PROJECT NAME : SAVAR CANTT SUPER MARKET JOB NAME : ELECTRICAL WORK PE S.N.
description
unit
Qn.ty
Unit rate 53820.00
amount
1.
Lightning arrester: Supply, installation, testing and commissioning of indoor/outdoor type 33 KV, 50 Hz, 140A, (7 KA), 230 KV BIL lightning arrester complete with mounting accessories etc. Manufactured by GEM Co. Ltd, Bangladesh or equivalent product of USA / UK / Germany / Switzerland /France origin. (3 nos. in a set).
set
01
53820.00
2.
33KV AUTOMATIC VOLTAGE REGULATOR:
set
01
138100.00
138100.00
set
01
140000.00
140000.00
Supply, Installation, Testing & commissioning of type tested 140A (min.), 19.08KV, 3 nos. (1 set) of single phase, indoor/outdoor type Automatic Voltage Regulator (AVR) in sealed tank design as per Technical Specification with the following data. The AVR must comply with the latest requirements of BPDB. The work shall be completed with 33KV By-Pass switch including all necessary accessories to complete the installation. Rated Current: 140A (min.) Rated Voltage: 19.08KV Single phase/33KV three phase, 50 Hz. Voltage Regulation: ±10% in 32 steps or 5/8% each Complete with following spares for the above Regulation - 6 nos. Fuses - 2 nos. Position Indicator Glass - 6 nos. Oil sight glass 3.
H.T. SWITCHGEAR Supply, installation, testing and commissioning of type tested locally assembled confirming to IEC 298/694 high voltage switch gear (33KV) of sheet steel clad, dust and vermin proof, free standing, floor mounting, indoor type, 33KV,50Hz, 210A (min.), 350 MVA rated capacity. The switchgear shall be inclusive of withdrawable type Vacuum circuit Breaker (VCB), CT, PT, relay, ammeter, voltmeter, energy meter, bus-bar, interlocked earth switch, internal wiring etc all equipment and accessories complete as per design, specification, standard, and instruction of Engineerin-charge. The switchgear must comply with the requirement of relevant local Authority. The components shall be manufactured and tested in UK/USA/Germany/Japan/France. Incoming Feeder : 1 No. 33KV, 50HZ, 7KA (1 sec), Earthing switch to be interlocked with the vacuum circuit breaker 1 No. 210A, 33KV, 50HZ, 7KA (3 sec) triple pole totally withdrawable horizontal isolation type Vacuum Circuit Breaker with both manual and motor operated mechanism with closing solenoid, trip button, shunt releases, operating cycle counter, 6 N/O + 6 N/C contacts, mechanical ON/OFF indicators etc. 2 Nos. 33KV cast resin insulated, double pole potential transformer having ratio 33000/110V, class 0.5, of 50VA burden (in open delta connection) for metering and protection.
1 No. of TP MCB for PT secondary protection. 3 Nos. of cast resin insulated 33 KV double core current transformer having ratio 140/5/5A Core-1, 10VA. Class 0.5M10 Core-2, 15VA, Class 10 P10 1 No. of 0-15KV voltmeter with selector switch 1 No. of 0-140A Ammeter with selector switch 1 No. 3 phase 3 wire, two part time of the day solid state microcomputer operated digital KWH meter with indicating "PEAK" & OFF PEAK energy with maximum demand indicator in KW with integrating time of 30 minutes. 1 No. of synchrous time switch for double tariff operation of KWH meter 3 Nos. of indicating lamps (ON/OFF/TRIP) 1 No. of panel heater with thermostat 3 Nos of indicating lamp for presence of three phase (R.Y.B.) 1 No. of operating handle. 1 No. of Triple pole solid state micro processor operated IDMT relay with 2 (two) over current and 1 (one) earth fault protection element with standard settings. Outgoing Feeders: 2 nos. outgoing Feeder, each shall be equipped with the following: 1 No. 33KV, 50HZ, 7KA (1 sec.) Triple pole Earthing switch to be interlocked with Vacuum Circuit Breaker 1 No. of 210A, 33KV, 50Hz, 7KA (3 sec) rupturing capacity, Tripole, totally withdrawable horizontal isolation type of Vacuum Circuit Breaker with both manual & motor operated mechanism with closing solenoid, Trip button, shunt releases, operating cycle counter, 6 N/O + 6 N/C anxillary contacts, mechanical ON/OFF indicator etc 1 No. 33KV cast resin insulated, double pole potential transformer having ratio 33000/110V, class 0.5, of 50VA burden (in open delta connection) for metering and protection. 3 Nos. of cast resin insulated double core current transformer having ratio 110/5/5A, Core -1, 10VA, class 0.5M10 Core - 2, 15VA, class 10P10 1 No. of 0-110A Ammeter with selector switch 3 Nos. of indicating lamp for the presence of three phases (R.Y.B.) 3 Nos. of indicating lamp (ON/OFF/TRIP) 1 No. of operating handle 1 No. of Triple pole solid state microprocessor operated IDMT relay with 2 (two) over current and 1 (one) earth fault protection element with standard settings The tripping coil of the circuit breakers shall be activated by a capacitor storage tripping device without DC (battery) supply source for trip coil. 4.
