FIU 19E Indoor Unit

Quick Reference Guide C34231.24--E0

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

Quick Reference Guide

The information in this documentation is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia's customers only for the purposes of the agreement under which the documentation is submitted, and no part of it may be reproduced or transmitted in any form or means without the prior written permission of Nokia. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products cannot be considered binding but shall be defined in the agreement made between Nokia and the customer. However, Nokia has made all reasonable efforts to ensure that the instructions contained in the documentation are adequate and free of material errors and omissions. Nokia will, if necessary, explain issues which may not be covered by the documentation. Nokia's liability for any errors in the documentation is limited to the documentary correction of errors. NOKIA WILL NOT BE RESPONSIBLE IN ANY EVENT FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCIDENTAL OR CONSEQUENTIAL (INCLUDING MONETARY LOSSES), that might arise from the use of this documentation or the information in it. This documentation and the product it describes are considered protected by copyright according to the applicable laws. NOKIA logo is a registered trademark of Nokia Corporation. Other product names mentioned in this documentation may be trademarks of their respective companies, and they are mentioned for identification purposes only. Copyright © Nokia Corporation 2005. All rights reserved.

Hereby, Nokia Corporation, declares that this Nokia FIU 19E indoor unit is in compliance with the essential protection requirements for EMC (as stated in Article 4 of Council Directive 89/336/EEC) specified under the article 3.1b of Council Directive 1999/5/EC (R&TTE Directive). Type approval information has been printed in the sticker on top of the FIU 19E main unit.

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

2

Quick Reference Guide

1. INSTALLING FIU 19E 1.1 Installing 1IU configuration (FIU 19E with 4 - 12x2M capacity) 1.

2.

3.

4.

5.

6.

3.

2.

1.

Figure 1. Installing 1IU configuration (4 - 12x2M capacity)

1. 2. 3. 4. 5.

Attach the mounting brackets to FIU 19E with M3x10 Torx screws (4 pcs). Attach the plug-in unit(s) into FIU 19E with M3x10 Torx screws. Attach the mounting nuts to the rack. Attach FIU 19E into the mounting rack with M6x15 mounting screws (4 pcs). Before tightening the M6x15 mounting screws, attach the grounding cable to the unit. NOTE Do not attach the other end of the grounding cable to the rack, as the rack does not ensure a proper grounding for the unit. Attach the grounding cable to the grounding rail of the premises.

6. Attach the Flexbus cable (1), power cable (2), and LMP cable (3) to FIU 19E. For commissioning instructions, see Section 2.1 Commissioning 1IU configuration.

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

3

Quick Reference Guide

1.2 Installing 1IU configuration (FIU 19E with 16x2M capacity) 1.

2.

3.

4.

5.

6.

7.

8.

3. 2.

1.

Figure 2. Installing 1IU configuration (16x2M capacity)

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

4

Quick Reference Guide

1. 2. 3. 4.

Attach the mounting brackets to the Expansion Unit (EXU) with M3x10 Torx screws (4 pcs). Attach the backplane to the EXU unit. Attach the mounting nuts to the rack. Screw the backplane guide pin to the backplane. Attach EXU to the rack with M6x15 mounting screws. 5. Remove the backplane cover plate and attach the mounting brackets to FIU 19E with M3x10 Torx screws (4 pcs). 6. Slide FIU 19E to the rack. Make sure to slide the guide pin into the hole at the back of the FIU 19E unit, before pushing the unit firmly into place. Attach the FIU 19E unit into the rack using mounting screws. 7. Before tightening the M6x15 mounting screws, attach the grounding cable to the unit. NOTE Do not attach the other end of the grounding cable to the rack, as the rack does not ensure a proper grounding for the unit. Attach the grounding cable to the grounding rail of the premises. 8. Attach the Flexbus cable (1), power cable (2), and LMP cable (3) to FIU 19E. For commissioning instructions, see Section 2.1 Commissioning 1IU configuration.

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

5

Quick Reference Guide

1.3 Installing 2IU protected configuration (FIU 19E with 16x2M capacity) 1.

2.

3.

4.

5.

6.

7.

8. 3. 2. 1.

5.

4.

