C
o
n
t
ROOM
1 1 DOOR
DOOR
ROOM
2 3 DOOR
ROOM
1 1 DOOR
ROOM
1 3 DOOR
ROOM
3 5 DOOR
DOOR
Hands-free Color Video Intercom
JF-1MD
1
ROOM
2 3
ROOM
Hands-free Color Video Intercom, Picture Memory
JF-2MED
3
Hands-free Color Video Intercom, PanTilt, Picture Memory
JA-2MECD
7
Video Sentry Color Tilt
KCS-1ARD
9
KC-1GRD
11
Video Sentry Color Tilt
KB-3MRD
13
Integratable Audio / Video Security
Chime Tone Intercom
TCS-MH
25
Chime Tone Intercom
IE-1AD(U)
26
Chime Tone Intercom
IE-1GD(U)
27
Chime Tone Intercom
IE-2A2DU
28
ROOM
2 6
Chime Tone Intercom
IE-8MD
29
Audio Door Stations
30
Wide Angle Video Sentry
MK-1GD
17
PanTilt Video Sentry
MK-2MCD
18
MULTI-UNIT ENTRY SECURITY Hands-free Color Video Bus Apartment System
ROOM
1 6 DOOR
24
ROOM
2 3 DOOR
15
C-123L/A
ROOM
2 3 DOOR
Chime Tone Intercom
ROOM
1 3 DOOR
23
ROOM
1 1 DOOR
Video Sentry Color Tilt
ROOM
1 1 DOOR
DA-1AS
ROOM
1 1 DOOR
Two-Wire Electric Lock Door Phone
ROOM
1 3 DOOR
s
ROOM
1 1 DOOR
8 120 AX DOOR
t
AUDIO ENTRY SECURITY
VIDEO ENTRY SECURITY DOOR
e n
PanTilt Video Sentry
MY-CU & IE-8MD
GH SYSTEM
19
31
System outline
ROOM
3 8
31~44
Master Sentry
ENTRANCE RESIDENCE
LEF-C Video
20
33
5 48 Standard System configuration ENTRANCE RESIDENCE
Video Accessories
KC-32EU, JBW-BA, RY-3DL KAW-D, MCW-S, MK-2DA, MK-2DG, MYW-BA
21 22
16 500 Expanded System configuration Entrance station Residential station Security guard station, Control unit GH lift control adaptor GH CCTV camera interface adaptor for Reception Cabling (standard) Wiring (standard)
34 35 38 39 41 42 43 44
Bus Apartment System
45~55
GF SYSTEM ENTRANCE
RESIDENCE
Two-Wire Bus System
5 100 or 250 GF Audio ENTRANCE
45
RESIDENCE
Four-Wire Common B&W Video System
5 100 or 250 GF Audio/Video
47
ENTRANCE RESIDENCE
Two-Wire Bus System
8 4,800 GF Multi-Tower Example
2
DOOR ENTRANCE MASTER SERVICE SIDE STATION
3
ROOM RESIDENCE SUB PUBLIC SIDE
49
GF Components
51
ENTRANCE RESIDENCE
1 4
Two-Wire Electric Lock Door Phone
DA-4DS
56
ENTRANCE RESIDENCE
Audio Entry Security
1 58 VC-M SINGLE-FAMILY HOME
MULTI-TENANT
COMMERCIAL BUILDING
FACTORY
57
OFFICE
SCHOOL
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM DOOR
ROOM
1 1 MASTER
Open Voice Intercom
LEM-1DL
59
VIDEO ENTRY SECURITY
SUB
1 3
Open Voice Intercom
LEM
60
STATION
Open Voice Intercom
11 DOOR
LEF
3 8 DOOR
61
ROOM
Open Voice Intercom
LEF-C
63
ROOM
3 8
Open Voice Intercom
LEF & MYW-P1L/P3L
64
Handset Intercom
LE Sub stations & Accessories MASTER
SUB
1 3 STATION
Handset Intercom
AT-406 TD-H/B lTD-Z/A
ROOM
STATION
67 69
Handset Intercom
90
YAZ-90-3W DOOR
70
Integratable Audio / Video Security
8 120 AX MASTER
AUDIO ENTRY SECURITY
Handset Intercom
1 24 TD-H/B & MY-CU MASTER
66
Handset Intercom
25 DOOR
65
71
SUB
Commercial Security Intercom
64 1,024 AI-900 SERVICE PUBLIC
1 1 MASTER
SUB
Security Window Intercom
IMU-100
SUB
ROOM
10 1 DOOR
ROOM
10 1 STATION
SUB
85
SUB
SUB
SUB
86
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Mid-Power Intercom
MP-S
87
High-Power Intercom
88
Nurse Call
1 80 NHX MASTER
84
Master / Sub Intercom
TC-M & TB-ADM10
2 10 AP-M MASTER
83
Master / Sub Intercom
TC-M & TB-AD10
MC-60/4A
1 3 MASTER
81
Market-Com
60 MASTER
79
Master / Sub Intercom
2 100 TC-M DOOR
MULTI-UNIT ENTRY SECURITY
Master / Sub Intercom
1 120 NEM MASTER
75
89
Nurse Call
1 120 NEM
95
ACCESS CONTROL, ACCESSORIES & POWER SUPPLIES Access Control
AC-10S, AC-10F
ACCESS CONTROL, ACCESSORIES & POWER SUPPLIES
99
Accessories
IER-2, EL-10S, RY-PA, RY-AC/A TAR-3, MAW-B Power Supplies
101 102 103
COMMUNICATION DISTANCE & INDEX Communication Distance Compatibility of video intercom system Index
105 106 107
COMMUNICATION DISTANCE & INDEX
Hands-free Color Video Intercom DOOR
Features
ROOM
1
• One door & two monitors (3.5 inch); room to room communication is not available • Total hands-free communication, auto-voice actuation • Streamlined & Thin design, only 27 mm thickness • Vandal resistant video door stations are available • White LED illumination turns on in low-light conditions
1+1 JF-1MD Door station
Master station
VIDEO ENTRY SECURITY
2
IER-2
2
2
Call extension m P.101
PT
JF-DV
PS18
Vandal-resistant video door station, surface mount
JF-1MD Master station w/color monitor
or
Access Contorol m P.99 AC-10S Access control keypad, surface mount
or
AC-10F Access control keypad, flush mount
JF-DA
JF-DVF
Standard video door station
Vandal-resistant video door station flush mount
JF-DV + AC-10S
Power supply PS-1820S PS-1820UL PS-1820 m P.104
Communication network
Wiring 100m / 1.0mma JF-DV
JF-1MD
JF-1FD
JF-1MD 2
6 JF-1SD 6
JF-DV
DOOR
A1 A2
A1 A2
M
EL-10S
JF-1SD PT
CALL EXT
IER-2
S S
1 E
SUB
SUB
B1 B2
B1 B2
DOOR RELEASE
DOOR RELEASE
L L
L L
DC18V
DC18V
JF-1FD PS18 (BR) (RD)
Room-to-room communication is not available. BR: Brown RD: Red
(BR)
External device
(RD)
PRESS TALK
PRESS TALK
ON OFF
ON OFF
PS18
External device
: PS-1820/S/UL PT : AC Transformer
Cable Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed.
1
• • • • • •
Instant voice call-in with image Visual monitoring with audio for 1 minute Press-to-talk operation available Talk LED lights in red while speaking Optional audio sub station (JF-1SD) Option - Option button, press-to-talk setting
Lineup
Sub station
VIDEO ENTRY SECURITY
6
JBW-BA Long distance adaptor m P.21 *Max. 300m away from Master/sub to Door.
JF-1FD Sub station w/color monitor
or
6
JF-1SD Audio sub station
KAW-D 30k angled box m P.22
JBW-D
15k angled box
Boxed sets JFS-1AD: JF-1MD, JF-DA JFS-1ADV: JF-1MD, JF-DV JFS-1ADF: JF-1MD, JF-DVF Add appropariate power supply
EL-10S Electric door strike m P.101
Unit dimensions
Image view area JF-DA, JF-DV, JF-DVF
JF-1MD, JF-1FD
JF-1SD
★
185cm (2)
27
135
82
JF-DVF
27
★
(3)
★
50cm
★
40
150cm 50cm
JF-DV
210cm
180cm ★ ★ 65cm 70cm 65cm ★ 140cm ★ 115cm
210
179
(1)
5.5
120cm ★
JF-DA
95cm
★
★
approximate
131
209
173
(1) Initial horizontal view (2), (3) When camera is turned up or down (JF-DA only)
Specifications (JF-1MD) 99
98
25 135
29
108.5
120 88
Power source Power supply Consumption Calling Communication
JBW-BA 83.5
IER-2
45
40
122.5
61
Video monitor Scanning line Night viewing Door release Option output Wiring Wiring distance
18V DC PS-1820S, PS-1820UL, PS-1820 Max. 450mA (JF-1MD). Max. 300mA (JF-1FD) Chime. Image & audio, approx. 45 sec. Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. 3.5 inch direct-view TFT color LCD. 525 lines Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) 24V AC/DC less than 1.6A (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: 6-cond., mid cap, solid, non-shielded. Master/Sub (farthest room station) to door: 50m (0.65mma) 100m (1.0mma) Master to IER-2: 75m (0.65mma) 150m (1.0mma)
2
Hands-free Color Video Intercom Features
DOOR
ROOM
2
3 JF-2MED
• Two doors & three monitors (3.5 inch) • Total hands-free communication, auto-voice actuation • Built-in picture memory; Record visitor both automatically & manually • Voice memo; Internal short voice messages can be recorded and played back
Door station
Master station
VIDEO ENTRY SECURITY
4
2 2
2
IER-2 Call extension m P.101
PT
JF-DV
PS18
Vandal-resistant video door station, surface mount
JF-2MED Master station w/color monitor and picture memory
2
Access Contorol m P.99 AC-10S or
Vandal-resistant video door station flush mount
AC-10F
JF-D
JF-DA
JF-DVF
Access control keypad, surface mount
or
Standard video door station
Power supply PS-1820S PS-1820UL
Access control keypad, flush mount
Audio only door station
JF-DV + AC-10S
PS-1820 m P.104
Communication network
Picture memory If a call is received from the Video Door Station, the unit starts recording automatically, or you can also start recording by pressing the REC button manually.
JF-DV JF-2HD
M
JF-2SD
JF-2MED
3/16
2006 02 DEC 18 : 45 PRESS THE TALK BUTTON TO END
M
Up to 50 pictures can be recorded. A maximum length of approx. 8 seconds (8 shots) can be recorded with 1 picture and 1 shot for each second. Up to 10 pictures can be protected from automatic overwriting.
JF-2SD
Plays 8 shots continuously so that you can see them as a moving image. JF-2HD 8 shots/picture JF-DVF
Selective control of door release at communicating Door station. All-Call the inside stations by voice, then talk individually. Both the manual recording of visitors and the playback of recorded images can be controlled on Master and Sub Inside Stations.
3
• Message for entrance; Outgoing messages can be recorded and sent out at the door station manually • Streamlined & Thin design, only 32 mm thickness • Vandal resistant video door stations are available • White LED illumination turns on in low-light conditions • Visual monitoring with audio for 1 minute • External sensor connectable for notifying and pictograph on monitor • Instant voice call-in with image
• • • • • • • •
Different chimes to indicate which door is calling Press-to-talk operation available All-Call for internal communication Transfer of door station call to other inside stations Selective door release control (with RY-3DL) Optional audio sub master station (JF-2SD) Audio door station in lieu of 2nd video door station Option - Option button, Video signal (NTSC) output, External talk switch, press-to-talk restriction
Lineup
Sub station
JF-2HD
JF-2HD 4
or
2
or
RY-3DL
JBW-BA
Door release adaptor m P.21
Long distance adaptor m P.21 *Max. 300m away from Master to Door
2
JF-2SD
JF-2SD
Audio sub master station
Audio sub master station
VIDEO ENTRY SECURITY
Sub master station w/color monitor
Sub master station w/color monitor
KAW-D 30k angled box m P.22
JBW-D
15k angled box
Boxed sets JFS-2AED: JF-2MED, JF-DA JFS-2AEDV: JF-2MED, JF-DV JFS-2AEDF: JF-2MED, JF-DVF Add appropariate power supply
EL-10S Electric door strike m P.101
Voice Memo
Message for entrance
Easily record and playback a short message for someone or a reminder for yourself using the Voice Memo feature.
Outgoing messages can be recorded and sent out at the Door Station manually.
Recording
Playing Hi Dad. SENDING MESSAGE
02 DEC 18
:45
02 DEC 18 :45 02 DEC 19 :47 ( SEC.REMAINING RECORDING 7
)
PLAYING MEMO
Please come on in.
Hi Dad. Mom and I are at the store. See you soon! Up to 3 Voice Memos for internal use can be recorded (maximum of approx. 15 seconds/memo).
2 messages can be recorded (maximum of approx. 10 seconds/message).
External sensor When an external sensor is activated, the Inside Station monitor shows a warning sign and a notification sound goes off. Also, a notification sound goes off on the Door Station 1 by setting.
02 DEC 18 :45
RECORDING ( 7 SEC.REMAINING)
External Sensor
4
Hands-free Color Video Intercom Wiring
100m / 1.0mma
100m / 1.0mma
JF-DV
VIDEO ENTRY SECURITY
JF-2MED
JF-2HD
JF-2HD
2 2
4
4
2 or 2
#1
JF-2SD
JF-2SD
JF-DVF
or
2
2 IER-2
#2
PS18
#1
A1 A2
#2
DOOR1
SUB
SUB IN
SUB OUT
SUB IN
SUB OUT
A1 A2
B1 B2
B1 B2
B1 B2
B1 B2
B1 B2
DOOR2
A1 A2
A1 A2
IER-2
CALL EXT
Setting is required on JF-2MED.
1 E
S S
DC18V
DC18V
DC18V
ON OFF
ON OFF
PS18
*ON side when no 3rd unit is connect (leave in the factory setting)
EL-10S
Door release output setting is required. (24V AC/DC, 0.5A N/O dry closure contact)
Option output (24V DC, 0.5A N/O dry closure contact)
PT
Brown Red Orange Yellow
Selective door release RY-3DL EL-10S
EL-10S
PT
L1 C1 L1 L2 C2 L2
JF-2MED
L L SW SW
Option connector
V+ Vb1 b2 E PK FS KS E
Brown Red Orange Yellow Green Blue Purple Gray White
Video signal output (NTSC, 1Vp-p/75Ω)
To RY-3DL
Press-to-talk setting input If the blue and white wires are shorted, press-to-talk will not be operable.
Option connector
b1 b2 b3 L D1 E D2
Foot switch input Connect a commercially-available foot switch to the purple and white wires (N/O dry closure contact).
OG(b1) YE(b2) GR(E) Release connector
External sensor input Setting is required on JF-2MED.
BR(L) RD(L)
N/O dry closure contact
DC 18V
+ –
+ –
PS18 :PS-1820S, PS-1820UL, PS-1820 PT
Release connector
PS18
Input method
External sensor input (start signal only detection method)
Detection confirmation time 100 mS or more Contact resistance
During dry closure: Less than 700Ω
Terminal short current
Less than 10 mA
Voltage between terminals
Less than 20V DC (when open between terminals)
:AC Transformer
Cable Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed.
5
Mounting locations l Video door station Do not install a video door station in any of the following locations where lighting or the ambient environment could impact the display on the video master station due to the characteristics of the door station's camera.
Under street lights or door lights
VIDEO ENTRY SECURITY
Locations subject to direct sunlight
Other locations subject to strong lighting conditions
l Monitor station 1. Install the master monitor station and sub monitor station in places where the screens are not exposed to direct sunlight.
2. The master monitor station and sub monitor station have switches on both sides. Allow at least 5 cm of open space on either side.
3. Allow 15 cm or more of vertical open space from the center of the mounting bracket in order to mount the master monitor station and sub monitor station.
JF-2MED / JF-2HD + 15 cm + 5 cm
Unit dimensions
+ 5 cm
Image view area JF-DA, JF-DV, JF-DVF
JF-2MED, JF-2HD
JF-2SD
JF-DV
185cm
27
★
(2)
135
90
32
(3)
150cm
25
98
25
50cm
JF-D
99
120cm
108.5
29
122.5
25
42
33
132
100
AC-10F
55 68.5
125
98
Power source Power supply Consumption Calling Communication
61 74
AC-10S
★
approximate
Specifications (JF-2MED) 28.5
RY-3DL
JBW-BA 83.5
120 88
98
40
45
IER-2
★
95cm
(1) Initial horizontal view (2), (3) When camera is turned up or down (JF-DA only)
140
135
50cm
130
209
131
5.5
JF-DA
★
180cm ★ ★ 65cm 70cm 65cm ★ 140cm ★ 115cm
★
JF-DVF
★
210cm
★
173
160
179
(1)
117
5
45
Video monitor Scanning line Video output Night viewing Door release Option output Wiring Wiring distance
18V DC PS-1820S, PS-1820UL, PS-1820 Max. 400mA (JF-2MED). Max. 220mA (JF-2HD) Chime. Image & audio, approx. 45 sec. Approx. 1 min. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. 3.5 inch direct-view TFT color LCD. 525 lines NTSC, 1Vp-p/75Ω Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 500mA (N/O dry closure contact) 24V AC/DC, 1.6A (N/O dry closure contact) Door to master: 2-cond., mid cap, solid, non-shielded. Master to sub: 4-cond., mid cap, solid, non-shielded. Master to door: 50m (0.65mma) 100m (1.0mma) Master to farthest sub: 50m (0.65mma) 100m (1.0mma) Master to IER-2: 75m (0.65mma) 150m (1.0mma)
6
PanTilt Hands-free Color Video & Motion-sensor camera integration Features
DOOR
ROOM
2
3 JA Series
• Two color PanTilt Camera door stations, three inside monitor stations (4 inch LCD) • Motion-sensor camera (max.2) • Built-in picture memory (JA-2MECD only) • Surveillance mode SET through sensor-cameras. Activates monitor and internal alarming (& picture save in JA-2MECD)
Door station
Master station
VIDEO ENTRY SECURITY
Picture memory
2 2 PT
4
2 2
IER-2 2
Call extension m P.101
PS24
Standard
or
Non-Picture memory
JA-DGC PanTilt color video door station - semi-flush mount
JA-2MECD 2
PanTilt color monitor master station, picture memory
2
PT
or
JA-DAC PanTilt color video door station - surface mount
JA-D Audio only door stationsurface mount
Power supply PS-2420S PS-2420UL
JDW-C Motion-sensor camera
Motion-sensor camera
JA-2MCD PanTilt color monitor master station
PS-2420 m P.104
Communication network JA-DGC
PS24
JDW-C
Wiring
100m / 1.0mma
JA-2HCD
100m / 1.0mma
2
JA-DGC JA-DAC JDW-C
M
JDW-C
2
or
JA-2MECD JA-2MCD JDW-C
2
JA-2HCD
JA-2HCD 4
4
2
JA-2SD
JA-2SD
JA-DAC A1 A2 JA-DAC
JA-D 1 2
JDW-C
NP
NP
A1 A2 JDW-C
M
or
NP
C1 C2
A1
B1
B1
B1
B1
B1
A2
B2
B2
B2
B2
B2
Cable Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed.
NP
C1 C2
JA-2HCD
DC24V
+
+
+
A2
-
-
-
ADAPTER -1
PS24
BR PT
RD OG
PT
YE
A
A
C1 OFF
ADAPTER -2
CALL EXT
S S
C1 C2
EL-10S EL-10S
DOOR2
A1
C2
JDW-C
JA-2SD M Door release activation Hands-free voice-activated communication after TALK button is pressed.
7
DOOR1
or
JA-2MECD, JA-2MCD
JA-DAC
NP
or 2
or 2
PT
EL-10S
JA-2SD
IER-2 NP 1 E
L1 L1 L2 L2
Wiring for JA-2SD; Two wires only. + / - wires are not necessary. B1,B2: marked with SUB IN , SUB OUT PS24 :PS-2420/S/UL PT : AC transformer BR: Brown RD: Red OG: Orange YE: Yellow
ON
• • • • • • • •
• • • •
Total hands-free communication, auto-voice actuation Instant voice call-in with image Press-to-talk available White LED illuminator turns on in low-light conditions All Call for internal communication Transfer of door station call to other inside stations Optional video (JA-2HCD) or audio (JA-2SD) sub stations Audio door station in lieu of JA video door station
Talk LED lights in red while speaking Visual monitoring with audio through all cameras Two door release contacts for selective control Options: -Foot talk switch -Manual Talk switch restriction -RY-3DL for large door releases locally available -Video output to video device (NTSC)
Lineup
Sub station
JA-2HCD
PanTilt color monitor sub master station
PanTilt color monitor sub master station
4
KAW-D
AC-10S
30k angled box m P.22 15k angled box
Access control keypad, surface mount m P.99
JBW-BA
AC-10F
Long distance adaptor m P.21
Access control keypad, flush mount m P.99
JBW-D
2
or
or
2
JA-2SD
JA-2SD
Audio sub master station
Audio sub master station
VIDEO ENTRY SECURITY
JA-2HCD
EL-10S Electric door strike m P.101
Unit dimensions
Image view area JA-DAC, JA-DGC
JA-2MECD
JA-2MCD, JA-2HCD
JA-DGC 220cm
210
172
90cm
210
50cm
★
130cm
★
180cm
★
★
150cm
180cm
★
65cm 42
160
115
42
160
★
12.5 19 37
50cm ★
JA-2SD
JA-D
98
182 40
JBW-BA
29
102
93.5
Calling Communication
Video monitor Scanning line Night viewing Door release Wiring
108.5
83.5
120
122.5 88
Power source Power supply Consumption
28.5 82
IER-2
approximate
Max. pan-and-tilt view area: 90cm Vert., 180cm Horiz. (approx.)
JDW-C
210 98
44 47.5
★ 45cm 90cm
Specifications (JA-2MECD, JA-2MCD, JA-2HCD, JA-2SD)
130
130
JA-DAC
★
61
Wiring distance
24V DC PS-2420S, PS-2420UL, PS-2420 Max. 750mA(JA-2MECD).Max. 680mA(JA-2MCD). Max. 290mA(JA-2HCD). Max. 120mA(JA-2SD) Chime. Image & audio, approx. 30 sec. AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 2 sec. or until talk LED turns on. 4 inch direct-view TFT color LCD. 525 lines White LED projected up to 30cm from camera. 24V AC/DC, 500mA (dry closure contact L, L) Parallel, station to station(non-twisted, non- shielded). Vinyl-jacket, PE insulation. Master station ~ Door 50m(0.65mma) 100m(1.0mma) Master station ~ Motion sensor camera 50m(0.65mma) 100m(1.0mma) Master station ~ farthest sub 50m(0.65mma) 100m(1.0mma) Master station ~ IER-2 50m(0.65mma) 100m(1.0mma)
8
Video Sentry Color Tilt DOOR
ROOM
1
1 KCS-1ARD Door station
Features • Clear and bright image with color TFT LCD monitor and DSP video door station • TILT camera control • INSTANT ON audio & image of entry when called
Master station
VIDEO ENTRY SECURITY
2 2
2 PT
KC-DAR
PS24
Video door station
KC-1MRD Master station
Power supply PS-2420S PS-2420UL
Communication network
PS-2420 m P.104
Wiring 100m / 1.0mma
100m / 1.0mma
KC-1MRD
KC-DAR
IER-2
2 KC-DAR
KC-1MRD
NP
4-tone chime
M
Tilt camera control
2 2
A1 A2
M
N
H A1 A2 S S + –
1 E
N
EL-10S
H l Run audio/video wires in a separate jacketed cable from door release wires. N : PS-2420/S/UL H : AC transformer
Cable Vinyl jacketed, PE(polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed.
9
• Hands-free monitoring audio & image of door • Video door station's white LED illumination automatically turns on in the darkness • Locator LED backlight on CALL button
Lineup
KAW-D
AC-10S
Picture memory unit m P.21
30k angled box m P.22
Access control keypad, surface mount m P.99
EL-10S
KA-DGR PANEL
Electric door strike m P.101
Stainless steel housing for KC-DAR
AC-10F
IER-2 Call extension m P.101
Boxed sets
Long distance adaptor m P.21
Unit dimensions
Image view area
KC-DAR
KC-DAR
KC-1MRD
124cm 83.5
195
83.5
140
130cm 111cm
185
88
61
83.5
120
122.5
Video monitor Scanning lines Image view area
29
KA-DGR PANEL
83.5
55.4
Night viewing Door release Wiring Distance
151
142
KAW-D
105
50cm
★
60cm ★
109
42
approximate
Specifications (KC-1MRD) Power source Power supply Communication
JBW-BA 108.5
IER-2
4.5
★
50cm
44
107
★
235cm
★
88
Access control keypad, flush mount m P.99
JBW-BA
KCS-1ARD: KC-DAR & KC-1MRD add appropriate power supply
105
VIDEO ENTRY SECURITY
KC-32EU
24V DC, 450mA. 50mA standby PS-2420S, PS-2420UL, PS-2420 Door calls in w/4-tone chime & image, 30 sec. timed. Lift handset to reply, 2-1/2 min. timed. In standby, press MONITOR to view and hear door. 4 inch TFT color LCD 525 lines Approx. 60cm horiz., 111~235cm vert. at 130cm high and 50cm from camera. White light projected up to 30cm from camera. The background scene beyond 30cm cannot be seen. 12V AC, 400mA. 2 parallel wires to door, non-polarized. KC-1MRD ~ door 50m(0.65mma) 100m(1.0mma) KC-1MRD ~ IER-2 50m(0.65mma) 100m(1.0mma)
30˚
10
Video Sentry Color Tilt DOOR
ROOM
1
3 KC-1GRD Door station
Features • • • •
VIDEO SENTRY COLOR TILT 1 door - 3 monitors INSTANT ON door audio & video All call type room calling 100m distance between monitors, looped
Master station
VIDEO ENTRY SECURITY
2
2
IER-2
2
2
Call extension m P.101
2
PT
KC-DAR Video door station
KC-1GRD Master station
2
PS24 PS24
Power supply PS-2420S PS-2420UL PS-2420 m P.104
Communication network
Wiring 100m / 1.0mma
100m / 1.0mma IER-2
KC-1HRD
4-tone chime
2
2
KC-1SD KC-DAR
KC-1HRD
KC-1GRD
KC-DAR
NP
KC-1GRD KC-1GRD
2
2
2 2
M
Tilt camera
2
2
N N
H
(1)
M
KC-1SD A
KC-1SD
KC-1HRD
A1 A2
A1 B1 A2 B2 + -
N
KC-1HRD
B
A1 B1 A2 B2
A
+ + -
N
EL-10S
B
A1 B1 A2 B2
or A
H
B A1
S S
1 E
A2
l Run audio/video wires in a separate jacketed cable from door release wires. N : PS-2420/S/UL H : AC transformer
Cable (1) All call type voice calling (from any). Communication on handsets individually.
11
Vinyl jacketed, PE (polyethylene) insulation cable is recommended. For other types of cables, normal operation and max. communication distance cannot be guaranteed.
• TILT camera control • Hands-free monitoring audio & image of door • Video door station's white LED illumination automatically turns on in the darkness
Lineup
Sub station
KA-DGR PANEL Stainless steel housing for KC-DAR
KC-1HRD
Access control keypad, surface mount m P.99
KC-1HRD
Sub master station
Sub master station
or
AC-10F
KAW-D
Access control keypad, flush mount m P.99
30k angled box m P.22
or 2
2
2
KC-1SD*
JBW-BA
KC-1SD*
Audio sub station *Not available in Europe
Audio sub station *Not available in Europe
Long distance adaptor mP.21
EL-10S
KC-32EU
MCW-S
Electric door strike m P.101
Picture memory unit m P.21
KC-1GRD, KC-1HRD
★
KC-DAR
KC-1SD
124cm
★
50cm
235cm 83.5
210
83.5
195
130cm
★
111cm 50cm
100
KC-DAR
88
44
83.5 29
83.5
4.5
55.4
61
Power supply Video monitor Scanning lines Communication
151
142 107
105
122.5
KA-DGR PANEL
KAW-D
Power source Consumption
JBW-BA 120
140
83.5
IER-2
109
60cm★ ★
approximate
Specifications (KC-1GRD)
74
108.5
88
105
Monitor desk stand mP.22
Image view area
Unit dimensions
185
AC-10S
VIDEO ENTRY SECURITY
2
42
Image view area
30˚
Night viewing Door release Wiring
Distance
24V DC KC-1GRD: 450mA. 70mA standby. KC-1HRD: 200mA. 50mA standby. KC-1SD: 70mA. 50mA standby. PS-2420S, PS-2420UL, PS-2420 4 inch TFT color LCD 525 lines Door calls in w/4-tone chime, 30 sec. Hear and see door instantly. Pick up at any station to reply, 2-1/2 min. timed. Recycle with MONITOR. Monitor hands-free audio & image of door w/MONITOR. Press ALL CALL to call the other w/pretone & voice. Lift either handset to reply. Approx. 60cm Horiz., 111~235cm Vert. at 50cm in front of camera at 130cm high. Up to 30cm from camera, with white LED projected. Background scene beyond 30cm cannot be seen. Contact rating: 12V AC, 400mA. 2 parallel wires to door, non-polarized. 2 wires in loop between monitors, plus 2 wires separately run from power supply. KC-1GRD ~ door 50m(0.65mma) 100m(1.0mma) KC-1GRD ~ farthest sub 50m(0.65mma) 100m(1.0mma) KC-1GRD ~ IER-2 50m(0.65mma) 100m(1.0mma)
12
Video Sentry Color Tilt Features
DOOR
ROOM
3
5 KB-3MRD
• • • • •
Door station
3 doors & 5 monitors w/TILT camera control. INSTANT ON audio & image of door. Selective calling or All Call. Audio sub station in lieu of monitor. Optional audio door at 3rd entry.
Master station
VIDEO ENTRY SECURITY
KB-DAR Video door station
2 2
2 PT
2
IER-2
2
KB-DAR Video door station
Call extension m P.101
2
KB-3MRD Master station
2 or PS24
KB-DAR Video door station
IF-DA Audio door station
Power supply PS-2420S PS-2420UL
PS-2420 m P.104
Communication network
Wiring 200m / 1.0mma
KB-DAR
KB-DAR
KB-3HRD
4-tone chime Tilt camera control
M KB-DAR
IER-2
KB-3HRD
2
NP 2
KB-3MRD (1)
2-tone chime Tilt camera control
KB-3HRD
KB-3MRD
2 KB-3HRD4 2
2
2
2
2 KB-3SD KB-3HRD
2 2
M H
KB-DAR
2
A1 A2
KB-3SD
2A1 + 2A2 A1 A2
IF-DA
Cable
B
1A1 B1 1A2 B2
N N
2
A
B
1A1 B1 1A2 B2
A
B
1A1 B1 1A2 B2
A
+ + -
+ -
N 1 E
or A
H
B
1A1 B1 1A2 B2
+ -
S S
EL-10S
Cable specified for wiring to both door and inside stations l 0.65mma to 1.2mma dia. l PE(polyethylene) insulation & vinyl jacketed cable l Attenuation: less than -6.5dB at 10MHz./100m length. l Solid copper conductor. l Line impedance: c75 ohm (less than 100 ohm at the highest).
3A1 3A2 D1 E1
(1) Selective Call or All Call type voice calling (from any). Communication on handsets individually.
2
KB-3SD
1A1 B1 1A2 B2 A1 A2
2
NN N A
8-tone chime Tilt camera control
13
100m / 1.0mma
b1 b2 b3 E
B
A1 B1 A2 B2
(1)
l D1, E1 : for IF-DA door station instead of third KB-DAR. l Run audio/video wires in a separate jacketed cable from door release wires. N : PS-2420/S/UL H : AC transformer (1) External light control
• • • •
Push chime or receiver volume control. Optional selective door release with RY-3DL. Hands-free monitoring audio & image of door. Video door station's white LED illumination automatically turns on in the darkness.