TRANSFORMER Supply, installation, testing and commissioning of following dry type cast resin, natural air cooled, 3-phase, 50 Hz, 33/0.415KV indoor type distribution Transformer of DYN11 vector group having percentage impedance 4 - 6%, basic impulse insulation level 3000KV, HV & LV bushings, complete with two windings , earthing terminals, temperature sensor with thermometer, lifting lugs, name plate arranged on tank top, conservator, oil level indicator, drain and filling valves, bi-directional rollers, with first filling of oil in Transformer etc. complete as required and suitable for operation at
set
02
6200000.00
12400000.00
400C ambient temperature with maximum temperature rise 1000C, manufactured and tested in UK/USA/Germany/Japan/France in accordance with IEC/NEMA /VDE/BSS/JIS standard. technical Data: -Rated Capacity : 3150 KVA -Rated Frequency : 50 Hz Rated Voltage, -Primary : 33000 V -Secondary : 415 V Rated Current -Primary : 55.11 A -Secondary : 4390 A Vector Group : DYN 11 Off-load tap changer : ± 2.5% , -5%, -7.5% Ambient Temperature : 40°C Temperature rise : - in Oil : 60°C (Max) - in Coil : 65°C (Max) Star point brought out & loadable upto : 100% Max. service altitude : 1000 Meters Installation : Indoor : 5200 watts (approx.) No load losses : 25000 watts (approx.) Full load losses Impedance : 6% (approx) Tolerances, As per IEC 60076 : Total Losses : + 10% of the total losses Component losses : + 15% of each component loss, provided that the tolerance for total losses is not exceeded Impedance voltage at rated ± 10% of the declared current (principal tapping Impedance voltage for that tapping. Accessories: -Silica gel breather -Dial type thermometer with trip & alarm contact. -Pressure relief device. -Buchholz relay with trip & alarm contact. 5.0
L.T SWITCHGEAR Supply, installation, testing and commissioning of 415V, 3-phase, 50 Hz, indoor type low tension switchgear of following specification complete with voltmeter (0-600V) & ammeter of adequate rating both with selector switch, indicting lamps for ONOFF and following components manufactured in UK/USA/Germany/Japan/France, locally factory assembled in 16 SWG sheet steel clad, dust & vermin proof, free standing, floor mounting epoxy resin powder coat painted cabinet. (MCCB's in LT panel must comply NEMA/VDE/IEC/JIS/BSS standard)
5.1
LT PANEL Incoming: 1 Set- 415V, 8000A, TPN&E hard drawn electrolytic insulated copper busbar. 1 x 6000A, 80KA, Triple pole fixed type Metal clad Air Circuit
set
02
162000.00
324000.00
Breaker with motor operated electronic controlled time dependent selectively operating with built in adjustable overload, adjustable short circuit protection, under voltage releases and auxiliary contacts. 3 Nos. - 415V, 5000/5A ratio current transformer with suitable accuracy and burden. 1 - Ammeter 0-5000A with selector switch 1 - Volt meter (0-500/600V) with selector switch 1 - Push button trip 3 - Indicating lamps (ON/OFF/TRIP) 3 - Indicating lamps for R.Y.B. phases. Outgoing: 1x1000A (50KA), TP MCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 1x800A (50KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 5x160A (35KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 5x100A (25KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 5x63A (25KA), TPMCCB with thermal overload and instantaneous Electro-magnetic short circuit release. 5.2
LT PANEL-1 Incoming: 1 Set- 415V, 8000A, TPN&E hard drawn electrolytic insulated copper busbar. 1 x 5000A, 80KA, Triple pole fixed type Metal clad Air Circuit Breaker with motor operated electronic controlled time dependent selectively operating with built in adjustable overload, adjustable short circuit protection, under voltage releases and auxiliary contacts. 3 Nos.- 415V, 5000/5A ratio current transformer with suitable accuracy and burden. 1 - Ammeter 0-5000A with selector switch 1 - Volt meter (0-500/600V) with selector switch 1 - Push button trip 3 - Indicating lamps (ON/OFF/TRIP) 3 - Indicating lamps for R.Y.B. phases. Outgoing: 1 x 3200A, 65KA, Triple pole with fixed type Metal clad Air Circuit Breaker with motor operated electronic controlled time dependent selectively operating with built in adjustable overload, adjustable short circuit protection, under voltage releases and auxiliary contacts. 1 x 1600A, 65KA, Triple pole with fixed type Metal clad Air Circuit Breaker with motor operated electronic controlled time dependent selectively operating with built in adjustable overload, adjustable short circuit protection, under voltage releases and
set
01
126000.00
126000.00
auxiliary contacts. 2x1250A (65KA), TP MCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 2x1000A (50KA), TP MCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 1x800A (50KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 3x160A (35KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 5x100A (25KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 6x63A (25KA), TPMCCB with thermal overload and instantaneous Electro-magnetic short circuit release. 5.3
BUS COUPLER Supply, installation, testing and commissioning of 1x5000A, 80KA TP+N withdrable type, metal clad Air Circuit Breaker with motor and manual operated electric controlled time dependent selectively ACB with built in adjustable overload and short circuit protection, under voltage release & will be auxiliary contracts. This will be used as BUS COUPLER between the NORMAL LT PANEL-1 & NORMAL LT PANEL-2. This breaker and the main incoming breakers of NORMAL LT PANEL-1 & NORMAL LT PANEL-2 shall be electrically interlocked such that this bus coupler breaker can only be closed if either one of the main incoming breaker is opened with components manufactured in UK/USA/Germany/Japan/France.
