NEW
Safety Interlock Switches GS Series
Machine Safety Made Simple Achieve the Top Safety Standards
PLe
Category4
SIL3
Type4
GS Series
Locking Type
Innovative Safety Options for Any Situation
NonContact Type
2
Safety Interlock Switches GS Series INTUITIVE DESIGN Compact Size Robust Construction Highly Visible Indicators
VERSATILE MOUNTING Flexible & Direct Installation Reliable & Consistent Alignment Dedicated Brackets
SEAMLESS SYSTEM INTEGRATION Built-in Cascading Additional I/O for Monitoring Simplified System Wiring
3
INTUITIVE DESIGN NonContact Type
Locking Type
Two Unique Styles Locking Type
4
Non-Contact Type
Prevent unintended
Confirm all access points
access to hazardous
are closed during
areas, and costly machine
machine operation and
stoppage, by locking
trigger appropriate
these units during
machine stoppage if any
machine operation.
of them are opened.
Compact Size Both models feature small physical footprints to ensure they are able to
Locking Type
30 mm 1.18"
be integrated into any machine.
Non-Contact Type
The unobtrusive designs help to increase mounting versatility and
30 mm 1.18"
also prevent tampering or potential damage.
48
mm
1.89"
125 mm 4.92"
30 mm 1.18"
12.5 mm 0.49"
Robust Construction The locking type ensures operators cannot forcibly enter hazardous
Locking Type
Non-Contact Type
areas by maintaining an impressive 2000N holding force when locked.
Conventional
GS Series
The non-contact type features a durable metal housing that ensures lasting operation even when exposed to direct impacts.
Highly Visible Indicators Easily recognize the open/close status of all access points with just a
Locking Type
Non-Contact Type
quick glance. With their large size, high brightness, and angular cut, the GS Series built-in indicators can be seen from a distance and from multiple directions for instant status identification.
Closed (Green)
Ajar (Orange)
Open (Red)
Closed (Green)
Open (Red)
Error (Red blink)
5
VERSATILE MOUNTING NonContact Type
Locking Type
Direct & Flexible Installation Mounting has never been easier. Both the locking type and the non-contact type can be directly mounted to a machine frame with their built-in mounting holes. Along with this, both types can be rotated to accommodate any door style.
6
Non-Contact Type
Locking Type Facing left
Standard (front)
Facing right
Articulated Actuator The GS Series locking type models provide a level of flexibility that is
Locking Type Only
Bolt structure
unmatched by other locking type interlocks on the market. Not only do they feature a fully articulated locking bolt, but they also offer beveled entry points to ensure mating even as a door sags.
Entry structure
Stable & Reliable Detection
Non-Contact Type Only
The GS Series non-contact type models help prevent nuisance trips and machine stoppage due to
ON: 10 mm 0.39"
OFF: 18 mm 0.71"
improper closure, vibration, door sag, 0 mm 0"
0 mm 0"
and more. This is because these models offer a forgiving ON-OFF range of up to 18 mm (0.7”), ensuring reliable detection and safe machine operation.
Variety of Dedicated Brackets It is no longer necessary to fabricate costly brackets for your safety
Locking Type
Non-Contact Type
interlocks. From robust designs to slim profiles, the GS Series provides a range of dedicated brackets that will fit a variety of machine setups.
7
SEAMLESS SYSTEM INTEGRATION Locking Type
NonContact Type
Simplified Wiring Through Cascading Wiring has never been simpler or easier than with the GS Series and its
Locking Type
Non-Contact Type
built-in cascading function. Connect together safety interlocks throughout the machine and cut the total
OSSD1/2 (Safety Outputs)
number of safety outputs down to a single pair of OSSDs.
Cascade: Up to 25 units
8
OSSD1/2 (Safety Outputs)
Cascade: Up to 30 units
Additional I/O for Monitoring Even when several units are cascaded together, it is possible to quickly identify which access point is open using an additional auxiliary output from each safety interlock. These outputs can be tied to a PLC, HMI, light, etc. to easily identify the open access point.
No Additional Relay Necessary The GS Series enables all-in-one safety wiring by utilizing two OSSD
Direct connection
safety outputs along with EDM and manual reset built into specific models. This eliminates the need for a dedicated safety interlock relay or control box, as these GS models can be wired directly to a safety circuit. GS Series (OSSD equipped)
Dedicated controller
External device (e.g. contactor)
E-Stop Compatible Reduce wiring even further by integrating E-Stops into your safety interlock system. Specific GS models offer safety inputs that can be used to place E-Stops directly in series with the safety interlocks. This helps to further reduce wiring while maintaining safety.
9
ADDITIONAL FEATURES Dedicated Handle The GS-Series offers a dedicated handle for the locking type safety
Locking Type Only
LOCKED
OPEN
interlocks. This sturdy two-action handle is great for new builds or machine redesigns, and provides a complete solution for access point entry and locking.
The rugged design prevent tampering
Escape Release
Simply squeeze and slide to open
Locking Type Only
In the event that an operator finds themselves stuck inside of a hazardous area, the escape release can be used to effortlessly open a locked access point and disable power to the hazardous machinery. * M12 Connector type only
Highly visible and intuitive design
Clear markings indicate current situation
Flexible Unit Coding The GS Series offers two levels of actuator coding. On LOW, the unit will
Locking Type
Non-Contact Type
recognize any GS actuator that it encounters. On HIGH, the unit can be set to only recognize one specific actuator to prevent tampering or confusion.
10
NG
OK
NG
NG
OK
NG
Superior Environmental Resistance Locking Type
Achieve PLe Level of Safety
Non-Contact Type
ISO13849-1
All models meet IP65/67/69K and NEMA 3, 4X, 12, &
Each GS Series unit conforms to the highest level of
13 ratings for superior environmental resistance.
safety standards to ensure proper machine safety.
