Sounds of Equipments This spreadsheet provides estimations and/or default values of Sound Power and/or Sound Pressure Level for common industrial equipments (fans, compressors, pumps, turbines, etc). Sound Power Level (SWL) is defined as sound radiated from an equipment/a source which depends only on its operating parameters such as RPM, kW, etc. It does not depend on distance. While Sound Pressure Level (SPL) is defined as sound heard by a receptor from an equipment/a source at certain distance. So, SPL is correlated with SWL. At certain conditions, SPL may become noise (unwanted sound). This spreadsheet contains four sheets, started by this sheet 'Introduction' and sequentially followed by sheets 'Main Sheet', 'Data1', and at the end 'Data2'. 'Main Sheet' is where estimations of SWL and SPL are done. Default values are also provided in this sheet. Sheet 'Data 1' is for data required for estimating SWL of fans. While sheet 'Data 2' is data required for estimating SWL of casing of diesel and/or gas-driven engine and transformers. Need to remember!!!!!!! All estimated and default SPLs (not SWLs) are for uncontrolled sounds. SPLs estimated in this spreadsheet are only depended on distance (1 meter). They do not take into account control factors like barriers and other control efforts. Reference: Bies, David A. & Hansen, Colin H. 2003. “Engineering Noise Control: Theory and Practice”. 3rd Edition. Taylor & Francis Prepared by: Muhamad Nizar
Equipment
Input Data
Calculated SWL
Calculated SPL at 1 m
(dB)
(dB)
Default Value (dB) SWL
SPL at 1 m
Fans See Sheet 'Data1'
Cf Q (m3/s)
See Sheet 'Data1'
33 0.237
P (Pa)
125
E (%)
90
BFI
60
3
Compressor Air Compressor (Up to 1.5 kW)
92
Air Compressor (2-6 kW)
95
Air Compressor (7-75 kW)
98
Rotary
kW
45
107
Centrifugal (casing noise excluding air inlet noise)
kW
45
96
Centrifugal (unmuffled air inlet noise excluding casing noise)
kW
45
97
kW
70
115
kW
80
115
3000-3600 rpm (Under 75 kW)
kW
70
90
3000-3600 rpm (Above 75 kW)
kW
80
92
1600-1800 rpm (Under 75 kW)
kW
70
93
1600-1800 rpm (Above 75 kW)
kW
80
95
1000-1500 rpm (Under 75 kW)
kW
70
88
1000-1500 rpm (Above 75 kW)
kW
80
90
450-900 rpm (Under 75 kW)
kW
70
86
450-900 rpm (Above 75 kW)
kW
80
88
General purpose boiler
kW
70
102
Large power plant boiler
MW
110
115
Casing
MW
110
130
Inlet
MW
110
158
Exhaust
MW
110
153
Cooling Towers Propeller Type cooling tower (Fan power up to 75 kW) Substract 8 dB if the fan is operated 1/2 its rated speed Propeller Type cooling tower (Fan power greater than 75 kW) Substract 8 dB if the fan is operated 1/2 its rated speed Pumps
Boilers
Gas Turbines
Overall noise
159
Steam Turbines Overall noise
kW
12500
109
Equipment
Calculated SWL
Input Data
(dB)
Calculated SPL at 1 m (dB)
Default Value (dB) SPL at 1 SWL m
Diesel and/or Gas-Driven Engines Exhaust
kW (0 for engine with no turbo-charger, 6 for engine with turbo charger) Length of exhaust pipe (m)
Casing
110 0
K 10 Lex kW
110
See Sheet 'Data2'
A
0
See Sheet 'Data2'
B
0
See Sheet 'Data2'
C
0
See Sheet 'Data2'
D
0
Air inlet
kW Length of inlet ducting (m)
132
L
110
113
100
10
Overall noise
132
Furnace Burner noise Air flow
U
10
m
10
U
10
m
10
105 114
Overall noise
103 107
Electric Motors Under 40 kW
kW RPM
40 kW < W < 300 kW
kW RPM
30
72
100 50
75
100
Above 300 kW Generators MW
10
RPM
100
107
Transformers See Sheet 'Data2'
Nr
See Sheet 'Data2'
S (kVA)
50
70
100
Gears kW RPM
10
88
100
Crushers Primary Crusher
121
Secondary Crusher
129
Tertiary Crusher
127
Conveyors Open conveyor (per meter)
82
Enclosed conveyor (per meter)
71