KX6 + 1P 0.34 + 2×0.75
170205-00
Update A C1
elbaC Cable ZAC sous le Beer
C2
F-27730 BUEIL
B1
Tel : +33 (0)2 32 62 00 92
B2
Fax : +33 (0)2 76 01 31 80
5
www.elbac.fr /
[email protected]
Construction A Group Inner conductor Bare Copper Material Diameter 7 ×Ø 0.19mm 0.22 mm² Section Insulation Solid PE Material Natural Color Diameter Ø3.7±0.10mm Outer conductor 1st Layer Drain Material Diameter
B
C 1
Bare Copper
Bare Copper
7 ×Ø 0.25mm
21 ×Ø 0.21mm
0.34 mm²
0.75 mm² 2
HDPE
PVC - Fire ret.
Green/Yellow
Blue/Red
Ø1.20±0.10mm Ø2.0±0.15mm
Electrical characteristics KX6 Impedance Capacitance Max DC resistance Inner conductor Outer conductor Propagation velocity ratio Rated voltage Insulation resitance 20°C Longitudinal attenuation
3
F requency MHz 10
Tinned Copper 7 ×Ø 0.25 mm
st
4
1 Layer Copper Clad Alum. Alu/PET Tape Material ≥ 115% Coverage 85% 16×(7×Ø0.12mm) Braiding 38 mm ± 10% Lay Length Filler Chalk Material Assembly KX 2P 2C Type Flat cable triple shotgun Position Left Middle Right 1 coax 1 pair 2 conductors Quantity 5 Sheath PVC - Fire retardant Material Black Color Ø6.1±0.15 mm Ø4.0±0.15 mm Ø5.4 ±0.15 mm Diameter 226 kg/km Mass Marking on sheath Printing « KX6 - 1P0.34 - 2×0.75 - elbaC 170205 with XXX quantity – WW/YY – XXX m » in meter still
B4 B3
A4
A2
A1
A
75 ± 3 Ω 67 ± 3 pF/m 93.8 Ω/km 22.6 Ω/km 84% 30 V >500MΩ/km
Max attenuation dB/100m 3.7
200
17.0
400
25.0
800
35.5
Return loss Frequency MHz [ 30 – 1000 ]
Return loss dB > 20
Screening attenuation Frequency MHz
Screen attenuation dB
[ 30 – 2000 ]
>75
Electrical characteristics Impedance Max DC resistance Mutual pair capacitance Rated voltage U0/U Insulation resitance 20°C
B
C
100 Ω < 54 Ω/km
< 24 Ω/km
125pF/m 300 / 300 V
450 / 750V
> 100MΩ.km
> 200MΩ.km
available per reel
WW/YY : Week/Year
Color Step
White / Pigment ink jet 1m
Meet Standards RoHS European directive
Thermal characteristics Rated Temperature
80°C
Packaging -W5 : 500m / Wooden drum
Notes
© copyright 2007 – elbaC Cable ® is a registered trademark
170205-00.pdf 26/12/2008 09:17:50