No. de Usuarios = 92 KVA Usuarios = 0,76 70.18

No. de Usuarios = 151 KVA Usuarios = 0,69 KVA Total = 104,91

Luminarias 70W = 15 Watios = 1050 1.1053

106.0152631579

No. de Usuarios = 92 KVA Usuarios = 0,76 70.18

VEREDA SAN JUAN CALCULO DE REGULACIÓN EN BAJA TENSIÓN Y PERDIDAS

Tramo

Conductor Aluminio, quadruplex trenzado

0-6 6-7 7-8 8-9

2/0 2/0 2/0 2/0

(m) 30 30 30 30

0-1 1-4 4-5 1-2 2-3

2/0 2/0 2/0 2/0 2/0

2.2 34 32.8 27.8 30

Longitud Usuarios

KVA

Momento

FC

Regulación Regulación

18 14 8 3

Demanda 19.06 15.41 9.42 3.76

KVA *L 571.8 462.3 282.6 112.8

1 1 1 1

Parcial 0.71 0.58 0.35 0.14

31 18 10 10 5

29.72 19.06 11.49 11.49 6.12

65.384 648.04 376.872 319.422 183.6

1 1 1 1 1

0.08 0.81 0.47 0.40 0.23

10

TRANSFORMADOR: CAPACIDAD: KVA USUARIOS: TIPO: L. MEDIA: L. BAJA:

3 45 KVA 45.39 53 TRIFASICO 218 METROS 308,8 METROS

3 2/0 5 2

34

3 27.8

Total 0.71 1.29 1.65 1.79

Corregido 206.51 205.31 204.58 204.28

(KW) 0.13 0.09 0.03 0.01

ACU. (KW) 0.2610 0.1272 0.0386 0.0053

0.08 0.89 1.36 0.48 0.71

207.83 206.14 205.16 207.00 206.52

0.02 0.15 0.05 0.04 0.01

0.2884 0.2648 0.1126 0.0587 0.0138

4

2/0

2/0

Perdidas

32.8

8

30

Perdidas

5

2/0

5

Voltaje

1

4

2 2/0 2.2

2/0 0

30

5

6 2/0

6

30

2/0 7

30

2/0 8

30

3

VEREDA SAN JUAN CALCULO DE REGULACIÓN EN BAJA TENSIÓN Y PERDIDAS Tramo

Conductor

Longitud Usuarios KVA (m) Demanda 27 16 17.26 25.2 11 12.5 30.5 7 8.34

0-3 3-4 4-5

2/0 2/0 2/0

0-10 10-11 11-12 12-13 13-14

2/0 2/0 2/0 2/0 2/0

30 25.3 21.6 35.6 37

38 32 29 17 6

0-6 6-7 7-8 8-9 6-1 1-2

2/0 2/0 2/0 2/0 2/0 2/0

18 24.3 24.4 35 31 30.5

34 18 15 11 8 3

Momento KVA *L 466.02 315 254.37

FC

34.94 30.45 28.17 18.17 7.25

1048.2 770.385 608.472 646.852 268.25

1 1 1 1 1

1.31 0.96 0.76 0.81 0.34

1.31 2.27 3.03 3.84 4.18

31.99 19.06 16.34 12.5 9.42 3.78

575.82 463.158 398.696 437.5 292.02 115.29

1 1 1 1 1 1

0.72 0.58 0.50 0.55 0.37 0.14

0.72 1.30 1.80 2.34 1.08 1.23

1 1 1

Regulación Regulación Voltaje Parcial Total Corregido 0.58 0.58 206.79 0.39 0.98 205.97 0.32 1.29 205.31

Perdidas (KW) 0.10 0.05 0.03

Perdidas ACU. (KW) 0.1474 0.0752 0.0265

205.27 203.27 201.69 200.01 199.31

0.46 0.30 0.22 0.15 0.03

1.1530 0.6977 0.4003 0.1796 0.0256

206.50 205.30 204.26 203.12 205.74 205.44

0.23 0.11 0.08 0.07 0.03 0.01

0.5267 0.3004 0.1907 0.1089 0.0395 0.0054

11

TRANSFORMADOR: CAPACIDAD: KVA

2 75 KVA 69.52

2/0 4 2/0

9 35 8 24,4

2/0

USUARIOS: TIPO:

91 TRIFASICO

L. MEDIA: L. BAJA:

124,4 METROS 396,3 METROS

24,4

3

3

5 2

2/0 30,5

8 1

7 2/0 24,3

2/0 31

6 2/0

18 0 2/0

3

27

3

30

6 2/0

5

2/0

25,2

10 25,30

3 2/0

11 21,60

12

12

2/0 35,6

11 13

2/0 37

VEREDA SAN JUAN CALCULO DE REGULACIÓN EN BAJA TENSIÓN Y PERDIDAS Tramo

Conductor

1-0 0-2 2-3

2/0 2/0 2/0

1-9 9-10 10-11 13-14 9-15

2/0 2/0 2/0 2/0 2/0

Longitud Usuarios KVA (m) Demanda 25.3 15 16.34 26.3 10 11.49 25.4 7 8.34 17.8 27.8 37.1 24.4 37

55 33 26 7 16

46.78 31.24 25.8 8.34 17.26

Momento KVA *L 413.402 302.187 211.836

FC

832.684 868.472 957.18 203.496 638.62

1 1 1 1 1

1 1 1

Regulación Regulación Voltaje Parcial Total Corregido 0.52 0.52 206.93 0.38 0.89 206.14 0.26 1.16 205.59 1.04 1.09 1.20 0.25 0.80

1.04 2.13 3.32 3.58 1.84

205.83 203.58 201.09 200.56 204.17

4

2/0

Perdidas (KW) 0.08 0.04 0.02

Perdidas ACU. (KW) 0.1254 0.0647 0.0219

0.48 0.34 0.32 0.02 0.14

1.3377 0.8561 0.5131 0.1932 0.1711

6

15-16

2/0

37

7

8.34

308.58

1

0.39

2.23

203.37

0.03

0.0326

1-17

2/0

30

7

8.34

250.2

1

0.31

0.31

207.35

0.03

0.0254

1-4 4-5 5-6

2/0 2/0 2/0

23 15 28.6

20 18 14

20.81 19.06 15.41

478.63 285.9 440.726

1 1 1

0.60 0.36 0.55

0.60 0.96 1.51

206.76 206.01 204.87

0.12 0.07 0.08

0.1893 0.1520 0.0848

14

6 28,6

2/0

TRANSFORMADOR: CAPACIDAD: KVA USUARIOS: TIPO:

1 75 KVA 74.36 99 TRIFASICO

L. MEDIA: L. BAJA:

102 METROS 436,4 METROS

5

4

2/0 15

2 4

2/0 7

30

7

16

37

15 9

2/0

1 2/0

2/0

5

2

2/0 17

23

35,3

2/0 0

26.3

17,8

2/0 37

9 2/0

6 27,8 12 10

7

2/0 37,1

2/0 11

39

13 24,4 14

VEREDA SAN JUAN CALCULO DE REGULACIÓN EN BAJA TENSIÓN Y PERDIDAS

Tramo

Conductor

Longitud Usuarios KVA (m) Demanda 31 16 17.26 31 9 10.47 35 2 2.56

Momento KVA *L 535.06 324.57 89.6

FC

0-9 9-10 10-11

2/0 2/0 2/0

0-12

2/0

32

10

11.49

367.68

1

0.46

0.46

0-4 4-5 5-6 6-7 6-8 5-13

2/0 2/0 2/0 2/0 2/0 2/0

31.5 27 31 29 35 35

41 33 21 9 4 4

37.1 31.24 21.66 10.47 4.97 4.97

1168.65 843.48 671.46 303.63 173.95 173.95

1 1 1 1 1 1

1.46 1.05 0.84 0.38 0.22 0.22

0-1 1-2 2-14

2/0 2/0 2/0

60 31.5 30

23 17 8

23.85 18.17 9.42

1431 572.355 282.6

1 1 1

1.79 0.72 0.35

1 1 1

Regulación Regulación Voltaje Parcial Total Corregido 0.67 0.67 206.61 0.41 1.07 205.76 0.11 1.19 205.53

Perdidas (KW) 0.11 0.04 0.00

Perdidas ACU. (KW) 0.1554 0.0449 0.0028

207.04

0.05

0.0516

1.46 2.52 3.35 3.73 3.57 2.73

204.96 202.77 201.02 200.23 200.57 202.32

0.54 0.34 0.19 0.04 0.01 0.01

1.1288 0.5881 0.2524 0.0639 0.0223 0.0111

1.79 2.50 2.86

204.28 202.79 202.06

0.43 0.13 0.03

0.5609 0.1666 0.0342

14

TRANSFORMADOR: CAPACIDAD: KVA USUARIOS: TIPO:

4 75 KVA 73.76 98 TRIFASICO

L. MEDIA: L. BAJA:

68 METROS 439,30 METROS

2

8 30 9 31.5

1

9 7

8

29

6

8

31

35

5

35

13

8 4

27

4

6 30

8 30 7 7 2 31.5 31 31 35 0 10 9 11 4 32

8

12

10

30 2

9 31.5

1

9 7

8

29

6

8

31

35

5

35

13

8 4

27

4

6 30

8 30 7 7 2 31.5 31 31 35 0 10 9 11 4 32

8

12

10

cuadruplero asumido fp

0.5226 0.95

ÓN Y PERDIDAS

Perdidas ACU (KVA) 0.2748 0.1339 0.0407 0.0056 0.3036 0.2788 0.1185 0.0618 0.0145

% Perdidas

1.44

1.02

KW loss

SumKW loss

0.13355 0.08832 0.03324 0.00531

0.26042 0.12688 0.03855 0.00531

0.27413 0.13355 0.04058 0.00559

1.442

0.02351 0.15190 0.05376 0.04476 0.01377

0.28770 0.26419 0.11229 0.05853 0.01377

0.30284 0.27809 0.11820 0.06161 0.01449

1.021

17

3

9

KVA loss % loss

ÓN Y PERDIDAS Perdidas % Perdidas ACU (KVA) 0.1552 0.90 0.0792 0.0279 1.2137 0.7344 0.4214 0.1890 0.0270

3.47

0.5544 0.3162 0.2007 0.1146 0.0057 0.0057

1.73

4 25,2

2/0 30,5

4

7 5

4

6 14

ÓN Y PERDIDAS Perdidas % Perdidas ACU (KVA) 0.1320 0.81 0.0681 0.0230 1.4081 0.9011 0.5401 0.2034 0.0343

3.01

0.0343 0.0268

0.32

0.1993 0.1600 0.0892

0.96

3

7 2/0 25,4

2

18

7 13 2/0 24,4 14

7

3

ÓN Y PERDIDAS

Perdidas % Perdidas ACU (KVA) 0.1636 0.95 0.0473 0.0030

14 2

8 30 9 31.5

1

8

9

6

8

31

35

5

35

13

8 4

27

4

6 30

8 30 7 7 2 31.5 31 31 35 0 10 9 11 4 32

8

12

10

0.0543

0.47

1.1882 0.6191 0.2657 0.0672 0.0116 0.0116

3.20

0.5904 0.1754 0.0360

2.48

30 2

9 31.5

1

8

9

6

8

31

35

5

35

13

8 4

27

4

6 30

8 30 7 7 2 31.5 31 31 35 0 10 9 11 4 32

8

12

10

CALCULO DE TRANSFORMADOR TRANSFORMADOR 1

Estrato Bajo Bajo No. de Usuarios = 99 KVA Usuarios = 0,75 KVA Total = 74,36

Luminarias 70W = 7 Watios = 490 KVA = 0.516

KVA = KVA Total + KVA Luminarias KVA =

74.876

Según curva de cargabilidad en transformadores Trifasicos: Entre 48 - 81 (KVA) = Transformador de 75 KVA

TRANSFORMADOR 2

Estrato Bajo Bajo No. de Usuarios = 91 KVA Usuarios = 0,76 KVA Total = 69,52

Luminarias 70W = 7 Watios = 490 KVA = 0.516

KVA = KVA Total + KVA Luminarias KVA =

70.044

Según curva de cargabilidad en transformadores Trifasicos: Entre 48 - 81 (KVA) = Transformador de 75 KVA

TRANSFORMADOR 3

Estrato Bajo Bajo No. de Usuarios = 53 KVA Usuarios = 0,86 KVA Total = 45.39 KVA = KVA Total + KVA Luminarias

Luminarias 70W = 5 Watios = 350 KVA = 0.368

KVA =

45.758

Según curva de cargabilidad en transformadores Trifasicos: Entre 33 - 48 (KVA) = Transformador de 45 KVA