Lineup
Sub station
KB-3HRD
KB-3HRD
KB-3HRD
Sub master station
Sub master station
Sub master station
Sub master station
2
2
KC-32EU Picture memory unit m P.21
2
AC-10S Access control keypad, surface mount m P.99
or
KA-DGR PANEL Stainless steel housing for KB-DAR
2
AC-10F Access control keypad, flush mount m P.99
VIDEO ENTRY SECURITY
KB-3HRD
2
KB-3SD
2
Audio sub station max. 2pcs
2 PS24
KAW-D 30k angled box m P.22
EL-10S
RY-3DL
MAW-B
Door release adaptor m P.21
Auxiliary light control relay m P.102
Electric door strike m P.101
2
PS24
Unit dimensions
Image view area KB-3MRD, KB-3HRD
KB-DAR
★
124cm
KB-DAR
★
50cm
235cm ★
111cm
83.5
195
140
83.5
130cm
50cm
105
approximate
44
Specifications (KB-3MRD)
KB-3SD 185
84
Power source Consumption
83.5
120
210
83.5
IER-2
Power supply Video monitor Scanning lines Communication
29
88 100
74
KAW-D
151
142
KA-DGR PANEL
107 109
60cm★ ★
42
105
83.5
4.5
55.4
Image view area
30˚
Night viewing Door release Wiring
Distance
24V DC KB-3MRD: max.710mA, 230mA standby KB-3HRD: max. 260mA, 80mA standby KB-3SD: max 85mA, 50mA standby PS-2420S, PS-2420UL, PS-2420 4 inch TFT color LCD 525 lines Door calls in w/4-tone chime, 30 sec. Hear and see door instantly. Pick up at any station to reply, 2-1/2 min. timed. Recycle with MONITOR. Monitor audio& image of door hands-free w/MONITOR. Press a station selector and call by voice. The called station replies hands-free. Lifting handset, press ALL CALL button to call the other stations w/pretone and voice. Approx. 60cm Horiz., 111~235cm Vert. at 130cm high & at 50cm in front of camera. Up to 30cm from camera, with white LED projected. Background scene beyond 30cm cannot be seen. Contact rating: 12V AC, 400mA 2 parallel wires to door, non-polarized. 2 wires in loop between monitors, plus 2 wires separately run from power supply. KB-3MRD ~ door 100m(0.65mma) 200m(1.0mma) KB-3MRD ~ farthest sub 50m(0.65mma) 100m(1.0mma) KB-3MRD ~ IER-2 50m(0.65mma) 100m(1.0mma)
14
Hands-free Color Video Intercom MASTER
8
Features
DOOR
• Up to 120 video entrance stations and 8 master stations • All wired on CAT5e, homerun cabling • Total hands-free, auto-voice actuation, communication or Press-to-talk operataion
120 AX
Door station
Central exchange unit Cat5e
VIDEO ENTRY SECURITY
2 Cat5e
PT
2 PS24
AX-084C
PS24
Central exchange unit, 4 masters and 8 doors
AX-248C (Photo)
AX-DV
Central exchange unit, 8 masters and 24 doors
Color video door station surface mount
AX-DV-P
AX-DM
Color video door station w/space for embed proximity reader
Audio door station Mullion type
AX-320C Add-on exchange unit, 32 doors
PT
AX-DVF Color video door station flush mount
AX-DVF-P
IE-JA
Color video door station w/space for embed proximity reader
Audio door station
Communication network
Power supply PS-2420S PS-2420UL m P.104 PS-2420
Wiring 300m
300m Master #1 AX-8MV
Door #1 AX-DV
Cat5e
Cat5e
RJ-45
AX-DV
RJ-45
Cat5e
Cat5e
RJ-45
AX-8MV
Master #8 AX-8MV
AX-248C
Door #24 AX-DVF
2
AX-8MV
2
AX-DVF
Door #1 AX-DV
RJ-45
N N
Master #1 AX-8MV
RJ-45 Cat5e
M
Video signal
AX-DM
AX-248C
RJ-45
H + -+-
Cat5e Door #24 AX-DVF
N N
Cat5e
Monitor
RJ-45
M
Cat5e
H
Calling & communication (w/video from door) Door release
15
N : PS-2420S, PS-2420UL, PS-2420 H : AC transformer
RJ-45
Master #8 AX-8MV
• • • • • •
• • • • • • •
Two talk channels and two video channels Communication privacy Masters available with 3.5 inch color TFT LCD Selective door release Master-to-master selective calling and All Call Standard or Priority call levels from door stations
Scan monitoring:Hands-free audio/visual monitoring Video output from CEU and AX-8MV Integrate with CCTV, Access control etc. PC interface for programming and event logging Rack or wall mountable CEU Compatible with IE Series door stations Optional features: headset, footswitch, and PC remote control
Lineup
Master station
EL-10S Electric door strike m P.101
AX-8MV
AX-16SW
8-call color monitor master station
16-call add-on selector
Cat5e
VIDEO ENTRY SECURITY
Cat5e
AC-10S Access control keypad, surface mount m P.99
AX-8M
AX-8MV, AX-16SW
8-call audio master station
AC-10F Access control keypad, flush mount m P.99
Unit dimensions
Image view area
AX-8MV
AX-8M
• AX-DV, AX-DVF, AX-DV-P, AX-DVF-P ★
175
175
185cm 65cm
★ ★
50cm
120cm 150cm 194
63
63
194
95cm
50cm ★
AX-16SW
AX-084C, AX-248C
AX-320C
86
Power source Power supply Current consumption
88 85
Calling
63
AX-DV
AX-DV-P
AX-DVF
246
245
195
Communication
100
Video monitor Scaning lines Night viewing
25 146 100
2 45
25
Door release contact Outside video output
IF-DA
AX-DM
130
AX-DVF-P
295
160
1-gang
98
28
IE-JA
146
22.5
115
43
2-gang
2 45 116
approximate
Specifications (AX) 420 426
88 85
175
420 426
★
Wiring Wiring distance
24V DC, 2A (Two Power supplies per video system) PS-2420S, PS-2420UL, PS-2420 AX-084C: Video (Max.) 650mA, Audio (Max.) 700mA AX-248C: Video (Max.) 1150mA, Audio (Max.) 1250mA AX-320C: Video (Max.) 280mA, Audio (Max.) 180mA Normal call: an intermittent tremolo Priority call: a rapid intermittent tremolo Approx. 10-600 sec. or infinite AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. Approx. 30-600 sec. 3.5 inch direct view TFT color LCD 525 lines Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 0.5A AX-084C, 248C: NTSC standard 1Vpp (0.7-1.4Vpp) BNC x 2 Switching signal: Open collector output 24V DC, 30mA RJ-45 x 2 AX-8MV: NTSC standard 1Vpp (0.7-1.4Vpp) Homerun CAT5e wire to CEU CEU to door: 300m (CAT5e) CEU to master: 300m (CAT5e)
10
16
Wide Angle Video Sentry DOOR
ROOM
1
3 MK-1GD
Door station
Master station
Features • • • • • •
VIDEO ENTRY SECURITY
4
MK-2DA
2
Sub master station
2
MK-1GD Master station
or
Two-call video door station m P.22
MK-1HD
PS18
PT
Video door station
Lineup
Sub station
2
MK-DV
Single-door, three-monitor system with door release Instant voice call-in with image Internal handset communication. All call type voice calling Transfer of door call-in. (Image of caller remains on) Fixed camera, wide angle viewing Infrared LED's projected on callers at 50cm in the darkness
MK-2DG Two-call video door station m P.22
or
4
4
IER-2 Call extension m P.101
or
MK-2SD
Video door station
Video door station
Electric door strike m P.101
KAW-D 30k angled box m P.22
MK-1HD or
MK-DH
MK-DVF
EL-10S
Audio sub master station
Sub master station
4 Boxed sets MKS-1GD: MK-1GD & MK-DH MKS-1GDV: MK-1GD & MK-DV MKS-1GDVF: MK-1GD & MK-DVF
MK-2SD Audio sub master station
Add appropriate power supply
KC-32EU
MKW-P
Picture memory unit m P.21
MK-DV Gang box mounting plate
Power supply PS-1820S PS-1820UL PS-1820 m P.104 Communication network
Wiring 200m / 1.0mma
75m / 1.0mma
MK-1HD
MK-DV
MK-2SD
2
2 4-tone chime
M
M
MK-2SD
A1 A2
H
NP
MK-1HD
Instant voice calling w/image. All call with pre-tone/voice. Internal communication on handsets
EL-10S
Unit dimensions MK-1GD, MK-1HD
4
4
MK-1GD
MK-DV
MK-1HD
MK-1HD
IER-2
MK-1GD
H
2
U
DOOR SUB B1 A1 A2 B2 NP CALL EXT IER-2 1 S E S RLSE. DC18V + L L P
U
SUB IN OUT B1 B1 B2 B2
NP
DC18V IN OUT + +
DC18V IN OUT + + SW1 OFF
SUB IN OUT B1 B1 B2 B2
P
SW1 ON
l MK-2SD may be wired in the same manner as MK-1HD. U : PS-1820S, PS-1820UL, PS-1820 H : AC transformer SW1-ON Terminated
MK-2SD
200
210
Specifications 60/ 83.5
Power sourse Consumption
60/ 83.5
Power supply Calling Communicarion 69
215 MK-DV
89
61
130
MK-DH
209
173
MK-DVF
83.5
98
98
17
27
135
45 5.5
35
Video monitor Scanning lines Minimum illumination Door release Wiring Distance
18V DC MK-1GD : (Max.) 650mA, MK-1HD : (Max.) 450mA MK-2SD : (Max.) 150mA PS-1820S, PS-1820UL, PS-1820 Chime, audio & image, approx. 45 sec. Simultaneous with handsets, approx. 2-1/2 min. Extend w/MONITOR. All call type voice calling, common talk. 4 inch direct view flat CRT 525 lines 1 Lux or less at 30cm distance 12V AC, 0.4A dry-closure contact(L, L) 2 conductors to door 4 conductors betweens room stations Door to MK-1GD 200m(1.0mma) MK-1GD to farthest sub 75m(1.0mma) MK-1GD to PS18 10m(1.0mma)
PanTilt Video Sentry DOOR
ROOM
2
3 MK-2MCD
Door station
Master station
Features • • • • • •
Two-PanTilt door, three-monitor system with door release Instant voice call-in with image Internal handset communication. All call type voice calling Transfer of door call-in. Image of a caller stays on Optional audio door station at second entrance Infrared LED's projected on callers at 50cm in the darkness
Lineup
Sub station
2
4
KC-32EU
PT
MK-DBC Video door station
Sub master station
2
MK-2MCD Master station
2
4
MK-D*
Picture memory Audio door unit station m P.21 *Not available in Europe
MK-2HCD
PS18
or 4
VIDEO ENTRY SECURITY
2
IER-2 Call extension m P.101
MK-2SD Audio sub station
EL-10S
RY-3DL
Electric door strike m P.101
Door release adaptor m P.21
MKW-R
KAW-D
Surface mount box for MK-DBC
30kangled box m P.22
MK-2HCD or or
Sub master station
or
MK-DGC
4
Video door station
MK-DAC
MK-DH
Video door station
Video door station Fixed camera
MK-2SD Audio sub station
Power supply PS-1820S PS-1820UL PS-1820 m P.104
Communication network
Wiring 100m / 1.0mma
MK-DBC
MK-2SD
4-tone chime MK-2MCD
MK-DGC
PanTilt control
IER-2
M
MK-DGC MK-D
H
MK-DGC
M
A1 A2
1 2
MK-2HCD
NP
MK-D NP
Instant voice calling w/image. Pan/tilt camera from any inside monitor station. All call initiated w/pre-tone/voice. Internal communication on handsets.
EL-10S
MK-2SD
92
170
200
210
Power sourse Consumption Power supply Calling Communicarion
63
130
89
98
83.5
92
130
MK-DAC
83.5
MK-D
44 47.5
98
35
130
69
115 12.5 19 37
SUB
SUB
IN OUT
IN OUT
B1 B1 B2 B2
NP
DC18V
RLSE. DC18V + L L
DC18V
IN OUT
+
U
P
IN OUT
+
SW1
B1 B1 B2 B2
+
P
+
SW1 ON
Specifications
12.5 19 37 MK-DH
MK-DBC
U
l MK-2SD may be wired in the same manner as MK-2HCD. U : PS-1820S, PS-1820UL, PS-1820 H : AC transformer SW1-ON Terminated
MK-DGC
114
215
2
OFF
Unit dimensions MK-2MCD, MK-2HCD
H
MK-2HCD 4
4
DOOR1 SUB 1A1 B1 1A2 B2 NP CALL DOOR2 EXT IER-2 1 2A1 S E S 2A2
NP
A1 A2
MK-2SD
MK-2HCD
MK-2MCD 2
2 2
MK-D MK-DBC
2-tone chime
172
75m / 1.0mma
MK-2HCD
MK-DBC
98
83.5 28
Video monitor Scanning lines Minimum illumination Door release Wiring Distance
18V DC MK-2MCD: (Max.) 750mA, MK-2HCD: (Max.) 450mA MK-2SD: (Max.) 70mA PS-1820S, PS-1820UL, PS-1820 Chime, audio & image, approx. 45 sec. Simultaneous with handsets, approx. 2-1/2 min. Extend w/MONITOR. All call type voice calling, common talk. 4 inch direct view flat CRT 525 lines 1 Lux or less at 30cm distance 12V AC, 0.4A dry-closure contact(L, L) 2 conductors to door 4 conductors between inside stations Door to MK-2MCD 100m(1.0mma) MK-2MCD to farthest sub 75m(1.0mma) MK-2MCD to PS18 10m(1.0mma)
18
PanTilt Video Sentry DOOR
ROOM
1
6
*Not available in Europe Scheduled to stop production
MY-CU & IE-8MD
Door station
Master station
Features • • • • •
6 monitors & single PanTilt door Additional audio door station Add-on monitors with additional power supply Answer door from any room station Selective calling or All Call between room stations
Lineup
Sub station
VIDEO ENTRY SECURITY
6
2
IE-8HD
4
EL-10S
6-call sub master
Electric door strike m P.101
MYH-CU Sub video-monitor
MK-DBC Video door station
5
PS18
IE-8MD
4
6-call master
IE-8HD MYH-CU
MY-CU Main video monitor
2
MYW-BA
PS18
6
Long distance adaptor m P.22
4
IF-DA Door station
IE-8HD MYH-CU RY-AC/A External signaling relay m P.101
4
6
IE-8HD MYH-CU
6 4
Power supply PS-1820S PS-1820UL PS-1820 m P.104
Communication network IE-8MD & MY-CU
TAR-3 External signaling relay m P.102
IE-8HD MYH-CU
Wiring 100m / 1.0mma 75m / 1.0mma IE-8HD
IE-8HD IE-8MD & MY-CU
MK-DBC
MK-DBC
2 2
M
M
M
IF-DA
IF-DA
A1 A2
M
IE-8HD / MYH-CU
IE-8HD
U
210
IE-8MD & MY-CU IE-8HD & MYH-CU
110 155
Specifications (MY-CU & IE-8MD) Power source Power supply Communication Wiring Distance
19
83.5
Unit dimensions
79
EL-10S
6
6
4
4
4
4
MYH-CU 1
MYH-CU 2
3
4
5
1A1 B1 1A2 B2 U1 U2
1A1 B1 1A2 B2 U1 U2
1A1 B1 1A2 B2 U1 U2
1A1 B1 1A2 B2 U1 U2
1A1 B1 1A2 B2 U1 U2
1A1 B1 1A2 B2 U1 U2
+ –
+
+
+
+
–
+ –
ON (OFF)
OFF
OFF
OFF
ON
1 2 3 4
1 2 3 4
1 2 3 4
–
D1 D2 E
EL-10S
6
4
MY-CU
IE-8HD
4 & 2-tone chime. Pan and tilt camera on any monitor. Selective call or All call on inside stations.
IE-8HD & MYH-CU5 6 5
+ –
D1 E1 D2 E2
EL EL SL SL
1 2 3 4
1 2
–
–
U 1 2 3 4
1 2 3 4
H
l Use a power supply for additional monitors MYH-CUs. l Run audio/video wires in a separate jacketed cable from door release wires. U : PS-1820/S/UL H : AC transformer
18V DC, 1.8A, IE-8MD: 12~18V DC, 0.5A, MY-CU: 18V DC, 0.9A, MYH-CU: 18V DC, 0.4A PS-1820S, PS-1820UL, PS-1820 Door calls in w/4 or 2-tone chime, 45 sec. Lift any handset to reply, 2-1/2 min. Press MONITOR to reactivate. Cut chime tone if needed. 2 parallel wires to door, non-polarized. 6 wires, monitors in loop. MY-CU to P/T door 50m(0.65mma) 100m(1.0mma), MY-CU to MYH-CU1 35m(0.65mma) 75m(1.0mma)
Master Sentry DOOR
Features
ROOM
3
8 LEF-C Video
Door station
Scheduled to stop production
*Not available in Europe
Adaptor
• • • • • •
Semi-flush residential communication system One to three PanTilt video doors Door release activation All Call and music distribution through stations Audio door & room sub stations for varied systems Any combination of doors and rooms up to 11 total stations
Master station
2
Lineup
6
5 common 2/door
2
LEF-5C
LE-C
5-call master m P.63
MK-DGC
Sub station m P.65
LE-CN
Video door station
Privacy sub (Photo) m P.65
PS18
MYW-P3L
PS12
MYH-CUB
3 PanTilt door adaptor
LE-B
Semiflush video-monitor
LEF-10C 10-call master
3-call master m P.63
5 common 2/door 1/station
MK-DBC
LE-BN Privacy sub m P.65
6
MYW-P1L
Video door station
Sub station m P.65
LEF-3C
1 PanTilt door adaptor
MYH-CUB
LEF-1C
EL-10S
All call sub master m P.65
Electric door strike m P.101
VIDEO ENTRY SECURITY
2
Semiflush video-monitor
LEF-10C
BG-10C
RY-PA
10-call master
MK-DAC
Door release relay
All call, chime & music adaptor m P.65
LE-D
LE-DA
Sub station m P.65
Sub station m P.65
Video door station
Power supply PS-1820S PS-1820UL PS-1820 m P.104 PS-1225S PS-1225UL PS-1225 m P.103
Communication network MK-DGC Chime tone & LED. 1.
Wiring MK-DGC
MYH-CUB &LEF-10C
LEF-10C
6
NP
MK-DGC
All call or selective call Varies
1A1 1A2
B1 B2
A1 A2
2A1 2A2
U1 U2 + –
A1 A2
3A1 3A2
2. MYH-CUB &LEF-10C
MK-DGC
Door 1 only w/MYW-P1L (RY-PA req’d for door release) Doors 1~3 w/MYW-P3L & selective door release. (RY-PA’s req’d for door release)
Unit dimensions
PT
MYH-CUB
20
200
240
200
238 200
110 150
15.5 20 40
C 2 3 4 5 6 7 8 9 10 E R Y + –
1 C 3 4 5 6 7 8 9 10 E R Y + –
L K8 K9 K10
L K8 K9 K10
(*1)
+ –
PS12
(*2)
(*1)Add’l video monitors with another PS-1820 power supply (*2)Intercom wiring varies by system. Power source Power supply Communication
Wiring 43
RY
B1 B2 U1 U2 + –
Q : RY-PA H : AC transformer U : PS-1820/S/UL T : PS-1225/S/UL (2.5A)
83.5
230 155
LB LC
A1 A2
U1 U2 + –
Specifications (LEF-C) 33.5 40
MYW-P3L
RY
DC DB DA E R
EL2 KC KB KA
20
LEF-5C/10C
LA
B1 B2
PS18
3. EL-10S
23 A1 A2
LEF-10C
RY
6
11
PanTilt viewing. A1 A2
MYH-CUB/ LEF-10C
MYH-CUB/ LEF-10C
MYW-P3L (ea.) 2
Distance
12V DC, 300mA per station. PS-1225S, PS-1225UL, PS-1225 Momentary tone & 20 sec. LED. Depress a station button and press Talk/Listen button. Station LED and occupied LED remain lit while in use. Single talk channel. 9 common + total No. of stations in system (for all features except K terminal options) Between farthest stations 200m(0.65mma)300m(0.8mma)
20
Video Accessories Picture memory unit Features
Wiring
VIDEO ENTRY SECURITY
l Easy add-on to present or new system, color or black & white l 4 pictures in 1 frame (16 frames), 16, 32 or 60 individual picture save mode l Max. 8 pictures stored in memory
IER-2 KC-DAR
KC-32EU KC-1GRD 2
2 2
M
N
KC-1MRD, KC-1GRD, KB-3MRD, MK-1GD, MK-2MCD
NP
A1 A2
A1 A2
B1 B2
Unit dimensions
KC-32EU Picture memory unit
KC-32EU
2
2
2
A
NP
1A1 B1 1A2 B2
N
EL-10S
2
N
H
Used for
KC-1HRD
KC-1HRD
2
B
1A1 B1 1A2 B2
A
NP
N
195
IER-2
80
1 E
S S
83.5
H : AC transformer
N : PS-2410S, PS-2420UL, PS-2420
54.5
Single-gang mounting
Specifications (KC-32EU)
KC-1GRD
Power source Power supply Channel Wiring
KC-32EU
Master station Picture memory unit Wiring distance
18V DC, 230mA, 24V DC, 160mA PS-1820S, PS-1820UL, PS-1820, PS-2420S, PS-2420UL, PS-2420 One video door per unit 2 parallel wires to door (NP). 2 wires to Master (Polarized). KC-32EU to door 50m(0.65mma) 100m(1.0mma) KC-32EU to master 25m(0.65mma) 5m(1.0mma) KC-32EU to Power supply 10m(1.0mma) (20m w/1.2mma)
Long distance adaptor for color Features
Wiring
l When JA, JB, KC color video door station is more than 100m to max. 350m away, or JF color video door station is more than 100m to max. 300m away. l One required for each door station.
250m / 1.2mma
JF-DV
JBW-BA
JBW-BA
1.0mma to 1.2mma. Solid copper conductor PE insulation (not PVC).
Specifications 18VDC, 24VDC PS-1820S, PS-1820UL, PS-1820, PS-2420S, PS-2420UL, PS-2420 of system or separate 120mA 2 parallel wires to ea. door & master. JA, KC door~JBW-BA 100m~300m(1.2mma) JBW-BA~JA, KC master 50m(1.2mma) JF door~JBW-BA 100m~250m(1.2mma) JBW-BA~JF master/JF-1FD/JF-1SD 50m(1.2mma) JBW-BA~PS 50m(1.2mma)
Current consumption Wiring Distance
108.5
Long distance adaptor
61
122.5
C
A1 A2 + –
Cable
Power source
Unit dimensions
JF-2MED
A1 B1 A2 B2 + –
A1 A2
Used for KC-1MRD, KC-1GRD KC-32EUKC-1ARD/KC-1GRD JA-2MECD, JA-2MCD JF-1MD, JF-2MED
50m / 1.2mma
JBW-BA
Selective door release adaptor Wiring
Features l Selective door release with one button l Door release contacts release the door where communication is established. l Normally open contacts for electric strike. Normally closed contacts to work with magnetic locks.
EL-10S
RY-3DL L1 C1 L1
EL-10S L2 C2 L2 EL-10S L3 C3 L3
Used for KB-3MRD, MK-2MCD, IE-2AD(U) JF-2MED RY-3DL
H
Specifications
Door release adaptor
Power source Power supply Relay contacts
140 74
42
Wiring distance
21
N
GR: Green BL: Blue PL: Purple OG: Orange YL: Yellow H : AC transformer N : PS-2420/S/UL
Unit dimensions RY-3DL
KB-3MRD CN12 GR BL PL CN11 OG YL
b1 b2 b3 L D1 E D2
B
1A1 B1 1A2 B2
12~24V DC, 30mA 12~16V AC, 60mA PS-2420/S/UL; PS-1820/S/UL; PS-1225/S/UL; AC trans. Normally open output. 1A at 50V AC. 1A at 30V DC (for other types, use matching relay) Master to RY-3DL 50m(0.65mma) 100m(1.0mma) RY-3DL to EL-10S 50m(0.65mma) 100m(1.0mma)
30kangle box Features
Image view area
l 30k Angle Box for mounting video door station to position door camera to view visitors better. l Designed for 1-gang surface mounting.
KAW-D
30
Used for
KC-DAR
KC-DAR, KB-DAR, MK-DH
m
50c
★
m
60c
VIDEO ENTRY SECURITY
Unit dimensions 142
KAW-D
KAW-D
*Figure is approximate.
83.5
30k angled box 107
4.5
55.4
30˚
105
Desk-top stand Used for MK-1GD, MK-1HD MK-2MCD, MK-2HCD KC, KB monitors
MCW-S Monitor desk stand
Dual-call door station for B&W Features
Cabling
Call two monitors (MK-1GD) selectively. Each monitor is powered by a separate power supply. l Wide-angle view l Camera angle adjuster (16k upward) l Backlit call buttons l Acrylic nameplates for engraving l While one monitor is in use, the other monitor is not operational.
MK-2DA
MK-2DG
Two-call video door station
Two-call video door station
MK-2DG
MK-2DA
MK-2DG PANEL 206
189
Panel only
35
119
120
U
4
MK-2DA 2 2
4
M
U
PT
U : PS-1820S, PS-1820UL H : AC transformer
Specifications Power source Camera Scanning lines Minimum illumination Image view area Wiring Wiring distance
Unit dimensions
MK-2SD
MK-1GD
34
Supplied by monitor in use CCD camera w/infrared LED’s 525 lines 1 Lux at 50cm from camera 70cm Vert. x 110cm Horiz. at 50cm 2 parallel wires, polarized Door to monitor 50m(0.65mma) 100m(1.0mma)
Long distance adaptor for B&W Features
Cabling
l When B&W video door station is more than 100m to max. 300m away. l Separate power supply allows mounting MYW-BA up to 50m away from master station or adaptor.
U : PS-1820S, PS-1820UL, PS-1820
Used for
Cable
MK-1GD, MK-2MCD MY-CU w/IE-8MD or TD-H/B MYW-P1L or MYW-P3L w/LEF LEF-C, TB-ADM10 w/TC-M
Unit dimensions MYW-BA
MYW-BA 2
190
Long distance adaptor
42
4
MK-1GD
U
Impedance: 90d. Permitted closed loop DC resistance: 9.9d or less. PE insulation (not PVC).
Specifications Power source Current consumption Wiring Distance
MYW-BA
80
MK-DV
PS-1820/S/UL of system or separate 250mA 1mA standby 2 parallel wires to ea. door & master. MYW-BA~door 200m(1.0mma) 300m(1.2mma) MYW-BA~master 50m(1.0 or 1.2mma) MYW-BA~PS 7m(1.0mma) 10m(1.2mma)
22
Two-Wire Electric Lock Door Phone DOOR
ROOM
1
1 DA-1AS Lineup
Boxed set
DA-1AS
DA-1AG
Kit box (silver color)
Kit box (gray color)
EL-10S
AC-10S
Electric door strike m P.101
Access control keypad, surface mount m P.99
DAR-1 Call extension
AUDIO ENTRY SECURITY
Door station silver panel
DA-1MD
Door station gray panel
DA-1MD Master station
AC-10F Access control keypad, flush mount m P.99
Master station
DAW-P
*Add an appropriate power supply.
Door station mounting plate (83.5mm)
*Add an appropriate power supply.
Power supply PT-1211D PT-1211C m P.103 Features
Wiring
l Two-wire system including door release l Door release wired to door station, requiring no power transformer l User-optional function button l Call tone MUTE with indicator l Call extension sounder
310m / 1.0mma 155m / 1.0mma DA-1MD
DA-1DS DA-1DG
M
2
DAR-1
2 NP 2
2
P
Communication network
PT-1211D/C (1) EL-10S
DA-1DS, DA-1DG
DA-1MD DAR-1
(2)
L L
~ ~
D E
D E
PT-1211D/ PT-1211C
S SE SW SW
M
Unit dimensions DA-1MD 89
22
200
175
100
61
Specifications (DA-1AS, G) Power source Power supply Communication Wiring Distance
23
(3)
l Place PT-1211D/C inside electrical enclosure and connect to breaker, less than 16A. l Do not use PT-1211D/C for any other equipment. l Terminals SW, SW; Dry-closure contact 18V AC, 40mA to connect user-optional function (Gate, Light, Garage, Proximity Access Control, etc.) (1) External device Relay/Controller (2) Door release (16V AC, 20d or more) (3) User-optional function (18V AC, 40mA)
Hold down gCALLh button to ring inside station.
DA-1DS, DA-1DG
S SE
15V AC PT-1211D, PT-1211C Press and hold down Button to call. 2 wires, throughout system: PS - Master - Door - Door release PT-1211D/C ~ Door rlse. 110m(0.6mma) 200m(0.8mma) 310m(1.0mma) PT-1211D/C ~ DA-1MD 55m(0.6mma) 100m(0.8mma) 155m(1.0mma)
Chime Tone Intercom DOOR
ROOM
1
1 C-123L/A
Door station
Master station
Lineup
AC-10S Access control keypad, surface mount m P.99
C-D Door station
C-ML/A Master station Access control keypad, flush mount m P.99
C-123L/A Chime-Com boxed set
Power supply PS-0602D PS-0602C or Batteries
EL-10S Electric door strike m P.101
m P.103
Features
Wiring
l Open voice door answering with door release control l Adjustable communication volume l Automatically turns off l Battery or DC power supply
AUDIO ENTRY SECURITY
AC-10F
Boxed set
115m / 0.8mma C-ML/A
C-D 2 NP
M Communication network
1 E + –
1 E EL-10S
W
L L
H
C-ML/A
C-D
H : AC transformer W : PS-0602D, PS-0602C
M
Specifications (C-123L/A) Power source Power supply Communication
Unit dimensions C-D
C-ML/A
Wiring
88
83.5
190
120
83.5
Distance
6V DC, 85mA PS-0602D, PS-0602C or Batteries gCh(SUM-2) x 4 pcs. Door calls in w/2-tone chime, not adjustable. Press TALK button to reply, release to listen. Power automatically shuts off circuit. 2 parallel wires to door, non-polarized (+ 2 for EL-10S). Master to door 75m(0.65mma) 115m(0.8mma)
29 130
44
24
Chime Tone Intercom DOOR
ROOM
1
1 TCS-MH Door station
Master station
TC-DC Door station
Boxed set
AUDIO ENTRY SECURITY
TCS-MH Chime-Phone set
TC-MH Master station
Features
Wiring
l Chime-phone intercom set, battery-operated l Adjustable chime volume l Battery status indicator
230m / 0.8mma TC-MH TC-DC 2 P.
