Tehran Structural Engineering Association Design Guide

  • December 2019
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Tehran Structural Engineering Association Design Guide as PDF for free.

More details

  • Words: 11,771
  • Pages: 37
‫`‬

‫»د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه«‬

‫دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬ ‫آﺑﺎن ﻣﺎه ‪1387‬‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪1 :‬‬

‫ﻓﻬﺮﺳﺖ ﻣﻨﺪرﺟﺎت‬ ‫‪-1‬‬

‫ﻣﻘﺪﻣﻪ ‪2 .........................................................................................................‬‬

‫‪-2‬‬

‫ﻣﺪارك ﻻزم‪3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . .‬‬

‫‪-3‬‬

‫ﻣﻮارد ﻛﻠﻲ درﺑﺎره ﻧﻘﺸﻪ ﻫﺎي ﺷﺎﻟﻮده ‪5 .................................................................‬‬

‫‪-4‬‬

‫ﻣﻮارد ﻋﻤﻮﻣﻲ در ﻧﻘﺸﻪ ﻫﺎي ﺳﺎزه‪7 .....................................................................‬‬

‫‪-5‬‬

‫ﻧﻜﺎت ﺣﺎﺋﺰ اﻫﻤﻴﺖ در ﺟﺰﺋﻴﺎت ﺳﺎزه ﻫﺎي ﺑﺘﻨﻲ ‪13 ....................................................‬‬

‫‪-6‬‬

‫ﻧﻜﺎت ﺣﺎﺋﺰ اﻫﻤﻴﺖ در ﺟﺰﺋﻴﺎت ﺳﺎزه ﻫﺎي ﻓﻠﺰي ‪18 ..................................................‬‬

‫‪-7‬‬

‫ﻧﻜﺎت ﻣﻬﻢ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ‪21 ......................................................................‬‬

‫‪-8‬‬

‫ﻧﻜﺎت ﻛﻠﻲ درﺑﺎره ﻓﺎﻳﻞ ﻣﺪل ﻛﺎﻣﭙﻴﻮﺗﺮي ﺳﺎزه ‪25 ....................................................‬‬

‫‪-9‬‬

‫ﻧﻜﺎت ﻣﻬﻢ در ﻓﺎﻳﻞ ﻣﺪل ﻛﺎﻣﭙﻴﻮﺗﺮي ﺳﺎزه ﻫﺎي ﺑﺘﻨﻲ‪30 .............................................‬‬

‫‪-10‬‬

‫ﻧﻜﺎت ﻣﻬﻢ در ﻓﺎﻳﻞ ﻣﺪل ﻛﺎﻣﭙﻴﻮﺗﺮي ﺳﺎزه ﻫﺎي ﻓﻠﺰي ‪33 ...........................................‬‬

‫‪-11‬‬

‫ﻧﻜﺎت ﻣﻬﻢ در ﻓﺎﻳﻞ ﻣﺪل ﻛﺎﻣﭙﻴﻮﺗﺮي ﺷﺎﻟﻮده ‪35 .......................................................‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪2 :‬‬

‫‪ -1‬ﻣﻘﺪﻣﻪ‬ ‫ﺑﺮ اﺳﺎس ﺗﻮاﻓﻘﻨﺎﻣﻪ ﻣﻮرخ ‪ 86/07/17‬ﺑﻴﻦ وزﻳﺮ ﻣﺤﺘﺮم ﻣﺴﻜﻦ و ﺷﻬﺮﺳﺎزي‪ ،‬رﺋﻴﺲ ﻣﺤﺘـﺮم ﺷـﻮراي اﺳـﻼﻣﻲ ﺷـﻬﺮ ﺗﻬـﺮان و رﺋـﻴﺲ‬ ‫ﻣﺤﺘﺮم ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ ﺳﺎﺧﺘﻤﺎن‪ ،‬در اﺟﺮاي ﻣﺎده ‪ 33‬ﻗﺎﻧﻮن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ و ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‪ ،‬ﻣﻘـﺮر ﺷـﺪ در ﺷـﻬﺮ ﺗﻬـﺮان‬ ‫ﺑﺮاﺳﺎس ﻣﻔﺎد ﻣﺒﺤﺚ دوم ﻣﻘﺮرات ﻣﻠﻲ ﺳﺎﺧﺘﻤﺎن‪ ،‬ﻛﻨﺘﺮل ﺗﻄﺒﻴﻖ ﻛﻴﻔﻴﺖ ﺧﺪﻣﺎت ﻣﻬﻨﺪﺳﻲ در ﻣﺮاﺣـﻞ ﻃﺮاﺣـﻲ‪ ،‬اﺟـﺮا و ﻧﻈـﺎرت ﺑـﺎ‬ ‫ﻣﻘﺮرات ﻣﻠﻲ ﺳﺎﺧﺘﻤﺎن‪ ،‬ﺗﻮﺳﻂ ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن‪ ،‬اﻧﺠﺎم ﮔﻴﺮد‪ .‬ﺑﻪ اﻳﻦ ﻣﻨﻈﻮر دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن در ﺳﺎل ‪ 86‬ﻓﻌﺎﻟﻴﺖ‬ ‫ﺧﻮد را آﻏﺎز ﻛﺮده اﺳﺖ و ﺑﺮاي آﺷﻨﺎﻳﻲ ﻣﻬﻨﺪﺳﻴﻦ و ﻛﺎرﻓﺮﻣﺎﻳﺎن ﻣﺤﺘﺮم ﺑﺎ ﻧﺤﻮه ﮔـﺮدش ﻛـﺎر در ﻣﺠﻤﻮﻋـﻪ دﻓﺘـﺮ ﻛﻨﺘـﺮل ﺳـﺎﺧﺘﻤﺎن‪،‬‬ ‫دﻓﺘﺮﭼﻪ "راﻫﻨﻤﺎي ﻣﺘﻘﺎﺿﻴﺎن ﭘﺮواﻧﻪ ﺳﺎﺧﺘﻤﺎن" ﺗﻬﻴﻪ ﺷﺪه اﺳﺖ ﻛﻪ در اﺑﺘﺪاي ﺗﺸﻜﻴﻞ ﭘﺮوﻧﺪه ﺑﻪ ﻣﺘﻘﺎﺿـﻴﺎن ﺗﺤﻮﻳـﻞ داده ﻣـﻲ‬ ‫ﺷﻮد‪.‬‬ ‫ﻋﻼوه ﺑﺮ دﻓﺘﺮﭼﻪ راﻫﻨﻤﺎي ﻣﺬﻛﻮر‪ ،‬ﺑﺮاي آﺷﻨﺎﻳﻲ ﻃﺮاﺣﺎن ﻣﺤﺘﺮم ﺳﺎزه ﺑﺎ اﺻﻮل ﻣﻬﻤﻲ ﻛﻪ ﺑﺎﻳـﺪ در ﻃﺮاﺣـﻲ ﺳـﺎزه و ﺗﻬﻴـﻪ ﻧﻘﺸـﻪ ﻫـﺎ‬ ‫رﻋﺎﻳﺖ ﺷﻮد‪ ،‬در ﮔﺮوه ﻛﻨﺘﺮل ﺳﺎزه ﭼﻚ ﻟﻴﺴﺘﻬﺎﻳﻲ ﺑﺮاي ﻣﺒﺎﺣﺚ ﺷﺸﻢ‪ ،‬ﻧﻬﻢ و دﻫﻢ ﻣﻘﺮرات ﻣﻠﻲ ﺳﺎﺧﺘﻤﺎن و ﻛﺘﺎب اﺻﻮل ﮔﻮدﺑﺮداري‬ ‫و ﺳﺎزه ﻫﺎي ﻧﮕﻬﺒﺎن ﺗﻬﻴﻪ ﺷﺪ ﻛﻪ ﻣﻴﺘﻮاﻧﻨﺪ ﻛﻤﻚ ﺷﺎﻳﺎﻧﻲ ﺟﻬﺖ ﻛﻨﺘﺮل ﻣﻮارد اﺳﺎﺳﻲ ﻃﺮاﺣﻲ ﺳﺎزه ﺑﻪ ﻃﺮاﺣﺎن اراﺋﻪ ﻛﻨﻨﺪ‪ .‬ﺗﻮﺻﻴﻪ ﻣﻲ‬ ‫ﺷﻮد ﻃﺮاﺣﺎن ﻗﺒﻞ از آﻏﺎز ﻓﺮآﻳﻨﺪ ﻃﺮاﺣﻲ‪ ،‬ﺿﻤﻦ ﻣﻄﺎﻟﻌﻪ ﭼﻚ ﻟﻴﺴﺖ ﻫﺎ‪ ،‬ﺟﻬﺖ رﻋﺎﻳﺖ ﻣﻮارد ﻣﻄﺮح ﺷﺪه در ﻣﺤﺎﺳـﺒﺎت و ﻧﻘﺸـﻪ ﻫـﺎ‪،‬‬ ‫ﭘﻴﺶ ﺑﻴﻨﻲ ﻫﺎي ﻻزم را ﺑﻪ ﻋﻤﻞ آورﻧﺪ‪ .‬از ﺳﻮي دﻳﮕﺮ ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﮔﺴﺘﺮدﮔﻲ ﻣﺒﺎﺣﺚ ﻣﺮﺑﻮط ﺑﻪ ﺳﺎزه و ﻋﺪم اﻣﻜﺎن ﺧﻼﺻﻪ ﺳﺎزي آﻧﻬـﺎ‬ ‫در ﭼﻚ ﻟﻴﺴﺖ ﻫﺎ‪ ،‬و ﺑﺎ ﻋﻨﺎﻳﺖ ﺑﻪ اﻳﻨﻜﻪ ﺑﺮﺧﻲ از ﻛﻤﺒﻮدﻫﺎ و ﻧﻘﺎﺋﺺ در اﻏﻠﺐ ﺳﺎزه ﻫﺎي ﻛﻨﺘﺮل ﺷﺪه ﻣﺸﺘﺮك ﺑﻮده اﺳﺖ و ﺑﺎ در ﻧﻈـﺮ‬ ‫ﮔﺮﻓﺘﻦ درﺧﻮاﺳﺖ ﺑﺴﻴﺎري از ﻃﺮاﺣﺎن ﻣﺤﺘﺮم ﺟﻬﺖ اراﺋﻪ ﻳﻚ ﺷﻴﻮه ﻧﺎﻣﻪ ﻣﻜﺘﻮب ﺑﺮاي اﺳﻠﻮب ﻛﻠﻲ ﻃﺮاﺣﻲ ﺳﺎزه‪ ،‬ﮔﺮوه ﻛﻨﺘﺮل ﺳـﺎزه‬ ‫ﺟﻬﺖ ﮔﺮدآوري ﻣﻮارد ﻣﻬﻢ و اﺷﻜﺎﻻت ﻣﺘﺪاول در ﻣﺤﺎﺳﺒﺎت و ﻧﻘﺸﻪ ﻫﺎي ﺳﺎزه‪ ،‬اﻗﺪام ﺑﻪ ﺗﻬﻴﻪ اﻳﻦ دﻓﺘﺮﭼﻪ راﻫﻨﻤـﺎ ﻧﻤـﻮده اﺳـﺖ‪ .‬در‬ ‫ﺗﻬﻴﻪ اﻳﻦ راﻫﻨﻤﺎ ﺳﻌﻲ ﺷﺪه اﺳﺖ ﻣﻄﺎﻟﺐ ﺑﻪ ﻧﺤﻮي ﮔﺮوه ﺑﻨﺪي ﺷﻮﻧﺪ ﻛﻪ ﻃﺮاح ﺳﺎزه ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻫﺮ ﻣﺮﺣﻠﻪ از روﻧﺪ ﻃﺮاﺣﻲ‪ ،‬ﺑﺎ ﻣﺮاﺟﻌﻪ‬ ‫ﺑﻪ ﻳﻜﻲ از ﺑﺨﺸﻬﺎ ﻣﻮارد ﺿﺮوري را ﻣﻄﺎﻟﻌﻪ و در ﻃﺮاﺣﻲ ﻣﺪ ﻧﻈﺮ ﻗﺮار دﻫﺪ‪ .‬ﺷﻤﺎره ﺑﻨﺪﻫﺎي ﻣـﻮرد اﺷـﺎره در اﻳـﻦ ﻧﻮﺷـﺘﺎر ﻣﺮﺑـﻮط ﺑـﻪ‬ ‫ﻣﻘﺮرات ﻣﻠﻲ ﺳﺎﺧﺘﻤﺎن اﺳﺖ ﻛﻪ در ﻫﺮ ﻣﻮرد‪ ،‬ﻋﺪد اول ﻧﺸﺎن دﻫﻨﺪه ﺷﻤﺎره ﻣﺒﺤﺚ ﻣﻮرد ﻧﻈﺮ اﺳﺖ‪ .‬ﻻزم ﺑـﻪ ﺗﻮﺿـﻴﺢ اﺳـﺖ ﻛـﻪ اﻳـﻦ‬ ‫دﻓﺘﺮﭼﻪ ﺻﺮﻓﺎ ﺑﺮاي ﺗﺎﻛﻴﺪ ﺑﺮ روي ﻧﻜﺎت ﺑﺴﻴﺎر ﻣﻬﻢ ﺗﻬﻴﻪ ﺷﺪه اﺳﺖ و ﻃﺮاﺣﺎن ﻣﺤﺘﺮم ﺑﺎﻳﺪ ﻛﻤﺎ ﻓﻲ اﻟﺴﺎﺑﻖ‪ ،‬در ﻃﺮاﺣﻲ ﺳـﺎزه ﺗﻤـﺎﻣﻲ‬ ‫ﺑﺨﺸﻬﺎي ﻣﻘﺮرات ﻣﻠﻲ ﺳﺎﺧﺘﻤﺎن را ﻣﻮرد ﺗﻮﺟﻪ ﻛﺎﻣﻞ ﻗﺮار دﻫﻨﺪ‪ .‬ﺑﻪ ﻫﺮ ﺣﺎل اﻣﻴﺪ اﺳﺖ رﻋﺎﻳﺖ ﻣﻮارد ﻣﻨﺪرج در اﻳﻦ دﻓﺘﺮﭼـﻪ‪ ،‬ﺿـﻤﻦ‬ ‫اﻓﺰاﻳﺶ ﻛﻴﻔﻴﺖ ﺧﺪﻣﺎت ﻣﻬﻨﺪﺳﻲ‪ ،‬ﻣﻮﺟﺐ ﻛﺎﻫﺶ زﻣﺎن رﺳﻴﺪﮔﻲ و ﻛﻨﺘﺮل ﻧﻘﺸﻪ ﻫﺎي ﺳﺎزه ﮔﺮدد‪ .‬ﻫﻤﭽﻨﻴﻦ ﻻزم ﺑـﻪ ذﻛـﺮ اﺳـﺖ در‬ ‫ﺗﻬﻴﻪ اﻳﻦ دﻓﺘﺮﭼﻪ ﺣﺪاﻛﺜﺮ ﺗﻼش ﺑﺮاي ﻛﻨﺘﺮل ﺻﺤﺖ ﻣﻄﺎﻟﺐ اراﺋﻪ ﺷﺪه اﻧﺠﺎم ﮔﺮﻓﺘﻪ اﺳﺖ‪ ،‬ﻟﻴﻜﻦ ﺑﻪ ﻃﻮر ﻳﻘﻴﻦ ﺧﻮاﻧﻨﺪﮔﺎن ﻣﺤﺘـﺮم در‬ ‫ﺑﺮﺧﻲ ﻣﻮارد ﻣﻤﻜﻦ اﺳﺖ ﻧﻈﺮات ﻣﺘﻔﺎوﺗﻲ ﺟﻬﺖ اﺻﻼح ﻳﺎ ﺑﻬﺒﻮد اﻳﻦ ﻧﻮﺷﺘﺎر داﺷﺘﻪ ﺑﺎﺷﻨﺪ‪ .‬ﻟﺬا ﺧﻮاﻫﺸﻤﻨﺪ اﺳﺖ ﻃﺮاﺣـﺎن ﻣﺤﺘـﺮم‪ ،‬ﺑـﺎ‬ ‫اراﺋﻪ ﻧﻈﺮات اﺻﻼﺣﻲ ﺧﻮد ﮔﺮوه ﻛﻨﺘﺮل ﺳﺎزه را ﺑﺮاي ﺗﻜﻤﻴﻞ اﻳﻦ دﻓﺘﺮﭼﻪ راﻫﻨﻤﺎ ﻳﺎري ﻓﺮﻣﺎﻳﻨﺪ‪ .‬ﻟﻄﻔـﺎ ﺧﻮاﻧﻨـﺪﮔﺎن ﻣﺤﺘـﺮم ﻧﻈـﺮات و‬

‫ﭘﻴﺸﻨﻬﺎدات ﺧﻮد را ﺑﻪ ﺻﻮرت ﻣﻜﺘﻮب ﺑﻪ ﻧﺸﺎﻧﻲ " ﺗﻬﺮان‪ -‬ﺷﻬﺮك ﻗﺪس )ﻏﺮب(‪ -‬ﻓﺎز ﻳﻚ ‪ -‬ﺧﻴﺎﺑﺎن ﻣﻬﺴﺘﺎن ‪ -‬ﻛﻮﭼﻪ ﭼﻬﺎرم‬ ‫‪ -‬ﭘﻼك ‪ -155‬ﻃﺒﻘﻪ ‪ -3‬واﺣﺪ ﻛﻨﺘﺮل ﺳﺎزه" ﻳﺎ ﻧﺸﺎﻧﻲ اﻟﻜﺘﺮوﻧﻴﻜﻲ ‪ [email protected]‬ارﺳﺎل ﻓﺮﻣﺎﻳﻨﺪ‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫دا ﻧ ﻮ‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫ﺻﻔﺤﻪ‪3 :‬‬

‫‪ -2‬ﻣﺪارك ﻻزم‬

‫ﺟﻬﺖ اﻧﺠﺎم ﻫﺮ ﭼﻪ ﺳﺮﻳﻌﺘﺮ ﻣﺮاﺣﻞ ﻛﻨﺘﺮل‪ ،‬ﺧﻮاﻫﺸﻤﻨﺪ اﺳـﺖ در ﻣﻮرد ﺑﺨـﺶ ﺳـﺎزه‪ ،‬ﻣـﻮارد ذﻳـﻞ در ﻣﺮاﺣـﻞ‬ ‫ﻣﺨﺘﻠﻒ ﺗﺤﻮﻳﻞ ﻣﺪارك ﺑﻪ ﺳﺎزﻣﺎن‪ ،‬ﻣﺪ ﻧﻈﺮ ﻗﺮار ﮔﻴﺮد ﺗﺎ ﺗﺎﺧﻴﺮي ﺑﻪ ﻋﻠﺖ ﻧﻘﺺ ﻣﺪارك در ﻛﻨﺘﺮل ﻧﻘﺸـﻪ ﻫـﺎ روي‬ ‫ﻧﺪﻫﺪ‪:‬‬ ‫‪ .1‬ﻟﻮح ﻓﺸﺮده ﺷﺎﻣﻞ ﻛﻠﻴﻪ ﻧﻘﺸﻪ ﻫﺎي ﻣﻌﻤﺎري – ﺳﺎزه – ﺑﺮق – ﻣﻜﺎﻧﻴﻚ ﺑﺎ ﻓﺮﻣﺖ اﺗﻮﻛﺪي و ﻓﺎﻳﻠﻬﺎي ﻣﺤﺎﺳﺒﺎﺗﻲ‬ ‫ﻣﺮﺑﻮﻃﻪ )ﻓﺎﻳﻠﻬﺎي ﻣﺤﺎﺳﺒﺎﺗﻲ ﺳﺎزه ﻫﻢ در ﻓﺮﻣﺖ اﺻﻠﻲ ﻧﺮم اﻓﺰار و ﻫﻢ در ﻓﺮﻣﺖ ﻣﺘﻨﻲ اراﺋﻪ ﺷﻮﻧﺪ(‬ ‫‪ .2‬ﻳﻚ ﺳﺮي ﭼﺎپ ﻧﻘﺸﻪ ﻫﺎي ﻓﺎز ‪ 2‬ﺳﺎزه ﻣﻤﻬﻮر ﺑﻪ ﻣﻬﺮ ﺷﺮﻛﺖ و ﺷﺨﺺ ﻃﺮاح ﺑﺎ ذﻛﺮ ﭘﺮواﻧﻪ اﺷﺘﻐﺎل ﺣﻘﻮﻗﻲ و‬ ‫ﺣﻘﻴﻘﻲ‬ ‫‪ .3‬دﻓﺘﺮﭼﻪ ﮔﺰارش ﻣﻜﺎﻧﻴﻚ ﺧﺎك ﻛﻪ ﺑﻨﺎ ﺑﻪ درﺧﻮاﺳﺖ ﺷﻬﺮداري ﻣﻨﻄﻘﻪ ﺗﻬﻴﻪ ﺷﺪه ﺑﺎﺷﺪ‪ ،‬ﻣﻤﻬﻮر ﺑﻪ ﻣﻬﺮ ﺷﺮﻛﺖ ﺗﻬﻴﻪ‬ ‫ﻛﻨﻨﺪه ﮔﺰارش ﻣﻜﺎﻧﻴﻚ ﺧﺎك‬ ‫‪ .4‬دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ﺳﺎزه‪ ،‬ﻣﻤﻬﻮر ﺑﻪ ﻣﻬﺮ ﺷﺮﻛﺖ و ﺷﺨﺺ ﻃﺮاح ﺑﺎ ذﻛﺮ ﭘﺮواﻧﻪ اﺷﺘﻐﺎل ﺣﻘﻮﻗﻲ و ﺣﻘﻴﻘﻲ‬ ‫‪ .5‬ﭼﻚ ﻟﻴﺴﺖ ﻫﺎي ﺳﺎزه )ﻣﺒﺤﺚ ‪ 9 ،6‬و ‪ 10‬ﻣﻘﺮرات ﻣﻠﻲ ﺳﺎﺧﺘﻤﺎن(‪ ،‬ﻛﻪ ﺗﻮﺳﻂ ﺳﺎزﻣﺎن ﺗﻬﻴﻪ ﺷﺪه اﻧﺪ‪ ،‬ﻣﻤﻬﻮر ﺑﻪ‬ ‫ﻣﻬﺮ ﺷﺮﻛﺖ و ﺷﺨﺺ ﻃﺮاح ﺑﺎ ذﻛﺮ ﭘﺮواﻧﻪ اﺷﺘﻐﺎل ﺣﻘﻮﻗﻲ و ﺣﻘﻴﻘﻲ‬ ‫‪ .6‬در ﻫﺮ ﻣﺮﺣﻠﻪ از ﻛﻨﺘﺮل ﻧﻘﺸﻪ ﻫﺎ‪ ،‬ﻣﻤﻜﻦ اﺳﺖ ﺑﺮﺧﻲ ﻣﻮارد اﺻﻼﺣﻲ در ﻧﻘﺸﻪ ﻫﺎ درج ﮔﺮدد‪ .‬ﭘﺲ از اﺻﻼح اﻳﻦ‬ ‫ﻣﻮارد ﺑﺎﻳﺪ ﻧﻘﺸﻪ ﻫﺎي اﻇﻬﺎر ﻧﻈﺮ ﺷﺪه در ﻣﺮﺣﻠﻪ ﺑﻌﺪي ﺗﺤﻮﻳﻞ ﻧﻘﺸﻪ ﻫﺎ و ﻣﺪارك‪ ،‬ﺑﻪ ﺳﺎزﻣﺎن ﻋﻮدت داده ﺷﻮﻧﺪ‪.‬‬ ‫‪ .7‬ﭘﺲ از ﻫﺮ ﻣﺮﺣﻠﻪ ﻛﻨﺘﺮل ﻧﻘﺸﻪ‪ ،‬ﻣﻮاردي ﻛﻪ اﺣﺘﻴﺎج ﺑﻪ اﺻﻼح دارﻧﺪ در ﻓﺮﻣﻬﺎي ﻣﻌﻴﻨﻲ در ﻳﻚ ﻳﺎ ﭼﻨﺪ ﺻﻔﺤﻪ ﺑﻪ‬ ‫ﻃﺮاح ﺳﺎزه ﺗﺤﻮﻳﻞ داده ﻣﻲ ﺷﻮد‪ .‬در ﻣﺮﺣﻠﻪ ﺑﻌﺪي ارﺳﺎل ﻣﺪارك اﺻﻼح ﺷﺪه ﺑﻪ ﺳﺎزﻣﺎن‪ ،‬ﻻزم اﺳﺖ ﻃﺮاح ﺳﺎزه‬ ‫ﭘﺎﺳﺨﻬﺎي ﺧﻮد درﺑﺎره ﻧﺤﻮه اﻧﺠﺎم اﺻﻼﺣﺎت و ﻳﺎ ﻫﺮﮔﻮﻧﻪ ﻧﻈﺮ دﻳﮕﺮي درﻣﻮرد اﺷﻜﺎﻻت ﻣﻄﺮح ﺷﺪه را در ﺳﺮﺑﺮگ‬ ‫رﺳﻤﻲ ﺷﺮﻛﺖ ﻃﺮاح‪ ،‬ﺑﺎ ﻣﻬﺮ و اﻣﻀﺎي ﺧﻮد و ﻣﻬﺮ ﺷﺮﻛﺖ ﺑﻪ ﺳﺎزﻣﺎن ﺗﺤﻮﻳﻞ دﻫﺪ‪ .‬در ﺻﻮرت ﻋﺪم اراﺋﻪ‬ ‫ﭘﺎﺳﺨﻬﺎ‪ ،‬اﻣﻜﺎن ﻛﻨﺘﺮل ﻣﺠﺪد ﻣﺪارك ﻣﻴﺴﺮ ﻧﺨﻮاﻫﺪ ﺑﻮد‪.‬‬ ‫‪ .8‬ﭘﺲ از اﺧﺬ ﺗﺎﻳﻴﺪ ﻧﻬﺎﻳﻲ ﻧﻘﺸﻪ ﻫﺎي ﻓﺎز ‪ 2‬ﻛﻠﻴﻪ رﺷﺘﻪ ﻫﺎ ﻻزم اﺳﺖ ﻟﻮح ﻓﺸﺮده ﺷﺎﻣﻞ ﻛﻠﻴﻪ ﻧﻘﺸﻪ ﻫﺎي ﻧﻬﺎﻳﻲ‬ ‫ﺷﺪه ﻣﻌﻤﺎري – ﺳﺎزه – ﺑﺮق – ﻣﻜﺎﻧﻴﻚ ﺑﺎ ﻓﺮﻣﺖ اﺗﻮﻛﺪي و ﻓﺎﻳﻠﻬﺎي ﻣﺤﺎﺳﺒﺎﺗﻲ ﻣﺮﺑﻮﻃﻪ ﺑﻪ ﮔﺮوه ﻣﻌﻤﺎري‬ ‫ﺗﺤﻮﻳﻞ ﮔﺮدد‪ .‬ﮔﺮوه ﻛﻨﺘﺮل ﻣﻌﻤﺎري در اﻳﻦ ﻣﺮﺣﻠﻪ ﺗﻄﺎﺑﻖ ﻛﻠﻲ ﻧﻘﺸﻪ ﻫﺎي ﭼﻬﺎر رﺷﺘﻪ را ﺑﺎ ﻳﻜﺪﻳﮕﺮ ﺑﺮرﺳﻲ ﻧﻤﻮده‬ ‫و در ﺻﻮرت ﻟﺰوم اﺻﻼﺣﺎت ﻣﻮرد ﻧﻈﺮ را ﻣﺸﺨﺺ ﻣﻴﻜﻨﺪ‪ .‬ﭘﺲ از اﻋﻼم ﻧﻈﺮ ﻧﻬﺎﻳﻲ ﮔﺮوه ﻣﻌﻤﺎري ﻣﺒﻨﻲ ﺑﺮ ﺗﺎﻳﻴﺪ‬ ‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪4 :‬‬

‫ﻫﻤﺎﻫﻨﮕﻲ ﻧﻘﺸﻪ ﻫﺎ‪ ،‬ﻣﺠﻮز ﭼﺎپ ﻧﻘﺸﻪ ﻫﺎي ﻧﻬﺎﻳﻲ ﺻﺎدر ﻣﻲ ﺷﻮد‪ .‬در اﻳﻦ ﻣﺮﺣﻠﻪ ﺑﺎﻳﺪ ﻣﺪارك ذﻳﻞ ﺗﺤﻮﻳﻞ‬ ‫ﺳﺎزﻣﺎن ﮔﺮدد‪:‬‬ ‫اﻟﻒ( دﻓﺘﺮﭼﻪ ﺗﻜﻤﻴﻞ ﺷﺪه اﻃﻼﻋﺎت ﺳﺎﺧﺘﻤﺎن و ﻣﻤﻬﻮر ﺑﻪ ﻣﻬﺮ ﺷﺮﻛﺖ و ﺷﺨﺺ ﻃﺮاح‬ ‫ب( ﭘﻨﺞ ﺳﺮي ﻧﻘﺸﻪ از ﻛﻠﻴﻪ رﺷﺘﻪ ﻫﺎ‪ ،‬ﻣﻤﻬﻮر ﺑﻪ ﻣﻬﺮ ﺷﺮﻛﺖ و ﺷﺨﺺ ﻃﺮاح ﺟﻬﺖ ﻧﺼﺐ ﻫﻮﻟﻮﮔﺮام و ارﺳﺎل ﺑﻪ‬ ‫ﺷﻬﺮداري ﻣﻨﻄﻘﻪ ﻣﺮﺑﻮﻃﻪ‬ ‫پ( ﻟﻮح ﻓﺸﺮده ﺷﺎﻣﻞ ﻛﻠﻴﻪ ﻧﻘﺸﻪ ﻫﺎي ﻧﻬﺎﻳﻲ ﻣﻌﻤﺎري – ﺳﺎزه – ﺑﺮق – ﻣﻜﺎﻧﻴﻚ و ﻓﺎﻳﻠﻬﺎي ﻣﺤﺎﺳﺒﺎﺗﻲ ﻧﻬﺎﻳﻲ‬ ‫ﻣﺮﺑﻮﻃﻪ‬ ‫ت( دو ﺳﺮي از دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ﻧﻬﺎﻳﻲ )ﻳﻚ ﻧﺴﺨﻪ اﺻﻞ و ﻳﻚ ﻧﺴﺨﻪ ﻛﭙﻲ ﻣﻮرد ﻗﺒﻮل اﺳﺖ(‬ ‫ث( دو ﺳﺮي از ﭼﻚ ﻟﻴﺴﺘﻬﺎي ﻧﻬﺎﻳﻲ‬ ‫ج( دو ﺳﺮي از دﻓﺘﺮﭼﻪ ﻣﻜﺎﻧﻴﻚ ﺧﺎك )ﻳﻚ ﻧﺴﺨﻪ اﺻﻞ و ﻳﻚ ﻧﺴﺨﻪ ﻛﭙﻲ ﻣﻮرد ﻗﺒﻮل اﺳﺖ(‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪5 :‬‬

