Evolution METRO Release Notes Release R10C00

NG-SW\00341 Rev.A

Evolution Metro Release Notes

Release R10C00

Revision History Rev

Date

Author

Description

Approved by

Date

A

12.12.2012

Mikal Lund

Initial version

Espen Børresen

14.12.2012

Page 2 of 41

Evolution Metro Release Notes

Release R10C00

Table of Contents 1. Introduction ...................................................................................................... 4 1.1

Purpose and scope ........................................................................................................ 5

2. Current Software versions ............................................................................... 5 2.1

SW components ............................................................................................................. 5

3. Compatibility..................................................................................................... 8 3.1

HW version vs. SW version compatibility....................................................................... 8

3.2

HW version vs. SW features ........................................................................................ 10

3.3

XCVR HW and SW support ......................................................................................... 12

3.4

SW Package Releases ................................................................................................ 13

3.5

New Functionality in R10C00 ....................................................................................... 33

4. Bugfixes IN R10C00 ........................................................................................ 34 4.1

XPIC Polarization tooltip is configurable ...................................................................... 34

4.2

Routing of STM-4 and DXC ......................................................................................... 34

4.3

Pattern Loss and errors on STM-4 board .................................................................... 34

5. INSTALLATION OF R10C00 PACKAGE ......................................................... 35 5.1

Procedure ..................................................................................................................... 35

6. KNOWN PROBLEMS ...................................................................................... 39 6.1

OSPF Router ................................................................................................................ 39

6.2

XPAND Upgrade from R4A00 ...................................................................................... 39

6.3

Memory Limitations Supervisory Unit FKCN5551A-T and FKCN5551B-T .................. 39

6.4

Ethernet Configuration Mismatch Gigabit Interface Unit FNZ5695A-T ........................ 39

6.5

Software downgrade to R6B02 or earlier revisions – Gigabit Interface Unit ............... 40

6.6

Software downgrade to revisions earlier than R7A00 .................................................. 40

6.7

Access rights on DXC unit and DXC Frame ................................................................ 40

6.8

Upgrading to N+1 systems from earlier releases than R8A00 .................................... 40

6.9

Memory Limitations DXC Frame .................................................................................. 40

6.10 DXC Frame SETS status and alarm reporting. ............................................................ 40 6.11 Upgrade of Supervisory Unit from FKCN5551A/B/C-T to FKCN5551D-T. .................. 41 6.12 Housekeeping wizard – Indoor Radio Placement page ............................................... 41

Page 3 of 41

Evolution Metro Release Notes

Release R10C00

Figure 1: Downloading tar file ............................................................................... 36 Figure 2: Activating the SU after SW switch ........................................................ 37 Figure 3: Status after software switch .................................................................. 38

Page 4 of 41

Evolution Metro Release Notes

Release R10C00

1. Introduction 1.1 Purpose and scope This document describes functionality and updates in Release R10B00 of the Universal IFU system for Evolution Series family of radio relay systems.

2. Current Software versions 2.1 SW components The table below lists all the existing software versions for each software component in the Universal IFU system, Evolution Series family of radio relay systems. The SW components that are released together with this CSI are marked with X. Table 2.1-1: Current boot software versions

