UD FutureCom UE

Propagation velocity

Hardware

Operating capacity

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Surface transfer impedance

Industrial Cable

Impedance Zo at 251 - 600 MHz

Special Cable

Impedance Zo at 1 - 100 MHz

Further Information

Insulation resistance

FutureCom™ Patch Cord Cable SF/UTP flex/26 FRNC

Braided shield

Halogen-free jacket, flame retardant Foil shield

Twisted pair

PE foam-skin insulation 4 shielded pairs

Copper flex wire, AWG 26

Mechanical Characteristics Conductor insulation Outer jacket

Area/range of application

Temperature range (installation) Operating temperature Min. bending radius

for one-time bending

Min. bending radius during installation

Copper conductor

172

Application

The FutureCom™ SF/UTP flex/26 patch cord cable is

specified for applications up to 300 MHz and it´s outstanding transmission characteristics satisfy Channel D (2002) specifications.

FutureCom patch cord cables are low-skew products. This is increasingly required for applications above 1 Gigabit. The cable has a streamlined construction and low weight.

The stranded pairs are foil shielded and have a braided

shield (SF/UTP), which guarantees outstanding shielding

characteristics. The cable satisfies the standards for Class B interference radiation (EN 55022), as well as immunity

(EN 55024), which enables the realization of CE-compatible networks.

Halogen free

foam-skin material Halogen free

flame retardant Dry and

damp rooms 0 to +50°C

-20 to +60°C

>_ 30 mm

>_ 40 mm

Features

SF/UTP flex cable, specified up to 300 MHz Outstanding electrical characteristics Full copper braid shield Cat. 5e flex cable

Low skew between the pairs

Suitable for IDC contacts, RJ45 connectors or S1200 modules/connetors

Surface transfer impedance < 10 mV/m at 10 MHz

Flame retardant according to IEC 60332-1, Category B Unprinted

AWG 26

Corning Cable Systems

FutureCom™ Patch Cord Cable SF/UTP flex/26 FRNC Largest resistance margin

3%

Surface transfer impedance

<100 m V/m

Propagation velocity

0.74 x c

Introduction

Electrical Characteristics (at 20°C)

>150 MV x km

FutureCom F

100 V +/- 15%

at 10 MHz 4.5 ns/m

10

16

20

31.25

62.5

100

Attenuation in dB/100m *

3.2

6.0

9.5

13.6

17.1

24.8

32.0

Typical values in dB at 100m

70.0

65.0

60.0

52.0

48.0

45.0

45.0

Typical values dB/100m

3.0

NEXT in dB at 100 m *

65.3

PSNEXT in dB at 100 m *

62.3

Typical values in dB at 100m ELFEXT in dB at 100 m *

63.8 –

Typical values in dB at 100m PSELFEXT in dB at 100 m *

60.8 –

Typical values in dB at 100m ACR in dB

67.0 –

5.8

56.3 53.3 51.8 –

48.8 –

59.2 –

9.0

50.3 47.3

43.8

12.2

45.8

42.8 37.8





40.8

34.8





51.0

39.8





* Standard: Requirements for Category 5/5e flexible cable (conforms with EN-50288-2-2)

Ordering Information

14.7

42.9

39.9 33.9 –

30.9 –

33.3 –

22.5

38.4 35.4 27.9 –

24.9 –

22.5 –

27.3

35.3

32.3

23.8 –

20.8 –

17.7 –

Type designation

Fire Load Zero Category Pair count (MJ/m) Halogen Color

Outer [ Weight Length (mm) (kg/km) (m) Order Number

SF/UTP flex/26

5e

5.7

SF/UTP flex/26 SF/UTP flex/26 SF/UTP flex/26 SF/UTP flex/26

5e

4

0.43

Yes

grey

5e

4

0.43

Yes

green

5e 5e 5e

4 4 4 4

0.43

0.43 0.43 0.43

Yes Yes Yes Yes

blue

yellow red

black

48.3 35.0 – – – – – – – –

5.7

40

2000

CCXDGF-C0047-0001-L8

5.7

40

2000

CCXDGF-C0047-0004-L8

5.7 5.7 5.7

40 40 40 40

2000 2000 2000 2000

CCXDGF-C0047-0002-L8 CCXDGF-C0047-0003-L8 CCXDGF-C0047-0005-L8

CCXDGF-C0047-0006-L8

Further Information

SF/UTP flex/26

300



Hardware

1

Frequency in MHz

FutureCom D

FutureCom E

7 ns/100 m

Delay skew

FutureCom UD FutureCom UE

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

FutureCom 10TEN

48 pF/m

Operating capacity

Flex Wire Cable Telephone / for Patch Cord ISDN Products

(typical value)

Industrial Cable

Impedance Zo at 1 - 100 MHz

Special Cable

Insulation resistance

Corning Cable Systems

173

174

Corning Cable Systems

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

FutureCom 10TEN

11

Further Information

Industrial Cable

11.1. S/FTP 600/23 PUR Cable 176

11.2. SF/UTP J-09YS (ST) CH Cable

11.3. S/FTP 600 flex/26 PUR Cable 180

Corning Cable Systems

175

Introduction

178 FutureCom F

Table of contents

FutureCom™ Industrial Cable S/FTP 600/23 PUR

Application

The FutureCom™ Industrial S/FTP 600/23 cable with

polyurethane external jacket is particularly suitable for Braided shield PUR sheath

Twisted pair

Foil shielding (PiMF) PE foam-skin insulation Copper conductor AWG 23 4 shielded pairs

Mechanical Characteristics

Area/range of application

Dry and

Operating temperature Min. bending radius

for one-time bending

Min. bending radius during installation

Copper conductor

176

This cable is specified for applications to up 800 MHz and

satisfies Category 7 specifications ISO/IEC 11801 (2002) and EN 50173-1 (2003).

These cables are low-skew products, i.e. the skew between

the individual pairs is very low. This is increasingly required

for applications above 1 Gigabit. The cable has a streamlined construction and low weight.

Each pair is individually shielded (PiMF). The stranded pairs are additionally braid shielded (S/FTP), which guarantees

outstanding shielding characteristics. The cable satifies the standard for Class B interference radiation (EN 55022), as of CE-compatible networks.

Halogen free

Temperature range (installation)

with FutureCom metal outlets for industrial networks.

well as immunitiy (EN 55024), which enables the realization

Conductor insulation Outer jacket

industrial applications. It is recommended in conjunction

Foam-skin material Polyurethane damp rooms 0 to +50°C

-20 to +60°C

>_ 40 mm

>_ 60 mm AWG 23

Features

S/FTP 600/23 PUR cable, specified up to 800 MHz Outstanding electrical characteristics Each pair is shielded (PiMF) Full copper braid shield Streamlined design Lightweight

Low skew between the pairs Halogen-free (LSZH)

Flame resistant and non-corrosive

Lubricant-resistant, microbe-resistant and hydrolysisresistant

Corning Cable Systems

FutureCom™ Industrial Cable S/FTP 600/23 PUR

Unbalance to ground dB/BZL = 1000 m

FutureCom F

Surface transfer impedance

100 V +/- 18%

100 V +/- 25%

<10 m V/m at 10 MHz

FutureCom 10TEN

Impedance Zo at 251 - 600 MHz

125 V +/- 20%

>46 dB at 64 kHz

dB/BZL = 100 m

FutureCom E

>40 dB at 1 MHz

Unbalance to ground

>20 dB at 100 MHz

dB/BZL = 100 m

Propagation velocity

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz Delay skew

0.79 x c

FutureCom D

Unbalance to ground

4.2 ns/m

4 ns/100 m

1

Frequency in MHz

10

16

20

31.25

62.5

100

Attenuation in dB/100m*

2.0

Typical values in dB at 100m

>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0 77.0 77.0 77.0 77.0 77.0 72.5 69.4

Typical values dB/100m

5.7

1.7

NEXT in dB at 100 m *

5.0

80.0

PSNEXT in dB at 100 m*

Typical values in dB at 100m ELFEXT in dB at 100 m*

80.0

Typical values in dB at 100m

7.3

80.0

9.2

80.0

14.5 13.2 75.1

18.5

16.9 72.4

98.0

98.0

98.0

98.0

97.0

77.0

71.0

66.9

65.0

61.1

55.1

51.0

74.0

93.0

91.0

ACR in dB

80.0

10.1

98.0

93.0

PSELFEXT in dB at 100 m*

6.5

8.1

98.0 80.0

Typical values in dB at 100m

7.2

91.0

98.3

95.0

69.9 93.0 91.0 93.5

68.0 93.0 91.0

92.7

64.1

90.0 88.0

90.8

58.1

86.0 84.0 86.8

54.0

83.0 81.0 82.1

300

600

65.3

60.8

33.3

30.7

95.0 62.3

93.0 44.5

68.0 41.5

66.0 64.3

48.9

44.0 91.0 57.8

89.0 38.4 51.0

35.4

49.0 47.0

800

53.0 –

87.0 –

85.0 – – – –

34.0 –

* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)

Type designation

Industrial Cable

Ordering Information

Max Outer [ Weight Length Tensile Fire Load Zero Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number

Industrial S/FTP 600/23 7 4P, PUR

4

0.74

Yes

154

7.7

Corning Cable Systems

64

1000

FutureCom UD FutureCom UE

Impedance Zo at 101 - 250 MHz

>5000 MV x km

Hardware

100 V +/- 15%

Impedance Zo at 0.064 MHz

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Impedance Zo at 1 - 100 MHz

Insulation resistance

CCXIPB-F0047-C001-L7

177

Special Cable

1%

Further Information

Largest resistance margin

Introduction

Electrical Characteristics (at 20°C)

FutureCom™ Industrial 120V Cable SF/UTP J-09YS (ST) CH

Halogen-free jacket, flame retardant Star Quad

Foil shielding PP foil

Dummy element

Application

The FutureCom™ 120 V Industrial Cable is designed

specifically for data and voice transmission in industrial or

telecommuncations enviroments. These cables can be used as connecting cables or for direct installation in dry as well as damp rooms.