Figure 3. Installing 2IU protected configuration (16x2M capacity)

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

6

Quick Reference Guide

NOTE When installing 2IU protected configuration, make sure to supply the power for each FIU 19E unit through its own fuse. This ensures the correct operation of the protection, in case of a short-circuit in one of the units. Before starting the installation of 2IU protected configuration, check also, that both FIU 19E units have the same product code and software version. 1. 2. 3. 4. 5.

Attach the mounting brackets to EXU with M3x10 Torx screws (4 pcs). Screw the backplane guide pins (2) to the backplane. Attach the mounting nuts to the rack. Attach the backplane to EXU and attach EXU to the rack with M6x15 mounting screws. Remove the cover plates from the back of the FIU units. Attach the mounting brackets to both FIU 19E units (=IU A and IU B) with M3x10 Torx screws (4 pcs). Note, that the installation of mounting brackets is different for IU A and IU B. 6. Attach FIU 19Es to the rack. a. Slide IU A into the rack above the EXU. Make sure to slide the guide pin into the hole at the back of the FIU 19E unit, before pushing the unit firmly into place. Attach IU A to the rack using M6x15 mounting screws. b. Slide IU B into the rack below the EXU. Make sure to slide the guide pin into the hole at the back of the FIU 19E unit, before pushing the unit firmly into place. Attach IU B to the rack using M6x15 mounting screws. 7. Before tightening the mounting screws, attach the grounding cable to the unit. NOTE Do not attach the other end of the grounding cable to the rack, as the rack does not ensure a proper grounding for the unit. Attach the grounding cable to the grounding rail of the premises. 8. Attach the Flexbus cables (1 and 4) to FB 1 of IU A and IU B, and power cables (2 and 5) to FIU 19E units. Attach the LMP cable (3) to the LMP port of IU A. For commissioning instructions, see Section 2.2 Commissioning 2IU protected configuration.

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

7

Quick Reference Guide

1.4 Installing FIU 19E to TM4 rack 1.

2. T55241.06

310 mm T55241.04

14 holes 482.6 mm (19" ) 11 U T55241.04

Figure 4. Installing FIU 19E to TM4 rack

1. Place the upper and lower supports (T55241.04) as shown in the figure Installation of FIU 19E to TM4 rack. Leave 14 holes between the supports. Attach the upper and lower supports to the rack (T55241.06) using four M4x10 screws. 2. Attach the mounting brackets to FIU 19E, slide the unit to the rack and attach the unit with M6x15 mounting screws. NOTE For information on the installation of FIU 19E to an ETSI rack, see document Installing Hardware for Nokia FlexiHopper (Plus) C2.3.

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

8

Quick Reference Guide

1.5 FIU 19E connectors 4

3

2

1

Molex Micro-Fit connector 1 VPB (+) 2 VNB (-) 3 Not connected 4 Not connected

TNC connector

FB1 +DC FB2 +DC

Power supply input of -40.5 to -72 V DC

PWR - +

12345678

SMB connector

MP

RJ-45 connector 1 Data out+ 2 Data out 3 Data in+ 6 Data in -

10/100 BaseT Ethernet 12345678

RJ-45 connector 4 GND 5 LMP in 6 LMP out

12345678

RJ-45 connector 3 4 5 6

Q1 out + Q1 in+ Q1 in Q1 out -

Q1-1 Q1-2

LMP

Figure 5. FIU 19E connectors

1.6 Installing plug-in units to FIU 19E

FIU 19E MP

Slot 1

Slot 2

LMP

PWR

- + 10BaseT Q1-1 Q1-2

FB1 +DC

FB2 +DC

Slot 3 4 x 2M plug-in units Aux data plug-in units (Max. 2 Aux data plug-in units) Ethernet plug-in unit Flexbus plug-in unit

Figure 6. Positioning of plug-in units in FIU 19E

NOTE You can only install two Aux data plug-in units into one FIU 19E unit. When installing two Aux data plug-in units into FIU 19E, use either slots 1 and 2, or 1 and 3, but not slots 2 and 3.