Component

Unit

SW-FUNF5560ABOOT

RADIO

SW-FKCN5551ABOOT

SW-SBC-BOOT

SW-SBCII-BOOT

Version R1A00

Release date

Changed now

2006-January

R1A00

2006-February

R2A00

2006-February

R3A00

2006-September

R4A00

2007-November

R5A00

2009-May

IFU Basic Frame

R2A02

2007-November

All Plug-in Units

R2A03

2008 – October

IFU Basic Frame

R1A00

2008- July

DXC Frame

R1B00

2010-March

SU BOARD

Page 5 of 41

Evolution Metro Release Notes

Release R10C00

Table 2.1-2: Current application software versions Component

Unit

Version

Release date

SW-EVOLUTION-RELEASE1

SU BOARD

R1A00

2006 – February

R1A01

2006 – March

R1B00

2006 – May

R2A00

2006 – June

R2B00

2006-September

R2B01

2006-October

SW-EVOLUTION-RELEASE2

SU BOARD

Changed now

SW-EVOLUTION-RELEASE3

SU BOARD

R3A00

2006 – October

SW-EVOLUTION-RELEASE3B

SU BOARD

R3B00

2006 – December

SW-EVOLUTION-RELEASE4A

SU BOARD

R4A00

2007- March

R4A01

2007- March

R4A02

2007-May

R4B00

2007-June

R4B01

2007-June

R4B02

2007 - June

R5A00

2007-July

R5A01

2007-September

R5B00

2007-September

R5B01

2007-November

R6A00

2007-November

R6A01

2007- December

R6B00

2008-January

R6B01

2008-February

R6B02

2008-April

R6C00

2008-May

R6C01

2008-October

R7A00

2008-July

R7A01

2008-August

R7A02

2008-October

R7A03

2008-December

R7A04

2009 - March

R8A00

2009 – January

R8A01

2009 – March

R8A02

2009 – April

R8A03

2009 - August

SW-EVOLUTION-RELEASE4B

SW-EVOLUTION-RELEASE5A

SW-EVOLUTION-RELEASE5B

SW-EVOLUTION-RELEASE6A

SW-EVOLUTION-RELEASE6B

SW-EVOLUTION-RELEASE6C

SW-EVOLUTION-RELEASE7A

SW-EVOLUTION-RELEASE8A

SU BOARD

SU BOARD

SU BOARD

SU BOARD

SU BOARD

SU BOARD

SU BOARD

SU BOARD

Page 6 of 41

Evolution Metro Release Notes

Release R10C00

Component

Unit

Version

Release date

SW-EVOLUTION-RELEASE9A

SU BOARD

R9A00

2009 – May

R9A01

2009 – July

R9A02

2009 – October

R9A03

2009-November

R9B00

2009 – Sept

R9B01

2009 – November

R9B02

2010 - January

R9B03

2010 – March

R10A00

2010 – April

R10A01

2010 – October

R10A02

2011 – May

R10A03

2011 – Nov

SW-EVOLUTION-RELEASE9B

SW-EVOLUTIONRELEASE10A

SU BOARD

SU BOARD

Changed now

SW-EVOLUTIONRELEASE10B

SU BOARD

R10B00

2012 – February

SW-EVOLUTIONRELEASE10C

SU BOARD

R10C00

2012 – December

Page 7 of 41

X

Evolution Metro Release Notes

Release R10C00

3. Compatibility 3.1 HW version vs. SW version compatibility The Evolution Series SW consists of a SW package containing all field downloadable SW components. The components in a package are compatible. BOOT SW can not be downloaded in field. Table 3.2: SU HW unit/board revision and the first SW to support it. HW unit

HW code

HW revision

SW-EVOLUTION-RELEASE revision

SU BOARD

FKCN5551A-T

R1A or higher

SW-FKCN5551A-BOOT revision

R1A, R1B, R2A and R2B

R2A00

R3A00 or any SW packages released after

R3A00 or later

Table 3.3: SU HW unit/board revision and the first SW to support it. HW unit

HW code

HW revision

SW-EVOLUTION-RELEASE3 revision

SW-FKCN5551A-BOOT revision

SU BOARD

FKCN5551B-T

R1A or higher

R3A00 or any SW packages released after

R3A00 or later

Table 3.4: SU HW unit/board revision and the first SW to support it. HW unit

HW code

HW revision

SW-EVOLUTION-RELEASE6 revision

SW-FKCN5551A-BOOT revision

SU BOARD

FKCN5551C-T

R1A or higher

R6A00 or any SW packages released after

R4A00 or later

Table 3.5: SU HW unit/board revision and the first SW to support it. HW unit

HW code

HW revision

SW-EVOLUTION-RELEASE9 revision

SW-FKCN5551A-BOOT revision

SU BOARD

FKCN5551D-T

R1A or higher

R9A00 or any SW packages released after

R5A00 or later

Page 8 of 41

Evolution Metro Release Notes

Release R10C00

SW-EVOLUTION-RELEASE10A R10B00 contains SW support for the following HW: Table 3.6: SW Evolution Series Package board support HW unit

HW code

HW revision

SU BOARD

FKCN5551A-T

R1A00 or higher

FKCN5551B-T FKCN5551C-T FKCN5551D-T XVCR MAIN BOARD

FUNF5560A-T

R1A00 or higher

FUNF5560B-T XVCR MAIN BOARD ACM

FUNF5898A-T

R1A00 or higher

FUNF5898B-T

XVCR BIAS BOARDs

FERU5173B

R1A00 or higher

FERU5185B RIU 155 BOARD

FDM5559A-T

R1A00 or higher

RIU 311 BOARD

FDM5559B-T

R1A00 or higher

RIU BOARD

FDM5559C-T

R1A00 or higher

RIU BOARD

FDM5559D-T

R1A00 or higher

RIU BOARD

FDM5559E-T

R1A00 or higher

RIU BOARD

FDM5559F-T

R1A00 or higher

LIU STM-1/STS-3

FLDM5554A-T

R1A00 or higher

LIU S-1.1/OC-3 IR-1

FLDY5623A-T

LIU L-1.1/OC-3 LR-1

FLDY5689A-T

LIU L-1.2/OC-3 LR-2

FLDY5690A-T

LIU OC-3 SR-0

FLDY5691A-T

IFU FRAME

FUBU6325A-T

R1A00 or higher

FUBU6325B-T

R1A00 or higher

FUBU6325C-T

R1A00 or higher

AUXILIARY BOARDS (EOW)

FNF5660A-T

R1A00 or higher

AUXILIARY BOARDS

FKN5661A-T

R1A00 or higher

FKN5674A-T

R1A00 or higher

FN5688A-T

R1A00 or higher

(64kb/s) AUXILIARY BOARDS (Alm&Ctrl) AUXILIARY BOARDS (E1/T1 Wayside) Page 9 of 41