set
01
200000.00
200000.00
5.4.
LT PANEL-2 Incoming: 1 Set- 415V, 8000A, TP&NE hard drawn electrolytic insulated copper busbar. 1 x 6000A, 80KA, Triple pole fixed type Metal clad Air Circuit Breaker with motor operated electronic controlled time dependent selectively operating with built in adjustable overload, adjustable short circuit protection, under voltage releases and auxillary contacts.
set
01
110000.00
110000.00
3 Nos. - 415V, 5000/5A ratio current transformer with suitable accuracy and burden. 1 - Ammeter 0-5000A with selector switch 1 - Volt meter (0-500/600V) with selector switch 1 - Push button trip 3 - Indicating lamps (ON/OFF/TRIP) 3 - Indicating lamps for R.Y.B. phases. Outgoing: 1 x 6000A, 80KA, Triple pole fixed type Metal clad Air Circuit Breaker with motor operated electronic controlled time dependent selectively operating with built in adjustable overload, adjustable short circuit protection, under voltage releases and auxiliary
contacts. 1 x 3200A, 65KA, Triple pole fixed type Metal clad Air Circuit Breaker with motor operated electronic controlled time dependent selectively operating with built in adjustable overload, adjustable short circuit protection, under voltage releases and auxillary contacts. 3x160A (35KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 5x100A (25KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 6x63A (25KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 6.5
LT PANEL-AC Incoming: 1 Set- 415V, 8000A, TP&NE hard drawn electrolytic insulated copper busbar. 1 x 6000A, 80KA, Triple pole fixed type Metal clad Air Circuit Breaker with motor operated electronic controlled time dependent selectively operating with built in adjustable overload, adjustable short circuit protection, under voltage releases and auxiliary contacts.
set
01
96000.00
96000.00
set
01
100000.00
100000.00
3 Nos. - 415V, 5000/5A ratio current transformer with suitable accuracy and burden. 1 - Ammeter 0-5000A with selector switch 1 - Volt meter (0-500/600V) with selector switch 1 - Push button trip 3 - Indicating lamps (ON/OFF/TRIP) 3 - Indicating lamps for R.Y.B. phases. Outgoing: 7 x 1000A, 65KA, Triple pole fixed type Metal clad Air Circuit Breaker with motor operated electronic controlled time dependent selectively operating with built in adjustable overload, adjustable short circuit protection, under voltage releases and auxillary contacts. 18x125A (50KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 10x100A (25KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 20x(10-40A (25KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 5.6
ESSENTIAL LT PANEL Incoming: 1 Set- 415V, 1500A, TP&NE hard drawn electrolytic insulated copper busbar. 1x800A (50KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release
3 Nos.- 415V, 800/5A ratio current transformer with suitable accuracy and burden. 1 - Ammeter 0-800A with selector switch 1 - Volt meter (0-500/600V) with selector switch 1 - Push button trip 3 - Indicating lamps (ON/OFF/TRIP) 3 - Indicating lamps for R.Y.B. phases. Outgoing: 1x320A (35KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 1x260A (35KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 2x200A (35KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 3x160A (35KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 5x100A (25KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 6x63A (25KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release 10x40A (25KA), TPMCCB breaker with thermal overload and instantaneous Electro-magnetic short circuit release
6.
