Oklahoma 2003 Cleanup Standards for Hydrocarbon Contaminated Groundwater Product
Parameter/ Constituent
Gasoline, Diesel and Kerosene
TPH
Lab Test Protocol & Number* EPA 8015
Detection Level
Benzene
EPA 8015
1mg/L
Toluene
EPA 8015
1mg/L
Ethylbenzene
EPA 8015
1mg/L
Xylenes
EPA 8020
1mg/L
1mg/L
Notification Level
any amount above Action Level any amount above Action Level any amount above Action Level any amount above Action Level any amount above Action Level
Action Level
> 2mg/L > 0.005mg/L > 1.0mg/L > 0.7mg/L > 10.0mg/L
Cleanup Level
site specific RBCA standards site specific RBCA standards site specific RBCA standards site specific RBCA standards site specific RBCA standards
Note: Oklahoma uses a Risk Analysis in determining cleanup standards on a site-by-site basis. * Whatever method is specified must be able to detect the most stringent cleanup levels. EPA Method 418.1 is not accepted testing method for TPH. Contact: Dick Oppel, Oklahoma Corporation Commission, Underground Storage Tank Program, 405522-5264
Copyright © 2009 Association for Environmental Health and Sciences Foundation, Inc. 150 Fearing Street · Amherst, MA 01002 Phone: 413.549.5170 Fax: 413.549.0579 E-mail:
[email protected]
Oklahoma 2003 Cleanup Standards for Hydrocarbon Contaminated Soil Product
Parameter/ Constituent
Gasoline, Diesel TPH and Kerosene Benzene
Lab Test Protocol & Number* EPA 8015
Detection Level 1mg/kg
EPA 8020
1mg/kg
Toluene
EPA 8020
1mg/kg
Ethylebenzene
EPA 8020
1mg/kg
Xylenes
EPA 8020
1mg/kg
Notification Level
any amount above action level any amount above action level any amount above action level any amount above action level any amount above action level
Action Level
Cleanup Level
>50mg/kg >0.5mg/kg >40mg/kg >15mg/kg >200mg/kg
site specific RBCA standards site specific RBCA standards site specific RBCA standards site specific RBCA standards site specific RBCA standards
Note: Oklahoma uses a Risk Analysis in determining cleanup standards on a site-by-site basis. * Whatever method is specified must be able to detect the most stringent cleanup levels. EPA Method 418.1 is not accepted testing method for TPH. Contact: Dick Oppel, Oklahoma Corporation Commission, Underground Storage Tank Program, 405522-5264
Copyright © 2009 Association for Environmental Health and Sciences Foundation, Inc. 150 Fearing Street · Amherst, MA 01002 Phone: 413.549.5170 Fax: 413.549.0579 E-mail:
[email protected]