Simplified Connections
Locking Type Only
Non-Contact Type Only
1
2000N Holding Force
2
3
4
3
Metal head Lock bolt Locking pin
Make cascading even easier with the use of
The 2000N holding force of the locking type ensures
Y-shaped connectors and standard M12 cables.
workers cannot force their way into locked areas.
Lock-Out / Tag-Out Ready Locking Type Only
Auxiliary (Manual) Release Locking Type Only
The metal head is designed to enable easy lock-out/
All locking type units feature a manual release to allow
tag-out to maintain safety during maintenance periods.
access and shut down the machine when necessary.
11
Selecting a Safety Interlock Switch STEP
1
Select the appropriate style
1
2
3
A lock is necessary (Locking Type) Power-to-Release
Power-to-Lock
Key Features
Key Features
Signals required to release locking mechanism
Signals required to engage locking mechanism
Remains locked if unit power is lost
Lock is disengaged if unit power is lost
Ideal for high inertia machines that can remain hazardous after power is lost or removed.
Ideal for machines that stop being hazardous once power is lost or removed.
Properly guard
Guard machines
machines with
that stop
long stop times.
immediately upon loss of power.
A lock is not necessary (Non-Contact Type) Non-Contact Type Key Features Easily identify door open status Contamination resistant design Ideal for doors or gates that will remain closed without a locking mechanism Also useful for confirming origin position of moving machinery
12
Door Switch :
Origin Sensor:
Monitor door status without concern for build-up or damage.
Ensure moving components are located in the correct home positions.
4
STEP
2
Select the appropriate model
Choose the type according to the necessary functions
1
Locking type
Locking type
(Power-to-release type)
(Power-to-lock type)
GS-50 Series
GS-70 Series
Power-to-release
Power-to-lock
2
3
4
Non-contact type
GS-10 Series
Non-contact type
Standard type
High performance type
Standard type
High performance type
Simple function type
Standard type
High performance type
OSSDs
Redundant safety outputs
Switching OSSDs
(Locking Type) OSSDs can be linked to Open/Close status
—
—
—
—
—
—
AUX output(s)
Additional output(s) to monitor status
1
2
1
2
1
1
1
*1
Cascade
Connect multiple units in series
—
Y-shaped connector
Easy to use connector for cascading
—
—
—
—
—
*2
—
Interlock
Enable manual reset through unit
—
—
—
—
EDM
Monitor external devices for faults
—
—
—
—
Switching encoding level Control actuator pairing
Lock control input(s) Number of locking signals required
1
2
1
1
—
—
—
Manual release
—
—
—
*2
*2
—
—
—
—
—
—
Disengage lock through face of unit
Escape release compatible*3 Disengage lock from inside hazardous area Handle compatible*4
Integrate with two-action handle
Select a unit based on cable and output preferences
Power-to-release
Power-to-lock
Non-contact type
Standard type
High performance type
Standard type
High performance type
Simple function type
PNP
GS-51P5
—
GS-71P5
—
—
GS-11P5 GS-13P5
NPN
GS-51N5
—
GS-71N5
—
—
GS-11N5
—
PNP
GS-51P10
—
GS-71P10
—
—
GS-11P10
—
NPN
GS-51N10
—
GS-71N10
—
—
GS-11N10
—
Standard cable ( 5 m 16.40')
Standard cable (10 m 32.81')
PNP M12 connector type NPN
GS-51PC GS-53PC —
—
GS-71PC GS-73PC —
—
Standard type
High performance type
GS-10PC GS-11PC GS-13PC —
—
—
*1 If you choose interlocked mode for OSSD operation, number of AUX outputs is one. *2 Compatible with M12 connector type only *3 Compatible with KEYENCE optional escape release (GS-H02) *4 Compatible with KEYENCE optional handle (GS-H01)
13
STEP
3
Select the appropriate brackets
1
2
3
Sliding door Locking type
Non-contact type
For main unit
No bracket
For main unit Flat mounting bracket
GS-B11 For actuator Mounting bracket for sliding door (right side slides)
GS-B33*
For actuator Flat mounting bracket
GS-B11
*Mounting bracket for sliding door (left side slides) GS-B43 is also available.
Hinged door (attachment on the inside) Locking type
Non-contact type
For main unit & actuator
Mounting bracket
For main unit L-shaped mounting bracket
GS-B01
For actuator
(attachment on the inside)
No bracket
GS-B21
Hinged door (attachment on the front side) Locking type
Non-contact type
For main unit
No bracket
For main unit Flat mounting bracket
GS-B11 For actuator Hinged door mounting bracket (right-open)
GS-B31*
*Hinged door mounting bracket (left-open) GS-B41 is also available.