‫‪ -3‬ﻣﻮارد ﻛﻠﻲ درﺑﺎره ﻧﻘﺸﻪ ﻫﺎي ﺷﺎﻟﻮده‬

‫‪ .1‬در ﻧﻘﺸﻪ ﻫﺎي ﻗﺎﻟﺐ ﺑﻨﺪي و آرﻣﺎﺗﻮرﮔﺬاري ﺷﺎﻟﻮده‪ ،‬در ﻣﺤﻠﻬﺎي ﺗﻐﻴﻴﺮ ﺗﺮاز‪ ،‬ﻣﻘﺎﻃﻊ ﻃﻮﻟﻲ و ﻋﺮﺿﻲ ﻛﺎﻓﻲ ﺟﻬﺖ‬ ‫روﺷﻦ ﺷﺪن ﻧﺤﻮه ﻗﺎﻟﺐ ﺑﻨﺪي و آرﻣﺎﺗﻮرﮔﺬاري اراﺋﻪ ﮔﺮدد‪.‬‬ ‫‪ .2‬ﻧﻮع ﺳﻴﻤﺎن ﻣﺼﺮﻓﻲ ذﻛﺮ ﺷﺪه در ﺗﻮﺿﻴﺤﺎت ﻧﻘﺸﻪ ﻫﺎ ﺑﺮاي ﺳﺎﺧﺖ ﺑﺘﻦ‪ ،‬ﻃﺒﻖ ﺗﻮﺻﻴﻪ ﮔﺰارش ﻣﻜﺎﻧﻴﻚ ﺧﺎك درج‬ ‫ﮔﺮدد‪.‬‬ ‫‪ .3‬ﻣﺤﻞ و ﻗﻄﺮ ﭼﺎﻫﻬﺎي ﻓﺎﺿﻼب‪ ،‬آب ﺑﺎران و ﭼﺎه ارت در ﻧﻘﺸﻪ ﻫﺎي ﺷﺎﻟﻮده ﺑﻪ ﺻﻮرت ﺧﻂ ﭼﻴﻦ ﻧﺸﺎن داده‬ ‫ﺷﻮد‪.‬‬ ‫‪ .4‬در ﺻﻮرت اﺳﺘﻔﺎده از ﺷﻤﻊ در ﺷﺎﻟﻮده‪ ،‬ﻣﻘﻄﻊ ﭘﺎﺷﻨﻪ ﭘﺎﻳﻴﻦ ﺷﻤﻊ در ﻧﻘﺸﻪ ﻫﺎ ﺑﻪ ﻧﺤﻮي ﺗﺮﺳﻴﻢ ﺷﻮد ﻛﻪ وارد ﺣﺮﻳﻢ‬ ‫ﻫﻤﺴﺎﻳﻪ ﻳﺎ ﮔﺬر ﻧﺸﻮد‪ .‬در ﺻﻮرﺗﻴﻜﻪ ﻋﻤﻖ ﺷﻤﻊ ﻛﻢ ﺑﻮده )ﻛﻤﺘﺮ از ﺣﺪود ‪ 15‬ﻣﺘﺮ( و ﺑﻪ ﻻﻳﻪ ﻣﻘﺎوم ﺑﺴﺘﺮ ﺳﻨﮕﻲ‬ ‫ﻧﺮﺳﺪ‪ ،‬ﺑﺎﻳﺪ از ﻣﺪل ﺳﺎزي آن در ﻓﺎﻳﻞ ﻓﻮﻧﺪاﺳﻴﻮن ﺻﺮﻓﻨﻈﺮ ﺷﻮد‪ .‬در ﺻﻮرﺗﻲ ﻛﻪ ﺷﻤﻊ ﻋﻤﻴﻖ ﺑﺎﺷﺪ‪ ،‬ﺑﺎ ﻣﺤﺎﺳﺒﻪ‬ ‫ﺳﺨﺘﻲ ﺑﺮ ﻣﺒﻨﺎي ﮔﺰارش ﻣﻜﺎﻧﻴﻚ ﺧﺎك‪ ،‬در ﻣﺪل ﻓﻮﻧﺪاﺳﻴﻮن در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﺪه و ﭘﺲ از ﺗﺤﻠﻴﻞ ﺑﺎﻳﺪ ﺑﺮاي‬ ‫ﻧﻴﺮوﻫﺎي ﻓﺸﺎري و ﻛﺸﺸﻲ وارد ﺑﺮآن ﻛﻨﺘﺮل و ﻃﺮاﺣﻲ اﺑﻌﺎدي و ﻣﺤﺎﺳﺒﻪ آرﻣﺎﺗﻮرﮔﺬاري اﻧﺠﺎم ﮔﻴﺮد‪.‬‬ ‫‪ .5‬در ﺻﻮرت وﺟﻮد ﺗﺼﻔﻴﻪ ﺧﺎﻧﻪ اﺳﺘﺨﺮ ﺟﻬﺖ اﺟﺘﻨﺎب از ﻫﻮا ﮔﺮﻓﺘﻦ ﭘﻤﭗ ﻫﺎي ﺗﺼﻔﻴﻪ ﺧﺎﻧﻪ‪ ،‬ﺑﺎﻳﺪ ﺗﺮاز ﻓﻀﺎي‬ ‫ﺗﺼﻔﻴﻪ ﺧﺎﻧﻪ ﭘﺎﻳﻴﻦ ﺗﺮ از اﺳﺘﺨﺮ ﺑﺎﺷﺪ‪ .‬ﻫﻤﭽﻨﻴﻦ ﺟﺰﺋﻴﺎت ﺳﺎزه ﺗﺼﻔﻴﻪ ﺧﺎﻧﻪ ﺑﻪ ﻧﺤﻮي در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد ﻛﻪ ﺑﺎ‬ ‫ﻓﻮﻧﺪاﺳﻴﻮن ﺳﺎﺧﺘﻤﺎن ﺗﺪاﺧﻞ ﻧﺪاﺷﺘﻪ ﺑﺎﺷﺪ‪.‬‬ ‫‪ .6‬اراﺋﻪ ﻳﻚ ﺳﺮي ﻣﻘﺎﻃﻊ ﻛﻠﻲ ﺑﺮاي آرﻣﺎﺗﻮر ﮔﺬاري ﺷﺎﻟﻮده ﻛﺎﻓﻲ ﻧﻴﺴﺖ‪ .‬در ﻧﻘﺸﻪ آرﻣﺎﺗﻮر ﮔﺬاري ﺷﺎﻟﻮده ﺑﺎﻳﺪ ﭘﻼن‬ ‫آرﻣﺎﺗﻮر ﮔﺬاري ﺳﺮاﺳﺮي و ﺗﻘﻮﻳﺘﻲ ﺟﺪاﮔﺎﻧﻪ اراﺋﻪ ﺷﻮد و ﻣﻘﺎﻃﻊ ﻻزم )ﺑﻪ وﻳﮋه در ﻣﺤﻠﻬﺎي ﻣﻴﻠﮕﺮد ﺗﻘﻮﻳﺘﻲ(‬ ‫رﺳﻢ ﺷﻮد‪ .‬در ﭘﻼن آرﻣﺎﺗﻮرﮔﺬاري ﺳﺮاﺳﺮي ﺑﺎﻳﺪ ﻣﺤﻞ و ﻃﻮل وﺻﻠﻪ ﻫﺎ ﺑﻪ وﺿﻮح ﻣﺸﺨﺺ ﺷﻮد‪ .‬وﺻﻠﻪ ﻣﻴﻠﮕﺮدﻫﺎي‬ ‫ﭘﺎﻳﻴﻨﻲ در وﺳﻂ دﻫﺎﻧﻪ ﻫﺎ و وﺻﻠﻪ ﻣﻴﻠﮕﺮدﻫﺎي ﺑﺎﻻﻳﻲ در ﻧﺰدﻳﻜﻲ ﺳﺘﻮﻧﻬﺎ اﻧﺠﺎم ﮔﻴﺮد‪.‬‬ ‫‪ .7‬در ﺳﺎﺧﺘﻤﺎﻧﻬﺎي داراي اﺳﺘﺨﺮ‪ ،‬در ﺻﻮرﺗﻲ ﻛﻪ ﺷﺎﻟﻮده اﺳﺘﺨﺮ و ﺳﺎزه‪ ،‬ﺑﻪ ﻃﻮر ﻳﻜﭙﺎرﭼﻪ در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪ ،‬ﺑﺎﻳﺪ‬ ‫ﻣﺪل ﺳﺎزي ﺷﺎﻟﻮده ﻧﻴﺰ ﺑﺎ در ﻧﻈﺮ ﮔﺮﻓﺘﻦ اﻳﻦ ﻣﺴﺎﻟﻪ اﻧﺠﺎم ﺷﻮد‪ .‬در ﺻﻮرت وﺟﻮد درز ﻳﺎ ﻓﺎﺻﻠﻪ ﺑﻴﻦ اﺳﺘﺨﺮ و‬ ‫ﺷﺎﻟﻮده ﺳﺎزه‪ ،‬ﺑﺎﻳﺪ ﺗﻤﻬﻴﺪات ﻻزم ﺟﻬﺖ ﺟﻠﻮﮔﻴﺮي از وارد ﺷﺪن ﻓﺸﺎر ﺟﺎﻧﺒﻲ ﺧﺎك زﻳﺮ ﺷﺎﻟﻮده ﺑﻪ دﻳﻮاره اﺳﺘﺨﺮ‬ ‫اﻧﺪﻳﺸﻴﺪه ﺷﻮد‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪6 :‬‬

‫‪ .8‬ﺟﻬﺖ اﺟﺮاي ﻗﺎب ﻓﻠﺰي آﺳﺎﻧﺴﻮر‪ ،‬ورﻗﻬﺎي ﻣﺪﻓﻮن در ﺑﺘﻦ در ﭼﻬﺎر ﮔﻮﺷﻪ ﻛﻒ ﭼﺎﻟﻪ آﺳﺎﻧﺴﻮر ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﻮد‪.‬‬ ‫‪ .9‬ﻃﺒﻖ ﺑﻨﺪ ‪ 3-5-17-9‬ﻣﺒﺤﺚ ﻧﻬﻢ‪ ،‬ﺑﺎﻳﺪ ﻓﺎﺻﻠﻪ ﻣﺤﻮر ﺑﻪ ﻣﺤﻮر ﻣﻴﻠﮕﺮدﻫﺎي ﺷﺎﻟﻮده‪ ،‬ﺣﺪاﻗﻞ ‪ 100‬ﻣﻴﻠﻴﻤﺘﺮ و‬ ‫ﺣﺪاﻛﺜﺮ ‪ 350‬ﻣﻴﻠﻴﻤﺘﺮ رﻋﺎﻳﺖ ﺷﻮد‪ .‬ﻫﻤﭽﻨﻴﻦ در ﺷﺎﻟﻮده ﻫﺎي ﻧﻮاري‪ ،‬ﻃﺒﻖ ﺑﻨﺪ ‪ 2-5-17-9‬ﺣﺪاﻗﻞ درﺻﺪ‬ ‫آرﻣﺎﺗﻮر ﻛﺸﺸﻲ ﺑﺮاﺑﺮ ‪) 0/25%‬ﺑﺮاي آرﻣﺎﺗﻮر ﻣﺤﺎﺳﺒﺎﺗﻲ( ﻳﺎ ‪) 0/15%‬ﺑﺮاي ﺣﺎﻟﺘﻲ ﻛﻪ آرﻣﺎﺗﻮر ﻣﻮﺟﻮد ﺑﻴﺶ از ‪4/3‬‬ ‫آرﻣﺎﺗﻮر ﻣﺤﺎﺳﺒﺎﺗﻲ ﺑﺎﺷﺪ( رﻋﺎﻳﺖ ﮔﺮدد‪.‬‬ ‫‪ .10‬ﺟﺰﺋﻴﺎت ﻻزم ﺑﺮاي اﺗﺼﺎل ﺳﻴﺴﺘﻢ ارت ﺑﻪ اﺳﻜﻠﺖ ﻓﻠﺰي )ﺑﺮاي ﺳﺎزه ﻫﺎي ﻓﻠﺰي( ﻳﺎ ﻣﻴﻠﮕﺮد ﻓﻮﻧﺪاﺳﻴﻮن )ﺑﺮاي‬ ‫ﺳﺎزه ﻫﺎي ﺑﺘﻨﻲ( ﺗﻮﺳﻂ ﻃﺮاح ﺑﺮق ﺳﺎﺧﺘﻤﺎن اراﺋﻪ ﮔﺮدد‪ .‬ﻻزم اﺳﺖ اﻳﻦ ﺟﺰﺋﻴﺎت ﺗﻴﭗ ﻫﻢ در ﻧﻘﺸﻪ ﻫﺎي ﺑﺮق و‬ ‫ﻫﻢ در ﻧﻘﺸﻪ ﻫﺎي ﺷﺎﻟﻮده درج ﮔﺮدد ﺗﺎ در زﻣﺎن اﺟﺮاي ﺷﺎﻟﻮده ﻣﺪ ﻧﻈﺮ ﻣﺠﺮي ﺳﺎزه ﻗﺮار ﮔﻴﺮد‪.‬‬ ‫‪ .11‬در ﺻﻮرت ﻧﻴﺎز ﺑﻪ درز اﻧﺒﺴﺎط در ﺳﺎزه‪ ،‬ﻃﺒﻖ ﺑﺨﺶ ‪ 2-7-9-9‬ﺑﺎﻳﺪ درز اﻧﺒﺴﺎط در ﺷﺎﻟﻮده ﻧﻴﺰ اداﻣﻪ ﻳﺎﺑﺪ‪.‬‬ ‫‪ .12‬در ﺗﻮﺿﻴﺤﺎت ﻋﻤﻮﻣﻲ ﻧﻘﺸﻪ ﺳﺎزه‪ ،‬ﻧﻮع ﻣﺼﺎﻟﺢ ﻓﺮض ﺷﺪه ﺑﺮاي ﺗﻴﻐﻪ ﺑﻨﺪي ﻣﻌﻤﺎري و دﻳﻮار ﭘﻴﺮاﻣﻮﻧﻲ‪ ،‬ﺑﺎ ذﻛﺮ‬ ‫ﺣﺪاﻛﺜﺮ وزن ﻣﺠﺎز ﺑﺮاي واﺣﺪ ﺳﻄﺢ ﺗﻴﻐﻪ ﺑﻨﺪي و دﻳﻮار ﭘﻴﺮاﻣﻮﻧﻲ ﺑﻪ ﺗﻔﻜﻴﻚ )ﺷﺎﻣﻞ دﻳﻮار و ﻧﺎزك ﻛﺎري( درج‬ ‫ﺷﻮد‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪7 :‬‬

‫‪ -4‬ﻣﻮارد ﻋﻤﻮﻣﻲ در ﻧﻘﺸﻪ ﻫﺎي ﺳﺎزه‬

‫‪.1‬‬

‫ﺗﺎﻳﺘﻞ ﻧﻘﺸﻪ ﻫﺎ ﻃﺒﻖ ﺗﺎﻳﺘﻞ ﺗﻨﻈﻴﻢ ﺷﺪه ﺷﺪه ﺗﻮﺳﻂ ﺳﺎزﻣﺎن ﻛﻪ در اﺑﺘﺪاي ﺗﺸﻜﻴﻞ ﭘﺮوﻧﺪه ﺑﻪ ﻣﺘﻘﺎﺿﻲ‬ ‫ﺗﺤﻮﻳﻞ داده ﻣﻲ ﺷﻮد‪ ،‬اراﺋﻪ ﺷﻮد و ﻛﻠﻴﻪ اﻃﻼﻋﺎت ﺧﻮاﺳﺘﻪ ﺷﺪه در ﺗﺎﻳﺘﻞ درج ﮔﺮدد‪ .‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﺗﺎﻳﺘﻞ ﻧﻘﺸﻪ ﻫﺎ‬ ‫ﺑﺮاي ﺷﻴﺖ اول ﺑﺎ ﺗﺎﻳﺘﻞ ﺑﻘﻴﻪ ﺷﻴﺘﻬﺎ ﻣﺘﻔﺎوت اﺳﺖ‪.‬‬

‫‪.2‬‬

‫ﻣﺤﻞ و اﺑﻌﺎد درز اﻧﻘﻄﺎع‪ ،‬در ﻛﻠﻴﻪ ﭘﻼﻧﻬﺎ ﻧﺸﺎن داده ﺷﻮد‪ .‬ﺣﺪاﻗﻞ ﻋﺮض درز اﻧﻘﻄﺎع ﻃﺒﻖ ﺑﻨﺪ ‪4-3-1-7-6‬‬ ‫از ﻣﺮز زﻣﻴﻦ ﻣﺠﺎور ﺑﺮاﺑﺮ ‪ 0/005‬ارﺗﻔﺎع ﻃﺒﻘﻪ از ﺗﺮاز ﭘﺎﻳﻪ در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪ .‬ﺑﺮاي ﺳﺎﺧﺘﻤﺎﻧﻬﺎي ﺑﺎ اﻫﻤﻴﺖ‬ ‫"ﺧﻴﻠﻲ زﻳﺎد" و "زﻳﺎد" و ﻳﺎ درﺳﺎﻳﺮ ﺳﺎﺧﺘﻤﺎﻧﻬﺎي ﺑﺎ ﻫﺸﺖ ﻃﺒﻘﻪ و ﺑﻴﺸﺘﺮ‪ ،‬ﺣﺪاﻗﻞ ﻋﺮض درز اﻧﻘﻄﺎع از ﻣﺮز زﻣﻴﻦ‬ ‫ﻣﺠﺎور ﺑﺮاﺑﺮ ﻧﺼﻒ ﺣﺎﺻﻠﻀﺮب ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﺟﺎﻧﺒﻲ ﻃﺮح ﻃﺒﻘﻪ در ﺿﺮﻳﺐ رﻓﺘﺎر ‪ R‬در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪.‬‬

‫‪.3‬‬

‫ﻧﻘﺸﻪ ﺳﺎزه ﻧﮕﻬﺒﺎن ﺑﺎﻳﺪ ﻃﺒﻖ ﻧﺘﺎﻳﺞ ﮔﺰارش ﻣﻜﺎﻧﻴﻚ ﺧﺎك‪ ،‬ﺑﺮ ﻣﺒﻨﺎي ﻧﺸﺮﻳﻪ وزارت ﻣﺴﻜﻦ ﺑﺮاي ﻃﺮاﺣﻲ‬ ‫ﺳﺎزه ﻫﺎي ﻧﮕﻬﺒﺎن ﺗﻬﻴﻪ ﺷﻮد‪ .‬ﻧﻘﺸﻪ ﺳﺎزه ﻧﮕﻬﺒﺎن ﺑﺎﻳﺪ ﺷﺎﻣﻞ ﭘﻼن‪ ،‬ﻣﻘﺎﻃﻊ‪ ،‬ﺧﺮﭘﺎ‪ ،‬ﺷﻤﻊ )در ﺻﻮرت ﻧﻴﺎز( و‬ ‫ﺟﺰﺋﻴﺎت اﺗﺼﺎل آﻧﻬﺎ ﺑﺎﺷﺪ‪ .‬ﭘﻲ ﻣﺮﺑﻮط ﺑﻪ ﺧﺮﭘﺎ ﻧﻴﺰ ﺑﺎ ﺟﺰﺋﻴﺎت ﻛﺎﻣﻞ ﺑﺎﻳﺪ اراﺋﻪ ﮔﺮدد‪ .‬ﺟﺰﺋﻴﺎت ﭘﺎرﻣﺘﺮﻫﺎي ﻃﺮاﺣﻲ‬ ‫ﺳﺎزه ﻧﮕﻬﺒﺎن و ﻧﺤﻮه اﻧﺘﺨﺎب ﺧﺮﭘﺎي ﻣﺮﺑﻮﻃﻪ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ذﻛﺮ ﺷﻮد‪ .‬اﮔﺮ ارﺗﻔﺎع ﺧﺮﭘﺎي ﻣﻮرد ﻧﻴﺎز ﺑﻴﺸﺘﺮ‬ ‫از ‪ 16‬ﻣﺘﺮ ﺑﺎﺷﺪ‪ ،‬ﺑﺎﻳﺪ ﻃﺮاﺣﻲ ﺧﺮﭘﺎ ﺑﺮ ﻣﺒﻨﺎي رواﺑﻂ اراﺋﻪ ﺷﺪه در ﻛﺘﺎب اﺻﻮل ﮔﻮدﺑﺮداري و ﺳﺎزه ﻫﺎي ﻧﮕﻬﺒﺎن در‬ ‫دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ذﻛﺮ ﮔﺮدد ﻳﺎ از روﺷﻬﺎي دﻳﮕﺮ ﺑﺮاي ﭘﺎﻳﺪاري ﮔﻮد‪ ،‬ﺑﺎ ذﻛﺮ رﻳﺰ ﻣﺤﺎﺳﺒﺎت در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت‬ ‫اﺳﺘﻔﺎده ﺷﻮد‪.‬‬

‫‪.4‬‬

‫ﺣﺪاﻗﻞ ﻋﻤﻖ ﭼﺎﻟﻪ آﺳﺎﻧﺴﻮر از اوﻟﻴﻦ ﺗﺮاز ﺗﻮﻗﻒ ﺑﺎﻳﺪ ﻃﺒﻖ ﺿﻮاﺑﻂ ﭘﻴﻮﺳﺖ ‪ 2‬ﻣﺒﺤﺚ ﭘﺎﻧﺰدﻫﻢ ﺗﻌﻴﻴﻦ ﺷﻮد ﺑـﻪ‬ ‫ﻫﺮ ﺣﺎل اﻳﻦ ﻋﻤﻖ ﻧﺒﺎﻳﺪ ﻛﻤﺘﺮ از ‪ 1/4‬ﻣﺘﺮ در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪.‬‬

‫‪.5‬‬

‫ﺟﻬﺖ اﺟﺮاي ﻗﺎب ﻓﻠﺰي آﺳﺎﻧﺴﻮردر ﺳﺎزه ﻫﺎي ﺑﺘﻨﻲ‪ ،‬ورﻗﻬﺎي ﻣﺪﻓﻮن در ﺑﺘﻦ در ﭼﻬـﺎر ﮔﻮﺷـﻪ ﻛـﻒ ﭼﺎﻟـﻪ‬

‫آﺳﺎﻧﺴﻮر و ﭘﻴﺮاﻣﻮن ﺑﺎزﺷﻮي آﺳﺎﻧﺴﻮر در ﻃﺒﻘﺎت ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﻮد‪.‬‬ ‫ﻫﻤﺎﻫﻨﮕﻲ ﻧﻘﺸﻪ ﻫﺎي ﺳﺎزه )و ﻓﺎﻳﻠﻬﺎي ﻣﺪل ﻛﺎﻣﭙﻴﻮﺗﺮي ﺳﺎزه( ﺑﺎ ﻣﻌﻤﺎري ﺑﺎﻳﺪ ﺑﻪ دﻗﺖ ﻛﻨﺘﺮل ﮔﺮدد‪ .‬در اﻳﻦ‬ ‫‪.6‬‬ ‫ﻣﺮﺣﻠﻪ ﺑﺎﻳﺪ ﻫﻤﺎﻫﻨﮕﻲ ﻛﺎﻣﻞ ﺑﻴﻦ ﺗﻌﺪاد‪ ،‬ﺷﻤﺎره ﺑﻨﺪي و ﻓﻮاﺻﻞ ﻣﺤﻮرﻫﺎي ﻧﻘﺸﻪ ﺳﺎزه و ﻓﺎﻳﻠﻬﺎي ﻣﺪل ﻛﺎﻣﭙﻴﻮﺗﺮي‬ ‫ﺳﺎزه ﺑﺎ ﻣﺤﻮرﻫﺎي ﻧﻘﺸﻪ ﻣﻌﻤﺎري ﻣﺪ ﻧﻈﺮ ﻗﺮار ﮔﻴﺮد‪ .‬ﻫﻤﭽﻨﻴﻦ ﺗﺮازﻫﺎي ﻃﺒﻘﺎت‪ ،‬ﻣﺤﻞ ﺑﺎزﺷﻮ ﻫﺎ و ﻧﻮرﮔﻴﺮﻫﺎ‪ ،‬ﻋﺮض‬ ‫درز اﻧﻘﻄﺎع‪ ،‬ﺷﻜﻞ‪ ،‬اﺑﻌﺎد و ﺗﺮاز ﺧﺮﭘﺸﺘﻪ و اﺗﺎق ﻛﻨﺘﺮل آﺳﺎﻧﺴﻮر‪ ،‬ﻣﺤﻞ و ﻧﺤﻮه ارﺗﺒﺎط ﭘﻠﻪ ﻫﺎ و راﻣﭗ ﭘﺎرﻛﻴﻨﮓ ﻫﺎ‬ ‫در ﻧﻘﺸﻪ ﻫﺎي ﺳﺎزه و ﻓﺎﻳﻠﻬﺎي ﻣﺪل ﻛﺎﻣﭙﻴﻮﺗﺮي ﺳﺎزه و ﻣﻌﻤﺎري ﺑﺎﻳﺪ ﻫﻤﺎﻫﻨﮓ ﺑﺎﺷﺪ‪.‬‬ ‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫‪.7‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪8 :‬‬

‫در ﺻﻮرﺗﻲ ﻛﻪ ارﺗﻔﺎع ﺧﺎك ﭘﺸﺖ دﻳﻮار زﻳﺮزﻣﻴﻦ ﺑﻴﺶ از ‪ 3/0‬ﻣﺘﺮ ﺑﺎﺷﺪ‪ ،‬ﺑﺎﻳﺪ از دﻳﻮار ﺣﺎﺋﻞ ﺑﺘﻨﻲ ﺑﺮاي‬ ‫ﺗﺤﻤﻞ ﻓﺸﺎر ﺧﺎك اﺳﺘﻔﺎده ﺷﻮد‪ .‬ﺑﺮاي ارﺗﻔﺎع ﻛﻤﺘﺮ از ‪ 3/0‬ﻣﺘﺮ‪ ،‬ﻣﻲ ﺗﻮان از دﻳﻮار آﺟﺮي ‪ 35‬ﺳﺎﻧﺘﻴﻤﺘﺮي اﺳﺘﻔﺎده‬ ‫ﻧﻤﻮد‪ .‬ﺑﻪ ﻫﺮ ﺣﺎل در ﺻﻮرﺗﻲ ﻛﻪ ﺳﺎﺧﺘﻤﺎن داراي ﺑﻴﺶ از ﻳﻚ ﻃﺒﻘﻪ زﻳﺮزﻣﻴﻦ ﺑﺎﺷﺪ‪ ،‬دﻳﻮار آﺟﺮي ‪ 35‬ﺳﺎﻧﺘﻴﻤﺘﺮي‬ ‫ﻓﻘﻂ در زﻳﺮزﻣﻴﻦ ﻧﺨﺴﺖ ﻣﺠﺎز اﺳﺖ و در ﻃﺒﻘﺎت زﻳﺮ آن ﺑﺎﻳﺪ از دﻳﻮار ﺑﺘﻨﻲ ﻣﻨﺎﺳﺐ اﺳﺘﻔﺎده ﺷﻮد‪ .‬ﻣﺤﺎﺳﺒﺎت‬ ‫ﻣﺮﺑﻮط ﺑﻪ ﻓﺸﺎر ﻓﻌﺎل اﺳﺘﺎﺗﻴﻜﻲ و دﻳﻨﺎﻣﻴﻜﻲ ﺧﺎك ﺑﺎﻳﺪ در ﻓﺎﻳﻞ ﺳﺎزه و ﻃﺮاﺣﻲ دﻳﻮارﻫﺎ در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪ .‬ﺗﻮﺟﻪ‬ ‫ﺷﻮد ﻛﻪ در ﻧﺮم اﻓﺰار ‪ ETABS‬ﻃﺮاﺣﻲ دﻳﻮار ﻓﻘﻂ ﺑﺮاي ﺧﻤﺶ در ﺟﻬﺖ ﻗﻮي دﻳﻮار اﻧﺠﺎم ﻣﻲ ﺷﻮد و ﻃﺮاﺣﻲ‬ ‫ﺑﺮاي ﺧﻤﺶ ﺣﻮل ﺿﺨﺎﻣﺖ دﻳﻮار )ﻧﺎﺷﻲ از ﻓﺸﺎر ﺧﺎك( ﺑﺎﻳﺪ ﺑﻪ ﺻﻮرت دﺳﺘﻲ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت اﻧﺠﺎم ﮔﻴﺮد‪.‬‬

‫‪.8‬‬

‫در ﺳﺎزه ﻫﺎي ﺑﺎ ﺳﻴﺴﺘﻢ ﺑﺎرﺑﺮ ﺟﺎﻧﺒﻲ ﻗﺎب ﺧﻤﺸﻲ ﺑﺮاي آﻧﻜﻪ ﺟﺪاﮔﺮﻫﺎي ﻣﻴﺎﻧﻘﺎب ﻣﺎﻧﻌﻲ ﺑﺮاي ﺣﺮﻛﺖ ﻗﺎﺑﻬـﺎ‬ ‫اﻳﺠﺎد ﻧﻜﻨﻨﺪ‪ ،‬ﺟﺰﺋﻴﺎت ﻣﻨﺎﺳﺐ در ﻧﻘﺸﻪ ﻫﺎي ﺳﺎزه اراﺋﻪ ﺷﻮد‪ .‬ﺷﻜﻞ ﻛﻠﻲ زﻳﺮ ﺑﻪ ﻋﻨﻮان راﻫﻨﻤﺎ اراﺋﻪ ﻣﻲ ﺷﻮد‪.‬‬

‫‪.9‬‬

‫در ﻧﻘﺸﻪ ﻫﺎي ﺗﻴﺮرﻳﺰي ﻃﺒﻘﺎت‪ ،‬در ﻣﺤﻠﻬﺎي ﺗﻐﻴﻴﺮ ﺗﺮاز ﻧﻈﻴﺮ رﻣﭗ ﭘﺎرﻛﻴﻨﮕﻬﺎ ﻳﺎ اﺧﺘﻼف ﺗﺮاز ﺳﻄﻮح‪ ،‬ﻣﻘﺎﻃﻊ‬ ‫ﻃﻮﻟﻲ و ﻋﺮﺿﻲ ﻛﺎﻓﻲ ﺟﻬﺖ روﺷﻦ ﺷﺪن ﻧﺤﻮه ﺗﻴﺮرﻳﺰي اراﺋﻪ ﮔﺮدد‪ .‬در ﺳﺎﺧﺘﻤﺎﻧﻬﺎﻳﻲ ﻛﻪ ﻣﻌﻤﺎري آﻧﻬﺎ ﺑﻪ ﺻﻮرت‬ ‫دوﺑﻠﻜﺲ اﺳﺖ‪ ،‬ﻧﻤﺎي ﻣﺤﻞ ﺗﻐﻴﻴﺮ ﺗﺮاز در ﻛﻞ ارﺗﻔﺎع ﺳﺎزه رﺳﻢ ﺷﺪه و ﺗﺮاز ﻛﻠﻴﻪ ﺗﻴﺮﻫﺎ ﺑﻪ وﺿﻮح ﻣﺸﺨﺺ ﺷﻮد‪.‬‬ ‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫‪.10‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪9 :‬‬

‫ﺑﺮاي دﻗﺖ و وﺿﻮح ﺑﻴﺸﺘﺮ ﻧﻘﺸﻪ ﻫﺎ و اﻧﺠﺎم ﭘﻴﺶ ﺑﻴﻨﻲ ﻫﺎي ﻻزم در ﺗﻴﺮرﻳﺰي ﺳﻘﻔﻬﺎ‪ ،‬ﭘﺲ از ﻧﻬﺎﻳﻲ ﺷﺪن‬ ‫ﺑﺎزﺷﻮﻫﺎي ﻣﺮﺑﻮط ﺑﻪ ﺑﺮق و ﺗﺎﺳﻴﺴﺎت‪ ،‬اﻳﻦ ﺑﺎزﺷﻮﻫﺎ ﺑﺮ روي ﻧﻘﺸﻪ ﺳﺎزه ﻧﻴﺰ ﻧﺸﺎن داده ﺷﻮﻧﺪ‪ .‬ﺑﺮاي ﺑﺎزﺷﻮﻫﺎي‬

