West Virginia 2003 Cleanup Standards for Hydrocarbon Contaminated Groundwater Product Gasoline
Diesel
Parameter/ Constituent Benzene Toluene Ethylbenzene Xylenes TPH*
Lab Test Protocol & Number EPA 8021 EPA 8021 EPA 8021 EPA 8021 EPA 8015
Benzene Toluene Ethylbenzene Xylenes TPH*
EPA 8021 EPA 8021 EPA 8021 EPA 8021 Modified EPA 8015, GRO & DRO
Detection Level Notification Level
Action Level
Cleanup Level
1µg/L 1µg/L 1µg/L 1µg/L 0.5mg/L
any amount any amount any amount any amount any amount
5µg/L 1000µg/L 700µg/L 10,000µg/L
5µg/L 1000µg/L 700µg/L 10,000µg/L site specific
1µg/L 1µg/L 1µg/L 1µg/L 0.5mg/L
any amount any amount any amount any amount any amount
5µg/L 1000µg/L 700µg/L 10,000µg/L
5µg/L 1000µg/L 700µg/L 10,000µg/L site specific
Note: Some leaking underground storage tank sites may qualify for West Virginia's voluntary cleanup program, which utilizes Risk Based Corrective Action (RBCA). * As of Sept. 2003. New TPH standards are currently being changed and will be official by the end of 2003. Contact: Mike Sutphin, West Virginia Department of Environmental Protection, 304-558-2508 E-mail:
[email protected]
Copyright © 2009 Association for Environmental Health and Sciences Foundation, Inc. 150 Fearing Street · Amherst, MA 01002 Phone: 413.549.5170 Fax: 413.549.0579 E-mail:
[email protected]
West Virginia 2003 Cleanup Standards for Hydrocarbon Contaminated Soil Product Gasoline
Diesel
Parameter/ Constituent Benzene Toluene Ethylbenzene Xylenes TPH**
Lab Test Protocol & Number
Notification Level Action Level
Cleanup Level
EPA 8021 EPA 8021 EPA 8021 EPA 8021 Modified EPA 8015 *
any amount any amount any amount any amount
50µg/kg total BTEX: 10mg/kg total BTEX: 10mg/kg total BTEX: 10mg/kg 50mg/kg
site specific site specific site specific site specific site specific
Benzene Toluene Ethylbenzene Xylenes TPH **
EPA 8021 EPA 8021 EPA 8021 EPA 8021 Modified EPA 8015 *
any amount any amount any amount any amount
50µg/kg total BTEX: 10mg/kg total BTEX: 10mg/kg total BTEX: 10mg/kg 100mg/kg
site specific site specific site specific site specific site specific
* Report GRO and DRO separately ** As of Sept. 2003. New TPH standards are currently being changed and will be official by the end of 2003 .Note: Some leaking underground storage tank sites may qualify for West Virginia's voluntary cleanup program, which utilizes Risk Based Corrective Action (RBCA). Contact: Mike Sutphin, West Virginia Department of Environmental Protection, 304-465-1911 E-mail:
[email protected]
Copyright © 2009 Association for Environmental Health and Sciences Foundation, Inc. 150 Fearing Street · Amherst, MA 01002 Phone: 413.549.5170 Fax: 413.549.0579 E-mail:
[email protected]