14
For actuator Flat mounting bracket
GS-B11
4
STEP
4
Select additional components
1
2
3
4
Cables for M12 connector type models
Standard
Type
Length
Model
Weight
Simple function type (5-pin)
5 m 16.40'
GS-P5C5
Approx. 200 g
10 m 32.81'
GS-P5C10
Approx. 390 g
5 m 16.40'
GS-P8C5
Approx. 230 g
10 m 32.81'
GS-P8C10
Approx. 420 g
5 m 16.40'
GS-P12C5
Approx. 250 g
10 m 32.81'
GS-P12C10
Approx. 480 g
20 m 65.62'
GS-P12C20
Approx. 950 g
5 m 16.40'
GS-P5CC5
Approx. 220 g
10 m 32.81'
GS-P5CC10
Approx. 400 g
1 m 3.28'
GS-P8CC1
Approx. 70 g
5 m 16.40'
GS-P8CC5
Approx. 240 g
10 m 32.81'
GS-P8CC10
Approx. 450 g
Standard type (8-pin)
High performance type (12-pin)
For extension
Simple function type (5-pin)
Standard type (8-pin)
Locking type accessories Replacement Actuator
GS-A21
Dedicated Handle GS-H01
Escape Release GS-H02
Approx. 60 g
Approx. 1070 g
Approx. 90 g
Non-contact type accessories Replacement Actuator
Y-Shaped Connector
End Terminal for Y-Shaped Connector
GS-A01
GS-Y01
GS-Y02
Approx. 15 g
Approx. 50 g
Approx. 15 g
15
Specifications
Locking Type
GS-51P5
Model Lock type
GS-51N5 GS-51P10 GS-51N10 GS-51PC GS-53PC GS-71P5 Power-to-release type
Type PNP
NPN
PNP
Lock→Unlock Unlock→Lock Locking force (Fzh) Alignment tolerance of lock Mechanical life-span Acceptable operation frequency*4 Door radius Auxiliary release
NPN
PNP
Output Max. load current Residual voltage (during ON) OFF state voltage Leakage current Max. capacitive load Load wiring resistance Output AUX Number of outputs (Non-safety Max. load current related Residual voltage output) (during ON) Control output (OSSD output)
1
Approx.1.5 mA × 2 Approx. 10 mA × 1
—
Lock control input
Approx. 2.5 mA × 1
Approx. 2.5 mA × 2
OSSD operation switching input
Power voltage Power consumption Protection circuit
PNP
PNP
1
2*5
—
Approx. 10 mA × 1
Approx. 2.5 mA × 1 Approx. 2.5 mA × 2 *6
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) 3.4 W *7 Reverse current protection, short-circuit protection and surge protection for each output IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), Enclosure Type 3/4X/12/13 (NEMA250) -20°C to +55C° -4°F to 131°F (No freezing) -25°C to +70°C -13°F to 158°F (No freezing) *8 5% to 95%RH 5% to 95%RH 10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) 30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)
Enclosure rating Operating ambient temperature Environmental Storage temperature resistance Operating relative humidity Storage relative humidity Vibration resistance Shock resistance
EN 61508, IEC 61508(SIL2/SIL3) EN 62061, IEC62061(SIL CL2/SIL CL3) EN ISO13849-1: 2015(PLd, Category 2/PLe, Category 4) EN ISO14119(Type4) IEC 60947-5-3, EN 60947-5-3 UL 61010-1, CAN/CSA-C22.2 No.61010-1
Applicable Standards (Safety)
Actuator
NPN
—
Power supply
Weight
PNP
Max 2.5 V (with a cable length of 5 m 16.40')
Reset/EDM input
Material
NPN
320 ms
Safety input
Main unit
PNP
220 ms*3 Min. 2,000 N ±2 mm ±0.08" 1 million cycles or more (with door operation speed of 1 m/s) 1 Hz Min. 250 mm 9.84" Front, back Max. 25 units Transistor outputs × 2 PNP: Max. 150 mA, NPN: Max. 100 mA Max 2.5 V (with a cable length of 5 m 16.40') Max 2.0 V (with a cable length of 5 m 16.40') Max. 0.5 mA 2.2 µF Max. 2.5 Ω Transistor output 2 50 mA
Cascading
External input (Shortcircuit current)
PNP
Advanced function type
Standard type
220 ms
Response Lock time (ms)*1*2
Lock
Advanced function type
Standard type
Output type
GS-71N5 GS-71P10 GS-71N10 GS-71PC GS-73PC Power-to-lock type
Case Lock Cable Case Lock Approx. 560 g
Approx. 770 g
SUS304, PPS, PBT, PAR, PA66, NBR Aluminum alloy, Zinc die cast (Nickel chrome plating) PVC PPS, PBT, NBR Aluminum alloy, SUS303 Approx. 380 g Approx. 560 g
Approx. 770 g
Approx. 380 g
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). *2 If the OSSD operation is open/close link mode, Detect → Not detect: 20 ms + 2 ms × (number of units cascaded -1), Not detect → Detect: 30 ms + 25 ms × (number of units cascaded -1) *3 430 ms when locked at the same time the actuator is detected. *4 Acceptable door operation frequency is 3 Hz if the OSSD operation is open/close link mode. In that case, operation distance is Sao(OFF → ON) = 3 mm 0.12", Sar(OFF → ON) = 10.5 mm 0.41". *5 The number of AUX outputs is 1 when the OSSD operation is open/close link mode. *6 The number of OSSD operation switching inputs is 1 when the OSSD operation is lock link mode. *7 Power consumption temporarily increases (Max. 10.5 W, Approx. 0.2 s) when the lock control input(s) is(are) turned ON. After that, current consumption will be within the specification. *8 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.