‫ﺑﺰرگ‪ ،‬در ﭘﻼن ﺗﻴﺮرﻳﺰي ﺗﻴﺮﻫﺎي ﭘﻴﺮاﻣﻮﻧﻲ ﻻزم اﺿﺎﻓﻪ ﺷﻮد‪ .‬ﺑﺮاي ﺑﺎزﺷﻮﻫﺎي ﻛﻮﭼﻚ‪ ،‬ﺟﺰﺋﻴﺎت ﺗﻴﭗ ﺟﻬﺖ اﺟﺮاي‬ ‫ﺳﻘﻒ اراﺋﻪ ﮔﺮدد‪.‬‬ ‫در ﻣﺤﻞ اﺟﺮاي ﻛﻠﻴﻪ ﭘﻠﻪ ﻫﺎ‪ ،‬اﻋﻢ از ورودي ﻫﺎي ﺳﺎﺧﺘﻤﺎن و ارﺗﺒﺎط ﻃﺒﻘﺎت‪ ،‬ﻧﺤﻮه اﺟﺮاي ﺳﺎزه در ﭘﻼن‬ ‫‪.11‬‬ ‫ﻣﺮﺑﻮﻃﻪ ﻣﺸﺨﺺ ﺷﻮد و ﺟﺰﺋﻴﺎت ﻻزم اراﺋﻪ ﮔﺮدد‪ .‬ﻧﺤﻮه اﺟﺮاي ﺗﻴﺮﻫﺎي ﺗﻜﻴﻪ ﮔﺎﻫﻲ ﭘﺎﮔﺮدﻫﺎي ﻣﻴﺎن ﻃﺒﻘﻪ و‬ ‫اﻧﺘﻘﺎل ﺑﺎر آﻧﻬﺎ ﺑﻪ ﺳﺘﻮﻧﻬﺎ ﺑﺎﻳﺪ ﻛﺎﻣﻼ ﻣﺸﺨﺺ ﺑﺎﺷﺪ‪ .‬اﻳﻦ ﻣﻮﺿﻮع ﺑﻪ ﺧﺼﻮص در ﻣﻮرد ﭘﻠﻪ ﻫﺎي داراي ﺑﻴﺶ از دو‬ ‫ﺑﺎزوي ﭘﻠﻪ‪ ،‬ﺑﺎﻳﺪ ﻣﺪ ﻧﻈﺮ ﻗﺮار ﮔﻴﺮد‪.‬‬ ‫‪.12‬‬

‫در ﭘﻼﻧﻬﺎﻳﻲ ﻛﻪ داراي اﺧﺘﻼف ﺗﺮاز ﻫﺴﺘﻨﺪ‪ ،‬در ﭘﻼن ﻗﺎﻟﺐ ﺑﻨﺪي ﻣﺮز ﺗﺮازﻫﺎي ﻣﺠﺎور ﺑﺎ ﺧﻂ ﺿﺨﻴﻢ ﻛﺎﻣﻼ‬

‫ﻣﺸﺨﺺ ﺷﻮد و ﻣﺤﺪوده ﻫﺮ ﺗﺮاز ﺑﺎ ﻳﻚ ﻧﻮع ﻫﺎﺷﻮر ﻣﺸﺨﺺ ﮔﺮدد‪.‬‬ ‫ﺑﺮاي اﺗﺎق ﻛﻨﺘﺮل آﺳﺎﻧﺴﻮر در ﺗﺮاز ﺑﺎﻻي ﺑﺎم‪ ،‬ﻓﻀﺎي ﻛﺎﻓﻲ در ﻧﻘﺸﻪ ﻫﺎي ﺳﺎزه )ﻛﻪ ﺑﺎﻳﺪ در ﻧﻘﺸﻪ ﻣﻌﻤﺎري ﻧﻴﺰ‬ ‫‪.13‬‬ ‫ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﺪه ﺑﺎﺷﺪ( در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﺪه و ﺟﺰﺋﻴﺎت اﺟﺮاي ﺳﻘﻒ و ﺳﺘﻮﻧﻬﺎي ﻣﺮﺑﻮﻃﻪ اراﺋﻪ ﮔﺮدد‪.‬‬ ‫‪.14‬‬

‫در ﺻﻮرت وﺟﻮد اﺳﺘﺨﺮ در ﺳﺎﺧﺘﻤﺎن‪ ،‬آرﻣﺎﺗﻮر ﮔﺬاري ﻛﻒ و دﻳﻮاره آن اراﺋﻪ ﮔﺮدد‪.‬‬

‫‪.15‬‬

‫ﻃﺒﻖ ﺿﻮاﺑﻂ ﻧﺸﺮﻳﻪ ﺷﻤﺎره ‪ 94‬ﻣﻌﺎوﻧﺖ ﺑﺮﻧﺎﻣﻪ رﻳﺰي رﻳﺎﺳﺖ ﺟﻤﻬﻮري‪ ،‬در ﺳﻘﻔﻬﺎي ﺗﻴﺮﭼﻪ ﺑﻠﻮك ﺑﺮاي ﺑﺎر‬ ‫زﻧﺪه ﻛﻤﺘﺮ از ‪ 350 kg / m 2‬و دﻫﺎﻧﻪ ﻛﻤﺘﺮ از ‪ 4‬ﻣﺘﺮ ﻛﻼف ﻣﻴﺎﻧﻲ ﻻزم ﻧﻴﺴﺖ‪ .‬ﺑﺮاي دﻫﺎﻧﻪ ﺑﻴﺸﺘﺮ از ‪ 4‬ﻣﺘﺮ‪ ،‬ﻳﻚ‬ ‫ﻛﻼف ﻣﻴﺎﻧﻲ و در دﻫﺎﻧﻪ ﻫﺎي ‪ 4‬ﺗﺎ ‪ 7‬ﻣﺘﺮ‪ ،‬دو ﻛﻼف ﻋﺮﺿﻲ در ﻳﻚ ﺳﻮم ﻫﺎي دﻫﺎﻧﻪ ﺗﻴﺮﭼﻪ ﺑﺎﻳﺪ ﭘﻴﺶ ﺑﻴﻨﻲ‬ ‫ﮔﺮدد‪ .‬در ﻣﻮرد دﻫﺎﻧﻪ ﻫﺎي ﺑﻴﺶ از ‪ 7‬ﻣﺘﺮ ﻻزم اﺳﺖ ﺳﻪ ﻛﻼف ﻋﺮﺿﻲ در ﻳﻚ ﭼﻬﺎرم ﻫﺎي دﻫﺎﻧﻪ ﺗﻴﺮﭼﻪ ﻫﺎ در‬ ‫ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪ .‬در ﺿﻤﻦ در دﻫﺎﻧﻪ ﻫﺎي ﺑﻴﺶ از ‪ 7‬ﻣﺘﺮ ﺑﺎﻳﺪ ﺣﺘﻤﺎ از ﺗﻴﺮﭼﻪ دوﺑﻞ اﺳﺘﻔﺎده ﺷﻮد‪.‬‬

‫‪.16‬‬

‫در ﺳﻘﻔﻬﺎي ﺗﻴﺮﭼﻪ ﺑﻠﻮك ﻳﺎ دﻳﻮارﻫﺎي ﺟﺪاﻛﻨﻨﺪه‪ ،‬در ﺻﻮرت اﺳﺘﻔﺎده از ﺑﻠﻮك ﻫﺎﻳﻲ از ﻣﻮاد ﭘﻠﻲ اﺳﺘﺎﻳﺮن‪،‬‬ ‫در ﺗﻮﺿﻴﺤﺎت ﻧﻘﺸﻪ ﻫﺎ ذﻛﺮ ﺷﻮد ﻛﻪ ﺟﻨﺲ اﻳﻦ ﺑﻠﻮك ﻫﺎ ﺑﺎﻳﺪ ﻣﻮرد ﺗﺎﻳﻴﺪ ﻣﺮﻛﺰ ﺗﺤﻘﻴﻘﺎت ﻣﺴﻜﻦ ﺑﺎﺷﺪ‪ .‬در‬ ‫ﺿﻤﻦ ﻣﺘﻦ زﻳﺮ ﻛﻪ ﺑﺮﮔﺮﻓﺘﻪ از ﺿﻮاﺑﻂ ﻓﻨﻲ اﻋﻼم ﺷﺪه ﺗﻮﺳﻂ ﻣﺮﻛﺰ ﺗﺤﻘﻴﻘﺎت ﻣﺴﻜﻦ اﺳﺖ در ﻧﻘﺸﻪ ﻫﺎ درج ﺷﻮد‪:‬‬ ‫"از آﻧﺠﺎ ﻛﻪ دﻳﻮارﻫﺎي ﺑﻴﻦ واﺣﺪﻫﺎي ﻣﺴﺘﻘﻞ )ﻣﺎﻧﻨﺪ دﻳﻮار ﺑﻴﻦ آﭘﺎرﺗﻤﺎﻧﻬﺎي ﻣﺴﻜﻮﻧﻲ ﻳﺎ واﺣﺪﻫﺎي ﺗﺠﺎري‪ ،‬اداري ﻣﺴﺘﻘﻞ‬ ‫و ﻏﻴﺮه( در ﻫﺮ ﺳﺎﺧﺘﻤﺎن ﺑﺎﻳﺪ داراي ﻣﻘﺎوﻣﺖ در ﺑﺮاﺑﺮ آﺗﺶ ﺑﺎﺷﻨﺪ‪ ،‬در اﻳﻦ ﻣﺤﻞ ﻫﺎ ﺑﺎﻳﺪ ﺑﻠﻮك ﻫﺎي ﭘﻠﻲ اﺳﺘﺎﻳﺮن ﻗﻄﻊ‬ ‫ﺷﺪه و دﻳﻮارﻫﺎ ﺗﺎ زﻳﺮ ﺳﻘﻒ ﺳﺎزه اي )ﻳﻌﻨﻲ زﻳﺮ ﺗﻴﺮﭼﻪ ﻳﺎ ﺑﺘﻦ( اﻣﺘﺪاد داﺷﺘﻪ ﺑﺎﺷﻨﺪ ﻳﺎ ﺑﻪ ﻃﻮر ﻣﻨﺎﺳﺐ از ﻣﺼﺎﻟﺢ ﺣﺮﻳﻖ‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪10 :‬‬

‫ﺑﻨﺪ اﺳﺘﻔﺎده ﺷﻮد‪ ،‬ﺑﻪ ﮔﻮﻧﻪ اي ﻛﻪ ﺑﻠﻮك ﻫﺎي ﭘﻠﻲ اﺳﺘﺎﻳﺮن در اﻳﻦ ﻗﺴﻤﺘﻬﺎ ﺑﻴﻦ دو واﺣﺪ ﻣﺠﺎور ﭘﻴﻮﺳﺘﮕﻲ ﻧﺪاﺷﺘﻪ ﺑﺎﺷﻨﺪ و‬ ‫از ﮔﺴﺘﺮش ﻫﺮ ﮔﻮﻧﻪ ﺣﺮﻳﻖ اﺣﺘﻤﺎﻟﻲ ﺑﻴﻦ دو ﻓﻀﺎﻳﻲ ﻛﻪ ﺑﻪ وﺳﻴﻠﻪ دﻳﻮار ﻣﻘﺎوم در ﺑﺮاﺑﺮ آﺗﺶ از ﻳﻜﺪﻳﮕﺮ ﺟﺪا ﺷﺪه اﻧﺪ‪،‬‬ ‫ﺟﻠﻮﮔﻴﺮي ﮔﺮدد‪ .‬ﺑﺮش و ﺣﺬف ﭘﻠﻲ اﺳﺘﺎﻳﺮن در اﻳﻦ ﻗﺴﻤﺖ ﻫﺎ ﻣﻲ ﺗﻮاﻧﺪ ﺑﻪ دو روش زﻳﺮ ﺻﻮرت ﮔﻴﺮد‪:‬‬ ‫•‬

‫ﭘﺲ از ﺑﺘﻦ رﻳﺰي و ﭘﻴﺶ از راﺑﻴﺘﺲ ﺑﻨﺪي ﻣﻮرد ﻧﻴﺎز ﺑﺮاي ﺳﻘﻒ‬

‫• در ﻧﻈﺮ ﮔﺮﻓﺘﻦ ﺗﻤﻬﻴﺪاﺗﻲ در ﻗﺎﻟﺐ ﺑﻨﺪي ﺳﻘﻒ‪ ،‬ﭘﻴﺶ از ﺑﺘﻦ رﻳﺰي"‬

‫ﻋﻼوه ﺑﺮ ﻣﻮارد ﻓﻮق‪ ،‬ﻃﺒﻖ اﻋﻼم ﻣﺮﻛﺰ ﺗﺤﻘﻴﻘﺎت ﻣﺴﻜﻦ اﺗﺼﺎل ﻣﺴﺘﻘﻴﻢ ﻧﺎزك ﻛﺎري ﺑﻪ ﺑﻠﻮك ﭘﻠﻲ اﺳﺘﺎﻳﺮن ﻣﻤﻨﻮع‬ ‫اﺳﺖ و ﺑﺎﻳﺪ ﺑﺮاي ﻧﺎزك ﻛﺎري ﺳﻘﻒ‪ ،‬از ﺳﻘﻒ ﻛﺎذب ﺑﺎ اﺗﺼﺎل ﻣﻜﺎﻧﻴﻜﻲ ﺑﻪ ﺳﻘﻒ ﺳﺎزه اي اﺳﺘﻔﺎده ﺷﻮد و ﺣﺪاﻗﻞ‬ ‫‪ 1/5‬ﺳﺎﻧﺘﻴﻤﺘﺮ اﻧﺪود ﮔﭽﻲ ﺑﺮ روي ﺳﻘﻒ ﻛﺎذب اﺟﺮا ﺷﻮد‪ .‬ﺑﻪ اﻳﻦ ﻣﻨﻈﻮر ﻳﻚ ﻧﻤﻮﻧﻪ ﺟﺰﺋﻴﺎت ﻣﻮرد ﺗﺎﻳﻴﺪ اﻳﻦ ﻣﺮﻛﺰ‬ ‫در ﺷﻜﻞ زﻳﺮ ﺑﻪ ﻋﻨﻮان راﻫﻨﻤﺎ اراﺋﻪ ﻣﻴﺸﻮد‪:‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫‪.17‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪11 :‬‬

‫در ﺻﻮرت ﻧﺼﺐ ﻫﺮﮔﻮﻧﻪ ﺗﺠﻬﻴﺰات در ارﺗﺒﺎط ﺑﺎ ﺗﺎﺳﻴﺴﺎت ﺑﺮق و ﻣﻜﺎﻧﻴﻚ ﻧﻈﻴﺮ ﭼﻴﻠﺮﻫﺎ‪ ،‬ﻣﻨﺎﺑﻊ آب‪ ،‬دﻳﺰل‬ ‫ژﻧﺮاﺗﻮر‪ ،‬ﻓﻦ ﻫﺎ‪ ،‬ﺑﺮج ﻫﺎي ﺧﻨﻚ ﻛﻦ‪ ،‬ﭘﻤﭗ ﻫﺎ و ‪ ....‬ﺑﺮ روي ﺑﺎم ﻳﺎ ﻫﺮ ﺳﻘﻒ ﺳﺎزه اي دﻳﮕﺮ‪ ،‬ﺑﺎرﻫﺎي‬ ‫اﺳﺘﺎﺗﻴﻜﻲ و دﻳﻨﺎﻣﻴﻜﻲ ﻧﺎﺷﻲ از ﻛﺎرﻛﺮد ﺗﺠﻬﻴﺰات ﻳﺎ ارﺗﻌﺎﺷﺎت زﻟﺰﻟﻪ در ﻃﺮاﺣﻲ ﺳﺎزه در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد و در‬ ‫ﻧﻘﺸﻪ ﻫﺎي ﺳﺎزه ﺟﺰﺋﻴﺎت ﻻزم ﺑﺮاي ﻣﺤﻞ ﻧﺼﺐ اﻳﻦ ﺗﺠﻬﻴﺰات ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﻮد‪.‬‬

‫‪.18‬‬

‫در ﺻﻮرﺗﻲ ﻛﻪ ﻋﺒﻮر ﺑﺰرﮔﺘﺮﻳﻦ دﺳﺘﮕﺎه ﺗﺎﺳﻴﺴﺎت ﻣﻜﺎﻧﻴﻚ و ﺑﺮق ﻧﻈﻴﺮ ﭼﻴﻠﺮ‪ ،‬ﻣﻨﺎﺑﻊ ﻛﻮﻳﻞ دار‪ ،‬دﻳﺰل‬ ‫ژﻧﺮاﺗﻮر و ‪ ....‬از درﺑﻬﺎي ﺳﺎﺧﺘﻤﺎن )ﻣﺴﻴﺮ ورودي ﺳﺎﺧﺘﻤﺎن ﺗﺎ داﺧﻞ ﻓﻀﺎي ﻣﻮرد ﻧﻈﺮ ﺑﺮاي ﻧﺼﺐ دﺳﺘﮕﺎه( اﻣﻜﺎن‬ ‫ﭘﺬﻳﺮ ﻧﺒﺎﺷﺪ‪ ،‬ﺑﺎﻳﺪ در ﻧﻘﺸﻪ ﻫﺎي ﺳﺎزه ﺑﺮاي ﻓﻀﺎي ﻣﻮرد ﻧﻈﺮ ﺑﺮاي ﻧﺼﺐ دﺳﺘﮕﺎه‪ ،‬ﺳﻘﻔﻲ ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﻮد ﻛﻪ اﻣﻜﺎن‬ ‫ﺟﺎﺑﺠﺎﻳﻲ آن در زﻣﺎن ﻧﺼﺐ و ﻳﺎ ﺗﻌﻤﻴﺮات اﺣﺘﻤﺎﻟﻲ وﺟﻮد داﺷﺘﻪ ﺑﺎﺷﺪ‪ .‬ﻣﻌﻤﻮﻻ اﺳﺘﻔﺎده از ﺳﻘﻒ ﻣﺘﺸﻜﻞ از ﺗﻴﺮﭼﻪ‬ ‫ﻫﺎي ﻓﻠﺰي )ﺑﺎ اﺗﺼﺎﻻت ﭘﻴﭽﻲ( و ورق ﻓﻮﻻدي ﺑﺮاي ﭘﻮﺷﺶ ﺳﻘﻒ ﻣﻨﺎﺳﺐ ﺧﻮاﻫﺪ ﺑﻮد‪.‬‬

‫‪.19‬‬

‫ﻣﻄﺎﺑﻖ ﺷﻜﻞ زﻳﺮ ﺑﺎﻳﺪ ﺟﻬﺖ ﺟﻠﻮﮔﻴﺮي از ﺷﺎﻧﻪ ﮔﻴﺮ ﺷﺪن ﻣﺴﻴﺮ ﺗﺮدد در راه ﭘﻠﻪ ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ اﻟﺰاﻣﺎت ﻣﻌﻤﺎري‪،‬‬ ‫ﺣﺪاﻗﻞ ﻓﺎﺻﻠﻪ ﺑﻴﻦ ﺗﻴﺮﻫﺎي ﺳﺎزه در ﻃﺮﻓﻴﻦ ﭘﻠﻪ ﻫﺎ ﺑﻪ ﻣﻴﺰان ‪ 240‬ﺳﺎﻧﺘﻴﻤﺘﺮ رﻋﺎﻳﺖ ﺷﻮد‪.‬‬

‫‪Beam‬‬

‫‪Beam‬‬

‫‪Beam‬‬ ‫‪Min. 240 cm‬‬

‫‪Beam‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫‪.20‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪12 :‬‬

‫در ﺳﺎزه ﻫﺎي ﺑﺘﻨﻲ در ﺗﺮﺳﻴﻢ ﭘﻼﻧﻬﺎي ﻗﺎﻟﺐ ﺑﻨﺪي )ﺗﻴﺮرﻳﺰي ﻃﺒﻘﺎت( ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﻓﻘﻂ ﺧﻄﻮط ﭘﻴﺮاﻣﻮن‬ ‫ﭘﻼن و ﺧﻄﻮﻃﻲ ﻛﻪ در ﻟﺒﻪ ﺑﺎزﺷﻮ ﻗﺮار دارﻧﺪ ﺑﻪ ﺻﻮرت ﺧﻂ ﭘﻴﻮﺳﺘﻪ دﻳﺪه ﺷﻮﻧﺪ و ﺧﻄﻮط دﻳﮕﺮ ﻣﺮﺑﻮط ﺑﻪ ﺗﻴﺮﻫﺎ‪،‬‬ ‫ﺑﻪ ﻋﻠﺖ ﻗﺮار ﮔﺮﻓﺘﻦ در ﭘﺸﺖ دال ﺑﺎﻳﺪ ﺑﻪ ﺻﻮرت ﺧﻂ ﭼﻴﻦ ﻧﺸﺎن داده ﺷﻮﻧﺪ‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪13 :‬‬

‫‪ -5‬ﻧﻜﺎت ﺣﺎﺋﺰ اﻫﻤﻴﺖ در ﺟﺰﺋﻴﺎت ﺳﺎزه ﻫﺎي ﺑﺘﻨﻲ‬

‫‪ .1‬ﺣﺪاﻗﻞ ﻃﻮل وﺻﻠﻪ در ﺗﻴﺮﻫﺎ‪ ،‬ﺳﺘﻮﻧﻬﺎ و داﻟﻬﺎ‪ 55 ،‬ﺑﺮاﺑﺮ ﻗﻄﺮ آرﻣﺎﺗﻮر رﻋﺎﻳﺖ ﮔﺮدد‪ .‬در ﺻﻮرﺗﻲ ﻛﻪ ﻃﻮل وﺻﻠﻪ ﻛﻤﺘﺮ‬ ‫از اﻳﻦ ﻣﻘﺪار ﺑﺎﺷﺪ‪ ،‬ﻣﺤﺎﺳﺒﺎت ﻣﺮﺑﻮﻃﻪ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت اﺿﺎﻓﻪ ﺷﻮد‪.‬‬ ‫‪ .2‬در ﺳﺘﻮﻧﻬﺎي ﻗﺎﺑﻬﺎي ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي ﻣﺘﻮﺳﻂ و زﻳﺎد‪ ،‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﺣﺪاﻛﺜﺮ ﻧﺴﺒﺖ آرﻣﺎﺗﻮر ﻃﻮﻟﻲ در ﻣﺤﻞ وﺻﻠﻪ‬ ‫ﺑﻪ ‪ %6‬ﻣﺤﺪود ﮔﺮدد‪ .‬ﻟﺬا در ﺻﻮرﺗﻲ ﻛﻪ ﻧﺴﺒﺖ آرﻣﺎﺗﻮر ﺳﺘﻮن ﺑﻴﺶ از ‪ %3‬ﺑﺎﺷﺪ‪ ،‬ﺑﺎﻳﺪ آرﻣﺎﺗﻮرﻫﺎي ﻣﻘﻄﻊ‪ ،‬در ﻃﻮل‬ ‫ﺳﺘﻮن در ﻣﺤﻠﻬﺎي ﻣﺘﻔﺎوت وﺻﻠﻪ ﺷﻮﻧﺪ ﺑﻪ ﻧﺤﻮي ﻛﻪ در ﻫﺮ ﻣﻘﻄﻊ ﺳﺘﻮن‪ ،‬ﻧﺴﺒﺖ آرﻣﺎﺗﻮر از ‪ %6‬ﻓﺮاﺗﺮ ﻧﺒﺎﺷﺪ‪.‬‬ ‫‪ .3‬ﻃﺒﻖ ﺑﻨﺪ ﻫﺎي ‪ 7-2-2-3-20-9‬و ‪ 10-3-2-4-20-9‬در ﻗﺎﺑﻬﺎي ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي ﻣﺘﻮﺳﻂ و زﻳﺎد‪ ،‬در ﻣﺤﻞ‬ ‫اﺗﺼﺎل ﺳﺘﻮن ﺑﻪ ﺷﺎﻟﻮده‪ ،‬ﺑﺎﻳﺪ آرﻣﺎﺗﻮر ﻋﺮﺿﻲ ﺣﺪاﻗﻞ در ﻃﻮل ‪ 300‬ﻣﻴﻠﻴﻤﺘﺮ در ﺷﺎﻟﻮده اداﻣﻪ ﻳﺎﺑﺪ‪ .‬ﻫﻤﭽﻨﻴﻦ در‬ ‫ﻗﺴﻤﺖ ﻫﺎي ﺧﺎرج از ﻧﺎﺣﻴﻪ ﺑﺤﺮاﻧﻲ ﺳﺘﻮﻧﻬﺎ )ﻣﺤﺪوده ﻣﻴﺎﻧﻲ ﺳﺘﻮﻧﻬﺎ( ﻃﺒﻖ ﺑﻨﺪ ‪ 1-4-6-12-9‬ﺣﺪاﻛﺜﺮ ﻓﺎﺻﻠﻪ ﺑﻴﻦ‬ ‫آرﻣﺎﺗﻮرﻫﺎي ﻋﺮﺿﻲ ﺳﺘﻮن ﺑﻪ ‪ d/2‬ﻣﺤﺪود ﻣﻴﺸﻮد‪.‬‬ ‫‪ .4‬در ﻣﻮرد آرﻣﺎﺗﻮر ﻋﺮﺿﻲ ﺗﻴﺮﻫﺎ در ﻗﺎﺑﻬﺎي ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي ﻣﺘﻮﺳﻂ و زﻳﺎد‪ ،‬ﺣﺪاﻗﻞ ﻃﻮل "دو ﺑﺮاﺑﺮ ارﺗﻔﺎع ﺗﻴﺮ"‬ ‫ﺑﺮاي آرﻣﺎﺗﻮرﮔﺬاري ﻋﺮﺿﻲ وﻳﮋه ﻛﻨﺘﺮل ﺷﻮد‪ .‬ﻫﻤﭽﻨﻴﻦ ﺣﺪاﻛﺜﺮ ﻓﺎﺻﻠﻪ ﻣﺠﺎز آرﻣﺎﺗﻮرﻫﺎي ﻋﺮﺿﻲ در اﻳﻦ ﻧﺎﺣﻴﻪ ﺑﺮاﺑﺮ‬ ‫ﻳﻚ ﭼﻬﺎرم ارﺗﻔﺎع ﻣﻮﺛﺮ ﺗﻴﺮ )‪ (d‬در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد و ﻓﺎﺻﻠﻪ اوﻟﻴﻦ آرﻣﺎﺗﻮر ﻋﺮﺿﻲ از ﺑﺮ ﺳﺘﻮن ﺑﻴﺶ از ‪5‬‬ ‫ﺳﺎﻧﺘﻴﻤﺘﺮ ﻧﺒﺎﺷﺪ‪.‬‬ ‫‪ .5‬در ﻣﻮرد ﺗﻴﺮﻫﺎي اﺻﻠﻲ ﻛﻪ ﺗﻴﺮﻫﺎي ﻓﺮﻋﻲ ﺑﺎ ﺑﺎر ﻗﺎﺑﻞ ﺗﻮﺟﻪ ﺑﻪ ﺻﻮرت ﺗﻮدﻟﻲ ﺑﻪ آﻧﻬﺎ ﻣﺘﺼﻞ ﻣﻴﺸﻮﻧﺪ‪ ،‬ﺑﺎﻳﺪ آرﻣﺎﺗﻮر‬ ‫ﭘﻴﭽﺸﻲ ﻃﻮﻟﻲ و ﻋﺮﺿﻲ ﻣﺤﺎﺳﺒﻪ ﺷﺪه ﺗﻮﺳﻂ ﻧﺮم اﻓﺰار ﺑﻪ ﻃﻮر ﻣﻨﺎﺳﺐ ﺑﺎ آرﻣﺎﺗﻮرﻫﺎي ﺧﻤﺸﻲ و ﺑﺮﺷﻲ ﺗﻴﺮﻫﺎي‬ ‫اﺻﻠﻲ ﺗﺮﻛﻴﺐ ﺷﺪه و در ﻧﻘﺸﻪ ﻫﺎ درج ﺷﻮد‪ .‬در ﻣﻮرد ﺟﺰﺋﻴﺎت ﻃﺮاﺣﻲ و ﻧﺤﻮه ﺗﺮﻛﻴﺐ آرﻣﺎﺗﻮرﻫﺎ و ﭼﻴﺪﻣﺎن آﻧﻬﺎ در‬ ‫ﻣﻘﻄﻊ‪ ،‬ﺗﻮﺟﻪ ﺑﻪ ﺑﺨﺸﻬﺎي ‪ 7-12-9‬ﺗﺎ ‪ 12-12-9‬ﻣﺒﺤﺚ ﻧﻬﻢ ﻻزم اﺳﺖ‪ .‬ﻃﺒﻖ ﺑﻨﺪﻫﺎي ‪1-9-12-9 ،3-8-12-9‬‬ ‫و ‪ 1-12-12-9‬ﺑﺎﻳﺪ آرﻣﺎﺗﻮر ﭘﻴﭽﺸﻲ ﻃﻮﻟﻲ ﺑﻪ ﻃﻮر ﻳﻜﻨﻮاﺧﺖ دور ﺗﺎ دور ﻣﻘﻄﻊ ﺗﻮزﻳﻊ ﺷﺪه و ﺗﺮﻛﻴﺐ آرﻣﺎﺗﻮر‬ ‫ﭘﻴﭽﺸﻲ )ﻃﻮﻟﻲ و ﻋﺮﺿﻲ( ﺑﺎ آرﻣﺎﺗﻮر ﺧﻤﺸﻲ و ﺑﺮﺷﻲ اﻧﺠﺎم ﺷﻮد‪.‬‬ ‫‪ .6‬در ﻣﻮرد ﺗﻐﻴﻴﺮ ﻣﻘﻄﻊ ﺳﺘﻮﻧﻬﺎي ﺑﺘﻨﻲ ﻛﻪ در ﻧﻤﺎ ﻗﺮار ﻣﻴﮕﻴﺮﻧﺪ‪ ،‬ﺑﺎﻳﺪ ﻛﻮﭼـﻚ ﺷـﺪن ﺳـﺘﻮن ﻓﻘـﻂ از ﺳـﻤﺖ داﺧـﻞ‬ ‫ﺳﺎﺧﺘﻤﺎن اﻧﺠﺎم ﺷﻮد‪ .‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺑﺨﺶ ‪ 12-11-9‬ﻣﺒﺤﺚ ﻧﻬﻢ‪ ،‬در ﺻﻮرﺗﻲ ﻛﻪ ﻣﻴﺰان ﻋﻘﺐ ﻧﺸﻴﻨﻲ ﻣﻘﻄﻊ ﺳﺘﻮن از‬ ‫ﻳﻚ ﺳﻤﺖ ﺑﻴﺶ از ‪ 75‬ﻣﻴﻠﻴﻤﺘﺮ ﺑﺎﺷﺪ ﻳﺎ ﺷﻴﺐ ﻣﻼﻳﻢ ﺗﺮ از ‪ 1‬ﺑﻪ ‪ 6‬ﺑﺮاي ﻣﻴﻠﮕﺮد ﻃﻮﻟﻲ ﺳﺘﻮن ﺗﺎﻣﻴﻦ ﻧﺸﻮد ﺑﺎﻳﺪ در‬ ‫ﻣﺤﻞ ﻋﻘﺐ ﻧﺸﻴﻨﻲ آرﻣﺎﺗﻮر ﺳﺘﻮن ﭘﺎﻳﻴﻨﻲ ﺑﺎ ﺧﻢ اﺳﺘﺎﻧﺪارد ﻣﻬﺎر ﺷﻮد و ﺑﺮاي ﺳﺘﻮن ﺑﺎﻻﻳﻲ آرﻣﺎﺗﻮر اﻧﺘﻈﺎر در ﺳـﺘﻮن‬ ‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪14 :‬‬