Braid shield

Additional wire

Foam-skin insulation Copper conductor AWG 24

Mechanical Characteristics Conductor insulation Outer jacket Jacket color

Installation area

Temperature (installation)

Polypropylene

foam-skin material

Halogen-free, flame retardent

Yellow (RAL 1021)

In dry and damp rooms -5 to +50°C

Operating temperature

-30 to +70°C

Min. bending radius during

>_ 60 mm

Min. bending radius

for one-time bending installation

Copper conductor

178

Features

Category 3 cable, specified up to 16 MHz

Category 4 cable in a quad, up to 20 MHz

Complete shielding with foil and copper braid shield Low skew between the pairs

Halogen-free, LSZH (low smoke, zero halogen)

Flame retardant according to IEC 60332-3, Category C

>_ 42 mm AWG 24

Corning Cable Systems

Frequency in MHz

0.772

1

4

10

16

20

Typical values in dB at 100 m, Quad

66

65.8

53.0

44.3

42.4

41.2

Typical values in dB/100 m

1.5

Typical values in dB at 100 m, Cable

61.5

1.75

58.9

3.3

47.2

4.9

40.3

6.8

36.9

7.6

34.7

End to end in different cables (2x60m) End to end in different cables (2x60m)

$ 75 dB

Shield attenuation (30 to 900 MHz) Operating Voltage Testing Voltage

(conductor/conductor, conductor/

shielding at 50 Hz, 1 min)

Ordering Information

Type designation

J-09YS(ST)CH 4x2x0,5 BD 120 V

FutureCom D

Max. attenuation at 1 MHz

$ 50 dB

# 19 dB/1000m $ 80 dB

FutureCom UD FutureCom UE

End to end in the same quad

300 Vss

800 Vss

Hardware

ELFEXT at 1 MHz

FutureCom E

$ 50 dB

$ 75 dB

Zero Outer[ Weight Length (kg/km) (m) Category Pair count Halogen mm Order Number 3

4

Yes

7,5

80

1000

CCXIEO-A0027-C001-L7

Flex Wire Cable Telephone / for Patch Cord ISDN Products

End to end in the same quad

120 V +/- 15V

Industrial Cable

NEXT at 1 MHz

$ 10 GV x km

Special Cable

Impedance Zo at 0.064 MHz

Further Information

Insulation resistance

FutureCom 10TEN

Electrical Characteristics (at 20°C)

FutureCom F

Electrical Characteristics (at 20°C)

Introduction

FutureCom™ Industrial 120V Cable SF/UTP J-09Ys (ST) CH

Corning Cable Systems

179

FutureCom™ Industrial S/FTP 600flex/26 PUR Cat. 7

Application Braided shield PUR jacket

Foil shielding (PiMF) Twisted pair

PE foam-skin insulation

4 shielded pairs

Copper flex wire AWG 26

Mechanical Characteristics Conductor insulation Outer jacket

Area/range of application

Temperature range (installation) Operating temperature Min. bending radius

for one-time bending

Min. bending radius during installation

Copper conductor

180

Halogen-free

foam skin material Halogen free

Flame retardent

In dry and damp rooms 0 to +50°C

-20 to +60°C

>_ 30 mm

>_ 40 mm AWG 26

The Industrial S-STP 600 flex cable with polyurethane jacket is specially designed for industrial use. It is specified up to

600 MHz and satisfies Category 7 standards, ISO/IEC 11801 (2002) and EN 50173-1 (2003).

FutureCom™ cables are low skew products, i.e. the skew be-

tween the individual pairs is very low. This is increasingly being requested for applications above Gigabit Ethernet.

Additional features are the slim design and low weight of the cables.

Each pair is individually shielded (PiMF). The stranded pairs

are additionally sheathed with a braid shield (S/FTP), which

guarantees outstanding shielding characteristics. The cable

satisfies Class B interference radiation standards (EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks.

Features

S/FTP 600 flex/26 PUR flex cable, specified up to 600 MHz

Outstanding electrical characteristics Each pair is foil-shielded (PiMF) Full copper braid shield Streamlined design Lightweight

Low skew between the pairs Halogen-free (LSZH)

Flame resistant and non-corrosive

Lubricant-, microbe- and hydrolysis resistant Unprinted

Corning Cable Systems

FutureCom™ Industrial S/FTP 600flex/26 PUR Cat. 7

Impedance Zo at 101 - 250 MHz

100 V +/- 18%

Operating capacity

43 pF/m

>5000 MV x km

Insulation resistance

FutureCom F

100 V +/- 15%

Impedance Zo at 1 - 100 MHz

100 V +/- 25%

Impedance Zo at 251 - 600 MHz

FutureCom 10TEN

<10 m V/m at 10 MHz

Surface transfer impedance

0.78 x c

Propagation velocity at >10 MHz Propagation delay >_ 10 MHz

4.3 ns/m

80.0

80.0

8.5

Typical values in dB at 100m

96.0

96.0

Typical values dB/100m

2,9

NEXT in dB at 100 m *

80.0

PSNEXT in dB at 100 m*

77.0

Typical values in dB at 100m

93.0

ELFEXT in dB at 100 m*

80.0

Typical values in dB at 100m

95.0

PSELFEXT in dB at 100 m*

77.0

Typical values in dB at 100m

92.0

ACR in dB

93.1

7.9

77.0

93.0 74.0

93.0 71.0

90.0 88.1

31.25

62.5

100

300

600

65.3

60.8

12.1

15.2

21.7

27.8

50.0

96.0

96.0

95.0

94.0

86.0

10.8 77.0

93.0

68.0 93.0 65.0

90.0 85.2

* Standard: Requirements for Category 7 flex cable (conforms with EN 50288-4-2)

13.5

80.0 77.0

93.0 64.1

88.0 61.1

85.0 82.5

19.5 75.1

72.5

92.0 58.1

81.0 55.1

78.0 75.5

25.2

72.4

69.4 91.0

54.0 72.0 51.0

69.0 68.8

44.3 62.3

83.0 44.5

60.0 41.5

57.0 41.7

73.3

FutureCom D

20

2.9

63.5

80.0

FutureCom UD FutureCom UE

10

Attenuation in dB/100m*

57.8

77.0

38.4 51.0

35.4

48.0 16.5

Hardware

1

Frequency in MHz

FutureCom E

4 ns/100 m

Delay skew

Ordering Information 7

4

0.43

Yes

5.8

42

1333

CCXIHB-G0047-0007-H2

Special Cable

Industrial S-STP 600flex/26 4P

Outer[ Weight Length Fire Load Zero (kg/km) (m) Category Pair count (MJ/m) Halogen mm Order Number

Further Information

Type designation

Flex Wire Cable Telephone / for Patch Cord ISDN Products

2%

Industrial Cable

Largest resistance margin

Introduction

Electrical Characteristics (at 20°C)

Corning Cable Systems

181

182

Corning Cable Systems

186

12.2.2. U/UTP 100/24

190

12.3.1. Fiber Blow S/FTP 900

192

12.2.2. F/UTP 300/24 12.3. Hybrid Cable

12.3.2. Fiber Blow S/FTP 600

188

194

12.3.3. S/FTP 600/23 4P + J-VH 4G50 FRNC

196

12.4.1. Cat. 6 Star Quad S/FTP 600/22 FRNC

198

12.4. ViMF Cable

12.4.2. Star Quad U/FTP 300/23 FRNC

202

Further Information

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

12.4.3. Star Quad U/FTP 300/23 PVC

200

FutureCom F

12.2.1. S/FTP 600/23 with Diffusion Barrier

FutureCom 10TEN

12.2. Outdoor Cable

FutureCom E

184

FutureCom D

12.1. F/UTP 450/23 FRNC Cable

FutureCom UD FutureCom UE

12 Special Cable

Introduction

Table of contents

Corning Cable Systems

183

FutureCom™ Cat. 6 Cable F/UTP 450/23

Application Halogen-free jacket, flame retardent Foil shielding Foil shielding Twisted pair

PE foam-skin insulation

Additional wire

Central cross member Copper conductor AWG 23

Mechanical Characteristics Conductor insulation Outer jacket

Area/range of application

Temperature range (installation) Operating temperature Min. bending radius

for one-time bending

Min. bending radius during

installation

Copper conductor

184

Halogen-free,

foam-skin material Halogen free

Flame retardent

In dry and damp rooms 0 to +50°C

-20 to +60°C

>_ 40 mm

>_ 60 mm

The FutureCom™ F/UTP 450/23 cable is designed for applications up to 450 MHz and exceeds all the requirements for Category 6 specifications.

FutureCom cables are low-skew products, i.e. the skew

between the individual pairs is very low. This is increasingly required for applications above 1 Gigabit-Ethernet. These cables have a streamlined construction and low weight.

The four stranded pairs are foil shielded (F/UTP). The cable

satisfies Class B interference radiation standards (EN 55022) as well as immunity (EN 55024) which enables the realization of CE-compatible networks.