Evolution Metro Release Notes

Release R10C00

HW unit

HW code

HW revision

LIU 25*E1 BOARDS

FNCS5684A-T

R1A00 or higher

LIU 12*E1 BOARDS

FNCS5685A-T

R1A00 or higher

DXC

FNCS5670A-T

R1A00 or higher

LIU 16*T1 BOARDS

FNCS5686A-T

R1A00 or higher

LIU 8*T1 BOARDS

FNCS5687A-T

R1A00 or higher

GIGABIT

FNZ5695A-T

R1A00 or higher

FNZ5695B-T

R1A00 or higher

LIU 3xDS3/E3

FNCS5669A-T

R1A00 or higher

LIU STM-4/OC-12

FLDY5692A-T

R1A00 or higher

2 SHELF ASSEMBLY

UBM6407/UBM6407B

R1A00 or higher

4 SHELF ASSEMBLY

UBM6408/UBM6408B

R1A00 or higher

SHELF ASSY 4 IFU DXC

UBM6409

R1A00 or higher

IFU DXC FRAME

FUBU6663A-T

R1A00 or higher

POWER AND SYNC

FWPN5735A-T

R1A00 or higher

3.2 HW version vs. SW features Please note the following details regarding HW unit version and functionality: SU BOARD FKCN5551A-T

Does not support frequency diversity systems with more than 1 regular channel Does not support systems with more than 2 IFUs Does not support more than 2 Gigabit units in the system Does not support SU Ethernet in XPAND Does not support SU Ethernet in Wayside channel (METRO) Does not support configurations with DXC Frame (METRO) SU BOARD FKCN5551B-T

Does not support systems with more than 2 IFUs (max 4 ODUs/XCVRs) Page 10 of 41

Evolution Metro Release Notes

Release R10C00

Does not support more than 2 Gigabit units in the system Does not support configurations with DXC Frame (METRO) Supports SU Ethernet mapping in XPAND Supports SU Ethernet in Wayside channel (METRO) Supports Ethernet packet size up to 1536 byte (SU Ethernet) SU BOARD FKCN5551C-T

Supports up to 8 ODUs /XCVRs Supports more than 2 Gigabit units in the system Supports SU Ethernet mapping in XPAND Supports SU Ethernet in Wayside channel (METRO) Supports Ethernet packet size up to 2048 byte (SU Ethernet) SU BOARD FKCN5551D-T

Supports up to 8 ODUs /XCVRs Supports more than 2 Gigabit units in the system Supports SU Ethernet mapping in XPAND Supports SU Ethernet in Wayside channel (METRO) Supports Ethernet packet size up to 1632 byte (SU Ethernet) Supports QoS and VLAN switching IFU BASIC FRAME (UNIVERSAL IFU) FUBU6325A-T

Supports up to 3 +1 frequency diversity systems in shelf assembly 2IFU. Does not support frequency diversity systems with more than 3 regular channels IFU BASIC FRAME (UNIVERSAL IFU) FUBU6325B-T

Supports up to 7 +1 frequency diversity systems IFU BASIC FRAME (UNIVERSAL IFU) FUBU6325C-T Supported in SW-EVOLUTION-RELEASE10A and later revisions for all configurations.

GIGABIT INTERFACE UNIT FNZ5695A-T

Capacity limitation of 250 Mb/s on QoS setting for link capacity above 155 Mb/s

Page 11 of 41

Evolution Metro Release Notes

Release R10C00

GIGABIT INTERFACE UNIT FNZ5695B-T

Supports QoS for link capacity above 155 Mb/s

3.3 XCVR HW and SW support The XCVR HW has been modified and requires updated SW. The table below details which SW version is the first to support these specific HW variants. XCVR Type

XCVR code

XCVR Rev

SW

HP XCVR

FL**AAB0B

R2* R3*

R10A03 R10B00

HP SD XCVR

FL**ABB0B

R2* R3*

R10A03 R10B00

SP XCVR

FL**AAA0B

R2*

R10B00

HP XCVR

FL**AAB0C

R2*

R10B00

HP SD XCVR

FL**ABB0C

R2*

R10B00

HP XCVR

FL05AAB0C

R2*

R10C00

HP SD XCVR

FL05ABB0C

R2*

R10C00

HP XCVR

FL11AAB0C

R2*

R10C00

HP SD XCVR

FL11ABB0C

R2*

R10C00

Type B XCVR

Type C XCVR

R10B00 supports Type C XCVRs for frequencies: Lower 6, Upper 6, 7 & 8 GHz

Page 12 of 41

Evolution Metro Release Notes

Release R10C00

3.4 SW Package Releases This release includes the following Release 1 functionality: Main Functionality System

Includes Terminal  1+0  2+0  HSB  HSB Dual Baseband  1+1 (no LPT)  1+0 in 2 Ant. directions

Description STM-1/OC-3[155Mb/s] Access solution Split mount (outdoor)

Hybrid Space Diversity Modulation

Frequencies

XPIC L6 GHz 7 GHz 13 GHz 15 GHz

Frame/Plug-In Units

Line Interface Electrical STM1/STS-3 Unit

128 TCM

ACAP, CCDP ACAP, CCDP ACAP, CCDP ACAP, CCDP Configuration, Test and alarms

Line Interface Optical Unit Opt SM OC-3 IR-1/STM-1 S1.1 Radio Interface Unit IFU Basic Frame Transceiver Unit Ethernet Interface on SU Management

Fan Unit Ethernet 1x10/100Mbit/s BaseT Web Server Command Line Interface Internet Protocol (Ipv4) SNMP Communication Ports

IP Router

Alarm and performance surveillance  LAN (TP)  2 Radio DCC  Line DCC  1 USB ports for serial communication OSPF and RIP routing possibilities. Configuration of parameters

Page 13 of 41

Evolution Metro Release Notes

Configuration

Release R10C00

System Housekeeping SNTP SW Licensing Real Time Clock Configuration Upload/Download/Restore

Inventory

Production Data per board SW version per board

Software Download

Download of the following SW components to the different boards via SU.