Communication network 1 2
1 2
R
TC-MH TC-DC
R : Batteries P. Polarized
Specifications (TCS-MH) Power source Power supply Communication
Unit dimensions
28 80
25
83.5
210
130 98
Wiring Distance
TC-MH
83.5
TC-DC
58
6V DC, 70mA Batteries gAAh(SUM-3) x 4 pcs Door calls in w/2-tone chime, adjustable. Pick up to reply. 2 parallel wires, polarized. TC-MH to door 150m(0.65mma) 230m(0.8mma)
Chime Tone Intercom DOOR
ROOM
1 IE-1AD(U)
1
Door station
Master station
Lineup
IF-DA
EL-10S
AC-10S
Electric door strike m P.101
Access control keypad, surface mount m P.99
Door station m P.30
IER-2 AC-10F Access control keypad, flush mount m P.99
TAR-3
Power supply
IE-1AD(U)
12~24V DC power supply 12~16V AC transformer
Master station
Features
External signaling relay m P.102
Wiring
l Chime tone intercom for 2 locations l Door release button l AC or DC power source
360m / 1.0mma IE-1AD(U) IF-DA
IER-2 2 NP
1 2
1 2
Communication network
2
2
M
EL-10S
H
IE-1AD(U)
IF-DA
AUDIO ENTRY SECURITY
Call extension m P.101
WH
1 E
L L + –
IER-2
l Run audio wires in a separate jacketed cable from door release wires. H : AC transformer WH : White(2)
M
Specifications (IE-1AD(U)) Power source Power supply Communication
Unit dimensions IF-DA 130
IE-1AD(U)
98
Door release Wiring
210
83.5
83.5
Distance
12~16V AC, 180mA 12~24V DC, 160mA AC transformer (for IE & EL-10S), PS-1225/S/UL. Door calls in w/4-tone chime, adjustable. Pick up handset to reply. Contact rating: 24V AC/DC, 500mA 2 parallel wires, non-polarized (+2 for EL-10S) IE-1AD(U) to door 150m(0.65mma) 360m(1.0mma)
28
80
58
26
Chime Tone Intercom DOOR
ROOM
3 IE-1GD(U)
1 Door station
Master station
Sub station
Lineup
IE-JA Door station m P.30
AUDIO ENTRY SECURITY
Power supply
IE-1GD(U)
IEH-1CD
Master station
Sub master station
AC-10S
Electric door strike m P.101
Access control keypad, surface mount m P.99
IER-2
AC-10F
Call extension m P.101
Access control keypad, flush mount m P.99
TAR-3 External signaling relay m P.102
12~24V DC power supply or 12~16V AC transformer
Features
EL-10S
Wiring
l 3-station chime tone intercom with one door l Door release button l All call type room calling l Chime tone cutout at sub station l AC or DC power source
360m / 1.0mma
190m / 1.0mma
IE-1GD(U)
IEH-1CD
IEH-1CD IER-2
IE-JA 6
2
M
Communication network 1 2 IEH-1CD
2
2
D1 E1
IER-2
IE-JA IE-1GD(U) EL-10S
M
6
H
T R C E
T R C E
T R C E
L L
L L
L L
1 E
+ –
IEH-1CD
l Run audio wires in a separate jacketed cable from door release wires. H : AC transformer All Call type calling with pretone & voice
Specifications (IE-1GD(U))
Unit dimensions
Power source IE-1GD(U) IEH-1CD
115
IE-JA
116
Communication 210
83.5
83.5
Door release Wiring
10
100
27
Power supply
61
Distance
12~16V AC, 200mA 12~24V DC, 200mA AC transformer 12~16V, 550mA (for both IE & EL-10S), PS-1225/S/UL Door calls in w/4-tone chime to all stations. Chime can be cut out at sub(s). Pick up any station to reply. Press CALL to call other inside stations with pretone & voice. Contact rating: 24V AC/DC, 500mA 2 parallel wires to door, non-polarized. 6 wires in loop, between rooms. IE-1GD(U) to door 150m(0.65mma) 360m(1.0mma) Between rooms 75m(0.65mma) 190m(1.0mma)
Chime Tone Intercom DOOR
ROOM
2
3 IE-2A2DU
Door station
Master station
Sub station
Lineup
IE-JA Door station m P.30
Door station m P.30
IE-2A2DU
IE-2AD(U)
IEH-1CD
Master station, 2 door releases
Master station
Sub master station
Features
IER-2
AC-10F
Call extension m P.101
Access control keypad, flush mount m P.99
External signaling relay m P.102
2 door release
12~24V DC power supply 12~16V AC transformer
Access control keypad, surface mount m P.99
TAR-3
IEH-1C2D
Power supply
AC-10S
Electric door strike m P.101
Wiring
l 3-station chime tone intercom l 2 door stations w/door release l All call type room calling l Chime tone cutout at sub station l Door selective monitoring at master station l AC or DC power source
360m / 1.0mma
190m / 1.0mma IE-2A2DU
IE-JA 2
M
IEH-1C2D
8
IEH-1C2D 8
IER-2 2
2
M2 1 2
IER-2
IE-JA
IEH-1C2D
2 IF-DA
1 2
Communication network
AUDIO ENTRY SECURITY
IF-DA
EL-10S
EL-10S #1 IE-2A2DU EL-10S #2 H
D1 E1 D2 E2 T R C E
T R C E
T R C E
L L
L L
L L
BL
BL
+ –
BL
1 E
IF-DA
BL : Blue(2)
IEH-1C2D
( 1)
All call type voice calling between rooms (*1) Available in IE-2A2DU or IE-2AD(U) w/RY-3DL
Specifications (IE-2A2DU) Power source
Unit dimensions
Power supply
IE-JA 115
IE-2A2DU, IE-2AD(U)
Communication 83.5
10
210
83.5
83.5 210
116
IEH-1CD
130
IF-DA
98
H : AC transformer
83.5 28
Door release Wiring 100
68
100
61
Distance
12~16V AC, 200mA 12~24V DC, 200mA AC transformer 12~16V AC, 550mA (for both IE & EL-10S). PS-1225/S/UL Door calls in w/4- or 2-tone chime to all stations, 45 sec. Chime can be cut out at sub. Pick up any station handset to reply. Press CALL to call other stations with pretone & voice. Contact rating: 24V AC/DC, 500mA 2 parallel wires, non-polarized. 6 wires in loop, rooms. IE-2A2DU to door 150m(0.65mma) 360m(1.0mma) Between rooms 75m(0.65mma) 190m(1.0mma)
28
Chime Tone Intercom DOOR
ROOM
2
6 IE-8MD Door station
Master station
Lineup
Sub station
AC-10S
EL-10S
Access control keypad, surface mount m P.99
Electric door strike m P.101
IE-JA Door station m P.30
TAR-3
AUDIO ENTRY SECURITY
External signaling relay m P.102
IF-DA Door station m P.30
Power supply PS-1225S PS-1225UL PS-1820S PS-1820UL
IE-8MD
IE-8HD
6-call master
6-call sub master
RY-AC/A External signaling relay m P.101
PS-1225 m P.103 PS-1820 m P.104
Features
Wiring
l Expandable to 6-station system l Selective or All Call between inside stations l Door select and monitor button (on IE-8MD only) l AC or DC power source l Selective door release control l Chime tone cutout on inside stations, selectable
360m / 1.0mma IF-DA
M
IE-8MD
IF-DA
IE-8HD
1
IE-8MD IE-8HD IE-8HD IE-8HD IE-8HD IE-8HD 4
IE-JA 2
M
1 2
3
M
EL-10S
IE-JA
EL-10S
M
4 IE-8HD
5 IE-8HD
H
T
6 IE-8HD
4
D1 E1 D2 E2 EL EL SL SL 1 2 3 4 + –
2 1 2 3 4 station # setting 2
4 5 6
Internal communication by Selective Call or All Call. Chime tone can be muted at each station selectively.
IF-DA 130
210
83.5
83.5
98
Communication
28
IE-JA 115
110
116
83.5
10
79
4
3 1 2 3 4
4 1 2 3 4
5 1 2 3 4
6 1 2 3 4
3
4
5
6
4 5 6
4 5 6
4 5 6
4 5 6
Specifications (IE-8MD) Power supply
IE-8MD IE-8HD
4
H : AC transformer T : PS-1225/S/UL U : PS-1820/S/UL or AC transformer Power source
Unit dimensions
4
1
1 2
IE-8HD
2
190m / 1.0mma
2
Communication network
29
AC-10F Access control keypad, flush mount m P.99
Door release Wiring Distance
12~16V AC, 900mA 12~18V DC, 500mA Intercom only; 12V or 18V DC power supply. AC transformer 12V AC, 10VA or 16V AC, 14VA w/no load voltage 20V or less. Intercom + EL-10S; 12V AC, 10VA only Door calls in w/4- or 2-tone chime and LED, 45 sec. Pick up any handset to reply. Press 1 ~ 6 to call other station with pretone and voice or All Call. Single channel, common talk system. Contact rating: 24V AC/DC, 350mA 2 parallel wires, to door. 4 wires in loop, between rooms. IE-8MD to door 150m(0.65mma) 360m(1.0mma) Rooms 75m(0.65mma) 190m(1.0mma)
Audio Door Stations IE/IF Series Unit dimensions
98
AX-DM 135
IE-DC 130
IF-DA
83.5
28 100
IE-DC
IF-DA
83.5
IE-JA
34
43
IE-FY
220
83.5
128
115 116
10 160
Specifications
Audio door station Mullion type
Wiring Wiring distance
2 parallel wires to master, non-polarized 150m(0.65mma) 230m(0.8mma) 360m(1.0mma)
Flush mount station
IE-FY Door station
66
Features
Used for
l Weather resistant audio door stations l Hands-free communication l Call button rings chime or tone at inside station
IE-1AD(U), IE-1GD(U), IE-2AD(U), IE-8MD, TD-nH/B w/DE-UR (n=3, 6, 12 & 24) TC-M w/TB-AD1 TC-M w/TB-AD10 AX
Some applications
AUDIO ENTRY SECURITY
AX-DM
Door station
22.5
Door station
Door station
IE-JA
160
Surface mount station
l At multiple doors w/TB-ADM10 in place of video door
IE-DL Series Unit dimensions Surface mount station
175
IE-DL1, IE-DL2, IE-DL3
IE-DL1
83.5
1-call surface-mount door station 120
25.5
Specifications IE-DL2 2-call surface-mount door station
Power source Communication Wiring Wiring distance
IE-DL3 3-call surface-mount door station
12~16V AC, 140mA or 12~24V DC, 140mA Press CALL to ring a flat station. Talk hands-free after the inside station replies. 4 to 8 wires, polarized. 150m(0.65mma) 230m(0.8mma) 360m(1.0mma)
Features
Used for
l 1~3-call surface-mount door station with aluminum panel. l Directory back illumination. l AC/DC power source.
IE-1AD(U), IE-1GD(U), IE-2AD(U), IE-2A2D(U), IE-8MD, TD-nH/B w/DE-UR (n=3, 6, 12 & 24)
30
Hands-free Color Video BUS Apartment System The GH system is Hands-free Color video apartment system employing 1pair for Audio & 1pair for video connections. The resident can easily identify visitors by crisp "Color image" together with convenient "Hands-free communication." The GH system configures basically two systems: Standard 48-station, Expanded 500-station systems. Apartment station is selectable out of three types: Color monitor hands-free station (w/optional handset), B&W monitor hands-free station, and hands-free audio station. Entrance station is of a fully modular design with vandal-resistant zinc die-cast panel. The GH system is totally flexible, allowing you to mix-and-match components to create the exact system configuration and features needed for each application.
Capacity Standard
Expanded
48 500
Apartment station
MULTI-UNIT ENTRY SECURITY
• Identify visitors by crisp "COLOR" image • Convenient "Hands-free communication" • Up to 4 apartment stations can be linked per Residence (max. 2 monitor stations) • Monitoring an Entrance camera from Apartment monitor station • Add an external signaling device to Apartment station • Call tone off at individual station with LED indicator • Doorbell at individual door • Auto-Entry (Doctor call) • User-optional feature using SERVICE button, such as turning on/off light, elevator control, etc. • Panic call transfer to security guard station
Color monitor hands-free station
B&W monitor hands-free station
Audio hands-free station
Color monitor hands-free station with optional handset
* The design and specifications are subject to change without notice for improvement.
31
Apartment Station Simple and easy installation • Two single-pair BUS for audio & video • Easily links Entrance station to Apartment station • Resident names & room numbers etc. are programmable by PC
Entrance station Security guard station
Standard
Expanded
5 16
Entrance station
• Vandal-resistant zinc die-cast panel • Sleek & compact semi-flush design • Digital name scrollings - Search resident names and room numbers using keypad - Customer programmable welcome messages - Names & welcome messages are selectable from 5 different languages (English, French, Spanish, German & Dutch)
Standard
Expanded
2
4
Security guard station
• Communicate with all residents and Entrance stations • Receive all Entrance station call-in (Reception mode function) • Absence call-in memory stored with Callback • Receive panic calls from Apartment stations
MULTI-UNIT ENTRY SECURITY
Capacity
Capacity
32
Hands-free Color Video Bus Apartment System System Configuration Standard system 5 Entrance stations 2 Security guard stations 48 Residential stations
Divided cabling with GH-4Z
Monitor to monitor cabling
Trunk line No.1
Trunk line No.6
1Px2 1Px2
On the same trunk line, do not have two wiring methods mixed,
1Px2 1Px2
1Px2
Divided cabling with GH-4Z & Monitor to monitor cabling
1Px2 GH-4Z
1Px2 GH-1KD
GH-1KD
GH-1MD 1Px2
GH-1KD GH-1KD
1Px2
1Px2 1Px2
1Px2 GH-4Z
1Px2 GH-1KD
GH-1KD
GH-1MD 1Px2
GH-1KD
1Px2
1Px2
GH-1KD 1Px2 1Px2
MULTI-UNIT ENTRY SECURITY
1P
1Px2
1Px2 GH-4Z
Doorbell
GH-1KD
Doorbell
GH-1MD 1Px2
GH-1KD + GH-HS
GH-1AD
GH-1KD
GH-1KD
GH-1AD
Apartment No.2~5
300m / 0.8mma
1Px2 150m / 0.8mma
1Px2 1Px2 PS24 1P
1P
GH-BC PS24
1P
Entrance Station : Max. 5
Wiring distance: Entrance station - Bus & Video control unit 300m Video control unit - Farthest Video Apartment station 150m (Expandable with additional Video control unit) Bus control unit - Farthest Audio Apartment station 300m Accumulated total Audio wiring distance 2,500m
33
1P
GH-VBC PS24
1P
1P
PS24 1P
1P
GH-MK GH-MK Security Guard Station : Max. 2
Expanded system 16 Entrance stations, 2 common trunk lines (8 each per common line) 4 Security guard stations, 2 common trunk lines (2 each per common line) 500 Residential stations, 4 sub trunk lines (125 each per sub trunk line) Trunk line
No.1
No.6
No.1
Apartment station Max.125 /SUB line
No.6
Apartment station Max. 125 /SUB line
1Px2
No.2~5
1Px2
GH-BC PS24
1Px2
1Px2
1Px2
1Px2
GH-VBC PS24
1Px2
No.2~5
GH-BC PS24
1Px2
GH-VBC PS24
300m / 0.8mma
1Px2
SUB 1A
SUB 2B COMMON 1
COMMON 1 1Px2
1P
1Px2
1P
1P
1P
1P GH-BCX PS24
GH-BC PS24
1Px2
1P
GH-VBX
1P
GH-BC PS24
COMMON 2 1P
1P PS24
1P
1P
GH-MK GH-MK Security Guard Station Max. 2/COMMON line
Entrance Station Max. 8/COMMON line COMMON 2 1Px2
1P
PS24
PS24
150m / 0.8mma
1P
MULTI-UNIT ENTRY SECURITY
SUB 1B & 2A 1Px2
1P PS24
Entrance Station Max. 8/COMMON line
1P
1P
GH-MK GH-MK Security Guard Station Max. 2/COMMON line
Wiring distance: Entrance station - Expanded Bus & Expanded Video control unit 300m Expanded Video control unit - Farthest Video Apartment station 150m (Expandable with additional Video control unit) Expanded Bus control unit - Farthest Audio Apartment station 300m Accumulated total Audio wiring distance 2,500m/SUB line
34
Hands-free Color Video Bus Apartment System Entrance station Direct-select call button
Digital name scrolling
The directory button panels back-lit display illuminates resident's name or unit number
Color camera
VFD Display
Directory scroll/ Cancel/ Call buttons
Zinc die-cast panel
Keypad illumination Audio module
Access control/ room number dialing keypad
In-use LED
Call button
Directory card & cover
Audio Module
MULTI-UNIT ENTRY SECURITY
GH-DP Audio panel
Digital name scrolling module
GH-DA Audio module
GF-NSP
GH-NS
Display module panel
Digital name scroll display module
Front frame & back box
Camera Module GF-2F 2-module front frame
GF-VP
GH-VA
GF-10KP
Camera panel
Camera module
GH-10K
10-key module panel
10-key module
GF-3F 3-module front frame
Call switch Module
GF-1P
GF-2P
1-call panel
2-call panel
GF-2B 2-module back box
GF-3P 3-call panel
GF-4P
GH-SW
4-call panel
Call switch module
GF-AP
GH-AD
GF-BP
Address panel
Address module
Blank panel
Option
35
GF-3B 3-module back box
Specifications (GH-DA,GH-VA)
System layout example
Wiring Type of cable
Direct-select call button 1P
l Searches of resident names and room number using the keypad l Customer programmable welcome messages can also be shown in 5 different languages (English, French, German, Spanish & Dutch ) l White LED illuminator truns on in low-light conditions
1P
#2
1P
#1
1P
Mounting
H
GH-BC
M
Housing
N
H
Specifications (GH-SW,GH-10K,GH-AD)
M
Lighting Housing
GH-VBC
N
Digital name scrolling 1P 1P 1P #1
1P
Yellow LED Fire-retardant plastic
Specifications (GH-NS)
1P
#2
Two single-pair cable common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia. Box and front frame GF-2B,3B and GF-2F,3F Fire-retardant plastic
Power source
1P 1P
1P
Housing
N
24V DC, supplied by PS-2410LD, LC Fire-retardant plastic
GH-BC
N
GH-VBC
N
Unit dimensions GH-DA
GF-VP
95.2
GH-VA
93
49.5
108 GF-4P
15.8 105.6 GH-NS
88.3
95.2
95.2
14.4
9.9
28.9
38
9
GF-2B
295
16 16
4.5 38 106.2
GF-3B
200
320
225
GF-3F
135
14.4
110
106.2
110 GF-2F
GH-10K
GF-10KP
100.3
GF-NSP
110
44
135 42
85
GF-202HB
110
44
243
GF-202H
243
22 4-call
290
290
65
Audio/Video + Name scroll
225
AIPHONE
320
Hooded surface-mount box
52.3
4.5 38
110
GF-nHB
108
110
88.3
Rain hood
95.2
GF-nH
7.9
51
GH-SW
MULTI-UNIT ENTRY SECURITY
93
7.9
95.2
GH-DP 110
AIPHONE
270 135
16
16
44
44
36
Hands-free Color Video Bus Apartment System Entrance station components Number of calling button
4.
8.
12.
AIPHONE
AIPHONE
16.
AIPHON E
20.
AIPHON E
24.
25.~48.
AIPHONE
AIPHONE
GH-NS, GF-10K
AIPHON E
AIPHON E
GH-VA GF-VP GH-DA GH-DP GH-SW GF-4P GF-2F GF-2B GF-3F GF-3B GF-BP GH-AD GF-AP GH-NS GF-NSP GH-10K GF-10KP
(1) (2) (3) (4) (5)
(6)
(7)
1 1 1 1 1 1 1 1 -
1 1 1 1 2 2 2 2 -
1 1 1 1 3 3 2 2 -
1 1 1 1 4 4 2 2 -
1 1 1 1 5 5 3 3 1
1 1 1 1 6 6 3 3 1
-
-
1
-
1
-
-
-
-
-
-
-
-
1 1 1 1
1 1 1 1 2 2 -
For more than 7 GH-SW, install additional power supply & special device required. Contact local AIPHONE distributor
(1) Camera (2) Audio (3) Call switch (4) 2-module Front frame (5) 3-module Front frame (6) Option (7) Digital name scroll
Interconnecting Modules with Plug-in Conectors
Mounting
. GF-nH W
GF-3B
. GF-nHB 42 W
85
GH-DA GH-DP
GF-3F
(4)
H
H CN3
MULTI-UNIT ENTRY SECURITY
(3) GH-SW
GF-4P
(5)
(2) (1)
CN1
65
22 H
W
GF-102H/HB
243
155
GF-202H/HB
243
290
GF-103H/HB
338
155
GF-203H/HB
338
290
GF-303H/HB
338
425
CN1 CN2
CN2 CN1
CN1 CN2
CN2 CN1
(1) Tamper-proof screw & screwdriver (supplied with GH-BC) (2) Module-mounting bracket (supplied with GF-3F) (3) Internal wiring connector (4) Joint pipe(x2) (5) Cut out openings in advance.
Back box 1.
GH-VA
2.
(1)
(1)
3.
200 mm
295 mm
25mm 25mm 25mm
44mm
W
(2)
W
44mm (2)
1. Two 2-module back boxes 2. Three 3-module back boxes (1) Joint pipe(x2) (2) Do not recess back box more than 15mm.
GF-2B/3B x1 x2 x3 x4 x5 x6 x7 x8 x9
W 110 245 380 515 650 785 920 1055 1190
GH-NS CN3
CN1
CN3 CN1 CN2 GH-DA GH-10K
3. Back box total width (mm)
Adjust camera angle • Changing camera angle
• Viewing from initial camera position 95cm
• Image view area
GH-VA
★
Camera center
GH-VA ★
50cm
65cm
24cm
GH-VA GH-VA 65cm
★
1. Open the rubber cap. 2. Change the camera angle with the lever
113cm
113cm
★
★
★ ★
24cm
*Do not forget to replace the cap. 50cm ★
37
approximate
When adjusted to the left
When adjusted to the right
Residential station Features
GH-1KD
GH-1KDS
(white) (silver) Color monitor apartment station
• Selectable 3 types of stations (Color monitor, B&W monitor, or Audio only) • Hands-free communication, auto-voice actuation • Press-talk operation available • Max. 4 apartment stations can be linked per Residence (max. 2 monitor stations) • Monitoring a Video entrance station (audio & video) • Call tone cutout with LED indicator • Security guard call • Additional handset available for GH-1KD • Option External signaling device to Apartment station (w/GH-RY) Doorbell at individual door with different call tone Auto-Entry (Doctor call), door strikes automatically opens by pressing the Call button at the entrance station. (Not available to use together with entrance light feature) -Panic call, call an Emergency to the Security guard station(s) by panic call button User-optional device can be controlled with SERVICE button, such as -Light on and off at entry way to elevator -Elevator control, goes down to the ground floor or up to resident floor Not available GH-1MD
Functions
Specifications (GH-1KD, GH-1MD, GH-1AD) Buzzer
Apartment station
24V DC, supplied from Bus control units, GH-BC & GH-VBC
Panic alarm
Cal ling &C Do or r om ele mu Mo nic nito ase atio rin n g (a udi o/ vid eo)
B&W monitor apartment station
ory em n larm g m atio ic a callin unic Pan ce mm Co sen Ab ng & li Cal
GH-1MD
O
Video monitor
GH-1KD: 3.5 inch color LCD GH-1MD: 4 inch B&W CRT
Wiring
GH-1KD, GH-1MD: Two Single –pair cables common GH-1AD: Single-pair cable common
Mounting
Wall-mounting only
Housing
Fire-retardant plastic
PANIC CALL switch
Doorbell
Calling & Communication Door release Monitoring (audio) Reception mode function Entrance station Security guard station
Trunk line
Unit dimensions
Audio apartment station Monitor to monitor cabling
Divided cabling with GH-4Z
175
GH-1KD
GH-1AD
1Px2 1Px2
1Px2
125
32
GH-1MD
210
1Px2
MULTI-UNIT ENTRY SECURITY
Power source
External signaling
GH-1KD
GH-1KD
GH-1KD 1Px2
GH-4Z
160
55.5
GH-1AD
Only available to connect on a trunk line with GH-4Z used
GH-HS Option handset for GH-1KD
175
1Px2 GH-1AD
GH-1KD 1Px2 125
32
GH-HS On the same trunk line do not have two wiring methods mixed, Divided cabling with GH-4Z & Monitor to monitor cabling
140
GH-1MD
1Px2
177
1Px2
45
46
38
Hands-free Color Video Bus Apartment System Security guard station Features
Unit dimensions
GH-MK
Security guard station
GFW-S
Desk-top stand
60 83.5
210
l Call to residential station GH-MK l Digital display shows name of resident & room number l Monitoring a Video entrance station (audio) l Receive all Entrance station call-ins (Reception mode function) 215 69 l Absence call-in memory stored with Callback l Option Specifications (GH-MK) Doorbell at door with different call tone User-optional device can be controlled with Power source 24V DC, supplied by PS-2410LD, PS-2410LC SERVICE button, such as Max. 16 letters for names; English, VFD display -light on and off at entry way to elevator French, German, Spanish & Dutch l Receive a Panic call from apartment station Wiring Type of cable
2 single-pair cables 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia.
Mounting
Wall-mounting or Desk-top mounting on GFW-S Fire-retardant plastic
Housing
Control units System layout example
1P(Audio) 1P(Video)
BUS (Audio/Video) MAX.6
Monitor to monitor cabling
Divided cabling with GH-4Z 1
2
3
4
5
6
150m
Expand pos. 1Px2 1Px2
GH-4Z GH-1KD
GH-1KD
GH-1KD
EXP GH-1KD
GH-VBC GH-1KD
GH-BC Bus control unit
STD
max. 2
On a single trunk line, do not have two wiring methods mixed, Monitor to monitor & Divided cabling with GH-4Z
GH-BC
GH-VBC
PS24
PS24
150m
MULTI-UNIT ENTRY SECURITY
GH-1KD
PS24
GH-BC GH-VBC PS24
1Px3
PS24
PS24
EXP
STD
Standard pos.
Wiring distance
GH-VBC Video Bus control unit, expander video control
GH-BC, GH-VBC to Farthest Entrance station GH-BC, GH-VBC to Farthest Video apartment station GH-BC, GH-VBC to Farthest Audio apartment station GH-BC, GH-VBC to each Power supply GH-RY to Entrance station Accumulated Audio lines (R1, R2) Total wiring distance
Distance (Diameter of wires) 300m(0.8mm) 150m(0.8mm) Expandable 150m with additional GH-VBC & Power supply 300m(0.8mm) 5m(0.8mm) 300m(0.8mm) 2,500m(0.8mm)
Type of Cable 2-conductor cables solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia.
Specifications (GH-BC, GH-VBC)
Unit dimensions
Power source
GH-4Z
Consumption Wiring Housing
108.5
Video 4-zone divider
GH-BC, GH-VBC, GH-4Z
122.5
39
24V DC, supplied by PS-2410LD, PS-2410DIN 900mA. Single-pair cable common Fire-retardant plastic
Specifications (GH-4Z) 61
Wiring Mounting Housing
Two Single-pair cables common DIN rail Fire-retardant plastic
Expanded control units Features l Expandable to max. 500 Apartment stations, 16 Entrance stations, and 4 Security guard stations
System layout example
GH-1KD
GH-BCX Expanded Bus control unit
GH-BC
GH-VBC
PS24
PS24
GH-1KD
GH-BC
SUB1B SUB2A 1Px2
SUB1A
PS24
1Px2
GH-VBC PS24
SUB2B
1Px2 COMMON 1 COMMON 1 PS24
PS24
GH-BCX
GH-VBX
PS24
1Px2 COMMON 2 PS24
GH-MK COMMON 2
GH-MK
GH-MK
GH-MK
PS24
GH-BC
GH-BC
PS24
PS24
l COMMON trunk line: Requires one each of GH-BC & Power supply l COMMON trunk line: Max. 8 Entrance stations & 2 Security guard stations l SUB COMMON trunk line: Max. 125 Apartment stations
GH-VBX Expanded video control unit
Specifications (GH-BCX, GH-VBX)
Unit dimensions GH-BCX, GH-VBX
Power source 108
PS-2410LC. GH-VBX: Supplied from GH-BCX Wiring
Single-pair cable common
Mounting
DIN rail
Housing
Fire-retardant plastic
Power supply Unit dimensions
Specifications
PS-2410LD PS-2410LC
Power supply
PS-2410LD
Power source
220-240V AC 120V AC
PS-2410LC
164
Secondary output voltage & current 24V DC, 1A 24V DC, 1A 66
95 RD
BK
RD : Red, BK : Black
PS-2410LD
MULTI-UNIT ENTRY SECURITY
61
210
GH-BCX: 24V DC, supplied by PS-2410LD,
PS-2410LC
Option
GH-RY External signaling relay entrance light, external buzzer
W-DIN11
AC-10S
AC-10F
DIN mounting rail for GH-BC, GH-VBC, GH-4Z
Access control keypad, surface mount m P.99
Access control keypad, flush mount m P.99
40
Hands-free Color Video Bus Apartment System GH Lift control adaptor Features l Lift is controllable from apartment station while communicating with entrance station. When door release button is pressed, electric door strike is activated and simultaneously output signal is transmitted to the lift controller or the access controller. l Selectable dry contact: Normally Open or Normally Closed l System set up data is programmable on your PC * GH-BCX/A & GH-DA/A is required to use GHW-LC.
GHW-LC
Lift control adaptor
Functions
Cabling
1P(Audio) 1P(Video) 1P
GH-1KD
ica
tio
n
GH-1KD
un
eas
e
mm
rel
Co
Distribution point
PS24
PS24
)
Ca
on
cti
Do
or
ea
g&
GH-VBC
(on
llin
GH-BC
ol
ntr
Co
MULTI-UNIT ENTRY SECURITY
1P×2
1P×2 SUB1 GH-BCX/A
SUB1A
GH-VBX
Entrance station Lift
COMMON 1
COMMON 1
PS24
Unit dimensions
GH-BC
GH-BC
GHW-LC Distribution point
Distribution point
PS24
108
PS24
210
61
1P×2
PS24
GHW-LC
Specifications Power source Relay
Wiring Mounting Housing
Supplied by GH-BC Output 20 Contact rating 24V AC/DC, 0.5A N/O or N/C dry contact Operating time From 1 to 600 seconds Single-pair cable DIN rail Fire-retardant plastic
GH-MK
PS24
Entrance station Lift
PS24 :PS-2410LD,
41
PS-2410LC
Lift controller
*Not available in Europe
GH CCTV camera interface adaptor for Reception Features Tenant can receive a call from concierge with visitor’s picture image through CCTV camera. In luxurious condominium, concierge receives all visitors directly instead of using the entrance station. In case concierge asks the tenant to verify the visitors, GH-CCTV allows GH-MK to call apartment station with the image from CCTV transferred. The tenant can communicate with concierge while the picture of visitor displayed at the apartment station. Monitoring the CCTV camera is also available from the apartment station.