P.F.I. PLANT Supply, installation, testing and commissioning of following 415 volt, 3 phase, 50 Hz power factor improvement plants complete with TP busbars and earth block micro processor control auto power factor correction ralay with digital PF reading display, capacitor bank, contactor, fuse, ON/OFF indiators for every stage of capacitor bank (except directly connected one) etc. locally factory assembled in 16 SWG sheet steel clad dust & vermin proof, free standing, floor mounting, epoxy resin powder coat painted cabinet. contactors, capacitor bank, relays, discharge resistor, fuse etc. shall comply MENA/VDE/IEC/JIS/BSS standard and shall be manufactured in UK/USA/Germany/Japan/France. PFI CAPACITY 1900 KVAR 3 Nos.- 415V, 3200A hard drawn electrolytic insulated copper busbar 1 No.- 415V, 100 KVAR, 50Hz TP Power capacitor bank with built-in/separate discharge coil for connection directly with line through fuse. 2 Nos.- 415V, 25 KVAR, 50Hz TP Power capacitor bank with built-in/separate discharge resistor. 3 No.- 415V, 50 KVAR, 50Hz TP Power capacitor bank with built-
NOS
1
137500.00
137500.00
in/separate discharge resistor. 7 Nos.- 415V, 100 KVAR, 50Hz TP Power capacitor bank built-in/separate discharge resistor. 6 Nos.- 415V, 150 KVAR, 50Hz TP Power capacitor bank built-in/separate discharge resistor. 2 Nos.- 415V, 40 Amps. 50 Hz TP magnetic contactor with duty 3 No.- 415V, 80 Amps. 50 Hz TP magnetic contactor with duty 7 Nos.- 415V, 160 Amps. 50 Hz TP magnetic contactor with duty 6 Nos.- 415V, 250 Amps. 50 Hz TP magnetic contactor with duty 6 Nos.- 415V, 50 Amps HRC fuses with base 9 Nos.- 415V, 100 Amps HRC fuses with base 24 Nos.- 415V, 200 Amps HRC fuses with base 18 Nos.- 415V, 300 Amps HRC fuses with base 7.
8.
9.
with with AC3 AC3 AC3 AC3
H.T. CABLE WORK Supply, laying including installation, testing and commissioning of the following sizes 33KV XLPE insulated HT cable With HT Cable manufactured by M/S BRB/Paradise/super sign/Cables Ltd. In kutcha ground by cutting 45.70cm width x 91.40cm depth trench with necessary brick or tile protection and mending the damages good by refilling trench with proper compaction. In pucca road and tower top to tower bottom including G.I. pipe (National Tubes Ltd.) with necessary accessories by cutting 45.70cm width x 91.40cm depth trench mending the damages goods by earth filling providing 50mm thick compacted premix bituminous carpeting over one layer flat brick soling and 75mm thick compacted water bound macadam of khoa of brick. 3x240 sq. mm XLPE insulated HT cable. 3C-185 sq mm XLPE insulated HT cable. LT CABLE WORK Supply, laying including installation, testing and commissioning of the following sizes XLPE insulated and PVC sheathed (N2XY) cable and PVC insulated (BYA) cable manufactured by M/S BRB/paradise/super sign Cables Ltd. Cable electric low and medium tension laid in trenches trench excavation, embankments, required bricks/ tiles sand etc (Including pipe /conduit/duct is to be paid separarately) as specified voltage & current rating according to cable code BYA/NYY/BYM/A2×Y / NYSEYFG by to VDE standard. 4X(3X1C-400 sq mm(NYY) cable) with AS ECC-400 sq.mm BYA EARTHING Earthing the electrical installation with 38.10 mm (1.5") dia G.I. pipe (earth electrode) having 6.35 mm dia holes across the dia at 305 mm interval securedly bonded with 2 nos. of NO. 2 SWG HDBC earth lead with washer, nuts, bolts etc. sunk upto undermentioned depth and protection of earth lead by 20mm mm (3/4") dia G.I. pipe upto plinth level run at a depth of 609.6 mm (2 ft.) below G.L. upto main board to be earthed including necessary connecting copper sockets, bolts, nuts including additional vertical run of 12.7 mm dia G.I. pipe upto G.L. from 609.6 mm (2') depth
M M
M
300 100
12400.00 9576.24
3720000.00 957624.00
100
11256.75
1125675.00
with blind socket for water pouring facility etc. complete for maintaining earth resistance less than 1 ohm.
10.
11.
12.
13.
Depth of bottom of main electrode at 37338 mm. (122.5 ft) from GL & length of electrode 36576 mm. (120 ft).
set
10
780.00
7800.00
Construction of Earth inspection pit inside measurement 600mm x600mm with 250mm thick brick in cement morter (1:4) with 100mm thick RCC top slab (1:2:4) with 1% re-inforcement 450mm dia water sealed CI man hole cover with locking arrangement including necessary earth works,site filling and one brick flat soling 75mm thick (1:3:6) base concereate for making inlet channel & 12mm thick (1:2) cement plaster with neat finishing etc. all complete up to a depth of .75 meter.
set
10
970.00
97000.00
Suppling, Fiting and Fixing of single lighting arrester on the top of the building 1.22m long 12mm dia GI pipe and clamp with bolts and 3mm mounted air spike ,Top of the lighting arrester should be soldered and other fittings required etc.all complete in all respects as per directions of the E-I-C. Providing and drawing NO.2 SWG HDBC wire through 19mm (3/4") dia G.I. pipe including fitting, fixing the G.I. pipe in wall or column complete as required. The rate includes the supply & installation of a copper earthing block of size 30"x2.5"x3/4" (approx. as required) to be installed on sub-station wall using suitable insulator.
set
10
1310.00
13100.00
M
450
840
378000.00
3x240 sq.mm (FOR OUTDOOR USE)
set
4
12000.00
48000.00
3x240 sq.mm (FOR INDOOR USE)
set
7
12500.00
87500.00
No
01.