  

System Application SW Transceiver Application SW FPGA codes

SW Versions Fault

Alarms Alarm Event Notification

Internal and for SNMP

Configuration of Alarm Event Notification Alarm Severity Configuration Alarm Blocking Configuration Network Element Fault Log Analogue

Analogue Measurements

RF Input Level (dBm) Tx Output Level (dBm)

Performance

Temperature Measurements

For FAN control

G.826 calculations on B1, B2 and MS REI

All applicable units

- Cumulative, 15min, Day and Month Cumulative error pulses and block pulses - B1, B2 and MS REI OOF Pulses G.826 performance alarm thresholds

Page 14 of 41

Evolution Metro Release Notes

Security

Release R10C00

Access Control via username and password Security Log

Test

RPS

Looping and PRBS Configuration of 1+1 and HSB

All applicable units

Switch/Restore Limits Bi-directional/ Unidirectional Manual Control Reverting/Non-reverting

Alarms

Page 15 of 41

Evolution Metro Release Notes

Release R10C00

In addition the following Release 2 functionality of the Evolution Series SW is supported: Main Functionality System

Includes Line Terminal Modulation

Description SU Ethernet to Line/Optical 64 TCM 32 TCM

SBC Frequencies

Field downloadable U6 GHz 18 GHz 8 GHz 23 GHz 11 GHz

Frame/Plug-In Units

EOW Auxiliary Unit

Configure service channel and station phone number Configuration and control of 64kb/s channels for interconnection to other terminals Configuration of analogue interface for connecting other service channel equipment Alarms Inventory: Production data and SW version Test: Looping and PRBS

Line Interface Optical Unit Opt SM OC-3 LR-1/STM-1 L1.1

Same functionality as for Opt SM OC-3 LR-1/STM-1 S-1.1 in R1A00 with modifications for this board ( < 40km)

Line Interface Optical Unit Opt SM OC-3 LR-1/STM-1 L1.2

Same functionality as for Opt SM OC-3 LR-1/STM-1 S-1.1 in R1A00 with modifications for this board ( < 80km)

Page 16 of 41

Evolution Metro Release Notes

SW Download

Patch support

Frame/Plug-In Units

4*64kb/s Auxiliary Unit

Release R10C00

Configuration of each individual 64kb/s channel Setup of channel and direction for each 64kb/s channel Insertion/extraction of the 64k/s traffic into the right timeslots on the OHC-bus PRBS and Looping Alarms Inventory: Production data and SW version

RSSI

Time series

On Web

Cumulative

On Web

Page 17 of 41

Evolution Metro Release Notes

Release R10C00

In addition the following Release 3A functionality of the Evolution Series SW is supported: Main Functionality System Frequencies

Includes XPAND

Description 75xE1 [155.520 Mb/s] 1+0, 1+1, HSB with 1 antenna direction

26 GHz 38 GHz

Frame/Plug-In Units

2 Frame Connection Panel Unit

Support for interconnection between plug-in units in the 2 frames

PDH Interface 25*E1 Unit

Configuration of ports Test: Looping Inventory: Production data and SW version Alarms

GB Ethernet Interface (GIU)

QoS

1x10/100/1000BaseT + 3x10/100BaseT + 1000BaseX(SFP)

Half/full duplex configuration

Enable/disable of Ethernet ports LLF (Link Loss Forwarding) enable Flow control enable SDH/SONET Mapping selectable Far end and near end loops Monitoring of error rates RSSI

Configuration

Time series

SNMP support

Cumulative

SNMP support

License Manager update

LM Branding support License pr. ODU

Page 18 of 41

Evolution Metro Release Notes

Release R10C00

In addition the following Release 3B functionality of the Evolution Series SW is supported: Main Functionality

Includes

Description

System

XPAND

20xE1 [41.984 Mb/s] 40xE1 [83.264 Mb/s] 50xE1 [103.936 Mb/s]

METRO

Add/Drop terminal in 2 antenna directions. E1 and DS3/E3 interfaces. 3+0/4+0

Radio

New radio capacities supported

SRM 5,6,7

Frame/Plug-In Units

SDH/SONET Digital Cross Connect (DXC) Unit

Configuration of data in all 4 directions of DXC (in and out) AU3 and AU4 configurations Mapping configuration (VC4, VC3, VC12) MSOH termination / geeration SNCP SETS support

Interface 12*E1 Unit

Configuration of ports Test: Looping Inventory: Production data and SW version Alarms

Interface 3*DS3/E3 [34/45] Unit

Configuration of ports Configure the interface specific parameters such as cable length Test: Looping Inventory: Production data and SW version Alarms

Alarm & Control Auxiliary Unit

Configuration and control of the 4 analogue inputs Configuration and control of the 8 alarm inputs Reporting of the 8 alarm inputs Configuration and control of the 4 relay outputs Page 19 of 41

Evolution Metro Release Notes

Release R10C00

In addition the following Release 4A functionality of the Evolution Series SW is supported: Main Functionality

Includes

Description

System

XPAND

Terminal Mix of: E1 and SU-FE T1 and SU-FE as described in Grand Plan

Frame/Plug-In Units

Interface 8*T1 and 16*T1 Units

Configuration of ports Test: Looping and PRBS Inventory: Production data and SW version Alarms

GIU

SW add-ons: Port Mode – MAC switching Graphical Statistics and Performance

SU (SU-FE)

E1/T1 mapping (XPAND) Wayside mapping (METRO)

SNMP New Configuration MIB

Page 20 of 41

Evolution Metro Release Notes

Release R10C00

In addition the following Release 4B functionality of the Evolution Series SW is supported: Main Functionality

Includes

Description

System

XPAND

Traffic Node, 2 to 4 directions (1 or 2 IFUs)

METRO GIU

T1 in OC-3 mapping.