‫ﭘﺎﻳﻴﻨﻲ ﭘﻴﺶ ﺑﻴﻨﻲ ﺷﻮد‪ .‬در ﻣﻮرد ﺳﺘﻮﻧﻬﺎي ﻣﻴﺎﻧﻲ ﻧﻴﺰ ﻛﻪ ﻛﻮﭼـﻚ ﺷـﺪن ﻣﻘﻄـﻊ از دو ﻃـﺮف اﻧﺠـﺎم ﻣﻴﮕﻴـﺮد‪ ،‬در‬ ‫ﺻﻮرﺗﻲ ﻛﻪ ﺷﺮاﻳﻂ ﻓﻮق ﺑﺮﻗﺮار ﺑﺎﺷﺪ‪ ،‬ﺑﺎﻳﺪ آرﻣﺎﺗﻮرﺑﻨﺪي ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ اﻳﻦ ﺟﺰﺋﻴﺎت رﺳﻢ ﺷﻮد‪ .‬ﻟﻄﻔﺎ ﺑﻪ ﺷﻜﻞ ﻫﺎي ذﻳﻞ‬ ‫ﺗﻮﺟﻪ ﺷﻮد‪:‬‬

‫‪ .7‬ﺑﺮاي ﺗﻴﺮﻫﺎي ﺑﺎ دﻫﺎﻧﻪ ﻛﻮﺗﺎه در ﻗﺎﺑﻬﺎي ﺷﻜﻞ ﭘﺬﻳﺮ ﻣﺘﻮﺳﻂ و زﻳﺎد‪ ،‬ﺗﻮﺟـﻪ ﺷـﻮد ﻛـﻪ ﻃﺒـﻖ ﺑﻨـﺪ ‪1-1-1-3-20-9‬‬ ‫ﻣﺒﺤﺚ ﻧﻬﻢ‪ ،‬ﺣﺪاﻛﺜﺮ ﻣﻘﺪار ﻋﻤﻖ ﻣﻮﺛﺮ ﺗﻴﺮ ﺑﺎﻳﺪ ﺑﻪ ﻳﻚ ﭼﻬﺎرم دﻫﺎﻧﻪ آزاد ﺗﻴﺮ ﻣﺤﺪود ﺷﻮد‪ .‬ﻫﻤﭽﻨـﻴﻦ ﺑـﻪ ﻋﻠـﺖ‬ ‫ﻃﻮل ﻛﻮﺗﺎه اﻳﻦ دﻫﺎﻧﻪ ﻫﺎ‪ ،‬ﻧﻴﺮوي ﺑﺮﺷﻲ ﺣﺎﺻﻞ از زﻟﺰﻟﻪ در اﻳﻦ دﻫﺎﻧﻪ ﻫـﺎ ﻧﺴـﺒﺖ ﺑـﻪ دﻳﮕـﺮ ﺗﻴﺮﻫـﺎ ﺑﻴﺸـﺘﺮ ﺑـﻮده و‬ ‫آرﻣﺎﺗﻮر ﺑﺮﺷﻲ ﻣﻮرد ﻧﻴﺎز ﻧﺴﺒﺖ ﺑﻪ دﻳﮕﺮ ﺗﻴﺮﻫﺎ ﺑﻴﺸﺘﺮ ﺧﻮاﻫﺪ ﺑﻮد ﻛﻪ ﺗﻮﺟﻪ ﻃﺮاح ﺳﺎزه ﺑﻪ آن ﺿﺮوري اﺳﺖ‪.‬‬ ‫‪ .8‬در ﺗﻴﺮﻫﺎي ﻗﺎب ﻫﺎي ﺧﻤﺸﻲ ﺑﺘﻨﻲ ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي ﻣﺘﻮﺳﻂ و زﻳﺎد‪ ،‬ﻃﺒﻖ ﺑﻨـﺪﻫﺎي ‪ 2-2-1-3-20-9‬و ‪-4-20-9‬‬ ‫‪ 2-2-1‬ﺑﺎﻳﺪ در ﺑﺮ ﺳﺘﻮن ﻣﻘﺎوﻣﺖ ﻟﻨﮕﺮ ﺧﻤﺸﻲ ﻣﺜﺒﺖ ﺣﺪاﻗﻞ ﺑﻪ ﻣﻴﺰان ﻧﺼﻒ ﻣﻘﺎوﻣﺖ ﻟﻨﮕﺮ ﺧﻤﺸﻲ ﻣﻨﻔﻲ ﺗﺎﻣﻴﻦ‬ ‫ﺷﻮد‪ .‬ﺑﻪ اﻳﻦ ﻣﻨﻈﻮر ﻻزم اﺳﺖ در ﺑﺮ ﺳﺘﻮﻧﻬﺎ ﻣﻘﺪار آرﻣﺎﺗﻮر ﺗﺤﺘﺎﻧﻲ )آرﻣﺎﺗﻮر ﻓﺸﺎري( ﻛﻤﺘﺮ از ﻧﺼﻒ آرﻣﺎﺗﻮر ﻓﻮﻗـﺎﻧﻲ‬ ‫)آرﻣﺎﺗﻮر ﻛﺸﺸﻲ( ﻧﺒﺎﺷﺪ‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪15 :‬‬

‫‪ .9‬در ﺗﻴﺮﻫﺎي ﻗﺎب ﻫﺎي ﺧﻤﺸﻲ ﺑﺘﻨﻲ ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي ﻣﺘﻮﺳﻂ و زﻳﺎد‪ ،‬ﻃﺒﻖ ﺑﻨـﺪﻫﺎي ‪ 2-2-1-3-20-9‬و ‪-4-20-9‬‬ ‫‪ 3-2-1‬ﺑﺎﻳﺪ ﺣﺪاﻗﻞ ﻳﻚ ﭼﻬﺎرم آرﻣﺎﺗﻮر ﻣﻮﺟﻮد در ﻣﻘﺎﻃﻊ ﺑﺮ ﺗﻜﻴﻪ ﮔﺎه ﻫﺎ‪) ،‬ﻫﺮ اﻧﺘﻬﺎ ﻛـﻪ آرﻣـﺎﺗﻮر ﺑﻴﺸـﺘﺮي دارد(‬ ‫در ﺳﺮاﺳﺮ ﻃﻮل ﺗﻴﺮ اداﻣﻪ داﺷﺘﻪ ﺑﺎﺷﻨﺪ‪.‬‬ ‫‪ .10‬در ﻣﻘﺎﻃﻊ ﺗﻴﺮﻫﺎ‪ ،‬ﺣﺪاﻗﻞ ﻓﻮاﺻﻞ آزاد ﺑﻴﻦ ﻣﻴﻠﮕﺮدﻫﺎ ﻃﺒﻖ ﺑﺨﺶ ‪ 11-11-9‬ﻣﺒﺤﺚ ﻧﻬﻢ رﻋﺎﻳﺖ ﮔﺮدد‪ .‬راﺑﻄﻪ‬ ‫ﺗﻘﺮﻳﺒﻲ زﻳﺮ ﺑﻪ ﻋﻨﻮان راﻫﻨﻤﺎ ﭘﻴﺸﻨﻬﺎد ﻣﻲ ﺷﻮد‪:‬‬ ‫])‪n = Integer[(b - 65)/(2d b + 35‬‬

‫‪ : b‬ﻋﺮض ﺗﻴﺮ ﺑﺮ ﺣﺴﺐ ﻣﻴﻠﻴﻤﺘﺮ‬ ‫‪ : db‬ﻗﻄﺮ ﻣﻴﻠﮕﺮد ﻃﻮﻟﻲ ﺑﺮ ﺣﺴﺐ ﻣﻴﻠﻴﻤﺘﺮ‬ ‫‪ : n‬ﺣﺪاﻛﺜﺮ ﺗﻌﺪاد ﻣﻴﻠﮕﺮد ﺑﺎ اﺣﺘﺴﺎب ﻣﻴﻠﮕﺮدﻫﺎي ﺳﺮاﺳﺮي و ﺗﻘﻮﻳﺘﻲ‬

‫راﺑﻄﻪ ﻓﻮق درﺣﺎﻟﺖ وﺻﻠﻪ ﺷﺪن ﻛﻠﻴﻪ ﻣﻴﻠﮕﺮدﻫﺎ ﺑﻪ دﺳﺖ آﻣﺪه اﺳﺖ‪ .‬در ﺻﻮرﺗﻲ ﻛﻪ ﻃﻮل ﺗﻴﺮ ﺑﻪ ﻧﺤﻮي ﺑﺎﺷﺪ ﻛﻪ‬ ‫اﺣﺘﻴﺎج ﺑﻪ وﺻﻠﻪ ﻧﺪاﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ﺣﺪاﻛﺜﺮ ﺗﻌﺪاد ﻣﻴﻠﮕﺮدﻫﺎ ﻗﺎﺑﻞ اﻓﺰاﻳﺶ ﺧﻮاﻫﺪ ﺑﻮد‪ .‬ﺑﻪ ﻫﺮ ﺣﺎل‪ ،‬در ﻣﻮاردي ﻛﻪ ﺗﻌﺪاد‬ ‫ﻣﻴﻠﮕﺮد ﻣﻮرد ﻧﻴﺎز ﺑﻴﺸﺘﺮ از ﺣﺪاﻛﺜﺮ ﺗﻌﺪاد ﻣﺠﺎز ﻣﻴﻠﮕﺮد ﺑﺎﺷﺪ‪ ،‬ﺑﺎﻳﺪ آرﻣﺎﺗﻮرﻫﺎ در دو ﻳﺎ ﭼﻨﺪ ﺳﻔﺮه ﭼﻴﺪه ﺷﻮﻧﺪ‪ .‬در‬ ‫اﻳﻦ ﺣﺎﻟﺖ ﺣﺪاﻗﻞ ﻓﺎﺻﻠﻪ ﻻزم ﺑﻴﻦ ﺳﻔﺮه ﻫﺎي ﻣﺘﻮاﻟﻲ‪ ،‬ﻃﺒﻖ ﺑﻨﺪ ‪ 3-1-11-11-9‬ﺑﺎﻳﺪ ﺑﺮاﺑﺮ ﺣﺪاﻛﺜﺮ دو ﻣﻘﺪار‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪16 :‬‬

‫‪ 25‬ﻣﻴﻠﻴﻤﺘﺮ و ﺑﺰرﮔﺘﺮﻳﻦ ﻗﻄﺮ ﻣﻴﻠﮕﺮد ﻃﻮﻟﻲ ﺑﺎﺷﺪ‪ .‬در ﻓﺎﻳﻞ ﻛﺎﻣﭙﻴﻮﺗﺮي ﺳﺎزه ﻧﻴﺰ ﺑﺎﻳﺪ ﻣﻘﺪار ﭘﻮﺷﺶ ﺑﺘﻨﻲ‬ ‫ﺗﻴﺮﻫﺎ ﻣﺘﻨﺎﺳﺐ ﺑﺎ ﺗﻌﺪاد ﺳﻔﺮه ﻫﺎي ﻣﻴﻠﮕﺮد اﻓﺰاﻳﺶ ﻳﺎﺑﺪ ﺑﻪ ﻧﺤﻮي ﻛﻪ ﻧﺸﺎن دﻫﻨﺪه ﻣﺮﻛﺰ ﺳﻄﺢ ﺗﻘﺮﻳﺒﻲ ﻣﺠﻤﻮﻋﻪ‬ ‫ﻣﻴﻠﮕﺮدﻫﺎ ﺑﺎﺷﺪ‪ .‬ﺟﺰﺋﻴﺎت ﻣﻮرد ﻧﻈﺮ در ﺷﻜﻞ ﻫﺎي ﻓﻮق ﻧﺸﺎن داده ﺷﺪه اﺳﺖ‪.‬‬ ‫‪ .11‬در ﻣﻘﺎﻃﻊ ﺳﺘﻮﻧﻬﺎ‪ ،‬ﺣﺪاﻗﻞ ﻓﻮاﺻﻞ آزاد ﺑﻴﻦ ﻣﻴﻠﮕﺮدﻫﺎ ﻃﺒﻖ ﺑﺨﺶ ‪ 11-11-9‬ﻣﺒﺤﺚ ﻧﻬﻢ رﻋﺎﻳﺖ ﮔﺮدد‪ .‬راﺑﻄﻪ‬ ‫ﺗﻘﺮﻳﺒﻲ زﻳﺮ ﺑﻪ ﻋﻨﻮان راﻫﻨﻤﺎ ﭘﻴﺸﻨﻬﺎد ﻣﻲ ﺷﻮد‪:‬‬ ‫])‪n = Integer[(c - 55)/(2d b + 40‬‬

‫‪ : c‬ﻋﺮض ﺳﺘﻮن ﺑﺮ ﺣﺴﺐ ﻣﻴﻠﻴﻤﺘﺮ‬ ‫‪ : db‬ﻗﻄﺮ ﻣﻴﻠﮕﺮد ﻃﻮﻟﻲ ﺳﺘﻮن ﺑﺮ ﺣﺴﺐ ﻣﻴﻠﻴﻤﺘﺮ‬ ‫‪ : n‬ﺣﺪاﻛﺜﺮ ﺗﻌﺪاد ﻣﻴﻠﮕﺮد در ﺿﻠﻊ ﺳﺘﻮن ﺑﻪ ﻋﺮض ‪c‬‬ ‫‪ .12‬در ﻣﻮرد ﺗﻴﺮﻫﺎﻳﻲ ﻛﻪ ﻋﺮض آﻧﻬﺎ ﺑﺰرﮔﺘﺮ از ﻋﺮض ﺳﺘﻮن ﺗﻜﻴﻪ ﮔﺎﻫﻲ اﺳﺖ‪ ،‬ﺟﺰﺋﻴﺎت ﻛﺎﻣﻞ اﺗﺼﺎل ﺗﻴﺮ ﺑﻪ ﺳﺘﻮن‬ ‫ﺑﺎ رﺳﻢ ﻧﺤﻮه ﻋﺒﻮر آرﻣﺎﺗﻮرﻫﺎي ﺗﻴﺮ از ﺳﺘﻮن ﻧﺸﺎن داده ﺷﻮﻧﺪ‪.‬‬ ‫‪ .13‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﺑﺮاي ﻗﺎﺑﻬﺎي ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي ﻣﺘﻮﺳﻂ و زﻳﺎد‪ ،‬ﻃﺒﻖ ﺑﻨﺪﻫﺎي ‪ 2-1-1-3-20-9‬و ‪2-1-1-4-20-9‬‬ ‫ﺑﺮون ﻣﺤﻮري ﻫﺮ ﻋﻀﻮ ﺧﻤﺸﻲ ﻧﺴﺒﺖ ﺑﻪ ﺳﺘﻮﻧﻲ ﻛﻪ ﺑﺎ آن ﻗﺎب ﺗﺸﻜﻴﻞ ﻣﻲ دﻫﺪ‪) ،‬ﻓﺎﺻﻠﻪ ﻣﺤﻮرﻫﺎي ﻫﻨﺪﺳﻲ دو‬ ‫ﻋﻀﻮ( ﻧﺒﺎﻳﺪ ﺑﻴﺸﺘﺮ از ﻳﻚ ﭼﻬﺎرم ﻋﺮض ﻣﻘﻄﻊ ﺳﺘﻮن ﺑﺎﺷﺪ‪.‬‬ ‫‪ .14‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ اﻳﻨﻜﻪ ﺑﺎﻳﺪ آرﻣﺎﺗﻮر ﺗﻴﺮﻫﺎ ﺑﺎ ﻗﻼب ◦‪ 90‬در ﺳﺘﻮﻧﻬﺎي ﻛﻨﺎري ﺳﺎزه ﻣﻬﺎر ﺷﻮﻧﺪ و ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ اﻳﻨﻜﻪ ﻃﻮل‬ ‫ﻗﻼب اﺳﺘﺎﻧﺪارد ◦‪ 90‬ﺣﺪود ‪ 15φ‬اﺳﺖ‪ ،‬ﺣﺪاﻗﻞ اﻧﺪازه ﻣﺠﺎز ﺳﺘﻮﻧﻬﺎ ‪ 35x35‬ﺳﺎﻧﺘﻴﻤﺘﺮ ﺧﻮاﻫﺪ ﺑﻮد ﻛﻪ در اﻳﻦ‬ ‫ﺣﺎﻟﺖ ﺣﺪاﻛﺜﺮ ﻗﻄﺮ ﻣﺠﺎز ﺑﺮاي آرﻣﺎﺗﻮر ﻃﻮﻟﻲ ﺗﻴﺮ ﺑﺮاﺑﺮ ‪ 18‬ﻣﻴﻠﻴﻤﺘﺮ اﺳﺖ‪ .‬ﺑﻪ ﻋﻨﻮان ﻳﻚ راﺑﻄﻪ ﺗﻘﺮﻳﺒﻲ‪ ،‬ﺣﺪاﻗﻞ ﺑﻌﺪ‬ ‫ﻻزم ﺑﺮاي ﺳﺘﻮن ﺑﺮ ﺣﺴﺐ ﻗﻄﺮ ﻣﻴﻠﮕﺮد ﺗﻴﺮ‪ ،‬ﺑﺮاﺑﺮ ‪ 15φ + 70‬ﻣﻴﻠﻴﻤﺘﺮ ﺧﻮاﻫﺪ ﺑﻮد‪.‬‬ ‫‪ .15‬در ﺻﻮرت اﺳﺘﻔﺎده از آرﻣﺎﺗﻮر ﺑﺮﺷﻲ ﻣﺎرﭘﻴﭻ‪ ،‬ﻃﺒﻖ ﺑﻨﺪ ‪ 3-4-9-11-9‬در ﻫﺮ ﮔﺎم ﻣﺎرﭘﻴﭻ ﻓﺎﺻﻠﻪ آزاد ﺑﻴﻦ ﻣﻴﻠﮕﺮدﻫﺎ‬ ‫ﻧﺒﺎﻳﺪ از ‪ 75‬ﻣﻴﻠﻴﻤﺘﺮ ﺑﻴﺸﺘﺮ ﺑﺎﺷﺪ‪.‬‬ ‫‪ .16‬در ﺻﻮرت اﺳﺘﻔﺎده از ﻗﺎب ﺧﻤﺸﻲ ﺑﺘﻨﻲ ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي زﻳﺎد‪ ،‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﻛﻨﺘﺮل آرﻣﺎﺗﻮر ﻋﺮﺿﻲ ﺳﺘﻮﻧﻬﺎ‬ ‫در ﻧﻮاﺣﻲ ﺑﺤﺮاﻧﻲ )ﻣﻮﺿﻮع ﺑﻨﺪ ‪ (2-3-2-4-20-9‬ﺗﻮﺳﻂ ﻧﺮم اﻓﺰار اﻧﺠﺎم ﻧﻤﻲ ﺷﻮد و اﻳﻦ ﻣﺤﺎﺳﺒﺎت ﺑﺎﻳﺪ ﺑﻪ‬ ‫ﺻﻮرت دﺳﺘﻲ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت اﻧﺠﺎم و آرﻣﺎﺗﻮر ﻻزم در ﻧﻘﺸﻪ ﻫﺎ درج ﮔﺮدد‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪17 :‬‬

‫‪ .17‬در ﺻﻮرت اﺳﺘﻔﺎده از دﻳﻮار ﺑﺮﺷﻲ‪ ،‬ﺑﺮاي اﻧﺘﻘﺎل ﺑﺎر از دﻳﺎﻓﺮاﮔﻢ ﺳﻘﻒ ﺑﻪ دﻳﻮار ﺑﺮﺷﻲ ﺑﺎﻳﺪ آرﻣﺎﺗﻮر دوﺧﺖ ﻣﻮرد‬ ‫ﻧﻴﺎز ﺑﺎ ﻋﻤﻠﻜﺮد ﺑﺮش اﺻﻄﻜﺎﻛﻲ ﻃﺒﻖ ﺑﺨﺶ ‪ 13-12-9‬ﺑﺮاي ﻧﻴﺮوﻫﺎي اﻧﺘﻘﺎﻟﻲ دﻳﺎﻓﺮاﮔﻢ ﻛﻪ از ﺑﺨﺶ ‪7-2-7-6‬‬ ‫ﻣﺤﺎﺳﺒﻪ ﻣﻲ ﺷﻮد ﻃﺮاﺣﻲ ﮔﺮدد‪ .‬اﻳﻦ ﻧﻜﺘﻪ ﺑﺎﻳﺪ در ﻣﻮرد دﻳﻮارﻫﺎﻳﻲ ﻛﻪ ﺑﻪ ﻋﻠﺖ ﻗﺮار ﮔﺮﻓﺘﻦ در ﻛﻨﺎر ﺑﺎزﺷﻮﻫﺎي‬ ‫ﺳﻘﻒ‪ ،‬اﺗﺼﺎل ﻛﺎﻣﻞ ﺑﻪ دﻳﺎﻓﺮاﮔﻢ ﻧﺪارﻧﺪ ﺑﻪ ﻃﻮر وﻳﮋه ﺑﺮرﺳﻲ ﺷﻮد‪ .‬ﺗﻮﺻﻴﻪ ﻣﻲ ﺷﻮد اﺻﻮﻻ از ﻛﺎرﺑﺮد دﻳﻮارﻫﺎي ﺑﺮﺷﻲ‬ ‫در ﻛﻨﺎر ﺑﺎزﺷﻮﻫﺎي ﺳﻘﻒ اﺟﺘﻨﺎب ﮔﺮدد‪.‬‬ ‫‪ .18‬در ﻣﻮرد داﻟﻬﺎي ﺑﺘﻨﻲ )ﺳﻘﻒ و رﻣﭗ( ﻛﻨﺘﺮل ﺣﺪاﻗﻞ ﺿﺨﺎﻣﺘﻬﺎ ﻃﺒﻖ ﺿﻮاﺑﻂ ﻓﺼﻞ ‪ 14‬ﻣﺒﺤﺚ ﻧﻬﻢ ﻣﻘﺮرات ﻣﻠﻲ‬ ‫ﺳﺎﺧﺘﻤﺎن در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت اﻧﺠﺎم ﮔﻴﺮد‪ .‬در ﻏﻴﺮ اﻳﻦ ﺻﻮرت ﺑﺎﻳﺪ ﻛﻨﺘﺮل ﺗﻐﻴﻴﺮ ﺷﻜﻞ ﺑﺮاي ﺿﺨﺎﻣﺖ ﻣﻮرد ﻧﻈﺮ‪،‬‬ ‫ﻃﺒﻖ ﺿﻮاﺑﻂ اﻳﻦ ﻓﺼﻞ ﺑﺎ اﻧﺠﺎم ﻣﺤﺎﺳﺒﺎت ﺗﻐﻴﻴﺮ ﺷﻜﻞ در ﺣﺎﻟﺖ ﺑﻬﺮه ﺑﺮداري‪ ،‬اﻧﺠﺎم ﺷﻮد‪.‬‬ ‫‪ .19‬ﻃﺒﻖ ﺑﻨﺪ ‪ 2-7-9-9‬در ﺳﺎزه ﻫﺎي ﺑﺘﻨﻲ در ﺻﻮرﺗﻲ ﻛﻪ ﻃﻮل ﻳﺎ ﻋﺮض ﺳﺎﺧﺘﻤﺎن از ﻣﻘﺎدﻳﺮ ﺗﻌﻴﻴﻦ ﺷﺪه )‪ 35‬ﻣﺘﺮ‬ ‫ﺑﺮاي ﺷﺮاﻳﻂ آب و ﻫﻮاﻳﻲ ﺗﻬﺮان( ﺗﺠﺎوز ﻛﻨﺪ‪ ،‬اﺟﺮاي درز اﻧﺒﺴﺎط ﺑﻪ ﻣﻘﺪار ﺣﺪاﻗﻞ ‪ αLΔT‬اﻟﺰاﻣﻲ اﺳﺖ‪ .‬درز‬ ‫اﻧﺒﺴﺎط ﺑﺎﻳﺪ در ﺷﺎﻟﻮده ﻧﻴﺰ اداﻣﻪ ﻳﺎﺑﺪ‪ .‬در ﺿﻤﻦ ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺷﺮاﻳﻂ ﺳﺎزه ﺑﺎﻳﺪ ﻣﻘﺪار درز اﻧﺒﺴﺎط ﺑﺎ ﺣﺪاﻗﻞ ﻋﺮض‬ ‫درز اﻧﻘﻄﺎع ﻧﻴﺰ ﻃﺒﻖ ﺑﻨﺪ ‪ 4-3-1-7-6‬ﻛﻨﺘﺮل ﮔﺮدد‪.‬‬ ‫‪ .20‬در ﻣﻮرد آرﻣﺎﺗﻮر ﻋﺮﺿﻲ ﺳﺘﻮﻧﻬﺎ در ﻗﺎﺑﻬﺎي ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي ﻣﺘﻮﺳﻂ و زﻳﺎد‪ ،‬ﺣﺪاﻗﻞ ﻃﻮل ﺑﺮاي ﻧﺎﺣﻴﻪ آرﻣﺎﺗﻮرﮔﺬاري‬ ‫ﻋﺮﺿﻲ وﻳﮋه ﺑﺮاﺑﺮ ﺣﺪاﻛﺜﺮ ﻣﻘﺎدﻳﺮ"ﻳﻚ ﺷﺸﻢ ارﺗﻔﺎع آزاد ﺳﺘﻮن‪ ،‬ﺿﻠﻊ ﺑﺰرﮔﺘﺮ ﻣﻘﻄﻊ ﻣﺴﺘﻄﻴﻞ ﻳﺎ ﻗﻄﺮ‬ ‫داﻳﺮه و ‪ 450‬ﻣﻴﻠﻴﻤﺘﺮ" ﻛﻨﺘﺮل ﺷﻮد‪ .‬ﻫﻤﭽﻨﻴﻦ ﺣﺪاﻛﺜﺮ ﻓﺎﺻﻠﻪ ﻣﺠﺎز آرﻣﺎﺗﻮرﻫﺎي ﻋﺮﺿﻲ در اﻳﻦ ﻧﺎﺣﻴﻪ ﺑﺮاﺑﺮ‬ ‫ﺣﺪاﻗﻞ ﻣﻘﺎدﻳﺮ"‪ 8‬ﺑﺮاﺑﺮ ﻗﻄﺮ ﻛﻮﭼﻜﺘﺮﻳﻦ ﻣﻴﻠﮕﺮد ﻃﻮﻟﻲ ﺳﺘﻮن‪ 24 ،‬ﺑﺮاﺑﺮ ﻗﻄﺮ ﺧﺎﻣﻮت‪ ،‬ﻧﺼﻒ ﻛﻮﭼﻜﺘﺮﻳﻦ‬ ‫ﺿﻠﻊ ﻣﻘﻄﻊ ﺳﺘﻮن و ‪ 150‬ﻣﻴﻠﻴﻤﺘﺮ" در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد و ﻓﺎﺻﻠﻪ اوﻟﻴﻦ آرﻣﺎﺗﻮر ﻋﺮﺿﻲ از ﺑﺮ اﺗﺼﺎل ﺳﺘﻮن ﺑﻪ ﺗﻴﺮ‬ ‫ﻧﺒﺎﻳﺪ ﺑﻴﺶ از ﻧﺼﻒ ﻣﻘﺎدﻳﺮ ﻓﻮق ﺑﺎﺷﺪ‪ .‬در ﻧﺎﺣﻴﻪ ﻣﻴﺎﻧﻲ ﺳﺘﻮن‪ ،‬ﺣﺪاﻛﺜﺮ ﻓﺎﺻﻠﻪ ﻣﺠﺎز آرﻣﺎﺗﻮرﻫﺎي ﻋﺮﺿﻲ ﺑﺮاﺑﺮ‬ ‫ﺣﺪاﻗﻞ ﻣﻘﺎدﻳﺮ "ﻧﺼﻒ ارﺗﻔﺎع ﻣﻮﺛﺮ ﻣﻘﻄﻊ )‪ (d/2‬و ‪ 250‬ﻣﻴﻠﻴﻤﺘﺮ" در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪.‬‬ ‫‪ .21‬در ﻣﻮرد ﺳﺘﻮﻧﻬﺎﻳﻲ ﻛﻪ ﻫﻢ در ﺗﺮاز ﻃﺒﻘﻪ و ﻫﻢ در ﺗﺮاز ﻣﻴﺎن ﻃﺒﻘﻪ ﺑﻪ آﻧﻬﺎ ﺗﻴﺮ ﻣﺘﺼﻞ ﻣﻲ ﺷﻮد )ﻣﺎﻧﻨﺪ ﺳﺘﻮﻧﻬﺎي‬ ‫ﭘﺎﮔﺮد ﭘﻠﻪ ﻫﺎ و ﺳﺘﻮﻧﻬﺎي واﻗﻊ در ﻣﺮز اﺧﺘﻼف ﺗﺮاز ﺳﺎﺧﺘﻤﺎﻧﻬﺎي دوﺑﻠﻜﺲ( ﺑﺮاي ﻛﻨﺘﺮل ﺑﻨﺪ ‪ ،20‬در اﻏﻠﺐ‬ ‫ﻣﻮارد اﺑﻌﺎد ﺳﺘﻮن ﺑﻪ ﻧﺤﻮي اﺳﺖ ﻛﻪ ﺑﺎﻳﺪ ﺧﺎﻣﻮت ﮔﺬاري وﻳﮋه در ﻛﻞ ارﺗﻔﺎع ﺳﺘﻮن ﺑﻪ ﺻﻮرت ﭘﻴﻮﺳﺘﻪ اﻧﺠﺎم ﮔﻴﺮد‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪18 :‬‬