CALCULO DE TRANSFORMADOR TRANSFORMADOR 4

Estrato Bajo Bajo No. de Usuarios = 98 KVA Usuarios = 0,75 KVA Total = 73,76 KVA = KVA Total + KVA Luminarias KVA =

74.276

Según curva de cargabilidad en transformadores Trifasicos: Entre 48 - 81 (KVA) = Transformador de 75 KVA

Luminarias 70W = 7 Watios = 490 KVA = 0.516

VEREDA SAN JUAN CALCULO DE REGULACIÓN EN MEDIA TENSION Tramo

Conductor

Longitud (m)

KVA

Momento KVA *L

Regulación Parcial

Regulación Total

0.034 0.003 0.041 0.043 0.003 0.006 0.017 0.019 0.010 0.003

0.034 0.037 0.078 0.121 0.124 0.130 0.147 0.166 0.176 0.180

NODO ALIMENTADOR 2 (NA2) NA1-C1 C1-T1 C1-T5 T5-C2 C2-T7 C2-T8 C2-T9 T9-T13 T13-T11 T13-T10

1/0 1/0 1/0 1/0 1/0 1/0 1/0 1/0 1/0 1/0

113 85 158 193 81 175 112 212 180 90

607.5 75 532.5 457.5 75 75 307.5 187.5 112.5 75

68647.5 6375 84135 88297.5 6075 13125 34440 39750 20250 6750

75KVA

75KVA

T4

T7

45KVA 112.5KVA

75KVA

81

85

NA2

113

158

C1

T5

75KVA

193

112 175

T8

75KVA

T13

T9

T11 180

212 98

T10

75KVA

DIAGRAMA UNIFILAR TRANSFORMADOR 5

6 4

18

7 3

18

7 2

18

7 1

20

8 4

5 6 7 7 22 24 21 25 28 7

20

26

6 6 20 7 9 20

14 5 30 15 5 32

8 7

16 1

DIAGRAMA UNIFILAR TRANSFORMADOR 4

14 8 30 2

9 31.5

1

6 30

8 30 7 7 2 29 31 27 31.5 31 31 35 0 9 10 11 5 4 7 6 35 35 32 8 13 12 10 4 4

9

8

8

8

DIAGRAMA UNIFILAR TRANSFORMADOR 8

4

6

31 3

5

32 5

3 20

2 23 5 1 22

12 18 25 6 17 25 1

25 16

2 8

25

3

0 6 23 5 3 21

4 25 26 7 7 6 13

4

12

7

6 25 7 22 8 25 9

1

25 16

2 8

25

21

3

4 25 26 7 7 6 13

DIAGRAMA UNIFILAR TRANSFORMADOR 10

6 6 33 7 5 28 22 5 4 4 30 26 4 6 4 11 10 0 25 25 25 35 30 40 40 11 16 17 18 19 2 1 3 4 21 3 35 13 4 35 13 9 40 20 6 35 14 17 10

