Icp Oes Salsa Software.pdf

  • Uploaded by: Juan Urbina Guarniz
  • 0
  • 0
  • May 2020
  • PDF

This document was uploaded by user and they confirmed that they have the permission to share it. If you are author or own the copyright of this book, please report to us by using this DMCA report form. Report DMCA


Overview

Download & View Icp Oes Salsa Software.pdf as PDF for free.

More details

  • Words: 487
  • Pages: 23
ICP OES Software Prodigy’s Salsa Software Program

Starting Salsa

Key Operations  Methods

– – – – – – –

Development

Set Instrument conditions Wavelength alignment Background correction Interferences Calibration standards Calibration Quality Control

Set Conditions More on instrument control to follow. • Initiate plasma • Set view

Confirm Wavelength Alignment

Look at spectra of single element standards initially

Set Background Correction

Look at spectra of samples & standards

Interferences  Interfering

Elements

– Set background locations to correct – Select an alternate line – Apply inter-element corrections

Inter-Element Corrections 1

3 Select IEC Tab

Highlight interfering element and run standard

4 2 Identify interfering element for highlighted element

Highlight analyte to see its interferences

Calibration Standards

Edit individual values in table

Calibration

Quality Control  Adding

QCs is like adding standards

– Additional entry for acceptance range

Running Samples 

Manual or Automated?

Automated Operation Sequences

– Type of reading – Type of sample

Urgent Samples

Manual Operation Standards QCs Unknowns

Echellograms

Viewing Results  

  

  



Results Tab….. Scans Tab…… Profiles Tab…. Calc Valid….... Image………… Cntl Chrt……. Report………. Recalculate…… TRA………….

Numerical Values Detailed Spectral View Spectral Thumbnails Pixel Readings/calculations Detector view Graphical plot or readings Generate & output results Regenerate results with modified method Time resolved measurement (optional)

Results • View sync’d to navigator • Detail or statistics • Vies single sample or all

Scans • View one wavelength at a time. • View intensities. • Estimate concentration. • Linked to checkboxes

Profiles • View all wavelength simultaneously • Quick check backgrounds • Multiple pages • Linked to checkboxes • Double click one thumbnail to see it in Scans

Calc Validation • View intensities for binned pixels • Check calculations • Multiple pages • Linked to highlighted sample • Double click one thumbnail to see it in Scans

Image • View of entire detector with • Identify intensity • Display elemental lines • Display method lines

• Run qualitative analysis • Linked to sample highlighted

Ctrl Chrt • Easy way to track QCs or recurring samples • Set markers for acceptance ranges • Linked to sample checkboxes • View multiple wavelengths

Reporting Results • Select types of sample to report • Select samples to include

• Select detailed or statistics • Select lines to include • Select fields to display and order • Click Report button to display

Recalculating Results  View

all method conditions during reading  Change sample names  Modify method and update results  Change sample weight & volumes

Details Display Highlight a sample to view analysis details • Pixel info • Standard info • QC info • Calibration info Review, activate, clone or print method Recalculate with new weight & volume

Change Sample Names • Go to Results Tab • Highlight Chapter Name

• Select desired sample • Click Rename button • Select fields to display and order • Click Report button to display