‫‪ -6‬ﻧﻜﺎت ﺣﺎﺋﺰ اﻫﻤﻴﺖ در ﺟﺰﺋﻴﺎت ﺳﺎزه ﻫﺎي ﻓﻠﺰي‬

‫‪ .1‬در ﺻﻮرت اﺳﺘﻔﺎده از ﺳﻘﻒ ﻣﺮﻛﺐ‪ ،‬ﻃﺮاﺣﻲ ﺗﻴﺮﭼﻪ ﻫﺎي ﻓﻮﻻدي و ﻛﻨﺘﺮل ﺗﻐﻴﻴﺮ ﺷﻜﻞ آﻧﻬﺎ در ﻓﺎﻳﻞ ﺳﺎزه ﻳﺎ در‬ ‫دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت اﻧﺠﺎم ﺷﻮد‪ .‬ﻃﺮاﺣﻲ ﻛﺎﻣﻞ ﺑﺮش ﮔﻴﺮﻫﺎي ﻻزم در ﺗﻴﺮﻫﺎي ﻣﺮﻛﺐ ﻧﻴﺰ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ذﻛﺮ‬ ‫ﮔﺮدد‪ .‬در ﺗﻮﺿﻴﺤﺎت ﻧﻘﺸﻪ ﻟﺰوم ﻳﺎ ﻋﺪم ﻟﺰوم ﺷﻤﻊ ﺑﻨﺪي زﻳﺮ ﺗﻴﺮﭼﻪ ﻫﺎ‪ ،‬ﺑﺎ ﺗﻮﺟﻪ ﺑﺎ ﻓﺮﺿﻴﺎت ﻃﺮاﺣﻲ‪ ،‬ﺑﻪ ﻃﻮر‬ ‫دﻗﻴﻖ ﻣﺸﺨﺺ ﺷﻮد‪.‬‬ ‫‪ .2‬در ﻣﻮرد اﻋﻀﺎي ﻓﺸﺎري ﺑﺎ ﻣﻘﻄﻊ دوﺑﻞ ﺑﻪ وﻳﮋه ﺑﺎدﺑﻨﺪﻫﺎ‪ ،‬ﺑﺎﻳﺪ ﻃﺒﻖ ﺑﻨﺪ ‪-4-5-1-10‬ب ﻣﺒﺤﺚ دﻫﻢ‪ ،‬ﻗﻄﻌﺎت‬ ‫ﻟﻘﻤﻪ ﺑﻪ ﻓﻮاﺻﻞ ﻣﻨﺎﺳﺐ در ﻃﻮل اﻋﻀﺎء ﺑﻪ ﻧﺤﻮي ﺑﻪ ﻛﺎر روﻧﺪ ﻛﻪ ﺿﺮﻳﺐ ﻻﻏﺮي ﻧﻴﻤﺮخ ﺑﻴﻦ دو ﻗﻄﻌﻪ ﻟﻘﻤﻪ از ‪3/4‬‬ ‫ﺿﺮﻳﺐ ﻻﻏﺮي ﺗﻌﻴﻴﻦ ﻛﻨﻨﺪه ﻛﻞ ﻋﻀﻮ ﻣﺮﻛﺐ ﺗﺠﺎوز ﻧﻜﻨﺪ‪.‬‬ ‫‪ .3‬در ﻣﻮرد ورﻗﻬﺎي ﺗﻘﻮﻳﺘﻲ ﺑﺎل ﺗﻴﺮﻫﺎ‪ ،‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﻃﺒﻖ ﺑﻨﺪ ‪-6-2-1-10‬پ ﺑﺎﻳﺪ ﺳﻄﺢ ﻣﻘﻄﻊ ورق ﺗﻘﻮﻳﺘﻲ ﺑﺎل‬ ‫ﺗﻴﺮ از ‪ %70‬ﻣﺠﻤﻮع ﺳﻄﺢ ﻣﻘﻄﻊ ﺑﺎل ﺗﻴﺮ و ورق ﺗﻘﻮﻳﺘﻲ ﻛﻤﺘﺮ ﺑﺎﺷﺪ‪) .‬ﺑﻪ ﻋﺒﺎرت دﻳﮕﺮ ﺳﻄﺢ ﻣﻘﻄﻊ ورق ﺗﻘﻮﻳﺘﻲ‬ ‫از ﺣﺪود دو ﺑﺮاﺑﺮ ﺳﻄﺢ ﻣﻘﻄﻊ ﺑﺎل ﻛﻤﺘﺮ ﺑﺎﺷﺪ( ﻫﻤﭽﻨﻴﻦ ﻃﻮل ورﻗﻬﺎي ﺗﻘﻮﻳﺘﻲ ﺗﻴﺮﻫﺎ و ﻧﺤﻮه ﻗﻄﻊ آﻧﻬﺎ‪ ،‬ﻃﺒﻖ ﺑﻨﺪ‬ ‫‪-6-2-1-10‬ث ﻣﺤﺎﺳﺒﻪ و ﺟﺰﺋﻴﺎت ﻻزم ﺷﺎﻣﻞ اﺑﻌﺎد ورﻗﻬﺎ و ﻧﺤﻮه ﺟﻮﺷﻜﺎري در ﻧﻘﺸﻪ ﻫﺎ ذﻛﺮ ﮔﺮدد‪.‬‬ ‫‪ .4‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ در اﺗﺼﺎﻻت ﮔﻴﺮدار ﺗﻴﺮ ﺑﻪ ﺳﺘﻮن‪ ،‬ﻋﺮض ﺑﺎل ﺗﻴﺮ ﻣﺘﻨﺎﺳﺐ ﺑﺎ ﻋﺮض ﺑﺎل ﺳﺘﻮن ﺑﺎﺷﺪ ﺑﻪ ﻧﺤﻮي ﻛﻪ‬ ‫اﻣﻜﺎن اﻧﺘﻘﺎل ﻛﺎﻣﻞ ﻧﻴﺮوﻫﺎ از ﻃﺮﻳﻖ ورﻗﻬﺎي اﺗﺼﺎل ﮔﻴﺮدار ﺑﻪ ﺳﺘﻮن اﻣﻜﺎن ﭘﺬﻳﺮ ﺑﺎﺷﺪ‪.‬‬ ‫‪ .5‬ﺑﺮاي ﻗﺎﺑﻬﺎي ﺧﻤﺸﻲ ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي ﻣﺘﻮﺳﻂ‪ ،‬ﺑﺎﻳﺪ ﺿﻮاﺑﻂ ﺑﺨﺶ ‪ 8-3-10‬درﺑﺎره اﺗﺼﺎﻻت ﺗﻴﺮﻫﺎ و ﺳﺘﻮﻧﻬﺎ‪،‬‬ ‫ورﻗﻬﺎي ﭘﻴﻮﺳﺘﮕﻲ و ﻣﻘﺎوﻣﺖ ﺑﺮﺷﻲ ﺗﻴﺮﻫﺎي ﻗﺎب ﺧﻤﺸﻲ رﻋﺎﻳﺖ ﺷﻮد و ﻣﺤﺎﺳﺒﺎت ﻣﺮﺑﻮﻃﻪ در دﻓﺘﺮﭼﻪ‬ ‫ﻣﺤﺎﺳﺒﺎت و ﻓﺎﻳﻞ ﺳﺎزه اﻧﺠﺎم ﺷﻮد‪.‬‬ ‫‪ .6‬ﺑﺮاي ﻗﺎﺑﻬﺎي ﺧﻤﺸﻲ وﻳﮋه‪ ،‬رﻋﺎﻳﺖ ﻛﻠﻴﻪ ﺑﻨﺪﻫﺎي ﻣﺮﺑﻮﻃﻪ )‪ 1-9-3-10‬اﻟﻲ ‪ (6-9-3-10‬اﻟﺰاﻣﻲ اﺳﺖ‪ .‬ﻣﺤﺎﺳﺒﺎت‬ ‫و ﻛﻨﺘﺮﻟﻬﺎي ﻣﺮﺑﻮط ﺑﻪ اﻳﻦ ﺑﻨﺪﻫﺎ ﺑﺎﻳﺪ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت و ﻓﺎﻳﻞ ﺳﺎزه اﻧﺠﺎم ﺷﻮد‪ .‬در اﻳﻦ ﻣﻮرد ﺑﻪ وﻳﮋه ﺑﻪ ﻟﺰوم‬ ‫ﻣﻬﺎر ﺟﺎﻧﺒﻲ ﻫﺮ دو ﺑﺎل ﺗﻴﺮﻫﺎ ﻃﺒﻖ ﺑﻨﺪ ‪-4-9-3-10‬ت ﺗﻮﺟﻪ ﺷﻮد‪.‬‬ ‫‪ .7‬در ﻣﻬﺎرﺑﻨﺪي ﻫﺎي ﻫﻢ ﻣﺤﻮر رﻋﺎﻳﺖ ﺿﻮاﺑﻂ ﺑﺨﺶ ‪ 10-3-10‬اﻟﺰاﻣﻲ اﺳﺖ و ﻣﺤﺎﺳﺒﺎت ﻣﺮﺑﻮﻃﻪ ﺑﺎﻳﺪ در دﻓﺘﺮﭼﻪ‬ ‫ﻣﺤﺎﺳﺒﺎت و ﻓﺎﻳﻞ ﺳﺎزه در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪ .‬از ﺟﻤﻠﻪ ﻧﻜﺎت ﻣﻬﻢ در اﻳﻦ ﺑﺨﺶ‪ ،‬اﻋﻤﺎل ﺿﺮﻳﺐ ﻛﺎﻫﺶ ﺗﻨﺶ ﻣﺠﺎز ‪B‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪19 :‬‬

‫)ﺑﻨﺪ ‪-2-10-3-10‬ب( و ﻃﺮاﺣﻲ ﻣﻬﺎرﺑﻨﺪﻳﻬﺎي ‪ 7‬و ‪ 8‬ﺑﺮاي ‪ 1/5‬ﺑﺮاﺑﺮ ﻧﻴﺮوي زﻟﺰﻟﻪ اﺳﺖ‪ .‬ﻫﻤﭽﻨﻴﻦ ﺣﺪاﻛﺜﺮ‬ ‫‪6025‬‬ ‫ﺿﺮﻳﺐ ﻻﻏﺮي‪ ،‬ﻃﺒﻖ ﺑﻨﺪ ‪-2-10-3-10‬اﻟﻒ ﺑﻪ‬ ‫‪Fy‬‬

‫ﻣﺤﺪود ﺷﺪه اﺳﺖ‪.‬‬

‫‪ .8‬ﺑﺮاي اﺗﺼﺎﻻت ﺗﻴﺮﻫﺎ‪ ،‬ﺳﺘﻮﻧﻬﺎ‪ ،‬ﺑﺎدﺑﻨﺪﻫﺎ و وﺻﻠﻪ ﻫﺎي آﻧﻬﺎ ﺗﻌﺪاد ﻛﺎﻓﻲ ﺟﺰﺋﻴﺎت در وﺿﻌﻴﺖ ﻫﺎي ﻣﺨﺘﻠﻒ ﻣﻮﺟﻮد در‬ ‫ﺳﺎزه رﺳﻢ ﺷﻮد‪ .‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﻣﻄﺎﺑﻖ ﺷﻜﻞ زﻳﺮ ورﻗﻬﺎي ﭘﻴﻮﺳﺘﮕﻲ در داﺧﻞ ﺳﺘﻮﻧﻬﺎ ﺑﻪ ﻧﺤﻮي اراﺋﻪ ﺷﻮﻧﺪ ﻛﻪ ﺑﺎ‬ ‫اﺗﺼﺎل ﺗﻴﺮ ﻣﺘﻌﺎﻣﺪ ﺑﺮﺧﻮرد ﻧﺪاﺷﺘﻪ ﺑﺎﺷﻨﺪ‪.‬‬

‫‪ .9‬در ﺻﻮرت اﺳﺘﻔﺎده از اﺗﺼﺎﻻت ﭘﻴﭽﻲ‪ ،‬ﺗﻮﺻﻴﻪ ﻣﻲ ﺷﻮد ﻫﻤﻮاره از اﺗﺼﺎﻻت اﺻﻄﻜﺎﻛﻲ اﺳﺘﻔﺎده ﺷﻮد‪ .‬ﺑﻪ ﻫﺮﺣﺎل‬ ‫ﺑﺮاي ﺷﺮاﻳﻂ ذﻛﺮ ﺷﺪه در ﺑﻨﺪ ‪-1-7-1-10‬ش اﺳﺘﻔﺎده از اﺗﺼﺎﻻت اﺻﻄﻜﺎﻛﻲ )ﻳﺎ ﺟﻮﺷﻲ( اﻟﺰاﻣﻲ اﺳﺖ و ﻛﺎرﺑﺮد‬ ‫اﺗﺼﺎﻻت ﭘﻴﭽﻲ اﺗﻜﺎﻳﻲ ﻣﺠﺎز ﻧﻴﺴﺖ‪.‬‬ ‫‪ .10‬در ﺻﻮرت اﺳﺘﻔﺎده از ﺳﺘﻮن ﻫﺎي ﻓﻠﺰي در ﺗﺮﻛﻴﺐ ﺑﺎ دﻳﻮارﻫﺎي ﺑﺮﺷﻲ ﺑﻪ ﻣﻮارد ذﻳﻞ ﺗﻮﺟﻪ ﮔﺮدد‪:‬‬ ‫• ﺑﺮاي ﻋﻤﻠﻜﺮد ﻳﻜﭙﺎرﭼﻪ ﺳﺘﻮن ﻓﻠﺰي و دﻳﻮار ﺑﺘﻨﻲ‪ ،‬ﺑﺎﻳﺪ اﻧﺘﻘﺎل ﻧﻴﺮو ﺑﻴﻦ دو ﻣﺠﻤﻮﻋﻪ ﺗﻮﺳﻂ ﺑﺮش ﮔﻴﺮﻫﺎﻳﻲ از‬ ‫ﭘﺮوﻓﻴﻞ ﻧﺎوداﻧﻲ در ارﺗﻔﺎع ﺳﺘﻮن اﻧﺠﺎم ﮔﻴﺮد‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪20 :‬‬

‫• در ﺻﻮرﺗﻲ ﻛﻪ ﺳﺘﻮن ﻛﺎﻣﻼ در داﺧﻞ دﻳﻮار ﻣﺤﺎط ﺷﻮد آرﻣﺎﺗﻮر ﻫﺎي اﻓﻘﻲ دﻳﻮار ﺑﺎﻳﺪ ﺑﻪ ﺻﻮرت ﭘﻴﻮﺳﺘﻪ از ﻛﻨﺎر‬ ‫ﺳﺘﻮن ﻋﺒﻮر ﻛﻨﻨﺪ‪.‬‬ ‫• در ﺻﻮرﺗﻲ ﻛﻪ ﺳﺘﻮن دﻳﻮار را ﺑﻪ دو ﺑﺨﺶ ﺗﻘﺴﻴﻢ ﻛﻨﺪ و اﻣﻜﺎن اﺟﺮاي ﭘﻴﻮﺳﺘﻪ آرﻣﺎﺗﻮر اﻓﻘﻲ دﻳﻮار در ﻣﺤﻞ ﺳﺘﻮن‬ ‫وﺟﻮد ﻧﺪاﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ﺑﺎﻳﺪ آرﻣﺎﺗﻮرﻫﺎي اﻓﻘﻲ در ﺑﺮ ﺳﺘﻮن ﺑﻪ ﻗﻼب اﺳﺘﺎﻧﺪارد ﺧﺘﻢ ﺷﻮﻧﺪ‪.‬‬ ‫• اﮔﺮ ﻣﻘﻄﻊ ﺳﺘﻮن ﺑﺴﺘﻪ ﺑﺎﺷﺪ )ﻧﻈﻴﺮ ﻗﻮﻃﻲ ﻳﺎ ﻟﻮﻟﻪ( در ﻣﺤﻞ ﺗﻤﺎس ﺑﺎ دﻳﻮار ﺑﺮاي ﺟﻠﻮﮔﺮي از ﻟﻬﻴﺪﮔﻲ ﺳﺘﻮن‪،‬‬ ‫ﺗﻮﺻﻴﻪ ﻣﻲ ﺷﻮد ﻣﻘﻄﻊ آن ﺑﺎ ﺑﺘﻦ )ﻋﻴﺎر ‪ (150‬ﭘﺮ ﺷﻮد‪.‬‬ ‫‪ .11‬ﺗﻮﺻﻴﻪ ﻣﻴﺸﻮد در ﻗﺎﺑﻬﺎي ﺧﻤﺸﻲ ﻓﻮﻻدي ﻣﺘﻮﺳﻂ و وﻳﮋه‪ ،‬ﺣﺘﻲ اﻟﻤﻘﺪور از ﭘﺮوﻓﻴﻞ ﻫﺎي ‪ I‬ﺷﻜﻞ )‪ IPE‬ﻳﺎ ﺗﻴﺮ‬ ‫ورق( ﺑﺎ ورﻗﻬﺎي ﺗﻘﻮﻳﺘﻲ ﺑﺎل‪ ،‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻣﺸﻜﻼﺗﻲ ﻛﻪ در ﻛﻨﺘﺮل ﺿﻮاﺑﻂ ﻟﺮزه اي اﻳﺠﺎد ﻣﻴﻜﻨﻨﺪ اﺳﺘﻔﺎده ﻧﺸﻮد‪.‬‬ ‫ﻣﻌﻤﻮﻻ ﻛﺎرﺑﺮد ورق ﻫﺎي ﺗﻘﻮﻳﺘﻲ ﻣﺬﻛﻮر ﻇﺮﻓﻴﺖ ﺧﻤﺸﻲ ﭘﻼﺳﺘﻴﻚ ﻣﻘﻄﻊ را ﺗﺎ ﺣﺪي ﺑﺎل ﻣﻲ ﺑﺮد ﻛﻪ ﻣﻘﺎوﻣﺖ‬ ‫ﺑﺮﺷﻲ ﺟﺎن‪ ،‬ﺟﻮاﺑﮕﻮي ﻧﻴﺮوﻫﺎي ﺑﺮﺷﻲ ذﻛﺮ ﺷﺪه در ﺑﻨﺪ ‪ 4-8-3-10‬ﻳﺎ ‪-4-9-3-10‬اﻟﻒ ﻧﺨﻮاﻫﺪ ﺑﻮد‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪21 :‬‬

‫‪ -7‬ﻧﻜﺎت ﻣﻬﻢ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت‬

‫‪ .1‬در اﺑﺘﺪاي دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ﺑﺎﻳﺪ ﻣﺸﺨﺼﺎت ﻛﻠﻲ ﭘﺮوژه‪ ،‬ﺷﺎﻣﻞ ﻣﺤﻞ زﻣﻴﻦ‪ ،‬ﻛﺎرﺑﺮي‪ ،‬اﺑﻌﺎد‪ ،‬ﺗﻌﺪاد ﻃﺒﻘﺎت‪،‬‬ ‫ﺳﻴﺴﺘﻤﻬﺎي ﻣﻘﺎوم ﺑﺎرﺑﺮ ﺛﻘﻠﻲ و ﺟﺎﻧﺒﻲ‪ ،‬آﻳﻴﻦ ﻧﺎﻣﻪ ﻫﺎ و ﻧﺮم اﻓﺰارﻫﺎي ﻣﻮرد اﺳﺘﻔﺎده و ﻧﻜﺎت ﻣﻬﻢ ﮔﺰارش ﺧﺎك از‬ ‫ﺟﻤﻠﻪ ﻧﻮع ﺧﺎك از ﻧﻈﺮ ﻟﺮزه اي‪ ،‬ﺗﻨﺶ ﻣﺠﺎز و ﺿﺮﻳﺐ ﻋﻜﺲ اﻟﻌﻤﻞ ﺧﺎك ﺑﺮاي اﻧﻮاع ﺷﺎﻟﻮده ﻫﺎ ذﻛﺮﮔﺮدد‪.‬‬ ‫‪ .2‬دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ﺑﺎﻳﺪ ﺑﻪ ﻣ‪‬ﻬﺮ ﻣﻬﻨﺪس ﻃﺮاح و ﺷﺮﻛﺖ ﻣﺸﺎور ﻣﺮﺑﻮﻃﻪ ﻣﻤﻬﻮر ﮔﺮدد‪.‬‬ ‫‪ .3‬ﺑﺎرﮔﺬاري ﺛﻘﻠﻲ ﺑﺎﻳﺪ ﺑﻪ ﻃﻮر ﻛﺎﻣﻞ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ﺷﺮح داده ﺷﻮد‪ .‬در ﺑﺎرﮔﺬاري ﺛﻘﻠﻲ ﺑﺎﻳﺪ ﺟﺰﺋﻴﺎت ﻛﻠﻴﻪ‬ ‫ﺳﻘﻔﻬﺎ‪ ،‬دﻳﻮارﻫﺎي ﭘﻴﺮاﻣﻮﻧﻲ و ﺗﻴﻐﻪ ﺑﻨﺪي ﻫﺎ ﻃﺒﻖ ﻧﻘﺸﻪ ﻫﺎي ﻣﻌﻤﺎري ﻣﺸﺨﺺ ﺷﻮد و ﻣﺤﺎﺳﺒﻪ ﺑﺎر ﺑﺮ اﺳﺎس آن و‬ ‫ﺿﻮاﺑﻂ ﻣﺒﺤﺚ ﺷﺸﻢ اﻧﺠﺎم ﮔﻴﺮد‪ .‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ در ﺟﺰﺋﻴﺎت ﺑﺎرﮔﺬاري ﺳﻘﻒ ﻃﺒﻘﺎت‪ ،‬ﻣﺼﺎﻟﺢ ﭘﺮ ﻛﻨﻨﺪه ﺑﺮاي ﻋﺒﻮر‬ ‫ﻟﻮﻟﻪ ﻫﺎ ﺑﺎﻳﺪ از ﻧﻮع ﭘﻮﻛﻪ ﻣﻌﺪﻧﻲ ﺑﺎ ﺣﺪاﻗﻞ وزن ﻣﺨﺼﻮص ‪ 1000 kg/m3‬و ﺑﺎ ﺿﺨﺎﻣﺖ ﺣﺪاﻗﻞ ‪ 7‬ﺳﺎﻧﺘﻴﻤﺘﺮ و‬ ‫ﺿﺨﺎﻣﺖ ﻣﺼﺎﻟﺢ ﭘﺮﻛﻨﻨﺪه ﺑﺮاي ﺷﻴﺐ ﺑﻨﺪي ﺑﺎم‪ ،‬ﺣﺪاﻗﻞ ﺑﺮاﺑﺮ ‪ 15‬ﺳﺎﻧﺘﻴﻤﺘﺮ در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪ .‬ﺑﺎرﻫﺎي زﻧﺪه ﺑﺮاي‬ ‫ﻫﺮ ﻓﻀﺎ ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻛﺎرﺑﺮي آن از ﻣﺒﺤﺚ ﺷﺸﻢ ﺗﻌﻴﻴﻦ و در ﻣﺤﺎﺳﺒﺎت ﻣﻨﻈﻮر ﺷﻮﻧﺪ‪ .‬در ﻣﻮرد ﺑﺎﻟﻜﻦ ﺳﺎﺧﺘﻤﺎن ﻫﺎي‬ ‫ﻣﺴﻜﻮﻧﻲ‪ ،‬ﺣﺪاﻗﻞ ﺑﺎر زﻧﺪه ﮔﺴﺘﺮده ﺑﺮاﺑﺮ ‪ 300 kg/m2‬اﻋﻤﺎل ﮔﺮدد‪.‬‬ ‫‪ .4‬ﺑﺎرﮔﺬاري ﺟﺎﻧﺒﻲ ﺳﺎزه ﺑﺎﻳﺪ ﺑﻪ ﻃﻮر ﻛﺎﻣﻞ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ﺷﺮح داده ﺷﻮد‪ .‬در ﺑﺎرﮔﺬاري ﺟﺎﻧﺒﻲ‪ ،‬ﺟﺰﺋﻴﺎت‬ ‫ﻣﺤﺎﺳﺒﻪ زﻣﺎن ﺗﻨﺎوب ﻣﻮرد اﺳﺘﻔﺎده و ﺑﺎرﻫﺎي اﺳﺘﺎﺗﻴﻜﻲ ﻣﻌﺎدل )و دﻳﻨﺎﻣﻴﻜﻲ در ﺻﻮرت ﻟﺰوم( ﺑﻪ ﻃﻮر ﻛﺎﻣﻞ‬ ‫اراﺋﻪ ﺷﻮد‪ .‬درﺻﺪ ﻣﺸﺎرﻛﺖ ﺑﺎر زﻧﺪه و ﺑﺎر ﺑﺮف در ﻣﺤﺎﺳﺒﻪ ﻧﻴﺮوي ﺟﺎﻧﺒﻲ زﻟﺰﻟﻪ ﻃﺒﻖ ﺟﺪول ‪ 1-7-6‬ﻣﺒﺤﺚ ﺷﺸﻢ‬ ‫ﺗﻌﻴﻴﻦ ﺷﻮد‪.‬‬ ‫‪ .5‬در ﺻﻮرت ﻣﻨﻈﻢ ﺑﻮدن ﺳﺎزه‪ ،‬ﻛﻨﺘﺮل ﻛﻠﻴﻪ ﺑﻨﺪﻫﺎي ﺑﺨﺶ ‪ 8-1-7-6‬ﻣﺒﺤﺚ ﺷﺸﻢ ﺑﺎﻳﺪ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت‬ ‫ذﻛﺮ ﮔﺮدد‪ .‬در ﺻﻮرت ﻧﺎﻣﻨﻈﻢ ﺑﻮدن ﺳﺎزه در ارﺗﻔﺎع ﻳﺎ ﭘﻼن و ﻋﺪم ﻛﻔﺎﻳﺖ ﺗﺤﻠﻴﻞ اﺳﺘﺎﺗﻴﻜﻲ )ﻃﺒﻖ ﺑﺨﺶ ‪-2-7-6‬‬ ‫‪ (3‬ﺟﺰﺋﻴﺎت ﺗﺤﻠﻴﻞ ﻃﻴﻔﻲ و در ﺻﻮرت ﻟﺰوم ﻧﺤﻮه ﺗﺮﻛﻴﺐ اﺛﺮات زﻟﺰﻟﻪ در دو ﺟﻬﺖ ﻣﺘﻌﺎﻣﺪ )ﺑﻨﺪ ‪(3-1-2-7-6‬‬ ‫اراﺋﻪ ﮔﺮدد‪.‬‬ ‫‪ .6‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ در ﻛﻨﺘﺮل ﻧﺎﻣﻨﻈﻤﻲ ﭘﻴﭽﺸﻲ )ﺑﻨﺪ ‪-1-1-8-1-7-6‬ث( ﺑﺎﻳﺪ ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﻧﺴﺒﻲ در ﻫﺮ ﻃﺒﻘﻪ ﻣﻮرد‬ ‫ﺗﻮﺟﻪ ﻗﺮار ﮔﻴﺮد‪ ،‬وﻟﻲ در ﻣﺤﺎﺳﺒﻪ ﺿﺮﻳﺐ ‪) Aj‬ﺑﻨﺪ ‪ (3-10-5-2-7-6‬ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﻣﻮرد اﺳﺘﻔﺎده‪ ،‬ﺗﻐﻴﻴﺮ ﻣﻜﺎن‬ ‫ﻣﻄﻠﻖ ﻃﺒﻘﻪ اﺳﺖ‪ .‬ﺧﺮوﺟﻲ ﻧﺮم اﻓﺰار ‪ ETABS2000‬در ﺑﺨﺶ ‪ Summary Report‬ﻧﻴﺰ ﺑﺮ ﻣﺒﻨﺎي ﺗﻐﻴﻴﺮ ﻣﻜﺎن‬ ‫ﻣﻄﻠﻖ ﻃﺒﻘﻪ اﺳﺖ و ﺗﻨﻬﺎ در ﻣﺤﺎﺳﺒﻪ ‪ Aj‬ﻗﺎﺑﻞ اﺳﺘﻔﺎده اﺳﺖ‪ .‬ﺑﻨﺎﺑﺮاﻳﻦ ﻣﻤﻜﻦ اﺳﺖ در ﺑﺮﺧﻲ ﺳﺎزه ﻫﺎ ﻧﺎﻣﻨﻈﻤﻲ‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪22 :‬‬

