Cálculos de las potencias de las instalaciones

Potencias de las instalaciones

W

VA

KVA

Potencia activa instalada

52845.0

-

52.85

Potencias reactiva instalada

42419.0

25591.80

25.59

Potencia total instalada

68010.8

-

68.01

Máxima demanda

9213.1

-

-

Potencia contratada

9213.1

-

-

Potencia subestación

24483.89

27204.32

27.20

Potencia grupo electrógeno

24483.89

27204.32

27.20

Conversión de la potencia reactiva instalada de W a VAR

S Potencia aparente P potencia reactiva (VA)

P potencia activa (Watts)

Si sabemos que: cos 𝜑 = 0.9 Hallaremos φ Arcoseno( 0.9) = 𝜑

𝜑 = 25.84 Tenemos que: 𝑡𝑎𝑛𝜑 =

𝑄 𝑃

Donde : Q=Potencia reactiva (VA) P= Potencia Activa (W)

𝑄 = 𝑃 ∗ tan 𝜑 𝑄 = 52845 ∗ tan 25.84 𝑄 = 25591.80 𝑉𝐴 𝑄 = 25.59 𝐾𝑉𝐴 Potencia total instalada 𝑃𝑡𝑜𝑡𝑎𝑙 𝑖𝑛𝑠𝑡𝑎𝑙 = 𝑃𝑎𝑐𝑡𝑖𝑣𝑎 + 𝑃𝑟𝑒𝑎𝑐𝑡𝑖𝑣𝑎 𝑃𝑡𝑜𝑡𝑎𝑙 𝑖𝑛𝑠𝑡𝑎𝑙 = 25591.80 + 42419.00 𝑃𝑡𝑜𝑡𝑎𝑙 𝑖𝑛𝑠𝑡𝑎𝑙 = 68010.8 𝑊 Máxima demanda 𝑀. 𝐷 = 𝑃 ∗ 𝑓. 𝑠 ∗ 𝑓. 𝑑 Donde: P= Potencia activa (W) f.s= Factor de seguridad (0.5-0.7) f.d= facto de demanda (0.5-0.7)

𝑀. 𝐷 = 25591.80 ∗ 0.6 ∗ 0.6 𝑀. 𝐷 = 9213.05 𝑊

𝑴. 𝑫 = 𝑷 𝒄𝒐𝒏𝒕𝒓𝒂𝒕𝒂𝒅𝒂

Potencia de subestación 𝑃𝑠𝑢𝑏𝑒𝑠𝑡𝑎𝑐𝑖𝑜𝑛 = 𝑃𝑡𝑜𝑡𝑎𝑙 𝑖𝑛𝑡𝑎𝑙𝑎𝑑𝑎 ∗ 𝑓. 𝑠 ∗ 𝑓. 𝑑 𝑃𝑠𝑢𝑏𝑒𝑠𝑡𝑎𝑐𝑖𝑜𝑛 = 68010.8 ∗ 0.6 ∗ 0.6 𝑃𝑠𝑢𝑏𝑒𝑠𝑡𝑎𝑐𝑖𝑜𝑛 = 24483.89 𝑊 Convirtiendo a VA 𝑃 = √3 ∗ 𝑉 ∗ 𝐼 ∗ 𝑐𝑜𝑠𝜑 𝑃(𝑊) = 𝑆(𝑉𝐴) ∗ 𝑐𝑜𝑠𝜑 24483.89 𝑊 = 𝑆(𝑉𝐴) ∗ 0.9 𝑆(𝑉𝐴) =

24483.89 0.9

𝑃 = 27204.32

𝑷𝒐𝒕𝒆𝒏𝒄𝒊𝒂 𝒔𝒖𝒃𝒆𝒔𝒕𝒂𝒄𝒊𝒐𝒏 = 𝑷𝒐𝒕𝒆𝒏𝒄𝒊𝒂 𝒈𝒓𝒖𝒐𝒑𝒐 𝒆𝒍𝒆𝒄𝒕𝒓𝒐𝒈𝒆𝒏𝒐