Features

F/UTP 450/23 cable, specified up to 450 MHz Outstanding electrical characteristics Twisted pairs with 2 foil shields Low skew between the pairs Halogen-free

Flame retardant according to IEC 60332-1, Category B

Non-corrosive according to IEC 60754-2 and EN 50267 Low-smoke according to IEC 61034

AWG 23

Corning Cable Systems

20

64.0

57.3

54.2

52.8

ELFEXT in dB at 100 m per Standard *

66.0

Near-end crosstalk loss in DB per Standard *

66.0

PSNEXT in dB at 100 m per Standard *

PSELFEXT in dB at 100 m per Standard *

64.0

ACR in dB

63.9

7.6

59.3

56.2

50.0 47.0

43.0

53.3

100

250

49.9

45.4

42.3

36.3

44.0

40.1

41.0

48.6

62.5

10.7

54.8

45.9

31.25

8.5

46.3

51.9 37.1

41.2

15.5

47.4 34.1 31.1

31.9

19.9

44.3

30.0 27.0

24.4

* Standard: Requirements for 100 m installed Category 6 cable for Class E cabling links (conforms with EN 50288-5-1)

Ordering Information

Yes

Max. Tensile Strength Outer[ Weight Length (kg/km) (m) Order Number mm (N)

104

6.7

49

1000

CCXCDE-B0047-C001-L7

Hardware

0.76

5.3

Flex Wire Cable Telephone / for Patch Cord ISDN Products

4

19.0

Industrial Cable

6

22.0

Special Cable

F/UTP 450/23 4P

Fire Load Zero Category Pair count (MJ/m) Halogen

38.3

Further Information

Type designation

33.0

FutureCom F

16

6.0

FutureCom 10TEN

10

2.1

FutureCom E

1

Attenuation in dB/100m per Standard *

FutureCom D

Frequency in MHz

FutureCom UD FutureCom UE

Electrical Characteristics (at 20°C)

Introduction

FutureCom™ Cat. 6 Cable F/UTP 450/23

Corning Cable Systems

185

FutureCom™ Cat. 7 Outdoor Cable S/FTP 600/23 with Diffusion Barrier

PE sheath

Layered aluminum band Braided shield Twisted pair

Foil shielding (PiMF) PE foam-skin insulation

Copper conductor AWG 23

FRNC interior sheath 4 shielded pairs

Mechanical Characteristics

Halogen free/

Area/range of application

Outdoor installation

Temperature range (installation) Operating temperature

Min. bending radius

for one-time bending

Min. bending radius during installation

Copper conductor

The FutureCom™ S/FTP 600/23 data cable with diffusion barrier is specified up to 800 MHz. It’s transmission

characteristics satisfy Category 7 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003).

FutureCom cables are low-skew products, i.e.the skew

between the individual pairs is very low. As a result of the

aluminum composite layer sheath, this cable is suitable for direct burial. The cable has a streamlined construction and low weight.

Each pair is individually shielded (PiMF). The stranded pairs are sheathed with a braided shield (S/FTP), which guaran-

tees outstanding shielding characteristics. The cable satisfies the standard for Class B interference radiation

(EN 55022), as well as immunitiy (EN 55024), which enables the realization of CE-compatible networks.

Conductor insulation Outer jacket

Application

foam-skin material Halogen free 0 to +50°C

-20 to +60°C <_ 175 mm <_ 235 mm AWG 23

Features

S/FTP 600/23 cable, specified up to 800 MHz Outstanding electrical characteristics Each pair is shielded (PiMF) Full copper braid shield Streamlined design Lightweight

Low skew between the pairs Includes a diffusion barrier

(aluminum band and PE sheath) Halogen-free (LSZH)

Interior sheath flame retardant according to IEC 60332-3 and EN 50266-2-4

Interior sheath non-corrosive according to IEC 60754-2 and EN 50267

Interior sheath low smoke according to IEC 61034 Can be directly buried

186

Corning Cable Systems

FutureCom™ Cat. 7 Outdoor Cable S/FTP 600/23 with Diffusion Barrier Introduction

Electrical Characteristics (at 20°C) 1%

> 5000 MV x km

125 V +/- 20%

FutureCom F

100 V +/- 15%

100 V +/- 18%

100 V +/- 25%

Impedance Zo at 251 - 600 MHz

FutureCom 10TEN

<10 m V/m at 10 MHz

Surface transfer impedance

>46 dB at 64 kHz

Unbalance to ground dB/BZL = 1000 m dB/BZL = 100 m

FutureCom E

>40 dB at 1 MHz

Unbalance to ground

>20 dB at 100 MHz

Unbalance to ground dB/BZL = 100 m

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

FutureCom D

0.79 x c

Propagation velocity

4.2 ns/m

4 ns/100 m

Delay skew

1

Frequency in MHz

Attenuation in dB/100m *

2.0

Typical values dB/100m

1.7

NEXT in dB at 100 m *

80.0

10

5.7

5.0

16

7.2

6.5

20

31.25

8.1

10.1

7.3

9.2

62.5 14.5 13.2

100

18.5

16.9

80.0 80.0 80.0 80.0 75.1 72.4 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 99.0 77.0 77.0 77.0 77.0 77.0 72.5 69.4

Typical values in dB at 100m PSNEXT in dB at 100 m *

Typical values in dB at 100m ELFEXT in dB at 100 m *

98.0

98.0

98.0

98.0

98.0

98.0

97.0

77.0

71.0

66.9

65.0

61.1

55.1

51.0

80.0

Typical values in dB at 100m

93.0

PSELFEXT in dB at 100 m *

Typical values in dB at 100m

91.0

ACR in dB

98.3

74.0

93.0 91.0

95.0

69.9 93.0 91.0 93.5

68.0

64.1

93.0

90.0

91.0

88.0

92.7

90.8

58.1

86.0 84.0 86.8

54.0

83.0 81.0 82.1

300

600

65.3

60.8

33.3

30.7

95.0 62.3

93.0 44.5

68.0 41.5

66.0 64.3

48.9

44.0 91.0 57.8

89.0 38.4 51.0

35.4

49.0 47.0

800

53.0 –

87.0 –

85.0 – – – –

34.0 –

* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)

S/FTP 600/23 4P

Industrial Cable

Ordering Information Type designation

Max Outer [ Weight Length Tensile Fire Load Zero Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number 7

4

2.98

Yes

400

11.7

Corning Cable Systems

126

1000

FutureCom UD FutureCom UE

Impedance Zo at 101 - 250 MHz

Hardware

Impedance Zo at 1 - 100 MHz

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Impedance Zo at 0.064 MHz

CCXSDB-F0047-C001-L7

187

Special Cable

Insulation resistance

Further Information

Largest resistance margin

FutureCom™ Cat. 5e Outdoor Cable F/UTP 300/24 PE

Foil shielding

PE-outer sheath

2 wires stranded to a pair Foil shielding

Additional wire

PE foam-skin PE insulation

Copper conductor AWG 24

Color Coding

4 shielded pairs

Pair 1

White with blue rings/blue

Pair 4

White with brown rings/brown

Pair 2 Pair 3

White with orange rings/orange

Wire insulation

Halogen free

Area/range of application

Outdoor installation

Sheath material

Temperature range (in motion)

PE foam-skin material PE

0 to +50°C

Operating temperature

-60 to +60°C

Min. bending radius

>50 mm

Min. bending radius

for one-time bending

Diameter of the copper conductor

188

The FutureCom™ F/UTP 300/24 PE cable is designed for out-

door applications up to 300 MHz and provides transmission performance exceeding Category 5e ISO/IEC 11801 (2002) and EN 50173-1 (2003) specifications.

The improved operating temperature of up to -60°C is

appropriate for the use under most adverse conditions.

This cables are low skew products, i.e. the difference in propagation delay between the individual pairs is

very low. This is increasingly being requested for Gigabit

Ethernet. The cable as a streamlined construction and low weight.

The stranded pairs are surrounded by foils (F/UTP). The cable satisfies Class B interference radiation

(EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks.

White with green rings/green

Mechanical Characteristics

during installation

Application

>35 mm

AWG 24

Features

F/UTP 300/24 PE cable, specified up to 300 MHz Outdoor cable specified up to -60°C Excellent electrical characteristics

Full shielding including 2 foils with additional tinned copper wire Slim design

Lightweight

Low skew between the pairs PE jacket

Corning Cable Systems

FutureCom™ Cat. 5e Outdoor Cable F/UTP 300/24 PE Introduction

Electrical Characteristics (at 20°C) 2%

>5000 MV x km 185 V/km

Surface transfer impedance

<10 m V/m at 10 MHz

Unbalance to ground

>40 dB at 1 MHz

FutureCom F

100 V +/- 15%

dB/BZL = 1000 m dB/BZL = 100 m

FutureCom 10TEN

>46 dB at 64 kHz

Unbalance to ground

dB/BZL = 100 m

FutureCom E

>20 dB at 100 MHz

Unbalance to ground

0.74 * c

Propogation velocity at >10 MHz (NVP * c)

4.5 ns/m

Signal delay >10 MHz

FutureCom D

7 ns/100 m

Delay margin

Frequency in MHz

1

NEXT in dB at 100 m to standard*

65.3

Attenuation in dB/100m according to standard* Typical values dB/100m

Typical values in dB at 100m

PSNEXT in dB at 100 m according to standard* Typical values in dB at 100m

ELFEXT in dB at 100 m according to standard* Typical values in dB at 100m

PSELFEXT in dB at 100 m according to standard* Typical values in dB at 100m ACR in dB

10

16

20

31.25

62.5

100

38.4

35.3

2.1

6.3

8.0

9.0

11.4

16.5

77.0

62.0

59.0

57.0

54.0

50.0

2.0

5.6

50.3

62.3

47.3

75.0

60.0

63.8

43.8

72.0

60.0

60.8

40.8

70.0

58.0

74.9

55.9

7.2

47.3

44.2 57.0 39.7

54.0 36.7

52.0 51.4

8.0

45.8

42.8 55.0 37.8

52.0

34.8

50.0 48.5

10.1

42.9

39.9 52.0

33.9

48.0 30.9

46.0 43.5

21.3

14.4

35.4

48.0 27.9

40.0 24.9 38.0 34.9

18.2

46.0 32.3

44.0 23.8

34.0 20.8 32.0 26.7

250

29.5 –

38.5 –

36.5 –

22.1 –

20.1 –

7.0

300

32.2 –

35.0 –

33.0 –

17.0 –

15.0 –

0.9

* Standard: Requirements for 100 m installed Category 5e cable for Class D cabling sections (corresponds to EN 50288-2-1)

