CUADRO DE CONVENCIONES REFERENTE A LOS COMPONENTES DE UN CUARTO DE TELECOMUNICACIONES

CUADRO DE CONVENCIONES REFERENTE A LOS COMPONENTES DE UN TRAZADO DE CABLEADO HORIZONTAL

CUADRO DE CONVENCIONES REFERENTE A LA NUMERACION EMPLEADA PARA RELACIONAR LAS AREAS DE TRABAJO

CUADRO DE CONVENCIONES REFERENTE A LOS COMPONENTES DE UN AREA DE TRABAJO

CUADRO DE CONVENCIONES REFERENTE LOS SISTEMAS DE SEGURIDAD

CUARTO DE EQUIPOS Backbone Cables To

Equipment Cable Ducts

Backbone Cables From Building Entrance Area

System Common Equipment

Building Distribution System Common Equipment Cabling

Distribution Cross-Connect a101.126a S

METODO DE LA MANGA

Wall Strap

Cable Tied To Steel Support Strand

Sleeve

METODO DE LA RANURA Cable Clamp

Floor Bracket

Slot

Cable Clamped To Steel Support Strand

METODO DE CONDUCTO

Main Backbone Conduit Extending Through Basement Area

METODO DE TRASPORTE DEL CABLE Cable Rack

Backbone Cable

METODO DE SALIDA DE INFORMACION

Horizontal Telecommunications Closet Cable

IO IO

IO

Information Outlet (IO)

METODO DE ZONA

From TC

25-Pair or bundle of 4-pair Horizontal Zone Cable

Consolidation Point

IO

4-Pair Extension Cable

4-Pair Extension Cable

IO

METODO DE CANAL Header Raceway For Communications Wiring

Communications Wiring

Lateral Raceway For Communications Wiring

Power Cable

Lateral Raceway For Power Wiring

Header Raceway For Power Wiring Jack

a101.120a S

METODO ATRAVES DEL MUEBLE

a101.121a S

DUCTOS POR DEBAJO DEL PISO

Outlet Box For Jack

To Backbone Closet

Outlet Box For Power

Access Plate

DUCTOS PROYECTADOS ENTRE DOS CUARTOS DE TELECOMUNICACIONES 300 ft (91m)

Core Area 200 ft (61m)

Telecommunication Closets

a101.02b S

DUCTOS DE CONCRETO POR EL PISO

Cell For Communications Wiring

Header Duct With Removable Plates

Cell For Electrical Wiring

METODO PISO FALSO

Floor Plates Removed To Gain Access To Cable

Locking Pedestal

METODOS POR DEBAJO DEL PISO

Flush-Mounted Satellite Cabinet IOs

IO

a101.125a S

METODO BASE DE DISTRIBUCION

SATELLITE CABINET

CONDUIT

BASEBOARD RACEWAY FRONT PANEL

POWER AND COMMUNICATIONS CABLE (SEPARATED CHANNELS BY tab2.# PARTITIONS)

METODO DE TERMINACION DEL DUCTO EN EL AREA DEL SOTANO

When Possibility Exists That Metallic Conduit Will Come In Contact With Building Reinforcing, Insulation Around Duct Is Necessary. Ground Level

Provide 4″ (102 mm) Recess When Possible

Coupling 2X Diameter Of Conduit

Inside Wall

Concrete Wall Footing

Duct Extended to Undisturbed Earth to Avoid Duct To Pole, Shearing Manhole Or Property Line

Duct Section Placed Through Wall At Time Of Construction Reinforcing V-Cut Trench or Shored Straight Trench

a101.44b S

FORMA DE PENTRACION DEL DUCTO AL PRIMER PISO

Plywood For Terminal Or Splice Location

Ground Level

8″ (203 mm)

Foundation Slab

24″ Min. (610 mm)

To Alternate Location

Radius Adapter

Minimum Drop of 1 Inch per Foot