LEMBAR PENILAIAN DOKUMEN TEKNIS STRUKTUR ATAS KE I 1.

DATA BANGUNAN a Nama Proyek b Jenis Bangunan c Lokasi Bangunan d Jumlah Lantai e Perencana Struktur SIPTB No

f g 2.

Penilaian Struktur Atas Tanggal

: : : : : : : :

MENARA ASTRA DEVELOPMENT Beton Bertulang Jl. Jend. Sudirman No. 5 Jakarta Pusat 50 Lantai +5 lantai podium+ 6 Basement Ir. Suyandra Gunawan 0775/P/GA/DPPB/I-2012 Pemeriksaan ke 1 06 November 2013

HASIL PEMERIKSAAN Jenis Evaluasi I. Pembebanan Kami mohon penjelasan berapa besar beban untuk Helipad

II. Pemodelan dan Analisis Struktur: 1. Perencanaan ANNEX sebaiknya menggunakan SRPMK sehingga mempunyai daktilitas maksimum 2. Partisipasi Massa Tower dan Annex mohon dicantumkan secara lengkap termasuk rasio (%) untuk ragam torsi. Ratio Partisipasi Massa dari Tabel ETABS yang mencapai minimal 90% mohon dilampirkan . Mode 1 dan 2 harus dominan arah lateral tidak boleh dominasi dalam arah torsional. 3. Pada Tabel Bab 2.8.5.2 disebutkan = 0,17 seharusnya = 0,18 sebab Jakarta termasuk Wilayah 3. Untuk gedung Annex maksimum T = 0,18 x 5 =0,9 detik padahal T1= 1,05 detik > 0,9 detik sehingga tidak memenuhi syarat. Dengan demikian dimensi struktur harus di revisi. 4. Untuk gedung tinggi > 200 m maka harus diperhitungkan C min (C=0,01) dalam perhitungan Vb static ragam 1 (V1) dalam memperhitungkan factor skala, sesuai dengan standar UBC 1997 (kompatibilitas dengan SNI 17262002). Kami mohon di check kembali V1 dengan C minimum. Jakarta, 06 November 2013

Bambang Budiono