Ordering Information F/UTP 300/24 PE

5e

4

No

-60°C

82

6,2

36

1000

Industrial Cable

Std. Max Outer [ Weight Length Min. Tem- Tensile Zero Category Pair count Halogen perature Strength (N) (mm) (kg/km) (m) Order Number

CCXDAE-C0047-C001-L7

Further Information

Type designation

FutureCom UD FutureCom UE

Impedance Zo at 1 - 100 MHz

Hardware

DC resistance

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Insulation resistance

Special Cable

Largest resistance margin

Corning Cable Systems

189

FutureCom™ Cat. 5e Outdoor Cable U/UTP 100/24 PE

PE-outer jacket

2 wires stranded to a pair PE foam-skin PE insulation

4 unshielded pairs Copper conductor AWG 24

Color Coding Pair 1

White with blue rings/blue

Pair 4

White with brown rings/brown

Pair 2 Pair 3

White with orange rings/orange White with green rings/green

Mechanical Characteristics Wire insulation

Halogen free

Area/range of application

Outdoor installation

PE foam-skin material

Application

The FutureCom™ U/UTP 100/24 PE cables are designed for

outdoor applications up to 100 MHz and provides transmission performance exceeding Category 5e ISO/IEC 11801

(2002) and EN 50173-1 (2003) specifications. The improved

operating temperature of up to -60°C/-40°C is appropriate

for the employment under most, even adverse, conditions.

This cables are low skew products, i.e. the difference in propagation delay between the individual pairs is very low. This is increasingly being requested for e.g. Gigabit Ethernet.

The cable has a streamlined construction and low weight.

The cable satisfies Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of CE-compatible networks.

Features

U/UTP 100/24 cable , specified up to 100 MHz Outdoor cable specified up to -40°C/-60°C

PE

Excellent electrical characteristics

Operating temperature

-60 to +60°C

Lightweight

Min. bending radius

>50 mm

Sheath material

Temperature range (in motion) Min. bending radius

for one-time bending during installation

Diameter of the copper conductor

190

0 to +50°C

>35 mm

Core and pairs are unshielded Slim design

Low skew between the pairs PE jacket

AWG 24

Corning Cable Systems

FutureCom™ Cat. 5e Outdoor Cable U/UTP 100/24 PE

FutureCom F

45 pF/m

4.5 ns/m

Signal delay >10 MHz

7 ns/100 m

Delay margin

Frequency in MHz

1

10

16

20

31.25

62.5

100

NEXT in dB at 100 m to standard*

65.3

50,3

47,3

45,8

42,9

38.4

35.3

Attenuation in dB/100m according to standard*

2.1

Typical values dB/100m

1.9

Typical values in dB at 100m

77.4

PSNEXT in dB at 100 m according to standard*

62.3

Typical values in dB at 100m

74.0

ELFEXT in dB at 100 m according to standard*

63.8

Typical values in dB at 100m

68.0

PSELFEXT in dB at 100 m according to standard*

60.8

Typical values in dB at 100m

66.0

ACR in dB

74.1

6.3 5.9

65.5 47.3

60.0 43.8

49.0 40.8 47.0 56.1

8.0 7.4

62.2

44.2

56.0 39.7

45.0 36.7

43.0

50.6

9.0 8.4

59.7

42.8

54.0 37.8

42.0 34.8

40.0 47.6

11.4

10.5 57.7

39.9 51.0

33.9

40.0 30.9

38.0 42.5

16.5 15.1

49.6 35.4

47.0 27.9

33.0

24.9 31.0

33.9

21.3

19.3

46.6 32.3

44.0 23.8

28.0 20.8

26.0 26.7

*Standard: Requirements for 100 m installed Category 5e cable for Class D cabling sections (corresponds to EN 50288-3-1)

Ordering Information Type designation

Std. Max Outer [ Weight Length Min. Tem- Tensile Zero Category Pair count Halogen perature Strength (N) (mm) (kg/km) (m) Order Number

U/UTP 100/24 PE

5e

4 4

No No

-40°C

-60°C

82 82

5.4 5.4

28 28

1000 1000

CCXUAE-C0047-C001-L7

CCXUAE-C0047-C002-L7

Special Cable

5e

Further Information

U/UTP 100/24 PE

FutureCom E

at >10 MHz (NVP * c)

FutureCom 10TEN

0.74 x c

Propogation velocity

FutureCom D

Mutual capacity

FutureCom UD FutureCom UE

100 V +/- 15%

185 V/km

DC resistance

Hardware

Impedance Zo at 1 - 100 MHz

>5000 MV x km

Insulation resistance

Flex Wire Cable Telephone / for Patch Cord ISDN Products

3%

Industrial Cable

Largest resistance margin

Introduction

Electrical Characteristics (at 20°C)

Corning Cable Systems

191

FutureCom™ Hybrid-Cable Fiber Blow S/FTP 900/23

Braided shield

Halogen-free jacket, flame retardant Twisted pair

Foil shielding (PiMF) 4 shielded pairs

PE foam-skin insulation Copper conductor AWG 23 Tube for insertion of fibers

Application

The FutureCom™ S/FTP 900/23 fiber blow is prepared for the subsequent insertion of up to 12 fibers (single or multimode fibers with 250 µm diameter can be inserted). Future-proof cabling, for example fiber-to-the-desk (FTTD), can be easily

realized. The integrated copper data cable is specified for applications up to 1000 MHz and its transmission characteristics satisfy Category 7 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003).

FutureCom cables are low-skew products, i.e. the skew

between the individual pairs is very low. This is increasingly required for applications above 1 Gigabit. The cable has a streamlined construction and low weight. Each pair is

individually shielded (PiMF). The stranded pairs are sheathed with a braided shield (S/FTP), which guarantees outstanding shielding characteristics. The cable satisfies the standards

for Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of

Mechanical Characteristics Conductor insulation Outer jacket

Area/range of application

Temperature range (installation) Operating temperature

CE-compatible networks.

Halogen free

foam-skin material Halogen free

flame retardant Dry and

damp rooms 0 to +50°C

-20 to +60°C

Min. bending radius

>_ 100 mm

installation

(over flat side*)

for one-time bending

Min. bending radius during Copper conductor

(over flat side*) >_ 100 mm

Features

Fiber blow S/FTP 900/23, specified up to 1000 MHz Outstanding electrical characteristics

Each pair is individually shielded with foil Full copper braid shield

Low skew between the pairs

Prepared for the subsequent insertion of up to 12 fibers Halogen-free (LSZH)

Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034

AWG 23

* Max. cabling length of 90 m with 12 x 90° bends for a radius of 100 mm

192

Corning Cable Systems

FutureCom™ Hybrid-Cable Fiber Blow S/FTP 900/23

100 V +/- 15%

FutureCom F

125 V +/- 20%

100 V +/- 18%

Impedance Zo at 101 - 250 MHz

100 V +/- 25%

Impedance Zo at 251 - 600 MHz

FutureCom 10TEN

<10 m V/m at 10 MHz

Surface transfer impedance

>46 dB at 64 kHz

Unbalance to ground dB/BZL = 1000 m dB/BZL = 100 m

FutureCom E

>40 dB at 1 MHz

Unbalance to ground

>20 dB at 100 MHz

Unbalance to ground dB/BZL = 100 m

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

FutureCom D

0.79 x c

Propagation velocity

4.2 ns/m

4 ns/100 m

Delay skew

Frequency in MHz

1

NEXT in dB 100 m *

80.0

Attenuation in dB/100m*

2.0

Typical values dB/100m

1.7

Typical values in dB at 100m

10

5.7

5.0

80.0

16

7.2

6.5

80.0

20

8.1

7.3

80.0

31.25

10.1 9.2

80.0

62.5

100

75.1

72.4

14.5 13.2

18.5

16.8

300

600

65.3

60.8

33.3

30.0

>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3

PSNEXT in dB at 100 m*

Typical values in dB at 100m ELFEXT in dB at 100 m*

98.0

98.0

98.0

98.0

98.0

98.0

98.0

94.0

77.0

71.0

66.9

65.0

61.1

55.1

51.0

41.5

80.0

Typical values in dB at 100m

93.0

PSELFEXT in dB at 100 m*

Typical values in dB at 100m

91.0

ACR in dB

98.3

74.0

93.0 91.0

95.0

69.9 93.0 91.0 93.5

68.0 93.0 91.0

92.7

64.1

90.0 88.0

90.8

58.1

86.0 84.0 86.8

54.0

83.0 81.0

83.2

44.5

68.0

66.0 66.0

48.9 42.5

92.0 57.8

90.0 38.4 51.0

35.4

49.0 49.5

900

55.0 –

86.0 –

84.0 – –

1000 59.0 –

83.0 –

81.0 – –













31.0

24.0

Industrial Cable

* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)

Ordering Information S/FTP 900/23 4P Fiber Blow

7

4

0.6

Yes

154

7.5x16

Corning Cable Systems

118

500

Special Cable

Type designation

Max Outer [ Weight Length Tensile Fire Load Zero Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number

WCXWDW-I0047-C001-L6

193

Further Information

Impedance Zo at 0.064 MHz

FutureCom UD FutureCom UE

Impedance Zo at 1 - 100 MHz

>5000 MV x km

Insulation resistance

Hardware

1%

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Largest resistance margin

Introduction

Electrical Characteristics (at 20°C)

FutureCom™ Hybrid-Cable Fiber Blow S/FTP 600/23

Braided shield

Halogen-free jacket, flame retardant Twisted pair

Foil shielding (PiMF) 4 shielded pairs

PE foam-skin insulation Copper conductor AWG 23 Tube for insertion of fibers

Application

The FutureCom™ S/FTP 600/23 fiber blow is prepared for the subsequent insertion of up to 12 fibers (single or multimode fibers with 250 µm diameter can be inserted). Future-proof cabling, for example fiber-to-the-desk (FTTD), can be easily

realized. The integrated copper data cable is specified for applications up to 800 MHz and its transmission characteristics satisfy Category 7 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003).