7454927.00
7454927.00
CABLE KITS Supply and fixing of heat shrink termination kit outdoor/indoor use complete with DIN lugs earth connection hardware and cable preparation kit (Indoor and Outdoor) at the point of cable termination for 33 KV, 3-core XLPE insulated and PVC sheathed & armoured cable of the following sizes (Made in GERMANY/USA/UK/FRANCE)
GENERATOR 600 KVA Diesel Generator Set Supply, installation, testing and commissioning of 600 KVA (Prime rating), 415V, 50 Hz, P.f. 0.8, 3-phase 4-wire diesel generator with foreign made acoustic canopy (sound level max. 75 dB @ 7m), including auto-changeover/auto-transfer (1000A) switch (ATS), battery, battery charger, earthing, fuel tank (min. 8 hrs. capacity) etc. complete as per design, specification, standard, and direction of. Engineer-in-charge. The Engine, Alternator, ATS, Control Panel etc. must be manufactured, assembled and tested in USA/ UK/ GERMANY/ FRANCE/ SWEDEN/JAPAN/ SPAIN. The diesel generator and its accessories must comply with the technical requirement of relevant local Authority. One number of manual changeover switches shall be supplied so that the continuity of the
service can be maintained in case of any disturbance in autochangeover switch. water cooled radiator with blower fan (water cooled engine only) with fan guards and fuel and injection pump, electrically operated with ammeter, lubricating oil pump, auto-speed governor air cleaner fuel and oil tank, automatic safely shut off for high water temperature, low oil pressure, over speed etc. water temperature gauge, oil pressure gauge tachometer, hour meter, start and stop switch, exhaust silencer, fly wheel coupling steel disc. Vibration isolator mounding steel base frame to support radiator, all complete in all respect as per direction of the Engineer-in-charge. Alternator having one single bearing brush less rotating type compound self exciting compound system drip-proof screen protected type with output voltage maintained within 1% with electronically operated automatic voltage regulator etc. all complete in all respect as per direction of the Engineer-incharge. Full set of tools necessary for maintenance of the complete generating set, foundation bolts with nuts starting DC batteries connecting leads with sockets battery first filling of lubricants and fuel etc. all complete in all respect as per direction of the Engineer-in–charge. Spare Requirement parts for 5 years: all filter-2 set, relar/timer-2 set, mccb(10-100A)- 30 pcs, sensor- 1set, all electronics card- 1set, etc. High speed computer- 1 set. necessary tools- Multimeter (voltcraft, m-3850), clamp meter266, mega-ohm meter-dy5103, infrared thermometers laser temperature meter, combination hand & machine box socket tools (300 pcs, etc), 14.
15.
The contractor shall be responsible for communicating with the local electric supply office and other authority viz. Chief Inspector of electric lisence board, Govt. of Bangladesh for their inspection/clearance and sanction of eclectic load, thereof, if any shall be included in the price of the item. The contractor shall submit the application for required load sanction and other paper formalities on behalf of the employer till the sub-station is commissioned and handed over to the employer. However, the security deposit money and HT metering panel installation charges for the proposed sub-station will be directly paid to local electric supply authority by the employer on submission of deposit slip & HT metering panel installation charges from the concern office of local electric supply authority. The contractor will not include in this item the amount of security deposit money and HT metering panel installation charges but all other incidental charges. Supply and fixing of following capacities multipurpose ABCE dry chemical powder stored pressure type with manometer system Fire Extinguisher suitable for repeated use complete with wall bracket, CO2 cartridge, easy refilling system etc. as per sample approved by the Engineer-in-charge. 6 Kg. capacity.
job 1
1
8500.00
8500.00
each
10
3500.00
35000.00
16.
Supply and installation of required no./quantity of approved type danger sign and rubber floor mat in the sub-station area as per direction of the Engineer.
S.N.
Description
17.
S/F Wiring complete for one light ,fan and bell point controlled by one switch using PVC non shd single core cable1.3/1.5rm (3/0.029) (iyal), holder, celing rose with PVC concealed conduit as sch spd. Including switch board final sub ckt, conduit heavy gauze and necessary consumables. 1.Light Point Connected with Generator for Corridor
job
c
Qnt.
unit
Unit rate (taka)
Amount (taka)
Nos
1128
866
976848.00
18.