Mounting brackets Model Type Weight
16
GS-B21
GS-B31
GS-B41
GS-B33
GS-B43
Mounting bracket (attachment on the inside) Approx. 590 g
Hinged door mounting bracket (right-open) Approx. 380 g
Hinged door mounting bracket (left-open) Approx. 380 g
Mounting bracket for sliding door (right side slides) Approx. 260 g
Mounting bracket for sliding door (left side slides) Approx. 260 g
Non-Contact Type
GS-10PC Simple function type PNP
Model Type Output type Operating distance
Front Side
GS-11P5
GS-11N5
PNP
NPN
NPN
PNP
GS-13P5 GS-13PC Advanced function type PNP PNP
Max. 4 units*2
—
10 mm 0.39" 18 mm 0.71" 6 mm 0.24" 14 mm 0.55" 20 ms + 2 ms × (number of units cascaded -1)
Not detect →Detect
30 ms + 25 ms × (number of units cascaded -1)
Door operation
Acceptable operation frequency
Standard Using Y-shaped connector Output Max. load current Control Residual voltage (during ON) output OFF state voltage (OSSD Leakage current output) Max. capacitive load Load wiring resistance Output AUX Number of outputs (Non-safety Max. load current related output) Residual voltage (during ON) Safety input External input (Short-circuit Reset/EDM input current)
Cascading
3 Hz —
Max. 30 units — Transistor outputs × 2 PNP: Max. 150 mA, NPN: Max. 100 mA Max 2.5 V (with a cable length of 5 m 16.40') Max 2.0 V (with a cable length of 5 m 16.40') Max. 500 μA 2.2 µF Max.2.5Ω Transistor output 1 50 mA Max 2.5 V (with a cable length of 5 m 16.40') Approx. 1.5 mA × 2
—
—
Power voltage Power consumption Protection circuit Enclosure rating Operating ambient temperature Storage temperature Environment Operating relative humidity al resistance Storage relative humidity Vibration resistance Shock resistance
Approx. 5.0 mA × 1
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) 0.8 W Reverse current protection, short-circuit protection and surge protection for each output IP65/67(IEC60529), IP69K(ISO20653) (TÜV SÜD certified) Enclosure Type 3/4X/12/13 (NEMA250) -20°C to +55°C -4°F to 131°F (No freezing) -25°C to +70°C -13°F to 158°F (No freezing) *3 5% to 95%RH 5% to 95%RH 10 to 55 Hz, Double amplitude 3.0 mm 0.12", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) 30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3)
Power supply
EN 61508, IEC 61508 (SIL3) EN 6206, IEC62061 (SIL CL3) EN ISO13849-1: 2015 (PLe, Category 4) EN ISO14119 (Type4) IEC 60947-5-3, EN 60947-5-3 UL 61010-1, CAN/CSA-C22.2 No.61010-1
Applicable Standards (Safety)
Weight
GS-11PC
Detect →Not detect
Detection
Sensor main unit Actuator
GS-11N10
PNP
Sao(OFF→ON) Sar(ON→OFF) Sao(OFF→ON) Sar(ON→OFF)
Response time (ms)*1
Material
GS-11P10 Standard type
Case Cable Case Approx. 80 g
Approx. 270 g
Zinc die cast (Nickel chrome plating), PBT, PAR PVC SUS430, SUS304, PBT Approx. 480 g Approx. 80 g
Approx. 280 g
Approx. 80 g
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). *2 When AUX outputs of each unit are not used, it is possible to cascade up to 10 units. *3 When stored for a long period of time, please store it at a temperature of 55°C 131°F or lower.
Mounting brackets Model Type Weight
GS-B01 L-shaped mounting bracket Approx. 80 g
GS-B11 Flat mounting bracket Approx. 60 g
17
18
Safety PLC
General-purpose PLC
Safety PLC
Lock control device
General-purpose PLC
Lock control device
Safety PLC
General-purpose PLC
6: Red/white (safety input 2)
2: Red/black (safety input 1)
12: Light blue/black (OSSD operation switching input 1)
10: Light blue (lock control input 1)
Safety PLC
9: Gray/black (AUX output 2)
5: Gray (AUX output 1)
3: Blue (0 V)
1: Brown (+24 V)
Lock control device
8: Pink (interlock/EDM selection input)
Single Unit Example GS-73PC PNP output Advanced function type Power-to-lock type Interlock: Automatic EDM: Not used Cascade connection: No OSSD operation: Open/close link
11: Yellow (reset/EDM input)
4: Red/white (safety input 2)
8: Red/black (safety input 1)
3: Light blue (lock control input 1)
1: Gray (AUX output 1)
7: Blue (0 V)
2: Brown (+24 V)
6: White (OSSD2)
5: Black (OSSD1)
Cascade Example: 2nd Unit GS-53PC PNP output Advanced function type Power-to-release type Interlock : Automatic EDM: Not used Cascade connection: No
7: White (OSSD2)
6: Red/white (safety input 2)
2: Red/black (safety input 1)
12: Light blue/black (lock control input 2)
Safety PLC General-purpose PLC
4: Black (OSSD1)
General-purpose PLC
6: Red/white (safety input 2)
2: Red/black (safety input 1)
10: Light blue (lock control input 1)
9: Gray/black (AUX output 2)
5: Gray (AUX output 1)
3: Blue (0 V)
1: Brown (+24 V)
8: Pink (interlock/EDM selection input)
11: Yellow (reset/EDM input)
Reset switch (NO) External device (force guided relay, magnetic connector, etc.)
12: Light blue/black (OSSD operation switching input 1)
10: Light blue (lock control input 1)
9: Gray/black (AUX output 2)
5: Gray (OSSD operation switching input 2)
3: Blue (0 V)
1: Brown (+24 V)
8: Pink (interlock/EDM selection input)
11: Yellow (reset/EDM input)
7: White (OSSD2)
4: Black (OSSD1)
Cascade Example: 1st Unit GS-53PC PNP output Advanced function type Power-to-release type Interlock : Manual EDM: Used Cascade connection : Yes
7: White (OSSD2)
Single Unit Example GS-71P5 PNP output Standard type Power-to-lock type Cascade connection: No 6: Red/white (safety input 2)
2: Red/black (safety input 1)
12: Light blue/black (lock control input 2)
10: Light blue(lock control input 1)
9: Gray / black (AUX output 2)
5: Gray (AUX output 1)
3: Blue (0 V)
S1-1 K1, K2
4: Black (OSSD1)
4: Red/white (safety input 2)
8: Red/black (safety input 1)
3: Light blue (lock control input 1)
1: Gray (AUX output 1)
1: Brown (+24 V)
8: Pink (interlock/EDM selection input)
11:Yellow (reset/EDM input)
7: White (OSSD2)
4: Black (OSSD1)
Explanatory notes
7: Blue (0 V)
K2
2: Brown (+24 V)
K1
6: White (OSSD2)
5: Black (OSSD1)
Examples of wiring
Control systems related to safety. Used for monitoring, not for controlling systems related to safety.