FutureCom cables are low-skew products, i.e. the skew

between the individual pairs is very low. This is increasingly required for applications above 1 Gigabit. The cable has a

streamlined construction and low weight. Each pair is individually shielded (PiMF). The stranded pairs are sheathed

with a braided shield (S/FTP), which guarantees outstanding shielding characteristics. The cable satisfies the standards for Class B interference radiation (EN 55022), as well as immunity (EN 55024), which enables the realization of

Mechanical Characteristics Conductor insulation Outer jacket

Area/range of application

Temperature range (installation) Operating temperature

CE-compatible networks.

Halogen free

foam-skin material Halogen free

flame retardant Dry and

damp rooms 0 to +50°C

-20 to +60°C

Min. bending radius

>_ 100 mm

installation

(over flat side*)

for one-time bending

Min. bending radius during

Copper conductor

(over flat side*) >_ 100 mm

Features

Fiber blow S/FTP 600/23 cable, specified up to 800 MHz Outstanding electrical characteristics

Each pair is individually shielded with foil Full copper braid shield

Low skew between the pairs

Prepared for the subsequent insertion of up to 12 fibers Halogen-free (LSZH)

Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034

AWG 23

* Max. cabling length of 90 m with 12 x 90° bends with regard to a radius of 100 mm

194

Corning Cable Systems

FutureCom™ Hybrid-Cable Fiber Blow S/FTP 600

100 V +/- 15%

FutureCom F

125 V +/- 20%

100 V +/- 18%

Impedance Zo at 101 - 250 MHz

100 V +/- 25%

Impedance Zo at 251 - 600 MHz

FutureCom 10TEN

<10 m V/m at 10 MHz

Surface transfer impedance

>46 dB at 64 kHz

Unbalance to ground dB/BZL = 1000 m dB/BZL = 100 m

FutureCom E

>40 dB at 1 MHz

Unbalance to ground

>20 dB at 100 MHz

Unbalance to ground dB/BZL = 100 m

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

FutureCom D

0.79 x c

Propagation velocity

4.2 ns/m

4 ns/100 m

Delay skew

Frequency in MHz

1

10

16

20

80.0

80.0

80.0

80.0

31.25

62.5

100

80.0

75.1

72.4

300

600

Attenuation in dB/100m *

2.0

33.3

48.9

Typical values in dB at 100m Typical values in dB at 100m

>100.0 >100.0 >100.0 >100.0 >100.0 >100.0 >100.0 96.0 77.0 77.0 77.0 77.0 77.0 72.5 69.4 62.3 98.0 98.0 98.0 98.0 98.0 98.0 98.0 94.0

92.0

PSELFEXT in dB at 100 m *

77.0

Typical values dB/100m

1.7

NEXT in dB 100 m *

PSNEXT in dB at 100 m * ELFEXT in dB at 100 m *

Typical values in dB at 100m ACR in dB

7.2

5.0

6.5

8.1

7.3

10.1 9.2

14.5 13.2

18.5

16.8

30.0 65.3

80.0

74.0

69.9

68.0

64.1

58.1

54.0

44.5

91.0

91.0

91.0

91.0

88.0

84.0

81.0

66.0

93.0

Typical values in dB at 100m

5.7

98.3

93.0

93.0

71.0

66.9

95.0

93.5

93.0 65.0 92.7

90.0 61.1

90.8

86.0 55.1

86.8

83.0 51.0

83.2

68.0 41.5

66.0

42.5

60.8 57.8

90.0 38.4 51.0

35.4

49.0 49.5

800

53.0 –

87.0 –

85.0 – – – –

34.0 –

* Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)

S/FTP 600/23 4P Fiber Blow

Max Outer [Weight Length Tensile Fire Load Zero Category Pair count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number 7

4

0.6

Yes

154

7.5x16 118

Corning Cable Systems

500

Special Cable

Type designation

Industrial Cable

Ordering Information

WCXWDW-F0047-C001-L6

195

Further Information

Impedance Zo at 0.064 MHz

FutureCom UD FutureCom UE

Impedance Zo at 1 - 100 MHz

>5000 MV x km

Insulation resistance

Hardware

1%

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Largest resistance margin

Introduction

Electrical Characteristics (at 20°C)

FutureCom™ Hybrid Cable S/FTP 600/23 4P + J-VH 4G50 FRNC

Braided shield

Halogen-free jacket, flame retardant Twisted pair

Foil shielding (PiMF) 4 shielded pairs

PE foam-skin insulation

Copper conductor AWG 23

Halogen-free jacket, flame retardant Rip-cord

900 µm tight buffered fiber Fiber

Strain relief (aramide yarn)

Application

LANscape® Hybrid cables enable the simultaneous installa-

tion of a fiber optic and copper data cable.

Corning fiber optic multifiber interior cables (MIC) are par-

ticularly suitable for installation into cable conduits or ducts (both vertically and horizontally), false floors, as jumpers or

adapter cables and for connecting workstations inside buildings (FTTD - Fiber-to-the-Desk). They can also be used as inter-building connecting cables in dry conduits. The 900µm tight-buffer design allows easy and direct field connectorization.

The FutureCom™ S/FTP 600/23 copper cable is specified for

applications up to 800 MHz and its transmission characteristics satisfy Category 7 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003). A high level of system

performance for the complete channel is achieved by using this high-quality Category 7 cable.

The low skew between the pairs emphasizes their suitability for applications above 1 Gigabit Ethernet. Due to its out-

standing shielding characteristics, the cable satisfies the

standards for Class B interference radiation (EN 55022), as

well as immunity (EN 55024), which enables the realization of CE-compatible networks.

Features

Fiber Optic Cable

FO cable with 900µm tight-buffered fibers,

TB-3 construction enables easy, consistent stripping

Particularly suitable for field-installable UniCam® connectors

Telecordia color-coding

Completely dry construction

Copper Cable

S/FTP 600/23 cable, specified up to 800 MHz Outstanding electrical characteristics

Each pair is individually shielded with foil Full copper braid shield

Low skew between the pairs Halogen-free (LSZH)

Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034

196

Corning Cable Systems

foam-skin material

Outer jacket

Halogen free

flame retardant

Area/range of application

0 to +50°C

Operating temperature

-20 to +60°C

Min. bending radius

>_ 40 mm (for 2x

installation

(4x2...) over flat side)

(4x2...) over flat side)

for one-time bending

>_ 60 mm (for 2x

Min. bending radius during Copper conductor

AWG 23

Frequency in MHz

Largest resistance margin

1%

Impedance Zo at 1 - 100 MHz

100 V +/- 15%

Impedance Zo at 0.064 MHz

1

10

16

100 V +/- 18%

Unbalance to ground

>46 dB at 64 kHz

80.0

80.0

80.0

dB/BZL = 1000 m dB/BZL = 100 m dB/BZL = 100 m

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

Typical values in dB at 100m

>100.0 >100.0 >100.0 >100.0

5.7

NEXT in dB 100 m *

PSNEXT in dB at 100 m *

5.0

77.0

Typical values in dB at 100m

77.0

98.0

ELFEXT in dB at 100 m *

98.0

80.0

Typical values in dB at 100m

74.0

93.0

PSELFEXT in dB at 100 m * *

93.0

77.0

Typical values in dB at 100m

71.0

91.0

ACR in dB

91.0

98.3

95.0

7.2

6.5

77.0

98.0 69.9 93.0

66.9 91.0 93.5

FutureCom F

0.79 x c

Propagation velocity

20

8.1

7.3

80.0 77.0

98.0 68.0 93.0 65.0 91.0

92.7

31.25

62.5

80.0

75.1

10.1 9.2

>100.0 77.0

98.0 64.1

90.0 61.1

88.0

90.8

14.5 13.2

<10 m V/m at 10 MHz

>20 dB at 100 MHz

Unbalance to ground

Delay skew

100 V +/- 25%

>40 dB at 1 MHz

Unbalance to ground

2.0 1.7

125 V +/- 20%

Impedance Zo at 101 - 250 MHz

Attenuation in dB/100m* Typical values dB/100m

>5000 MV x km

Insulation resistance

Surface transfer impedance

damp rooms

Temperature range (installation)

Electrical Characteristics (at 20°C)

Impedance Zo at 251 - 600 MHz

Dry and

100 m

4.2 ns/m 100

4 ns/100 m

18.5

16.8

72.4 >100.0 >100.0 72.5 69.4 98.0

98.0

55.1

51.0

58.1

86.0 84.0 86.8

FutureCom 10TEN

Halogen free

0.8

10 Gbit/s

FutureCom E

Conductor insulation

600 m

1 Gbit/s

FutureCom D

Mechanical Characteristics

0.7

1300 nm

FutureCom UD FutureCom UE

2.5

2.7

850 nm

1300 nm

54.0

83.0 81.0

83.2

300

600

65.3

60.8

33.3

30.0

96.0 62.3

94.0 44.5

68.0 41.5

66.0 66.0

48.9 42.5

92.0 57.8

90.0 38.4 51.0

35.4

49.0 49.5

800

53.0 –

87.0 –

85.0 – – – –

34.0

WCXWXW-X0087-C001-L6



*Standard: Requirements for 100 m installed Category 7 cable for Class E/F cabling sections (conforms with EN 50288-4-1)