Frame/Plug-In Units

VC-12/VT-1.5 SDH/SONET mapping with DXC interface LCAS (Link Capacity Access Scheme) up to 4xSTM-1 using one of the following mappings: up to 4VC-4/STS-3c SPE or up to 12 VC-3/STS-1 SPE 1xSTM-1 using one of the following mappings: up to 63 VC-12/84 VT1.5 Not mixed mapping on GIU. Interface to DXC unit

E1/DS1 Wayside Auxiliary Unit

DS1 or E1 setting Configure the cable specific parameters such as cable length for DS1

DXC

RPS

1+1/HSB

Synchronization source using tributary port (E1/DS1) GUI Improvements

Page 21 of 41

Evolution Metro Release Notes

Release R10C00

Functionality introduced in R5A00 Main Functionality Frame/Plug-In Units

Includes Line Interface Optical Opt SM OC-12 IR-1/STM-4 S-4.1

Description Laser On/Off control Alarms Test: Looping and PRBS Pathtrace DCC Inventory

RIU 311MB/s

Supported in the following terminal types: 1+0 2+0 HSB 1+1 Alarms Inventory

DS3/E3

Management

SU Ethernet

Mix of DS3 and E3 on a plug-in board. System configured as SDH. Inband Management supported on terminals (SU-NMS traffic transported with user traffic on SU Ethernet)

Page 22 of 41

Evolution Metro Release Notes

Release R10C00

Functionality introduced in R5B00: Main Functionality System

Frame/Plug-In Units

Includes 2+0 HSB DBB

High Power XVCR/ODUs Line Interface Optical Opt SM OC-12 IR1/STM-4 S-4.1

Description 2+0 HSB DBB system with XPIC support

Support for High Power XVCR/ODUs Support for several STM-4 LIU simultaneously Support for several antenna directions

Functionality introduced in R5B01: Main Functionality

Includes

Description

System

XPAND

PDH circuit protection (SNCP) with LIU (E1/T1) source

Radio

SRMs

Transmit power level update

Page 23 of 41

Evolution Metro Release Notes

Release R10C00

Functionality introduced in R6A00: Main Functionality

Includes

Description

System

METRO

Maximum 8 unprotected channels 5+0 to 8+0 Maximum 7 protected channels 2+1 to 7+1 Low priority Traffic on n+1 systems

METRO Line Multiplexer

Multiplexer (node/line terminal without RIU/radios) using DXC unit

Frequencies

10 GHz

Radio

Branching system

GUI for filter selection. Diplexer or RF channel filter

Space Diversity

Combiner Space Diversity

Added GIU features

LAN Ports to WAN mapping (up to 4 VC groups)

Support for changed and new Hardware

Gigabit Interface Unit / FNZ5695B-T IFU Basic Frame / FUBU6325B-T (Universal IFU)

Frame/Plug-In Units

Supervisory Unit / FKCN5551C-T 4 shelf assembly /UBM6408. Inventory support

Management

SNMPv3 nera-global-reg.MIB

Security and authorization Cold start time stamp Support for protection channel

Web

GZIP file compression support

Page 24 of 41

Evolution Metro Release Notes

Release R10C00

Functionality introduced in R6B00: Main Functionality System

Includes METRO

Description METRO Multi Terminal, 3 & 4 ODU directions (1+0/HSB/1+1) in 2 IFUs METRO Multi Terminal, 3 & 4 ODU directions (1+0/HSB/1+1) with DXC unit in 2 IFUs

Frame/Plug-In Units

Added GIU features

T1 interface

Support for VLAN routing AMI support

Functionality introduced in R6C00: Main Functionality

Includes

Description

Frame/Plug-In Units

Added GIU features

Support for simultaneous use of two Gigabit LAN Ports. (LAN Port 4 and LAN Port 5) Note! Applies to Switch Mode only.

Page 25 of 41

Evolution Metro Release Notes

Release R10C00

Functionality introduced in R7A00: Main Functionality System

Includes METRO Larger Systems (> 2 IFUs)

Description Multi Terminal, 3 & 4 ODU directions (1+1/HSB/2+0) Full scale, 4 antenna directions with DXC Frame METRO Traffic node, 3 ODU directions with DXC unit Node configuration with OC-12 / STM-4 interface (STM4 /OC-12 Mux) Line terminals with DXC Frame DXC frame with n+0/n+1 terminals

New SRMs

SRM32: 28xE1 + SU-FE [~59 Mb/s], 64TCM - 14 MHz SRM28: 64xT1 + SU-FE [~100 Mb/s], 16QAM - 40 MHz SRM30: 14xT1 + SU-FE [22 Mb/s], 128TCM - 5 MHz