Supply ,Fitting, Fixing of 5-15watt LED Light, holder/shed for Corridor with necessary fitting, Brand is as per direction of EIC
Nos
1128
330
372240.00
19.
Supply ,fitting, Fixing of Garden, Security Lighting , Stair Lighting ,Toilet Lighting and Others as per direction of EIC
Nos
400
330
132000.00
20.
Exhaust fan AC 230/220 volts single plase 50HZ complete with capacitor ,blade ,louver, rain guard etc 400 mm sewp .Brand GEC or direction of EIC
Nos
30
1200
36000.00
21.
Pole PC tubular 12 m height supply ,setting & erection in position all as spd and direction of EIC
Nos
5
25379.00
126895.00
22.
Three phage Meter Board with all excesories for Each Shop 15-200 amps
Nos
30
1369
41070.00
23.
Single phage Meter Board with all excesories for Each Shop 15-25 amps
Nos
1700
1369
2327300.00
24.
Dish Cable Point for the all floor DB point with specified dish line cable ,other arrangement ,connectors point and as per direction of the EIC
Nos
40
10000
400000.00
25.
PABX Cable,Connector, Control room equipment arrangement in DB point as per the direction of EIC
Nos
40
5000
200000.00
26.
Steel box made with 16 BG,MS/ plain sheet complete with hinged type door(single/double shutter) built-in type locking system with necessary arrangement for fixing of MCB/MCCBs by locking it’s knob out on the top cover is shutter grey hammer spray painting to the satisfaction of engineer in charge. All MCCB`s & ACB, From ABB, SACE Italy /USA / UK / Germany / Switzerland /France (Adjustable),
27
Steel box for MDB- size 1800mmx900 mmx600 mm
Nos
4
15000.00
60000.00
28
Steel box for EMDB- size 1800mmx900 mmx600 mm
Nos
4
15000.00
60000.00
29
Steel box for DB- size 900mmx600 mmx600 mm
Nos
40
7500.00
300000.00
30
Steel box for EDB- size 900mmx600 mmx600 mm
Nos
40
7500.00
300000.00
31
MK Steel box for SBD- size 4500mmx300 mmx125 mm
Nos
2000
5000.00
10000000.00
and
all
Main Distribution board (MDB) fabricated with 16BG,MS/ plain sheet ,FI bar and specified MCCBs/busbar etc including hammer paints & locking arrangement consisting of foreign MCB/MCCBs (Adjustable) 32
1000A
Nos
01
612000.00
612000.00
33
800A
Nos
04
106398.00
425592.00
34
300A
Nos
04
55900.00
223600.00
35
250A
Nos
08
33540.00
268320.00
36
225A
Nos
02
33540.00
67080.00
37
200A
Nos
16
33540.00
536640.00
38
160A
Nos
02
33540.00
67080.00
39
150A
Nos
02
9020.00
18040.00
40
125A
Nos
12
9020.00
108240.00
41
100A
Nos
10
11718.00
117180.00
42
70A
Nos
02
43
63A
Nos
20
669.00
13380.00
44
40A
Nos
30
669.00
20070.00
45
16-32A
Nos
4000
669.00
2676000.00
46
47 48
LT CABLE WORK Supply, laying including installation, testing and commissioning of the following sizes XLPE insulated and PVC sheathed (N2XY) cable and PVC insulated (BYA) cable manufactured by M/S BRB/paradise/supersign/others Cables Ltd. Cable electric low and medium tension laid in trenches trench excavation, embankments, required bricks/ tiles sand etc (Including pipe /conduit/duct is to be paid separarately) as specified voltage & current rating according to cablecode BYA/NYY/BYM/A2×Y/NYSEYFG by to VDE standard. 4X(2 X1C-300sq mm(NYY) cable) with AS ECC-300 sq.mm BYA 4X1c-400 sq mm(NYY) cable) with ECC-400 sq.mm BYA
M M
700 300
15350.00 19297.00
10745000.00 5819100.00
49 50
4X(2 X1C-630sq mm(NYY) cable) with AS ECC-400 sq.mm BYA 4X(1C-70 sq mm(NYY) cable) with AS ECC-70 sq.mm BYA
M M
50 50
31237.00 3739.00
1561850.00 186950.00
51
4X(1C-120 sq mm(NYY) cable) with AS ECC-70 sq.mm BYA
M
50
6188.00
309400.00
52
4X(1C-95 sq mm(NYY) cable) with AS ECC-70 sq.mm BYA
M
120
5001.00
600120.00
53
4X(2 X1C-185 sq mm(NYY) cable)with ECC-95 sq.mm BYA
M
60
9339.00
560340.00
54
4X50 sq mm(NYY) cable with ECC-25 sq.mm BYA
M
100
2871.00
287100.00
55
4X35 sq mm(NYY) cable with ECC-16 sq.mm BYA
M
100
2011.00
201100.00
56
4X25 sq mm(NYY) cable with ECC-16 sq.mm BYA
M
100
1568.00
156800.00
57
4X16 sq mm(NYY) cable with ECC-16 sq.mm BYA
M
1000
1114.00
1114000.00
58
4X10 sq mm(NYY) cable with ECC-10 sq.mm BYA
M
1000
1019.00
1019000.00
59
4X6 sq mm(NYY) cable with ECC-6 sq.mm BYA
M
3000
927.00
927.00
60
2X10 sq mm(NYY) cable with ECC-10 sq.mm BYA
M
1000
463.00
463.00
61
2X6 sq mm(NYY) cable with ECC-6 sq.mm BYA
M
3000
329.00
987000.00
62
2X4 sq mm(NYY) cable with ECC-4 sq.mm BYA
M
3000
263.00
789000.00
63
2X1C-2.5 sq mm(NYY) cable with ECC-2.5 sq.mm BYA
M
208.00
16265600.00
64.