‫ﭘﻴﭽﺸﻲ )ﺑﻨﺪ ‪-1-1-8-1-7-6‬ث و ﺑﺎ ﻛﻨﺘﺮل ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﻧﺴﺒﻲ در ﻫﺮ ﻃﺒﻘﻪ( وﺟﻮد داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ﻟﻴﻜﻦ ﻣﻘﺪار‬ ‫ﻣﺤﺎﺳﺒﻪ ﺷﺪه ﺑﺮاي ﺿﺮﻳﺐ ‪) Aj‬ﺑﺮ ﻣﺒﻨﺎي ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﻣﻄﻠﻖ ﻃﺒﻘﻪ( ﻛﻤﺘﺮ از واﺣﺪ ﺑﺎﺷﺪ‪ .‬در اﻳﻦ ﺷﺮاﻳﻂ ﺳﺎزه در‬ ‫ﭘﻼن ﻧﺎﻣﻨﻈﻢ ﻣﺤﺴﻮب ﺷﺪه و ﺑﺎﻳﺪ ﺿﻮاﺑﻂ ﻣﺮﺑﻮط ﺑﻪ ﻧﺎﻣﻨﻈﻤﻲ در ﭘﻼن‪ ،‬از ﺟﻤﻠﻪ ﺗﺮﻛﻴﺐ اﺛﺮ زﻟﺰﻟﻪ در دوﺟﻬﺖ )ﺑﻨﺪ‬ ‫‪ (3-1-2-7-6‬در ﺗﺤﻠﻴﻞ ﺳﺎزه ﻣﺪ ﻧﻈﺮ ﻗﺮار ﮔﻴﺮد‪ ،‬ﻟﻴﻜﻦ ﺿﺮﻳﺐ ‪ Aj‬ﺑﺮاﺑﺮ واﺣﺪ درﻧﻈﺮ ﮔﺮﻓﺘﻪ ﻣﻲ ﺷﻮد‪ .‬ﺑﻨﺎﺑﺮاﻳﻦ ﻻزم‬ ‫ﺑﻪ ﺗﻮﺟﻪ اﻛﻴﺪ اﺳﺖ ﻛﻪ در ﺗﻌﻴﻴﻦ وﺟﻮد ﻳﺎ ﻋﺪم وﺟﻮد ﻧﺎﻣﻨﻈﻤﻲ ﭘﻴﭽﺸﻲ‪ ،‬اﺳﺘﻨﺎد ﺑﻪ ﺧﺮوﺟﻲ ﻧﺮم اﻓﺰار ‪ ETABS‬در‬ ‫ﺑﺨﺶ ‪ Summary Report‬ﻗﺎﺑﻞ ﻗﺒﻮل ﻧﺒﻮده و اﻳﻦ ﻛﻨﺘﺮل ﺑﺎﻳﺪ ﺑﺮ ﻣﺒﻨﺎي ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﻧﺴﺒﻲ در ﻫﺮ ﻃﺒﻘﻪ اﻧﺠﺎم و‬ ‫رﻳﺰ ﻣﺤﺎﺳﺒﺎت در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت اﺿﺎﻓﻪ ﺷﻮد‪.‬‬ ‫‪ .7‬در ﺻﻮرت وﺟﻮد ﻓﺸﺎر ﺟﺎﻧﺒﻲ ﺧﺎك‪ ،‬ﺑﺎﻳﺪ ﻣﺤﺎﺳﺒﺎت ﻣﺮﺑﻮط ﺑﻪ ﻃﺮاﺣﻲ دﻳﻮارﻫﺎي ﭘﻴﺮاﻣﻮﻧﻲ ﺑﺮاي ﻓﺸﺎر ﻓﻌﺎل‬ ‫اﺳﺘﺎﺗﻴﻜﻲ و دﻳﻨﺎﻣﻴﻜﻲ ﺧﺎك و ﺳﺮﺑﺎر ﻧﺎﺷﻲ از ﺳﺎﺧﺘﻤﺎﻧﻬﺎي ﻣﺠﺎور در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت اراﺋﻪ ﮔﺮدد‪ .‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ‬ ‫ﻧﺮم اﻓﺰار ‪ ETABS‬ﻃﺮاﺣﻲ دﻳﻮار را ﺑﺮاي ﺧﻤﺶ ﺣﻮل ﻣﺤﻮر ﺿﻌﻴﻒ )ﺿﺨﺎﻣﺖ دﻳﻮار( اﻧﺠﺎم ﻧﻤﻲ دﻫﺪ‪.‬‬ ‫‪ .8‬در ﺻﻮرت اﺳﺘﻔﺎده از ﺳﻘﻒ ﺗﻴﺮﭼﻪ ﺑﻠﻮك ﻳﺎ ﺳﻘﻒ ﻣﺮﻛﺐ‪ ،‬ﺟﺰﺋﻴﺎت ﻃﺮاﺣﻲ ﺗﻴﺮﭼﻪ ﻫﺎي ﺑﺘﻨﻲ و ﻳﺎ ﻓﻠﺰي و ﺑﺮش‬ ‫ﮔﻴﺮﻫﺎي ﺳﻘﻒ ﻣﺮﻛﺐ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ذﻛﺮ ﺷﻮد‪ .‬اﮔﺮ ﻃﺮاﺣﻲ ﺗﻴﺮﭼﻪ ﻫﺎي ﺳﻘﻒ ﻣﺮﻛﺐ ﺗﻮﺳﻂ ﻧﺮم اﻓﺰار‬ ‫‪ ETABS‬اﻧﺠﺎم ﻣﻲ ﮔﻴﺮد‪ ،‬ﻓﺮﺿﻴﺎت ﻃﺮاﺣﻲ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ذﻛﺮ ﺷﻮد‪.‬‬ ‫‪ .9‬ﺑﺮاي ﺳﺎزه ﻫﺎي ﺑﺘﻨﻲ‪ ،‬در ﺻﻮرت وﺟﻮد دﻳﻮار ﺑﺮﺷﻲ‪ ،‬درﺑﺎره ﻧﺤﻮه ﻃﺮاﺣﻲ دﻳﻮار در ﻓﺎﻳﻞ ﻛﺎﻣﭙﻴﻮﺗﺮي ﺗﻮﺿﻴﺤﺎت‬ ‫ﻻزم درج ﺷﻮد‪.‬‬ ‫‪ .10‬در ﺻﻮرت اﺳﺘﻔﺎده از ﺷﻤﻊ در ﺷﺎﻟﻮده‪ ،‬ﻓﺮﺿﻴﺎت ﺗﺤﻠﻴﻞ و ﻃﺮاﺣﻲ و ﻛﻨﺘﺮل ﺷﻤﻊ ﺑﺮاي ﻧﻴﺮوﻫﺎي ﻓﺸﺎري و‬ ‫ﻛﺸﺸﻲ وارده در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ذﻛﺮ ﮔﺮدد‪.‬‬ ‫‪ .11‬در ﺻﻮرت اﺳﺘﻔﺎده از ﻗﺎب ﺧﻤﺸﻲ ﺑﺘﻨﻲ ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي زﻳﺎد‪ ،‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﻛﻨﺘﺮل آرﻣﺎﺗﻮر ﻋﺮﺿﻲ ﺳﺘﻮﻧﻬﺎ در‬ ‫ﻧﻮاﺣﻲ ﺑﺤﺮاﻧﻲ )ﻣﻮﺿﻮع ﺑﻨﺪ ‪ (2-3-2-4-20-9‬ﺗﻮﺳﻂ ﻧﺮم اﻓﺰار اﻧﺠﺎم ﻧﻤﻲ ﺷﻮد و اﻳﻦ ﻣﺤﺎﺳﺒﺎت ﺑﺎﻳﺪ ﺑﻪ‬ ‫ﺻﻮرت دﺳﺘﻲ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت اﻧﺠﺎم و آرﻣﺎﺗﻮر ﻻزم در ﻧﻘﺸﻪ ﻫﺎ درج ﮔﺮدد‪.‬‬ ‫‪ .12‬ﺑﺮاي ﺳﺎزه ﻫﺎي ﻓﻠﺰي‪ ،‬ﻃﺮاﺣﻲ اﺗﺼﺎﻻت ﺗﻴﺮﻫﺎي ﺳﺎده و ﮔﻴﺮدار‪ ،‬وﺻﻠﻪ ﺳﺘﻮﻧﻬﺎ‪ ،‬ورق ﻛﻒ ﺳﺘﻮن)ﺑﻪ وﻳﮋه‬ ‫ﺳﺘﻮﻧﻬﺎي ﮔﻴﺮدار واﻗﻊ در ﮔﻮﺷﻪ ﻫﺎ( و ﺑﺎدﺑﻨﺪﻫﺎ ﺑﺮاي ﺣﺪاﻗﻞ دو ﺣﺎﻟﺖ ﺑﺤﺮاﻧﻲ اراﺋﻪ ﺷﻮد‪.‬‬ ‫‪ .13‬در ﺳﺎزه ﻫﺎي ﻓﻠﺰي‪ ،‬ﻛﻨﺘﺮل ﻣﻘﺎدﻳﺮ ‪ b/t‬و ‪ h/tw‬ﺑﺮاي ﺗﻴﺮﻫﺎ و ﺳﺘﻮﻧﻬﺎ‪ ،‬ﻃﺒﻖ ﺑﺨﺶ ‪ 9-1-1-10‬و ‪ 3-10‬ﻣﺒﺤﺚ‬ ‫دﻫﻢ اﻧﺠﺎم ﮔﻴﺮد‪ .‬در ﺿﻤﻦ ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﺑﺮاي ﻓﺸﺮده ﺑﻮدن ﻣﻘﻄﻊ ﺗﻴﺮورﻗﻬﺎ‪ ،‬ﺑﺎﻳﺪ ﺟﻮش ﺑﺎل ﺑﻪ ﺟﺎن ﺳﺮاﺳﺮي‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫دا ﻧ ﻮ‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫ﺻﻔﺤﻪ‪23 :‬‬

‫ﺑﺎﺷﺪ‪ .‬در ﺻﻮرت ﻋﺪم ﻛﺎرﺑﺮد ﺟﻮش ﺳﺮاﺳﺮي‪ ،‬ﻣﻘﻄﻊ ﺗﻴﺮورق ﻓﺸﺮده ﻣﺤﺴﻮب ﻧﺸﺪه و ﻧﻤﻲ ﺗﻮان از ﺗﻨﺶ ﻣﺠﺎز‬ ‫ﺧﻤﺸﻲ ‪ 0.66Fy‬اﺳﺘﻔﺎده ﻛﺮد‪ .‬اﻳﻦ ﻧﻜﺘﻪ ﺑﺎﻳﺪ در ﺗﻨﺶ ﻣﺠﺎز ﻣﻮرد اﺳﺘﻔﺎده در ﻃﺮاﺣﻲ ﻛﺎﻣﭙﻴﻮﺗﺮي ﻧﻴﺰ ﺑﺎﻳﺪ ﻣﺪ ﻧﻈﺮ‬ ‫ﻗﺮار ﮔﻴﺮد‪.‬‬ ‫‪ .14‬ﺑﺮاي ﻗﺎﺑﻬﺎي ﺧﻤﺸﻲ ﻓﻮﻻدي ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي ﻣﺘﻮﺳﻂ‪ ،‬ﺑﺎﻳﺪ ﺿﻮاﺑﻂ ﺑﺨﺶ ‪ 8-3-10‬درﺑﺎره اﺗﺼﺎﻻت ﺗﻴﺮﻫﺎ و‬ ‫ﺳﺘﻮﻧﻬﺎ‪ ،‬ورﻗﻬﺎي ﭘﻴﻮﺳﺘﮕﻲ و ﻣﻘﺎوﻣﺖ ﺑﺮﺷﻲ ﺗﻴﺮﻫﺎي ﻗﺎب ﺧﻤﺸﻲ رﻋﺎﻳﺖ ﺷﻮد و ﻣﺤﺎﺳﺒﺎت ﻣﺮﺑﻮﻃﻪ در دﻓﺘﺮﭼﻪ‬ ‫ﻣﺤﺎﺳﺒﺎت اراﺋﻪ ﮔﺮدد‪.‬‬ ‫‪ .15‬ﺑﺮاي ﻗﺎﺑﻬﺎي ﺧﻤﺸﻲ ﻓﻮﻻدي وﻳﮋه‪ ،‬رﻋﺎﻳﺖ ﻛﻠﻴﻪ ﺑﻨﺪﻫﺎي ﻣﺮﺑﻮﻃﻪ )‪ 1-9-3-10‬اﻟﻲ ‪ (6-9-3-10‬اﻟﺰاﻣﻲ اﺳﺖ‪.‬‬ ‫ﻣﺤﺎﺳﺒﺎت و ﻛﻨﺘﺮﻟﻬﺎي ﻣﺮﺑﻮط ﺑﻪ اﻳﻦ ﺑﻨﺪﻫﺎ ﺑﺎﻳﺪ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ذﻛﺮ ﺷﻮد‪.‬‬ ‫‪ .16‬در ﺳﺎزه ﻫﺎي ﻓﻠﺰي‪ ،‬ﺑﺮاي ﺗﻴﺮﻫﺎ و ﺷﺎﻫﺘﻴﺮﻫﺎ ﻛﻨﺘﺮل اﻓﺘﺎدﮔﻲ و ارﺗﻌﺎش ﻃﺒﻖ ﺿﻮاﺑﻂ ﺑﺨﺶ ‪ 3-9-1-10‬اﻧﺠﺎم‬ ‫ﮔﻴﺮد‪ .‬ﻣﻮاردي ﻛﻪ در ﻓﺎﻳﻞ ﺳﺎزه ﻗﺎﺑﻞ ﻛﻨﺘﺮل ﻧﻴﺴﺖ‪ ،‬در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ﺑﻪ ﺻﻮرت دﺳﺘﻲ ﻛﻨﺘﺮل ﮔﺮدد‪.‬‬ ‫‪ .17‬ﺑﺮاي ﻛﻨﺘﺮل ﺗﻐﻴﻴﺮ ﺷﻜﻞ ﺟﺎﻧﺒﻲ ﺳﺎزه ﻧﺤﺖ اﺛﺮ زﻟﺰﻟﻪ‪ ،‬ﺑﺎﻳﺪ ﺟﺪول ﺧﺮوﺟﻲ ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﻧﺴﺒﻲ ﺣﺎﺻﻞ از ﺗﺤﻠﻴﻞ‬ ‫در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﻪ درج ﺷﻮد و ﻣﻘﺎدﻳﺮ ﻣﺠﺎز ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﻧﺴﺒﻲ ﻧﻴﺰ ﺑﺮ ﻣﺒﻨﺎي ﻣﺒﺤﺚ ﺷﺸﻢ ﻣﻘﺮرات ﻣﻠﻲ‬ ‫ﺳﺎﺧﺘﻤﺎن ﻣﺤﺎﺳﺒﻪ‪ ،‬ذﻛﺮ و ﺑﺎ ﻣﻘﺎدﻳﺮ ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﻣﻮﺟﻮد ﻣﻘﺎﻳﺴﻪ ﮔﺮدد‪ .‬ﺗﻮﺻﻴﻪ ﻣﻴﺸﻮد ﺑﺮرﺳﻲ ﻧﺎﻣﻨﻈﻤﻲ ﭘﻴﭽﺸﻲ‬ ‫) ﺑﻨﺪ ‪ 6‬ﺑﺎﻻ ( ﻧﻴﺰ در ﻫﻤﻴﻦ ﺟﺪول اﻧﺠﺎم ﮔﻴﺮد‪.‬‬ ‫‪ .18‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ اﮔﺮ ﻃﺮاﺣﻲ ﺳﺎزه ﺑﺎ اﺳﺘﻔﺎده از ﺑﺎرﻫﺎي اﺳﺘﺎﺗﻴﻜﻲ ﻣﻌﺎدل اﻧﺠﺎم ﺷﺪه اﺳﺖ‪ ،‬ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﺟﺎﻧﺒﻲ ﻧﻴﺰ‬ ‫ﺑﺎﻳﺪ در ﺣﺎﻟﺖ ﺑﺎر زﻟﺰﻟﻪ اﺳﺘﺎﺗﻴﻜﻲ ﻛﻨﺘﺮل ﺷﻮد و در ﺻﻮرﺗﻲ ﻛﻪ ﻃﺮاﺣﻲ ﺳﺎزه ﺑﺎ اﺳﺘﻔﺎده از روش ﻃﻴﻔﻲ اﻧﺠﺎم ﺷﺪه‬ ‫ﺑﺎﺷﺪ‪ ،‬ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﺟﺎﻧﺒﻲ ﻧﻴﺰ ﺑﺎﻳﺪ ﺗﺤﺖ اﺛﺮ ﻃﻴﻒ ﻛﻨﺘﺮل ﺷﻮد‪.‬‬ ‫‪ .19‬در ﺻﻮرت ﻛﺎرﺑﺮد دﻳﻮار ﺑﺮﺷﻲ ﻳﺎ ﻣﻬﺎرﺑﻨﺪي ﻓﻮﻻدي در ﺳﺎزه و ﻧﻴﺎز ﺑﻪ ﻛﺎﻫﺶ آﻧﻬﺎ در ﻃﺒﻘﺎت ﺑﺎﻻﺗﺮ‪ ،‬ﺗﻮﺻﻴﻪ ﻣﻲ‬ ‫ﺷﻮد ﺣﺘﻲ اﻻﻣﻜﺎن از ﻛﺎﻫﺶ ﻧﺎﮔﻬﺎﻧﻲ ﺗﻌﺪاد زﻳﺎدي از دﻫﺎﻧﻪ ﻫﺎي دﻳﻮار ﺑﺮﺷﻲ ﻳﺎ ﻣﻬﺎرﺑﻨﺪي اﺟﺘﻨﺎب ﺷﻮد‪ .‬ﺑﻪ ﻫﺮ‬ ‫ﺣﺎل در ﺻﻮرﺗﻲ ﻛﻪ ﻛﺎﻫﺶ دﻳﻮار ﺑﺮﺷﻲ و ﻣﻬﺎرﺑﻨﺪﻳﻬﺎ ﺑﻪ ﻧﺤﻮي ﺑﺎﺷﺪ ﻛﻪ ﺳﺎزه ﻣﺸﻤﻮل ﻧﺎﻣﻨﻈﻤﻲ در ارﺗﻔﺎع ﺷﻮد‪،‬‬ ‫ﺗﺤﻠﻴﻞ ﻃﻴﻔﻲ ﺑﺎﻳﺪ اﻧﺠﺎم ﺷﻮد‪.‬‬ ‫‪ .20‬ﺟﺰﺋﻴﺎت ﭘﺎرﻣﺘﺮﻫﺎي ﻃﺮاﺣﻲ ﺳﺎزه ﻧﮕﻬﺒﺎن ﺷﺎﻣﻞ ارﺗﻔﺎع ﮔﻮد‪ ،‬ﺳﺮﺑﺎر ﺳﺎﺧﺘﻤﺎﻧﻬﺎي ﻣﺠﺎور‪ ،‬ﻓﺎﺻﻠﻪ ﺑﻴﻦ ﺧﺮﭘﺎﻫﺎ‪،‬‬ ‫زاوﻳﻪ اﺻﻄﻜﺎك داﺧﻠﻲ ﺧﺎك‪ ،‬ﭼﺴﺒﻨﺪﮔﻲ ﺧﺎك‪ ،‬وزن ﻣﺨﺼﻮص ﺧﺎك و ﻧﺤﻮه اﻧﺘﺨﺎب ﺧﺮﭘﺎي ﻣﺮﺑﻮﻃﻪ در دﻓﺘﺮﭼﻪ‬ ‫ﻣﺤﺎﺳﺒﺎت ذﻛﺮ ﺷﻮد‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪24 :‬‬

‫‪ .21‬ﺑﺮاي ﻣﺤﺎﺳﺒﻪ ﺑﺎر ﺗﻴﻐﻪ ﺑﻨﺪي‪ ،‬ﺑﺎﻳﺪ اﺑﺘﺪا در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت وزن واﺣﺪ ﺳﻄﺢ ﺗﻴﻐﻪ ﺑﻨﺪي ﻣﺤﺎﺳﺒﻪ ﺷﻮد‪ .‬در‬ ‫ﺻﻮرﺗﻲ ﻛﻪ اﻳﻦ ﻣﻘﺪار ﻛﻤﺘﺮ از ‪ 275 kg/m2‬ﺑﺎﺷﺪ‪ ،‬ﻣﻲ ﺗﻮان ﻃﺒﻖ ﺑﻨﺪ ‪ 2-2-2-6‬ﺑﺎر ﻣﻌﺎدل ﺗﻴﻐﻪ ﺑﻨﺪي را از ﺗﻘﺴﻴﻢ‬ ‫وزن ﻛﻞ ﺗﻴﻐﻪ ﻫﺎي ﻫﺮ ﻃﺒﻘﻪ ﺑﺮ ﺳﻄﺢ داﻟﻬﺎي ﺳﺎزه اي آن ﻃﺒﻘﻪ ﺑﻪ دﺳﺖ آورد‪ .‬ﺑﻪ ﻫﺮ ﺣﺎل ﺣﺪاﻗﻞ ﺑﺎر ﮔﺴﺘﺮده‬ ‫ﻣﻌﺎدل ﺗﻴﻐﻪ ﺑﻨﺪي ﺑﺎﻳﺪ ﺑﺮاﺑﺮ ‪ 100 kg/m2‬در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪.‬‬ ‫‪ .22‬در ﻣﻮرد ﺑﺎر دﻳﻮارﻫﺎي ‪ 20‬ﺳﺎﻧﺘﻴﻤﺘﺮي )ﻧﻈﻴﺮ دﻳﻮار ﭘﻴﺮاﻣﻮﻧﻲ‪ ،‬دﻳﻮار ﺑﻴﻦ واﺣﺪﻫﺎي آﭘﺎرﺗﻤﺎﻧﻲ ﻣﺠﺎور‪ ،‬دﻳﻮار‬ ‫ﭘﻴﺮاﻣﻮن ﻧﻮرﮔﻴﺮﻫﺎ‪ ،‬ﭘﻠﻪ ﻫﺎ و ‪ (....‬ﺑﺎﻳﺪ ﭘﺲ از اراﺋﻪ ﻣﺤﺎﺳﺒﺎت ﻻزم در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت‪ ،‬ﺑﺎر دﻳﻮار ﺑﻪ ﺻﻮرت ﺑﺎر‬ ‫ﺧﻄﻲ ﻣﻌﺎدل روي ﺗﻴﺮ ﺳﺎزه اﻋﻤﺎل ﺷﻮد‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪25 :‬‬

‫‪ -8‬ﻧﻜﺎت ﻛﻠﻲ درﺑﺎره ﻓﺎﻳﻞ ﻣﺪل ﻛﺎﻣﭙﻴﻮﺗﺮي ﺳﺎزه‬

‫‪ .1‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ اﻣﻜﺎﻧﺎت ﻣﻨﺎﺳﺐ ﻧﺮم اﻓﺰار ‪ ETABS2000‬و ‪ SAFE2000‬ﺑﺮاي ﻣﺪل ﺳﺎزي و ﻃﺮاﺣﻲ ﺳﺎزه ﻫﺎ وﺷﺎﻟﻮده‬ ‫ﻫﺎ‪ ،‬ﺗﻮﺻﻴﻪ اﻛﻴﺪ ﻣﻲ ﺷﻮد از اﻳﻦ ﻧﺮم اﻓﺰارﻫﺎ ﺑﺮاي ﻃﺮاﺣﻲ ﺳﺎزه و ﺷﺎﻟﻮده اﺳﺘﻔﺎده ﮔﺮدد‪.‬‬ ‫‪ .2‬در ﺻﻮرت وﺟﻮد ﻧﻴﻢ ﻃﺒﻘﻪ در ﺳﺎزه‪ ،‬اﮔﺮ در ﻧﺮم اﻓﺰار ‪ ETABS‬ﺑﻪ ﺟﺎي "ﻃﺒﻘﻪ" از ‪ Reference plane‬ﺑﺮاي‬ ‫ﻣﺪل ﺳﺎزي اﺳﺘﻔﺎده ﺷﻮد‪ ،‬ﺑﻪ ﻣﻨﻈﻮر ﺗﻮزﻳﻊ ﺻﺤﻴﺢ ﻧﻴﺮوي ﺟﺎﻧﺒﻲ در ارﺗﻔﺎع ﺳﺎزه‪ ،‬ﺑﺎﻳﺪ در ﻗﺴﻤﺖ ‪Mass Source‬‬

‫ﮔﺰﻳﻨﻪ ‪ Lump Lateral Mass at Story Levels‬ﻏﻴﺮ ﻓﻌﺎل ﺷﻮد‪.‬‬ ‫‪ .3‬در ﺻﻮرت اﺳﺘﻔﺎده از ﺿﺮﻳﺐ ﻛﺎﻫﺶ ﺑﺎر زﻧﺪه‪ ،‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﻃﺒﻖ ﺑﻨﺪ ‪ 1-8-3-6‬ﻛﺎﻫﺶ ﺑﺎر ﺑﺮاي ﺑﺎﻣﻬﺎ و‬ ‫ﭘﺎرﻛﻴﻨﮕﻬﺎ ﻣﺠﺎز ﻧﻴﺴﺖ‪ .‬ﺑﻨﺎﺑﺮاﻳﻦ ﺑﺎر زﻧﺪه اﻳﻦ ﻗﺴﻤﺘﻬﺎ ﺑﺎﻳﺪ از ﻧﻮع ‪ LIVE‬و ﺑﺎر ﻗﺴﻤﺘﻬﺎي ﻗﺎﺑﻞ ﻛﺎﻫﺶ از ﻧﻮع‬ ‫‪ Reducible Live‬ﺗﻌﺮﻳﻒ ﺷﻮد‪ .‬ﺗﻮﺻﻴﻪ ﻣﻲ ﺷﻮد از ﻛﺎﻫﺶ ﺑﺎر ﺑﺮاي ﺗﻴﺮﻫﺎ ﺻﺮﻓﻨﻈﺮ ﺷﻮد و ﺑﺮاي ﺳﺘﻮﻧﻬﺎ ﻧﻴﺰ از‬ ‫ﮔﺰﻳﻨﻪ ‪ User Defined by stories Supported‬اﺳﺘﻔﺎده ﺷﻮد و ﻣﻘﺎدﻳﺮ ﻛﺎﻫﺶ ﺑﺎر ﻃﺒﻖ درﺻﺪﻫﺎي اراﺋﻪ ﺷﺪه‬ ‫در ﺑﻨﺪ ‪ 3-8-3-6‬ﻣﺒﺤﺚ ﺷﺸﻢ اﻋﻤﺎل ﺷﻮد‪.‬‬ ‫‪ .4‬ﺑﺎر ﻣﺮده و زﻧﺪه ﭘﻠﻪ ﻫﺎ و رﻣﭙﻬﺎ در ﻣﺪل ﺳﺎزه ﺑﻪ ﻃﻮر ﻣﻨﺎﺳﺐ اﻋﻤﺎل ﮔﺮدد‪.‬‬ ‫‪ .5‬در ﺣﺎﻟﺘﻲ ﻛﻪ از ﺗﻴﺮﭼﻪ دوﺑﻞ در ﺳﻘﻒ ﺗﻴﺮﭼﻪ ﺑﻠﻮك اﺳﺘﻔﺎده ﻣﻲ ﺷﻮد‪ ،‬اﺛﺮ اﺿﺎﻓﻪ وزن ﺑﺘﻦ ﺗﻴﺮﭼﻪ دوﺑﻞ در ﺑﺎر‬ ‫ﻣﺮده ﺳﻘﻒ آن ﻣﺤﺪوده‪ ،‬در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪.‬‬ ‫‪ .6‬ﻛﺎﻫﺶ وزن و ﺟﺮم ﺣﺠﻤﻲ ﻣﺼﺎﻟﺢ در ﻓﺎﻳﻞ ﺳﺎزه ﻗﺎﺑﻞ ﭘﺬﻳﺮش ﻧﻴﺴﺖ‪ .‬اﺻﻮﻻ ﻛﺎﻫﺶ وزن ﻓﻘﻂ ﺑﺮاي ﺗﻴﺮﻫﺎي ﺑﺘﻨﻲ‬ ‫)ﺟﻬﺖ ﺣﺬف وزن ﻗﺴﻤﺖ ﻣﺸﺘﺮك ﺑﺎ داﻟﻬﺎ( ﻗﺎﺑﻞ ﺗﻮﺟﻴﻪ اﺳﺖ ﻛﻪ ﺑﺎﻳﺪ از ﮔﺰﻳﻨﻪ ‪ weight property modifier‬ﻳﺎ‬ ‫‪ mass property modifier‬اﺳﺘﻔﺎده ﺷﻮد و رﻳﺰ ﻣﺤﺎﺳﺒﺎت آن ﻧﻴﺰ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ذﻛﺮ ﺷﻮد‪ .‬ﻟﻴﻜﻦ ﺑﻪ ﻃﻮر‬ ‫ﻛﻠﻲ ﺗﻮﺻﻴﻪ اﻛﻴﺪ ﻣﻲ ﺷﻮد ﺑﺮاي در ﻧﻈﺮ ﮔﺮﻓﺘﻦ اﺛﺮات ﺑﺎرﻫﺎي ﻣﺮده ﭘﻴﺶ ﺑﻴﻨﻲ ﻧﺸﺪه‪ ،‬از ﻛﺎﻫﺶ وزن اﺳﻜﻠﺖ‬ ‫ﺻﺮﻓﻨﻈﺮ ﺷﻮد‪.‬‬ ‫‪ .7‬درﺻﺪ ﻣﺸﺎرﻛﺖ ﺑﺎر زﻧﺪه و ﺑﺎر ﺑﺮف در ﻣﺤﺎﺳﺒﻪ ﻧﻴﺮوي ﺟﺎﻧﺒﻲ زﻟﺰﻟﻪ ﻃﺒﻖ ﺟﺪول ‪ 1-7-6‬ﻣﺒﺤﺚ ﺷﺸﻢ ﺗﻌﻴﻴﻦ‬ ‫ﺷﻮد‪ .‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﺑﺮاي ﻗﺴﻤﺘﻬﺎي ﺗﺠﺎري‪ ،‬اﻳﻦ درﺻﺪ ﺑﺮاﺑﺮ ‪ %40‬اﺳﺖ‪.‬‬ ‫‪ .8‬در ﺻﻮرت اﺳﺘﻔﺎده از روش ﺗﺤﻠﻴﻞ اﺳﺘﺎﺗﻴﻜﻲ ﻣﻌﺎدل‪ ،‬در ﺣﺎﻟﺘﻬﺎﻳﻲ ﻛﻪ زﻣﺎن ﺗﻨﺎوب اﺻﻠﻲ ﺳﺎزه ﺑﻴﺸﺘﺮ از ‪ 0/7‬ﺛﺎﻧﻴﻪ‬ ‫اﺳﺖ‪ ،‬ﺑﺎﻳﺪ اﺛﺮ ﻧﻴﺮوي ﺷﻼﻗﻲ ﻧﻴﺰ درﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪ .‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ در ﺻﻮرت اﺳﺘﻔﺎده از ﮔﺰﻳﻨﻪ ‪USER‬‬

‫‪ COEFFICIENT‬در ﻧﺮم اﻓﺰارﻫﺎ‪ ،‬اﺛﺮ ﻧﻴﺮوي ﺷﻼﻗﻲ در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﻧﻤﻲ ﺷﻮد و در اﻳﻦ ﺣﺎﻟﺘﻬﺎ ﺑﺎﻳﺪ از ﮔﺰﻳﻨﻪ‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪26 :‬‬

‫‪ UBC94‬ﺑﻪ ﻧﺤﻮي اﺳﺘﻔﺎده ﺷﻮد ﻛﻪ ﻧﺘﺎﻳﺞ آن ﻣﻨﻄﺒﻖ ﺑﺮ ﻣﺒﺤﺚ ﺷﺸﻢ ﺑﺎﺷﺪ‪ .‬ﺑﻪ اﻳﻦ ﻣﻨﻈﻮر ﺑﺎﻳﺪ ﻃﺒﻖ ﺷﻜﻞ زﻳﺮ‬ ‫زﻣﺎن ﺗﻨﺎوب ﻣﺤﺎﺳﺒﻪ ﺷﺪه ‪ ،T‬ﺿﺮﻳﺐ رﻓﺘﺎر ‪ R‬و ﺿﺮﻳﺐ ‪ Z‬ﺑﺮاﺑﺮ ﺷﺘﺎب ﻣﺒﻨﺎي زﻣﻴﻦ )‪ (A‬ﻃﺒﻖ ﺿﻮاﺑﻂ ﻣﺒﺤﺚ ﺷﺸﻢ‬ ‫ﺑﺮاي ﻫﺮ ﺳﺎزه ﻣﺤﺎﺳﺒﻪ و ﻣﻌﺮﻓﻲ ﺷﻮﻧﺪ‪ .‬ﻫﻤﭽﻨﻴﻦ ﺟﻬﺖ ﻫﻤﺎﻫﻨﮕﻲ ﻧﺘﺎﻳﺞ ﺑﺎ ﺑﺮش ﭘﺎﻳﻪ و ﻧﻴﺮوي ﺷﻼﻗﻲ ﺣﺎﺻﻞ از‬ ‫ﻣﺒﺤﺚ ﺷﺸﻢ‪ ،‬ﺑﺎﻳﺪ ﺿﺮﻳﺐ )‪ S (Site coefficient‬در ﻣﻨﻮي ﺑﺎرﮔﺬاري ‪ UBC-94‬ﻫﻤﻮاره ﺑﺮاﺑﺮ واﺣﺪ ﻣﻌﺮﻓﻲ ﺷﻮد و‬ ‫ﺿﺮﻳﺐ اﻫﻤﻴﺖ ﻃﺒﻖ راﺑﻄﻪ زﻳﺮ ﻣﺤﺎﺳﺒﻪ و ﻣﻌﺮﻓﻲ ﺷﻮد‪:‬‬ ‫) ‪IUBC −94 = I IRAN ×0.8 × ( S IRAN + 1) × (Ts2 / 3‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫دا ﻧ ﻮ‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫ﺻﻔﺤﻪ‪27 :‬‬

‫اﻟﺒﺘﻪ ﺑﺎﻳﺪ ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ اﻳﻦ ﻣﻌﺎدل ﺳﺎزي ﻓﻘﻂ ﺑﺮاي ﺣﺎﻟﺘﻬﺎﻳﻲ ﻛﻪ زﻣﺎن ﺗﻨﺎوب اﺻﻠﻲ ﺳﺎزه ﺑﻴﺸﺘﺮ از ‪ 0/7‬ﺛﺎﻧﻴﻪ‬ ‫اﺳﺖ و ﻓﻘﻂ ﺑﺮاي ﺧﺎك ﻧﻮع ‪ II‬و ‪ III‬ﺻﺤﻴﺢ اﺳﺖ ﻛﻪ ﻣﻌﻤﻮﻻ در ﺑﻴﺸﺘﺮ ﺣﺎﻟﺘﻬﺎي ﻋﻤﻠﻲ ﻗﺎﺑﻞ اﺳﺘﻔﺎده ﺧﻮاﻫﺪ ﺑﻮد‪.‬‬ ‫ﺑﻪ ﻋﻨﻮان ﻣﺜﺎل ﺑﺮاي ﺧﺎك ﻧﻮع ‪ III‬و ﺿﺮﻳﺐ اﻫﻤﻴﺖ ‪: 1/0‬‬ ‫‪IUBC −94 = 1× 0.8 × (1.75 + 1) × (0.7 2 / 3 ) = 1.734‬‬

‫و ﺑﺮاي ﺧﺎك ﻧﻮع ‪ II‬و ﺿﺮﻳﺐ اﻫﻤﻴﺖ ‪: 1/0‬‬ ‫‪IUBC −94 = 1× 0.8 × (1.5 + 1) × (0.52 / 3 ) = 1.26‬‬