Radio

High Power ATPC 311Mb/s Web

RPS

Performance

Switch sections

HP ODU using lower order modulation (4 - 32 level) ANSI requirement: MAX Power 5 minutes alarm 311 Mb/s ODU, 5-15G frequency plans Radio placement in Long Haul systems Counting of Switching events on web and SNMP  PS Request Count  PS Actual Count  PS Actual Duration  PS Request Service Affecting Duration Support for 3 and 4 switch sections (1+1/HSB)

Page 26 of 41

Evolution Metro Release Notes

Frame/Plug-In Units

Added GIU features

Release R10C00

Configuration with DXC frame. Mapping GIU or STM-4/OC-12 ”buses” towards line and/or radio

SDH/SONET Digital Cross Connect (DXC) Frame

Configuration of 8 ports of the DXC Frame. X-connects of VC-4/VC-3/VC-12 (VT-1.5/STS-1/STS-3c)

Electrical and Optical STM-1 interface boards

OHC bus (64kb/s and WS) support towards line (STM-1/ OC-3)

Motherboard (IFU)

Support for changed and new Hardware

SOH bypass (64kb/s between radio/line directions)

DXC Frame SDH/SONET support - (FUBU6663A-T) New 5 shelf assembly (UBM6409). Inventory support (required for DXC Frame unit) Power and Synch Board (for power feed to DXC Frame unit)

Management

Web

Housekeeping

Local time support (only on web, alarms/performance timestamps presented on SNMP interface will still be GMT) New advanced METRO configuration system, for flexible interface configuration (MDS configuration)

Page 27 of 41

Evolution Metro Release Notes

Release R10C00

Functionality introduced in R8A00: Main Functionality

Includes

Description

System

Frequency

Remote Frequency Setting

XPAND

STM-1/OC-3 interface on XPAND

METRO

311 Mb/s Support in 1-4 Antenna directions (1+0,1+1,HSB,2+0) N+0 in 1 antenna direction DXC unit and DXC Frame support for all configurations with 311Mb/s ODU Mix of antenna directions with 155Mb/s and 311 Mb/s ODU

Management

OSPF/Stack

Updated router and IP stack SW

SNMP

Table with remote/neighbour terminals, RSSI for Space Diversity

Https

SSL (Secure Socket Layer)

Web

Separate WEB page for configuration of station name, terminal name and antenna direction names. Web generated status report/file for e.g. Customer Service feedback RSSI for Space Diversity

Functionality introduced in R8A02: Main Functionality

Includes

Description

Frame/Plug-In Units

Radio

Radio Reset Button

Management

Configuration

Added option for clearing all configuration including passwords, IP and Network settings.

Internet Explorer 6

Internet Explorer 6.0 is not supported warning

Page 28 of 41

Evolution Metro Release Notes

Functionality introduced in R9A00: Includes Main Functionality FKCN5551D-T (SU) Frame/Plug-In Units

GIU XPAND DXC Frame and Unit

Release R10C00

Description Support for 4 FE ports on SU VLAN QoS Support for individual MAC learning per VLAN Support for new enhanced Direct Ethernet Mapping for FKCN5551B-T and FKCN5551C-T J1 (Pathtrace) B3 and G1 support Received Signal Label Status

DXC Frame and Unit PWIU

SNCP Manual Locked Switching Support for adding extra Power Interface Unit (-48V)

Radio Radio System Management

METRO Log Licenses Configuration Fault WEB SNMP SNMP

Functionality introduced in R9A01: Includes Main Functionality XPAND Frame/Plug-In Units

Radio

Support for ACM Ready Radios Manual Power On/Off Repeater Configuration (RIUs back to back) Element History Log Support for Licenses file Added option for backup restore with cold start Added alarm for WEB logon for reporting on Netmaster RMON counters statistics on WEB Added support for analogue measurement for Alarm and Control Unit (FKN5674A-T) Changed format on reported SW revision

Description Support for new enhanced Direct Ethernet Mapping for FKCN5551D-T. (Support for new enhanced Direct Ethernet Mapping on FKCN5551B-T and FKCN5551C-T was introduced in R9A00) Support for 4GHz channel plans

Page 29 of 41

Evolution Metro Release Notes

Release R10C00

Functionality introduced in R9B00: Includes Main Functionality

Description

Frame/Plug-In Units

Support for 150Mb/s on FKCN5551D-T in XPAND systems with Direct Mapping

SU Ethernet

Faster Link Loss Forwarding (LLF) signalling in XPAND systems with Direct Mapping

System

Management

GIU and SU-D

Name / information field for Ethernet ports.

