1.

2. 3. a) b) 4. 5. 6. 7. 8.

ELECTRICAL NOTES: ALL ELECTRICAL INSTALLATION WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THESE PLANS & SPECS, AND THE APPLICABLE PROVINSIONS OF THE PHILIPINE ELCTRICAL CODE, IT’S APPLICABLE LAWS AND ORDINANCES THE CITY/ MUNICIPALITY AND THE REQUIREMENTS OF THE UTILITY POWER COMPANY. THERE SHALL BE ONLY ONE SERVICE DROP TO THE BUILDING. THE POWER SUPPLY SHALL 230 VOLTS, 3 PHASE, 60 HERTZ. THE ELECTRICAL WIRING INSTALLATION SHALL BE DONE IN PVC PIPE. IF NOT INDICATED OR SPECIFIED, IT SHALL BE DONE AS FOLLOWS: SERVICE ENTRANCE- RiGID STEEL CONDUIT(RSC) OR INTERMEDIATE METTALIC CONDUIT(IMC). UNDERGRUOND & EMBEDDED IN CONCRETE SLAB & WALLS- PVC CONDUIT PIPES SCHEDULE 40. FLEXIBLE CONDUITS SHALL BE USED ONLY AS RACEWAY FOR DROP WIRE OF LIGHTING FIXTURE. ALL WIRES SHALL BE COPPER & THERMOPLASTIC INSULATED TYPE “THHN” UNLESS OTHERWISE INDICATED. USE PHELPS DODGE OR COLUMBIA BRAND. THE CONTRACTOR SHALL VERIFY & ORIENT THE ACTUALL LOCATION OF SERVICE ENTRANCE FOR CONNECTION TO THE POWER SUPPLY. ALL SERVICE ENTRANCE EQUIPMENT, SWITCHES, PANEL BOARDS, LIGHTING FIXTURES ALL NON-CURRENT CARRYING METAL PARTS SHALL BE PROPERLY GROUNDED. ALL FEEDERS & BRANCH CIRCUIT HOMERUNS SHALL BE INSTALLED AS INDICATED ON THE PLANS. BRANCH CIRCUIT HOMERUN WIRES SHALL BE INSTALLED IN INDIVIDUAL HOMERUN CONDUITS. ANY DISCREPANCY IN LOCATION & RATINGS OF EQUIPMENT AND/OR APPARATUS TO BE INSTALLED SHALL BE VERIFIED WITH THE OWNER OR HIS AUTHORIZED REPRESENTATIVE, & CHANGES SHALL BE MADE ACCORDINGLY.

9. 10. 11.

12. 13. 14. 15.

ELECTRICAL NOTES: ALL MATERIALS & EQUIPMENTS TO BE USED & INSTALLED SHALL BE BRAND NEW, OF THE APPROVED TYPE FOR THE LOCATION AND PURPOSE INTENDED. ALL POWER & CONVINENCE OUTLETS SHALL BE GROUNDING TYPE. THE MOUNTING HEIGHTS OF WIRING DEVICES SHALL BE AS FOLOWS: a. LIGHT SWITCHES - 1.40M. ABOVE FINISH FLOOR LINE b. CONVINIENCE OUTLETS - 0.30M. ABOVE FINISH FLOOR LINE c. TELEPHONE OUTLETS - 0.30M. ABOVE FINISH FLOOR LINE d. PANEL BOARDS & CABINETS – 1.40M. ABOVE FINISH FLOOR LINE FOR EACH SPARE BRANCH CIRCUIT IN THE PANEL BOARD, PROVIDE ONE 15 mm. dia. PVC PIPE WITH 3.5 mm. sq. THHN CU. WIRE TERMINATED TO 100 mm JUNCTION BOX ABOVE THE CEILING. ALL FEEDERS AND BRANCH CIRCUITS SHALL BE INSTALLED AS INDICATED ON PLANS, INDIVIDUAL CIRCUIT HOMERUNTO PANEL BOARD AND SWICHES OF DIFFERENT CIRCUITRY SHALL NOT BE COMBINED IN THE SAME RACEWAY. PROVIDE 20 MM DIA. PVC CONDUIT FROM WATER PUMP OUTLET TO OVER HEAD TANK FOR CONTROL WRES(FLOAT SWITCH). THE ELECTRICAL WORK SHALL BE UNDER THE IMMEDIATE SUPERVISION OF A DULY LICENSED REGISTERED ELECTRICAL ENGINEER OR MASTER ELECTRICIAN.

ELECTRICAL SYMBOLS: PANEL BOARD (THE NUMBERS INDICATES LIGHTING PANEL NUMBER) DUPLEX CONVENIENCE OUTLET

PB

WEATHERPROOF OUTLET

WP

COUNTER HEIGHT OUTLET

CH

RANGE OUTLET

RANGE

REFRIGERATOR OUTLET

Ref

SERVICE ENTRANCE (INDICATE THE NUMBER OF CONDUCTOR, SIZE,TYPE AND VOLTAGE) SERVICE KILOWATT-HOUR METER FLOURSCENT INCANDESCENT LIGHT OUTLET FLOURSCENT LAMP 32 WATTS TELEPHONE OUTLET

TEL

CABLE OUTLET

CATV

LOAD SCHEDULE

LOAD SCHEDULE

LOAD SCHEDULE

LOAD COMPUTATION