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

9

Quick Reference Guide

1.7 EXU and E1 connectors

EXU slot A (4A)

2M interfaces

EXU slot B (4B)

16x2M IC plug-in unit

4

3

2

1

2M 120

TQ connector 1 In 2 In+

RJ-45 connector 12345678

1

Out+

SMB connector

2M 75

2

Out -

3

Out -

4

In+

4

Out+

5 In 3, 6 - 8 Not connected

2M 120

Figure 7. EXU connector options

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

10

Quick Reference Guide

1.8 FIU 19E Ethernet plug-in unit

ETH-1

12345678

ETH-2

RJ-45 connector 1 Data out+ 2 Data out 3 Data in+ 6 Data in -

10/100 BaseT Ethernet

Figure 8. Ethernet plug-in unit and RJ-45 connector pinout

CAUTION Ethernet plug-in unit (T55320.01) is compatible with FIU 19E release C2.0 (T55340.01--D) hardware and P55306.01--A (or newer) software, when Hopper Manager C4.6 (or newer) is in use. The unit is not compatible with previous HW or SW versions of FIU 19E. The installation of the Ethernet plug-in unit is allowed only to slot 2 of the FIU 19E main unit. Pins 4, 5, 7, and 8 on the Ethernet plug-in unit interfaces (ETH-1/ETH-2) are terminated to improve noise margin.

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

11

Quick Reference Guide

1.9 Flexbus plug-in unit

FB3

4

3

2

1

DC IN

DC IN

FB4

Molex Micro-Fit connector 1 not connected 2 not connected 3 P55V 4 N55V = GND

Power supply input of +52 to +60 VDC

Figure 9. Flexbus plug-in unit and power connector pinout

CAUTION In Flexbus plug-in unit, the negative input voltage is grounded. If positive grounding is used at the equipment station, the plug-in unit requires an external, galvanically isolated power supply,

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

12

Quick Reference Guide

FIU 19E and Flexbus plug-in unit power connections

+48...+60 V

Outdoor unit Flexbus cables

FB4

FB3

FB2 +DC

FB1 +DC

Mast

+52...+60 V

+ _

2)

-40.5...-72 V 1) _

+

3)

Flexbus plug-in unit

Flexbus interface

Power supply FIU 19E Floating input Power supply secondary side is galvanically isolated from primary side FIU 19E

Grounding 1) Power requirement 70W - 2 x OU+1 x FIU19E 45W - 1 x OU+1 x FIU19E

2) In Flexbus plug-in unit, negative supply voltage is always grounded

3) In this site, positive supply voltage is grounded. Negative voltage could be grounded as well.

Figure 10. FIU 19E and Flexbus plug-in unit power connections

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

13

Quick Reference Guide

2. COMMISSIONING TASK LIST 2.1 Commissioning 1 IU configuration 1. Switch the power on to FIU 19E. 2. Check that the LMP cable has been connected between the PC and the indoor unit. Start Nokia Hopper Manager. 3. Connect to the network element by clicking Manage → Connect Locally. Once connected, run the Commissioning Wizard by clicking Manage → Commission. 4. Fill in the basic settings in the wizard. a. Give the site information (optional). b. Select station type and operating mode. c. Set Flexbus (outdoor unit) capacities. Tick ‘In use’ and click Next. d. Set Q1 and LMP port baud rates and addresses, if Q1 is used for node management. e. Select the Q1 bus routing, if Q1 is used for node management. f. Nokia FlexiHopper OU: Set the transmit frequency, maximum transmit power, and interleave mode. Switch on the Tx power. g. Nokia MetroHopper OU: Give master/slave settings, temporary hop ID, interleave mode, and channel selection method (manual/autosearch). h. Set installation information (optional) and the node clock. i. Check and approve settings. 5. Fine-align the antenna. When the antennas at the both ends of the hop have been aligned, verify that the Rx input level determined by the transmission planning is met. 6. Make the appropriate cross-connections with the Hopper Manager.

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

14

Quick Reference Guide

Figure 11. 1IU configuration successfully installed and commissioned

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

15

Quick Reference Guide

2.2 Commissioning 2IU protected configuration CAUTION Before starting the 2IU protected configuration commissioning, ensure that IU B is switched off. 1.

Switch the power on to IU A, but leave IU B switched off.

2.

Connect the LMP cable between the PC and IU A. Start Nokia Hopper Manager, and check the COM port number and speed of the connection.

3.

Connect to the network element by clicking Manage → Connect Locally. Once connected, run the Commissioning Wizard by clicking Manage → Commission.

4.

Do not bring Flexbus 1 into use, install the licences, or type in the identification information. In all windows click Next.

5.

Set the Protection Equipment to 2IU+2OU Protected.

6.

Click Finish, and answer ‘Yes’ to the question about resetting the indoor unit.

7.