Type designation J-VH 4G50L/125 +

S/FTP 600/23 FRNC

Pair/fiber Category count 7

4/4

Max Outer [ Weight Length Tensile Fire Load Zero Order Number (MJ/m) Halogen Strength (N)(mm) (kg/km) (m) 1.44

Yes

154

7.5x15.5 110

Corning Cable Systems

500

Special Cable

Ordering Information

Hardware

InfiniCor® OM2 (50 µm)

850 nm

Guaranteed minimum distance at

Industrial Cable

Features

Typ. attenuation in the tight buffer cable in dB/km

Further Information

Fiber Type

Typ. attenuation Loose Tube Cables

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Fiber Specification - Laser-Optimized InfiniCor® Multimode Fibers

Introduction

FutureCom™ Hybrid Cable S/FTP 600/23 4P + J-VH 4G50 FRNC

197

FutureCom™ ViMF Cat.6 Cable (Star Quad) S/FTP 600/22 FRNC

Application

The FutureCom™ StarQuad ViMF Cable is designed for

applications in industrial and other harsh environments up Braided shield

Halogen-free jacket, flame retardant Foil shielding

1 twisted quad

PE foam-skin insulation Copper conductor AWG 22 PP foil

Mechanical Characteristics Conductor insulation Outer jacket

Area/range of application

Temperature range (installation) Operating temperature

Halogen free

foam-skin material Halogen free

flame retardant Dry and

damp rooms

skew between the individual pairs of foursomes is very low.

This is increasingly required for applications above 1 Gigabit Ethernet. The cable has a streamlined construction and low weight.

StarQuad ViMF Cables are intended for multimedia applications (voice, image and data communications) where cable sharing is an option. Alongside traditional applications

(ISDN, Ethernet and Token Ring), the cables are suitable for

systems with high frequency areas, such as TPDDI via copper

S/FTP 600/22 cable, specified up to 600 MHz Outstanding electrical characteristics

Each StarQuad (foursome) is shielded (ViMF)

Different color coding of individual foursomes

Simultaneous, standard-conforming transmission of multiple services is possible

Very robust, thus particularly suitable for application in

-5 to +50°C

industrial and other harsh environments

(over flat side*)

Halogen-free (LSZH)

-20 to +60°C

(over flat side*)

198

FutureCom ViMF Cables are zero-skew products, i.e. the

Features

installation

Copper conductor

EN 50173-1 (2003).

1000 Base-T.

>_ 26 mm

Min. bending radius during

6 specifications according to ISO/IEC 11801 (2002) and

(TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to

Min. bending radius

for one-time bending

to 600 MHz. Its transmission characteristics satisfy Category

>_ 40 mm AWG 22

Full copper braid shield

Zero skew between the foursomes

Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034

Corning Cable Systems

FutureCom™ ViMF Cat.6 Cable (Star Quad) S/FTP 600/22 FRNC

100 V +/- 15%

FutureCom F

125 V +/- 20%

<10 m V/m at 10 MHz

Surface transfer impedance dB/BZL = 1000 m

FutureCom 10TEN

>46 dB at 64 kHz

Unbalance to ground

>40 dB at 1 MHz

Unbalance to ground dB/BZL = 100 m

Greatest possible loop resistance 130 V/km

FutureCom E

48 pF/m

Operating capacity

0.74 x c

Propagation velocity

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

4.9 ns/m

FutureCom D

0 ns/100 m

Delay skew

1

Frequency in MHz

10

16

20

31.25

62.5

100

250

Attenuation in dB/100 m *

2.1

6.0

7.6

8.5

10.8

15.5

19.9

33.0

Typical values in dB at 100 m (pair/pair)

78.6

67.5

64.0

62.0

59.0

54.5

51.8

45.0

Typical values dB/100m

1.5

NEXT in dB at 100 m *

66.0

Typical values in dB at 100 m (foursome/foursome)

90.0

PSNEXT in dB at 100 m *

64.0

Typical values in dB at 100m

75.6

ELFEXT in dB at 100 m *

66.0

Typical values in dB at 100m

75.0

PSELFEXT in dB at 100m *

64.0

Typical values in dB at 100m

73.0

ACR in dB

77.1

4.9

59.3

90.0 57.3

64.5 50.0

65.0 47.0

63.0

62.6

6.3

56.2

90.0 54.2

61.0

45.9

62.0 43.0

60.0 57.7

7.1

54.8

90.0 52.8

59.0

44.0

60.0 41.0

58.0 54.9

9.0

51.9

90.0 49.9 56.0 40.1

54.0 37.1

52.0

50.0

12.9

47.4

90.0 45.4 51.5

34.1

44.0 31.1

42.0 41.6

16.5

44.3

90.0 42.3

48.8 30.0

36.0 27.0

34.0 35.3

26.9 38.3 75.0

36.3

42.0 22.0 17.0

19.0 15.0 18.1

600

43.6 –

38.0 –

70.0 35.0 – – – – –

* Standard: Requirements for 100 m installed Category 6 cable for Class E cabling sections (conforms with EN 50288-5-1)

Industrial Cable



Ordering Information S/FTP 600/22 ViMF 6

2

0.89

Yes

179

5.2x8.3 75

Corning Cable Systems

1000

Special Cable

Type designation

Max Outer [ Weight Length Tensile Fire Load Zero Category Quad count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number

CCXSCD-F0027-C001-L7

199

Further Information

Impedance Zo at 0.064 MHz

FutureCom UD FutureCom UE

Impedance Zo at 1 - 100 MHz

>5000 MV x km

Insulation resistance

Hardware

1%

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Largest resistance margin

Introduction

Electrical Characteristics (at 20°C)

FutureCom™ ViMF Cat. 5 Cable (Star Quad) U/FTP 300/23 FRNC

Foil shielding Halogen-free jacket

Foil shielding 1 twisted quad

Additional wire

PE insulation Copper conductor AWG 23 PP foil

Application

The FutureCom™ StarQuad ViMF Cable is designed for

applications in industrial and other harsh environments up to 300 MHz and its transmission characteristics satisfy

Category 5 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003).

FutureCom ViMF Cables are zero-skew products. i.e. the

skew between the individual pairs of foursomes is very low. This is increasingly required for Gigabit-Ethernet.

StarQuad ViMF Cables are intended for multimedia applications (voice, image and data communications) where cable sharing is an option. Alongside traditional applications

(ISDN, Ethernet and Token Ring), the cables are suitable for high frequency transmission, such as TPDDI via copper (TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to 1000 Base-T.

Features

U/FTP 300/23 cable, specified up to 300 MHz Outstanding electrical characteristics

Each StarQuad (foursome) is shielded (ViMF)

Simultaneous, standard-conforming transmission of multiple services is possible

Very robust, thus particularly suitable for application in industrial and other harsh environments

Full shielding including one PP foil and 2 aluminum-clad foils

Zero skew between the foursomes Halogen-free (LSZH)

Flame retardant according to IEC 60332-3, Category C Non-corrosive according to IEC 60754-2 (FRNC) Low smoke according to IEC 61034

Available in 2, 3, 4 and 7 foursomes

200

Corning Cable Systems

FutureCom™ ViMF Cat. 5 Cable (Star Quad) U/FTP 300/23 FRNC

Temperature range (installation) Operating temperature Min. bending radius

for one-time bending

damp rooms 0 to +50°C

-20 to +60°C

2V: >_ 30 mm (flat side) 3V: >_ 50 mm 4V: >_ 52 mm 7V: >_ 65 mm

Min. bending radius during

2V: >_ 45 mm (flat side) 3V: >_ 75 mm

installation

4V: >_ 78 mm

7V: >_ 100 mm

Copper conductor

AWG 23

1

Frequency in MHz

dB/BZL = 1000 m

Unbalance to ground dB/BZL = 100 m

Greatest possible loop resistance Operating capacity

Propagation velocity

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

16

20

31.25

>40 dB at 1 MHz 130 V/km 48 pF/m 0.68 x c

4.9 ns/m

0 ns/100 m

Delay skew

10

62.5

100

Attenuation in dB/100 m *

2.1

6.3

8.0

9.0

11.4

16.5

21.3

Typical values in dB at 100 m (pair/pair)

80.0

64.0

61.0

60.0

56.0

50.5

47.0

Typical values dB/100m

1.8

NEXT in dB at 100 m *

65.3

Typical values in dB at 100 m (foursome/foursome)

90.0

PSNEXT in dB at 100 m *

62.3

Typical values in dB at 100m

76.7

ELFEXT in dB at 100 m according *

63.8

Typical values in dB at 100m

75.0

PSELFEXT in dB at 100m according *

60.8

Typical values in dB at 100m

73.0

ACR in dB

78.2

5.2

50.3

90.0 47.3 61.1

43.8

64.0 40.8

62.0 58.8

6.7

47.2

90.0 44.2 57.8

39.7

61.0 36.7

59.0 54.3

7.5

45.8

90.0 42.8

56.9 37.8

59.0 34.8 57.0 52.5

9.4

42.9

90.0 39.9 52.8

33.9 53.0

30.9 51.0

46.6

Introduction

<10 m V/m at 10 MHz

>46 dB at 64 kHz

Unbalance to ground

13.7

38.4

90.0 35.4 47.5 27.9

47.0

24.9 45.0

36.8

17.6

35.3

90.0 32.3

44.0 23.8

43.0 20.8 41.0

29.4

200

300

41.0

38.3

25.1 – –

80.0 38.0 –

32.0 –

30.0 –

15.9

30.9 –

80.0 35.3 –

22.0 –

20.0 –

7.4

*Standard: Requirements for 100 m installed Category 5 cable for Class D cabling sections (conforms with EN 50288-2-1)