Radio

IFU-ODU cable monitoring with alarm and error pulse reporting

RIU

Changed RIU ADC overrange alarm to a more informative name: IF CABLE INPUT LEVEL HIGH

XPAND

SRM30: 14xT1 + SU-FE [~20-25 Mb/s], 128TCM - 5 MHz not supported

RADIO

Support for different bandwidth on different radio channels

METRO

System configurations: 3+0/4+0 Double Terminal incl. mode with 2 antenna directions in same IFU

Space Diversity

Updated layout on WEB

RPS

Option for standalone RIU for ch P in IFU 1 in n+1

WEB

Support for Internet Explorer 8

WEB

Temperature reading for IFU Basic Frame

WEB

SNR (Signal to Noise Ratio) monitoring for radio hop Link Error monitoring with cumulative counter for radio hop

SNMP

Default enabling of SNMPv2 SNR (Signal to Noise Ratio) for radio hop Temperature reading for IFU Basic Frame Fault trap throttling Direction and event type for alarms Updated config MIB Link Errors with cumulative counter for radio hop in performance MIB

OSPF/RIP

Unnumbered interfaces

Alarms

Direction and eventType for alarms Page 30 of 41

Evolution Metro Release Notes

Release R10C00

Updated All alarm WEB page Updated Blocked alarm WEB page License

License Request File option to get permanent licenses when replacement licenses are used Admin user can now delete licenses Updated Licenses WEB page showing all licenses

Configuration Backup

Updated Configuration Backup WEB pages Removed Configuration Backup and Restore using Flash on SU

Security

Configurable logout timer to user settings Updated automatic log out functionality to also log out when automatic polling is activated

Functionality changed in R9B03: Includes Main Functionality WEB Management SNMP

Description SNR monitoring for radio link removed. SNR monitoring for radio link removed.

Page 31 of 41

Evolution Metro Release Notes

Functionality introduced in R10A00: Includes Main Functionality System System Radio Radio

Frame/Plug-In Units Management

IFU Basic Frame FUBU6325C-T WEB WEB WEB

WEB

SNMP SNMP

SNMP

Fault

Fault

Performance Management Configuration

Release R10C00

Description Add support for filter compensation for 28MHz filter settings in ACAP mode. SW support for 32GHz frequency band. Support for changing SW package from Evolution Series XPAND-IP to Evolution Series XPAND/METRO. Support for Evolution Series XPAND-IP compatible IFU Basic Frame FUBU6325C-T Updated WEB layout including RF levels and remote status at the homepage. Configuration of element Information (free text fields) and coordinates (location) for element. Performance: Link thermometer including time series (72 hours) and cumulative statistics with RF input level and error pulses for each radio channel. Performance: Analogue time series are continuously monitored. Configuration of element Information (free text fields) and coordinates (location) for element. Performance: Link thermometer including time series (72 hours) and cumulative statistics with RF input level and error pulses for each radio channel. Performance: Additional Ethernet statistic parameters for NetMaster. Support for selected parameters in IF-MIB and ifXTable. Fault Log: Present newest log entries first. Fault Tables: Updates to column presentation sequence. XPAND: Added alarm ” NO CAPACITY CONFIGURED” (in system with Ethernet configuration) and ” PAYLOAD MISMATCH”. G.826 calculations for link errors per radio channel. Management Traffic IP classification (DSCP Priority Tagging). Restore of configuration backup includes licenses. Page 32 of 41

Evolution Metro Release Notes

Functionality introduced in R10A01: Includes Main Functionality 13 GHz Long Haul System Frame/Plug-In Units

Support for new hardware

Release R10C00

Description Support for 13GHz Long Haul branching systems. Support for Shelf-Assy 4 IFU UBM6408B that is METRO and XPAND-IP compatible. UBM6408B requires IFU-C: FUBU6325C-T.

Functionality introduced in R10B00: Includes Main Functionality Radio Frame/Plug-In Type C XCVR Units Radio – XCVR Main Board FUNF5898B-T Radio Interface Unit FDM5559D-T FDM5559E-T Management

GUI

Description Support for type C XCVR for Long Haul systems Support for new XCVR Main Board

Support for new RIUs Cabled XPIC will be supported in a later SW release. Terminal ID A field for the terminal article code is added at the Element-Terminal ID page.

WEB

Internet Explorer Version 9 Mozilla Firefox Version 4-8

License Management

Support for generation of temporary installation licenses.

3.5 New Functionality in R10C00 Main Functionality Frame/Plug-In Units

Includes Radio Type C XCVR Radio Interface Unit FDM5559F-T RIUs

Description Support for type C XCVR for Long Haul systems for 5 and 11 GHz Support for new RIU The SNR status for each channel is added to the signal monitoring page for corresponding RIU. Page 33 of 41

Evolution Metro Release Notes

Release R10C00

4. Bugfixes IN R10C00 4.1 XPIC Polarization tooltip is configurable Customer can set the tooltip to match actual XPIC settings..

4.2 Routing of STM-4 and DXC The routing is now a manual operation and not automatic.

4.3 Pattern Loss and errors on STM-4 board Fixed problem when some of the channels on the STM-4 board are used for add/drop and some are not.

Page 34 of 41

Evolution Metro Release Notes

Release R10C00

5. INSTALLATION OF R10C00 PACKAGE 5.1 Procedure Note1: Upgrade from R1x or R2x Do not upgrade from Release1 or Release2 on a running system. Upgrade from Release3 and later is OK. The SW package prior to Release3 contained a different licensing scheme. Upgrading from Release1 or Release2 package to any later release versions will cause traffic down. New licenses have to be installed in order for the system to come up and operate normally again. Installing the licenses when traffic is down, must be done by local or external (not across the link) management connection.

Note2: Traffic interruptions Updating to R10C00 from other SW revisions cause traffic interruption. The following functionality is affected: All Evolution Systems.