Locking type (Power-to-release) GS-50 Series Examples
Single Unit Example GS-51P5 PNP output Standard type Power-to-release type Cascade connection: No
K2 K1
S1-1
Lock control device
General-purpose PLC
Locking type (Power-to-lock) GS-70 Series Examples
Single Unit Example GS-73PC PNP output Advanced function type Power-to-lock type Interlock: Automatic EDM: Not used Cascade connection: No OSSD operation: Lock link
Lock control device
Non-contact type GS-10 Series Examples
5: Gray (AUX output 1)
3: Blue (0 V)
1: Brown (+24 V)
2: White (OSSD2)
4: Black (OSSD1)
4: Red/white (safety input 2)
8: Red/black (safety input 1)
1: Gray (AUX output 1)
Single Unit Example GS-10PC PNP output Simple function type
7: Blue (0 V)
2: Brown (+24 V)
6: White (OSSD2)
6: Red/white (safety input 2)
2: Red/black (safety input 1)
5: Gray (AUX output 1)
3: Blue (0 V)
1: Brown (+24 V)
8: Pink (interlock/EDM selection input)
11: Yellow (reset/EDM input)
7: White (OSSD2)
4: Black (OSSD1)
6: Red/white (safety input 2)
5: Black (OSSD1)
Single Unit Example GS-11N5 NPN output Standard type Interlock : Automatic EDM : Not used Cascade connection : No
Cascade Example: 2nd Unit GS-13PC PNP output Advanced function type Interlock : Automatic EDM : Not used Cascade connection : No
2: Red/black (safety input 1)
5: Gray (AUX output 1)
3: Blue (0 V)
1: Brown (+24 V)
8: Pink (interlock/EDM selection input)
11: Yellow (reset/EDM input)
7: White (OSSD2)
4: Black (OSSD1)
Cascade Example: 1st Unit GS-13PC PNP output Advanced function type Interlock : Manual EDM : Used Cascade connection : Yes
K2 K1 K1
K2 S1-1
General-purpose PLC
Tip
Safety PLC
General-purpose PLC
Make wiring easier by using the Y-shaped connectors for double door setups.
For a double door system, generally the
Terminal block, etc.
Configuration
system stops when one of the doors opens. By using the Y-shaped connectors, this process can be made very easy using simple M12 cables. This also provide the additional AUX outputs to identify which door is open (for up to 4 doors).
Tip
Safety PLC
General-purpose PLC
5: Black (OSSD1) 6: White (OSSD2)
Non-contact type, standard type M12 connector type
GS-11PC
×2
2: Brown (+24 V)
Y-shape connector End connector
GS-Y01 GS-Y02
×2 ×1
7: Blue (0 V)
M12 connector cable Standard 5 m 16.40'
GS-P8C5
×1
3: Light blue (AUX2)
M12 connector cable for extension 1 m 3.28'
GS-P8CC1 ×1
1: Gray (AUX1) 8: Red/black (AUX3) 4: Red/white (AUX4)
Two-action handle ensures a high level of safety.
Unlike ordinary handles, the GS-H01 is
[ 1] Lock is not engaged by just closing the door
[ 2] Lock is engaged after handle is squeezed and slid
a two-action handle. Even if the door is unintentionally or accidentally closed, the machine will not automatically start. This is because it is necessary to squeeze and slide the handle into place once the door is closed to restart machine operation.
Multiple safety padlocks can be attached
Squeeze! Mount on 40 to 60 mm 1.57" to 2.36" aluminum profiles
19
Dimensions
ø0 .4 ) ø6 at s: 2 (Se knes c thi 6.8 0.27"
125 4.92"
Standard type (M12 8 pin male)
ø15.5 ø0.61"
3 4
1 10 9 4 11 12 8 7 5 6
2 8
5
M12
Advanced function type (M12 12 pin male)
6
3
1 7
Sensor + Actuator (Installed facing front) (47.5 1.87") (Lockable range 46 to 48.5) 1.81" to 1.91"
125 4.92"
103 4.06"
ø5.2 " ø0.20
54.7 2.15"
54.7 2.15"
33.8 1.33"
50 1.97"
" ø0.20 2-ø5.2
16 0.63"
29.8 1.17" 15.8 0.62"
16 0.63"
29.8 1.17"
6.8 0.27"
ø5.6 " ø0.22
6.6 0.26" ø5.2 ø0.20"
29.8 1.17" 15.8 0.62"
"
ø0.20
125 4.92"
2-ø5.2
6.6 0.26" ø5.2 ø0.20"
20
16 0.63"
50 1.97"
33.8 1.33"
ø5 . ø0 2 .20 "
54.7 2.15"
16 0.63"
103 4.06"
(47.5 1.87") (Lockable range 46 to 48.5) 1.81" to 1.91"
ø6 ø0 .4 .25 "
54.7 2.15"
Sensor + Actuator (Installed facing right)
6.8 0.27"
7.4 0.29