GH-CCTV CCTV camera interface adaptor for Reception
Functions
Cabling
1P(Audio) 1P(Video) 1P
CCTV camera
Video CCTV camera Coaxial cable
GH-1KD
Power supply
GH-1KD GH-CCTV
n
g
llin
Ca
tio
a nic
Monitoring only
u
m
m
Co
1P×2
1P×2
GH-BC GH-VBC GH-MK
PS24
PS24
CCTV camera Coaxial cable
Unit dimensions Power supply
GH-CCTV
1P×2
93
Specifications
Mounting
1P×2
GH-CCTV
205 340
Power source Video signal
MULTI-UNIT ENTRY SECURITY
Monitoring (Video)
GH-MK PS24
Supplied by GH-BC & GH-VBC NTSC 1V P-P 75d Desk-top or wall-mounting
Parking lot
PS24 :PS-2410LD,
PS-2410LC
42
Hands-free Color Video Bus Apartment System Cabling 1P(Audio) 1P(Video) 1P
Standard system Capacity 5 Entrance stations 2 Security guard stations 48 Residential stations
Monitor to monitor cabling
Divided cabling with GH-4Z
Trunk line No.2 1Px2
Trunk line No.1
1Px2
Doorbell 1Px2
GH-4Z
1Px2
GH-1KD
1Px2 1Px2
1Px2 1Px2
1Px2
1P
1P
1Px2
GH-4Z
Doorbell
Doorbell
Doorbell
Doorbell GH-1KD
GH-1KD
GH-1KD
GH-1MD
MULTI-UNIT ENTRY SECURITY
GH-1MD, unlike GH-1KD, is only available to connect on a trunk line with GH-4Z used
1Px2
GH-1AD
GH-1AD
GH-1KD
Max. 4 apartment stations can be linked per Residence (including max. 2 monitor stations)
1Px2
On the same trunk line, do not have two wiring methods mixed, Monitor to monitor & Divided cabling with GH-4Z 1Px2 Trunk line No. 3 to 6 1Px2
Distribution point
R1
PS24
R2
PS24
GH-BC
GH-VBC 1Px2
Light control Timer
Entrance No. 2 to 5
GH-RY 1Px2
1P
1P
AC 1P Light
PS24 Door release
Doorbell
PS24 GH-MK
Entrance station
Security guard station
Cable: 1P x 2, 2-conductor cable solid copper & non-braided, polyethylene insulation
43
Wiring Monitor to monitor cabling
Divided cabling with GH-4Z
Trunk line No.2
Trunk line No.1 GH-4Z A B R1 R2 B1 B2
GH-1KD OUT
B1 B2
R1 R2 B1 B2 LINE OUT B1 B2 OUT 3 OUT 4 R1 R2
1Px2
B1 IN B2 OUT IN
R1 R2 R1 R2 C CE
A
B
Terminate the last GH-4Z
A
IN IN
B1 B2 OUT 1 R1 R2
R1 R2 C CE
GH-1MD
R1 OUT R2
R1 OUT R2
R1 IN R2 C CE
R1 IN R2 C CE
GH-1AD
GH-1AD
OUT 2
LINE IN R1 R2 B1 B2
B1 B2 R1 R2
Doorbell 1Px2
R1 OUT R2 R1 IN R2 C CE A
B1 OUT B2
1Px2
B1 B2
R1 OUT R2
B1 IN B2
B
1Px2
B1 IN B2
B1 OUT B2
1Px2
1Px2 B1 B2 R1 R2
GH-4Z Doorbell
B1 OUT B2
Doorbell
Door bell 1Px2
B
R1 IN R2 C CE A
B
GH-1KD B1 OUT B2
GH-1KD
B1 IN B2
B1 IN B2
R1 OUT R2
R1 OUT R2
R1 IN R2 C CE
R1 IN R2 C CE
A
Door bell
B
A
B
GH-1KD
GH-1KD 1Px2
GH-BC R1 R2
Distribution point
MULTI-UNIT ENTRY SECURITY
Trunk line No. 3 to 6 1Px2 Power supply
+ -
+ -
+ -
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 OUT1 OUT2 OUT3 OUT4 OUT5 OUT6 IN1
AC
IN2
IN3
IN4
AC
Power supply
IN5
A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
+ -
EXP
STD
Video Entrance station No. 2 to 5
Light control Timer Orange
Blue 1Px2
GH-MK
1P
Orange GH-RY White Light GH-DA
Doorbell CN2
R1 R2 ELB ELC ELM RY RY CN1
A1 A2 CN3
+
GH-VA GH-NS
CN1
+
+
CN3
-
-
AC AC
-
CN100
R1 R2
R1 R2
R1 R2 C CE + -
R1 R2 C CE + -
Power supply
Power supply GH-10K
2nd GH-MK
SW1
SW1
Entrance station
Apartment station and Security guard station have following options GH-1KD, GH-1MD, GH-1AD l Doorbell l Panic alarm switch l User-optional device*(not available with GH-1MD) l External buzzer*(used w/GH-RY) l Doctor call* Doorbell button *Option connector cable is required. Contact local AIPHONE distributor
locally available
R1 R2 C CE K KE
• • •• • •
Option connector cable User-option device External buzzer Doctor call
GH-MK l Doorbell l User-optional device* l External buzzer* (used w/GH-RY)
R1 R2 C CE
• •• •• •
Option connector cable User-option device External buzzer
Doorbell button Panic Call switch (w/break contact) locally available
*Option connector cable is required. Contact local AIPHONE distributor
44
Two-Wire Bus System ENTRANCE
5
RESIDENCE
100or250 GF Audio Entrance station modules
Entrance station l Direct-select Call Button
l Digital Name Scrolling
l Audio Module
l Direct-Select Keys
GF-DP
GF-1P
GF-2P
Audio panel m P.51
1-call panel m P.51
2-call panel m P.51
GF-DA
GF-3P
GF-4P
Audio module m P.51
3-call panel m P.51
4-call panel m P.51
Audio, Digital keypad, LCD Directory & address panels
Audio, 4-call
Audio, 16-call with address panel
Frame & Box Assemble the following in as many rows as required. GF-2F 2-module Front frame GF-2B 2-module Back box GF-3F 3-module Front frame GF-3B 3-module Back box
GF-SW Call switch module m P.51
PP.52
MULTI-UNIT ENTRY SECURITY
Features
Communication network
l Fully modular Entrance station. Vandal-resistant construction l Two-wire Bus throughout system l One or two apartment stations l Call tone off at individual station with blinking LED indicator l Door release & external light, Bus line-controlled l User options: Doorbell at individual door. Auto-Entry (auto door strike) l User-optional feature using SERVICE button
GF-1DK GF-1DK
GF-1DK
Capacity l 1 or 2 apartment stations within a residence l Entrance station panel : 100-call sized l Direct-select call button : Total 150 apartment stations incl. second stations l Digital name scrolling : Total 250 apartment stations incl. second stations GF-1DK
O
1.
GF-MK 1
A
2
B
C
D
3
E
G
4
H
5
I
J
K
L
M
PQ
8
R
T
U
F
6
N
7S
O
9Z
WX
V
Y
0
1.
M GF-MK
2.
1
A
2
B
C
D
G
4
H
J
L
M
PQ
V
O
9Z
WX
T
U
F
6
N
8
R
3
E
5
I
K
7S
Y
0
2. 5.
J Calling & Communication K PANIC CALL sounding & Answer-back. GF-MK; Concierge station must be used w/GF-1DK. I Doorbell O PANIC CALL switch used for GF-1DK only Bus line-controlled; M Door Release L External light
45
l Digital Name Scrolling
Apartment station
Concierge station
Bus control unit
Lineup
GF-NSP LCD directory panel m P.51
GF-BC Bus control unit m P.54
GF-NS LCD directory m P.51
Power supply
GF-MK
GF-1D
GF-10KP
GF-nHB
Rain hood m P.52
Hooded surfacemount box m P.52
GF-AP
GF-AD
Address panel m P.51
Address module m P.51
GF-BP
GFW-S
Blank panel m P.51
Concierge station m P.53
Apartment station m P.53
Digital keypad panel m P.51
GF-nH
Desk-top stand for GF-MK m P.53
GF-1DK Concierge call apartment station w/Panic call transfer Use with GF-MK m P.53
GF-10K Digital keypad m P.51
GFW-LD
PS-2410LD
m P.54
m P.54
Wiring 2.BUS
2.BUS
1P
1P GF-1DK
GF-1DK
GF-1DK x 2
1P
1P
1P
R1 R2
GF-1DK
1P
1P
GF-1DK 1P
1P
GF-1DK
R1 x 2 R2
GF-1DK
1P
1P
1P
R1 R2
1P
1P
C CE
C CE
R1 R2
R1 GF-1DK R2
1P
1P
C CE
C CE
O
K KE
1P 1.BUS
1.BUS
3.BUS
C CE
O
MULTI-UNIT ENTRY SECURITY
Cabling
Long distance adaptor m P.55
PS-2410LC
GF-BC
1P
1P (NP)
1P (NP)
1P (NP)
R1, R2 1P
1P 1P
R1 R2
1P
R1 R2
1P
R1 + R2 –
1P
R1 R1 R2 R2 1
M
PQ
L
PQ
V
O
9Z
WX
T
WX
T
U
F
6
N
8
R
3
E
J
M
G
J
l Bus line: Any number per system. Max. 50 stations per line. 1P, Non-polarized
D
G
GF-MK
C
5
I
K
7S
Y
0
GF-MK
L
H
ML
H
B2C
K5L
E3F
N6O
Y9Z
WX
B
4
H
O
Y
U8V
T
2
F
6
9Z
PQ
1
3
A
D
L
N
V
0
2.GF-MK
M
C
E
K
U
0
R7S
J
A
2
B
5
I
8
R
H4I
G
1P 1 4
H
7S
EL EL + b
A
EL EL + b
1P
N
D
GF-BC
N
1P
1P
1.GF-MK
M
l Bus line (MAX.) 50 stations per Line l K, KE terminals; Mounted on GF-1DK only l For controlling light at the entrance, use Aiphone's MAW-B, which provides dry closure contact.
N : PS-2410LD, PS-2410LC
46
Four-Wire Common Video System ENTRANCE
5
RESIDENCE
100or250 GF Audio/Video Entrance station modules
Entrance station l Direct-select Call Button
l Digital Name Scrolling
l Camera Module
l Audio Module
l Direct-Select Keys
GF-VP
GF-DP
GF-1P
GF-2P
Camera panel m P.51
Audio panel m P.51
1-call panel m P.51
2-call panel m P.51
GF-VA
GF-DA
GF-3P
GF-4P
Camera module m P.51
Audio module m P.51
3-call panel m P.51
4-call panel m P.51
l Audio Module Audio, Camera & Digital Keypad & LCD Directory
Audio, Camera & Direct-select 12-call buttons
Frame & Box Assemble the following in as many rows as required. GF-2F 2-module Front frame GF-2B 2-module Back box GF-3F 3-module Front frame GF-3B 3-module Back box
GF-SW Call switch module m P.51
PP.52
MULTI-UNIT ENTRY SECURITY
Features
Communication network
l Fully modular Entrance station. Vandal-resistant construction l Two single-pair cables run throughout system l Second monitor or audio station can be installed l Call tone off at individual station with blinking LED indicator l Door release & external light, Bus line-controlled l Optional functions: Doorbell at individual door. Auto-Entry (auto door strike) l User-optional feature, using SERVICE button
GF-1MDK x 2
GF-1MDK
Capacity l 1 or 2 apartment stations within a residence l Entrance station panel : 100-call sized l Direct-select call button : Total 150 apartment stations incl. second stations l Digital name scrolling : Total 250 apartment stations incl. second stations
GF-1MDK
O 1.
M 1
A
2
B
C
D
G
5
I
J
K
L
M
PQ
O
9Z
V
WX
T
U
F
6
N
8
R
3
E
4
H
7S
Y
0
2.
GF-MK
5. 1
A
2
B
C
D
G
5
I
J
K
L
M
PQ
V
O
9Z
WX
T
U
F
6
N
8
R
3
E
4
H
7S
Y
0
GF-MK
J Callig & communication K PANIC CALL sounding & Answer-back. GF-MK; Concierge station must be used w/GF-1MDK.
I Doorbell O Panic call switch, available with GF-1MDK only Bus line-controlled; M Door Release L Light
47
Apartment station
l Digital Name Scrolling
Concierge station
Bus control unit
Lineup
GF-BC Bus control unit m P.54
GF-NSP LCD directory panel m P.51
GF-NS LCD directory m P.51
Video control unit m P.54
4-apt. Bus junction unit m P.54
Concierge station m P.53
GF-1MDK
GF-AP
GF-AD
Address panel m P.51
Address module m P.51
GFW-S
GF-BP
Desk-top stand for GF-MK m P.53
Concierge call apartment monitor station w/Panic call transfer Use with GF-MK m P.53
GF-10K
Hooded surfacemount box m P.52
GF-MK
Apartment station m P.53
Digital keypad panel m P.51
GF-4Z
GF-nHB
Rain hood m P.52
Power supply
GF-1MD GF-10KP
GF-VBC
GF-nH
PS-2410LD
Digital keypad m P.51
PS-2410LC m P.54
m P.54
Wiring 1.BUS
2.BUS GF-1MDK
1P x 2
SW1
A
GF-1MDK (x 2)
OUT B
IN
B1 B2 B1 B2
R1 R2 R1 R2
OUT IN
C CE
K KE
O GF-1MDK
1P x 2 2
OUT
SW1
O
B
A
IN
2 SW1
GF-1MDK
1P x 2
OUT
B
A
IN
B1 B2 B1 B2
R1 R2 R1 R2
B1 B2 B1 B2
R1 R2 R1 R2
OUT IN
C CE
K KE
O OUT IN
C CE
K KE
O
GF-1MDK 2
OUT
SW1
GF-1MDK
B
A
IN
R1 R2 R1 R2
B1 B2 B1 B2
OUT IN
C CE
K KE
O
1P x 2 GF-1MDK
VIDEO
MULTI-UNIT ENTRY SECURITY
Cabling
Blank panel m P.51
AUDIO
1.BUS 2
GF-VBC
1. ~ 6. BUS(Video)
6
1P x 2 VIDEO
1P x max.6 VIDEO
AUDIO
AUDIO
(1) 1P
1P 1
A
2
B
G
J
L
1P
1
C
5
I
K
L
M
PQ
8
R
V
O
9Z
WX
T
U
F
6
N
7S
3
E
4
H
J
WX
T
Y
2
B
O
9Z
G
PQ
V
0
D
M
U
F
6
N
8
R
A
5
I
K
7S
3
E
4
H
Y
+ B1B2 B1B2 B1B2 B1B2 B1B2 B1B2 – OUT6 OUT5 OUT4 OUT3 OUT2 OUT1
N
+ –
GF-VBC IN4
IN3
IN2
R1, R2
IN1
N 2.GF-MK
R1 R1 R2 R2 GF-MK
A1A2 A1A2 A1A2 A1A2 A1A2
1
2
B
4
H
C
K
L
PQ
8
R
V
O
9Z
WX
T
U
F
6
N
7S
3
E
5
I
M
N
N
IN5
R1 + R2 – GF-BC
1
J
N + N
0
2
G
GF-BC
3
D
GF-VBC
4
A
1P x 2
C
D
1P x 2
5
Y
0
GF-MK
GF-MK A1A2
R1 R2 GF-DA
Audio/Video trunk lines l There are methods of installing audio/video trunk lines, i.e. Monitorto-Monitor or homerun to GF-4Z’s. The two methods may be used within a system. But do not mix two methods on a same trunk line. l BUS (Audio/Video) Line; Up to 6 lines. Two single-pair cables common. Max. 25 Monitors per Line.
A1A2
R1 R2 GF-DA
(1) Required when the second GF-1MDK is installed within an apartment. l K, KE terminals for Panic call switch; GF-1MDK only. l For controlling light at the entrance, use Aiphone's MAW-B, which provides dry closure contact. N : PS-2410LD, PS-2410LC
48
Two-Wire Bus System ENTRANCE
8
RESIDENCE
4,800 GF Multi-Tower Multi-Tower System
GF-GD-TS Central entrance station (Audio only)
GF-GMK Central security guard station
VGX-D-YBOX Built-in back box
GF-6GX24-2 Central control unit
Power supply PS-2410LD (GF) m P.54 PS-1215DIN (Central)
MULTI-UNIT ENTRY SECURITY
Features
Communication network
l Max. 24-Tower, 4,800-Residence System l Two-pair cable throughout GF standard Single-tower system l Panic call annunciation to Central & Single-tower security guard stations l Audio only Central entrance stations with two talk channels
C
GF
GF-1MDK
AIPHONE
GF-MK
A GF-GD-TS
Capacity Multi-tower No. of Towers Central security guard station Central entrance station (audio) Residential monitor station Single-tower Security guard station Entrance station (audio/video) Resodential monitor station
49
24 bldgs. 4 pcs 8 pcs 4,800 pcs 1 pce 4 pcs 250 pcs
B GF-GMK
(A) COMMON ENTRANCE (B) SECURITY GUARD (C) Single-tower RESIDENTIAL MONITOR Doorbell PANIC CALL P Callig & Answering J Callig & communication (both ways) X Door strike Y Panic call
*Not available in Europe, Australia, nor New Zealand
Single-Tower System
GF Entrance station w/Digital name scrolling m P.51
GF-MK
GF-1MDK
GF-1DK
Concierge call apartment monitor station (w/Panic call transfer) m P.53
Apartment station (concierge call) w/Panic call transfer m P.53
Concierge station m P.53
GF-GTX Single-tower control unit
Unit dimensions
GF-GD-TS
GF-GTX 5P
GF-GTX 5P
GF-GTX 5P
GF-GTX 5P
460
C
1Km
350
A GF-GD-TS 3P
GF-6GX24-2
2.5Km
PS PS
GF-GD-TS 3P
PS
PS
PS
300
GF-GMK GF-GTX
3P
PS
PS
GF-GD-TS 3P
5P
GF-GTX 5P
PS
GF-GTX 5P
PS
PS
PS
GF-GMK
PS
20 80
98
340
GF-GTX 5P
GF-GMK
(1)
(2)
107
106
GF-GTX
3P GF-GTX 5P
GF-GTX 5P
GF-GTX 5P
GF-6GX24-2 3Px 8
PS
PS
PS
PS
1
2
4
5
7
8
9
0
C
320
GF-GTX 5P
230
PS
MAX. 300m
3 6
MULTI-UNIT ENTRY SECURITY
Wiring
3Px 4 PS
GF-GD-TS 3P
MAX. 300m
PS
GF-GTX 5P
GF-GTX 5P
PS
PS
PS
GF-GTX
PS
GF-GMK
PS
GF-GD-TS 3P
GF-GTX
250
5P
230
80
3P
GF-GD-TS 3P
GF-GD-TS 3P
GF-GTX 5P
GF-GMK
5P
PS
GF-GTX 5P
PS
GF-GTX 5P
GF-GTX
GF-GMK (1) Desktop (2) Wall mounting
5P
3P
1Km
PS
PS
B
PS
GF-GTX 5P
PS
GF-GTX 5P
PS
GF-GTX 5P
GF-GTX 5P
PS PS
PS
PS
PS
1Km
Multi-tower trunk line (A) Common entrance 300m/unit (farthest). 1Km(cumulative All stations) (B) Central security guard 300m/unit (farthest). 1Km(cumulative All stations) (C) Tower interface adaptor 1km/unit (farthest). 2.5Km(cumulative All units) C : PS-1215DIN
Specifications (GF Multi-tower) Power source & consumption GF-GGX24-2: 12V DC, 24W (Standby 16W) GF-GD-TS: 12V DC, 200mA (100mA) GF-GMK: 12V DC, 350mA (120mA) GF-GTX: 12V DC, 2.0W (1.5W) PS-1215DIN Power supply Communication Electric tone, Central entrance to Residence Twisted pairs CPEV, 0.9mm dia. Cable 5 twisted pairs, CPEV0.9mm, CCU ~ GF-GTXs Wiring 3 twisted pairs, CPEV0.9mm, CCU ~ GF-GMKs 3 twisted pairs, CPEV0.9mm, CCU ~ GF-GD-TS Distance 300m/0.9mm, CCU ~ GF-GD-TS (8 pcs total 1Km) 300m/0.9mm, CCU ~ GF-GMK (4 pcs total 1Km) 1Km/0.9mm, CCU ~ GF-GTX (4 bldg. total 2.5Km per block)
50
Two-Wire Bus System Entrance station modules & panels System layout example
Audio Module
. AUDIO
#2
Specifications (GF-DA) #1
1P
1P
AIPHONE
GF-DP
GF-DA
Audio panel
Audio module
Call switch Module
Consumption Entrance station Wiring Type of cable
1P
AIPHONE
H
H
M
AUDIO
M
GF-BC
N
Mounting Housing Weight
. AUDIO & VIDEO #2
30mA 5 Single-pair cable common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia. Box and front frame GF-2B,3B and GF-2F,3F Fire-retardant Plastic Approx. 180g
#1 1P 1P
Specifications (GF-SW)
1P
Capacity Lighting Housing Weight
1P
GF-1P
GF-2P
1-call panel
2-call panel AIPHONE
AIPHONE
H
H
M GF-3P
GF-4P
3-call panel
4-call panel
GF-VBC
GF-BC
N
N
M
#2
#1
1P
1P
GF-SW
Specifications (GF-VA) Consumption Entrance station Wiring Type of cable
. AUDIO & VIDEO + GF-NS
1P
1P
Call switch module
N
Specifications (GF-NS) Power source
Unit dimensions GF-VP
GF-VA
Camera panel
Camera module
. GF-DP
(1)
Consumption Wiring Type of cable
7.9
110
AIPHONE
Digital name scrolling module
225
135 (2)
GF-NSP
GF-NS
Housing Weight
320
Housing
Fire-retardant Plastic
Lighting
Yellow LED
Weight
Approx. 90g
44
GF-10K
Digital keypad panel Digital keypad
44
Specifications (GF-10K)
16
135
GF-10KP
16
Specifications (GF-AD)
(3)
Yellow LED
Weight
Approx. 90g
E
O
N
P
9
Z
I
L
J
G
T
U
Fire-retardant Plastic
Lighting 6
K
8
W
5
M
S
C
A
H
7
3 D
4 Q R
AIPHONE
B
Housing
F
2
V
1
225
Lineup
X Y
0
270
GF-AP
GF-AD
GF-BP
Address panel Address module Blank panel
24V DC, supplied by a power supply PS-2410LD, LC 0.07A Two single-pair cables common. 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia. Fire-retardant Plastic Approx. 150g
AIPHONE
LCD directory panel LCD directory
51
140mA 5 Two single-pair cables common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia. Fire-retardant Plastic Approx. 140g
N : PS-2410LD, PS-2410LC
95.2
MULTI-UNIT ENTRY SECURITY
Housing Weight
Camera Module
100-call buttons Yellow LED Fire-retardant Plastic Approx. 90g
16
44
(1) Audio, 4-call (2) Audio, 8-call (3) Audio/Video + Name scroll
Entrance station mounting accessories Mounting
Front frame & back box
. GF-nH GF-3B
42
W
GF-DA
. GF-nHB W
GF-DP
GF-3F
(4) H
H 65
22
(3)
GF-3F
GF-2B
GF-3B
2-module front frame
3-module front frame
2-module back box
3-module back box
(5)
GF-SW
GF-4P
GF-2F
85
(2) (1)
H
W
GF-102H/HB
243
155
GF-202H/HB
243
290
GF-103H/HB
338
155
GF-203H/HB
338
290
GF-303H/HB
338
425
(1) Tamper-proof screw & screwdriver (supplied with GF-BC) (2) Module-mounting bracket (supplied with GF-3F) (3) Internal wiring connector (4) Joint pipe(x2) (5) Cut out openings in advance.
Back box 1.
Hooded surfacemount box
Rain hood
3.
200 mm
GF-nHB
GF-nH
(1)
2.
(1)
295 mm
25mm 25mm 25mm
44mm
W
(2)
44mm (2)
W
1. Two 2-module back boxes 2. Three 3-module back boxes (1) Joint pipe(x2) (2) Do not recess back box more than 15mm.
GF-2B/3B x1 x2 x3 x4 x5 x6 x7 x8 x9
W 110 245 380 515 650 785 920 1055 1190
3. Back box total width (mm)
AUDIO
(1) 4.
8.
AIPHONE
AUDIO / VIDEO
AIPHONE
(1) 4.
(2) (3)
(4)
(5) (6)
(7)
(8)
GF-VA GF-VP GF-DA GF-DP GF-SW GF-4P GF-2P GF-2F GF-2B GF-3F GF-3B GF-BP GF-AD GF-AP GF-NS GF-NSP GF-10K GF-10KP
16.
AIPHONE
8.
AIPHONE
(1)
12. AIPHONE
12.
AIPHONE
20. AIPHONE
16.
AIPHONE
30. AIPHONE
AIPHONE
20.
AIPHONE
AIPHONE
30.
AIPHONE
GF-NS GF-10K
40.
GF-NS GF-10K
40.
AIPHONE
AIPHONE
AIPHONE
4. 1 1 1 1 1 1 -
4. 1 1 1 1 1 1 1 1
8. 1 1 2 2 1 1
8. 1 1 1 1 2 2 2 2 -
12. 1 1 3 3 2 -
12. 1 1 1 1 3 3 2 2
16. 1 1 4 4 2 2
16. 1 1 1 1 4 4 2 2
20. 1 1 5 5 2 2
20. 1 1 1 1 5 5 3 3
30. 1 1 8 7 1 3 3
30. 1 1 1 1 8 7 1 4 4
40. 1 1 10 10 4 4
40. 1 1 1 1 10 10 4 4
GF-NS, GF-10K 1 1 1 1
GF-NS, GF-10K 1 1 1 1 2 2 -
-
-
-
-
-
-
1
-
-
1
-
1
1
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1 1 1 1
1 1 1 1
MULTI-UNIT ENTRY SECURITY
Entrance station components
(1) Number of calling button (2) Camera (3) Audio (4) Call switch (5) 2-module Front frame (6) 3-module Front frame (7) Option (8) Digital name scroll
52
Two-Wire Bus System Residential station Residential audio station
GF-1D Apartment station
Features
Specifications (GF-1D, GF-1DK)
Auto-Entry (Auto door strike) Setting required. Call tone from Entrance and Doorbell are differentiated.
Power source
24V DC, supplied from 2-wire Bus control unit GF-BC
Consumption Total station Wiring
16mA 250 residential stations Single-pair cable common
Trunk line GF-1DK
AUDIO
Concierge call apartment station w/Panic call transfer (Photo)
Type of cable
GF-1D
GF-1D 1P
1P
1P
GF-BC
N
AUDIO & VIDEO
AUDIO & VIDEO
1P x 2
GF-1MDK GF-1MDK
GF-1MDK
Residential monitor station
1P x 2
1P x 2
Fire-retardant plastic Approx. 370g
Specifications (GF-1MD, GF-1MDK) Power source
M
GF-1MDK
M
Apartment station
24V DC, supplied from Bus control unit, GF-BC & GF-VBC
M
Consumption
356mA
M
Total monitor station150 GF-1MD(K)’s.
1P x 2
1P x 2
GF-1MDK
1P x 2
GF-1MDK GF-1MDK
1P x 2
250 GF-1MD(K)’s w/GFW-VBC,
M
Expander video control units. 1P x 2
l BUS line (audio); Max. 50 stations l Video line; Max.25 Monitors either via max. 6xGF-4Z’s or Monitor to Monitor. Do not mix two wiring methods on a same trunk line.
Video monitor
4 inch direct view flat CRT
Wiring
Two Single-pair cables common
Type of cable
2-conductor cable solid copper & non-braided, polyethylene
Unit dimensions
insulation, 0.65mm dia.~1.0mm
GF-1DK, GF-1D
GF-1MDK, GF-1MD
dia. Mounting
89
60 83.5
60 83.5
210
GF-1MD
200
MULTI-UNIT ENTRY SECURITY
DOORBELL BUTTON (option)
Housing Weight
1P x 2
GF-1MD
Concierge call apartment monitor station (w/Panic call transfer) (Photo)
dia. Wall-mounting only 60mm or 83.5mm guided
M
1P
GF-4Z
GF-1MDK
Mounting Electrical box
1P
DOORBELL BUTTON (option)
M
2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm
216
63
Wall-mounting only
Electrical box
60mm or 83.5mm guided
Housing
Fire-retardant plastic
Weight
Approx. 1200g
69
Concierge station For either audio or audio/video system
Trunk line
Specifications (GF-MK) GF-1DK GF-1DK 1P 1P 1P
1P
O
O
Consumption LCD display Wiring Type of cable
50mA Max. 16 letters for names Two Single-pair cables common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia.~1.0mm dia. Wall-mounting or Desk-top mounting on GFW-S 60mm or 83.5mm guided Fire-retardant plastic Approx. 900g
1P GF-1DK 1P
O
Mounting
1P
O
1P
H I
3
B C
5 J
N O
7
K L
Z
W
U V
E F
6
8 T
Q R
X Y
M
W
N O
9
X Y
0
GF-MK
GF-MK
N
l Must be used with GF-1DK or GF-1MDK in Concierge station application.
53
60 83.5
0
210
T
9
P
4
6
G
P
S
2
E F
D
K L
8
U V
1
3
B C
5
M
7
Q R
A
H I
J
O Panic call switch
4 G
Desk-top stand
GF-BC
2
D
1P
GF-MK 1
A
1P
Unit dimensions
1P S
Concierge station
Z
GF-MK
GFW-S
Electrical box Housing Weight
GF-1DK 1P
1P
215
69
Bus & Video control units System layout example AUDIO
Specifications (GF-BC)
MAX.50
GF-1DK 1P 1P
Power source
MAX.50 1P GF-1DK
GF-1DKGF-1DK 1P 1P
1P
Mounting Weight
MAX.50 1P 1P
1P
BUS(AUDIO)
Specifications (GF-VBC)
1P 1P
1P 1
2
B
A
3
E
4
G
H
C
D
5
I
K
J
N
7S
PQ
8
R
O
1
Y
2
4 G
0
H I
P
6
8
W
T
U V
E F
N O
Power source
24V DC, supplied by a power supply PS-2410LD, LC 1,100mA. Single-pair cable common. DIN rail Approx. 260g
9
X Y
Z
S
K L
M
7
Q R
3
5 J
Bus control unit
B C
D
9Z
WX
V
A
T
U
F
6
L
M
GF-BC
1P
1P
Consumption Wiring Type of cable
GF-1DK 1P
GF-1DK
1P
24V DC, supplied by a power supply PS-2410LD, LC 900mA. Single-pair cable common. 2-conductor cables solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia. DIN rail Approx. 450g
0
GF-MK & GFW-S GF-MK #4
#5
#3
GF-BC 1P
N
1P
H #2
M
Consumption Wiring Mounting Weight
Specifications (GF-4Z) Wiring Type of cable
#1
Two single-pair cables common. 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm ~ 1.0mm dia. Approx. 450g
AUDIO / VIDEO + GF-NS GF-1MDK
GF-1MDK 1P x 2
M
GF-4Z
1P x 2
Weight
M
Wiring distance GF-VBC Video control unit
1P x 2
1P x 2
M
1P x 2
GF-1MDK
GF-1MDK BUS(Audio / Video) MAX.6 3
2
5
4
6
1P x 2 GF-BC 1P GF-VBC 1P
1P 1Px2
1P 1Px2 1Px2
N N 1P
1Px2
1P
1P
N
1P 1Px2(*)
N
(10)
GF-4Z 4-apt. Bus junction unit
AUDIO system l Max. 250 Apartment stations l Max. 5 Entrance stations l MAX 100-call panel l Max. 3 Entrance stations per BUS line Audio/video system l Max. 250 Apartment monitor stations l Max. 5 Entrance camera stations l Power supply for five GF-NS’s 1Px2(*) : 1P for Audio & 1P for power supply of GF-NS’s M Optional door strike at each entrance
Unit dimensions GF-BC, GF-VBC, GF-4Z
MULTI-UNIT ENTRY SECURITY
1
Distance (Diameter of wires) GF-BC to Distribution point 5m (0.8mm) Distrib. point to Entrance station 300m (0.8mm) Distrib. point to GF-1K(farthest) 300m (0.8mm) GF-VBC to farthest GF-1MDK 1 per resid. line 100m (0.8mm), 150m (1.0mm) GF-VBC to farthest GF-1MDK 2 per resid. line 50m (0.65mm), 100m (0.8mm), 150m (1.0mm) GF-VBC to Entrance station(GF-VA, Video) 100m (0.8mm), 150m (1.0mm) GF-BC, VBC/A to ea. Power supply 5m (0.8mm) GF-NS/A to Power supply 300m (0.8mm), 300m (1.0mm) MAW-B to Entrance station 300m (0.8mm) Total wiring distance(R1, R2) 2.5km (0.8mm)
108.5
M
122.5
61
Power supply Unit dimensions
Specifications
PS-2410LD PS-2410LC
Power supply
PS-2410LD
PS-2410LC
Power source
220-240V AC
120V AC
164
Secondary output voltage & current
RD
PS-2410LC
24V DC, 1A
66
95
PS-2410LD
24V DC, 1A
BK
RD: Red, BK: Black
54
Two-Wire Bus System Long distance adaptor(Audio) Wiring Sub-Bus No.1 Sub-Bus No.2 Sub-Bus Accumulated total wiring Apartment station distance 2500m max.100/Sub-Bus Farthest Apartment 1P total 250/system 1P station max.150m GF-BC
Sub-Bus No.9
1P
GF-BC
N
GFW-LD
GFW-LD
Sub-Bus No.10
1P
GF-BC
GFW-LD
N
GFW-LD
1P
1P
GF-BC
N
1P
Long distance adaptor for audio
1P 1P
Common Bus Accumulated total wiring distance 2000m
Wiring distance GF-DA-Apartment station GF-MK-Apartment station max. 600m
N
GFW-LD
1P
1P
1P 1P 1P
1P
1P
GF-MK
GF-MK
GF-BC
1
3
E
2
B
F
5
I
K
L
M
M
PQ
PQ
V
F
O
9Z
WX
T
U
WX
T
8
R
Y
3
6
N
7S
O
9Z
C
E
4
H
6
J
J
L
N
V
G
G
K
U
D
D
Max.5
C
5
I
8
R
A
A
N N
1
2
B
4
H
7S
Y
0
0
Max.2
*Communication method : Auto-voice actuation
Expanded video control unit Unit dimensions
Wiring
GFW-VBC
5
GF-VBC
+
GF-1MDK
5
6
1
AUDIO BUS
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
Consumption Wiring
R1,R2
OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 IN5 IN4 IN3 IN2 IN1 A1 A2 A1 A2 A1 A2 A1 A2 A1 A2
Type of cable R1 R2 + –
N GF-BC
61
Specifications Power source
VIDEO BUS 4 3 2
N + –
–
122.5
B1 B2
+ –
N
24V DC, supplied by a power supply PS-2410LD, LC 0.9A. Two single-pair cables common 2-conductor cable solid copper & non-braided, polyethylene insulation, 0.65mm dia~1.0mm dia.
Standard & Expanded video wiring (w/GFW-VBC) (1) Required when a second GF-1MD is installed in an apartment(s).
System layout example 6~11
1.
1~5
6~11
2.
