Salwico Fire Detection System ISOLATOR-A Intrinsically Safe Isolator with enclosure for Addressable IS Loop Units IP55, Max 20 loop units/isol.
N1790
ISOLATOR-A is an IS isolator intended for use together with Salwico intrinsically safe addressable detectors and manual call points. It contains an IS-isolator and a LISA-2 connection board. ISOLATOR-A is located in a non-hazardous area (safe area) and forming the interface to IS detectors and other IS line units. To each addressable detector loop a maximum of five ISOLATOR-A units can be connected, each of them accommodating up to 20 IS line units. ISOLATOR-A does not need a separate power supply or earth connection. It is powered directly from the fire alarm panel via the loop cable, which means that no extra cables are needed. The cable glands shall be mounted acc. to the dimension drawing on page two. This will guarantee the minimum required distance (50mm) between the intrinsic safe and the non-intrinsic safe conductors.
NS-AOHS-IS Analogue Addressable Intrinsically Safe Optical Smoke/Heat
N11250
NS-AOHS-IS is an intrinsically safe analogue addressable multi sensor detector for Salwico fire alarm systems. It has two separate analogue sensor elements. One optical for smoke detection and one heat-sensing element for heat detection. Alarm condition is indicated on the detector via a red LED. The LED is lit until the alarm has been reset on the control panel. The address is set with a DIP switch, which is mounted on the backside of the detector. NS-AOHS-IS is connected to the detector loop via the ISOLATOR-A, part. no. N1790. Up to 20 addressable IS units can be connected to one ISOLATOR-A. It is not possible to connect any remote LED indicator to NS-AOHS-IS.
EVC-PY-IS Conventional intrinsically Safe Optical Smoke Detector Salwico EVC-PY-IS is an intrinsically safe Evolution conventional optical smoke detector. The detector is equipped with an optical sensor with improved sensitivity to black smoke. The detector is designed for use in areas with high explosion risk. It is connected to the fire alarm system via an intrinsically safe interface. Salwico EVC-PY-IS must not be separated from the base when energized. To avoid the possible risk of electrostatic charge, the unit must not be cleaned with solvents or charged by rubbing.
N1144
HC100/IS Intrinsically Safe Conventional Heat (57°DegC) Detector The HC100 A2 is an intrinsically safe conventional heat detector for use with all Salwico Fire Alarm Systems. The detector is designed for use in areas with high explosion risk. It is connected via an intrinsically safe interface. The heat sensing element is of thermistor type with a short response time to changes in the ambient temperature. Alarms are optically indicated until they are reset on the central.