M12 Connector type GS-51PC/53PC/71PC/73PC
ø5.2 ø0.20" 8 cores × blue/brown: 0.22 mm2 Black, gray, red/white, red/black, white, light blue: 0.14 mm2
29.8 1.17"
ø5.2 ø0.20"
6.2 0.24"
15.8 0.62"
" .25 ø0 .4 ø6 at s: e s S e ( ckn thi .08") Out Attach 0 er d a 2 b iam le wa eter s 10 0 her: .39"
0.26" 6.6
16 0.63"
ø10 ø0.39
Hex Acrossflats S=3
17.8 0.70" 33.8 1.33"
0.20", 5.2 ø 2 x ø rbore te Coun r: ete diam ", 9 10 0.3 6.2 0.24" : p De th
54.7 2.15"
16 0.63" 54.7 2.15"
0.22" ø5.6 ø (Seat s: es k thic n ") 2 0.08
42.9 1.69"
Without the cover
A
Hex Acrossflats S=3
6.4 0.25"
29.8 1.17"
49 1.93"
" .25
A
" ø0.22 ø5.2 kness: ic (Seat th ") 8 2 0.0
103 4.06"
103 4.06"
16 0.63"
29.8 1.17"
ø12.5 ø0.49"
Cross-sectional view A-A
Upper, lower, left, and right range of bolt motion: 2 0.08" 50 1.97"
ø10.4 ø0.41"
29.8 1.17"
Actuator
Maximum screw head height during slide attaching: 6.2 0.24"
Sensor
ø9 ø0.35"
GS-50/70 Series
2
Unit: mm inch
Sensor + Actuator + Bracket (Installed facing front, installed outside of door)
52 2.05"
4.5 0.18"
GS-50/70 Series + GS-B31
Accessories: M5 hexagon socket head cap screw for attaching the actuator × 2 48.8 1.92"
29.8 1.17"
86.3 3.40"
(24.4 0.96")
58.8 2.31" 9 0.35"
16 0.63" 125 4.92"
103 4.06"
54.7 2.15"
59.8 2.35"
33 1.30" 7.6 0.30"
6.2 0.24"
2-M5
54.3 2.14"
6.2 0.24"
17.8 0.70"
ø5 ø0 .2 .20 "
43.3 1.70"
134.5 5.30"
64.2 2.53"
15.8 0.62"
ø5 . ø0 6 .22 "
6.8 0.27"
6.6 0.26" ø5.2 ø0.20"
52 2.05"
Sensor + Actuator + Bracket (Installed facing front, installed outside of door)
4.5 0.18"
GS-50/70 Series + GS-B41
Accessories: M5 hexagon socket head cap screw for attaching the actuator × 2
48.8 1.92"
29.8 1.17"
86.3 3.40" (24.4 0.96")
58.8 2.31" 9 0.35"
.2 ø5 54.7 2.15"
ø0 ø5. .2 6 2"
103 4.06"
125 4.92"
134.5 5.30"
6.2 0.24"
2-M5
64.2 2.53"
43.3 1.70"
17.8 0.70"
6.2 0.24"
33 1.30" 7.6 0.30"
59.8 2.35"
54.3 2.14"
16 0.63"
ø0
.2
0"
15.8 0.62"
6.8 0.27"
6.6 0.26" ø5.2 ø0.20"
21
Dimensions
GS-50/70 Series + GS-B33 Sensor + Actuator + Bracket (Installed facing left, installed outside of door) Accessories: M5 hexagon socket head cap screw for attaching the actuator × 2
65.8 2.59" 48.4 1.91"
57 2.24" 37.3 1.47"
30.8 1.21"
8.5 0.33"
15.8 0.62"
29.8 1.17"
84.7 3.33"
16 0.63"
46 1.81"
2-M5
103 4.06"
155 6.10"
ø5.2 " ø0.20
125 4.92"
0.39"
ø10 ø
63.8 2.51"
33.8 1.33"
22 0.87"
49.2 1.94"
4.5 0.18"
110 4.33"
74 2.91"
6.5 0.26"
37.5 1.48"
7.5 0.30"
93 3.66"
10 0.39"
18 0.71"
54.5 2.15"
Same shape ø6.4 " ø0.25
6.8 0.27"
6.6 0.26" ø5.2 ø0.20"
GS-50/70 Series + GS-B43 Sensor + Actuator + Bracket (Installed facing left, installed outside of door)
125 4.92"
103 4.06"
0.39"
6.5 0.26"
2-M5 Same shape
ø6.4
ø0.25
6.6 0.26" ø5.2 ø0.20"
22
6.8 0.27"
84.7 3.33"
ø10 ø
37.5 1.48"
18 0.71"
10 0.39" 7.5 0.30"
22 0.87" 33.8 1.33"
63.8 2.51"
8.5 0.33"
ø5.2 ø0.20 "
37.3 1.47" 15.8 0.62"
65.8 2.59" 57 2.24" 54.5 2.15"
155 6.10"
16 0.63"
46 1.81"
29.8 1.17"
49.2 1.94"
4.5 0.18"
110 4.33"
30.8 1.21"
74 2.91"
48.4 1.91"
93 3.66"
Accessories: M5 hexagon socket head cap screw for attaching the actuator × 2
Unit: mm inch
GS-50/70 Series + GS-B21 Sensor + Bracket, Actuator + Bracket (Installed facing front, installed inside of door)
69.5 2.74" 40.5 1.59"
•M 5 hexagon socket head cap screw for attaching the actuator × 2
4.5 0.18"
56.5 2.22"
Accessories: •M 5 hexagon socket head cap screw for attaching the sensor × 2
(69.5 2.74")
103 4.06"
135 5.31"
2-M5
6.2 0.24"
Same shape
54.7 2.15"
16 0.63"
16 0.63"
(15 0.59")
15 0.59"
103 4.06"
6.2 0.24"
7.4 0.29"
7.1 0.28"
48.8 1.92"
80 3.15" 140 5.51"
150 5.91"
64.8 2.55"
7.6 0.30"
29.8 1.17" 15.8 0.62"
Same shape
2-M5 6.8 0.27"
HEX Across-flats S=3
6.6 0.26"
13.9 0.55"
ø5.2 ø0.20"
GS-50/70 Series + GS-H01 + GS-H02
Keep open space of 10 mm 0.39" or more besides the escape release lever for easy actuation.