‫ﺑﻪ ﻫﺮ ﺣﺎل ﺗﻮﺻﻴﻪ ﻣﻲ ﺷﻮد ﻫﻤﻮاره ﭘﺲ از اﻧﺠﺎم ﺗﺤﻠﻴﻞ ﻛﺎﻣﭙﻴﻮﺗﺮي‪ ،‬ﻣﻘﺎدﻳﺮ ﺑﺮش ﭘﺎﻳﻪ و ﻧﻴﺮوي ﺷﻼﻗﻲ ﺑﺎ‬ ‫ﻣﺤﺎﺳﺒﺎت دﺳﺘﻲ ﻛﻨﺘﺮل ﺷﻮد‪.‬‬ ‫‪ .9‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﺗﺮﻛﻴﺒﺎت ﺑﺎر ﻣﻮرد اﺳﺘﻔﺎده در ﻗﺴﻤﺖ ﻃﺮاﺣﻲ‪ ،‬ﻛﺎﻣﻼ ﻣﻨﻄﺒﻖ ﺑﺮ آﻳﻴﻦ ﻧﺎﻣﻪ ﻃﺮاﺣﻲ ﻣﻮرد اﺳﺘﻔﺎده‬ ‫ﺑﺎﺷﺪ‪.‬‬ ‫‪ .10‬در ﻓﺎﻳﻞ ﺳﺎزه ﺑﺎﻳﺪ ﺧﺮﭘﺸﺘﻪ و اﺗﺎق ﻛﻨﺘﺮل آﺳﺎﻧﺴﻮر‪ ،‬ﻫﻤﺎﻫﻨﮓ ﺑﺎ ﻧﻘﺸﻪ ﻣﻌﻤﺎري ﻣﺪل و ﺑﺎرﮔﺬاري ﺷﻮﻧﺪ‪.‬‬ ‫‪ .11‬ﺑﺎر آﺳﺎﻧﺴﻮر و ﭘﻠﻪ ﻫﺎ ﺑﻪ ﻧﺤﻮ ﻣﻨﺎﺳﺒﻲ ﺑﻪ ﺗﻜﻴﻪ ﮔﺎه ﻫﺎي ﻣﺮﺑﻮﻃﻪ اﻋﻤﺎل ﺷﻮد‪ .‬ﺣﺪاﻗﻞ ﺑﺎر آﺳﺎﻧﺴﻮر ﺑﺮاﺑﺮ ‪ 1/5‬ﺗﻦ و‬ ‫ﺑﺎ اﻋﻤﺎل ﺿﺮﻳﺐ ﺿﺮﺑﻪ ‪ 2‬در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪.‬‬ ‫‪ .12‬در ﺻﻮرت اﻧﺠﺎم ﺗﺤﻠﻴﻞ ﻃﻴﻔﻲ‪ ،‬رﻋﺎﻳﺖ ﺑﻨﺪ ‪ 2-2-6-2-7-6‬درﺑﺎره ﻣﻘﺪار درﺻﺪ ﻣﺸﺎرﻛﺖ ﺟﺮﻣﻲ ﺣﺎﺻﻞ از‬ ‫ﺗﺤﻠﻴﻞ )‪ (Mass Participation Ratio‬در ﺟﻬﺖ ﻫﺎي ‪ SUMUX, SUMUY, SUMRZ‬ﻛﻨﺘﺮل ﺷﻮد‪ .‬ﺑﻪ ﻫﺮ ﺣﺎل‬ ‫درﺻﺪ ﻣﺸﺎرﻛﺖ ﺟﺮﻣﻲ ﻛﻤﺘﺮ از ‪ %90‬ﻗﺎﺑﻞ ﻗﺒﻮل ﻧﻴﺴﺖ‪.‬‬ ‫‪ .13‬ﺑﺮاي ﺳﺎﺧﺘﻤﺎن ﻫﺎي ﺑﺎ اﻫﻤﻴﺖ زﻳﺎد‪ ،‬ﺧﻴﻠﻲ زﻳﺎد و ﻳﺎ ﺑﻠﻨﺪﺗﺮ از ‪ 50‬ﻣﺘﺮ و ﻳﺎ ﺑﻴﺸﺘﺮ از ‪ 15‬ﻃﺒﻘﻪ‪ ،‬ﻛﻨﺘﺮل ﺳﺎزه ﺑﺮاي‬ ‫زﻟﺰﻟﻪ ﺳﻄﺢ ﺑﻬﺮه ﺑﺮداري‪ ،‬از ﻧﻈﺮ ﺗﻼﺷﻬﺎي اﻳﺠﺎد ﺷﺪه در اﻋﻀﺎي ﺳﺎزه اي و ﻛﻨﺘﺮل ﺗﻐﻴﻴﺮ ﺷﻜﻞ ﺟﺎﻧﺒﻲ‪ ،‬ﻃﺒﻖ‬ ‫ﺿﻮاﺑﻂ ﺑﺨﺶ ‪ 9-3-7-6‬اﻧﺠﺎم ﮔﻴﺮد‪ .‬ﺑﻪ اﻳﻦ ﻣﻨﻈﻮر ﺑﺎﻳﺪ ﻓﺎﻳﻞ ﺟﺪاﮔﺎﻧﻪ اي ﺗﻬﻴﻪ و در ﻟﻮح ﻓﺸﺮده ﭘﺮوژه ﺑﻪ ﺳﺎزﻣﺎن‬ ‫ﺗﺤﻮﻳﻞ ﺷﻮد‪.‬‬ ‫‪ .14‬در ﺣﺎﻟﺘﻬﺎﻳﻲ ﻛﻪ ﻫﻢ ﺗﺤﻠﻴﻞ ﻃﻴﻔﻲ و ﻫﻢ ﺗﺮﻛﻴﺐ ﻧﻴﺮو ﻫﺎي ﻟﺮزه اي در دو ﺟﻬﺖ ﻣﺘﻌﺎﻣﺪ )‪ (%100-%30‬ﻻزم‬ ‫اﺳﺖ‪ ،‬ﻃﺒﻖ ﻳﻜﻲ از دو روش ذﻳﻞ ﻋﻤﻞ ﺷﻮد‪:‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪28 :‬‬

‫اﻟﻒ( در اﻳﻦ ﺣﺎﻟﺖ ﺑﺎﻳﺪ در ﻫﻨﮕﺎم ﺗﻌﺮﻳﻒ ﻃﻴﻒ در ﻳﻚ ﺟﻬﺖ )‪ ،(U1‬ﻃﻴﻒ ﺟﻬﺖ دﻳﮕﺮ)‪ (U2‬ﻧﻴـﺰ ﺑـﺎ ﺿـﺮﻳﺐ ‪%30‬‬ ‫ﺗﻌﺮﻳـﻒ ﺷـﻮد و ﺑـﺮاي ﻧـﻮع ﺗﺮﻛﻴـﺐ ﺑـﺎر دو ﺟﻬـﺖ )‪ (Directional Combination‬از ﮔﺰﻳﻨـﻪ ‪ ABS‬ﺑـﺎ ﺿـﺮﻳﺐ‬ ‫‪ Orthogonal SF=1.0‬اﺳﺘﻔﺎده ﺷﻮد‪ .‬در اﻳﻦ ﺣﺎﻟﺖ‪ ،‬ﻫﻤﭙﺎﻳﮕﻲ ﺑﺎ ﺑﺮش ﭘﺎﻳﻪ ﻧﻴﺰ ﺑﺎ در ﻧﻈﺮ ﮔﺮﻓﺘﻦ ﺿﺮاﺋﺐ ‪ %100‬و‬ ‫‪ %30‬اﻧﺠﺎم ﻣﻲ ﺷﻮد و ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ اﻳﻨﻜﻪ ﺗﺮﻛﻴﺐ دو ﺟﻬﺖ در ﺣﺎﻟﺖ ﺑﺎر ﻃﻴﻒ اﻧﺠﺎم ﺷﺪه اﺳﺖ‪ ،‬اﺣﺘﻴﺎﺟﻲ ﺑﻪ ﺗﻐﻴﻴـﺮ‬ ‫در ﺗﺮﻛﻴﺐ ﺑﺎرﻫﺎ ﻧﻴﺴﺖ‪.‬‬

‫ب( ﻳﻚ ﺣﺎﻟﺖ ﺑﺎر ﻃﻴﻒ در ﺟﻬﺖ ﻃﻮﻟﻲ )ﺑﻪ ﻋﻨﻮان ﻣﺜﺎل ﺑﺎ ﻧﺎم ‪ (specX‬و ﻳﻚ ﺣﺎﻟﺖ ﺑﺎر ﻃﻴـﻒ در ﺟﻬـﺖ ﻋﺮﺿـﻲ‬ ‫)ﺑﻪ ﻋﻨﻮان ﻣﺜﺎل ﺑﺎ ﻧﺎم ‪ (specY‬ﺗﻌﺮﻳﻒ ﺷﺪه و ﺑﻪ ﻃﻮر ﻣﻨﺎﺳﺐ ﺑﺎ ﺑﺮش ﭘﺎﻳـﻪ اﺳـﺘﺎﺗﻴﻜﻲ ﻣﺮﺑـﻮط ﺑـﻪ ﺟﻬـﺖ ﻃﻴـﻒ‬ ‫ﻫﻤﭙﺎﻳﻪ ﺷﻮد‪ .‬در اﻳﻦ ﺣﺎﻟﺖ در ﺗﺮﻛﻴﺐ ﺑﺎرﻫﺎ‪ ،‬ﺿﺮﻳﺐ ‪ %100‬و ‪ %30‬در ﺿﺮاﻳﺐ ﺗﺮﻛﻴـﺐ ﺑـﺎر ﺗـﺎﺛﻴﺮ داده ﺷـﻮﻧﺪ و‬ ‫ﺗﺮﻛﻴﺐ ﻧﻴﺮوي زﻟﺰﻟﻪ دو ﺟﻬﺖ در ﺗﺮﻛﻴﺐ ﺑﺎرﻫﺎ در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮﻧﺪ‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪29 :‬‬

‫‪ .15‬در ﺻﻮرت ﻧﺼﺐ ﻫﺮﮔﻮﻧﻪ ﺗﺠﻬﻴﺰات در ارﺗﺒﺎط ﺑﺎ ﺗﺎﺳﻴﺴﺎت ﺑﺮق و ﻣﻜﺎﻧﻴﻚ ﻧﻈﻴﺮ ﭼﻴﻠﺮﻫﺎ‪ ،‬ﻣﻨﺎﺑﻊ آب‪ ،‬دﻳﺰل‬ ‫ژﻧﺮاﺗﻮر‪ ،‬و ‪ ....‬ﺑﺮ روي ﺑﺎم ﻳﺎ ﻫﺮ ﺳﻘﻒ ﺳﺎزه اي دﻳﮕﺮ‪ ،‬ﺑﺎرﻫﺎي اﺳﺘﺎﺗﻴﻜﻲ و دﻳﻨﺎﻣﻴﻜﻲ ﻧﺎﺷﻲ از ﻛﺎرﻛﺮد ﺗﺠﻬﻴﺰات ﻳﺎ‬ ‫ارﺗﻌﺎﺷﺎت زﻟﺰﻟﻪ در ﻓﺎﻳﻞ ﺳﺎزه اﻋﻤﺎل ﺷﻮد‪ .‬ﺑﻪ ﻫﺮ ﺣﺎل‪ ،‬ﺣﺪاﻗﻞ ﺑﺎر زﻧﺪه ﮔﺴﺘﺮده در ﻓﻀﺎي ﻣﻮﺗﻮرﺧﺎﻧﻪ ﻃﺒﻖ ﺿﻮاﺑﻂ‬ ‫ﻣﺒﺤﺚ ﺷﺸﻢ ﺑﺮاﺑﺮ ‪ 750 kg/m2‬در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪.‬‬ ‫‪ .16‬در ﻣﻮرد ﺳﺎﺧﺘﻤﺎن ﻫﺎﻳﻲ ﻛﻪ در ارﺗﻔﺎع داراي دو ﺳﻴﺴﺘﻢ ﻣﺨﺘﻠﻒ ﺑﺎرﺑﺮ ﺟﺎﻧﺒﻲ ﻫﺴﺘﺪ )ﻣﺎﻧﻨﺪ ﺳﺎﺧﺘﻤﺎن ﻫﺎي ﺑﺎ‬ ‫ﺳﻴﺴﺘﻢ ﻗﺎب ﺧﻤﺸﻲ ﻛﻪ در ﻃﺒﻘﺎت زﻳﺮزﻣﻴﻦ داراي دﻳﻮار ﺑﺮﺷﻲ ﭘﻴﺮاﻣﻮﻧﻲ ﻫﺴﺘﻨﺪ( ﺑﺎﻳﺪ ﺑﺎرﮔﺬاري ﻟﺮزه‬ ‫اي ﺳﺎزه ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻣﻔﺎد ﺑﻨﺪ ‪ 3-8-5-2-7-6‬اﻧﺠﺎم ﮔﻴﺮد‪ .‬ﺑﺮاي ﻣﺤﺎﺳﺒﻪ زﻣﺎن ﺗﻨﺎوب اﺻﻠﻲ ﺳﺎزه ﺑﺎﻳﺪ از راﺑﻄﻪ‬ ‫ﺗﺠﺮﺑﻲ ﻛﻪ ﻛﻤﺘﺮﻳﻦ ﻣﻘﺪار را اراﺋﻪ ﻣﻴﻜﻨﺪ اﺳﺘﻔﺎده ﺷﻮد و ﻣﺤﺎﺳﺒﻪ ﺑﺮش ﭘﺎﻳﻪ ﺑﺮ ﻣﺒﻨﺎي ﻛﻮﭼﻜﺘﺮﻳﻦ ﺿﺮﻳﺐ رﻓﺘﺎر دو‬ ‫ﺳﻴﺴﺘﻢ اﻧﺠﺎم ﺷﻮد‪ .‬در اﻳﻦ ﺣﺎﻟﺖ ﺑﺮاي ﻣﺤﺎﺳﺒﻪ زﻣﺎن ﺗﻨﺎوب اﺻﻠﻲ ﺳﺎزه‪ ،‬ارﺗﻔﺎع ﺳﺎزه از روي ﺷﺎﻟﻮده ﺗﺎ آﺧﺮﻳﻦ‬ ‫ﺳﻘﻒ ﺳﺎزه اي در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﻣﻲ ﺷﻮد‪.‬‬ ‫‪ .17‬ﻃﺒﻖ ﺑﻨﺪ ‪-1-3-7-6‬پ در ﻣﻨﺎﻃﻖ ﺑﺎ ﺧﻄﺮ زﻟﺰﻟﻪ ﺧﻴﺰي ﻧﺴﺒﻲ ﺧﻴﻠﻲ زﻳﺎد‪ ،‬ﺑﺮاي ﺳﺎﺧﺘﻤﺎن ﻫﺎي "ﺑﺎ اﻫﻤﻴﺖ‬ ‫ﺧﻴﻠﻲ زﻳﺎد" ﺑﺎﻳﺪ ﻓﻘﻂ از ﺳﻴﺴﺘﻢ ﻫﺎﻳﻲ ﻛﻪ در ﺟﺪول ‪ 6-7-6‬ﻋﻨﻮان "وﻳﮋه" دارﻧﺪ اﺳﺘﻔﺎده ﺷﻮد‪ .‬ﻫﻤﭽﻨﻴﻦ در‬ ‫ﺳﺎﺧﺘﻤﺎن ﻫﺎي ﺑﺎ ﺑﻴﺸﺘﺮ از ‪ 15‬ﻃﺒﻘﻪ و ﻳﺎ ﺑﻠﻨﺪﺗﺮ از ‪ 50‬ﻣﺘﺮ‪ ،‬ﻃﺒﻖ ﺑﻨﺪ ‪-1-3-7-6‬ب اﺳﺘﻔﺎده از ﻗﺎب ﺧﻤﺸﻲ ﻳﺎ‬ ‫ﺳﻴﺴﺘﻢ دوﮔﺎﻧﻪ اﻟﺰاﻣﻲ اﺳﺖ‪.‬‬ ‫‪ .18‬ﺑﺮاي ﻣﺤﺎﺳﺒﻪ ﺻﺤﻴﺢ ﺟﺮم ﻣﻮﺛﺮ ﻃﺒﻘﻪ آﺧﺮ )ﺑﺎم( در ﻣﺤﺎﺳﺒﺎت ﻧﻴﺮوي زﻟﺰﻟﻪ‪ ،‬ﺑﺎﻳﺪ ﻧﺼﻒ وزن دﻳﻮارﻫﺎي‬ ‫ﭘﻴﺮاﻣﻮﻧﻲ ﺑﺮ ﺗﻴﺮﻫﺎي اﻳﻦ ﺗﺮاز وارد ﺷﻮد‪ .‬ﻣﻌﻤﻮﻻ ﻃﺮاﺣﺎن اﻳﻦ ﺑﺎر را در ﻳﻚ ﺣﺎﻟﺖ ﺑﺎر از ﻧﻮع ‪ other‬ﺑﻪ ﺳﺎزه‬ ‫اﻋﻤﺎل ﻣﻴﻜﻨﻨﺪ‪ .‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﻋﻼوه ﺑﺮ وزن دﻳﻮار ﭘﻴﺮاﻣﻮﻧﻲ‪ ،‬ﺑﺎﻳﺪ ﻧﺼﻒ وزن ﺗﻴﻐﻪ ﺑﻨﺪي ﻃﺒﻘﻪ آﺧﺮ ﻧﻴﺰ در اﻳﻦ‬ ‫ﺣﺎﻟﺖ ﺑﺎر ﺑﻪ ﺻﻮرت ﺑﺎر ﮔﺴﺘﺮده ﻣﻌﺎدل ﺑﺮ داﻟﻬﺎي ﺗﺮاز آﺧﺮ )ﺑﺎم( اﻋﻤﺎل ﺷﻮد‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫دا ﻧ ﻮ‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫ﺻﻔﺤﻪ‪30 :‬‬

‫‪ -9‬ﻧﻜﺎت ﻣﻬﻢ در ﻓﺎﻳﻞ ﻣﺪل ﻛﺎﻣﭙﻴﻮﺗﺮي ﺳﺎزه ﻫﺎي ﺑﺘﻨﻲ‬

‫‪ .1‬در ﻣﻮرد ﺷﻜﻞ ﭘﺬﻳﺮي ﺗﻴﺮﻫﺎ و ﺳﺘﻮﻧﻬﺎ‪ ،‬رﻋﺎﻳﺖ ﻣﻮارد ذﻳﻞ ﺿﺮوري اﺳﺖ‪:‬‬ ‫اﻟﻒ( ﺷﻜﻞ ﭘﺬﻳﺮي ﺳﺘﻮﻧﻬﺎ و ﺗﻴﺮﻫﺎي اﺻﻠﻲ )ﺗﻴﺮﻫﺎﻳﻲ ﻛﻪ از ﻫﺮ دو ﻃﺮف ﺑﻪ ﺳﺘﻮن ﻣﺘﺼﻞ ﻫﺴﺘﺪ( ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺷﻜﻞ‬ ‫ﭘﺬﻳﺮي ﻓﺮض ﺷﺪه ﺑﺮاي ﺳﻴﺴﺘﻢ ﺑﺎرﺑﺮ ﺟﺎﻧﺒﻲ )ﺷﻜﻞ ﭘﺬﻳﺮ ﻣﻌﻤﻮﻟﻲ‪ ،‬ﻣﺘﻮﺳﻂ و زﻳﺎد( ﺗﻌﻴﻴﻦ ﺷﻮد‪.‬‬ ‫)‪(Sway ordinary, Sway intermediate, Sway special‬‬ ‫ب( ﺷﻜﻞ ﭘﺬﻳﺮي ﺗﻴﺮﻫﺎي ﻛﻨﺴﻮل و ﺗﻴﺮﻫﺎي ﻓﺮﻋﻲ )ﺗﻴﺮﻫﺎﻳﻲ ﻛﻪ از ﻳﻚ ﻃﺮف ﻳﺎ ﻫﺮ دو ﻃﺮف ﺑﻪ ﺗﻴﺮ ﻣﺘﺼﻞ‬ ‫ﻫﺴﺘﺪ( ازﻧﻮع ﺷﻜﻞ ﭘﺬﻳﺮ ﻣﻌﻤﻮﻟﻲ )‪ (sway ordinary‬ﺗﻌﻴﻴﻦ ﺷﻮد‪.‬‬ ‫‪ .2‬ﺑﺮاي در ﻧﻈﺮ ﮔﺮﻓﺘﻦ اﺛﺮ ﺗﺮك ﺧﻮردﮔﻲ در ﺗﻴﺮﻫﺎ و ﺳﺘﻮﻧﻬﺎي ﺑﺘﻨﻲ‪ ،‬ﺑﻪ ﻧﻜﺎت زﻳﺮ ﺗﻮﺟﻪ ﺷﻮد‪:‬‬ ‫اﻟﻒ( ﺑﺮاي ﺗﺤﻠﻴﻞ و ﻃﺮاﺣﻲ ﺳﺎزه و ﻛﻨﺘﺮل "ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﺟﺎﻧﺒﻲ ﻧﺴﺒﻲ واﻗﻌﻲ ﻃﺮح" ﺿﺮاﺋﺐ ﺗﺮك ﺧﻮردﮔﻲ‬ ‫ﺳﺨﺘﻲ ﺧﻤﺸﻲ ﺳﺘﻮﻧﻬﺎ در ﻫﺮ دو ﺟﻬﺖ ﺑﺮاﺑﺮ ‪ 0/7‬و ﺑﺮاي ﺗﻴﺮﻫﺎ ﺑﺮاﺑﺮ ‪ 0/35‬در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪ .‬ﻫﻤﭽﻨﻴﻦ ﺑﺮاي‬ ‫ﺗﻴﺮﻫﺎ ﺿﺮﻳﺐ ﺗﺮك ﺧﻮردﮔﻲ ﺳﺨﺘﻲ ﭘﻴﭽﺸﻲ‪ ،‬ﻃﺒﻖ ﺿﻮاﺑﻂ ﺗﻔﺴﻴﺮ آﻳﻴﻦ ﻧﺎﻣﻪ ﺑﺘﻦ اﻳﺮان‪ ،‬ﺑﺮاﺑﺮ ‪ 0/15‬اﻋﻤﺎل ﮔﺮدد‪.‬‬ ‫اﻳﻦ ﺿﺮﻳﺐ ﺑﺎﻋﺚ ﻛﺎﻫﺶ ﻗﺎﺑﻞ ﺗﻮﺟﻪ ﻟﻨﮕﺮ ﭘﻴﭽﺸﻲ وارد ﺑﺮ ﺗﻴﺮﻫﺎ ﺷﺪه و ﺳﻬﻮﻟﺖ ﺑﻴﺸﺘﺮي در ﻃﺮاﺣﻲ آرﻣﺎﺗﻮر‬ ‫ﭘﻴﭽﺸﻲ و ﺑﺮﺷﻲ ﺗﻴﺮ اﻳﺠﺎد ﻣﻴﻨﻤﺎﻳﺪ‪.‬‬ ‫ب( ﺑﺮاي ﻣﺤﺎﺳﺒﻪ زﻣﺎن ﺗﻨﺎوب ﺗﺤﻠﻴﻠﻲ ﺳﺎزه )در ﺻﻮرت ﻧﻴﺎز ﺑﻪ اﺳﺘﻔﺎده از آن( ﺿﺮاﺋﺐ ﺗﺮك ﺧﻮردﮔﻲ ﺳﺨﺘﻲ‬ ‫ﺧﻤﺸﻲ ﺳﺘﻮﻧﻬﺎ در ﻫﺮ دو ﺟﻬﺖ ﺑﺮاﺑﺮ ‪ 1/0‬و ﺑﺮاي ﺗﻴﺮﻫﺎ ﺑﺮاﺑﺮ ‪ 0/5‬در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪ .‬در ﺻﻮرﺗﻲ ﻛﻪ از زﻣﺎن‬ ‫ﺗﻨﺎوب ﺗﺤﻠﻴﻠﻲ ﺳﺎزه ﺑﺮاي ﻣﺤﺎﺳﺒﻪ ﺑﺮش ﭘﺎﻳﻪ ﻛﻨﺘﺮل ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﺟﺎﻧﺒﻲ )ﻃﺒﻖ ﺗﺒﺼﺮه ﺑﻨﺪ ‪ 4-2-3-7-6‬ﻣﺒﺤﺚ‬ ‫ﺷﺸﻢ( اﺳﺘﻔﺎده ﺷﻮد‪ ،‬ﻧﺤﻮه ﻣﺤﺎﺳﺒﻪ ﺑﺮش ﭘﺎﻳﻪ و رﻳﺰ ﻣﺤﺎﺳﺒﺎت آن ﻧﻴﺰ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ذﻛﺮ ﮔﺮدد‪ .‬ﺗﻮﺟﻪ‬ ‫ﺷﻮد ﻛﻪ در ﺻﻮرت اﺳﺘﻔﺎده از زﻣﺎن ﺗﻨﺎوب ﺗﺤﻠﻴﻠﻲ در ﻛﻨﺘﺮل ﺗﻐﻴﻴﺮ ﺷﻜﻞ‪ ،‬اﮔﺮ ﻣﻘﺪار زﻣﺎن ﺗﻨﺎوب ﺗﺤﻠﻴﻠﻲ ﺳﺎزه‬ ‫ﺑﻴﺶ از ‪ 0/7‬ﺛﺎﻧﻴﻪ ﺑﺎﺷﺪ‪ ،‬ﻣﻘﺪار ﻣﺠﺎز ﺗﻐﻴﻴﺮ ﺷﻜﻞ ﺟﺎﻧﺒﻲ ﻧﺴﺒﻲ ﻃﺮح ﺑﻪ ‪ 0/02‬ﻣﺤﺪود ﮔﺮدد‪) .‬ﺣﺘﻲ اﮔﺮ زﻣﺎن‬ ‫ﺗﻨﺎوب ﺗﺠﺮﺑﻲ ﺳﺎزه ﻛﻤﺘﺮ از ‪ 0/7‬ﺛﺎﻧﻴﻪ ﺑﺎﺷﺪ(‬ ‫پ( ﺑﺮاي ﻣﺤﺎﺳﺒﻪ "ﺗﻐﻴﻴﺮ ﻣﻜﺎن ﺟﺎﻧﺒﻲ ﻧﺴﺒﻲ ﺑﻬﺮه ﺑﺮداري" ﺗﺤﺖ اﺛﺮ زﻟﺰﻟﻪ ﺳﻄﺢ ﺑﻬﺮه ﺑﺮداري‪ ،‬ﺿﺮاﺋﺐ ﺗﺮك‬ ‫ﺧﻮردﮔﻲ ﺳﺨﺘﻲ ﺧﻤﺸﻲ ﺳﺘﻮﻧﻬﺎ در ﻫﺮ دو ﺟﻬﺖ ﺑﺮاﺑﺮ ‪ 1/0‬و ﺑﺮاي ﺗﻴﺮﻫﺎ ﺑﺮاﺑﺮ ‪ 0/5‬در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪.‬‬ ‫‪ .3‬ﻛﻠﻴﻪ اﺗﺼﺎﻻت در ﺳﺎزه ﻫﺎي ﺑﺘﻨﻲ ﻳﻜﭙﺎرﭼﻪ ﺑﺎﻳﺪ از ﻧﻮع ﮔﻴﺮدار ﺑﺎﺷﺪ و اﺗﺼﺎل ﻣﻔﺼﻠﻲ ﻣﺠﺎز ﻧﻴﺴﺖ‪ .‬ﺟﻬﺖ ﻛﺎﻫﺶ‬ ‫ﻟﻨﮕﺮ ﭘﻴﭽﺸﻲ وارد ﺑﺮ ﺗﻴﺮﻫﺎي ﺑﺘﻨﻲ‪ ،‬ﻃﺒﻖ ﺿﻮاﺑﻂ ﺗﻔﺴﻴﺮ آﻳﻴﻦ ﻧﺎﻣﻪ ﺑﺘﻦ اﻳﺮان‪ ،‬ﺿﺮﻳﺐ اﺻﻼح ﺳﺨﺘﻲ ﭘﻴﭽﺸﻲ‬ ‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪31 :‬‬

