Water-level Indicator Simple, two-wire, remote monitoring unit Three-LED level display, 9V battery powered Circuit diagram:
Parts: R1,R2,R10-R12___15K R3,R4____________1K R5_____________100R R6______________47K R7,R8,R13________3K3 R9,R14,R15_______2K7
1/4W 1/4W 1/4W 1/4W 1/4W 1/4W
Resistors Resistors Resistor Resistor Resistors Resistors
C1_____________470nF
63V Polyester or Ceramic Capacitor
D1_______________3mm D2_______________3mm D3_______________3mm
Green LED Yellow LED Red LED
Q1_____________BC547
45V 100mA NPN Transistor
IC1_____________4012 IC2____________LM393
Dual 4 input NAND gate IC Dual Comparator IC
J1,J2____________Two ways output sockets P1______________SPST pushbutton B1________________9V
PP3 Battery
Clip for PP3 Battery Two steel rods of appropriate length
Comments: The whole project was developed on a friend's request. Its purpose was to remotely monitor the water-level in a metal tank located in the attic by means of a very simple control unit placed in the kitchen, some floors below. Mains requirements were: • • • • •
No separate supply for the remote circuit Main and remote units connected by a thin two-wire cable Simple LED display for the main unit Battery operation to avoid problems related to mains supply and water proximity As the circuit was battery operated a low current consumption was obviously welcomed
The very small remote unit is placed near the tank and measures the water level in three ranges by means of two steel rods. Each range will cover one third of the tank capacity: • • •
Almost empty - signaled by means of a red LED (D3) in the control unit display About half-level - signaled by means of a yellow LED (D2) in the control unit display Almost full - signaled by means of a green LED (D1) in the control unit display
Circuit operation: When the water-level is below the steel rods, no contact is occurring from the metal can and the rods, which are supported by a small insulated (wooden) board. The small circuit built around IC1 draws no current and therefore no voltage drop is generated across R5. IC2A, IC2B and Q1 are wired as a window comparator and, as there is zero voltage at input pins #2 and #5, D3 will illuminate. When the water comes in contact with the first rod, pin #13 of IC1 will go high, as its input pins #9 to #12 were shorted to negative by means of the water contact. Therefore, R4 will be connected across the full supply voltage and the remote circuit will draw a current of about 9mA. This current will cause a voltage drop of about 0.9V across R5 and the window comparator will detect this voltage and will change its state, switching off D3 and illuminating D2. When the water will reach the second rod, also pin #1 of IC1 will go high for the same reason explained above. Now either R3 and R4 will be connected across the full supply
voltage and the total current drawing of the remote circuit will be about 18mA. The voltage drop across R5 will be now about 1.8V and the window comparator will switch off D2 and will drive D1. The battery will last very long because the circuit will be mostly in the off state. Current is needed only for a few seconds when P1 is pushed to check the water-level and one of the LEDs illuminates. Notes: • • •
•
•
The two steel rods must be supported by a small insulated (wooden) board IC1 and R1-R4 are mounted on a small board placed near or on the steel rods support The two-wire cable connecting the remote circuit board to the main control board, i.e. J1 to J2, can be of any size and type (preferably thin for obvious reasons). It can be very long, if necessary. The circuit can be used also with non-metal tanks, provided a third steel rod having the height of the tank will be added and connected to pin #7 of IC1, R3, R4 and J1. The 4012 chip was chosen because it contains two gates and was at hand, but you can use two of the gates contained into 4001, 4011, 4093, 4049, 4069 etc. chips, provided all inputs of each gate are tied together and all inputs of unused gates are connected to the positive rail, leaving output pins open.
Having Questions?