P - 14
CLLI
Cal-Lab Lightning Isolators – Product Brief
LIGHTNING ISOLATORS
1. Know what your equipment is linked to (such as: Power / TV-Antenna / Satellite Dish / Analog Or Digital Telephone-Line / Networking) 2. Decide by picking one or more MDLI or CLLI suitable below. CLLI model SC0039 NILI9920F SL-AR(3A)* MDSC0039 SL-AR(5A) SL9602F**
Description & features c/w 13A plug top, 10cm cable and 1 socket outlet. Fused version is optional. <*SL-AR(3A) – max. 3Amp. for fridge only> c/w 13A plug, 1.5M cable + 1 socket outlet & EARTH terminals. Fused version is optional. **F = EMI Filter
For what? For power supply of air-cond / fridge / washing machine / microwave oven Used with multiple outlets at power supply of multi-input equipment set-up.
SL-MS2+3 SL-MS4 (customized) SL-MS4+6 Trinity-TP
c/w 13A plug, 1.5M cable, 2x13A & 3x2-pin outlets & EARTH points. Fused version is optional. c/w 13A plug, 1.5M cable + 10 outlets or 7 outlets & EMI Filter, with EARTH points. Fused version is optional. C/w terminal screws & fuse, for DIY interface into Power cord. MD-SC3C for professional use. AC/DC 12 or 24V feed-through LI / with or without DC-jack & socket Twisted-pair or screw-on in-out for MD-4Ccu (Data-5V) / MD-4Ccu(+12V) / (+ 24V) / (CB-36V) MD-8Ccu with RJ-45 in-out c/w one input socket & one output plug in RJ-11 format & Earth wire c/w 1 plug & 1 socket for DSL in-out & one Analog output socket in RJ-11 + Earth wire c/w Power + RJ-45 in-out using pins 1, 2 & 7, 8 + Earth wire c/w one input socket & one output plug in RJ-45 format & Earth wire c/w one input socket & one output plug & Earth wire c/w 2 input RF sockets & 1output plug & Earth wire. MDTV-cu Decoder or Video extender Combination models c/w 1.5M cable & one 13A power outlet + FC-connectors + tel-line & antenna isolators. (sold without FC-cable) Combination CLLI c/w 1.5M cable, 13A Plug & socket + RJ11 in-out sockets. SF9812 c/w replaceable SKPX-DSL/AR or D c/w power & 2 X RJ45 sockets
Used for power supplies of multiple equipment set up.
SC9517 MD-SC3C DCJ-cu DCJ-cu+E MD-4Ccu (in 4 versions) MD-8Ccu SP9201D / AR SP9201-DSL SP9201-DAF SD-9623cu (RM93) SLAN-1236 MD-BNC MD-FC MDTV9922 MDTV-cu SFTV9822-FC SFTV9622-FC SF9512-D / AR SF9512-DSL SF9812 SD-4C or 8C STV9511 MLPX series
TRINITY series PLC-CLLI Power-line network
Combination CLLI c/w 1.5M cable, 13A Plug & socket + PAL-RF sockets in-out. Made up of BX / BB / SKPX-modules for TRUNKline or EXTENSIONS Combination MODELS & Multiple Sockets power outlets. Example – A-V Pack MS3+3 or I-T Pack -MS4+3 or SFTV9622FC-MS2+3 or SL-MS2+3 Twin-Pack (10 outlets) Power-line Network or PLC-adaptors can now share a power outlet with connected equipment, improve connection-rate & safe from lightning.
General Guide
CLLI Versions
Typical combinations in Home or Office From Telco
Possible sources of danger from lightning: SATELLITE / TV-ANTENNA / TELEPHONE LINE / POWER LINE Parallel phone-line Antenna Booster
Important:
Via Micro-filter
All interconnected equipment must only draw power supply from one & the same CLLI (except for Antenna Booster)
SFTV series
Used for power supplies of multiple equipment set up.