1Px2 1Px2 1Px2 1Px2 1Px2 1Px2
GFW-VBC
1~5
IN
1P
150m
150m
150m
MULTI-UNIT ENTRY SECURITY
Expander video control unit
GF-4Z 1P x 2 1
OUT6 OUT5 OUT4 OUT3 OUT2 OUT1 IN1
N GFW-VBC
GFW-VBC, GFW-LD
MAX.6 x GF-4Z's GF-1MDK
B1 B2 B1 B2 B1 B2 B1 B2 B1 B2 B1 B2
+ –
(1)
VIDEO BUS 2 3 4
108.5
6
1P
N 1P
150m
1Px2 1Px2 1Px2 1Px2 1Px2 1P
GF-VBC
AUDIO GF-BC 1P
VIDEO BUS 2
N
1P
AUDIO BUS
1. Increase wiring distance to the farthest monitor stations 1~5 Standard Bus lines 6~11 Expanded Bus lines
N
2
GF-BC
IN
VIDEO 2
N
1P
GF-VBC
GFW-VBC 1P
N
VIDEO 1
150m 2. Increase Video trunk lines
Option
MAW-B Auxiliary light control relay for entrance light
55
W-DIN11 DIN mounting rail for GF-BC, GF-VBC, GF-4Z, GFW-VBC GFW-LD
N
AUDIO
AC-10S
AC-10F
Access control keypad, surface mount m P.99
Access control keypad, flush mount m P.99
Two-Wire Electric Lock Door Phone ENTRANCE
RESIDENCE
4 DA-4DS
1
Entrance station
Lineup
Residential station
EL-10S
AC-10S
Electric door strike m P.101
DA-2DS
DA-4DS
2-call door station
4-call door station
Access control keypad, surface mount m P.99
DAR-1
Call extension
AC-10F Access control keypad, flush mount m P.99
DA-1MD Master station
DAW-P
Power supply PT-1211D PT-1211C
DA-2DG
DA-4DG
2-call door station
4-call door station
m P.103
Wiring
l Two-wire system l Door release wired to door station, requiring no power transformer l User-optional function button l Call tone MUTE with indicator l Call extension sounder
310m / 1.0mma 155m / 1.0mma DA-4DS DA-4DG
M
DA-1MD 2
2
DA-1MD 2
P
P
DA-1MD 2
2 P
P
DA-1MD 2 DAR-1 2 AC15 (1)
Communication network DA-1MD
DA-1MD
DA-1MD
DA-1MD
EL-10S
M Electronic tone. Direct select ring.
~ ~ D E
L L
(2)
DA-4DS, DA-4DG
1 D E 2 D E 3 D E 4 D E
P
~ ~
AC15
~ ~
AC15
~ ~
AC15
PT-1211D/C D E
P
P
D E D E
P
S SE
Unit dimensions DA-2DS,G DA-4DS,G
(3) 22
DA-1MD
61
175
DA-1MD
DA-1MD
DAR-1
(1)
DA-1MD
DA-4DS, DA-4DG 2x2
200
100
SW SW
DA-1MD 89
NP
MULTI-UNIT ENTRY SECURITY
Features
Door station mounting plate (83.5mm)
2x2
2x2
2x2
PT-1211D/C
(1) Ext. device Relay/Controller : User-optional function(AC18V, 40mA) (2) Door release : EL-10S or 16V AC, 20 d or more (3) When a single common power supply is used
Specifications (DA-4DS, G) Power source Power supply Communication Wiring Distance
15V AC PT-1211D, PT-1211C Press and hold down Button to call. 2 wires, throughout system: PS - Master - Door - Door rlse. PT-1211D/DR ~ Door rlse. 110m(0.6mma) 200m(0.8mma) 310m(1.0mma) PT-1211D/DR ~ DA-1MD 55m(0.6mma) 100m(0.8mma) 155m(1.0mma)
56
Audio Entry Security ENTRANCE
RESIDENCE
58 VC-M
1
Entrance station
Residential station
VC-0M
VC-4M
VC-6M
VC-10M
Blank entrance station
4-call entrance station
6-call entrance station
10-call entrance station
Power supply PS-1225S PS-1225UL PS-1225
VCH-8
VCH-16
8-call add-on panel
16-call add-on panel
RY-PA
Electric door strike m P.101
Door release relay m P.101
Apartment station
Other Panels VC-1M,VC-2M&VC-8M
m P.103
MULTI-UNIT ENTRY SECURITY
Features
VC-K
EL-10S
Wiring
l Single entry 0 to 10-call panel l Add-on 8 or 16 call panel(s) l VC-K handset, one or two per residence l Directory back illumination l Single or larger panels up to 58 buttons
800m / 1.0mma
VC-6M
VC-K
VC-K
7
4+1x3
VC-K
M
H
Q
5
VC-K
7 (1)
VC-K
6
VC-K
6
5
4+1x6 2
T VC-6M
VC-K
VC-K
VC-K
1 2 3 4
1 2 3 4
1 2 3 4
B B B
Communication network VC-6M
VC-K #1
M EL-10S
YL
BK
1 2 3 4
1 2 3 4
+ + + + + +
B
+ ---
1 2 3 4 B
B
T
L+ L---
#6
H Direct select ring
57
1 2 3 4
(1) 4 common + 6 (no. of apartments) * Terminal 4 for door release T : PS-1225/S/UL H : AC transformer Q : RY-PA relay BK: Black(2) YL: Yellow(2)
Entrance call panel
Lineup VC-BBX Surface mount box
AC-10S Access control keypad, surface mount m P.99
VC-26MY 26-call entrance station
AC-10F VC-26MT
VC-58MT
26-call entrance station
58-call entrance station
Access control keypad, flush mount m P.99
VC-42MY 42-call entrance station
Unit dimensions (1) VC-K 2
VC-K
VC-K
(2) VC-K
VC-K
VC-M
(2) (1)
60
156
83.5
VC-K 1
210
VC-4M
230
Bz
1 2 3 4 B
1 2 3 4 + +
1 2 3 4
1 2 3 4
1 2 3 4
YL 68
Q BK
B
+
80
61
T
B
+
+ -
1 2 3 4 B
VC-M, VCH VC-26MY VC-42MY VC-26MT VC-58MT VC-BBX
B
T
Added variations (1) Two VC-K stations per apartment. Calling is not available between room stations 1 & 2. (2) Use a local buzzer or bell rated less than 24V DC, 2.5A. T : PS-1225/S/UL Q : RY-PA relay YL : Yellow(2) BK : Black(2)
H 260 260 260 487 487 –
(1) W 186 339 492 186 339 –
D 2 2 2 2 2 –
H 230 230 230 457 457 264
(2) W 156 309 462 309 309 190
D 68 68 68 68 68 52
MULTI-UNIT ENTRY SECURITY
Wiring
Multiple box mounting; Keep a distance of 186mm between two box centers. (1) Front panel (2) Back box
Specifications (VC-M) Power source Power supply Communication
Wiring
Distance
12V DC, 80mA (intercom). 100mA (lamp) PS-1225S, PS-1225UL, PS-1225 Electronic buzzer rings VC-K station(s). (Freq.: 600Hz. approx.) Take (either) handset to reply. Single open channel. 4 common + no.(residences), in loop. VC-M ~ VC-K: 35d looped. VC-M ~ power supply: 4d looped. VC-M to VC-K 330m(0.65mma) 800m(1.0mma) VC-M to PS-1215DIN 40m(0.65mma) 90m(1.0mma)
58
Open Voice Intercom COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
DOOR
ROOM
1
1 LEM-1DL Door station
Master station
Lineup VC-BBX
LE-DA
LE-D
AC-10S
Sub station m P.65
Sub station m P.65
Access control keypad, surface mount m P.99
LEM-1DL Master station
AC-10F Access control keypad, flash mount m P.99
EL-10S Electric door strike m P.101
LE-DL
Power supply PS-1225S PS-1225UL PS-1225 m P.103
Sub station m P.65
Features
Wiring
l Single door open voice access control system l Adjustable tarnsmit (front) and tone volumes l AC/DC power supply
(1)
300m / 0.8mma
LE-D
LEM-1DL 2
Communication network
2
M LE-D
1 E
1 E –
LEM-1DL
EL-10S 12V AC, 180mA
(
M
EL EL + –
)
H
(2)
LE-D
LEM-1DL 2
Unit dimensions LE-D
1 E –
LEM-1DL
M
2 1 E
EL-10S EL EL
120
83.5
180
PWR
29
88
143
LE-DA
53.5
Specifications (LEM-1DL)
LE-DL
83.5
175
83.5
115
Power supply Communication
10 120
25.5
Wiring Distance
59
H/T
(1) Using EL-10S door release (2) Using door release of other manufacture rated : 30V AC/DC, 1A max. Do not remove shorting link on LE-D. PWR : Power source
Power source
116
+ –
12~16V AC, 4VA 12~24V DC, 200mA (24V) AC transformer, PS-1225S, PS-1225UL, PS-1225 When called by tone, press TALK to reply. Press door release button to release door, and press OFF for standby. 2 wires, non-polarized (+2 for EL-10S) LEM-1DL to door 200m(0.65mma) 300m(0.8mma)
Open Voice Intercom MASTER
SUB
Master station
Door station
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
3 LEM
1
Room sub station
LE-D Sub station m P.65
LEM-1 1-call master
LE-A Sub station m P.65
LEM-3 3-call master
LE-DA Sub station m P.65
Power supply PS-0602D PS-0602C m P.103
LE-AN Privacy sub m P.65
Features
Wiring
l Open voice communication l Push-to-talk at master, hands free at remote l LE sub stations: either door station or room sub station l Voice volume control
300m / 0.8mma
LEM-1 LEM-1
LE-A 2
Communication network LEM-1 LEM-1
1 E
LE-A
1 E –
+ –
LEM-3
LEM-3
300m / 0.8mma
LE-D
300m / 0.8mma
LE-AN
LE-A
LEM-3 2x2
2
LE-A
LEM-3
LE-D
W
2
LE-AN 1
1 E –
2
LEM-1; Tone or voice. LEM-3; Selective call w/tone or voice. Tone and LED from sub
1 E –
E
Unit dimensions
3
LEM-3
+ –
★ Do not remove shorting link on subs.
180
160
LEM-1, LE-A, LE-AN
W
1 E –
W : PS-0602D, PS-0602C
Specifications (LEM) 131
51
143
LE-D
115
83.5 29
116
Power source Power supply Communication
83.5
LE-DA
120 88
53.5
10
Output Wiring Distance
6V DC, 200mA PS-0602D, PS-0602C Sub calls in w/tone and LED, 20 sec. Depress selector button and press or release TALK button. Sub called by tone or voice. Reply hands-free. 350mW output, adjustable 2 parallel wires per sub, non-polarized LEM to sub 200m(0.65mma) 300m(0.8mma)
60
Open Voice Intercom STATION
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
11 LEF Master station
Master station
LEF-3 3-call master
LEF-5
LEF-10
5-call master
10-call master
LEF-5W
LEF-10W
5-call master w/terminal box
10-call master w/terminal box
LEF-10S 10-call master (all call)
Power supply PS-1225S PS-1225UL PS-1225 m P.103 Features
Wiring
l Intermixable system with any number of masters and subs to max. capacity l Selective calling from any master with hands-free reply l LEF surface and LEF-C semi-flush units can be intermixed l Variety of sub stations are available l Weather-resistant door stations (any number) with selective door release l System options: PanTilt door/monitor(s), All Call/Music/Chime l Selective door release with LEF-5/10/10S (w/RY-PA)
Door answering w/selective door release 300m / 0.8mma LE-D #2
LE-D #1
LEF-5 4
3
3 C 2 3 4 5
1 1
LEF-5 LE-D
E
M
E
LEF-5 –
–
YL
M
Q Q
LEF-5 EL-10S EL-10S
Selective call between inside stations. Answering & releasing door from any inside station
Models LEF-3 LEF-5 LEF-10 LEF-10S
Capacity 4 stations 6 stations 11 stations 11 stations
Cable 9 wires 11 wires (+5: K1~K5*) 17 wires (+10: K1~K10*) 20 wires (+10: K1~K10*)
l K1 ~K10: Control terminals for video, door release. l LEF-3 does not have L terminal. l Door & inside sub stations can ring 2 or 3 LEF masters. l LEF All-master trunk cable=5 (or 6) common + no.of LEF (& subs)
61
1 C 3 4 5
1 2 C 4 5
1
2
3
E R Y + –
E R Y + –
E R Y + –
L
L
L
K4 K5
K4 K5
K4 K5
BK
H
C : PS-1225S, PS-1225UL, PS-1225 H : AC transformer Terminal 4 : for LE-D1, Terminal 5 for LE-D2. YL : Yellow(2) BK : Black(2).
Cabling
LEF-5 13
RY-PA's
Communication network
LE-D
LEF-5 13
T
Lineup
Room sub station
LE-D
LEF-20(S)*, 20-call master (photo) LEF-30(S)*, 30-call master LEF-40(S)*, 40-call master *Not available in Europe, Australia,
LE-A3
Sub station m P.65
3-call sub
LE-A Sub station m P.65
EL-10S
RY-PA
Electric door strike m P.101
Door release relay m P.101
LEW-5 LEF-5 terminal box
LEW-10 LEF-10 terminal box
nor New Zealand
LEW-10S LEF-10S terminal box
All call, music & chime
LE-DA
LE-AN3
Sub station m P.65
3-call privacy sub
LE-AN
AC-10S
BG-10C
Access control keypad, surface mount m P.99
All call, chime & music adaptor m P.65
Privacy sub m P.65
Access control keypad, flush mount m P.99
Unit dimensions LEF-3
Intermixed configuration
LEF-5, 10, 10S
3
BG-10C
LE-D
18
3
LEF-10S
LEF-10S LEF-10S LEF-10S 22 22 22
131 53.5
143 LE-A3, AN3
1 1 E
E
–
–
EL-10S
H
P1 P2 P3 + –
YL BK
Q Q
C 2 3 4 5 6 7 8 9 10 1 E R Y + – L
1 C 3 4 5 6 7 8 9 10 2 E R Y + – L
1 2 C 4 5 6 7 8 9 10 3 E R Y + – L
1 2 3 C 5 6 7 8 9 10 4 E R Y + – L
K9 K10
K9 K10
K9 K10
K9 K10
P1 P2 P3
P1 P2 P3
P1 P2 P3
P1 P2 P3
T
3 wires per sub. Run 3 wires to subs individually, or use multi-conductor cable to wire multiple subs (2 common + 1 per sub). l LE-D call-in chimes on LEF stations. l Only LEF-10S station can transmit all call. l Match door release control terminals (Kn) with door selector #10 with K10, #9 with K9. ★ Remove a shorting link on LE subs. T : PS-1225S, PS-1225UL, PS-1225 H : AC transformer Q : RY-PA
BG-10C 165
1 2 3 4 5 6 7 8 DB DA 11 E R Y + –
M
51
55
190
180
M
EL-10S
206
180
LE-D
LE-A, AN 160
Wiring
AC-10F
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Door station
250
143
77
53.5
Specifications (LEF) Power source Power supply Communication
Door release Selector switch Wiring
Distance
12V DC, 300mA per LEF station. PS-1225S, PS-1225UL, PS-1225 Sub calls in w/(chime) tone & LED, 20 sec. Depress the LED lit selector button. Use TALK/LISTEN switch. Master calls in w/tone or voice (no LED lit). Reply hands-free. To call, depress a selector, and call by voice or tone. Contact: 30V DC, 0.1A (resistance load). Contact: 12V DC, 30mA. 5 wires common + no .LEF (& subs) (all-master system) 2 wires per sub (single-master system). * E to - link remains attached. LE subs: 3 wires with the link removed (when intermixed) Farthest LEF’s 200m(0.65mma) 300m(0.8mma)
Specifications (BG-10C) Power source All call transmit All call receive Chime tone transmit Controls Wiring Distance
12V DC, 2.5A (music max. output). 1.5A(music, chime & all call). 0.1A standby From LEF-3C, 5C, 10C & LEF-1C and LEF-10S All LEF master station, and LE-C, CN AUX R, E and AUX L, E Music on/off. 11 selector switches of music & chime, chime only or off. 19 wires max. BG-10C to LEF-10C. 3 wires to each LE-D, DA. BG-10C to LEF-C 150m(0.65mma). 230m(0.8mma) LE-D/DA to BG-10C 200m(0.65mma). 300m(0.8mma).
62
Open Voice Intercom COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
DOOR
ROOM
3
8 LEF-C
Door station
Master station
Sub station
LE-D Sub station m P.65
LEF-3C
All call sub master Sub station *Not available in Europe
LEF-5C
LEF-10C
5-call master
10-call master
LE-BN* Privacy sub *Not available in Europe
LE-C* Sub station w/MUSIC receive volume control *Not available in Europe
LE-CN*
Power supply PS-1225S PS-1225UL PS-1225
Privacy sub w/MUSIC receive volume control *Not available in Europe
m P.103
Features
Wiring
l Intermixable system with any number of masters and subs to max. capacity l Selective calling from any master with hands-free reply l LEF surface and LEF-C semi-flush units can be intermixed l Variety of sub stations are available l Weather-resistant door stations (any number) with selective door release l System options: PanTilt door/monitor(s), All Call/Music/Chime l Selective door release with LEF-5/10/10S (w/RY-PA)
LEF-10C✕7 (20)
1 2 3 4 5 6 7
LE-D
1
LEF-10C
LE-D
LEF-10C
LEF-10C
E –
LE-B
LEF-10C
LE-B
BK YL Q
LE-B
H
EL-10S
DA
–
9 10 11 E R Y + – P1 P2 P3 + –
DCIN
Power source Power supply Communication
LEF-1C LE-B/BN LE-C/CN
15.5
15 20
200
15.5
40
20
208
200
208
238
Output
153
3
3
1 C 2 3 4 5 6 7 8 9 10 1 E R Y + – L P1 P2 P3
1 C 2 3 4 5 6 7 8 9 10 2 E R Y + – L P1 P2 P3
1 2 3 C 4 5 6 7 8 9 10 3 E R Y + – L
1 2 3 4 C 5 6 7 8 9 10 4 E R Y + – L
1 2 3 4 C 5 6 7 8 9 10 5 E R Y + – L
1 2 3 4 5 6 C 7 8 9 10 6 E R Y + – L
1 2 3 4 5 6 C 7 8 9 10 7 E R Y + – L
P1 P2 P3
P1 P2 P3
P1 P2 P3
P1 P2 P3
P1 P2 P3
3
1 1 E
E
1 E
–
–
–
T
Specifications (LEF-C)
Unit dimensions LEF-5C LEF-10C
LE-B/BN✕3
20
20
20
20
BK : Black(2) YL : Yellow(2)
Intermixed configuration Internal communication by Selective call. Sub calls in with tone & LED 20 sec.
LEF-3C
20
T : PS-1225/S/UL Q : RY-PA relay H : AC transformer
LEF-10C
LEF-10C
LEF-10C
20
3 BG10C
Communication network
63
LEF-1C
LE-B*
3-call master
153
Door release
15.5
15 20
Selector switch Wiring Distance
12V DC, 300mA per station. PS-1225S, PS-1225UL, PS-1225 Sub/door calls in w/tone & LED, 20 sec. Depress the LED lit selector button. Depress TALK/LISTEN switch. The LED stays lit while in use. Single talk channel w/OCCUPIED lit. 800mW at 20d (receive). 500mW at 20d (transmit). Contact: 110V AC, 1A. 24V DC, 1A. (on RY-PA output). Contact: 12V DC, 1A. (K terminals) 5 or 6 common + no. all stations Farthest LEF-C’s 200m(0.65mma) 300m(0.8mma)
Open Voice Intercom
Scheduled to stop production
ROOM
3
8 LEF & MYW-P1L/P3L
Door station
Door adaptor
*Not available in Europe
Lineup
Master station
RY-PA
EL-10S
Door release relay m P.101
Electric door strike m P.101
MYW-P1L Single PanTilt door adaptor
MK-DBC Video door station
MYH-CU
LEF-10
Video-monitor
10-call master
MYW-BA Long distance adaptor m P.22
MYW-P3L 3 PanTilt door adaptor m P.20
Power supply PS-1225S PS-1225UL PS-1225 m P.103 PS-1820S PS-1820UL PS-1820 m P.104 Features
Wiring
LEF & MYW-P1L l Single PanTilt door & two or more video monitors l Electronic tone call-in l Door selection & reply from any LEF master station l Hands-free video monitoring LEF & MYW-P3L l 3 PanTilt doors & two or more inside monitors l Selective door release activation l Hands-free video monitoring l Audio & video monitoring from any master/monitor station l Surface & semiflush video monitors
75m / 1.0mma
100m / 1.0mma
MYH-CU & MYH-CU & MYW-P1L LEF-5 LEF-5 6 6
MK-DGC 2
M A1 A2
U
MK-DGC
2
EL-10S
T Q H YL BK
M MYH-CU & LEF-5
C 2 3 4 5 1
1 C2 3 4 5 2
1 2 C3 4 5 3
1 2 3 C4 5 4
1 2 3 4 5 C2
+ –
E R Y + –
E R Y + –
E R Y + –
E R Y + –
E R Y + –
KA
L K5
L K5
L K5
L K5
L K5
l Run audio & video wires in separate jacketed cables.
Specifications (MYW-P1L)
Unit dimensions
Power source
83.5
230
83.5
210
83.5
190
Power supply Communication
MYW-P3L
Wiring
2-gang 155 42
155
ON
A1 B1 A2 B2 U1 U2 + –
T : PS-1225/S/UL U : PS-1820/S/UL Q : RY-PA H : AC transformer BK: Black(2) YL: Yellow(2)
LEF-5
MYH-CU
LEF-5 13
13
Door call-in with tone, LED and image. PanTilt viewing. Selective call between rooms
MYW-P1L
LEF-5 13
A1 B1 A2 B2 U1 U2 + –
E R
LEF-5
6 OFF
A1 B1 A2 B2 U1 U2 + –
DA
LEF-5
MYH-CU & LEF-5
LEF-5 13
Communication network
80
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
DOOR
43
50
Distance
MYW-P1L: 18V DC, 500mA. 100mA standby. MYH-CU: 0.4A. OA standby. PS-1820S, PS-1820UL, PS-1820 (video) Door calls in w/tone & LED, 20 sec, image 45 sec. timed. Depress a lit selector button. Press TALK button to reply. Communication times out in 2-1/2 min. Press MONITOR button to reactivate. 2 parallel wires to door, non-polarized. 6 wires in loop, MYW-P1L to monitors. 6 wires, MYW-P1L to LEF MYW-P1L to door 100m(1.0mma) MYW-P1L to MYH-CU1 75m(35m w/2 monitors)(1.0mma)
64
LE Sub stations & Accessories Weather-resistant sub
Sub station
LE-DA
88
Sub station
29
116
83.5
175
115
120
LE-D
LE-DL
83.5
LE-DA
83.5
LE-D
10 25.5
120
LE-DL Sub station LE-DA; 2-gang mounting
Room sub
Semiflush mount sub
*Not available in Europe
Unit dimensions LE-A, AN
160
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Unit dimensions
131
LE-A
LE-AN
Sub station
Privacy sub
LE-B
LE-BN
Sub station
Privacy sub
LE-C
LE-CN
Sub station
Privacy sub
51
LE-C & LE-CN: w/MUSIC receive volume control
3-call sub
All call sub master Unit dimensions
Unit dimensions LEF-1C LE-B/BN LE-C/CN
180
208
LE-A3, AN3
153
143
LE-A3
LE-AN3
3-call sub
3-call privacy sub
15.5
15 20
53.5
LEF-1C All call sub master
All call/music/chime adaptor Specifications (BG-10C)
Unit dimensions
Power source 165
BG-10C
250
BG-10C All call, chime & music adaptor
65
77
All call transmit All call receive Chime tone transmit Controls Wiring Distance
12V DC, 2.5A (music max. output). 1.5A(music, chime & all call). 0.1A standby From LEF-3C, 5C, 10C & LEF-1C and LEF-10S All LEF master station, and LE-C, CN AUX R, E and AUX L, E Music on/off. 11 selector switches of music & chime, chime only or off. 19 wires max. BG-10C to LEF-10C. 3 wires to each LE-D, DA. BG-10C to LEF-C 150m(0.65mma). 230m(0.8mma) LE-D/DA to BG-10C 200m(0.65mma). 300m(0.8mma).
Handset Intercom MASTER
SUB
Master station
Sub station
Lineup
TAR-3
Boxed set
External signaling relay m P.102
AT-406 Boxed set (white color)
AT-406P Display pack
AT-406B/A Boxed set (charcoal gray)
AT-306 Sub station
Master station
Power supply PS-0602D PS-0602C or Batteries m P.103
Features
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
3 AT-406
1
Wiring
l Handset master-sub intercom w/2 additional subs (optional) l Battery status LED l Batteries or DC power supply l Buzzer or bell activation (optional) AT-306
AT-206 2
AT-306 2
AT-306 2
Communication network 1 2 AT-206
W
AT-306 x 3
1 2
NP
NP
1 2
NP
1 2
+ ---
W : PS-0602D, PS-0602C
Specifications (AT-406) Master calls all the subs simultaneously, while the sub rings the master only.
Power source Power supply
Unit dimensions
Communication AT-206 AT-306
210
83.5
Wiring Distance
80
6V DC, 150mA PS-0602D, PS-0602C or Batteries gAAh (SUM-3) x 4 pcs Press CALL button to ring all subs. Pick up any phone. Sub rings master only. Common talk. 2 parallel wires. non-polarized 2-station set 700m(0.65mma) 1000m(0.8mma) AT-206 to subs 1~3 400m(0.65mma) 600m(0.8mma)
51
66
Handset Intercom STATION
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
25 TD-H/B Door station
Sub station
Master station
TD-1H/B
TD-3H/B
TD-6H/B
1-call sub
3-call master
6-call master
IF-DA Door station m P.30
DE-UR Door station adaptor
Power supply PS-1225S PS-1225UL PS-1225 m P.103
Wiring
Features l All-master selective ring system l Single-master configuration or intermix w/TD-1H/B l Multi-conductor cable in loop l Multi-talk channels l Door station(s), audio or PanTilt video (max. 2) l Zone paging, with or without talkback l Music source connection. Page pretone cuts out music.
(2) Door station communication 230m / 0.8mma
1000m / 0.8mma
IF-DA
DE-UR 1
1 2
1 2
2
TD-6H/B #1 10
#2
C 2 3 4 5 6
1 C 3 4 5 6
1 2 C 4 5 6
1 2 3 C 5 6
1 2 3 4 5 6
1
2
3
4
C
#3 10
#4 10
#5 10
Communication network
TD-12H/B
TD-12H/B
TD-12H/B
Paging Speaker
TD-12H/B
1 2 1 2
TD-12H/B
TD-12H/B
IF-DA
All-master configuration. Station selector & CALL to ring any other station.
Wiring (1) All-master configuration
C
D
D
D
D
D
D
D
+ –
+ –
+ –
+ –
+ –
+ –
+ –
A
B
T
1000m / 0.8mma
TD-12H/B TD-12H/B
C
#1
#2 16
#3 16
#11
#12 16
16
15m / 0.8mma
#13 16
(3) Single-master configuration TD-3H/B
C 2 3 4 5 6 7 8 9 10 11 12 1 D + –
1 C 3 4 5 6 7 8 9 10 11 12 2 D + –
1 2 C 4 5 6 7 8 9 10 11 12 3 D + –
T
1 2 3 4 5 6 7 8 9 10 C 12 11 D + –
1 2 3 4 5 6 7 8 9 10 11 C 12 D + –
1 2 3 4 5 6 7 8 9 10 11 12 C D + –
l Install main cable of max. condctors allowed for each TD-H/B station model. C : PS-1225S, PS-1225UL, PS-1225 Terminal D : Door station
67
TD-1H/B 6
C 1 2 3
TD-1H/B 5
1 C
TD-1H/B 4
1
1
C C
D
T
+ –
+ –
+ –
+ –
Terminal 5 for door 1, 6 for door 2. DE-UR’s should be powered by power supply.
Lineup
PD-1 Zone page adaptor
For desk-top or surface wall mounting, provide TDW-n/A terminal box w/1.5m cord.
TD-6Z/A 6-call master station
TD-12Z/A 12-call master station
TDW-1/A TD-1H/B terminal box
TDW-3/A TD-3H/B terminal box
TDW-6/A TD-6H/B terminal box
TDW-12/A TD-12H/B terminal box
TD-12H/B
TD-24H/B
12-call master
24-call master
TDW-24/A TD-24H/B terminal box
full trunk all-master configuration l No break-in call l Zone page(s) in lieu of station(s)
Power supply PS-1225S PS-1225UL PS-1225
RY-AC/A External signaling relay m P.101
Specifications (TD-H/B) Power source Power supply Communication
(4) Straight paging w/PD-1 (single-zone) PD-1 (1) TD-12H/B
3
(1)
T
Wiring
A G M
No.
C
DC12V
+ ---
+ ---
TD-H/B
+ ---
Distance
T (2)
Power source Power supply Communication Wiring Distance
PD-2 TD-12H/B
(1)
3
T (1)
S S V V A G M
Power source
No.
DC12V
+ ---
+ ---
+ ---
TD-H/B
T T : PS-1225S, PS-1225UL, PS-1225
(1) Paging Speakers (2) Talkback speakers
Unit dimensions PD-1 PD-2
TD-24H/B
210
83.5
83.5
138
210
TD-1H/B ~ TD-12H/B TD-6Z/A, TD-12Z/A
91 73
100
12V DC, 90mA per channel PS-1225S, PS-1225UL, PS-1225 Depress a selector and CALL to ring opponent. 3 + no. TD-Z/A in loop. TD-Z/A stations 650m(0.65mma) 1000m(0.8mma)
(PD-1,PD-2)
(2)
C
12V DC, 70mA per station. PS-1225S, PS-1225UL, PS-1225 Depress a station selector 1~12 and CALL (or CALL A) to ring station 1~12 (or A1 ~ A12). Lift handset to reply. Door calls in w/standard or faster(B) intermittent tone, 2-1/2 sec. Pick up and depress the selector assigned. 2 or 3 + no. TD-H/B in loop. TD-1H/B: 4 wires. TD-3H/B: 7 wires. TD-6H/B: 10 wires. TD-12H/B: 16 wires. TD-24H/B: 28 wires. TD-H/B stations 650m(0.65mma) 1000m(0.8mma) DE-UR to door 150m(0.65mma) 230m(0.8mma)
(TD-Z/A)
(5) Paging with talkback w/PD-2 (single zone)
100
Zone page/talkback adaptor
l 7 or 13 identical station,
m P.103
Wiring
PD-2
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Privacy type
Output Paging & music tone controls Amp. input Music input Tuner output Tape output Talkback gain Environmental noise Paging Wiring
PD-1: 12V DC, 300mA. PD-2: 12V DC, 48mA (talkback). 5Kd . Max. 1.5V Treble 12dB at 10KHz. Bass 12dB at 100Hz. AUX or PHONO 100K-500Kd, 0.12~0.5V 17Kd, 0.3V, 1KHz. for full output Audio output: Range 100mV~1.2V, 10Kd or less Low level output: Range 100mV~1.2V, 600d 40dB, 1KHz. at max. volume Less than 80dB (phon) Select an assigned selector # and page w/PAGE button depressed. Release to receive reply 3 wires to TD-H/B via power supply
51.5
83
68
Handset Intercom DOOR
Scheduled to stop production
ROOM
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
24 TD-H/B & MY-CU
1
Door station
Adaptor
*Not available in Europe
Master station
Lineup
EL-10S Electric door strike m P.101
DE-UR Door station adaptor
MK-DBC Video door station
TD-12H/B 12-call master
MYW-BA
MY-CU
Long distance adaptor m P.22
Main video monitor
MYH-CU Sub video-monitor
Power supply PS-1820S PS-1820UL PS-1820 m P.104
PS-1225S PS-1225UL PS-1225 m P.103
Features
Wiring
l Single PanTilt door integration with three monitors, expandable l Hands-free video monitoring or handset audio / video monitoring
100m / 1.0mma MK-DBC
35m / 1.0mma
MY-CU 2 2
1A1 B1 1A2 B2
1A1 B1 1A2 B2
1A1 B1 1A2 B2
U1 U2 + ---
U1 U2 + ---
U1 U2 + ---
U
DE-UR
TD-12H/B & MYH-CU
1 2
D1 E D2
C EL EL
H
EL-10S
D + ---
TD-12H/B
TD-12H/B & MYH-CU
TD-12H/B TD-12H/B 16 16
16
Communication network
MK-DBC
TD-12H/B 16
DE-UR A1 A2
TD-12H/B & MY-CU
6
TD-12H/B 4
M
MYH-CU
MYH-CU 6
T
T : PS-1225/S/UL
C 2 3 4 5 6 7 8 9 10 11 12 1 D + ---
1 C 3 4 5 6 7 8 9 10 11 12 2 D + ---
U : PS-1820/S/UL
1 2 C 4 5 6 7 8 9 10 11 12 3 D + ---
1 2 3 C 5 6 7 8 9 10 11 12 4 D + ---
H : AC trans.