5

2/0

32.8

DIAGRAMA UNIFILAR TRANSFORMADOR 11

5 8

4

2/0 1/0

2/0

3 2/0

0

5 2

2/0

2/0

2

28

6

4

2/0

30

7

6

8

2/0

30

5

9 2/0 30

3

DIAGRAMA UNIFILAR TRANSFORMADOR 6

7 5

5

19

18

9 9 3 4 20 5 18 18 18 23 8 11 10 12 9 15 14 8 6 6 3 7 18 18 17 15 2 7 18

6 18 6 18 5 18 30 18 17 21 3 22 16 11 18 11 20

13

3

10 22

3

9

20 1 8

6

2 5

22

22

5 22

6

10

25 11 18 6 22 13 20

22 3

6

2

9

20 1 8

5

22

22

5 22

6

10

25 11 18 6 22 13 20

3 1

7 7 18 7 7 8 45 48 34 25 0 17 18 19 22 20

7 22

21 4 20 2 22 22 5 17 31 4 11 22 26 22 7 30 30 30 28 24 27 25 DIAGRAMA UNIFILAR TRANSFORMADOR 3

DIAGRAMA UNIFILAR TRANSFORMADOR 9

DIAGR

11 8 3 2/0 9

3 0

5 7

30 2/0

2 6

6

9

5

2/0 41

9

1 0

9

14

2/0

5

8

2/0

2/0

2/0

2/0

2/0

42

44

35

28

30

3

2

1

4

30

4

30 3 0

5

2/0 10

DIAGRAMA UNIFILAR TRANSFORMADOR 12

7

4 16

2/0

25

34 2/0

8 30

2/0

2 7 2

7 7

25

41 6

4

4

2/0

18

1

2/0

12

2/0

22

0

5

2/0

22

1 4 2/0

11

12

9

30

15

5

4 2/0

34

2/0

8

27

6

2/0

2/0

30

2/0

1

5

6 35

2/0

4 2/0

3 3

33

DIAG

5

34

19

DIAGRAMA UNIFILAR TRANSFORMADOR 2 11 2/0

9 35

4

8

2/0

24,4

3

3

5 2

2/0 30,5

8 1

7 2/0 24,3

2/0 31 18 0 2/0 6 2/0 3 2/0 12

DIAG

6 2/0

5

3

2/0

5

27

3

4

2/0 25,2

2/0 30,5

4

30

4

10 25,30 11 21,60 12

11

6

2/0 35,6

2/0 13

37

14

DIAGRAMA UNIFILAR TRANSFORMADOR 3

6 2/0

7 6 5

30

2/0 5

30

10

2/0

5 3 2/0 5

32.8

8

4

2/0

30

34

3

2/0 2

5

27.8

1

4

2 2/0 2.2

2/0 0

30

5

6 2/0

6

30

2/0 7

30

2/0 8

30

3

9

DIAGRAMA UNIFILAR TRANSFORMADOR 13

10

1

2/0 20

5

32

7 2/0

19 2/0

30

2/0 16

18

30

17

31 2/0

4

5

14

2 5 2/0

25 13

25

2/0

2/0 25

2/0

11

5

20

2/0

10

8

25

12

15

DIAGRAMA UNIFILAR TRANSFORMADOR 1

14

6 28,6

2/0 5

4

2/0 15

2 4

2/0 7

30

7 2/0 16

37

15 9

2/0

1 2/0

2/0 37

9 2/0

35,3

7

2/0 0

2/0

26.3

25,4

2

17,8 18

6 27,8 10

7

3

5

2

2/0 17

23

12 2/0

37,1

7

2/0 11

39

13 2/0 24,4 14

7

3

DIAGRAMA UNIFILAR TRANSFORMADOR 7

3 9 9

7 2/0

2/0 30

4

30

2/0 3

30

2/0 30

2

2/0

27

7

8

4

2/0 1

28

0 40

2/0

8

5

2/0 2/0

2

25.28 1 4

1 2

3 6

3 5

1 3

2/0 11

1 0 42

5

5 2/0

2 7

8 2/0 2 5

1 5

7 2/0

12

21

7

VEREDA SAN JUAN CALCULO DE REGULACIÓN EN BAJA TENSIÓN Y PERDIDAS

Tramo

Conductor Aluminio, quadruplex trenzado

0-1 1-2 0-3 3-4

Longitud

Usuarios

KVA

Momento

FC

Regulación

2/0 2/0

(m) 30 30

9 4

Demanda 19.06 3.76

KVA *L 571.8 112.8

1 1

Parcial 0.71 0.14

2/0 2/0

30 30

5 2

19.06 3.76

571.8 112.8

1 1

0.71 0.14

10

TRANSFORMADOR: CAPACIDAD: KVA USUARIOS: TIPO:

1 30 KVA 16.34 15 TRIFASICO

L. MEDIA: L. BAJA:

218 METROS 308,8 METROS

2/0

5 3 2/0

5 32.8

8

4

2/0

30

34

2/0

2/0 27.8

2 2

2.2

1 5

0

AN JUAN

cuadruplex ro asumido fp

BAJA TENSIÓN Y PERDIDAS

Regulación

Voltaje

Perdidas

Total 0.71 0.86

Corregido 206.51 206.22

(KW) 0.13 0.01

0.71 0.86

206.51 206.22

0.13 0.01

Perdidas

Perdidas

ACU. (KW) ACU (KVA) 0.1391 0.1464 0.0052 0.0055 0.1391 0.0052

0.1464 0.0055

% Perdidas

KW loss

0.77

0.00000 #REF!

0.77

#REF!

#REF!

4 2/0 30

5

6 2/0

6

30

2/0 7

30

2/0 8

30

3

9

0.5226 0.95

SumKW loss

KVA loss

#REF! #REF!

#REF! #REF!

#REF!

#REF!

#REF!

#REF!

17

% loss 0.768