2 SP9201-DAF 1
Add-on to existing equipment power cord or extension cord. For Alarm sensor / DC power. Used at Video door-phone / keypad / C-bus. RS-232 Adapter For Analog telephone or DSL version for DSL modem CLLI c/w DSL line Filter-Splitter replacing ‘Micro filter’ For 2-pairs Data / leased lines (pins 1278 or customized). For networking equipment using UTP cable at HUB or Router. For co-ax cable with BNC or Fconnector For TV antenna mixer. May be used as a splitter. For Satellite TV receiver with Modem, such as astro. Used with multiple trailing sockets. For Fax/MODEM, PC, Cordless phone. SF9512-DSL for broadband/ISDN For DTE using UTP – 8 wires or 4 wires at RJ-45 For equipment set-up including TV without Satellite dish For KEY-PHONE / PABX For equipment set-up needing multiple power socket outlets. Thus eliminating the need for trailing socket outlets. NILI-PLC / NILI-PLC-TWIN / NILIPLC-TRINITY for reducing RFnoise & improving connection-rate
3
Satellite Decoder Plasma-LCD-TV DVD / VCD Amplifier (All Power from 1-CLLI only) Choice of CLLI versions: • SL-SC – for power • SP series – tel-line • SF – power + tel-line • MD-BNC – CCTV • SLAN – network cable • STV – power + TV
0612 Specs Connection Current sensor? Clamping Voltage Isolation Means Potential Limit
• • • •
SL-MS2+3 FAX-machine And / or Cordless-phone SF9512DSL
SD-4C Network PC Printer ++
Power section 13A / 3-pin P&S NA 275Vrms Weak-links ~430V to Earth
Tel-line version-D RJ-11 sockets Yes ~150V Resistive fuse ~470V to Earth
DSL-modem Router-WIFI PC-Server ++ (Add SLAN1236)
TV antenna PAL-sockets NA NA C-coupling 0V to Earth
Satellite Cable F-type NA NA Reverse-means 0-V to Earth
Note: CLLI are sold with Lifetime Service Warranty – see LLSWA Correct installation is vital for equipment & USER safeties! Terms & Conditions in WARRANTY CARD & Thank-you note. Technical Assistance / Important Info in: www.cal-lab.com
SPECS, Prices & CONDITIONS subject to change. Refer to: www.cal-lab.com For help, call / FAX: 06-9517680 / 03-77268680 Email:
[email protected] Service centre: HQ – 30 Lrg. Kurau 9, Tmn Sg Abong, 84000 Muar, Johor, Malaysia. Non-tampered & lightning-damaged CLLI can be exchanged @ RM25 or less!
Prod. Specs & Install
CLLI
Cal-lab Lightning Isolator
CAL-LAB Lightning Isolator General Product Specifications
CLLI is most effective when correctly used at each equipment setup to create a SAFE-island
At Power Line: (Works best for 220V supply. Versions for 110V available by request) Description Specs Note Operating Voltage 100~250 Vac (As Specified) Let-Through Voltage ~ 275 Vrms (Typical) Clamping Voltage ~430V Isolation Level Choice of 10A / 5A Fuses optional Static Potential Limit ~470V (To Ground Means) Connectors / cable 13A-3 pins or 5A-2 pins / 3-core AC As specified cord, 1.5M long or customized At Telephone Line: (Conform to accepted standards employing RJ-11 or RJ-45) # Description Specs Note 1 Clamping Voltage ~150V or whenever over-current is DSL customized version detected by unique patented circuit clamps at 230V 2 Isolation Delay Depends on surge magnitude After circuit activated 3 Current Limit 100mA (AR version) / <500mA (others) DSL customized version has < AR-version not for caller-ID > no current sensor 4 Response Time At electronic speed of components After circuit activated 5 Static Potential Limit ~470V (To Ground means) DSL customized version at <600V to Ground At LAN Cable: (Isolation-links at each cable conductor will allow up to 1A) # Description Specs Note 1 Clamping Voltage ~9Vp-p for SLAN / SD-8C / SD-4C / MD-BNC for CCTV only MD-BNC series (customized for LAN) 2 Static Potential Limit ~470V to Ground means or customized 3 Added Impedance ~20 pF (<10 pF can be customized) May cause loss in speed At TV Antenna Cable: (For co-ax cable & PAL-RF connectors) # Description Specs Note 1 Isolation Capability 0-mA (DC Isolation Up To 6-KV) or 2-KV to Ground 2 RF Signal Loss Negligible 3 Let Through Current 0-mA Up To 6-KV DC 4 Static Potential Limit 0-V To Ground Means. At Satellite Dish Cable: (For co-ax cable & F-type connectors. Specs not applicable to non-Isolation version. LNB Protection is not attempted) # Description Specs Note 1 Signal Loss 1 ~ 5% (by added cable & connectors) Full Isolation version 2 Isolation Means Built-in Isolation circuits Cause ~1% loss 3 Let Through Voltage ~20V ac/dc Let through current: 1A 4 Static Potential Limit 0V To Ground Means Full Isolation version # 1 2 3 4 5 6