After Nokia Hopper Manager has performed the reset, wait until the node manager action is completed (about 60 seconds) and switch the power on to IU B. Do not move the LMP cable from IU A to IU B.

8.

Wait 30 seconds for IU B to start.

9.

Close Nokia Hopper Manager and start it again. The Equipment View displays two indoor units and an expansion unit (although some equipment may appear ghosted or disabled).

10. Run the Commissioning Wizard. 11. Tick IU A – Flexbus 1 and IU B – Flexbus 1 on the list and click Start. When the Flexbuses have been discovered, click Next. 12. Install the necessary licences. Click Next. 13. Add network element indentification information. Click Next. 14. Set the Flexbus capacity and click the ‘In use’ tab (In use IU A and In use IU B). Click Next. 15. Configure the branching for the Q1 management. Click Next. 16. Make the outdoor unit settings. Click Next. 17. Check that the network element information summary is correct and send the information to the network element. 18. Add installation details (time, date, and installer information). Tick ‘Reset performance counters’ and ‘Reset RX level alarm’. Click Finish. dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

16

Quick Reference Guide

19. Fine-align the antenna. When the antennas at the both ends of the hop have been aligned, verify that the Rx input level determined by the transmission planning is met. CAUTION Do not change the protection mode after both indoor units have been switched on.

Figure 12. 2IU protected configuration successfully installed and commissioned

For more information on the installation and alignment of the antenna, see Nokia FlexiHopper (Plus) C2.3 Outdoor Unit Quick Reference Guide and Installing Hardware for Nokia FlexiHopper (Plus) C2.3.

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

17

Quick Reference Guide

APPENDICES Aux data plug-in unit and signaling pinout

AS V11 ASCK

AF V11 I/O

AS RS AFCK

AF703 I/O

Interface

Pin

Pin name

Signal / direction

AS V11 ASCK

1 2 3 4 5 6 7 8

Ground ASOUTP ASOUTN ASINP ASINN ASRXCKP ASTXCKP DOUT0

V.11 (Aux slow RX +) / out + V.11 (Aux slow RX -) / out V.11 (Aux slow TX +) / in + V.11 (Aux slow TX -) / out V.11 (Aux slow clock RX direction) / out V.11 (Aux slow clock TX direction) / out +/- Relay control / out

AF V11 I/0

1 2 3 4 5 6 7 8

Ground AFOUTP AFOUTN AFINP AFINN DIO0 DIO1 DOUT1

V.11 (Aux fast data RX +) / out + V.11 (Aux fast data RX -) / out V.11 (Aux fast data TX +) / in + V.11 (Aux fast data TX -) / in Digital I/O (TTL) /in/out Digital I/O (TTL) /in/out +/- Relay control / out

AS RS AFCK

1 2 3 4 5 6 7 8

Ground AFTXCKP AFTXCKN AFRXCKP AFRXCKN RXD232 TXD232 DOUT2

V.11 (Aux fast clock TX direction +) / in + V.11 (Aux fast clock TX direction -) / in V.11 (Aux fast clock RX direction +) / out + V.11 (Aux fast clock RX direction -) / out RS-232 (aux slow RX) / out RS-232 (aux slow TX) / in +/- Relay control / out

AF703 I/0

1 2 3 4 5 6 7 8

Ground 703RXP 703RXN 703TXP 703TXN DIO2 DIO3 DOUT3

G.703 RX 64 kbit/s, coding HDB3 +) / out + G.703 RX 64 kbit/s, coding HDB3 -) / out G.703 TX 64 kbit/s, coding HDB3 +) / in + G.703 TX 64 kbit/s, coding HDB3 -) / in Digital I/O (TTL) / in/out Digital I/O (TTL) / in/out +/- Relay control / out

dn0170994 Issue 6 en

© Nokia Corporation Nokia Proprietary and Confidential

18

Quick Reference Guide

FIU 19E LMP cable connection RJ-45 on front of FIU 19E 12345 678

D9 (female) on the cable 6 5

LMP out LMP in

4

GND

1-3, 7-8 nc

LMP-port

dn0170994 Issue 6 en

1 2 3 4 5 6 7 8 9

nc RD TD nc GND nc nc nc nc

© Nokia Corporation Nokia Proprietary and Confidential

5

4

9

3

8

2

7

1

6

GND = ground RD = received data TD = transmitted data nc = not connected

19