Type designation U/FTP 300/23 3V

5

U/FTP 300/23 2V

U/FTP 300/23 4V U/FTP 300/23 7V

5

2

0.89

Yes

110

5.6x9.6 79

5

7

3.28

Yes

390

13.2

5

3

4

1.71

1.95

Yes Yes

165

220

10.1

10.4

Corning Cable Systems

105 125

219

Industrial Cable

Ordering Information

Max Outer [ Weight Length Tensile Fire Load Zero Category Quad count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number 1000

CCXSDC-C0022-C001-L7

1000

CCXSDC-C0072-C001-L7

500 500

FutureCom F

Dry and

100 V +/- 15%

Surface transfer impedance

FutureCom 10TEN

Area/range of application

Impedance Zo at 1 - 100 MHz

FutureCom E

flame retardant

125 V +/- 20%

Impedance Zo at 0.064 MHz

FutureCom D

Halogen free

>5000 MV x km

Insulation resistance

FutureCom UD FutureCom UE

Outer jacket

2%

Hardware

foam-skin material

Largest resistance margin

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Halogen free

CCXSDC-C0032-C001-L6

CCXSDC-C0042-C001-L6

201

Special Cable

Conductor insulation

Electrical Characteristics (at 20°C)

Further Information

Mechanical Characteristics

FutureCom™ ViMF Cat. 5 Cable (Star Quad) U/FTP 300/23 PVC

Foil shielding Schirmfolie PVC jacket Mantel PVC

Foil shielding Schirmfolie

Additional wire Beidraht

twisted quad 41 Adern zum Vierer verseilt PE insulation PE-Isolierung Copper conductor AWG 23 Kupferleiter AWG 23 PP foil

Application

The FutureCom™ StarQuad ViMF cable is designed for

applications in industrial and other harsh environments up to 300 MHz and its transmission characteristics satisfy

Category 5 specifications according to ISO/IEC 11801 (2002) and EN 50173-1 (2003).

FutureCom ViMF cables are zero-skew products, i.e. the skew

between the individual pairs of foursomes is very low. This is increasingly required for Gigabit-Ethernet.

StarQuad ViMF cables are intended for multimedia applications (voice, image and data communications) where cable sharing is an option. Alongside traditional applications

(ISDN, Ethernet and Token Ring), the cables are suitable for high frequency transmissions, such as TPDDI via copper (TP-PMD), 100Base-TX, 100 Base-VG and ATM, up to 1000 Base-T.

Features

U/FTP 300/23 cable, specified up to 300 MHz Outstanding electrical characteristics

Each StarQuad (foursome) is shielded (ViMF)

Simultaneous, standard-conforming transmission of multiple services is possible

Very robust, thus particularly suitable for application in industrial and other harsh environments suitable

Full shielding including one PP foil and 2 aluminum-clad foils

Zero skew between the foursomes PVC jacket

Flame retardant according to IEC 60332-1, Category B Available in 1, 2, 3, and 4 foursomes

202

Corning Cable Systems

Temperature range (installation) Operating temperature Min. bending radius

for one-time bending

damp rooms

-20 to +60°C

1V: >_ 30 mm

3V: >_ 50 mm 4V: >_ 52 mm 1V: >_ 45 mm

installation

2V: >_ 45 mm (flat side) 3V: >_ 75 mm

4V: >_ 78 mm

Copper conductor

>46 dB at 64 kHz

<10 m V/m at 10 MHz

dB/BZL = 1000 m

0 to +50°C

2V: >_ 30 mm (flat side)

Min. bending radius during

Unbalance to ground

AWG 23

1

Frequency in MHz

Unbalance to ground dB/BZL = 100 m

Greatest possible loop resistance Operating capacity

Propagation velocity

at >10 MHz (NVP x c) Propagation delay >_ 10 MHz

16

20

31.25

130 V/km 48 pF/m 0.68 x c

4.9 ns/m

0 ns/100 m

Delay skew

10

>40 dB at 1 MHz

62.5

100

Attenuation in dB/100 m *

2.1

6.3

8.0

9.0

11.4

16.5

21.3

Typical values in dB at 100 m (pair/pair)

80.0

64.0

61.0

60.0

56.0

50.5

47.0

Typical values dB/100m

1.8

NEXT in dB at 100 m *

65.3

Typical values in dB at 100 m (foursome/foursome)

90.0

PSNEXT in dB at 100 m *

62.3

Typical values in dB at 100m

76.7

ELFEXT in dB at 100 m *

63.8

Typical values in dB at 100m

75.0

PSELFEXT in dB at 100m *

60.8

Typical values in dB at 100m

73.0

ACR in dB

78.2

5.2

50.3

90.0 47.3 61.1

43.8

64.0 40.8

62.0 58.8

6.7

47.2

90.0 44.2 57.8

39.7

61.0 36.7

59.0 54.3

7.5

45.8

90.0 42.8

56.9 37.8

59.0 34.8 57.0 52.5

9.4

42.9

90.0 39.9 52.8

33.9 53.0

30.9 51.0

46.6

13.7

38.4

90.0 35.4 47.5 27.9

47.0

24.9 45.0

36.8

17.6

35.3

90.0 32.3

44.0 23.8

43.0 20.8 41.0

29.4

200

25.1 –

41.0 –

80.0 38.0 –

32.0 –

30.0 –

15.9

300

30.9 –

38.3 –

80.0 35.3 –

22.0 –

20.0 –

7.4

*Standard: Requirements for 100 m installed Category 5 cable for Class D cabling sections (conforms with EN 50288-2-1)

Type designation U/FTP 300/23 2V

5

U/FTP 300/23 1V

U/FTP 300/23 3V

U/FTP 300/23 4V

Industrial Cable

Ordering Information

Std. Max Outer [ Weight Length Tensile Fire Load Zero Category Quad count (MJ/m) Halogen Strength (N) (mm) (kg/km) (m) Order Number 5

1

0.65

No

55

5.5

39

1000

CCXSKC-C0012-C001-L7

5

4

2.00

No

220

10.4

125

500

CCXSKC-C0042-C001-L6

5

2 3

1.23 1.71

No No

110

165

5.5x9.4 76 10.1

Corning Cable Systems

105

1000 500

FutureCom F

Dry and

Surface transfer impedance

FutureCom 10TEN

Area/range of application

100 V +/- 15%

Impedance Zo at 1 - 100 MHz

FutureCom E

flame retardant

125 V +/- 20%

FutureCom D

Halogen free

Impedance Zo at 0.064 MHz

FutureCom UD FutureCom UE

Outer jacket

> 5000 MV x km

Insulation resistance

Hardware

foam-skin material

2%

Largest resistance margin

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Halogen free

CCXSKC-C0022-C001-L7

CCXSKC-C0032-C001-L6

203

Special Cable

Conductor insulation

Electrical Characteristics (at 20°C)

Further Information

Mechanical Characteristics

Introduction

FutureCom™ ViMF Cat. 5 Cable (Star Quad) U/FTP 300/23 PVC

204

Corning Cable Systems

Further Information

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

13 Further Information 13.1. Training

206

13.2. EWP

13.3. Glossary

209

13.4. Type Codes

13.5. Product Index 211

212

Corning Cable Systems

205

FutureCom F

Introduction

207

FutureCom 10TEN

Table of contents

LANscape® Training Training: Expertise for Your Employees

Total communication solutions are becoming increasingly

important for communication networks, in particular local

area networks (LANs) because the future lies in the convergence of voice, video and data. Around the globe, as infor-

mation infrastructures evolve, so the demands on the quality of networked communication solutions continue to

grow. Meeting these demands calls for knowledge - knowledge that we can pass on to you.

Techniques and products are subject to constant change. This makes it essential to have highly trained employees

who know how to exploit technical progress to your advantage. This can only be achieved with continuous training.

As a leading provider of communication cables, hardware and services, we are working with our customers to build

communication highways for the future. We realize that the planning, installation and maintenance of cable systems

calls for comprehensive technical knowledge - something

we want to share with you in spirit of genuine partnership.

For more Information about LANscape® Training: On the Internet:

http://www.corning.com/cablesystems

We Train – You Benefit

Our worldwide knowledge in cable and network technology

is channeled to our Training Center. It is from this knowledge base that we develop a wide range of seminars for your employees. Our training is aimed at all organizations involved in constructing or operating cable systems in the private networks or carrier area. By undertaking training before

starting on a project, you can avoid costly installation errors, and take a decisive step towards ensuring a successful outcome to your project.

Practical Orientation – Not Just Theory

The balance between the two is critical: theory is necessary,

but practice dictates what is done. From many years of practical experience, our trainers know which knowledge and skills are required for each task, and they are in constant

contact with development, sales and project engineering teams at Corning Cable Systems.

Our Training Centers are located in Berlin and Neustadt /

Coburg, Germany. Standard and customized courses to meet

Or via E-Mail:

individual requirements are held locally throughout the world, where the technical facilities permit.

[email protected] Or by phone under:

Freephone: 00800 2676 4641 Detailed training information is available on request.

Course Portfolio Private Networks:

LANscape® Certified Approved Installer Courses for

Structured Premises Cabling

LANscape® Copper Approved Installer

LANscape® Copper Approved Installer – Refresher LANscape® Fiber Optic Approved Installer

LANscape® Fiber Optic Approved Installer - Refresher

206

Corning Cable Systems

LANscape® Cabling Solutions: A Name You Can Trust Introduction

Meeting and Exceeding Global Standards

We guarantee that each customized Corning Cable Systems LANscape® Cabling Solution meets or exceeds the global

FutureCom F

data communication and performance standards. You can

and trained.