M5
6.4 0.25"
6.4 0.25" 25.2 0.99"
32.2 1.27" 30 83 3.27" 1.18" 38.7 120 4.72" 1.52"
0.75" 19
0.8 0.03"
36.8 1.45"
6.4 0.25"
5.2
0.20"
29.8 1.17" 5 0.20"
Hex Across-flats S=4 0.16"
R24 0.94" 6.4 0.25"
ø13.4 ø0.53"
Same shape
R21 " 0.83
70.9 2.79"
20 0.79"
(6.4 0.25")
(6.4 0.25")
36 1.41" 76 2.99"
46.4 1.83" 6 0.24"
41 1.61"
.2 ø5 .20" ø0
70.9 2.79"
6 0.24"
48 1.89" 25.3 1.00"
Seat thickness 13.5 0.53" Outer diameter ø12 ø0.47" washer attachable
Seat thickness 15 0.59"
76 2.99"
Thickness of wall 27 to 60 1.06" to 2.36"
272.9 10.74"
Same shape
ø5.2 ø0.20"
158 6.22"
M5 170.6 6.72"
(292.9 11.53")
10.7 0.42"
19 0.75"
38.7 1.52"
120 4.72"
111.5 4.39"
5 0.20" 33 1.30"
M5
ø12.5 ø0.49"
7 0.28"
104.9 4.13"
27.9 1.10"
115.9 4.56" 10.4 0.41" 20 0.79"
166.4 6.55"
133.3 5.25"
38 1.50"
29 1.14"
Through hole ø14 ø0.55
Mounting surface recommended dimensions
6.8 0.27" 5.5 0.22"
13 0.51" 42.8 1.69"
23
Dimensions
GS-50/ 70 Series + GS-H02
Keep open space of 10 mm 0.39" or more besides the escape release lever for easy actuation.
103 4.06"
38.7 ø30 1.52" ø1.18"
M5
M5
Spot-facing 4 0.16" 14.9 0.59"
M5
46.7 1.84" 6 0.24"
0.8 0.03"
ø28 ø1.10" ø13.4 ø0.53"
6.6 0.26"
30 1.18"
38.3 1.51" 3.8 0.15"
38.7 1.52"
125 4.92"
6 ø5. 2" 2 ø0.
103 4.06"
16 0.63"
29.8 1.17"
19 38.7 0.75" 1.52"
"
.20
ø0
ø12.5 ø0.49"
.2
ø5
5.2 29.8 0.20" 1.17"
R24 0.94 R2 " 10 .83 "
83 3.27"
Thickness of wall 40 to 73 1.57" to 2.87" 29.8 1.17"
54.7 2.15"
19 0.75"
Through hole ø14 ø0.55"
Mounting surface recommended dimensions
6.8 0.27"
ø5.2 ø0.20"
GS-10 Series Sensor
Actuator
15 0.59"
38 1.50" 48 1.89"
24 0.94" (detection center)
48 1.89"
5.9 0.23" (detection center)
0.20" 5
38 1.50"
2-4.2 0.17"x9.2 0.36" through hole 7.4 0.29"x12.4 0.49" depth of counterbore: 4.2 0.17" (both surfaces)
5 0.20"
3 0.12" (detection center)
" .17 ø0 ole 4.2 h h f 2-ø hroug pth o " t " de .17 .31 4.2 0 ø0 12.5 0.49" ø8 bore: er 7 0.28" ount c
11.8 0.46"
5 0.20" 30 1.18"
5.9 0.23" (detection center)
M12 Connector type GS-10PC/11PC/13PC
11.8 0.46" GS-13P5 ø5.2 ø0.20" 9 cores × blue/brown: 0.22 mm2 Black, gray, red/white, red/black, white, pink, yellow: 0.14 mm2 GS-11P5/GS-11N5/GS-11P10/GS-11N10 ø5.2 ø0.20" 8 cores × blue/brown: 0.22 mm2 Black, gray, red/white, red/black, white, light blue: 0.14 mm2
49 1.93"
Simple function type (M12 5 pin male)
Standard type (M12 8 pin male)
2 3
5 4
M12
3 1
4
2 8
5
Advanced function type (M12 12 pin male)
6
3
1 7
1
2
10 9 11 12 8
4 5
6
7
ø15.5 ø0.61"
ø14.6 ø0.57" 25.4 1.00" 38 1.50"
24
M12 male
M12 8 pin female
M12 male 24 0.94"
M12 8 pin male
54.3 2.14"
25 0.98"
2-ø4.5 ø0 ø8 ø0 .18" Mou nti .31" S pot-fa ng holes cing 4 .2 0.1 7"
M12 female
End terminal for Y-shaped connector GS-Y02
ø14.6 ø0.57"
ø14.6 ø0.57" 8.9 8.9 0.35" 0.35" M12 female
13.9 24.9 0.98" 0.55"
Y-shaped connector GS-Y01
3 4 5 19 0.75"
2 8 6
2
1 7
1 7
3 4
8 6
5
ø14.5 ø0.57"
Unit: mm inch
GS-10 Series + GS-B11 Accessories: M4 hexagon socket head cap screw × 2 Bracket + Sensor
ø5 . ø0 2 .20 "
3 0.12"
7 0.28"
74 2.91" 8.9 0.35" (detection center)
3 0.12" (detection center)
15 0.59"
8.9 0.35" (detection center)
14.8 0.58"
29.8 1.17"
30.5 1.20" (detection center)
2xHEX Across-flats S=3
Same shape
74 2.91"
6.5 0.26"
2xHEX Acros s-flats S=3
30 1.18"
Same shape
4-M4×0.7 0.03"
Bracket + Actuator
30.5 1.20" (detection center)
74 2.91"
29.8 1.17" 5 0.20" 16.5 0.65" 15 0.59" 7.5 0.30"
61 2.40" 38 1.50" 18 0.71" 22 0.87" 26 1.02" 4.5 0.18"
6.5 0.26"
Bracket
12.5 0.49" 29.8 1.17"
14.8 0.58"
GS-10 Series + GS-B01 Accessories: M4 hexagon socket head cap screw × 2 Bracket + Sensor
26 1.02" (Center of sensor installation)
12 0.47"
t=3 0.12"
3 0.12" (detection center)
35.9 1.41" (detection center)
36 1.42"
35.9 1.41" (detection center)
41.8 1.65"
36 1.42"
41.8 1.65"
12 0.31" 8 0.47"
6.5 0.26"
Standard cable
Extension cable
M12 female 8 pin/ 5 pin
M12 male 8 pin/ 5 pin
47.1 1.85"
70 2.76"
L(mm inch) 5000 196.85" 10000 393.70" 5000 196.85" 10000 393.70" 5000 196.85" 10000 393.70" 20000 787.40"
2 1
5 4
Number 1 2 3 4 5 6 7 8 9 10 11 12
49 1.93"
47.1 1.85"
7 0.28"
L
92 3.62"
L Models GS-P5C5 GS-P5C10 GS-P8C5 GS-P8C10 GS-P12C5 GS-P12C10 GS-P12C20
ø15.5 ø0.61"
ø15.5 ø0.61"
ø15.5 ø0.61"