S/F Wiring complete for three pin point using pvc non sheathed single core cable 2.5 rm (direct from SDB) with 3 pin 15/20 Amps socket as sch spd.
Nos
7820 0 50
525.00
26250.00
65.
S/F PVC conduit 20 mm dia as spd
Nos
5000
8.00
40000.00
66.
S/F -do-but 25 mm dia on spd
Nos
5000
6.00
30000.00
67.
Supply installation and tsting of end suction vertical discharge direct coupled centrifugal pumping set having capacity 150GPM against water head 60m at efficiency not less than 60% complete with motor electric AC 400volt ,50Hz, 3 phase HP 25 as specified model including base plate ,coupling guard, control panel with soft starter, main switch and switches connecting cables and testing /commissioning/trail run to the satisfaction of the EIC.The components shall be manufactured and tested in UK/USA/Germany/Japan/France.
Nos
03
223174.00
669513.00
300000.00
300000.00
68.
Supply and installation of submersible pumping set having capacity 150GPM against water head 70m at efficiency not less than 60% complete with motor electric AC 400volt ,50Hz, 3 phase HP 25 as specified model including base plate ,coupling guard, control panel with soft starter, main switch and switches connecting cables and testing /commissioning/ trail run to the satisfaction of the EIC.The components shall be manufactured and tested in UK/USA/Germany/Japan/France.
Nos
01
S.N.
Description
unit
Qnt.
Unit rate
amount
1.
ELEVATOR - PASSENGER (LIFT-01 & LIFT-05) Design, Supply ,Installation, testing & commissioning of Electric Traction type Fully automatic Passenger Elevator Having Stainless Steel mirror polish with Ac variable voltage &
set
02
2500000.00
5000000.00
variable frequency drive unit suitable for operation on 415 v,3 phase ,50 hz,Ac supply ,having speed of 1.5 MPS ,power operated glass central opening /two -panel side opening type car & landing doors, electro magnet brake system , operating panel with luminous buttons, overload warning indicator , battery operated alarm bell , emergency light , intercom suitable for hook up to AAI's EPABX, infrared ray sensing door protection for full height , reverse phase relay on controller , fire man's switch at ground floor , digital car positions indicator in car & at all floors with up/down direction , light fixtures ,ventilation fan , landing sill , main beam in shaft for machine , pit laddr etc complete with all accessories serving different floors in the lift shaft along with Automatic Rescue Device (ARD ) complete with dry maintenance free sealed batteries as required etc ., as per detailed specifications enclosed : manufactured, assembled and tested in USA/ UK/ GERMANY/ FRANCE/ SWEDEN/JAPAN/ SPAIN Passenger Lifts with 15 passenger /1000 kg capacity, 1.5 mps speed, ACVVVF control, Single Selective control Operation a). 7 stops ( Ground floor + 1st Flr-6th floor) all on same side, travel 25000 mm approx. b). Spare Requirement parts for 5 years: relar- 01 set, mccb (10-100A)- 01 set, sensor-01 set, electronics card -01 set,. necessary tools- Multimeter (voltcraft, m-3850), clamp meter266, mega-ohm meter-dy5103, infrared thermometers laser temperature meter, combination hand & machine box socket tools (300 pcs, etc),
2.