Patent Reference • U S Patent #5675468 • Malaysian Patent # 111139-A • China Patent #Zl 95 1 18324.9
• • • • • •
Test Reference Sirim Test #EMCL-M0001 Sirim Test #EMCL-99011 Sirim Test #2000EMC020 Sirim Test #2000EMC080 IVAT Test (1998 Sirim Test #2004EMC098
Type Approval SAFE PHONE TAJC/04A/0992/S TJP9633 LAEA/22A/0599/M SFTV LAEA/23A/0599/M SF9812 LAEA/24A/0599/M MLPX9708 LAEA/25A/0599/M SF9512 LAEA/26A/0599/M SD9623 LAEA/27A/0599/M • Others (On Request) • • • • • • •
<Specifications & Features subject to change without notice> Latest Specifications or details in www.cal-lab.com Call / FAX 06-9517680 or 03-77268680 Email:
[email protected]
CLLI
STEP-BY-STEP INSTALLATION FOR COMPETENT BEGINNERS Lightning can arrive any time! Wear rubber shoes & turn OFF power while touching any cable or connector (even though insulated)!
A. Note down all existing connections with a sketch 1. Note each power supply connection. 2. Note each connection to the telephone line (if any). 3. Note each connection to the TV antenna (if any). 4. Note each connection to the Satellite dish (if any).
B. Turn off the power supply 1. Each of the power supply connections you have observed above should be switched ‘off ’ and disconnected from the wall outlet. 2. If each of the power supply connection is connected to one multiple extension-block, then just disconnect the plug top from the ‘wall’ or initial supply outlet. C. Read the recommended installation for lightning isolator 1. Be sure you understand the instructions. 2. Be sure you can identify each item mentioned. 3. Be sure you can identify each connection point mentioned. D. Step-by-step installation, if applicable (remember there is danger any time). 1. With the power supply remaining at ‘OFF’ position, and all interconnecting equipment at ‘OFF’ position, connect the multiple extension-block input plug to the output socket of the CLLI. 2. Insert the plug top of the CLLI to the wall outlet, but DO NOT turn ON power yet. (Important – This step must be carried out for added personal safety) 3. Squeeze and remove the telephone line connection at the equipment; then insert the same plug (RJ-11) into the ‘IN’ socket for tel-line at the CLLI. 4. With the RJ-11 plug-to-plug cable provided, connect one end to the ‘OUT’ socket at the CLLI and the other end to the equipment where you have earlier removed the plug from. 5. Slightly rotate and remove the TV antenna cable from the equipment and insert it onto any one of the RF-sockets at the CLLI. Then reconnect the cable from the other RF-socket to the equipment ‘ANT’ input. 6. Unscrew the F-connector cable (leading to the Satellite dish) from the equipment and fasten it to any one end of the F-connector at the CLLI. With the F-connector cable or Twist-On-Plug provided, reconnect between CLLI and the equipment. 7. Check to ensure POWER to each interconnected item is taken via the same CLLI and every ‘outside connection’ (such as to telephone line, TV antenna and/or Satellite dish) is also via the same CLLI. (LAN cable must be isolated & grounded) 8. When everything is correct, switch ‘ON’ the CLLI power supply at the wall outlet and switch ‘ON’ the equipment one-by-one. (Otherwise, the CLLI may blow!) * Get expert help if you encounter any problem * .Specifications & Prices subject to change. Latest Technical Assistance or details in www.cal-lab.com Call or fax CAL-LAB at 06 9517680 for advice or Email:
[email protected]