Data and test specimen: Report No. IES/ABONI/PV-18-03 Test Specimen Water Treatment Plant 01 No. of Vessel 02 Material C/S Manuf. Year N/A Allowable T Min. -10° C
Date Manufacturer Capacity Working Pressure Test Pressure Allowable T. Max
15-08-2018 N/A N/A 4 BAR N/A +50° C
B. Test Data Sheet and Evaluation: Degree
X mm
A mm
B mm
C mm
Y mm
0®
36.2
26.3
27.4
26.9
30.8
90®
35.1
27.0
27.8
27.5
30.9
180®
35.2
26.9
28.1
27.3
30.6
270®
35.1
28.0
26.3
27.9
30.2
Inspection Date:-15/08/2018 0® (East Side)90® North Side180®West Side270®South Side
X A
X
X
X
A
A
A
B
B
B
B
C
C
C
C
Y
Y
Y
Y
Fig: Pressure Vessel (Air Receiver Tank) Page 1 of 1
TESTED BY:
Aboni Witness
IES AUTHORITY approved
Name: Md. Amit Hasan ASNT Level –II (UT, RT, MT, PT,VT)
Name: Aboni – Mr. Md. Jahid , Deputy Manager -MTS
Signature:
Signature:
Name: Akik Ahmed Chowdhury API-510, 570, 580 (Pressure Vessel Inspector ) Signature:
Date: 15/08/2015 Date: 15/08/2018 TEST CARRIED OUT AS PER CODE & STANDARD OF API Standard 1104