Pressure Sensor - 2ZPS004704324 2.50"

0-5“ H2O Pressure Range - 5 VDC Operation

3.92 VDC

3.95-4.05 VDC

4.08 VDC

Null Offset

0.17 VDC

0.2-0.3 VDC

0.33 VDC

3.59 VDC

3.65-3.85 VDC

Span*

±0.03 % Span

±0.05 % Span

±1.0 % Span ±1.0 % Span

±1.5 % Span ±1.5 % Span

Supply Voltage (Vs)

5.0 VDC

Common Mode Pressure

0.15" DIA.

UP

1.29" 0.15"

±0.5 % Span 4.75 VDC

12.0" APPROX.

OUT

Hystereisis And Repeatability Temperature Error Null +10° To 40°C Span +10° To 40°C Stability (1 Year)

IN

±0.3 % Span

GND

Non-Linearity

3.91 VDC ±0.5 % Span

OUT (Black)

Full Scale Output (Positive Pressure)

2.20"

Maximum

GND (Green)

Typical

IN (Red)

Minimum

8.0 VDC

2ZPS004704324 S.P. Sensor

2.94"

15 PSI

Pressure Overload Positive Pressure (Hi Side) Negative Pressure (Lo Side)

25“ H2O 15“ H2O

Burst Pressure Positive Pressure (Hi Side) Negative Pressure (Lo Side)

50“ H2O 25“ H2O

0.60" (-)LO

0.200" (3/16" Tubing Conn.) 0.125" (1/8" Tubing Conn.)

Top View

*Span Is The Algebraic Difference Between End Points (Null Offset And Full Scale Output)

Warning!

1.95"

The plastic housing on the sensor is electrically conductive. Avoid contact with any electrical components. It is acceptable to mount the sensor on grounded sheet metal such as ductwork, electrical panels, etc.

0.55"

1.00" 0.35"

Warning! Use extreme care when mounting the sensor to avoid damage to the plastic housing. Do not overtighten the mounting screws! Do not use mounting screws which are too large for the holes!

Side View

General Notes 1.)Caution:The 2ZPS004704324 Pressure Sensor Should Be Mounted In A Vertical Position As Shown With Arrow Pointing Up. ( Tubing Connections Pointing Down). If This Mounting Position Is Not Possible In Your Application, It May Be Mounted In A Horizontal Position. When Mounted In A Horizontal Position Accuracy Will Be Affected By Approximately 2% Full Scale Null Shift Due To Diaphragm Gravity Effect Error.

2.)All Wiring To Be In Accordance With Local And National Electrical Codes And Specifications.

Duct Static Pressure Sensor Applications Mounting Information When The Sensor Is Used As A Duct Static Pressure Sensor It May Be Mounted To The Ductwork Near The Static Pressure Pickup Tube. If The Sensor Is Mounted In This Manner, Away From The Controller, The Modular Plug Must Be Cut Off And 3-conductor 24 Gauge Minimum Wire Must Be Butt Spliced To The Sensor Leads. The Controller Has A Terminal Block Which Is Paralleled With The Modular Jack To Allow Wiring Connections. Total Wire Length Should Not Exceed 100Ft. If Desired The Sensor May Also Be Located Near The Controller, With The Modular Plug On The Sensor Directly Connected To The Mating Controller Jack. When This Method Is Used Tubing Must Be Run From The Sensor To The Staic Pressure Pickup Tube. Tubing Should Not Exceed 250 Ft. And Must Be Continuous Without Any Splices.

JOB NAME

FILENAME 036-22301-001-A-0602.CDR

DATE: PAGE

1 of 1

06/28/02

DRAWN BY:

B. CREWS

DESCRIPTION:

2ZPS004704324 Pressure Sensor Form: 036-22301-001 Rev. A (0602) Supersedes: Nothing

Related Documents