Specifications (TD-H/B & MY-CU) Power source
PanTilt viewing
Unit dimensions Power supply TD-12H/B & MY-CU(MYH-CU)
DE-UR
50 100
69
155
73
150
83.5
160
83.5
210
Communication
45
Door release Wiring Distance
TD-H/B: 12V DC, 70mA per station. MY-CU: 18V DC, 0.9A max. MYH-CU: 18V DC, 0.4A. PS-1225S, PS-1225UL, PS-1225 (TD-H/B). PS-1820S, PS-1820UL, PS-1820 (video). Door calls in w/intermittent tremolo and image 45 sec. Rings max. 12 stations. Pick up (any) handset and depress a selector assigned to reply. Image stays on 2-1/2min. Reactivate w/MONITOR button. 30V DC or 250V AC, 5A (resistance load) 2 parallel wires to door. 6 wires, monitors MY-CU to door 50m(0.65mma) 100m(1.0mma) MY-CU to MYH-CU1 35m(0.65mma) 75m(1.0mma) MY-CU to MYH-CU1-2 17m(0.65mma) 35m(1.0mma)
Handset Intercom STATION
Phone extension
Lineup
YAW-RB
1-zone paging adaptor for YAZ-90-3W
Power supply PS-2420S PS-2420UL
YAZ-90-3W Phone master station
m P.104
Features
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
90 YAZ-90-3W
Wiring
l Microprocessor built-in intercom expandable to max. 90 stations on 4-pair cable l Up to 2.9km wiring distance l Zone paging l Communication functions: Camp-on busy, secretary transfer, call transfer l Line-off trouble on one channnel does not affect the other channels
Communication network YAZ-90-3W Paging Speaker
YAZ-90-3W
2900m / 0.8mma #10 4P
YAZ-90-3W
#39
#40
3P
4P
YAZ-90-3W YAZ-90-3W
YAW-RB
1 2
1 2
1 2
1 2
3 4
3 4
3 4
3 4
5 6 + –
5 6 + –
5 6 + –
5 6 + –
N
N
M G A
Paging amp. IN
OUT
Paging speaker line
shielded White
Power relay AC
TB P G
White
Paging speakers
Power supply (for relay)
l Remove +,- wires between YAZ stations of different blocks. Within a block locate a power supply in the center of cable run, and make groups of max. 10 YAZ stations. As shown, connect +, - wires from the power supply to each group's initial YAZ station. N : PS-2420S, PS-2420UL, PS-2420
YAZ-90-3W
YAZ-90-3W
Specifications (YAZ-90-3W) Power source Power supply Communication
Station to station communication in any pair
Unit dimensions
Line loop resistance Wiring Total wiring distance
YAW-RB
YAZ-90-3W
24V DC, 150mA max. 20mA standby. PS-2420S, PS-2420UL, PS-2420 per 30-station block. Dial 2-digit station # to ring other station with tone or voice pressing PAGE. Privacy communication on each channel (max. 3). Must not exceed 200d for farthest stations. 20d for power line. 4-twisted pairs (shielded) in loop. Farthest YAZ’s 1900m(0.65mma), 2900m(0.8mma)
158
83.5
230
Specifications (YAW-RB)
152
Power source Consumption Paging impedance/level 59
Music impedance/level 94
84
Line resistance Amp. power ctrl. contact
YAW-RB: 24V DC, 150mA (paging).40mA (standby). YAW-RB = 5 YAZ’s, powered by YAZ network. Input: 600d/78mV(RMS), 1KHz. Output: 600d/300mV(RMS), 1KHz. Input: 20Kd/300mV(RMS), 1KHz. Output: 600d/150mV(RMS), 1KHz. 20d loop for power supply line. 200d loop for intercom line. YAW-RB: 240V AC 10A. 24V DC, 10A.
70
Integratable Audio & Video Security MASTER
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
8
DOOR
120 AX Central exchange unit
Master station
AX-084C Central exchange unit, 4 masters and 8 doors
AX-8MV
AX-8M
8-call color monitor master station
8-call audio master station
AX-248C (Photo) Central exchange unit, 8 masters and 24 doors
AX-320C Add-on exchange unit, 32 doors
AX-16SW
Power supply PS-2420S PS-2420UL PS-2420 m P.104
AX-8MV, AX-16SW
16-call add-on selector
Features l Up to 120 video entrance stations and 8 master stations l All wired on CAT5e, homerun cabling l Total hands-free, auto-voice actuation, communication or Press-to-talk operataion l Two talk channels and two video channels. l Communication privacy l Masters available with 3.5 inch color TFT LCD l Selective door release l Master-to-master selective calling and All Call l Standard or Priority call levels from door stations l Scan monitoring: Hands-free audio/visual monitoring l Video output from CEU and AX-8MV l Integrate with CCTV, Access control etc. l PC interface for programming and event logging l Rack or wall mountable CEU l Compatible with IE Series door stations l Optional features: headset, footswitch, and PC remote control
Communication network
AX-DV
AX-8MV
AX-8MV AX-DVF
Video signal
PC programming
AX-DM
Monitor
Calling & communication (w/video from door) Door release
71
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Door station
Lineup
EL-10S Electric door strike m P.101
AX-DV Color video door station surface mount
AX-DM
AX-DVF Color video door station flush mount
Audio door station Mullion type
AC-10S Access control keypad, surface mount m P.99
IF-DA Audio door station
AX-DV-P Color video door station w/space for embed proximity reader surface mount
AX-DVF-P
AC-10F
Color video door station w/space for embed proximity reader flush mount
System Integration
Access control keypad, flush mount m P.99
IE-JA Audio door station
Cabling 300m
300m
Video signal CAT5e
AX-8MV
AX-DV
Security Integration Software Switch camera
System log
PC
AX System
AX-084C
CCTV System
Remote door release
Video signal
AX-8MV
AX-DVF-P
CAT5e CAT5e
Calling & Communication with video
Door release
CAT5e
AX-DVF
PS24 PS24
Door release history
CAT5e
Remote door release
AX-DM
Monitor
Card ID RS232C Door release
Access Control System
Access Control System
PC
Camera CCTV Switcher
Monitor VCR
72
Integrated Security & Communication System Wiring
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
300m
300m
AX-8MV Cat5e
AX-DV
Cat5e
M
2
AX-248C AX-DVF
AX-8MV
Cat5e
Cat5e
M
2
2
2
N N
AX-8M Cat5e
AX-DM
Cat5e
M
2
Master #1 AX-8MV
Door #1 AX-DV Cat5e RJ-45
Brown Red Yellow Orange Green Blue
Cat5e RJ-45
Door #2 AX-DVF
EL-10S Cat5e
H AX-248C
PC
Master #2 AX-8MV
RJ-45 RJ-45
H EL-10S
Door #24
Red
AX-DM Brown
3(White green) 6(Green) 7(White brown) 8(Brown)
1 2 4 5
N N
Cat5e Cat5e
Master #8 AX-8M
Cat5e EL-10S
H
RJ-45
N : PS-2420S, PS-2420UL, PS-2420 H : AC transformer
Mountain locations
73
Master station
Video door station
Install the video master station in a place where the screen is not exposed to direct sunlight.
Do not install a video door station in any of the following locations where lighting or the ambient environment could impact the display on the video master station due to the characteristics of the door station's camera. 1. Locations subject to direct sunlight 2. Under street lights or door lights 3. Other locations subject to strong lighting conditions
Video + Video IER-2 Foot switch
Components
AX-8MV (AX-8M audio only)
AX-16SW
Number of master stations
Number of add-on selectors per master
1~8
up to 4
9 ~ 24
AX-DVF
AX-DM
Number of door stations
AX-084C or AX-248C
AX-320C
Number of central exchange unit
Number of add-on exchange units
AX-084C
AX-248C
-
1
-
-
up to 8
1
-
1
-
25 ~ 40
up to 4
2
1
-
1
41 ~ 56
up to 8
3
-
1
1
57 ~ 72
up to 4
4
1
-
2
73 ~ 88
up to 8
5
-
1
2
89 ~ 104
up to 4
6
1
-
3
105 ~ 120
up to 8
7
-
1
3
NOTE: Use the AX-248C for systems with more than 4 master stations (may effect the required quantity of AX-320C). 2 pcs of power supplies are required for video system.
Image view area
Unit dimension AX-8MV
• AX-DV, AX-DVF AX-DV-P, AX-DVF-P
AX-8M
185cm
★
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
AX-DV
★
175
175
65cm
50cm
120cm
★
150cm
★
95cm 50cm
194
63
AX-16SW
★
63
194
approximate
AX-320C
AX-084C, AX-248C
Specifications Power source Power supply Current consumption
88 85
420 426
88 85
175
420 426
Calling 63
AX-DV-P
100
Communication
AX-DVF
245
195
AX-DV
246
86
Video monitor Scaning lines Night viewing
25 146 100
AX-DVF-P
2 45
Door release contact Outside video output
25
IF-DA 130
AX-DM
295
160
1-gang
98
Wiring Wiring distance
28
IE-JA
146
22.5
115
43
2-gang
2 45 116
24V DC, 2A (Two Power supplies required per video system) PS-2420S, PS-2420UL, PS-2420 AX-084C: Video (Max.) 650mA, Audio (Max.) 700mA AX-248C: Video (Max.) 1150mA, Audio (Max.) 1250mA AX-320C: Video (Max.) 280mA, Audio (Max.) 180mA Normal call: an intermittent tremolo Priority call: a rapid intermittent tremolo Approx. 10-600 sec. or infinite AUTOMATIC (Hands-free); To activate, momentarily press TALK button. MANUAL (Press-to-talk/Release-to-listen); To activate, press TALK button for 1 sec. or more. Approx. 30-600 sec. 3.5 inch direct view TFT color LCD 525 lines Up to 30cm from camera, with white LED projected, background beyond 30cm cannot be seen. 24V AC/DC, 0.5A AX-084C, 248C: NTSC standard 1Vpp (0.7-1.4Vpp) BNC x 2 Switching signal: Open collector output 24V DC, 30mA RJ-45 x 2 AX-8MV: NTSC standard 1Vpp (0.7-1.4Vpp) Homerun CAT5e wire to CEU CEU to door: 300 m (CAT5e) CEU to master: 300 m (CAT5e)
10
74
Commercial Security Intercom MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
64 1,024 AI-900 Master station
Sub station
AI-RS150
AI-RS170
Substation, indoor m P.77
Substation, outdoor m P.77
AI-RS160
AI-RS180
Substation, indoor m P.77
Substation, outdoor emergency m P.77
AI-MS900 Master station m P.77
Features l Flexible All-modular construction. Expansion options using interface and function cards. l Sub-to-master communication by voice switch or PTT-activated talk-back. Master-to-master by full-duplex handsets. l Four different substations for specific installation conditions. l Provides a speaker and call button. l Basic conversation plus full range of exchange functions, including; Call forwarding, Scan monitoring, Emergency conference, Conversation recording by way of external equipment, and Paging by way of an external amplifier. l Emergency calls from any substation at a central security control room. l Efficient voice recording at ea. master station. l Used in combination with CCTV, access control, emergency broadcast systems or other security equipment.
Communication network
(1)
AI-MS900
(2)
(3) (6) (4)
(5)
J Calling & Communication (1) Speaker (2) Substations (3) Cordless Phone (4) Access Control (5) CCTV (6) Personal computer. PC Link with programming and monitoring software.
75
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Mounting accessories
AI-YC303 AI-900MF wall-mounting bracket m P.78
AI-PU200
AI-900MF
Power transformer unit m P.78
Main frame m P.78
AI-PN100B AI-PU200 rack-mount panel m P.73
Cabling
Wiring AI-900MF
1. AI-MS900 (1)
AI-900RS AI-900MS CN1 CN1 CN2 CN2 CN3
AI-MS900
C/O
(2) (3)
1-(1)
CN4
AI-900MF
AI-900MF
(4)
CN3
1-(1) 2. AI-900AL Tel
AI-RS150~180
AI-MS900
2-(1) 2-(2)
2C
(5)
3. COM1 3-(1)
3-(3)
Modem
Program PC
RS-232C
RS-232C
4-(1) 5. AI-900AF
l To double the size of the system; Two Tie-line I/F cards are required (after that, add one I/F card for each add’l main frame). (1) Outside line (2) PC (for programming and system maintenance) (3) External paging equipment (4) Substation paging amplifier (5) shielded
AMP(1) AMP(2)
COM1
INPUT 1P
OUTPUT
7-(1) 8. AI-900TI 2P 2P 2P 2P
2. AI-900MF DC24V IN
RS-232C
AI-900AF CN4 AC-IN CN5 CN8
AMP (16)
7. EXT. AMP.
9. AI-PU200
COM2
4-(2) 1P 1P 1P
15. LIN. 16. LIN.
2C
3-(4)
Operation log PC
2. LIN.
CN6
RS-232C
4. COM2 3-(2) Modem
l Basic system consists of; 4 Master stations, 64 Substations and AI-900MF Main Frame with Interface Cards; Master(1), Telephone(1), Substation(4), Outside line(1), Audio function(1), and power unit(2).
1P 1P
1. LIN.
CN5
AI-900AL CN1 AI-900TI CN2 CN1 CN3 CN2 CN4 CN3 CN4
1P 1P
Tel
2P
CN4
AI-RS150 ~ AI-RS180
6. AI-900RS
AC-IN
24V DC AI-PU200 4 4
~ (N, L) AI-PU200
~ (N, L)
1. Master station Interface card 1-(1)To External Record device. 2. Telephone Interface Card 2-(1),(2)To External Recording device 1, 2. 3. Programming PC Connection COM1 3-(1) Via Modem. 3-(2) RS-232C cross cable. 3-(3) Direct connection. 3-(4) RS-232C straight cable. 4. Operation Log PC Connection COM-2 4-(1) RS-232C cross cable. 4-(2) RS-232C straight cable. 5. Audio Function Card (for paging) AMP(1)-(16): Amplifier. 6. Substation Interface Card 1.LIN.-16.LIN.: LINE1-16. 7. External amplifier 7-(1) Paging amplifier. . 8. Tie-Line Interface Card Exchange Interconnection 8-(1) 2C shielded (data line). 9. AI-PU200 Power Transformer.
76
Commercial Security Intercom
AI-900 Components
AI-MS900
The AI-MS900 can initiate or receive calls from programmed substations. Equipped with Pushto-Talk button for simplex communication, vox operated handset, redial and transfer keys, and eight auto-dial keys. Alphanumeric display for caller ID. Two-twisted pair wiring to Main Frame.
Unit dimensions 74.5
216
213
Features
Master station
Standard indoor substation Features
Unit dimensions
The AI-RS150 is built with a black resin call button and 14-gauge stainless steel. It can call and converse with the programmed master stations. All substation models are wired with a shielded pair to the Main Frame.
120
2
AI-RS150 Substation, indoor
120
48.5
Indoor vandal resistant substation Features
Unit dimensions
The AI-RS160 is made with heavy 11-gauge stainless steel and a vandal resistant stainless steel call button. Calls and communicates with programmed master stations or telephones.
3
120
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Master station
AI-RS160 Substation, indoor 120
57.5
Outdoor vandal resistant substation Features
AI-RS170
Unit dimensions
The AI-RS170 is equipped like the AI-RS160, but with the internal components protected with a synthetic rubber sealant, making it weather resistant. Calls and communication with programmed master stations or telephones.
120
3
Substation, outdoor 120
57.5
Outdoor emergency substation Features
Unit dimensions
The AI-RS180 is vandal and weather resistant with a red aluminum call button, call assurance LED, and an output to control an external relay. Used for ADA compliance or emergency call applications.
120
3
AI-RS180 Substation, outdoor emergency
77
120
58.5
Features
Unit dimensions
The AI-900MF Main Frame can accommodate the following features with the installation of the corresponding circuit cards. Up to 4 master stations or single line phones (2 masters per AI-900MS card; 2 phones per AI-900AL card); up to 64 substations; up to 2 CO lines; paging to 19 zones; tie line connection to additional Main Frame, RS-232 input/output for system programming and event logging.
AI-900MF Main frame
AI-900MF
443.7
The AI-PU200 has two 20V, 2.5A AC outputs. One unit is required for every two AI-900RS cards installed in the Main Frame. 420 483.6
The AI-PN100B is used to rack mount two AI-PU200 power transformers side-by-side.
AI-PU200
AI-PU200
The AI-YC303 is used to wall mount the AI-900MF Main Frame.
160
178
Power transformer unit
288.3
AI-PN100B AI-PU200 rack-mount panel 120
240V
250V 71A OUTPUT TO EX-200 TO FC-210 20V 2.5A 20V 2.5A
68
220V
AI-YC303 AI-900MF wall-mounting bracket
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Main frame
Interface cards AI-900MS Master Station Interface Card One or two cards per Main Frame. The AI-900MS card provides connection and audio recording outputs for one or two master stations. With two cards installed, four master stations can be connected to one Main Frame.
AI-900DI Direct-Select/Master Station Interface Board Used to create a direct-select style master station in place of a digital master. Used with AI-910DI for individual selector buttons and call-in LEDs. Also allows integration with external security systems via AI-910DI board.
AI-900AL Telephone Master Station Card One or two cards per Main Frame, used in lieu of AI-900MS card. The AI900AL allows a standard telephone with caller-ID capabilities to be used in place of a master station for communication functions. One or two phones per card, taking the place of an AI-900MS card supporting two master stations. Equipped with audio recording outputs for each telephone connected.
AI-910DI Direct-Select Input/Output Relay Board The AI-910DI is used in conjunction with the AI-900DI board to provide relay outputs to control external devices or systems. Each board contains 32 programmable relays, and multiple boards can be used for up to 1024 relays. Use for integration with access control and/or video surveillance systems.
AI-900RS, Substation Interface Card Up to four cards per Main Frame. Each AI-900RS card supports up to 16 substations, and up to 64 substations per Main Frame with four cards installed. Connect subs with simple two conductor shielded wire homerun to the Main Frame. AI-900CO C/O Telephone Line Interface Card One card per Main Frame. The AI-900CO allows the connection of up to two outside phone lines, with audio recording outputs for each line. Integration with outside lines allows communication between sub or master stations and standard telephones, cell phones, or pagers. AI-900AF Audio Function Card Connection of external PA amplifier for paging. Up to four inputs from audio sources and 16 outputs to external paging zones. Multiple zones or all zones can be selected and paged simultaneously. AI-900TI Tie Line Interface Card One card per Main Frame in multi-exchange system. The AI-900TI card is used to interconnect multiple Main Frames, expanding the capacity and functionality of the system. Up to four voice paths between Main Frames.
Specifications (AI-900) Power Source
Current consumption Communication Modes Serial Ports Operating Temperature System Capacity Master Station Mounting Master Station Wiring Substation Mounting Substation Wiring Wiring Distance: - Master to AI-900MS - Subs to AI-900RS - Between Main Frames
20V AC, 2.5A, provided by AI-PU200; 24V DC provided by external 5A power supply not supplied Aiphone 7A Duplex, half-duplex, and Push-to-Talk RS-232 compliant, D-sub connector ( 9-pin female) 2 ports -Indoor Units 0kC~40kC -Outdoor Units -10kC~55kC 4 master stations; 64 substations per Main Frame Wall or desk mount 2 twisted pairs, homerun to Main Frame Flush mount in 2-gang box 2 conductor shielded, homerun to Main Frame 900m(0.5mma). 1500m(0.65mma) 500m(0.5mma). 800m(0.65mma) 600m(0.5mma). 1000m(0.65mma)
78
Security Window Intercom System SERVICE SIDE
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
1
PUBLIC SIDE
1 IMU-100 Service Side
IMU-100 Main kit
IMU-100 IME-100 OU-100 Operation unit
IME-100 Gooseneck microphone
MU-100 Main unit
Power supply PS-2420S
PS-2420UL
PS-2420 m P.104
Features l First in industry! Using an acoustic tube with noise cancelling microphone l Voice-actuated hands-free communication l Flexible gooseneck type microphone l Optional Mono type headset (a3.5 plug) l Detection sensor switches automatically to communication mode l Separate speaker system using an optional microphone l Paging feature for announcements l Thin shape of the acoustic tube does not obstruct the field of vision l Holes in the barrier glass are not necessary to install
Communication network Acoustic tube system 3
Paging speaker
ISE-100
2
Barrier glass
IAI-100 + IAX-100
1
IMU-100 + IME-100 Service Side 1 2 3
Public Side
Voice-actuated hands-free communication Automatically switch to communication mode Paging
Separate speaker system 3
Paging speaker
ISE-100
2
External speaker
+ Barrier glass
IME-150 3
IMU-100 + IME-100 Service Side
79
Public Side
Acoustic tube system
Separate speaker system IAI-100 Acoustic interface kit
ISE-100
External Speaker (locally available) IAI-100 IAX-100
DR-100 Driver unit
Sensor
+ Paging speaker (locally available)
IAX-100 Acoustic tube
AI-100 Acoustic I/O tube
IME-150 Optional microphone
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Lineup
Public Side
Unit dimensions
Wiring 20m / (1.2mma)
IMU-100
Supplied cable
+
Cord (3.5m)
IME-100 IME-150
160
27
ISE-100
Paging speaker
130
40
210 49
Cord (3.5m) Shielded cable 2
370
External speaker +
24
388
2 Shielded cable
2
2
206
Mic.
2
AI-100
OU-100
45
Speaker
MU-100
Separate speaker system
IME-100 63
420
14.5
510
2
34
3800
40
IAX-100 24
N
1000
IME-150
W1 E – +
WHITE(C) BLACK(H)
3500
Shielded WHITE RED
Shielded WHITE RED
– SW +
PG OUT
C H
DC24V
+ –
84 150
68
Shielded(E) WHITE(-) RED(+)
Connection cord (approx. 3.5m) ST-BY SW
36
72 30
C H
105
W2
115
Connector
DR-100
23 60
Separate speaker system
ISE-100 3500
13
Supplied cable (approx. 2m)
27
Connection cord (approx. 3.5m)
Specifications (IMU-100) Power source Power supply Consumption Operating temperature Communication
W3
Headset
N
External speaker Paging speaker
N : PS-2420S, PS-2420UL, PS-2420
24V DC PS-2420S, PS-2420UL, PS-2420 120 mA (standby) 780 mA (maximum) 0kC to 40kC Voice-actuated communication Transmit output: 3 W 4 Ω, Receive output: 1.5 W 16 Ω a3.5 plug, Impedance: 32 Ω, Rated input: 40 mW or more, Maximum input: 100 mW or more Impedance: 4 to 8 Ω, Rated input: 3 W or more Maximum input: 6 W or more Impedance: 4 to 8 Ω, Rated input: 3 W or more Maximum input: 6 W or more
80
Master / Sub Intercom MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
120 NEM
1
Master station
Sub station
NB-L Ceiling sub station
NEM-10/C
NEM-20/C
NEM-30/C
NEM-40/C
10-call master
20-call master
30-call master
40-call master
NA-NE Sub station
NEM-10A/C NEM-20A/C 10-call master
NEM-30A/C NEM-40A/C
20-call master
40-call master
30-call master
NA-A
NA-AN
Sub station
Privacy sub station
Power supply PS-2420S PS-2420UL PS-2420 m P.104 Features
Wiring
l Lamp memory intercom: Sub’s call-in with tone & light l Press-to-talk or handset with voice actuation l Selective or group call of 10 subs l All Call l Pre-tone sounding at sub, when selected l Optional accessories for health care applications l Expand beyond 40 stations with add-on selectors
NEM-40A/C 1 2 3 4 10 EE
Communication network NA-A
NEM-40A/C
NA-A
NA-NE
NA-A
NA-A
NA-A
2
2
NA-NE 2
40 E
IER-2 NEM-40A/C 2xn
2.
NA-A 2
NA-A 2
NA-NE 2
NEM-40A/C 2 x n1
3.
NA-A
NA-A
2
2
NA-AN
NA-AN
NA-AN
81
2 x n2 2
2
NA-A
NA-A
OG/WH
BL GR BK
NA-NE 2
1 E
S S
PS24
+ -
Homerun 1 2 3 4
NE-JA
N : PS-2420S, PS-2420UL, PS-2420 NEM-60A
RD OG
31 32 33 34
Wiring NA-A
A B C D E
NA-NE
1. Selective individual call 2. Selective group call (max. 10) 3. All call
2xn
A B C D E
NA-NE
1. 2. 3.
1.
A B C D E
2
NA-NE
1. Run a parallel cable to each NA sub station (in the same conduit). 2. Run a multi-conductor cable(s) throughout system. 3. Run multi-conductor cables up to junction box, then run a parallel cable to each NA sub station.
A B C D E
A B C D E
NA-AN
NA-AN
RD OG OG/WH
BL GR BK
NA-NE
RD: Red OG: Orange OG/WH: Orange/White BL: Blue GR: Green BK: Black IMPORTANT: For NE-JA sub(‘s), homerun wires to secure stable calling and distance of 270m w/1.0mma.
NAR-6A
NB-U
Call button
Music adaptor m P.98
NE-JA Flush sub station
NBR-7AS Bathroom pullcord, moisture-resistant
NA-T/A(*1) Handset sub station
NEM-50
NEM-50A
50-call master
50-call master
NEM-60
NEM-60A
60-call master
60-call master
NEM-70
NEM-70A
70-call master
70-call master
NBJ-20(*2)
NBJ-20B(*2)
NEM-80
NEM-80A
80-call master
80-call master
NEM-90
NEM-90A
90-call master
90-call master
NEM-100
NEM-100A
Call switching device for NEM-10/C, 20/C m P.98
Call switching device for NEM-10A/C, 20A/C m P.98
100-call master
100-call master
NBJ-40(*2)
NBJ-40B(*2)
NEM-110
NEM-110A
110-call master
110-call master
NEM-120
NEM-120A
120-call master
120-call master
Call switching device for NEM-30/C, 40/C m P.98
Call switching device for NEM-30A/C, 40A/C m P.98
(*1 ) NA-T/A: Not available in Europe, Australia, nor New Zealand
NEW-5
IER-2
Dual master call adaptor m P.98
Call extension m P.101
(*2) NBJ-20/40, NBJ-20B/40B: Not available in Europe
Unit dimensions NEM-20/C NEM-40/C
N
+ –
N
+ –
346
446 596
496
NA-A, AN
NA-NE
NEM-120
NEM-80A
• NA-NE
142
NA-NE
NA-A NA-AN NAR-6A
A B C D E
RD OG
115
No.
NAR-6A
NA-T/A NE-JA
OG/WH
BLx2
BL GR BK
83.5
No.
116
10 (2-gang) 94
• NB-L NB-L No.
E
RD BK NAR-6A
GR
105
Specifications (NEM-40A/C) Power source Power supply Communication
BL OG OG/WH
BLx2
1. Power supply requirements One power supply for up to 40-call master Two power supplies for 50- to 80-call master Three power supplies for 80- to 120-call master 2. Adding call button to NA sub stations RD: Red BK: Black GR: Green BL: Blue OG: Orange OG/WH: Orange/White N : PS2420S, PS-2420UL, PS-2420
74
68
160
E E
BLx2
185
220
2. • NA-A, NA-AN
176 140
169
N
N
NEM-20A/C NEM-40A/C
232
N
1+ 1–
2+ 2– 1+ 1–
140 260
1.
260
Wiring
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Lineup
Output
Wiring Distance
24V DC, 45W max. 2.5W standby (NEM-40/C) PS-2420S, PS-2420UL, PS-2420 (40-call) Sub calls in w/tone & LED latching at master. Press TALK button to transmit, release to listen, or lift handset. At sub, pretone and voice when selected. Talk hands-free. Press ALL CALL button to activate all sub stations. 500mW max., adjustable. All Call: 6W, 12W. Selectively up to 10 subs w/TALK: 3W 2 wires per sub, non-twisted (1 common + no. Subs) NEM to NA subs 130m(0.65mma) 200m(0.8mma)
82
Master / Sub Intercom MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
100 TC-M
2
Master station
Add-on selector
IER-2 Call extension m P.101
TC-10M
TC-20G
10-call master
20-call add-on selector
TAR-3
TB-SE
External signaling relay m P.102
Sub station
Power supply PS-1820S PS-1820UL PS-1820
TC-40G 40-call add-on selector
TC-20M
TC-40GS
20-call master
W/add’l 20-/40-call expansion
Features
m P.104
Wiring
l Expandable internal telephone intercom l One or dual master configuration l Tone & LED call-in, staying on until answered l Additional buzzer at TB-SE (w/relay) l TRANSFER button on TC-M for communication between two TB-SE subs
900m / 1.0mma
TB-SE
TC-M 2
TB-SE
Communication network TB-SE TC-20M
TB-SE
*TB-SE
1 2 1 2 1 2 1 2 1 2 1 2 1 2
1
E E E
TB-SE
480 405 330 255
4 E
E
E
E
E
5
5
6
6
7
7 E E
E M C
E M C
E + 12V T S R S
83.5
210 230
210
72
S
TC-20G TC-40G
The TC-40GS is equipped with socket to connect the second add-on selector TC-20G or TC-40G.
10
+ 12V T S R
TB-AD1
1 E
IER-2
Specifications (TC-M) Consumption Power supply Communication
TC-40GS
E
l Run 2 parallel wires per TB-SE. Use any E terminal for max. three TB-SE’s. l Do not parallel TB-SE sub wires, or door station wires (in dual-TC-M system).
Power source
Wiring
8 E E
9.TB-SE
IER-2
E
1 TB-SE 2 1 2 1 2 1 2 1 2 1 2 1 2
9
1 2
1 E
80
3 E
E
115
555 630
1
E
4
10
TB-AD1
TB-SE 2
2
U
3
E
Unit dimensions
E
U
2
9
*TB-SE : Sub station for two-master call.
TC-10M TC-20M
TC-M 3 TB-SE 2 2
8
TC-20M
83
Lineup
Sub station
Wiring Distance
18V DC, 350mA. 15~16V AC, 50/60Hz, 750mA. 6W. 3W standby. PS-1820S, PS-1820UL, PS-1820, AC transformer. Pick up TB-SE handset. Rings TC-M, w/tremolo & LED, staying. At TC-M, pick up and press a lit selector to reply. 2 parallel wires per TB-SE, non-polarized. TC-M’s 200m(0.65mma) 480m(1.0mma) TC-M~TB-SE 400m(0.65mma) 900m(1.0mma)
Master / Sub Intercom DOOR
ROOM
Door station
Master station
Door adaptor
Lineup
IER-2 Call extension m P.101
TB-AD1
IF-DA
1-call door adaptor
Door station m P.30
TC-10M 10-call master
TAR-3
TC-10MD*
External signaling relay m P.102
TB-AD10
10-call master for door release *Not available in Europe
10-call door adaptor
Power supply PS-1820S PS-1820UL PS-1820
TB-ADD* 10-way door release adaptor *Not available in Europe
m P.104
Features
EL-10S Electric door strike m P.101
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
1 TC-M & TB-AD10
10
Wiring
l Single or multiple audio door communication, expandable l Optional selective door release control
IF-DA
TB-AD10
TC-10MD
TB-ADD
EL-10S
2 (x10)
Communication network
2
NP
PT
11
IF-DA TC-M+TB-AD10
1. 2.
1 2
D1
1 2
D2
1 2
D3
1 2
D4
1 2
D10
TB-ADD 10. EL-10S ( 10)
M
Pre-tone sounding or mute selectable at TB-AD10.
E
E E
TB-AD10
E
10
10
D10 DE
D10 DE
12V
12V
T R
T R
150
L2 L2 L3 L3
L10 L10
EL-10S
TC-20M + TC-20G
TB-AD10 1
97
Wiring
T
TC-20M
TB-AD1
L1 L1
L4 L4
U
230
83.5
140
42
2
D1 D2 D3 D4
TB-AD10 2
TB-AD10 3
IF-DA
D1 D2 D3 D4
PRE-TONE ON OFF
IF-DA
74
1 2 3 4
E
Unit dimensions TB-AD1
1 2 3 4
2 10
5
2
2 10
IF-DA 10
Multiple TB-AD10 installation; Add a power supply for TB-AD10 #3 or after.