Page 35 of 41

Evolution Metro Release Notes

Release R10C00

Download Procedure: Use Web GUI or Netmaster to download the software package to the element. You need Admin privileges to be able to download the new package. For Web GUI; Select Configuration  Software and the SW Download tab. Select the “SW-EVOLUTION-RELEASE-APP-R10C00_1.tar” file and press Download button. The package contains five .tar files and the GUI will prompt for new files as needed.

Figure 1: Downloading tar file Depending on what versions is on the active and inactive, the software installer will minimize the need for transfer between web client and element. If the software is not complete after first tar, you have to choose the second tar file. If the package becomes complete on the element, you are allowed to switch the software. Use the SU SW Versions tab and click on Switch Software tab. The SU will restart, so the connection to the WEB server is lost. You should be able to log in again after a short while.

Page 36 of 41

Evolution Metro Release Notes

Release R10C00

Please note that with SW version R4Bxx or later information about the current SU is stored in the IFU Basic Frame. As a result the SU has to be activated after the first restart running R4Bxx or later. Press the Set Current SU active button displayed in figure 2. Also, the cache must be cleared after SW upgrade. If the cache is not cleared, the web pages may not show correct information. Please refer to handbook for a description of how to clear the cache in different browsers.

Figure 2: Activating the SU after SW switch

Page 37 of 41

Evolution Metro Release Notes

Release R10C00

Figure 3: Status after software switch

Page 38 of 41

Evolution Metro Release Notes

Release R10C00

6. KNOWN PROBLEMS 6.1 OSPF Router OSPF Routing may be inconsistent when CityLink, InterLink and CompactLink equipment is used in the same OSPF system as Evolution Series terminals. Workaround: Do not configure the InterLink or CityLink to be a designated router. Use static routes between the Evolution Series terminal and InterLink or CityLink terminals.

6.2 XPAND Upgrade from R4A00 Unused XPAND PDH channels in R4A (or earlier revisions) results in enabling of unused ports and thus AIS and LOS alarms after SW upgrade.

6.3 Memory Limitations Supervisory Unit FKCN5551A-T and FKCN5551B-T In FKCN5551A-T and FKCN5551B-T there is a memory limitation so that maximum system configuration is within 2 IFUs. In large configurations within 2 IFUs using 2 FNZ5695A-T/ FNZ5695B-T, the user may experience a problem when trying to configure several auxiliary boards. Workaround: Use Supervisory Unit FKCN5551C-T or FKCN5551D-T in systems with large configurations.

6.4 Ethernet Configuration Mismatch Gigabit Interface Unit FNZ5695A-T This problem is related to the Gigabit Interface Unit FNZ5695A-T Internal lock-up in the equipment may occur if equipment Ethernet Port with Auto Speed is connected to an external Ethernet port with fixed speed/duplex 100M Full or 10M Full. Management and User Ethernet traffic will be lost. Affected unit; Gigabit Interface Unit needs power up restart to recover. Workaround: Use the same setting both for the Evolution Series terminal and the equipment connected to it. Use either Auto on both sides, or the same fixed setting on both sides. Page 39 of 41

Evolution Metro Release Notes

Release R10C00

6.5 Software downgrade to R6B02 or earlier revisions – Gigabit Interface Unit This problem is related to the Gigabit Interface Units FNZ5695A-T and FNZ5695B-T. Inconsistent behaviour can occur when downgrading to R6B02 or earlier revisions with two Gigabit LAN Ports (LAN Port 4 and LAN Port 5) enabled. Workaround: Disable one Gigabit LAN Port (LAN Port 4 or LAN Port 5) before downgrading.

6.6 Software downgrade to revisions earlier than R7A00 Please note that if the system is configured with R7A00 or later revision, and then an earlier SW revision is installed, the system configured with R7A00 or later revision will be lost. This will happen even if the configuration is supported in this earlier SW revision. When switching back to R7A00 the configuration will be restored again.

6.7 Access rights on DXC unit and DXC Frame Signal label information and SNCP status information is available for user with access rights MASTER and ADMIN. Not presented to users with PASSIVE or ACTIVE access rights.

6.8 Upgrading to N+1 systems from earlier releases than R8A00 The RPS-ORDERWIRE alarm may appear after an upgrade to R8A or later. Workaround: Run through the housekeeping wizard and the system will be reinitialised so that this alarm disappears and the orderwire channel is operational.

6.9 Memory Limitations DXC Frame Supervisory Units FKCN5551A-T and FKCN5551B-T do not support DXC Frame due to a memory limitation on these units for SW version R8A or later.

6.10 DXC Frame SETS status and alarm reporting. Incorrect alarm reporting from the SETS function on the DXC Frame may occur. The event log may contain an event sequence with SETS_SYNCHRONISATION_PRIORITY1 cleared /raised, typically for one Page 40 of 41

Evolution Metro Release Notes

Release R10C00

second. The SETS functionality itself is not affected, only the alarm status reporting.

6.11 Upgrade of Supervisory Unit from FKCN5551A/B/C-T to FKCN5551D-T. After configuration download to FKCN5551D-T with configuration uploaded from FKCN5551A/B/C-T, the user must reconfigure the Ethernet functionality on the supervisory unit.

6.12 Housekeeping wizard – Indoor Radio Placement page A minor fault on the indoor radio placement page has been detected. Moving radios on the GUI should be avoided. A bugfix release is in process.

Page 41 of 41