REM -1 Automatic Wrist Blood Pressure Monitor M ODEL
Fully automatic inflation and deflation Fuzzy logic Large display, easy to read Displays average of last 3 readings 40 sets memory Compact and easy to use at home, work or during travel. Battery low symbol to alert users to replace batteries
created by joko sutantiyo
[email protected] www.nautiza.com
The Omron REM-1 automatic wrist blood pressure monitor uses the oscillometric method of blood pressaure measurement. The monitor detects your blood movement through your brachial artery and converts the movements into a digital reading. Simply press the START/STOP button and the cuff will start to inflate automatically. After the unit has detected your blood pressure and pulse rate, the cuff automatically deflates and your blood pressure and pulse rate are displayed.
Average function Omron REM-1 displays the average of last 3 readings.
Correct Measurement Posture
Simple steps for accurate measurement 1. Attach cuff snugly on your left wrist.
Sit comfortably with your back straight, hold your arm across your chest and relax.
2. Place your left arm across the chest, and align the cuff at the same level as your heart. 3. Sit on a chair with your back straight. 4. Take 5 to 6 deep breaths and then relax. 5. Start measurement. Support your left elbow with your right hand to keep arm in position.
Position your arm so that the unit is at the same level as your heart (height of nipple).
6. Remain still and do not talk during the measurement. 7. Do not take a measurement after bathing, alcohol or exercise.
WHO Blood Pressure Classification The World Health Organization (WHO)/ International Society of Hypertention (ISH) developed the following Blood Pressure Classification, to be used as a general guidline only. Systolic (mmHg)
Diastolic (mmHg)
Optimal
less than 120
less than 80
Normal
120 to 129
80 to 84
High-Normal
130 to 139
85 to 89
Grade 1 hypertension (mild)
140 to 159
90 to 99
Grade 2 hypertension (moderate)
160 to 179
100 to 109
more than 180
more than 110
Grade 3 hypertension (severe)
There is no universally accepted definition of hypotension (low blood pressure), but a systolic pressure below 99 mmHg is usually regarded as hypotension.
SPECIFICATIONS Display Measurement Range
Digital Display Pressure: 0 to 299 mmHg, Pulse : 40 to 180 beats/min
Accuracy/Calibration Power Source Battery Life Weight of Main Unit External Dimensions Measurable Circumference of Wrist Contents
Pressure: Within +3mmHg, Pulse rate: Within +5% of reading Two 1.5V AAA alkaline batteries Approx. 300 measurements when using alkaline batteries at the room temperature of 23 C and by using two times a day and inflating to 170 mmHg Approx. 120g (not including batteries) 72mm (w) x 56mm (h) x 44mm (d) (not including the wrist cuff) Approx. 13.5 cm to 21.5 cm Storage case, 2 AAA Alkaline batteries,Instruction manual
NOTE: These specifications are subject to change without notice.