ELEVATOR - PASSENGER (LIFT-02& LIFT-04) Design, Supply ,Installation, testing & commissioning of Electric Traction type Fully automatic Passenger Elevator Having Stainless Steel mirror polish with Ac variable voltage & variable frequency drive unit suitable for operation on 415 v,3 phase ,50 hz,Ac supply ,having speed of 1.5 MPS ,power operated glass central opening /two -panel side opening type car & landing doors, electro magnet brake system , operating panel with luminous buttons, overload warning indicator , battery operated alarm bell , emergency light , intercom suitable for hook up to AAI's EPABX, infrared ray sensing door protection for full height , reverse phase relay on controller , fire man's switch at ground floor , digital car positions indicator in car & at all floors with up/down direction , light fixtures ,ventilation fan , landing sill , main beam in shaft for machine , pit laddr etc complete with all accessories serving different floors in the lift shaft along with Automatic Rescue Device (ARD ) complete with dry maintenance free sealed batteries as required etc ., as per detailed specifications enclosed : manufactured, assembled and tested in USA/ UK/ GERMANY/ FRANCE/ SWEDEN/JAPAN/ SPAIN
set
02
3100000.00
6200000.00
Passenger Lifts with 18 passenger /1200 kg capacity, 1.5 mps speed, ACVVVF control, Single Selective control Operation a). 7 stops ( Ground floor + 1st Flr-6th floor) all on same side, travel 25000 mm approx.
3.
ELEVATOR - PASSENGER (LIFT_-3 ,FIRE LIFT)
set
01
2500000.00
2500000.00
set
01
2500000.00
2500000.00
Design, Supply ,Installation, testing & commissioning of Electric Traction type Fully automatic Passenger Elevator Having Smoke proof Cabin & fire proof door with fire proof cables with Ac variable voltage & variable frequency drive unit suitable for operation on 415 v,3 phase ,50 hz,Ac supply ,having speed of 1.5 MPS ,power operated glass central opening /two -panel side opening type car & landing doors, electro magnet brake system , operating panel with luminous buttons, overload warning indicator , battery operated alarm bell , emergency light , intercom suitable for hook up to AAI's EPABX, infrared ray sensing door protection for full height , reverse phase relay on controller , fire man's switch at ground floor , digital car positions indicator in car & at all floors with up/down direction , light fixtures ,ventilation fan , landing sill , main beam in shaft for machine , pit laddr etc complete with all accessories serving different floors in the lift shaft along with Automatic Rescue Device (ARD ) complete with dry maintenance free sealed batteries as required etc ., as per detailed specifications enclosed : manufactured, assembled and tested in USA/ UK/ GERMANY/ FRANCE/ SWEDEN/JAPAN/ SPAIN Passenger Lifts with 18 passenger /1200 kg capacity, 1.5 mps speed, ACVVVF control, Single Selective control Operation a)
4.
7 stops (Ground floor + 1st Flr-6th floor) all on same side travel 25000 mm approx.
ELEVATOR - PASSENGER ( OBSERVATION ) Design, Supply ,Installation, testing & commissioning of Electric Traction type Fully automatic Passenger Elevator Having Observation sides Transparent glass with Ac variable voltage & variable frequency drive unit suitable for operation on 415 v,3 phase ,50 hz,Ac supply ,having speed of 1 MPS ,power operated glass central opening /two -panel side opening type car & landing doors, electro magnet brake system , operating panel with luminous buttons, overload warning indicator , battery operated alarm bell , emergency light , intercom suitable for hook up to AAI's EPABX, infrared ray sensing door protection for full height , reverse phase relay on controller , fire man's switch at ground floor , digital car positions indicator in car & at all floors with up/down direction , light fixtures ,ventilation fan , landing sill , main beam in shaft for machine , pit laddr etc complete with all accessories serving different floors in the lift shaft along with Automatic Rescue Device (ARD ) complete with dry maintenance free sealed batteries
as required etc ., as per detailed specifications enclosed : Passenger ( Observation) Lifts with 6 passenger /450 kg capacity, 1 mps speed, ACVVVF control, Single Selective control Operation
3.
a) 7 stops ( Ground floor + 1st Flr-6th floor) all on same side, travel 25000 mm approx. ESCALATOR Design, Supply ,Installation, testing & commissioning of Electric Traction type Fully automatic Passenger Escalator with fire proof cables with Ac variable voltage & variable frequency drive unit suitable for operation on 415 v,3 phase ,50 hz,Ac supply ,having speed of 1.5 MPS , operating panel with luminous buttons, overload warning indicator , battery operated alarm bell , emergency light , intercom suitable for hook up to AAI's EPABX, infrared ray sensing door protection for full height , reverse phase relay on controller , fire man's switch at ground floor , digital car positions indicator in car & at all floors with up/down direction , light fixtures ,ventilation fan , landing sill , main beam in shaft for machine , pit laddr etc complete with all accessories serving different floors in the lift shaft along with Automatic Rescue Device (ARD ) complete with dry maintenance free sealed batteries as required etc ., as per detailed specifications enclosed : manufactured, assembled and tested in USA/ UK/ GERMANY/ FRANCE/ SWEDEN/JAPAN/ SPAIN
set
TOTAL=
05
2200000.00
117113634.00TK
11000000.00