‫ﺑﺮاﺑﺮ ‪ 0/15‬ﺑﺮ ﻛﻠﻴﻪ ﺗﻴﺮﻫﺎ اﻋﻤﺎل ﮔﺮدد‪ .‬اﻳﻦ ﺿﺮﻳﺐ ﺑﺎﻋﺚ ﻛﺎﻫﺶ ﻗﺎﺑﻞ ﺗﻮﺟﻪ ﻟﻨﮕﺮ ﭘﻴﭽﺸﻲ وارد ﺑﺮ ﺗﻴﺮﻫﺎ ﺷﺪه و‬ ‫ﺳﻬﻮﻟﺖ ﺑﻴﺸﺘﺮي در ﻃﺮاﺣﻲ آرﻣﺎﺗﻮر ﭘﻴﭽﺸﻲ و ﺑﺮﺷﻲ ﺗﻴﺮ اﻳﺠﺎد ﻣﻲ ﻧﻤﺎﻳﺪ‪.‬‬ ‫‪ .4‬ﺑﺮاي ﻃﺮاﺣﻲ ﺳﺘﻮن ﻫﺎ ﮔﺰﻳﻨﻪ ”‪ “Reinforcement to be checked‬ﻣﻮرد ﻗﺒﻮل ﻧﺒﻮده و ﺑﺎﻳﺪ ﺑﺎ ﺗﻌﺮﻳﻒ ﻛﺎﻣﻞ‬ ‫ﻣﻘﺎﻃﻊ ﺳﺘﻮن ﻫﺎي ﻣﻮرد اﺳﺘﻔﺎده در ﻧﻘﺸﻪ ﻫﺎي ﺳﺎزه‪ ،‬ﺑﺎ اﺳﺘﻔﺎده از ﮔﺰﻳﻨﻪ ”‪“Reinforcement to be checked‬‬ ‫ﻣﻘﺪار ﻧﺴﺒﺖ ﺑﺎرﻫﺎي وارد ﺑﺮ ﺳﺘﻮن ﺑﻪ ﻇﺮﻓﻴﺖ ﻣﻘﻄﻊ ﺗﻮﺳﻂ ﻧﺮم اﻓﺰار ﻣﺤﺎﺳﺒﻪ ﺷﻮد‪.‬‬ ‫‪ .5‬ﺗﻮﺻﻴﻪ ﻣﻲ ﺷﻮد در آرﻣﺎﺗﻮرﻫﺎي ﻋﺮﺿﻲ ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺳﺨﺘﻲ ﺑﺎﻻي ﻣﻴﻠﮕﺮدﻫﺎي ‪ AIII‬ﻛﻪ ﻣﻮﺟﺐ اﻳﺠﺎد ﺗﺮك در‬ ‫ﻧﻮاﺣﻲ ﺧﻢ ﻣﻴﻠﮕﺮد ﻣﻲ ﺷﻮد‪ ،‬از آرﻣﺎﺗﻮر ‪ AII‬ﺑﺎ ﺗﻨﺶ ﺗﺴﻠﻴﻢ ‪ 3000 kg/cm2‬اﺳﺘﻔﺎده ﺷﻮد‪.‬‬ ‫‪ .6‬در ﺻﻮرت اﺳﺘﻔﺎده از ﺳﻴﺴﺘﻢ ﺑﺎرﺑﺮ ﺟﺎﻧﺒﻲ دوﮔﺎﻧﻪ‪ ،‬ﻛﻨﺘﺮل ﻗﺎب ﺧﻤﺸﻲ ﺗﻨﻬﺎ ﺑﺮاي ‪ %25‬ﺑﺮش ﭘﺎﻳﻪ در ﻳﻚ ﻓﺎﻳﻞ‬ ‫ﺟﺪاﮔﺎﻧﻪ اﻧﺠﺎم ﺷﻮد‪ .‬در اﻳﻦ ﺣﺎﻟﺖ ﺑﺎﻳﺪ دﻳﻮارﻫﺎي ﺑﺮﺷﻲ در ﻣﺪل ﺣﻔﻆ ﺷﺪه‪ ،‬ﻟﻴﻜﻦ ﺳﺨﺘﻲ آﻧﻬﺎ ﺑﺎ اﻋﻤﺎل ﺿﺮاﺋﺐ‬ ‫اﺻﻼح ﺳﺨﺘﻲ ﺑﺴﻴﺎر ﻛﻮﭼﻚ از ﻣﺎﺗﺮﻳﺲ ﺳﺨﺘﻲ ﺣﺬف ﺷﻮد‪ .‬ﻣﻤﻜﻦ اﺳﺖ در اﻳﻦ ﺣﺎﻟﺖ ﮔﺮه ﻫﺎي دﻳﻮار ﺑﺮﺷﻲ در‬ ‫ﺑﻴﻦ ﻃﺒﻘﺎت ﺑﻪ ﻋﻠﺖ ﺣﺬف ﺳﺨﺘﻲ دﻳﻮار ﺑﺮﺷﻲ‪ ،‬ﻣﻮﺟﺐ ﻧﺎﭘﺎﻳﺪاري ﺳﺎزه و ﺑﺮوز ‪ warning‬ﺷﻮﻧﺪ‪ .‬ﺟﻬﺖ ﺣﺬف اﻳﻦ‬ ‫اﺷﻜﺎل ﻣﻲ ﺗﻮان در ﻓﺎﻳﻞ ‪ %25‬از ﻣﺶ ﻛﺮدن دﻳﻮار ﺑﺮﺷﻲ ﺻﺮﻓﻨﻈﺮ ﻛﺮد ﺗﺎ ﮔﺮه ﻫﺎي ﻣﻴﺎن ﻃﺒﻘﺎت ﺣﺬف ﺷﻮﻧﺪ‪.‬‬ ‫‪ .7‬در ﺻﻮرت وﺟﻮد دﻳﻮار ﺑﺮﺷﻲ در ﺳﺎزه‪ ،‬درﺑﺎره ﻓﺮﺿﻴﺎت و روش ﻃﺮاﺣﻲ دﻳﻮار در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ﺗﻮﺿﻴﺢ‬ ‫داده ﺷﻮد‪ .‬ﻧﺤﻮه ﻃﺮاﺣﻲ دﻳﻮارﻫﺎ در ﻓﺎﻳﻞ ﺳﺎزه ﺑﺎﻳﺪ ﻛﺎﻣﻼ ﻣﺸﺨﺺ ﺑﺎﺷﺪ‪.‬‬ ‫‪ .8‬در ﺻﻮرت وﺟﻮد ﺑﺎزﺷﻮ در دﻳﻮارﻫﺎي ﺑﺮﺷﻲ‪ ،‬ﺑﺎﻳﺪ ﻣﺶ ﺑﻨﺪي دﻳﻮار ﺑﻪ ﻧﺤﻮي اﻧﺠﺎم ﮔﻴﺮد ﻛﻪ ﻣﻄﺎﺑﻖ ﺷﻜﻞ‪ ،‬ﺑﻪ ﻫﺮ‬ ‫ﻳﻚ از ﻣﺠﻤﻮﻋﻪ دﻳﻮارﻫﺎي ﻫﺮ ﻃﺮف ﺑﺎزﺷﻮ )و ﺳﺘﻮﻧﻬﺎي ﻣﺘﺼﻞ ﺑﻪ آﻧﻬﺎ( ﺷﻤﺎره ﭘﺎﻳﻪ )‪ (Pier Label‬ﺟﺪاﮔﺎﻧﻪ‬ ‫اﺧﺘﺼﺎص داده ﺷﻮد‪ .‬ﻗﺴﻤﺖ ﻫﺎﻳﻲ از ﺗﻴﺮﻫﺎ و دﻳﻮارﻫﺎ ﻛﻪ ﻣﺠﻤﻮﻋﻪ ﭘﺎﻳﻪ ﻫﺎي دو ﻃﺮف را ﺑﻪ ﻫﻢ وﺻﻞ ﻣﻴﻜﻨﻨﺪ‪ ،‬ﺑﺎﻳﺪ‬ ‫ﺑﻪ ﻋﻨﻮان ﺗﻴﺮ ﻫﻤﺒﻨﺪ )‪ (Spandrel beam‬ﺗﻌﺮﻳﻒ ﺷﺪه و آرﻣﺎﺗﻮر ﻃﻮﻟﻲ‪ ،‬ﻋﺮﺿﻲ و ﻗﻄﺮي ﻣﺤﺎﺳﺒﻪ ﺷﺪه ﺗﻮﺳﻂ ﻧﺮم‬ ‫اﻓﺰار ﺑﺮاي آن‪ ،‬در ﻧﻘﺸﻪ ﻫﺎي اﺟﺮاﻳﻲ در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮﻧﺪ‪ .‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﺑﺎﻳﺪ ﻓﻘﻂ ﻗﺴﻤﺘﻲ از ﺗﻴﺮ ﻛﻪ در ﻣﺤﺪوده‬ ‫ﺑﺎزﺷﻮ ﻗﺮار دارد ﺑﻪ ﻋﻨﻮان ﺗﻴﺮ ﻫﻤﺒﻨﺪ ﺗﻌﺮﻳﻒ ﺷﻮد‪ ،‬در ﻏﻴﺮ اﻳﻦ ﺻﻮرت‪ ،‬ﻧﺮم اﻓﺰار در ﺗﻌﻴﻴﻦ دﻫﺎﻧﻪ آزاد ﺗﻴﺮ ﻫﻤﺒﻨﺪ‬ ‫دﭼﺎر اﺷﻜﺎل ﺷﺪه و ﻧﺘﺎﻳﺞ ﻃﺮاﺣﻲ درﺳﺖ ﻧﺨﻮاﻫﺪ ﺑﻮد‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪32 :‬‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫دا ﻧ ﻮ‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫ﺻﻔﺤﻪ‪33 :‬‬

‫‪ -10‬ﻧﻜﺎت ﻣﻬﻢ در ﻓﺎﻳﻞ ﻣﺪل ﻛﺎﻣﭙﻴﻮﺗﺮي ﺳﺎزه ﻫﺎي ﻓﻠﺰي‬

‫‪ .1‬در ﻗﺴﻤﺖ ﺗﻌﻴﻴﻦ آﻳﻴﻦ ﻧﺎﻣﻪ ﻃﺮاﺣﻲ ﺳﺎزه ﻓﻠﺰي در ﻧﺮم اﻓﺰار‪ ،‬ﮔﺰﻳﻨﻪ ﻛﻨﺘﺮل ﺗﻐﻴﻴﺮ ﺷﻜﻞ ﺗﻴﺮﻫﺎ ﻓﻌﺎل ﺷﻮد‪.‬‬ ‫ﻧﺰدﻳﻜﺘﺮﻳﻦ آﻳﻴﻦ ﻧﺎﻣﻪ ﻃﺮاﺣﻲ ﺳﺎزه ﻫﺎي ﻓﻠﺰي ﺑﻪ ﻣﻘﺮرات ﻣﻠﻲ ﺳﺎﺧﺘﻤﺎن‪ AISC-ASD89 ،‬اﺳﺖ‪ ،‬ﻟﻴﻜﻦ ﺿﻮاﺑﻂ‬ ‫ﻃﺮح ﻟﺮزه اي )ﺑﺨﺶ ‪ 3-10‬ﻣﺒﺤﺚ دﻫﻢ( در ﻧﺮم اﻓﺰار ﻛﻨﺘﺮل ﻧﻤﻲ ﺷﻮد و ﺑﺎﻳﺪ ﺑﺎ ﺗﻐﻴﻴﺮاﺗﻲ ﻛﻪ ﻃﺮاح در ﺗﺮﻛﻴﺐ‬ ‫ﺑﺎرﻫﺎ و ﭘﺎراﻣﺘﺮﻫﺎي ﻃﺮاﺣﻲ اﻳﺠﺎد ﻣﻴﻜﻨﺪ ﻛﻨﺘﺮل ﮔﺮدد‪ .‬ﺑﺮﺧﻲ از ﺿﻮاﺑﻂ ﻃﺮح ﻟﺮزه اي ﻧﻴﺰ ﻛﻪ در ﻧﺮم اﻓﺰار ﻗﺎﺑﻞ‬ ‫ﻛﻨﺘﺮل ﻧﻴﺴﺖ ﺑﺎﻳﺪ در دﻓﺘﺮﭼﻪ ﻣﺤﺎﺳﺒﺎت ﺑﺮرﺳﻲ و ﻣﺤﺎﺳﺒﺎت ﻻزم اراﺋﻪ ﺷﻮد‪.‬‬ ‫‪ .2‬در ﻣﻮرد ﻣﻬﺎرﺑﻨﺪﻫﺎي ﺿﺮﺑﺪري‪ ،‬ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ ﺿﺮاﺋﺐ ﻻﻏﺮي در ﺟﻬﺖ ﻣﺤﻠﻲ ﻣﻨﺎﺳﺐ ﺑﻪ آﻧﻬﺎ اﻋﻤﺎل ﮔﺮدد‪.‬‬ ‫ﺿﺮﻳﺐ ﻻﻏﺮي ﺑﺮاي ﺧﻤﺶ در داﺧﻞ ﺻﻔﺤﻪ ﻗﺎب ﺑﺮاﺑﺮ ‪ 0/5‬و ﺑﺮاي ﺧﻤﺶ در ﺧﺎرج از ﺻﻔﺤﻪ ﻗﺎب ﺑﺮاﺑﺮ ‪0/7‬‬ ‫ﻣﻨﻈﻮر ﮔﺮدد‪ .‬در ﺿﻤﻦ ﺗﻮﺟﻪ ﺷﻮد ﻛﻪ در ﻣﻮرد ﻣﻬﺎرﺑﻨﺪﻳﻬﺎي ﺿﺮﺑﺪري‪ ،‬ﺑﻪ ﻋﻠﺖ ﺑﺮﺧﻮرد اﻋﻀﺎي ﻣﻬﺎرﺑﻨﺪي ﺑﺎ ﻫﻢ‪،‬‬ ‫ﻧﺮم اﻓﺰار ‪ ETABS2000‬ﺑﻪ ﻃﻮر ﺧﻮدﻛﺎر ﺿﺮﻳﺐ ﻃﻮل ﻣﻬﺎرﻧﺸﺪه ﻋﻀﻮ در ﺟﻬﺖ ﺧﻤﺶ داﺧﻞ ﺻﻔﺤﻪ‬ ‫)‪ (Unbraced Length Ratio‬را ﺑﺮاﺑﺮ ‪ 0/5‬ﻣﺤﺎﺳﺒﻪ ﻣﻴﻜﻨﺪ‪ ،‬ﺑﻨﺎﺑﺮاﻳﻦ در اﻳﻦ ﺣﺎﻟﺖ ﺑﺎﻳﺪ ﺿﺮﻳﺐ ﻻﻏﺮي )‪ (K‬در‬ ‫ﺟﻬﺖ ﺧﻤﺶ داﺧﻞ ﺻﻔﺤﻪ ﺑﺮاﺑﺮ واﺣﺪ ﺗﻌﺮﻳﻒ ﺷﻮد‪.‬‬ ‫‪ .3‬ﮔﺰﻳﻨﻪ در ﻧﻈﺮ ﮔﺮﻓﺘﻦ اﺛﺮات ‪ P-Δ‬در ﺳﺎزه ﻫﺎي ﻓﺎﻗﺪ ﻣﻬﺎر ﺟﺎﻧﺒﻲ ﻓﻌﺎل ﮔﺮدد‪.‬‬ ‫‪ .4‬در ﺳﺎزه ﻫﺎي ﻓﻠﺰي ﺑﺎ ﺷﻜﻞ ﭘﺬﻳﺮي ﻣﺘﻮﺳﻂ و وﻳﮋه‪ ،‬ﺑﺎﻳﺪ ﺳﺘﻮﻧﻬﺎي ﺳﺎزه ﺗﺤﺖ اﺛﺮ ﺗﺮﻛﻴﺒﺎت ﺑﺎر ﺑﺨﺶ ‪-3-10‬‬ ‫‪ 1-6‬ﻛﻨﺘﺮل ﺷﻮﻧﺪ‪ .‬از آﻧﺠﺎ ﻛﻪ ﺗﺤﺖ ﺗﺮﻛﻴﺐ ﺑﺎرﻫﺎي ﻣﻘﺎوﻣﺘﻲ‪ ،‬اﻓﺰاﻳﺶ ﺗﻨﺶ ﻣﺼﺎﻟﺢ ﻣﺠﺎز ﻧﻴﺴﺖ‪ ،‬ﻟﻄﻔﺎ ﺗﻮﺟﻪ ﺷﻮد‬ ‫ﻛﻪ در ﺗﺒﺪﻳﻞ اﻳﻦ ﺗﺮﻛﻴﺒﺎت ﺑﺎر ﻣﻘﺎوﻣﺘﻲ ﺑﻪ ﺣﺎﻟﺖ ﺗﻨﺸﻬﺎي ﻣﺠﺎز‪ ،‬ﺑﺎﻳﺪ ﺗﺮﻛﻴﺒﺎت ﺑﺎر در ﺿﺮﻳﺐ اﻓﺰاﻳﻨﺪه "‪"4/3‬‬ ‫ﺿﺮب ﺷﻮﻧﺪ ﺗﺎ اﺛﺮ اﻓﺰاﻳﺶ ﺗﻨﺸﻬﺎي ﻣﺠﺎز در ﻃﺮاﺣﻲ ﻛﺎﻣﭙﻴﻮﺗﺮي ﺧﻨﺜﻲ ﺷﻮد‪ .‬ﺑﺮاي ﺣﺬف اﺛﺮ ﻟﻨﮕﺮ ﺧﻤﺸﻲ در‬ ‫ﻃﺮاﺣﻲ ﻛﺎﻣﭙﻴﻮﺗﺮي‪) ،‬ﻛﻨﺘﺮل اﻳﻦ ﺗﺮﻛﻴﺒﺎت ﺑﺎر( ﻣﻲ ﺗﻮان در ﻓﺎﻳﻞ ﺟﺪاﮔﺎﻧﻪ اي ﻛﻪ ﺑﺮاي ﺑﺮرﺳﻲ اﻳﻦ ﺗﺮﻛﻴﺒﺎت ﺑﺎر‬ ‫اﻳﺠﺎد ﻣﻲ ﺷﻮد‪ ،‬ﺗﻨﺶ ﻣﺠﺎز ﺧﻤﺸﻲ ﺳﺘﻮﻧﻬﺎ را ﺑﻴﻨﻬﺎﻳﺖ ﺗﻌﺮﻳﻒ ﻛﺮد‪ .‬ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﻣﻮارد ﻓﻮق‪ ،‬ﺗﺮﻛﻴﺐ ﺑﺎرﻫﺎ ﭘﺲ از‬ ‫ﺗﺒﺪﻳﻞ ﺑﻪ ﺣﺎﻟﺖ ﺗﻨﺸﻬﺎي ﻣﺠﺎز‪ ،‬ﺑﻪ ﺷﻜﻞ زﻳﺮ ﺧﻮاﻫﺪ ﺑﻮد‪:‬‬ ‫اﻟﻒ( ﻓﺸﺎر ﻣﺤﻮري‪:‬‬

‫‪(4 / 3)( PD + 0.7 PL + Ωo PE ) / 1.7 ≤ Fa A‬‬ ‫‪→ 0.785PD + 0.549 PL + 0.785Ωo PE ≤ Fa A‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫دا ﻧ ﻮ‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫ﺻﻔﺤﻪ‪34 :‬‬

‫‪(4 / 3)(0.6)(0.85PD + Ωo PE ) ≤ Ft A‬‬

‫ب( ﻛﺸﺶ ﻣﺤﻮري‪:‬‬

‫‪→ 0.68PD + 0.8Ωo PE ≤ Ft A‬‬

‫ﻻزم ﺑﻪ ﺗﻮﺿﻴﺢ اﺳﺖ ﻛﻪ اﮔﺮ در ﺑﺎرﮔﺬاري ﻟﺮزه اي ﺳﺎزه ﺗﺮﻛﻴﺐ ﻧﻴﺮوي زﻟﺰﻟﻪ در دو ﺟﻬﺖ ﻻزم ﺑﺎﺷﺪ‪ ،‬در‬ ‫ﺗﺮﻛﻴﺐ ﺑﺎرﻫﺎي ﻓﻮق ﻧﻴﺰ ﺑﺎﻳﺪ اﻳﻦ ﻣﺴﺎﻟﻪ در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮد‪ .‬ﻫﻤﭽﻨﻴﻦ در ﺻﻮرت اﻧﺠﺎم ﺗﺤﻠﻴﻞ ﻃﻴﻔﻲ‪ ،‬ﺗﺮﻛﻴﺒﺎت‬ ‫ﺑﺎر ﻓﻮق ﺑﺎﻳﺪ ﺑﺮاي ﺣﺎﻟﺖ ﻃﻴﻔﻲ ﻣﺤﺎﺳﺒﻪ ﺷﻮﻧﺪ‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪35 :‬‬

‫‪ -11‬ﻧﻜﺎت ﻣﻬﻢ در ﻓﺎﻳﻞ ﻣﺪل ﻛﺎﻣﭙﻴﻮﺗﺮي ﺷﺎﻟﻮده‬

‫‪ .1‬ﺿﺮﻳﺐ ﻋﻜﺲ اﻟﻌﻤﻞ ﺑﺴﺘﺮ ﻃﺒﻖ ﻧﺘﺎﻳﺞ ﮔﺰارش ﻣﻜﺎﻧﻴﻚ ﺧﺎك در ﻓﺎﻳﻞ وارد ﺷﻮد‪.‬‬ ‫‪ .2‬ﻋﻼوه ﺑﺮ ﺗﺮﻛﻴﺐ ﺑﺎرﻫﺎي ﻃﺮاﺣﻲ ﻣﻘﺎﻃﻊ ﺑﺘﻨﻲ‪ ،‬ﺑﺎﻳﺪ ﺗﺮﻛﻴﺐ ﺑﺎرﻫﺎي ﺣﺎﻟﺖ ﺑﻬﺮه ﺑﺮداري ﻧﻴﺰ ﺑﺮاي ﻛﻨﺘﺮل ﺗﻨﺶ‬ ‫زﻳﺮ ﺷﺎﻟﻮده‪ ،‬ﺑﻪ ﻧﺮم اﻓﺰار ﻣﻌﺮﻓﻲ ﺷﻮﻧﺪ‪.‬‬ ‫‪ .3‬ﺟﻬﺖ در ﻧﻈﺮ ﮔﺮﻓﺘﻦ ﻧﻴﺮوﻫﺎي ﺑﺮﻛﻨﺶ‪ ،‬ﮔﺰﻳﻨﻪ ‪ Iterative for uplift‬ﺑﺎ ﺗﻌﺪاد ﻛﺎﻓﻲ ﺗﻜﺮار )‪ (Iteration‬ﻓﻌﺎل‬ ‫ﺷﻮد‪ .‬ﺣﺪاﻛﺜﺮ ﻋﺮض ﻣﺠﺎز ﺑﺮاي ﻧﺎﺣﻴﻪ ﺗﻨﺶ ﺻﻔﺮ در زﻳﺮ ﺷﺎﻟﻮده‪ ،‬ﻃﺒﻖ ﺑﻨﺪ ‪ 3-2-4-17-9‬ﻳﻚ ﭼﻬﺎرم ﺑ‪‬ﻌﺪ‬ ‫ﺷﺎﻟﻮده اﺳﺖ ﻛﻪ ﺑﺎﻳﺪ در ﺗﺮﻛﻴﺒﺎت ﺑﺎر ﺣﺎﻟﺖ ﺑﻬﺮه ﺑﺮداري ﻛﻨﺘﺮل ﺷﻮد‪.‬‬ ‫‪ .4‬در ﺳﺎزه ﻫﺎي داراي دﻳﻮار ﺑﺮﺷﻲ‪ ،‬ﺑﺮاي اﻧﺘﻘﺎل ﺻﺤﻴﺢ و واﻗﻌﻲ ﻧﻴﺮوﻫﺎي دﻳﻮار ﺑﻪ ﺷﺎﻟﻮده ﺑﺎﻳﺪ ﺗﻘﺴﻴﻢ ﺑﻨﺪي‬ ‫)‪ (mesh‬دﻳﻮارﻫﺎ ﺑﻪ ﺣﺪ ﻛﺎﻓﻲ رﻳﺰ ﺷﻮد‪).‬ﺗﺎ ﺣﺪود ‪ 0/5‬ﻣﺘﺮ ﺗﻮﺻﻴﻪ ﻣﻲ ﺷﻮد(‬ ‫‪ .5‬در ﺳﺎﺧﺘﻤﺎﻧﻬﺎي داراي اﺳﺘﺨﺮ‪ ،‬در ﺻﻮرﺗﻲ ﻛﻪ ﺷﺎﻟﻮده اﺳﺘﺨﺮ و ﺳﺎزه ﺑﻪ ﻃﻮر ﻳﻜﭙﺎرﭼﻪ در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﻮﻧﺪ‪ ،‬ﺑﺎﻳﺪ‬ ‫ﻣﺪل ﺳﺎزي ﺷﺎﻟﻮده ﻧﻴﺰ ﺑﺎ در ﻧﻈﺮ ﮔﺮﻓﺘﻦ اﻳﻦ ﻣﺴﺎﻟﻪ اﻧﺠﺎم ﺷﻮد‪.‬‬ ‫‪ .6‬در ﻣﻮرد ﺳﺎزه ﻫﺎي ﻓﻠﺰي‪ ،‬اﻧﺪازه ﺳﻄﺢ اﺛﺮ ﺑﺎر ﺑﺮاي ﻫﺮ ﺳﺘﻮن ﺑﺮ روي ﺷﺎﻟﻮده )‪ (Size of Load‬ﺑﺮاﺑﺮ ‪ %90‬اﺑﻌﺎد‬ ‫ورق ﻛﻒ ﺳﺘﻮن ﺗﻌﻴﻴﻦ ﺷﻮد ﺗﺎ ﻣﺤﺎﺳﺒﺎت ﺑﺮش ﭘﺎﻧﭻ ﺑﺮ ﻣﺒﻨﺎي آن اﻧﺠﺎم ﮔﻴﺮد‪.‬‬ ‫‪ .7‬ﻧﻮارﻫﺎي ﻃﺮاﺣﻲ ﺑﺎﻳﺪ در ﻫﺮ دو ﺟﻬﺖ ﺑﻪ ﻧﺤﻮي ﺗﻌﺮﻳﻒ ﺷﻮﻧﺪ ﻛﻪ ﻛﻞ ﺳﻄﺢ ﺷﺎﻟﻮده را ﭘﻮﺷﺶ دﻫﻨﺪ‪.‬‬ ‫‪ .8‬در ﺻﻮرت اﺳﺘﻔﺎده از ﺷﻤﻊ در ﻓﻮﻧﺪاﺳﻴﻮن‪ ،‬اﮔﺮ ﻋﻤﻖ ﺷﻤﻊ ﻛﻢ ﺑﺎﺷﺪ )ﻛﻤﺘﺮ از ﺣﺪود ‪ 15‬ﻣﺘﺮ( و ﻳﺎ ﺑﻪ ﻻﻳﻪ ﻣﻘﺎوم‬ ‫ﺑﺴﺘﺮ ﺳﻨﮕﻲ ﻧﺮﺳﺪ‪ ،‬ﺑﺎﻳﺪ از ﻣﺪل ﺳﺎزي آن در ﻓﺎﻳﻞ ﻓﻮﻧﺪاﺳﻴﻮن ﺻﺮﻓﻨﻈﺮ ﺷﻮد‪ .‬در ﺻﻮرﺗﻲ ﻛﻪ ﺷﻤﻊ ﻋﻤﻴﻖ ﺑﺎﺷﺪ‪ ،‬ﺑﺎ‬ ‫ﻣﺤﺎﺳﺒﻪ ﺳﺨﺘﻲ ﺑﺮ ﻣﺒﻨﺎي ﮔﺰارش ﻣﻜﺎﻧﻴﻚ ﺧﺎك‪ ،‬در ﻣﺪل ﻓﻮﻧﺪاﺳﻴﻮن در ﻧﻈﺮ ﮔﺮﻓﺘﻪ ﺷﺪه و ﭘﺲ از ﺗﺤﻠﻴﻞ ﺑﺎﻳﺪ‬ ‫ﺑﺮاي ﻧﻴﺮوﻫﺎي ﻓﺸﺎري و ﻛﺸﺸﻲ وارد ﺑﺮآن ﻛﻨﺘﺮل و ﻃﺮاﺣﻲ اﺑﻌﺎدي و ﻣﺤﺎﺳﺒﻪ آرﻣﺎﺗﻮرﮔﺬاري اﻧﺠﺎم ﮔﻴﺮد‪.‬‬ ‫ﻛﻠﻴﻪ ﻣﻮارد ﺑﺎﻳﺪ ﺑﺎ ﺗﻮﺟﻪ ﺑﻪ ﺗﻮﺻﻴﻪ ﻫﺎي ﮔﺰارش ﻣﻜﺎﻧﻴﻚ ﺧﺎك اﻧﺠﺎم ﺷﻮد و ﻣﺤﺎﺳﺒﺎت ﻻزم ﺑﺎﻳﺪ در دﻓﺘﺮﭼﻪ‬ ‫ﻣﺤﺎﺳﺒﺎت ذﻛﺮ ﺷﻮد‪.‬‬ ‫‪ .9‬از آﻧﺠﺎ ﻛﻪ در ﻧﺮم اﻓﺰار ‪ SAFE‬ﻣﺤﺎﺳﺒﻪ ﺗﻨﺸﻬﺎي زﻳﺮ ﺷﺎﻟﻮده ﺑﺪون در ﻧﻈﺮ ﮔﺮﻓﺘﻦ اﺛﺮ ﺿﺨﺎﻣﺖ ﺷﺎﻟﻮده در‬ ‫اﻓﺰاﻳﺶ ﻟﻨﮕﺮ ﺧﻤﺸﻲ ﭘﺎي ﺳﺘﻮﻧﻬﺎ )ﻧﺎﺷﻲ از اﻧﺘﻘﺎل ﻧﻴﺮوﻫﺎ ﺑﻪ زﻳﺮ ﺷﺎﻟﻮده( اﻧﺠﺎم ﻣﻴﺸﻮد‪ ،‬ﻻزم اﺳﺖ ﻗﺒﻞ از ‪Export‬‬

‫ﻛﺮدن ﻧﻴﺮوي ﭘﺎي ﺳﺘﻮﻧﻬﺎ از ﻧﺮم اﻓﺰار ‪ Etabs‬ﻳﻚ ﻃﺒﻘﻪ ﻣﺠﺎزي در روي ﺗﺮاز ‪ Base‬ﺑﺎ ارﺗﻔﺎع ﻣﻌﺎدل ﺿﺨﺎﻣﺖ‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬

‫ﺳﺎزﻣﺎن ﻧﻈﺎم ﻣﻬﻨﺪﺳﻲ اﺳﺘﺎن ﺗﻬﺮان ‪ -‬دﻓﺘﺮ ﻛﻨﺘﺮل ﺳﺎﺧﺘﻤﺎن‬

‫د ﺮ را ﻤﺎی ﮑﺎت ﺣﺎ ا ﺖ ﺤﺎ ﺒﺎت و ﻪ ی ﺳﺎزه‬

‫ﮔﺮدآوري و ﺗﻨﻈﻴﻢ‪:‬‬

‫ﻦ‬

‫ﺷﻤﺎره ﺑﺎزﻧﮕﺮي ‪3 :‬‬ ‫زﻣﺎن ﺑﺎزﻧﮕﺮي ‪ :‬دي ‪87‬‬

‫ﺷﻤﺎره ﻣﺪرك‪CTL-STR-CMSTK-001-R3 :‬‬

‫زﻣﺎن اوﻟﻴﻦ ﺑﺎزﻧﮕﺮي‪ :‬آﺑﺎن ‪87‬‬

‫دا ﻧ ﻮ‬ ‫ﺻﻔﺤﻪ‪36 :‬‬

‫ﺷﺎﻟﻮده ﺗﻌﺮﻳﻒ ﺷﻮد‪ .‬در اﻳﻦ ﻃﺒﻘﻪ ﺑﺎﻳﺪ ﻓﻘﻂ ﺳﺘﻮﻧﻬﺎ و دﻳﻮارﻫﺎ ﺑﺎ ﻣﺸﺨﺼﺎت ﺗﺮاز ﻓﻮﻗﺎﻧﻲ ﻣﺪل ﺷﻮﻧﺪ و ﺑﺎ اﺳﺘﻔﺎده‬ ‫از ﺗﻌﺮﻳﻒ ﻣﺼﺎﻟﺤﻲ ﺑﺎ وزن ﺣﺠﻤﻲ و ﺟﺮم ﺣﺠﻤﻲ ﺻﻔﺮ و ﺿﺮﻳﺐ ارﺗﺠﺎﻋﻲ ﺑﺴﻴﺎر ﺑﺰرگ )ﻳﺎ ﺿﺮاﺋﺐ اﺻﻼح ﺟﺮم‪،‬‬ ‫وزن و ﺳﺨﺘﻲ(‪ ،‬وزن و ﺟﺮم ﻛﻠﻴﻪ ﻋﻨﺎﺻﺮ اﻳﻦ ﻃﺒﻘﻪ ﺻﻔﺮ ﺷﻮد و ﺳﺨﺘﻲ ﻃﺒﻘﻪ ﺗﺎ ﺣﺪ اﻣﻜﺎن ﺑﺰرگ )ﺑﻴﻨﻬﺎﻳﺖ( ﺷﻮد‪.‬‬ ‫ﻫﻤﭽﻨﻴﻦ ﺑﺮاي ﺗﻌﺮﻳﻒ ﻧﻴﺮوﻫﺎي زﻟﺰﻟﻪ‪ ،‬ﺗﺮاز ﺷﺮوع ﺗﻮزﻳﻊ ﻧﻴﺮوي زﻟﺰﻟﻪ روي اﻳﻦ ﻃﺒﻘﻪ ﻣﺠﺎزي ﺗﻌﺮﻳﻒ ﺷﻮد‪ .‬ﺑﺎ در‬ ‫ﻧﻈﺮ ﮔﺮﻓﺘﻦ ﻣﻮارد ﻓﻮق‪ ،‬ﭘﺲ از ﺗﺤﻠﻴﻞ ﻛﺎﻣﭙﻴﻮﺗﺮي‪ ،‬ﻋﻜﺲ اﻟﻌﻤﻞ ﻫﺎي ﺗﻜﻴﻪ ﮔﺎﻫﻲ ‪ Export‬ﺷﻮﻧﺪ‪.‬‬

‫"اﮔﺮ ﻛﺎري ارزش اﻧﺠﺎم داﺷﺘﻪ ﺑﺎﺷﺪ‪ ،‬ارزش ﻫﻢ دارد ﺑﻪ ﺑﻬﺘﺮﻳﻦ ﻧﺤﻮ اﻧﺠﺎم ﺷﻮد"‬