Each partner-company meets our stringent requirements for technical experience, financial strength and proven dedication to quality. EWP partners must demonstrate ongoing

products withstand rigorous field and laboratory testing

with continual design enhancements in response to rapidly evolving customer environments.

Ready for Your Growing Network

Corning Cable Systems understands the critical need for flexible solutions with the rapid growth of your data

communications requirements. With Corning Cable Systems’ LANscape® Solutions, changes and expansions are cost-

effective and simple. Your cost-of-ownership is minimized!

Expert Service and Support

Corning Cable Systems’ experts support and assist Extended Warranty Program installers with the planning, designing,

and installing of fiber optic and high-end copper cabling systems.. With world-wide distribution channels and a high

class Customer Service Center, Corning Cable Systems makes it easy for EWP installers to quickly get products to your site for installation. Highly trained sales consultants located in your area are available for on-site evaluations and cabling recommendations.

Special Cable

update training at least once every two years.

systems to the customer. Corning Cable Systems LANscape®

Further Information

commitment to extensive training and are required to

The LANscape® end to end product offering is designed to

FutureCom E

deliver the most technologically advanced communications

Corning Cable Systems’ network of LANscape® Extended

FutureCom D

Warranty Program™ (EWP) installers are carefully selected

FutureCom UD FutureCom UE

LANscape® Solutions Total Package

Hardware

Installation Expertise and Reliability

Flex Wire Cable Telephone / for Patch Cord ISDN Products

ISO/IEC 11801 and EN 50173 (Europe).

Industrial Cable

ures up to the international cabling requirements,

FutureCom 10TEN

be assured that your Corning Cable Systems Solution meas-

Corning Cable Systems

207

LANscape® Solutions: A Name You Can Trust Extended Warranty – Extra Value

Corning Cable Systems’ LANscape® Extended Warranty

protects your LANscape Fiber Optic and/or High-end Copper Solution for a full 25 years*. The warranty covers total sys-

tem performance as well as each product component of the Corning Cable Systems’ solution. Corning Cable Systems

Total Corporate Assurance

EWP 25-year system warranty is offered when all products in

rily on fiber cabling solutions while also offering high-end

guarantees to repair or replace defective products for 25

years after installation by an EWP Partner. The LANscape®

the cabling solution (cables, connectivity, and interconnect-

ing hardware) are Corning Cable Systems products installed by an EWP Partner.

Corning Cable Systems is the only company focusing primacopper solutions. Our mission is to remain the world’s

leading developer and manufacturer of fiber optic and

high-end copper products for voice, data, and video applications. Corning Cable Systems’ resources for research and product development, financial strength, and mature

business focus are clearly unmatched in the communications industry.

Corning is the inventor of the first commercial optical fibers and the world leader in optical fiber manufacturing for over 25 years. Our unique heritage makes Corning Cable Systems the one company that can offer a solid corporate foundation, a tradition of quality, and a name you can trust.

How You Benefit

LANscape® 25 years warranty

Installation by Corning Cable Systems Approved partners

Partners trained on the latest technology Corning Cable Systems total quality

*The Extended Warranty of Corning Cable Systems is subject to the terms and conditions set forth in the EWP Contract to be signed by each EWP Partner and set forth in the Warranty Statement granted to the endcustomer of an installation. The liability of Corning Cable Systems for failures /malfunction or alterations of the specifications published at the date of installation is repair or replacement of the defective product. Corning Cable Systems shall not be liable for any consequential damages or violation of the contract terms with respect to the warranty obligation for this product. The maximum liability of Corning Cable Systems within the scope of the Extended Warranty Program is repair and replacement of the Corning Cable Systems product that does not comply with the Corning Cable Systems specifications published at the date of installation of such product plus labor costs in connection with the replacement or the repair of such products amounting to a maximum of Euro 10.000 (ten thousand).

208

Corning Cable Systems

Cable sheath

Capacitance unbalance

Characteristic impedance Conductor

Conductor resistance Corrosive

DC loop resistance Delay skew Dielectric ELFEXT FEXT

Fire rating

Flame retardant Frequency FRNC

Impedance Insulation resistance

packets of fixed size. ATM supports data transfer rates of from 25 to 622 Mbps (megabits per second).

American designation for conductor diameter (American Wire Gauge)

The totality of cabling elements in the cable and the wrapping covering all these elements.

Covering, generally of polyethylene (PE), polyvinylchloride (PVC) or zero-halogen material (H), to protect the cable core against environmental influences.

The difference between the ground capacitances of the two conductors.

Complex quantity defining the ratio of voltages to currents in a propagating wave at every point along the line.

The conductor is used for transporting the electrical charge carriers and is therefore made of electrically conducting material (metal). The conductor is usually round.

Conductor resistance is determined by the quality of the copper used and the cross-section of the conductor. It increases linearly with cable length and has a determining influence on the attenuation.

Release of corrosive gases and acids by the combustion of cables and lines. For indoor installations, non-corrosive cables should be used. Halogen-free cables are generally non corrosive. Overall DC resistance of the go and return conductors (unit: ?/km)

The difference in time between the arrival (reception) of a data signal and subsequent related data signals. Usually expressed in nanoseconds.

Insulating material, also termed dielectric medium, i.e. an electrically non-conducting material A measurement of the unwanted signal coupling from a transmitter at the near end into another pair, measured at the far end with the effects of the attenuation removed.

Far-end crosstalk loss is the attenuation between the transmission circuits of a cable at the different ends of the cable.

Sum of the combustion heat of all the combustible materials located in a room (unit for cables: MJ/m)

Description of the behavior of products with respect to fire propagation. Enhanced flame retardancy is generally required only for indoor cables. Number of complete cycles per second (in Hz). Flame retardant (FR) and non corrosive (NC)

Impedance of an electrical four-terminal network. It comprises the DC resistance and the

reactance, the latter being the frequency-dependent opposition to current flow offered by

inductances and capacitances. Impedance is physically determined by the dimensions of inner conductor, dielectric and shield.

This is determined by the insulating material and more particularly by the nature of the

insulant than by its thickness. The insulation resistance is length dependent.

Corning Cable Systems

FutureCom F FutureCom 10TEN

Asynchronous Transfer Mode is a network technology based on transferring data in cells or

FutureCom E

Cable core

cable in the stationary condition (unit: dB/km or dB/100m).

FutureCom D

AWG

Known also as attenuation coefficient, it is the length related attenuation introduced by the

FutureCom UD FutureCom UE

ATM

frequency dependent and caused mainly by resistance and the skin effect (unit: dB)

Further Information

Attenuation constant

Hardware

Reduction in electrical signal power between two defined points on a transmission path. It is

cable.

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Attenuation

Crosstalk noise from other cables in a bundle of cables or from a second cable unit in a duplex

Industrial Cable

Attenuation-to-crosstalk ratio

ANEXT

Special Cable

ACR

Introduction

Glossary

209

Glossary LAN: Local Area Network

Length of lay LS0H/LSZH

Mutual capacitance NEXT

Propagation delay

Propagation velocity PS-ACR

PSANEXT

PSELFEXT PSNEXT Quad

Resistance unbalance Return loss Shield

Shielding Skew

Skin effect

Smoke density

Transfer impedance Twisted pair Wire

210

Local network for bit-serial transmission between interconnected, independent terminal

equipments. The term LAN was introduced in order to distinguish this network from processor links (central processor unit with peripherals) operating at very high bit rates over short distances on the one hand and from publicly accessible networks operating over long distances on the other.

The distance along the center axis of a cable that a cabling element advances in order to complete one full turn (360°) about this axis. Low smoke (LS) and zero halogen (0H) Effective capacitance of the line

Near-end crosstalk loss is the attenuation between the transmission circuits of a cable at the same end of the cable.

The time required for a signal to pass along a transmission line. The velocity of wave propagation along a transmission line.

The difference between attenuation and PSNEXT. The result is referred to as “head room”. The more head room a cable or system has the more forgiving it will be with the installation errors (apart from mis-wiring).

Sum of the unwanted signal coupling of crosstalk noise at the near end from external cabling pairs into an affected pair of cable.

A computed sum value of the individual ELFEXT effects on each pair by the other 3 pairs. ELFEXT removes the impact of insertion loss on Far End Crosstalk.

The sum of all pair combinations for crosstalk as it occurs when a signal is introduced into a communications cable, and measured at the near end to the transmitter

A series of four separately insulated conductors, generally twisted together. Difference in DC resistance between two wires of a circuit (unit: ?)

The difference between the power incident upon a discontinuity in a transmission system and the power reflected from the discontinuity.

Structural cable element for shielding. The design of the shield depends on whether one is

seeking protection against electric fields (capacitive coupling) or magnetic fields (inductive

coupling) or against both. Shielding materials against magnetic fields should always have a high electrical conductivity and small inductance, which is why, in the case of conductors, copper is mostly used.

Protects against electric and magnetic influence caused by emission (emitted interference) and emission (received interference).

A measure of the inequality of propagation delay between two pairs in a multi-pair cable Tendency for higher frequency currents to travel near the outside surface of a conductor

Measure of the smoke generated by a burning cable. For indoor installation, cables should be selected with a low smoke density (typical value: 50%).

Surface transfer impedance is a measure of the effectiveness of the shielding and is defined as the ratio of the voltage along the shield of the disturbed system to the current in the disturbing system.

A transmission line in which two insulated conductors are twisted together.

The wire is a conductor with a surrounding insulant. The insulant can be air or other electrically non-conducting material (usually plastic).

Corning Cable Systems

Further Information

Special Cable

Industrial Cable

Flex Wire Cable Telephone / for Patch Cord ISDN Products

Hardware

FutureCom UD FutureCom UE

FutureCom D

FutureCom E

FutureCom 10TEN

FutureCom F

Introduction

Type Codes for Copper Cables

Corning Cable Systems

211