DO NOT SCALE THIS DRAWING . USE FIGURED DIMENSIONS THIS DRAWING IS COPYRIGHT. DO NOT REPRODUCE IT WITHOUT WRITTEN PERMISSION VERIFY ALL DIMENSIONS ON SITE BEFORE COMMENCING ANY WORK OR SHOP DRAWINGS
N
INFORM THE ARCHITECTS BEFORE ANY WORK STARTS IF THIS DRAWING EXCEEDS THE QUANTITIES IN ANY WAY
The Mall
Key: Demolished element
C
No.14
No.15
113
B
No.16
112
A
111
F
116
New stud partitions New masonry wall
No.13
Notes: (plant) Demolished elements described in brackets
Lightwell
Lightwell
C.1
Subject to further design development in conjuction with M&E & structural engineers
C.2
Subject to further design development in conjuction with M&E & structural engineers
Lightwell up
Corridor B5 Staff Bedroom B3
Staff Bedroom B7
Pool Base Household Stores/Plant B1
E 115
E 115
Kitchen/Prep + Wash-Up B2
Corridor B6
Staff Bathroom B4 riser 1c
Cupboard
Cupboard
Cupboard
Cupboard
Corridor B35
Linen B43 Storage
Corridor B34
ramp up
Storage
Staff Bathroom B8
Kitchen B9
Storage
Pantry B24
Store B17
Corridor B25
Storage
Store B10 Corridor B16
19 18 17 1615 14 13 12 Store below
riser 2a
Lift 2
Stair 2
Staff Lift 1
riser 1b
2
3 4
5 6
10
riser 1a
Staff Bathroom B41
114
Store B11
riser 3b
Staff Change (male) B32
WC B31
Family Lift
Staff Bathroom B38
Main Lift 3
Corridor B19
Corridor B26
Staff Change (female) B30
WC B29 Staff Bedroom B39
Staff Bedroom B40
Staff Bathroom B12 Store
Lobby B27
Porter B21
Refuse B46
Corridor B47
up
Corridor B14
up
Delivery
up
C.1
Porters Entrance
up
B60
B59
(plant)
up
B61
E
241007
Stair 3 terminated at lower ground floor level and staff dayroom added with link through to No.14. Main lift 3 doors repositioned to open into new lobby.
D
221007
Pre-application submission for listed building consent
C
121007
Core 13 & 15 ammended to client requirements
B
101007
Revisions following recent client changes and interior designers comments up to 031007
A
011007
Revisions following recent client changes and interior designers comments up to 260907
Rev.No.
Date
D 114
up up
C.2 vertical datum A
service riser 4 up
Secretary B28
(plant)
Stair 7 Hall
Lift 4
Staff Bedroom B13
Bathroom B20
Staff dayroom B22
(shower)
up
Store
Corridor B15
riser 3a
Laundry B45
D
Store B18
Store B37
Lift 1
Corridor B42
Lobby B23
Kitchen Stores B33
7 8 9
Corridor B36 Laundry B44
riser 2b
11
By
Amendment
Service Entrance
WELDON WALSHE
B48
ARCHITECTURE . INTERIOR DESIGN . HISTORIC BUILDING CONSERVATION 20 GROSVENOR PLACE LONDON SW1X 7HN t:0044 207 235 4100 f:0044 207 235 6678
Plant B58
Refuse & Recycling V5
Bedroom1 B49
E.D.F V1
Bedroom 2 B50
Corridor B55 Plant B57
Meters V8
Pump Room V13
Corridor V11
Refuse & Recycling V22
Boilers V16
PRELIMINARY
Corridor V19 Corridor V3 Water Tank V6
Bathroom B51
Water Tank V14
Water Tank V9
Water Tank V23
Pump Room V17
Corridor V12 Corridor B54
Plant B56
Fire Doors Plant B53
Plant B52
up
shower
Corridor V20
London Electricity Board V2
Water Tank V7
Chillers V15
Water Tank V10
Chillers V18
V4
Water Tank V24
13-16 Carlton House Terrace London SW1Y 5AH
Corridor V21
Basement Plan
C
113
B
112
A
111
F 3 2 1 0.5
scale:
1:100@a1
date:
24/08/07
1:200@a3
Carlton House Terrace
dwg no:
Scale @1:100 metres
0
116
4
5
as proposed
0
0.5
metres
1
2
3
4
5
CR866 101
drawn by: pm rev:
E