GS-P12C5/P12C10/P12C20 ø5.2 ø0.20" 12 cores × Blue, Brown 0.22 mm2 Black, Gray, Red/White, Red/Black, White, Pink, Gray/Black, Yellow, Light blue, Light blue/Black 0.14 mm2 GS-P8C5/P8C10 ø5.2 ø0.20" 8 cores × Blue, Brown 0.22 mm2 Black, Gray, Red/White, Red/Black, White, Light blue 0.14 mm2 GS-P5C5/P5C10 ø5.2 ø0.20" 5 cores × Blue, Brown 0.22 mm2 Black, Gray, White 0.14 mm2
ø5.2 ø0.20"
17.5 0.69"
M12 female 12 pin/ 8 pin/ 5 pin
60 2.36"
60 2.36"
ø5 . ø0 2 .20 "
26 1.02"(detection center)
26 1.02" (detection center)
2xHEX Across-flats S =3
38 1.50" 48 1.89"
6.5 0.26"
26 1.02" 13 0.51"
6.5 0.26"
7 0.28"
13 10 0.51" 0.39"
2×M4
30 1.18"
32 1.26" 36 1.42"
6.5 0.26" 7.25 0.29"
Bracket + Actuator 2xHEX Across-flats S=3
38 1.50" 46 1.81" 60 2.36"
4.5 0.18" 4.5 0.18"
6 0.24" 13 0.51"
2 0.08"
Bracket
5 pin Brown White Blue Black Gray – – – – – – –
2 3
1 7
6
2
1
3 4
8 5
Color 8 pin Gray Brown Light blue Red/White Black White Blue Red/Black – – – –
10
9
3
12 11
8 7
6
4 5
12 pin Brown Red/Black Blue Black Gray Red/White White Pink Gray/Black Light blue Yellow Light blue/Black
Models GS-P5CC5 GS-P5CC10 GS-P8CC1 GS-P8CC5 GS-P8CC10
L(mm inch) 5000 196.85" 10000 393.70" 1000 39.37" 5000 196.85" 10000 393.70"
C A D D ATA D O W N L O A D
www.keyence.com/CADG
25
Related products
GL-R SERIES
Global Standard for Light Curtains
Robust Housing The GL-R Series features a recessed lens, extruded aluminum housing, and high enclosure ratings to ensure lasting operation in any environment.
STANDARD TYPE GL-RF (Detection capability: ø14 mm ø0.55")
GL-RH (Detection capability: ø25 mm ø0.98")
GL-RL
High Powered Whether detecting over a long range or in an area with high debris and build-up, the GL-R Series provides high power to maintain stable detection and eliminate nuisance trips.
Easy to Align Alignment has never been easier! The GL-R Series offers built-in indicators for easy visual alignment, as well as an optional laser alignment tool for more difficult setups.
26
(Detection capability: ø45 mm ø1.77")
SZ-V SERIES
Industry Leading Safety Scanner
Fully Customizable Setup From area monitoring to access protection to collision prevention, the SZ-V Series offers a fully customizable
Integrated
Separate
safety solution for any situation.
Safety Laser Scanner SZ-V Series
Seperate Display Easily monitor scanner operation and status without
Left Camera
Right Camera
entering the hazardous area by utilizing the SZ-V Series detachable display.
World's First Built-in Camera Quickly identify the cause of any recent trip by actually
Detection Plane
seeing what entered the protected area through either pictures or even videos.
27
NonContact Type
Locking Type
Safety Interlock Switches GS Series
CALL TOLL FREE
T O C O N TA C T Y O U R L O C A L O F F I C E
1-888-KEYENCE 1 - 8 8 8 - 5 3 9 - 3 6 2 3
www.keyence.com
SAFETY INFORMATION Please read the instruction manual carefully in order to safely operate any KEYENCE product.
CONTACT YOUR NEAREST OFFICE FOR RELEASE STATUS
KEYENCE CORPORATION OF AMERICA Head Office 500 Park Boulevard, Suite 200, Itasca, IL 60143, U.S.A. AL AR AZ CA
Birmingham Little Rock Phoenix San Francisco
CA CA CA CA
San Jose Cupertino Los Angeles Irvine
CO FL GA IA
Denver Tampa Atlanta Iowa
IL IN KY MA
Chicago Indianapolis Louisville Boston
PHONE: +1-201-930-0100 FAX: +1-855-539-0123 E-mail:
[email protected] MI MI MN MO
Detroit Grand Rapids Minneapolis Kansas City
MO NJ NY NC
St. Louis Elmwood Park Rochester Charlotte
NC OH OH OR
Raleigh Cincinnati Cleveland Portland
PA PA SC TN
Philadelphia Pittsburgh Greenville Knoxville
TN TX TX WA
Nashville Austin Dallas Seattle
WI Milwaukee
KEYENCE CANADA INC. Head Office PHONE: +1-905-366-7655 FAX: +1-905-366-1122 E-mail:
[email protected] Montreal PHONE: +1-514-694-4740 FAX: +1-514-694-3206 Windsor PHONE: +1-905-366-7655 FAX: +1-905-366-1122 The information in this publication is based on KEYENCE’s internal research/evaluation at the time of release and is subject to change without notice. Company and product names mentioned in this catalog are either trademarks or registered trademarks of their respective companies. The specifications are expressed in metric units. The English units have been converted from the original metric units. Copyright © 2019 KEYENCE CORPORATION. All rights reserved.
KA1_exceptMX-1017