1 2
1 2
N + – T R
2
U : PS-1820S, PS-1820UL, PS-1820
Specifications (TB-AD10)
U
TB-AD1 5 (x3)
TB-AD1
TB-AD1 2
19 20 + – T R
2
Wiring TC-20M
IF-DA
IF-DA
Power source Door capacity Communication
IF-DA
Distance
TB-AD10: 12V DC, supplied by TC-M. 10(TB-AD10). 1(TB-AD1). Door calls in w/tremolo & LED 40 sec. Pick up and depress LED lit selector. Pretone sounds at door, or silenced. 2 parallel wires to door, non-polarized. 4 common + no. doors, TC-M to adaptor. TC-M to TB-AD10 65m(0.65mma) 150m(1.0mma) TB-AD10 to IF-DA 150m(0.65mma) 360m(1.0mma)
84
Master / Sub Intercom DOOR
Scheduled to stop production
ROOM
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
1 TC-M & TB-ADM10
10 Door station
Master station
Door adaptor
*Not available in Europe
Lineup
Video monitor
MYW-BA Long distance adaptor m P.22
TC-10M
MK-DBC
10-call master
Video door station
TC-10MD
TB-ADM10
10-call master for door release
10-call PanTilt adaptor
MYH-CU
IER-2
Video-monitor
Power supply PS-1820S PS-1820UL PS-1820
Call extension m P.101
TAR-3 External signaling relay m P.102
TB-ADD 10-way door release adaptor
m P.104
Features
Wiring
l Max. 10 PanTilt video door communication l Optional selective door release control l Manual or auto video monitoring
MYH-CU MK-DBC 2 (x10)
6 TB-ADM10
TC-10MD
TB-ADD
NP
Communication network
1.
A1 A2
1A1 1A2
A1 A2
2A1 2A2
A1 A2
3A1 3A2
A1 A2
4A1 4A2
A1 A2
10A1 10A2
MK-DBC MYH-CU
2. 10. MYH-CU EL-10S ( 10)
TB-ADD
U1 U2
U1 U2
D1 D2 D3 D4
10 E
D10 DE
D10 DE
L1 L1 L2 L2 L3 L3
CN7A CN2
EL-10S
PS18
CN9 CN9
COAX OPTION
b b
Time lapse VCR control
l Each TC-M & TC-G has 2 sockets for plug-in connectors from TB-ADM10 with supplied junction cables. On TC-M, PanTilt selector # terminals must remain vacant. U : PS-1820S, PS-1820UL, PS-1820
Unit dimensions
Specifications (TB-ADM10)
92
MYH-CU : 2-gang mounting
210
83.5
MYH-CU
230
TB-ADM10
85
1A1 1A2
D1 D2 D3 D4
L10 L10
PRE-TONE ON OFF
PanTilt viewing
195
1A1 1A2
1 2 3 4
L4 L4
PS18
M
PT
11
CN1 CN11
TC-10M & TB-ADM10
EL-10S 2
155
50
Power source 18V DC, 700mA. Power supply PS-1820S, PS-1820UL, PS-1820 PanTilt door capacity10(incl. IE/IF audio). Call-in 40 sec. timed. MYH-CU image timer 2-1/2 min. timed. Auto-scan timer 60 min. max. w/duration 10, 20 or 30 sec. Press MONITOR 2 sec. to initiate. Wiring 2 parallel wires to door, non-polarized Distance TB-ADM10 to door 50m(0.65mma) 100m(1.0mma) TB-ADM10 to PS 5m(0.65mma) 10m(1.0mma)
Market-Com STATION
60 MC-60/4A
Market-com adaptor
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Market-com station
*Not available in Europe
Lineup Paging speaker w/built-in transformer (locally available)
MC-A/A Zone page adaptor
MC-60/4B Market-Com desk station *Not available in Australia nor New Zealand
Power supply PS-2420S PS-2420UL PS-2420 m P.104
MC-60/4A Market-Com station
Features
Wiring
l Max. 60-station paging & communication system l Selective 4 talk channels with in-use LED’s l Conference call among 3 stations l Music cutout during paging l Reinforced modular coil cord
MC-60/4A 10 3 7
2 7
S
1 7
7
1 7
2 7
3 7
MC-60/4A 10 7
#1
#2 MC
Communication network
7
7
7
7
7
7
7
7
#3
#4 MC-A/A A G M
(1) MC-60/4A
MC-60/4A (2) Ch.1 Ch.4
(1) Paging (2) Select a channel 1~4 paged, and communicate.
Unit dimensions MC-60/4A
#1- 10
3
2
1
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1/+ 2 3 4 5/– 6 7
N
MC-A/A
1
2
3
10 -#2
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
1 2 3 4 5 6 7
#3~#6
143
83.5
234
Station blocks #1~6 of max. ten MC-60/4A’s N : PS-2420S, PS-2420UL, PS-2420
Specifications (MC-60/4A) 91 90
51.5
94
Specifications (MC-A/A) Power source Amp. input Music soursce output
24V DC, PS-2420S, PS-2420UL, PS-2420 AUX 10Kd, 0.3V~0.5V Range 100mV~1.2V, 10Kd or less
Power source Power supply Communication
Talk channel Wiring Cable specified Distance
24V DC, 70mA max. (in page). PS-2420S, PS-2420UL, PS-2420 at MC-A/A. Pick up and depress channel selector 1~4 and page w/PAGE button. Called party picks up and presses lit LED channel button. 4 and a separate paging channel. 7 wires in loop, non-twisted. Line capacitance less than 25pF/30cm. MC-A/A to MC-60/4A(*) 500m(0.65mma) 750m(0.8mma) Total wiring distance 1500m(0.65mma, 0.8mma)
(*) MC-A/A to farthest MC-60/4A, or between two farthest MC-60/4A’s of different blocks.
86
Mid-Power Intercom MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
3 MP-S
1 Master station
Sub station
Lineup
N-EA*
NBZ-M*
Surface round frame
Flush square frame
NP-W* Surface mount box for NP-B
AS-3N Sub station
MP-1S
MP-3S
1-call master
3-call master 8d horn speaker locally available
Call button
Power supply PS-1225S PS-1225UL PS-1225
AS-3A
NP-B
Sub station
Flush call plate
m P.103
*Not available in Europe
Features
Wiring
l 1 or 3-call mid-power intercom, 2.5W powered l Incorporates subs either in console, ceiling mount or 8d horn for maximum output l Hands-free reply from sub
MP-1S
150m / 0.8mma
2
MP-1S
8ohm 2
NP-B
1 E
T
Communication network
8ohm BL
+ -
RD
MP-3S
MP-1S MP-1S
MP-3S
8Ω
2x3
AS-3A
2
AS-3N
2
2
8ohm
NP-B 1 E
MP-3S AS-3A
2 E
AS-3N
NP-B
NP-B
BL
★ 3 E
NP-B
T
8d Horn w/talkback reply
NP
+ -
BL
8ohm
RD
l For 8d horn without NP-B, install a 33MFD, 25V NP capacitor on No. line. BL : Blue(2) RD : Red(2) ★NP-25V Capacitor T : PS-1225/S/UL
Unit dimensions MP-1S MP-3S
Specifications (MP-S)
AS-3A
43
83.5
169
177
83.5
Power source Power supply Communication
78
87
NP
11 E
8Ω
MP-3S
148
NP
142
41
Output Output impedance Wiring
74
Distance
12V DC, 1A. PS-1225S, PS-1225UL, PS-1225 Sub calls in w/tone (& LED 20 sec. on MP-3S). Press sub selector and TALK to transmit, and release to listen. 2.5W at 1KHz. 8d 2 parallel wires per sub, non-polarized. *Do not make E wires common. MP-S to sub 100m(0.65mma) 150m(0.8mma)
High-Power Intercom MASTER
SUB
Master station
Sub station
Call button
Lineup NP-W* Surface mount box for NP-B
NP-B Flush call plate
AS-3N Sub station
NBZ-M* Flush square frame for AS-3N
AP-5M 5-call master
AP-10M 10-call master (Photo)
N-EA* Surface round frame for AS-3N
AS-3A
AP-1M
Sub station
1-call master
*Not available in Europe
Features
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
10 AP-M
2
Wiring
l 10 watt-powered paging & communication system l Selective all call to 5 subs l Single or dual-master configuration l 8d or 16d horn speaker with talkback
2 2
NP-B
2
AS-3N
Communication network 7
(1) AP-10M
(1) AP-10M
1 E
NP-B AS-3N
3 E
4 E
4 E
5 E
5 E
C E
10 E
10 E R
C E R
GND
GND
Unit dimensions 140
BL RD
BL 1 E
RD
240
253
AP-5M, AP-10M
1 E
3 E
(1) 8d horn
NP25V 33μF
AP-10M
2 E
AS-3A
114
P.
2 E
NP-B
AP-1M
3P(2P+1)
AP-10M
AS-3A
NP-B
BL : Blue(2). RD : Red(2). 276
196
41 74
180
169 142
Power source Consumption Communication
NP-B 115
AS-3N 83.5
AS-3A
Specifications (AP-M)
15
47.5
70
16
27
Wiring Distance
110~125V, 127V, 230V, 220~240V AC, 50/60Hz. 45W. 6W standby. Sub calls in with tone & LED, 15 sec. Depress selector and use Talk/Listen switch. All call selectively to max. 5 subs. Max. 10W transmit, adjustable. 300mW receive, adjustable. 1 twisted pair per sub, non-polarized 3 pairs (5), masters. AP-M to sub 150m(0.65mma) 230m(0.8mma)
88
Nurse Call MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
80 NHX
1
Master station
*Not available in Europe, Australia, nor New Zealand
Add-on selector
Central control unit
NHR-SP Duty station
NHX-80X Central control unit
NHX-50M 50-call master station
NHX-30G
Zone light
30-call add-on selector Plugs into NHX-50M
NHR-30K 30-call add-on trunk card
NHR-3A-4
Power supply PS-2420S PS-2420UL PS-2420 m P.104 Features l One master, up to 80 sub stations. Single and dual patient stations l Multi-station capability per patient room l Three types of call-ins from patient stations: Routine call, Bathroom call & Cord-out trouble call, identified by tone & blinking LED (w/priority according to urgency and time of call) l NHR-3TS Common Area Call station is used for common area bathroom call or staff call (urgent) l Optional zone light (max. 4)
4-zone call light
Communication network
NHR-4A/A
Duty station NHR-SP NH-2SA/A
NHR-7A
Tone & LED
Communication 1. At NHX-50M master, when called by a bedside sub, either lift handset or press TALK once to establish talk channel. To initiate a call, press the selector button of the sub. At the sub, pretone sounds and TALK is lit green. Corridor and zone lights do not turn on. To silence the tone, press TONE-OFF button. Tone will resume after 90 seconds or when new call is placed. 2. Corridor lamp & Zone 1~4 light turn on with any type of call placed by sub station area. When talk channel is established, two lights will turn off. 3. A call from NHR-3TS is of the same level as Urgent bathroom call. (no verbal communication)
Patient rooms NH-1SA/A
Blinking
NHR-4A/A
• Routine call, Urgent bathroom call or Cord-out trouble call Tone & LED
NHR-4A/A
NH-2SA/A
NHR-7A
Common area restrooms NHR-7A NHX-50M NHX-30G
(up to 3)
NHR-3TS
(max. 4) 1
2
NHR-3A-4 Lights on for any call
NHR-7A 3
4
• Urgent bathroom call
NHR-3TS
• Urgent staff call
89
Duty station
Staff call area NHR-7A
(up to 3)
Corridor lamp
NH-1SA/A
NH-2SA/A
NHR-3TS
NHR-4A/A
Single-jack bedside sub station
Dual-jack bedside sub station
Calling zone light
Corridor lamp w/red & white lamps
NHR-8A
NHR-DP
NHR-7A
NHR-7A
Bedside call switch
Dummy plug
Staff call switch
Bathroom pullcord
Call tone & light annunciation TYPE OF CALL
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Sub station
Wiring TONE
LIGHT
Single chime, every 6 sec. —
Blinking, every 2 sec. ‘CALL’ steadily lit White lamp steadily lit
Routine call At NHX-50M (& at Duty station) At Bedside sub At Corridor lamp
—
NHR-4A/A Sub trunk line (max. 10 subs)
NH-1SA/A 3P
NHR-4A/A
NH-2SA/A
Double blinking, every 1.8 sec.
At Bedside sub
—
‘CALL’ steadily lit
At Corridor lamp
—
Red lamp Blinking
3
3P
NHR-7A
3
NHR-7A 3
3
Single chime, every 0.5 sec.
Blinking fast, every 0.4 sec.
—
‘CALL’ steadily lit
—
White lamp Blinking
3
2
NHR-7A 3P
3
3P 1 5
1
2
1 3
4
5
PS
2
1 3
4
NHR-3TS in common area
Staff call (urgent)
—
Red blinking (2 lamps) White blinking (one lamp)
5m PS PS
2
1 3
5
PS 5
4
2
5 50m
3
4
(max.4)
20m
5P
—
20m
......
NHX-80X CCU
Bathroom call (urgent)
20m
NHR-7A 3 20m
NHR-3TS
Cord-out trouble call
At Corridor lamp
NHR-7A 20m NH-1SA/A
3
3P
At Bedside sub
NHR-7A
3
NHR-4A/A
Single chime, every 2 sec.
At NHX-50M (& at Duty station)
50m up to farthest sub. Max. 100m per block.
3P
Urgent bathroom call or NHR-3TS
NH-1SA/A
3
3
At NHX-50M (& at Duty station)
NH-1SA/A
3
20m NHR-SP
NHX-50M/NHX-30G
PS : PS-2420/S/UL
Line-off trouble at NHX-50M Line-off at bedside sub Line-off at Duty station
Slow buzzer, intermittent Faster buzzer, intermittent
Lit 0.2 sec., every 2 sec. No light
Sub trunk line: 6 wires (3P). 4P with NHR-3A-4 light included. Each zone requires a separate common wire from NHX-80X. Use twisted pairs with an overall shield, low capacitance, 0.65mm dia., solid conductors. (Rated capacitance level of wire: 25pF/30cm or less)
90
Nurse Call
NHX Components
*Not available in Europe, Australia, nor New Zealand
NHX-80X Central control unit
Features
Specifications (NHX-80X)
Controls the NHX-50M and up to 80 sub stations. 1 ~ 8 trunk lines of up to 10 stations per trunk connected inside CCU. (3 pairs, or 4 pairs if zone light is installed). 5 pairs to Master station. Terminates in CCU Zone light (4 in loop), Duty station, and power supplies(2). After installation, the NHX-80X must be initialized. During use, turn power switch off and back on to reset. Install NHR-30K Expansion Trunk Card when NHX-30G is used.
Power Source Power supply Station capacity Calling Communication Call-in priority
Warning tones
Wiring
Unit dimensions NHX-80X
Wiring distance
460
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Central control unit
NHR-30K 30-call add-on trunk card
Mounting 340 98
24V DC, 4A max. 2 pcs PS-2420S, PS-2420UL, PS-2420 50 sub stations (max. 80 with NHX-30G & NHR-30K). Routine call, Urgent bathroom call & Cord-out trouble call. Up to 5 calls can be displayed on NHX-50M. Single and private talk channel. Press-to-talk or handset voice-actuation (1) Cord-out trouble call, (2) Urgent bathroom call and NHR-3TS common area bathroom call or staff call, (3) Routine call. Subs’ call-ins on standby connected according to urgency level and time of call. (1) Line-off trouble at Bedside or NHR-3TS sub & Duty station. (To stop tone on the Duty station, plug in, 2-pin jumper to CN104 in CCU).(2) 90 sec. elapse timer: Call tone goes up to HIGH level.(3) 90 sec. off-hook timer: Steady tone will notify that handset is off-hook. 3 (or 4*) twisted pairs, CCU to Sub trunks 1~8. (*when zone light is installed) 5 twisted pairs, CCU to NHX-50M. 6 wires (parallel), CCU to NHR-SP. 5 wires (parallel), CCU to NHR-3A-4. Use twisted pairs with an overall shield, low capacitance, 0.65mm dia., solid conductors. (Rated capacitance level of wire: 25pF/30cm or less) CCU to Sub (farthest) 50m(0.65mm) Sub trunk line 100m(0.65mm) CCU to NHX-50M 20m(0.65mm) CCU to Duty station 20m(0.65mm) CCU to Zone light 50m(1.0mm) CCU to PS-2420UL 5m(1.0mm) 3-gang wall-mounting. Or inside Electrical Enclosure with secured door (Provide a suitable, non-combustible mounting surface).
Master station Features
NHX-50M 50-call master station
Unit dimensions NHX-50M
210
NHX-30G 210
Extremely compact 50-call desk console. Open voice communication with TALK button, or handset (voice-actuated). When called, simply press TALK or pick up handset to establish channel. Otherwise, press TONEOFF button and go to calling location. To initiate a call, press a selector button first. NHX-30G is a 30-call add-on selector. Plugs itno NHX-50M.
280
94
90
58.5
Specifications (NHX-80X) Wiring
NHX-30G 30-call add-on selector Distance
10-pin plug in connector (to NHX80X). Provided with preset volume controls. Can verify connection of all sub stations. Install within 20m from CCU.
Duty station Features
Specifications (NHX-80X)
Acknowledges any station call with tone and blinking LED. Go to the NHX-50M. Press TONE-OFF and identify the caller at Master station.
Mounting Wiring
Unit dimensions
120
NHR-SP
NHR-SP Duty station 116
91
46
2-gang semi-flush mounting. CN1 (6 pin) to NHX-80X. When NHRSP is installed, unplug Connector from CN104 on NHX-80X.
NH-1SA/A
NH-2SA/A
Single-jack bedside sub station
Dual-jack bedside sub station
Features
Specifications
Bedside station for calling and communication. Used with NHR-8A call cord. When call button is pushed, iCALLj LED is lit red. When master replies, green iTALKj LED is lit. Press CANCEL to reset the call. When NHX-50M calls in, pre-tone sounds and iTALKj LED is lit green. Dummy plug (NHR-DP) Plugs into jack unused on bedside sub stations.
Mounting Wiring
2-gang semi-flush mounting Sub Nos. 1 ~ 10 setting on SW1. CN1 (6 pin) to sub trunk line. CN2 (8 pin) for NHR-7A, NHR-4A/A & zone light.
Unit dimensions
120
NHR-8A NHR-3TS
NHR-3TS 120
NH-1SA/A, NH-2SA/A
Bedside call switch
Calling zone light 116
46
116 28 45
NHR-DP Dummy plug
Bathroom pullcord
NHR-7A Staff call switch
Mechanically locked calling device, used to place an urgent bathroom call from a patient room, common area bathroom or staff call location. Cannot be used alone, and must be used with NH-1SA/A, NH-2SA/A, or with NHR-3TS common area call station. Provides dry closure contact. Master-CALL LED indicates call placed. Ratings 24V DC, 100mA (min. 5mA or more).
Unit dimensions NHR-7A 115
Features
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Bedside sub station
71
10
Specifications Wiring Distance
Single-gang semi-flush mounting. 3 wires to patient station or NHR-3TS.
Corridor lamp When a call is placed, the NHR-4A blinks red or is steadily lit white. Ratings: 24V DC (or more), 200mA max.
Unit dimensions NHR-4A /A 120
Features
70
NHR-4A/A
27
Specifications
Corridor lamp w/red & white lamps
Wiring Distance
Single-gang semi-flush mounting. 3 wires to Bedside sub station.
Zone light
NHR-3A-4 4-zone call light
Unit dimensions NHR-3A-4 46
Zone lamp turns on when any call is placed on the system, indicating which zone has a call placed. Up to 4 zone lights can be installed in one system. Install one PS-2420S, UL for every 2 zone lights. Lamp ratings: 24V DC ~, 200mA.
120
Features
438
92
Nurse Call NHX-80X
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
51 52 53 54 55 56
A NH-1SA/A
NH-1SA/A
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
ZL
ZL
ZL
11 12 13 14 15 16 Z3
Z1
61 62 63 64 65 66
21 22 23 24 25 26
71 72 73 74 75 76
31 32 33 34 35 36 Z4
81 82 83 84 85 86
NH-1SA/A
D
1
2
NHR-3A-4 1
3
2
3
4
OR YL RD GR BL RD
4
OR YL RD GR BL RD
NHR-3A-4
NHR-3A-4
1
1
2
3
2
3
4
OR YL RD GR BL RD
+ ---
+ --G
PS-2420S
WL
WL
RL E
RL E
TC TL E
TC TL E
2 NHR-4A/A RD OG R1 R2
ZL LC
R3 R4 RC
E
PR GY
ZL LC
NHR-7A YL BL GR BL
PS-2420S NHX-50M
DS1 DS2 DS3 DS4 DS5 DS6
A Patient rooms w/a single bedside sub station B Staff call (corridor) C Bathroom call (common area) D Patinent rooms w/multiple bedside sub stations E Corridor lamp NHR-4A/A 1 : Two white lamps 2 : One red lamp NHR-4A 2 is required only when NHR-7A bathroom pullcord is installed in a single and common bathroom.
93
1 2 3 4 5 6
BR OG RD OG
6 (parallel)
NHR-SP
1 2 3 4 5 6
41 42 43 44 45 46
4
OR YL RD GR BL RD
G
NH-1SA/A
Z2
1 NHR-4A/A
NHR-3A-4
NH-1SA/A
S1 S2 S3 S4 S5 S6 PS24
A+ A-
PS24
B+ B-
M1 M2 M3 M4 M5 M6 M7 M8 M9 M10
NHX-30G
M1 M2 M3 M4 M5 M6 M7 M8 M9 M10
PS24: PS-2420S, PS-2420UL, PS-2420 Wire color identifications NHR-3A-4 OR: Orange (Zone 1) YL: Yellow (Zone 2) RD: Red (+) GR: Green (Zone 3) BL: Blue (Zone 4) RD: Red (+) Zone light relay makes contact.
NHR-4A/A BR: Brown OG: Orange RD: Red OG: Orange NHR-7A YL: Yellow BL: Blue GR: Green BL: Blue
NH-1SA/A BR: Brown RD: Red OG: Orange YL: Yellow GR: Green BL: Blue PR: Purple GY: Gray
NHR-3TS BR: Brown RD: Red OG: Orange YL: Yellow GR: Green BL: Blue PR: Purple
C NHR-3TS
NHR-3TS
NHR-7A
1 2 3 4 5 6
WL RL E TC TL E ZL
PR GY
1 2 3 4 5 6 BR RD OG YL GR BL PR
BR OG RD OG YL BL GR BL
NHR-4A/A WH RD
NHR-7A
1 2 3 4 5 6
TC1 TL1
BR RD
E
OG
TC2 TL2
YL GR BL
YL BL GR BL
NHR-7A
ZL
TC1 TL1
BR RD
E
OG
TC2 TL2 ZL
NH-1SA/A
NH-1SA/A
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
WL
WL
WL
WL
RL E
RL E
RL E
RL E
TC TL E
TC TL E
TC TL E
TC TL E
ZL LC
PR GY
ZL LC
PR GY
YL BL GR BL
BL PR
NH-1SA/A
PR GY
YL BL GR BL
YL GR
NH-1SA/A
ZL LC
NHR-7A
YL BL GR BL
YL BL GR BL
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
B NH-1SA/A
ZL LC
Multi-station patient room applications Multiple NH-1SA/A and NH-2SA/A bedside sub stations can be installed within a patient room, observing the following conditions; 1. Max. 6 bedside sub stations may be connected per room for max. 12 calls (when NH-2SA/A stations are used). 2. A corridor lamp inside (NHR-4A) must not be connected with more than 4 bedside sub stations. 3. Due to the above, install two NHR-4A/A corridor lamps when more than 4 sub stations are in one room, i.e. two WHITE lamps used in one NHR-4A/A, and one RED bulb used in the other NHR-4A/A. 4. NH-1SA/A and NH-2SA/A station numbers must be programmed in numerical order and connected to the same subs trunk line. 5. NHR-7A bathroom pullcord is optional.
94
Nurse Call MASTER
SUB
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
120 NEM
1 Master station
Sub station
NEM-10/C
NEM-10A/C
10-call master
10-call master
NEM-20/C
NEM-20A/C
20-call master
20-call master
NA-A Sub station
NA-AN Privacy sub station
NEM-30/C
NEM-30A/C
30-call master
30-call master
NEM-40/C
NEM-40A/C
40-call master
40-call master
Features
Power supply PS-2420S PS-2420UL PS-2420 m P.104 Wiring
l Lamp memory intercom: Sub’s call-in with tone & light l Press-to-talk or handset with voice actuation l Selective or group call of 10 subs l All Call l Pre-tone sounding at sub, when selected l Optional accessories for health care applications l Expand beyond 40 stations with 50-120-call master stations
NA-A/AN
NA-NE
NA-A/AN
2
2
2
2
2 2
NB-L
Communication network 1+n
1+n
2 NBY-1A
(1) 2 (2)
2 NBY-4A
NBY-4A
2 NEM-40A/C (3)
(1) (2)
(2) NB-L
NA-A
NA-A
NA-A
NA-A
(3) NBR-7AS-S
(4)
(5)
(1) All call for instant transmission to all subs (2) Selective call up to 10 subs or individually (3) Subs call-in w/tone & LED staying with corridor light on (4) NBR-7AS-S: Bathroom pullcord in a patient room (5) Multi-substation patient room
95
NAR-2A
l 1 + n = 1 common + no. of Subs
NEM-40A/C
NEM-40A/C
NBR-7AS 2 3
2
NBR-8A
3
NBJ-20(*2)
IER-2
NAR-6A
NBY-4A
NAR-3
Call switching device for NEM-10/C, 20/C m P.98
Call button
Corridor call light
Round corridor light
NBJ-40(*2)
Call extension m P.101
NB-L
NE-JA
Ceiling sub station
Flush sub station
NR-4AS13(*1) B
Call switching device for NEM-30/C, 40/C m P.98
NB-U Music adaptor m P.98
NBJ-20B(*2)
NA-NE Sub station
NA-T/A(*1)
NEW-5
NAR-2A
NBY-1A Metal jack for bedside call switch
Dual master call NBJ-40B(*2) adapto Call switching m P.98 device for NEM-30A/C, 40A/C m P.98
Call reset button
NBR-8A Bedside call switch
Handset sub station
NBR-7AS-S(*1)
NBR-7AS Bathroom pullcord, moisture-resistant
(*1 ) NA-T/A, NBR-7AS-S, NR-4AS13: Not available in Europe, Australia, nor New Zealand
Wiring
Call switching device for NEM-10A/C, 20A/C m P.98
B
(*2) NBJ-20/40, NBJ-20B/40B: Not available in Europe
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Lineup
Wiring
NEM-40A/C
NEM-40A/C E 1 2 3 4 5
9 10
E
A B C D E
NBY-4A
1 2 3 4 5 6 7 8 9 10
NA-NE
NA-A
RD BK GR OG OG/WH BL
NBY-4A
NBR-7AS-S (SOP) BL
N
+ –
(2) NBY-1A
BLx2 BLx2
E
RD BK GR BL OG OG/WH
RD BK GR BL
NBY-1A
NBY-4A
NBR-7AS x2
BLx2 NBY-4A
NAR-2A
11 12 13 14 15 16 17 18 19 20
NBR-7AS
IER-2 S S
RD BK GR BL OG
NAR-2A
NB-L
39 40 1 E
X
BL NAR-2A
NAR-2A
RD BK GR BL OG OG/WH
NBY-4A
BLx2
E 31 32 33 34 35
(1)
NB-L
NBR-8A
Health care application l Up to three NBR-7ASs can be connected in parallel. RD : Red BK : Black GR : Green OG : Orange OG/WH : Orange/White BL : Blue N : PS-2420S, PS-2420UL, PS-2420
PS24
+ —
A B C D E
(3) BL NR-4AS13 (SOP) BL BLx2
A B C D E
A B C D E
A B C D E
(4)
NA-A, NA-AN
NAR-2A
Bathroom pullcord within a patient room (1) NBR-7AS-S: Call-in from NBR-7AS-S cannot be cancelled with NAR-2A Call reset button. Press on upper end of Call button on NBR-7AS-S to release the call. (2) Cut GREEN wire. Multi-substation patient room (3) NR-4AS13: NBY-4A corridor call light may hold up to three NA sub stations. Use NR-4AS13 for more than three NA sub application. (4) Remove the D - E link on each NA sub station. N : PS-2420S, PS-2420UL, PS-2420
96
Nurse Call COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Lineup
IER-2 Call extension m P.101
NEM-60A 60-call master
Unit dimensions
NEM-60A
60-call master
60-call master
NB-U
NEM-70
NEM-70A
70-call master
70-call master
Music adaptor m P.98
NEM-80
NEM-80A
80-call master
80-call master
NEM-90
NEM-90A
90-call master
90-call master
NEM-100
NEM-100A
100-call master
100-call master
NEM-110
NEM-110A
110-call master
110-call master
NEM-120
NEM-120A
120-call master
120-call master
176 140
NEM-40A/C
260
260
746 896 1046 1196
15
47.5
NA-NE
142
340
74
83.5
82
Specifications (NEM) Power source
70
NAR-6A NAR-2A
55
Power supply Communication
83.5
120
115
83.5
NBY-1A
70
43
NE-JA
23
3
10 (2-gang) 94
Output
Wiring Distance
232
83.5
NA-T/A 115
95
*NEM-n/7.A width : Reduce 100mm (handset part) for each sized station. 120
185
220
NBY-4A
68
211
180
169
83.5
NA-A/AN
160
176 140
NEM-50A ~ NEM-120A
446 596
NB-L
97
50-call master
NEM-60
260
140
346 496
116
NEM-50A
50-call master
Unit dimensions
NEM-40/C
70
NEM-50
105
24V DC, 45W max. 2.5W standby (40-call) 24V DC, 180W max. 7.5W standby (120-call) PS-2420S, PS-2420UL, PS-2420 (40-call) Open voice press-to-talk or handset voice actuated. Sub calls in w/tone & LED latching at master. Press TALK button to transmit, release to listen, or lift handset. At sub, pretone and voice when selected. Talk hands-free. Press ALL CALL button to activate all sub stations. 500mW max., adjustable. All Call: 6W, 12W. 24W (120-call) Selectively up to 10 subs w/TALK: 3W 2 wires per sub, non-twisted (1 common + no. Subs) NEM to NA subs 130m(0.65mma) 200m(0.8mma)
Features
NBJ-20* Call switching device
NBJ-40* Call switching device
NBJ-20B* Call switching device
NBJ-40B* Call switching device
*Not available in Europe
l Switches all NA sub wiring from one master to the other to route all call-ins to the master on duty. l NBJ-20 & NBJ-20B are equipped with a rotary switch, and NBJ-40 & NBJ-40B with two rotary switches. l When the rotary switch is put to 1 position, all the sub wiring is connected with Master station(M1). To switch the sub wiring to Master station(M2), put the rotary switch to 2 position.
Wiring NEM-20/C
NEM-20/C
1 2 3 4 ... n E
1 2 3 4 ... n E
1 2 3 4 ... n E M1
1 2 3 4 ... n E M2
M1 : Master station 1. M2 : Master station 2. S : Sub station.
S 1 2 3 4 ... n E M
NA-A, AN, NE, NB-L
NBJ-20 NBJ-20B
(*)Terminal M remains unused. (on NBJ-20B)
Used for NBJ-20 for NEM-10/C & NEM-20/C NBJ-40 for NEM-30/C & NEM-40/C NBJ-20B for NEM-10A/C & NEM-20A/C NBJ-40B for NEM-30A/C & NEM-40A/C
Music adaptor Features l Distributes music to all subs with auto mute while communicating. l When NEM includes NEW-5 adaptor(s), NB-U cannot be used.
Wiring NA-A/AN/NE NB-L
NEM-40A/C 1 2 3 4 5 6 7 8 9 10
Used for NEM-n/C, NEM-nA/C (n = 10 ~ 40)
NB-U
B Y
B Y
A1 V1
A1 V1
A2 V2
A2 V2
A3 V3
A3 V3
A4 V4
A4 V4
E
E
40 E
COMMERCIAL & INSTITUTIONAL APPLICATION SYSTEM
Call switching device
BGM 8Ω 8Ω
l As shown, connect NB-U to 8 Ohm output of Amplifier with twisted pair wires. l Remove jumpers between A1~V1, A2~V2,A3~V3, A4~V4 on master station. l Amplifier requirements: Input: 100mV for rated output. 10W w/8d output or 10W w/4~16d output. l Do not use 1Kd output on the amplifier.
NB-U Music adaptor
Specifications Power source Permitted input Wiring Distance
6V DC, supplied by NEM. 5W. 10W at its peak. 3 wires commom + 2 per 10-call (max.11). NB-U to NEM 10m(0.65mma) 15m(0.8mma) NB-U to Amp. 75m(0.65mma) 115m(0.8mma)
Dual-master call adaptor Features l Common NA subs place a call ringing two NEM masters. l One NEW-5 req’d for every five subs calling both masters. Eight NEW-5 for 40 sub stations, can be powered with one PS-1225S.
NEW-5
Cabling NA-A/AN/NE NA-A
NEM-40A
2xNA
NEW-5 4+1xn
N
T
NEM-40A 4+1xn 36
NA-A/AN/NE 2xNA
N
40
Used for
T : PS-1225/S/UL
NEM-n/C, NEM-nA/C (n=10~40)
Specifications (NEW-5) Power source Power supply Capacity
Dual master call adaptor Communication Wiring Distance
N : PS-2420/S/UL 12V DC PS-1225S, PS-1225UL, PS-1225 5 subs per NEW-5. Max. 8 adaptors for NEM-40(A)/C. Separate channel for ea. master. 2 wires, NEW-5 to sub. NEW-5 to sub 130m(0.65mma) 200m(0.8mma) NEW-5 to NEM 100m(0.65mma) 150m(0.8mma)
98
Accessories Access control
*Available 2nd Quarter 2008
Features Surface mount
AC-10S Vandal resistant access control keypad, surface mount
l Two types of keypads are available. AC-10S: Surface mount type AC-10F: Flush mount type l AC-10S matches JF-DV, color video door station. l Vandal resistant panel, zinc die cast, and tamper proof screws are included. l Two independent relay outputs (N/O or N/C) are available. When same access code is programmed for both #1 and #2, two relays activate simultaneously. l Programmable up to 100 access codes* 4, 5, or 6 digits in length. * #1: up to 60, #2: up to 40 l Keypad lockout: After too many incorrect access codes are attempted. l Anti-tailgate: As soon as the door is closed after access is granted on #1, the door is locked even before programmed output time. Prevent sneak in. l One push door release with external timer connection: While the external timer is on operation, access code is not required. Press “0” key only. Programmable #1 and/or #2. l External output for alarming: When “Lockout” or “Forced entry” occurs, external output is available at #2. l Two LED indicators show the status of the access control system. l Illuminated keypad is easy to read. l Audible key press
Features l Activate door release (relay) By keypad
By request to exit/entry button
Enter ID
Press button Orange
#1 1 4 7 A
2 5 8 0
#1
3 6 9 B
1 4 7 A
#2
Green
#2
2 5 8 0
3 6 9 B
#1
#2
#2
Beep
JF-DV, AC-10S m P.1,3
#1
ACCESSORIES
l Keypad lockout Bleep The keypad is locked out after too many incorrect access codes are attempted.
1 4 7 A
Flush mount
2 5 8 0
3 6 9 B
Programmable l Incorrect access code: 10-99 times l Lockout time: 10-99 seconds Blink keypad 4 times Blink LED (orange) programmed period Sound buzzer approx. 3 seconds
l Anti-tailgate Door sense switch Enter ID for #1 Lock
1 2 3 4 5 6 7 8 9 A 0 B
AC-10F Vandal resistant access control keypad, flush mount
l One push door release with external timer connection During the timer is on operation ON: 9AM-5PM
Power source 12-24V DC power supply 12-24V AC transformer ★
99
Press “O” key 1 4 7 A
2 5 8 0
3 6 9 B
The design and specifications are subject to change without notice for improvement.
Unlock
Door is locked 1 second after door was closed even during relay on-time.
Wiring (1) Relay #1 (Normally open)
(2) Relay #1 (Normally closed) & Relay #2 (Normally open) 300m /1.0mmø #1 Electromagnetic door strike
300m / 1.0mmø #1 Electric door strike
MH
2
2 2
12V-24V AC/DC
V V
SW #1
PB1 PB2 C T
Common #1 Electric door strike
NO1 C1 NC1
M H
Request to exit switch #1
NO2 C2 NC2
Power source
V V
SW #1 SW #2 Common Timer
PB1 PB2 C T
#1 Electromagnetic door strike
Nomally closed
M
NO1 C1 NC1
2 2
12V-24V AC/DC
300m (18V - 24 AC/DC, 0.65 - 1.0mmø)
12V-24V AC/DC
Relay #1 N/O
2 2
door strike
300m (18V - 24 AC/DC, 0.65 - 1.0mmø) Power source
AC-10S
2 M MH2 #2 Electric
AC-10S
Relay #1 N/C
C
M
#2 Electric door strike
H
NO1 C1 NC1 NO2 C2 NC2
12V-24V AC/DC Request to exit switch #1 Request to exit switch #2 Timer
Relay #1 N/C Relay #2 N/O
H : AC transformer C : Power supply
Specifications (AC-10S, AC-10F) 25
33
117
5
Access code
Number: Up to 100 (#1: 60, #2: 40) Code length: From 4, 5, or 6, (0 ~9, A, B) Two conductors Access control ~ Power source: 100m (12V – less than 18V AC/DC, 0.65 – 1.0 mmø) 300m (18V – 24V AC/DC, 0.65 – 1.0 mmø) Access control ~ Request to exit button 300m (0.65 – 1.0 mmø)
45
Wiring Wing distance
Back Box
JF-DV + AC-10S
12 – 24V AC or 12 – 24V DC Max. 100mA Output: 2 Contact rating: 24V AC/DC, 3A (resistive load), 1A (inductive load) Dry contact: Normally open or Normally closed Operating time: From 1 second to 99 seconds
100
125
98
132
AC-10F
55 68.5
AC-10S
Power source Consumption Relay
173
100
27
45
Environment
Weather resistant (IP54 equivalent)
125
5
85
ACCESSORIES
Unit dimensions
98
33
100
Accessories Call extension Features
Wiring
l Announces (chime) call tone only, adjustable l Indoor mounting
KC-1MRD
IER-2
Used for
2
IE series, MK-1GD, MK-2MCD KC-1MRD, KC-1GRD, KB-3MRD NEM-n, NEM-nA, TC-M JA-2MECD, JA-2MCD, JF-1MD, JF-2MED
NP
S S
Unit dimensions
1 E
IER-2 83.5
120
Call extension
29
88
Door release Features
Wiring
l Door release activation, momentary or talk linecontrolled
KC-1MRD LEF-10C
VC-M
– L
L+ L–
Used for
EL-10S Electric door strike
ACCESSORIES
RY-PA Door release relay
Single-family unit DA-1DS/G, C-123L/A IE-1AD(U), IE-1GD(U) IE-2AD(U), IE-8MD(2) TD-H/B (via DE-UR) LEM-1DL LEF, LEF-C (via RY-PA) MYW-P3CB(3) MYW-P3L(3) (via RY-PA) MK series JA-2MECD, JA-2MCD JF-1MD, JF-2MED KC-1MRD, KC-1GRD KB-3MRD Multi-family unit DA-2DS/G, DA-4DS/G GF (5) VC-M (via RY-PA)
EL-10S
EL-10S
YL
L+ L–
BK
RY-PA
H
H
BK : Black(2) YL : Yellow(2)
Specifications (EL-10S) Power source Consumption
12V AC 180mA
Specifications (RY-PA) Power source Relay contact rating
12V DC 110V AC, 1A 24V DC, 1A
Relay Features
Wiring
Intercom station can be signaled by external device via RY-AC/A relay. External device will be activated momentarily as long as the call signal on the intercom is activated.
Used for TD-H/B, TD-Z/A IE-Series IE-8MD, LEF
(1) (2)
PWR
1 E
1 E
–
+ –
T
WH YL RD RY-AC/A BK YL
RY-AC/A
(1) External signaling device, bell, etc. (2) Call receive termimal WH : White RD : Red(+) BK : Black(-) YL : Yellow PWR : Power source
External signaling relay
Specifications (RY-AC/A)
Unit dimensions
Power source
62 104
101
LEF-10 LE-D
41
Contact rating
12V DC, supplied by power supply of system or trunk line. 0.3A, 240V AC 1.0A, 24V DC Bell, buzzer, etc. must be AC operated or DC mechanical type only.
Relay Features
Wiring
Allows integration of a doorbell, etc. to intercom. The device will be activated as long as handset is ringing. When the intercom is picked up, the device will no longer be activated.
MK-DH
(1)
NP
A1 A2
Used for IE chime tone IE-8MD MK-1GD MK-2MCD KC, KB series AT-406 TB-SE(TC-M)
TAR-3
MK-1GD
PWR
A1 A2
WH BL BK
S S
A
+ –
U
TAR-3
(–)
(+)
OG OG
RD
W
(1) Bell, etc. PWR : Power source WH : White BL : Blue BK : Black(-) RD : Red(+) OG : Orange W : PS-0602D, PS-0602C
Unit dimensions
62
External signaling relay
Specifications (TAR-3) 41
104
Power source Contact rating
6V DC, supplied by PS-0602D, PS-0602C 0.3A, 240V AC 1.0A, 24V DC Doorbell or buzzer must be AC operated or DC mechanical type only.
Auxiliary light power control Features
Wiring
KB-3MRD
(1) (2)
MAW-B
WH
bn E
BL
Used for
RD
KB-3MRD, GF-BC(GF)
OG
PWR
BK
ACCESSORIES
MAW-B relay is used for turning on an auxiliary light to spotlight a caller at the entrance. The light is illuminated when the residential call button is pressed, and during visual monitoring mode.
N
+ –
bn = b1~b3
Unit dimensions (1) Porch light, etc. (2) Local switch WH : White BL : Blue RD : Red(+) BK : Black(-) OG : Orange(2)
MAW-B Auxiliary light control relay 62
Specifications (MAW-B)
104
41
Power source Power supply Power consumption Relay contact rating
24V DC PS-2420S, PS-2420UL, PS-2420 of system. 2.5W max. 0.5W standby Dry closure contact for incandescent light for general lighting of less than 100W.
102
Power Supplies 15V AC Unit dimensions PT-1211D 58
Specifications (PT-1211D) 46
Input voltage & Capacity
230V AC, 50/60Hz
Output voltage
15V AC
83
*Manufactured by Sino-American
PT-1211D
Specifications (PT-1211C) 48
77
PT-1211C 60
Input voltage & Capacity
120V AC, 50/60Hz
Output voltage
15V AC *Manufactured by Sino-American
Used for PT-1211C
DA-1MD
6V DC Unit dimensions
Specifications (PS-0602C) Input voltage & Capacity
120V AC, 50/60Hz
Output voltage
6V DC, 0.2A
75
PS-0602D, PS-0602C
Specifications (PS-0602D) 39.5
Used for
Input voltage & Capacity
230V AC, 50/60Hz.
Output voltage
6V DC, 0.2A *Manufactured by Sino-American
C-123L/A, AT-406, LEM, TAR-3
12V DC Unit dimensions
100-240V AC, 50/60Hz 37W/6582VA
PS-1225S, PS-1225UL 52 90
PS-1225S PS-1225UL PS-1225 (without AC cord)
103
Specifications (PS-1225S, PS-1225UL, PS-1225) Input voltage & Capacity
167
POWER SUPPLIES
PS-0602D PS-0602C
51
Used for IE-1AD(U), IE-1GD(U), IE-2AD(U), IE-2A2D(U), IE-8MD, LEM-1DL, LEF, LEF-C, TD-H/B, TD-Z/A, VC-M, MP-S, NEW-5 (NEM), TB-AD10 (TC-M)
Output voltage
12V DC, 2.5A
18V DC Unit dimensions
Used for
PS-1820S 52
90
IE-8MD, JBW-BA, JF-1MD, JF-2MED MK-1GD, MK-2MCD, MY-CU, MYW-P1L(LEF), MYW-P3L(LEF) TC-M, MYW-BA, KC-32EU, RY-3DL
167
Specifications (PS-1820S, PS-1820UL, PS-1820) Input voltage & Capacity
100V-240V AC, 50/60Hz, 45W/75-95VA
Output voltage
18V DC, 2A
PS-1820S PS-1820UL PS-1820 (without AC cord)
24V DC Unit dimensions
Used for JA-2MECD, JA-2MCD, GF-BC, GF-VBC/A, GFW-VBC, MAW-B MYW-BA, YAZ-90-3W, NEM-(A)/C, KC-1MRD, KC-1GRD KB-3MRD, KC-32EU, RY-3DL, MU-100
PS-2410LD
164
Specifications (PS-2410LD) Input voltage & Capacity
220-240V AC, 50/60Hz 35W
Output voltage
24V DC, 1A
RD BK (+) (–)
PS-2410LD PS-2410LC
Specifications (PS-2410LC) Input voltage & Capacity
120V AC, 50/60Hz 35W
Output voltage
24V DC, 1A
PS-2420S, PS-2420UL 52 90
167
Specifications (PS-2420S, PS-2420UL, PS-2420)
PS-2420S PS-2420UL PS-2420
Input voltage & Capacity
100-240V AC, 50/60Hz 60W/100-125VA
Output voltage
24V DC, 2A
POWER SUPPLIES
66
95
RD : Red (+). BK : Black (-).
(without AC cord)
104
Communication Distance The below graph is to assist you in determining the diameter of wires or communication distance required. Example; To obtain the communication distance for IE-1AD(U) system using 0.8 mm dia. wires; 1. On the graph; Draw a line from IE-1AD(U) on point A 7.8, crossing the line B at the point 0.8 to reach a point reading 225.
A
Distance
B
IE-1AD(U) 0.8 28 225 (m)
COMMUNICATION DISTANCE CALCULATION GRAPH SYSTEM & MODELS TB-AD1, AD10 [TC-M] C-123L/A
A
IE-1GD(U) [IEH-1CD] IE-2AD(U) [IEH-1CD] IE-2A2D(U) [IEH-1C2D]
COMMUNICATION DISTANCE ...m
FIXED NUMBER FOR DISTANCE BY ITEM
2,000
MP-1S, MP-3S 3.4 NEM-nA/C, NEM-n/C
3.9
5.2
COMMUNICATION DISTANCE
TCS-MH IE-1AD(U) [IF-DA] IE-1GD(U) [IF-DA] IE-2AD(U) [IF-DA], IE-2A2DU DE-UR [IF-DA] AP-1M/A, AP-5M/A, AP-10M/A
6.8 7.8
10.4
B
DIAMETER mm 1.6
1,000 900 800
1.4
700
1.2
600
1.0
500
0.8
LEM-1, LEM-3 LEF-3, LEF-5 , LEF-10 LEF-10S LEF-3C, LEF-5C, LEF-10C
400 17.4 0.65 20.9 26.2
300 0.5 225 200
34.0 36.7
VC-nM, VCH [VC-K] AT-206 [AT-306x3] TC-M [TB-SE]
100 MC-60/4A
90
TD-1H, TD-3H, TD-6H TD-12H, TD-24H TD-6Z, TD-12Z
80
AT-406
50
70 60
40
30
20
NOTES; IE-1AD(U) [IF-DA] shows distance between IE-1AD(U) and IF-DA or other IE door station. Video Intercoms are not included in the graph.
105
Compatibility of video intercom system Hands-free color video intercom
✓: Compatible Blank: Not Compatible Existing model
Door station Sub station
Discon. model
Audio door station
JA-DAC JF-DA AX-DV JA-D JA-DGC JF-DV AX-DV-P JF-DVF AX-DVF AX-DVF-P
Master station
Existing model
Video door station
JA-2MECD JA-2MCD JF-1MD JF-2MED AX-8MV JB-2MED JB-2MD
✓ ✓
JF-D
Sub master station
✓ ✓ ✓
✓
✓ ✓
Sub station
AX-DM JA-2HCD JA-2SD JF-2HD JF-2SD JF-1FD JF-1SD JBW-BA JB-DA JB-2HD (audio) (audio) JB-DV (audio) JB-DVF
✓ ✓
✓ ✓
Discontinued model Long distance Video door Sub master adaptor station station
✓ ✓ ✓
✓
✓ ✓
✓
✓
✓ ✓ ✓ ✓
✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
AX-8MV is required a central exchange unit.
Color video intercom ✓: Compatible Blank: Not Compatible Door station Sub station Adaptor
Existing model Sub master station
Video door station KB-DAR
KC-DAR
KB-3HRD
KB-3SD (audio)
✓
✓
Master station KB-3MRD Existing KC-1MRD model KC-1GRD Discon. KA-1MD model KA-1MRD
✓
Discontinued model Long distance Picture adaptor memory
✓ ✓
KC-1HRD
KC-1SD (audio)
✓
✓
JBW-BA
KC-32EU
✓ ✓
✓ ✓ ✓
Video door station
Sub station
KA-DA
MK-1SD/B (audio)
KA-DAR
✓ ✓
✓ ✓
Discontinued model Long Door station Picture Audio door distance Video door station Sub master station memory adaptor Video door station station Sub station Adaptor MK-DV MK-DH MK-DAC MK-2DA MK-D MK-1HD MK-2SD MK-2HCD KC-32EU MYW-BA MY-DA MY-DC, /A MY-DS MK-DA MK-DS MK-DS/B MK-DVF
Master station
✓ ✓ Existing MK-1GD ✓ model MK-2MCD MY-1CD Discon. MY-2CD model MK-1MD MK-1MD/A *Pan tilt feature does not work.
MK-DGC MK-2DG MK-DBC
(audio)
✓ ✓ ✓ ✓ ✓* ✓*
✓
✓ ✓
✓
MY-DB MY-DG, /A MY-CB MY-CA MY-EA MY-FA
✓ ✓ ✓ ✓
✓
✓ ✓
✓
B & W separate monitor and Door adaptor
✓ ✓ ✓ ✓ ✓ ✓
✓* ✓* ✓ ✓
MY-CU
Existing MYW-P1L model
MYW-P3L MY-U Discon. model MYW-P3B MYW-P3CB
✓ ✓ ✓ ✓* ✓* ✓
*Pan tilt feature does not work.
Video door station MK-DAC MK-DGC MK-DBC
✓ ✓ ✓ ✓* ✓ ✓
✓* ✓* ✓ ✓
✓* ✓* ✓ ✓
✓* ✓* ✓ ✓
✓ ✓
✓: Compatible Blank: Not Compatible Discontinued model
Existing model Door station Sub monitor Sub station Adaptor MYH-CU MYH-CUB Monitor Door adaptor
✓ ✓ ✓* ✓*
MK-DS/A
MK-DV MK-DVF
Long distance adaptor
Sub monitor
MYW-BA
MYH-U
✓ ✓ ✓ ✓
Compatibility of video intercom system
✓: Compatible Blank: Not Compatible Existing model
B & W video intercom
Video door station MY-DA MY-DB MY-CB
✓*
✓*
✓ ✓ ✓
✓ ✓ ✓
MY-DC, /A MY-DG, /A MY-CA MY-EA MY-FA
✓ ✓ ✓ ✓* ✓* ✓
MY-DS
✓* ✓* ✓* ✓ ✓ ✓
MK-DS/B
✓* ✓ ✓ ✓
106
INDEX PAGE A AC-10F ............................................... 99 AC-10S ...............................................99 AI-900AF ............................................78 AI-900AL ............................................78 AI-900CO............................................78 AI-900DI .............................................78 AI-900MF............................................78 AI-900MS ...........................................78 AI-900RS ............................................78 AI-900TI ............................................. 78 AI-910DI............................................. 78 AI-MS900 ........................................... 77 AI-PN100B..........................................78 AI-PU200 ........................................... 78 AI-RS150 ........................................... 77 AI-RS160 ........................................... 77 AI-RS170 ........................................... 77 AI-RS180 ...........................................77 AI-YC303 ............................................78 AP-10M .............................................. 88 AP-1M ................................................ 88 AP-5M................................................. 88 AS-3A ................................................ 87 AS-3N ................................................ 87 AT-306 ............................................... 66 AT-406 ...............................................66 AT-406B/A ..........................................66 AT-406P.............................................. 66 AX-084C ........................................ 15,71 AX-16SW....................................... 16,71 AX-248C ........................................ 15,71 AX-320C ........................................ 15,71 AX-8M ........................................... 16,71 AX-8MV ......................................... 16,71 AX-DM .....................................15,30,72 AX-DV............................................ 15,72 AX-DVF.......................................... 15,72 AX-DVF-P....................................... 15,72 AX-DV-P......................................... 15,72 PAGE B BG-10C............................................... 65 PAGE C C-123L/A ............................................ 24 C-D ..................................................... 24 C-ML/A .............................................. 24
INDEX
D PAGE DA-1AG .............................................. 23 DA-1AS .............................................. 23 DA-1MD ........................................ 23,56 DA-2DG .............................................. 56 DA-2DS ............................................. 56 DA-4DG .............................................. ......................................... 56 DA-4DS .............................................. 56 DAR-1 ........................................... 23,56 DAW-P........................................... 23,56 DE-UR ........................................... 67,69 PAGE E EL-10S ............................................. 101 PAGE G GF-10K .......................................... 35,51 GF-10KP......................................... 35,51 GF-1D ................................................. 53 GF-1DK............................................... 53 GF-1MD.............................................. 53
107
*2
*2 *2 *2
*1
GF-1MDK............................................ 53 GF-1P ............................................35,51 GF-2B ............................................35,52 GF-2F ............................................35,52 GF-2P ............................................35,51 GF-3B ............................................35,52 GF-3F ............................................35,52 GF-3P ............................................35,51 GF-4P ............................................35,51 GF-4Z ................................................. 54 GF-6GX24-2 ....................................... 49 GF-AD ................................................. 51 GF-AP ............................................35,51 GF-BC ................................................. 54 GF-BP ............................................35,51 GF-DA ................................................ 51 GF-DP ................................................. 51 GF-GD-TS ........................................... 49 GF-GMK.............................................. 49 GF-GTX .............................................. 50 GF-MK ................................................ 53 GF-nH (n=102, 202, 103, 203, 303) ........... 36,52 GF-nHB (n=102, 202, 103, 203, 303) ......... 36,52 GF-NS ................................................ 51 GF-NSP.......................................... 35,51 GF-SW ................................................ 51 GF-VA ................................................. 51 GF-VBC ............................................... 54 GF-VP............................................. 35,51 GFW-LD.............................................. 55 GFW-S ........................................... 39,53 GFW-VBC ........................................... 55 GH-10K .............................................. 35 GH-1AD .............................................. 38 GH-1KD .............................................. 38 GH-1KDS ............................................ 38 GH-1MD ............................................. 38 GH-4Z................................................. 39 GH-AD ................................................ 35 GH-BC ................................................ 39 GH-BCX ............................................. 40 GH-CCTV ............................................ 42 GH-DA ................................................ 35 GH-DP ................................................ 35 GH-HS ................................................ 38 GH-MK ............................................... 39 GH-NS ................................................ 35 GH-RY ................................................ 40 GH-SW ............................................... 35 GH-VA ................................................ 35 GH-VBC .............................................. 39 GH-VBX .............................................. 40 GHW-LC ............................................. 41 PAGE I IAI-100 ............................................... 80 IAX-100 .............................................. 80 IE-1AD(U)........................................... 26 IE-1GD(U) .......................................... 27 IE-2A2DU ........................................... 28 IE-2AD(U)........................................... 28 IE-8HD................................................ 29 IE-8MD ............................................... 29 IE-DC .................................................. 30 IE-DL1 ................................................ 30 IE-DL2................................................ 30 IE-DL3 ................................................ 30 IE-FY ................................................. 30 IEH-1C2D ........................................... 28 IEH-1CD ........................................ 27,28
IE-JA ..................................................30 IER-2 ............................................... 101 IF-DA .................................................30 IME-100 .............................................79 IME-150 .............................................80 IMU-100 .............................................79 ISE-100 ..............................................80 PAGE J JA-2HCD ...............................................8 JA-2MCD ..............................................7 JA-2MECD ............................................7 JA-2SD .................................................8 JA-D .....................................................7 JA-DAC .................................................7 JA-DGC ................................................7 JBW-BA ..............................................21 JBW-D .............................................. 2,4 JDW-C ..................................................7 JF-1FD ..................................................2 JF-1MD ................................................1 JF-1SD .................................................2 JF-2HD .................................................4 JF-2MED .............................................. 3 JF-2SD ................................................. 4 JF-D...................................................... 3 JF-DA ............................................... 1,3 JF-DV ............................................... 1,3 JF-DVF ............................................. 1,3 JFS-1AD ............................................... 2 JFS-1ADF ............................................. 2 JFS-1ADV ............................................. 2 JFS-2AED ............................................ 4 JFS-2AEDF ........................................... 4 JFS-2AEDV .......................................... 4
K PAGE KA-DGR PANEL ...................................10 KAW-D................................................ 22 KB-3HRD ............................................14 KB-3MRD ............................................13 KB-3SD ...............................................14 KB-DAR ..............................................13 KC-1GRD ............................................11 KC-1HRD ........................................... 12 KC-1MRD ........................................... 9 *1 KC-1SD .............................................. 12 KC-32EU............................................. 21 KC-DAR .......................................... 9,11 KCS-1ARD .......................................... 10 L
*1 *1 *1 *1
*2
PAGE LE-A ......................................... 60,62,65 LE-A3 ............................................ 62,65 LE-AN ....................................... 60,62,65 LE-AN3 .......................................... 62,65 LE-B .............................................. 63,65 LE-BN ............................................ 63,65 LE-C .............................................. 63,65 LE-CN ........................................... 63,65 LE-D .................................... 60,62,63,65 LE-DA ....................................... 60,62,65 LE-DL ................................................. 65 LEF-10 ................................................ 61 LEF-10C ........................................ 20,63 LEF-10S ............................................. 61 LEF-10W ............................................ 61 LEF-1C .......................................... 63,65 LEF-20(S) ........................................... 62 LEF-3 ................................................. 61
*2 LEF-30(S) ....................................62 LEF-3C .........................................63 *2 LEF-40(S) ....................................62 LEF-5 ...........................................61 LEF-5C .........................................63 LEF-5W ........................................61 LEM-1 ..........................................60 LEM-1DL .....................................59 LEM-3 ..........................................60 LEW-10 ........................................62 LEW-10S .....................................62 LEW-5 .........................................62
M
PAGE MAW-B ...................................... 102 *1 MC-60/4A ....................................86 *2 MC-60/4B ....................................86 *1 MC-A/A ........................................86 MCW-S ........................................22 MK-1GD .......................................17 MK-1HD .......................................17 MK-2DA .......................................22 MK-2DG .......................................22 MK-2DG PANEL ...........................22 MK-2HCD ....................................18 MK-2MCD ....................................18 MK-2SD ..................................17,18 *1 MK-D ...........................................18 MK-DAC ......................................18 MK-DBC ......................................18 MK-DGC ......................................18 MK-DH....................................17,18 MK-DV .........................................17 MK-DVF .......................................17 MKS-1GD ....................................17 MKS-1GDV ..................................17 MKS-1GDVF ................................ 17 MKW-P ........................................17 MKW-R ........................................18 MP-1S .........................................87 MP-3S .........................................87 *1 MY-CU .........................................19 *1 MYH-CU .......................19,64,69,85 *1 MYH-CUB ....................................20 MYW-BA .....................................22 *1 MYW-P1L ...............................20,64 *1 MYW-P3L ...............................20,64
P
PAGE PD-1................................................... 68 PD-2................................................... 68 PS-0602C...........................................103 PS-0602D ..........................................103 PS-1225............................................103 PS-1225S .........................................103 PS-1225UL .......................................103 PS-1820 .............................................104 PS-1820S ..........................................104 PS-1820UL .......................................104 PS-2410LC .......................................104 PS-2410LD .......................................104 PS-2420............................................104 PS-2420S .........................................104 PS-2420UL .......................................104 PT-1211C ..........................................103 PT-1211D ..........................................103
*1 TB-ADD ..............................................84 TB-ADM10..........................................85 TB-SE .................................................83 TC-10M ..............................................83 *1 TC-10MD ............................................84 TC-20G ...............................................83 TC-20M ..............................................83 TC-40G ...............................................83 TC-40GS ............................................83 TC-DC .................................................25 TC-MH ................................................25 TCS-MH .............................................25 TD-12H/B ........................................... 68 TD-12Z/A ........................................... 68 TD-1H/B .............................................67 TD-24H/B ........................................... 68 TD-3H/B ............................................. 67 TD-6H/B ............................................. 67 TD-6Z/A ............................................. 68 TDW-1/A ............................................ 68 TDW-12/A .......................................... 68 TDW-24/A .......................................... 68 TDW-3/A ............................................ 68 TDW-6/A.............................................68
V
PAGE VC-0M ................................................ 57 VC-10M .............................................. 57 VC-1M ................................................ 57 VC-26MT ............................................ 58 VC-26MY ............................................ 58 VC-2M ................................................ 57 VC-42MY ............................................ 58 VC-4M ................................................ 57 VC-58MT ............................................ 58 VC-6M ................................................ 57 VC-8M ................................................ 57 VC-BBX .............................................. 58 VCH-16 .............................................. 57 VCH-8 ................................................ 57 VC-K .................................................. 57 *2 VGX-D-YBOX ..................................... 49
W
PAGE W-DIN11 ....................................... 40,55
Y
PAGE YAW-RB ............................................. 70 YAZ-90-3W......................................... 70
*1 Not available in Europe *2 Not available in Europe, Australia, nor New Zealand
INDEX
PAGE N NA-A .......................................81,95 NA-AN.....................................81,95 NA-NE .....................................81,96 NAR-2A .......................................96 NAR-3 ..........................................96 NAR-6A ..................................82,96 *2 NA-T/A ...................................82,96 NBJ-20 ........................................98 NBJ-20B ......................................98 NBJ-40 ........................................98 NBJ-40B .................................... 98 NB-L ...................................... 81,96 NBR-7AS ............................... 82,96 *2 NBR-7AS-S ..................................96 NBR-8A .......................................96 NB-U ............................................98 NBY-1A ........................................96 NBY-4A ........................................96 *1 NBZ-M .........................................87 *1 N-EA ............................................87 NE-JA .................................... 82,96
NEM-10/C ..................................... 81,95 NEM-100 ....................................... 82,97 NEM-100A .................................... 82,97 NEM-10A/C ................................... 81,95 NEM-110 ....................................... 82,97 NEM-110A .................................... 82,97 NEM-120 ....................................... 82,97 NEM-120A .................................... 82,97 NEM-20/C ..................................... 81,95 NEM-20A/C ................................... 81,95 NEM-30/C...................................... 81,95 NEM-30A/C ................................... 81,95 NEM-40/C...................................... 81,95 NEM-40A/C ................................... 81,95 NEM-50 ......................................... 82,97 NEM-50A .......................................82,97 NEM-60 .........................................82,97 NEM-60A .......................................82,97 NEM-70 .........................................82,97 NEM-70A .......................................82,97 NEM-80 .........................................82,97 NEM-80A ......................................82,97 NEM-90 .........................................82,97 NEM-90A ......................................82,97 NEW-5................................................ 98 *2 NH-1SA/A .......................................... 92 *2 NH-2SA/A .......................................... 92 *2 NHR-30K ........................................... 91 *2 NHR-3A-4 .......................................... 92 *2 NHR-3TS ........................................... 92 *2 NHR-4A/A .......................................... 92 *2 NHR-7A ............................................. 92 *2 NHR-8A ............................................. 92 *2 NHR-DP ............................................. 92 *2 NHR-SP ............................................. 91 *2 NHX-30G ........................................... 91 *2 NHX-50M ........................................... 91 *2 NHX-80X ........................................... 91 NP-B .................................................. 87 *1 NP-W ................................................. 87 *2 NR-4AS13 ......................................... 96
R
PAGE RY-3DL .............................................. 21 RY-AC/A ...........................................101 RY-PA ...............................................101
T
PAGE TAR-3 ...............................................102 TB-AD1 .............................................. 84 TB-AD10 .............................................84
108